This document package includes construction drawings and specifications for interpretive exhibit fabrication and installation services. The drawings show details for immersive audiovisual displays and physical structures within the Hoover Dam Visitor Center exhibit level. The related federal contract opportunity is solicitation number 140R3022R0014 for interpretive exhibit fabrication and installation services issued by the Department of the Interior Bureau of Reclamation. The solicitation seeks a contractor to fabricate and install the exhibits depicted in the drawings to support telling the story of Hoover Dam and its history.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X3.120
3.1.2 IMMERSIVE AV - DETAIL
241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111
LGAarchitecture.com
A
LW
AY
S
T H
IN
K
S A
FE
TY
C
AD
F
IL
EN
AM
E
C
AD
S
YS
TE
M
D
C
B
A
D
C
B
A
U .S
. D
EP
AR
TM
EN
T
O F
TH
E
IN
TE
R
IO
R
BU
R
EA
U O
F R
EC
LA
M
AT
IO
N
Managing Water in the West
H O
O V
E R
D A
M V
IS
IT
O R
C E
N
TE
R
E X
H
IB
IT
L
E V
E L
P R
O
JE
C T
OFFICE
AR
C
H
IC
AD
BI
M cl ou d:
b im .lg ai nc
.c om
BI
M cl ou d
Ba si c fo r A R
C H
IC
AD
5/
H oo ve r D am
V is ito r C en te r E xh ib it
Le ve l
DESIGNED
DRAWN
CHECKED
TECH. APPR.
APPROVED
ADMIN APPROVAL -
All dimensions and on-site conditions are to be verified by the Subcontractors before starting their work.
Report any discrepancies to the General Contractor.
Date of Issue: 09/06/22
M. BELANGER
T. STOTT
043820001PROJECT NO.:
(consultant)
(stamp)
B U
R E
A U
O F
R E
C
LA
M
AT
IO
N
B O
U
LD
E R
C
IT
Y N
V
All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.
RECLAMATION
302 – 1930 Pandora Street Vancouver, BC V5L 0C7
604-669-7044
ALDRICHPEARS.com
1100 – 99 Wyse Road Dartmouth, NS B3A 4S5
902-700-9140
M. BELANGER
3.1.2 PASSAGEWAY IMMERSIVE AV - OUTER WALL
Scale: 3/8" = 1'-0"5
Structural steel beams above - refer to architectural drawings
Concrete floor at top of entry ramp
Lumber hoarding and bracing
Handrail covers division between monitors
Safety rail
Footrail
Supporting cross beam
Header rail
Monitor
Light box
Faux rockwork
Supporting cross members Floor planking Lighting below to show between loosely fitted planks
Lighting above to show between loose fitted planksOverhead planks
9' -2
" C
LE
A R
6" 7'
-9
3.1.1-1
WD-02
WD-01
WD-03
3.1.2 PASSAGEWAY IMMERSIVE AV - OUTER WALL
Scale: 3/8" = 1'-0"4
Structural steel beams above - refer to architectural drawings
Supporting cross members Floor planking Lighting below to show between loosely fitted planks
Joe McGee basket
Vertical lumber
Lighting above to show between loose fitted planks
Overhead planks
Cross beam
9' -2
" C
LE
A R
6" 7'
-9
WD-01
WD-01
WD-03
NOTE: There is a dynamite plunger, mechanical interactive in exhibit 4.1.2 Pre-Construction / Diversion Tunnels.
When the plunger is depressed an explosion effect will be seen, heard and felt in 3.1.2 Passageway Immersive AV.
3.1.2 PASSAGEWAY IMMERSIVE AV - INNER WALL
Scale: 3/8" = 1'-0"1
Structural steel beams above - refer to architectural drawings
9' -2
" C
LE
A R
3.1.1-A1
Supporting cross members Floor planking Lighting below to show between loosely fitted planks
6"
Lighting above to show between loose fitted planks
Cross beam
Overhead planks
Joe McGee basket
Monitor
Lumber kick
Horizontal lumber
7' -9
Vertical lumber
WD-01
WD-01
3.1.2 PASSAGEWAY IMMERSIVE AV - CROSS SECTION
Scale: 3/8" = 1'-0"2
Structural steel beams above - refer to architectural drawings
8'-2" 11"
WD-01
WD-01
WD-03
Monitor Monitor
X3.120
3.1.2 HANDRAIL DETAIL
Scale: 3/4" = 1'-0"3
Exterior wall
Vertical steel beam
Vertical lumber
Handrail
NOTE: handrail to be set as close to steel beams as possible to maximize passageway width.
Handrail filler
NOTE: filler to be set as close to monitors as possible.
Bezel must be hidden from visitors view.
FF-01
REV 01
| X3.120-3.1 Passage Way Experience |
| 5/X3.10 |
| 5/X3.11 |
| 5/X3.08 |
| 1/X3.20 |