1600391 DWG 02OF12 HAZMAT.pdf

PDF 1 MB Posted

Attached to
REPAIR NAVY INFORMATION OPERATIONS DETACHMENT NAVSUBASE NEW LONDON, CT
Solicitation number
N40085-20-R-0033
Issued by

About this file

This document package includes a federal contract solicitation and related hazardous materials plans. The solicitation seeks repair and construction services for Building 106 at Naval Submarine Base New London in Connecticut. Work includes selective demolition, replacement of an exterior fire escape, HVAC replacement, roof replacement, fire protection repairs, basement structural repairs and waterproofing, plumbing repairs and replacements, bathroom renovations, loading dock repairs, structural repairs throughout the building and basement, hazardous material abatement, interior finish replacement, exterior masonry and concrete repairs, lightning protection, and electrical equipment replacements, redistribution and related work. The hazardous materials plans identify asbestos containing materials throughout the building basement, first and second floors.

View the file

Other files

File Type Posted
Amendment 0009.pdf PDF
PPI 45 DSCN4922 MSB nameplate.JPG JPG image
PPI 45 DSC 0104 MSB.JPG JPG image
Amendment 0008.pdf PDF
B106 Pictures.pdf PDF
Amendment 0007.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 04.pdf PDF
Amendment 03.pdf PDF
Attachment F - ALL CONTRACORs 5512_REV1.docx DOCX document
Attachment G - Contract General Requirement.docx DOCX document
Amendment 02.pdf PDF
Amendment 01.pdf PDF
1600391spec01of01-vol1.pdf PDF
Attachment B - SECNAV_ 5512_1.pdf PDF
1600391 DWG 06OF12 ENVELOPE.pdf PDF
Attachment E - Price Proposal Form.docx DOCX document
1600391 DWG 05OF12 ARCHITECTURE.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
1600391 DWG 03OF12 CIVIL.pdf PDF
1600391 DWG 10OF12 PLUMBING.pdf PDF
1600391 DWG 12OF12 ELECTRICAL.pdf PDF
1600391 DWG 04OF12 STRUCTURAL.pdf PDF
Attachment A - Pre-Proposal Inquiry Log Template.xlsx XLSX spreadsheet
1600391 DWG 09OF12 FIRE PROTECTION.pdf PDF
Attachment C - Construction Experience Project Data Sheet.docx DOCX document
1600391 DWG 11OF12 MECHANICAL.pdf PDF
1600391 DWG 08OF12 FIRE ALARM.pdf PDF
1600391 DWG 07OF12 LIFE SAFTEY.pdf PDF
1600391 DWG 01OF12 GENERAL.pdf PDF
Solicitation.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2 3 4 5 6 7 81

A

B

C

D

BASEMENT

STAIR 2

ELEV

(INACTIVE)

STAIR 3

0 2 4 8 16 32

N

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

SATISFACTORY TO

APPROVED

ACTIVITY

3/10/2020

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

D E

P A

R T

M E

N T

O

F

T

H E

V

Y N

A V

L

C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

S Y M D E S C R I P T I O N

D A T E

A P P R

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED - FOR OFFICIAL USE ONLY

UNCLASSIFIED - FOR OFFICIAL USE ONLY

U N C L A S S I F I E D

F O R

O F F I C I A L

U S E

O N L Y

SYMMES MAINI & McKEE ASSOCIATES

1000 Massachusetts Avenue

Cambridge, Massachusetts 02138

P: 617.547.5400 F: 617.648.4920

F I L E

N A M E

L A Y O U T

N A M E

P L O T T E D

U S E R

CFM/LEJ

EJA

APPROVED BY JOHNATHAN JOHNS

PM&EB SUPERVISOR WITH NAVAL

SUBASE, NEW LONDON, CT

N40085-20-R-0033

1600391

FAD

Y D o c u m e n t s R e v i t L o c a l C E N T R A L A r w a s s m e r r v t

As indicated

P M

P R

O

JE

C T

R M

-1

2:

R E

P A

IR

N

A V

Y

IN

F.

O

P E

R A

TI

O

N S

D E

TA

C

H M

E N

T, B

LD

G

D E

P A

R T

M E

T

V

Y

C r y s t a l

L a k e

R d

G r o t o n

C

T

D E P A R T M E N T

O F

T H E

N A V Y

C r y s t a l

L a k e

R d

G r o t o n

C T

HZ100

B A S E M E N T

H A Z M A T

S U R V E Y

P L A N

A D

12811747

SC CJS

SCALE: 1/8" = 1'-0"

