Att_8_-_Supplemental_Information_1_0001.pdf

PDF 1 MB Posted

Attached to
INTERPRETIVE EXHIBIT FABRICATION & INSTALLATION Federal contract opportunity
Solicitation number
140R3022R0014
Issued by
Department of the Interior Bureau of Reclamation

About this file

This document package includes specifications and drawings for an interpretive exhibit at the Hoover Dam Visitor Center. The lighting design calls for various track lighting, downlights, edge lighting and accent lighting to illuminate exhibit cases, murals, artifacts and interactive elements throughout the space. Detailed drawings show lighting layouts and locations for each area, as well as specifications for the different lighting fixture types and control requirements. The associated federal contract opportunity is for interpretive exhibit fabrication and installation services for the Bureau of Reclamation at the Hoover Dam Visitor Center. The solicitation number and opportunity details are provided but no additional information is given on response dates, pricing terms or other contract requirements.

View the file

Other files for this federal contract opportunity

Other files attached to INTERPRETIVE EXHIBIT FABRICATION & INSTALLATION, newest first.
File Type Posted
Sol_140R3022R0014_Amd_0004.pdf PDF
140R3022R0014_-_Questions_and_Responses_-Amd_No__0004_0004.pdf PDF
Revised_Drawing_-_X4_120-4_1_2_Pre-Construction_Diversion_Tunnels_0003.pdf PDF
Revised_Drawing_-_X4_280-4_2_8_Rubble_wall_and_dam_wall_0003.pdf PDF
Sol_140R3022R0014_Amd_0003.pdf PDF
Revised_Drawing_-_X3_120-3_1_Passage_Way_Experience_0003.pdf PDF
Revised_-_03_02_Digital_Media_Production_4_2_4_Construction_Model_Interactive_2022_09_06_0003.pdf PDF
Revised_-_X0_500-Materials___Finishes_0003.pdf PDF
Revised_-_03_02_Digital_Media_Production_0_1_Audio_Description_2022_09_06_0003.pdf PDF
Revised_-_HOOVER_SECTION_03_02_00_DIGITAL_MEDIA_-_PRODUCTION_0003.pdf PDF
Revised_03_01_AV_Production_Assets_2022_09_06_0003.pdf PDF
Revised_-_03_02_Digital_Media_Production_4_1_3_Design_and_Engineering_2022_09_06_0003.pdf PDF
Sol_140R3022R0014_Amd_0002.pdf PDF
140R3022R0014_-_Sign_in_Sheet_0001.pdf PDF
Sol_140R3022R0014_Amd_0001.pdf PDF
Site_Visit_PowerPoint__-_Interpretive_Exhibit_Fabrication_and_Installation_Services_0001.pdf PDF
HOOVER_SECTION_06_06_00_REPLICAS_revised_2022-08-19_0001.pdf PDF
140R3022R0014_-_Questions_and_Responses_-Amd_No__0001_0001.pdf PDF
Revised_Section_E_-_Pg_E-14-_8-23-2022_0001.pdf PDF
Att_7_-_Architectural_Drawings_-_VC_Renovation_Project_0001.pdf PDF
Att_9_-_Supplemental_Information_2_0001.pdf PDF
Attachment_3C_-_Production_Reference_Document_-_Pgs_289-370.pdf PDF
Sol_140R3022R0014.pdf PDF
Attachment_2_-_Design_Drawings.pdf PDF
Attachment_1_-_Specifications_-_Final_6-2022.pdf PDF
Attachment_3D_-_Production_Reference_Document_-_Pgs_371-431.pdf PDF
_Solicitation_No__140R3022R0014_-_Interpretive_Exhibit_Fabrication_and_Installation.pdf PDF
Attachment_4_-_Wage_Determinations_No_2015-5593_Rev_21__6-27-2022.pdf PDF
Attachment_6_-_Past_Performance_Questionnaire.pdf PDF
Attachment_3B_-_Production_Reference_Document_-_Pgs_190-288.pdf PDF
Attachment_3A_-_Production_Reference_Document_-_Pgs_1-189.pdf PDF
Attachment_5_-_DI-137_Release_of_Claims.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIGHTING INTEGRATOR

1.

2.

3.

4.

5.

6.