BASEMENT HAZMAT PLAN

A1

I S S U E D

F O R

C O N S T R U C T I O N

ASBESTOS CONTAINING MATERIAL LOCATIONS

ACM-1 - MULTIPLE FLOOR TILE LAYERS NOW OVER 9" X 9" AND MASTIC

ACM-2 - PIPE FITTING INSULATION AND FITTINGS, VALES, SADDLES

ACM-3 - WINDOWS WITH GLAZE AND CAULK

OTHER ACM

- SUBSURFACE TRANSITE OR OTHER INSULATED PIPE

- FOUNDATION COATING

- TRANSITE - IN SWITCHGEAR, INFILLS, TRANSFORMERS

ACM-4 - GASKETS AND PIPE CONNECTIONS AND VALVES

ACM-5 - WINDOW CAULK AND GLAZE ENCAPSULATED IN BRICK

ACM-6 - ROOFING MATERIALS

ACM-7 - ELEVATOR BRAKES, HYDRAULIC FLUID, PCB FUSES

ACM-8 - FIRE DOORS

ACM-9 - DOOR CAULK

- EXTERIOR VAPOR BARRIER (ANY MATERIAL) AT FOUNDATION

SILLS AND INFILLS

ACM-7

ACM-2

ACM-4

ACM-9

ACM-8

UP

UP

UP

UP

DN

DN

DN

2 3 4 5 6 7 81

A

B

C

D

STAIR 1

STAIR 2

A

D

B

A

A

A

103A

A

119B

A

ELEV

(INACTIVE)

MACHINE

SHOP

STAIR 3

OFFICE

SWITCHGEAR

ROOM

103A

STORAGE

STORAGE

104A

MACHINE

SHOP

OFFICE

STORAGE

111B

OFFICE

OFFICE

OFFICE

107A

OFFICE

STORAGE

MECHANICAL

EQUIPMENT

ROOM

STORAGE

111A

LIBRARY

ENTRY &

STAIR

HALL

LOCKER

ROOM

MENS RM

109A

STORAGE

0 2 4 8 16 32

N

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

SATISFACTORY TO

APPROVED

ACTIVITY

3/10/2020

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

D E

P A

R T

M E

T

V

Y N

A V

C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

S Y M D E S C R I P T I O N

D A T E

A P P R

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED - FOR OFFICIAL USE ONLY

UNCLASSIFIED - FOR OFFICIAL USE ONLY

U N C L A S S I F I E D

F O R

O F F I C I A L

U S E

O N L Y

SYMMES MAINI & McKEE ASSOCIATES

1000 Massachusetts Avenue

Cambridge, Massachusetts 02138

P: 617.547.5400 F: 617.648.4920

F I L E

N A M E

L A Y O U T

N A M E

P L O T T E D

U S E R

CFM/LEJ

EJA

APPROVED BY JOHNATHAN JOHNS

PM&EB SUPERVISOR WITH NAVAL

SUBASE, NEW LONDON, CT

N40085-20-R-0033

1600391

FAD

Y D o c u m e n t s R e v i t L o c a l C E N T R A L A r w a s s m e r r v t

As indicated

P M

P R

O

JE

C T

R M

-1

2:

R E

P A

IR

N

A V

Y

IN

F.

O

P E

R A

TI

O

N S

D E

TA

C

H M

E N

T, B

LD

G

D E

P A

R T

M E

T

V y s t a l

L a k e

R d

G r o t o n

C

T

D E P A R T M E N T

O F

T H E

N A V Y

C r y s t a l

L a k e

R d

G r o t o n

C T

HZ101

S T

F L O O R

H A Z M A T

P L A N

A D

12811748

SC CJS

SCALE: 1/8" = 1'-0"

1ST FLOOR HAZMAT PLAN

A1

I S S U E D

F O R

C O N S T R U C T I O N

ASBESTOS CONTAINING MATERIAL LOCATIONS

ACM-1 - MULTIPLE FLOOR TILE LAYERS NOW OVER 9" X 9" AND MASTIC

ACM-2 - PIPE FITTING INSULATION AND FITTINGS, VALES, SADDLES

ACM-3 - WINDOWS WITH GLAZE AND CAULK

OTHER ACM

- SUBSURFACE TRANSITE OR OTHER INSULATED PIPE

- FOUNDATION COATING

- TRANSITE - IN SWITCHGEAR, INFILLS, TRANSFORMERS

ACM-4 - GASKETS AND PIPE CONNECTIONS AND VALVES

ACM-5 - WINDOW CAULK AND GLAZE ENCAPSULATED IN BRICK

ACM-6 - ROOFING MATERIALS

ACM-7 - ELEVATOR BRAKES, HYDRAULIC FLUID, PCB FUSES

ACM-8 - FIRE DOORS

ACM-9 - DOOR CAULK

- EXTERIOR VAPOR BARRIER (ANY MATERIAL) AT FOUNDATION

SILLS AND INFILLS

ACM-6

ACM-9

ACM-9

ACM-9

ACM-8

ACM-9 ACM-9 ACM-9 ACM-9

ACM-8

ACM-2

ACM-4

ACM-8

ACM-8

ACM-8

ACM-8

ACM-8

ACM-8

ACM-8

ACM-8 ACM-8

ACM-8

DN

2 3 4 5 6 7 81

A

B

C

D

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORRIDOR

OFFICE

OFFICE

OFFICE

CONFERENCE

ROOM

OFFICE

OFFICE

STAIR 1

STAIR 2

SUPPLY CHIEF

OFFICE

215A

IT

CLOSET

LIMIT OF WORK

D

D

D

D

D

D

D219

D215B

215A

D217

D216A

D218

214A

206A

D216

ELEV

(INACTIVE)

WOMENS

ROOM

STORAGE

MENS ROOM/

LOCKER

ROOM

STORAGE

OFFICE

MESS

LOUNGE

TRAINING

ROOM

215B

LOUNGE

OFFICE

0 2 4 8 16 32

N

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

SATISFACTORY TO

APPROVED

ACTIVITY

3/10/2020

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

D E

P A

R T

M E

T

V

Y N

A V

C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

S Y M D E S C R I P T I O N

D A T E

A P P R

DRAWFORM REVISION: 12 APRIL 2018

UNCLASSIFIED - FOR OFFICIAL USE ONLY

UNCLASSIFIED - FOR OFFICIAL USE ONLY

U N C L A S S I F I E D

F O R

O F F I C I A L

U S E

O N L Y

SYMMES MAINI & McKEE ASSOCIATES

1000 Massachusetts Avenue

Cambridge, Massachusetts 02138

P: 617.547.5400 F: 617.648.4920

F I L E

N A M E

L A Y O U T

N A M E

P L O T T E D

U S E R

CFM/LEJ

EJA

APPROVED BY JOHNATHAN JOHNS

PM&EB SUPERVISOR WITH NAVAL

SUBASE, NEW LONDON, CT

N40085-20-R-0033

1600391

FAD

Y D o c u m e n t s R e v i t L o c a l C E N T R A L A r w a s s m e r r v t

As indicated

P M

P R

O

JE

C T

R M

-1

2:

R E

P A

IR

N

A V

Y

IN

F.

O

P E

R A

TI

O

N S

D E

TA

C

H M

E N

T, B

LD

G

D E

P A

R T

M E

T

V y s t a l

L a k e

R d

G r o t o n

C

T

D E P A R T M E N T

O F

T H E

N A V Y

C r y s t a l

L a k e

R d

G r o t o n

C T

HZ102

N D

F L O O R

H A Z M A T

P L A N

A D

12811749

SC CJS

SCALE: 1/8" = 1'-0"

2ND FLOOR HAZMAT PLAN

A1

I S S U E D

F O R

C O N S T R U C T I O N

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-1

ACM-7

ACM-8

ACM-1

ACM-3 ACM-3 ACM-3 ACM-3 ACM-3 ACM-3

ACM-3 ACM-3ACM-3

ACM-3

ACM-3

ACM-3

ACM-3

ACM-9

ACM-9

ACM-8

ACM-2

ACM-4

ASBESTOS CONTAINING MATERIAL LOCATIONS

ACM-1 - MULTIPLE FLOOR TILE LAYERS NOW OVER 9" X 9" AND MASTIC

ACM-2 - PIPE FITTING INSULATION AND FITTINGS, VALES, SADDLES

ACM-3 - WINDOWS WITH GLAZE AND CAULK

OTHER ACM

- SUBSURFACE TRANSITE OR OTHER INSULATED PIPE

- FOUNDATION COATING

- TRANSITE - IN SWITCHGEAR, INFILLS, TRANSFORMERS

ACM-4 - GASKETS AND PIPE CONNECTIONS AND VALVES

ACM-5 - WINDOW CAULK AND GLAZE ENCAPSULATED IN BRICK

ACM-6 - ROOFING MATERIALS

ACM-7 - ELEVATOR BRAKES, HYDRAULIC FLUID, PCB FUSES

ACM-8 - FIRE DOORS

ACM-9 - DOOR CAULK

- EXTERIOR VAPOR BARRIER (ANY MATERIAL) AT FOUNDATION

SILLS AND INFILLS

HZ100 - BASEMENT HAZMAT SURVEY PLAN
HZ101 - 1ST FLOOR HAZMAT PLAN
HZ102 - 2ND FLOOR HAZMAT PLAN

2020-04-04T08:45:18-0400

2020-04-04T08:45:40-0400

2020-04-04T08:45:44-0400

2020-04-05T08:18:09-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-04-05T08:18:31-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-04-05T08:18:31-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-04-05T08:27:14-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-04-05T08:27:42-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2020-04-05T08:27:43-0400
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.

File details come from the government source that posted it. Updated .