The exhibit lighting and controls shall be installed, commissioned and programmed by a Lighting Integrator. The Lighting Integrator shall be included by all bidding contractors.

Lighting Integrator shall be able to supply and program a complete working system based on the design requirements, including all necessary cables, power and data distribution, power supplies, and lighting accessories.

Lighting Integrator shall provide a professional Lighting Programmer with minimum five years experience who is an experienced in programming the specified lighting control system.

Lighting Integrator shall provide an On-site Aim and Focus crew. Aim and focus crew shall be experienced with the specified lighting fixtures.

Lighting Integrator shall coordinate with the Exhibit Designer and the Lighting Designer to determine the required number of days on site to complete the programming and focusing requirements.

The Lighting Integrator shall have minimum three years experience in exhibits, themed attractions and highend themed retail including proficiency with:

- All manufactures’ lighting equipment as specified

- Installing and controlling theatrical lighting

- Programming software and console based lighting controls systems

- Exhibit lighting focus and aiming

- Low voltage wiring management and termination,

- Implementing DMX and Ethernet based data distribution systems

- Implementing lighting industry control protocols:

DMX, sACN, UDP, ArtNET, KiNet, RDM, 0-10V, SMPTE, SPI, MIDI, and ETCNet.

DMX512 REFERENCE

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

All wiring must be in a continuous run and daisy-chained. No “Tees” are permitted. Star wiring is only allowed in conjunction with an opto-splitter.

Cable shield may be grounded at one end only, at the control source.

Maximum cable length is 1,500 ft when used for DMX only. Maximum cable length for systems incorporating RDM is 1000 ft due to timing constraints.

Receiving devices have male connectors, transmitters have female (for XLR cable).

Wire must be Cat5e, Cat6, or Belden 9829, 9842 - specific installation and site parameters shall dictate performance for permanently installed cables. Electrical Engineer and or General Contractor shall flag any site conditions which may effect data signal integrity.

Suggested Wiring Practices:

- Do not run data signals next to or in the same conduit as high power sources. If necessary to be near these sources, cross them over at 90 degrees or keep as much parallel distance between them as possible.

- Use IDCs for all Category 5 cable applications.

- Run in grounded metal conduit when there may be concern from nearby high power devices and/or situations where the structure of the cable may be compromised.

- Plenum cable in plenum applications and also where physical damage may be a concern and conduit is not practical. Sheilded twisted pair (STP) Category wire is required when conduit is not practical.

- Cables should be protected against physical damage along their entire length and may include conduit, trunking, or raceways.

- Stranded cable is preferred.

The last DMX device on the line must be terminated with a termination switch or resistor with a value of 100 to 120 ohms between pins: Data+ and Data-.

RJ45 connectors may be used with Cat5e / Cat6 cable, for permanent wiring. RJ45 connectors and Cat5e / Cat6 cable should not be used to connect portable equipment.

Cat5e / Cat6: UTP cable may be used inside metal conduit. Use STP when installed outside of conduit.

Cat5e / Cat6: Wires 4 and 5 are commonly used in non-DMX equipment to carry power-over-Ethernet. Best practice for DMX only wiring installers is to cap and turn back this pair to avoid accidental damage to equipment.

Cat5e / Cat6: All RJ45 couplers shall be wired to Esta Standard T568B.

Cat5e / Cat6: Wires 7 and 8 shall both be connected even

DMX Wiring Connections for CAT5e, CAT6 Cabling

Wire Colour Pin Number Function Equivalent XLR Pin White Orange 1 Data + 3

Orange 2 Data - 2 White Green 3 Optional Data + 5

Blue 4 Unassigned - White Blue 5 Unassigned -

Green 6 Optional Data - 4 White Brown 7 Common 1

Brown 8 Common 1

DMX Wiring for XLR Connections

XLR Pin Standard RS422/485 Wire 1 Shield / Common 2 Data - 3 Data + 4 Optional Data - 5 Optional Data +

Wire color is manufacturer specific.

Use connector to determine pin number for each wire.

SUPPLIER NOTES - LIGHTING

1.

2.

3.

4.

Supplier to provide product based on specifications detailed in the attached Equipment Schedule(s). Any cutsheets or model numbers provided by the Designer are for reference only. Any discrepancy between Equipment Schedule and reference materials issued shall be brought to the attention of the Designer and Architect.

Shop Drawings are required for review prior to ordering equipment.

All lighitng equipment to be supplied with specified accessories, including lamps, power supplies, mounts, etc.

Final finish of equipment colours to be approved in writing by Architect and Designer.

DOCUMENT NOTES

1.

2.

3.

4.

5.

6.

All drawings represent design intent of visual concepts. Designer will not assume responsibility for structural or electrical engineering.

All drawings and the associated design intent indicated thereon or represented thereby are owned by & remain the property of Eos Lightmedia; they are developed for use on and in connection with the specified project.

Eos Lightmedia defines Lighting as all equipment related to the lighitng system, including networking equipment and associated controls.

Eos Lightmedia defines AV as all equipment related to the audio, visual and interactive systems, including networking equipment and associated controls.

Written dimensions on drawings shall have authority over scaled measurements. Contractors and manufacturers shall verify & be responsible for all dimensions and conditions on the job and inform the Designer and Architect of all variations from drawings prior to performing the work.

In the absence of written dimensions, the architectural plans, reflected ceiling plans, sections and details shall indicate the proper locations of equipment and devices, if applicable. Exact locations to be verified with field conditions and confirmed with Owner, Architect, Engineer and Designer prior to final installation.

CONTRACTOR'S RESPONSIBILITIES - LIGHTING

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

Contractor shall supply and install a complete, working lighting system.

Contractor is responsible for confirming final counts of all equipment and accessories.

Contractor shall be responsible for verifying mounting compatibility and plenum clearance of all lighting fixtures. Contractor shall notify Owner and Architect of any conflicts with structure, HVAC, or plumbing prior to the ordering of the equipment in question.

Contractor shall verify that all lighting equipment —in its intended application on this project—complies with all applicable national & local codes, ordinances, regulations and jurisdictions prior to ordering any equipment.

Contractor will provide an additional 10% replacement lamps of each lamp type (minimum two [2] of each lamp type specified) to the Owner upon completion of the job.

Contractor to provide programmer with 5 years minimum experience programming the specified lighting controller. Experience must include multiple cue lists, event list programming, LED color mixing, DMX and lighting networks.

Contractor shall supply manufacturer's transformer of proper capacity. Remote Transformer or Power Supply shall be in nearby accessible, concealed-from-view location with recommended ventilation.

Contractor shall be responsible for all materials required to ensure a safe and proper pendant installation. Fixture or Track shall be mounted to structure in a manner recommended by the manufacturer and so as not to compromise the integrity of the structure: Includes all material for rigid hanging of fixtures and track to all local seismic standards. Rigid hanging preferred unless otherwise noted.

Contractor shall be responsible for final targeting of aimable/adjustable luminaires under the observation, and according to the recommendations of the Lighting Designer. As aiming and adjusting is completed, crews are responsible for tightening all locking set screws, handles, bolts, etc. to insure that fixture focus is permanently maintained.

Contractor shall focus and adjust designated luminaire(s), after dark, at a time mutually agreeable to Contractor, Lighting Designer and Owner. Adjustments shall be made in accordance with the Lighting Designer's stated intent, under his/her observations.

Contractor shall furnish all ladders, scaffolds, lifts, etc. required for fixture aiming and adjusting.

Contractor shall include all costs associated with aiming and focusing in the base bid.

Light leaks between ceiling trims of recessed lighting equipment and the ceiling plane will NOT be tolerated. If fixture is used in partially transparent ceiling, light leaks above the ceiling line will NOT be tolerated.

Reflectors, reflector cones and visible trim of all lighting fixtures shall not be installed until completion of plastering, ceiling tile work, painting and general cleanup.

Junction boxes and conduit that is used to wire fixtures and that is open to view shall be painted to match adjacent structure.

Common neutral for branch circuits will not be accepted.

At the time of acceptance by the Owner, all lighting fixtures shall have been thoroughly cleaned with materials and methods recommended by the manufacturers, all broken parts shall have been replaced, and all lamps shall be operative.

All life-safety systems, procurment, installation and related design by others.

All lighting equipment shall be security mounted to a dedicated secondary structure. No lighting equipment, supports, rigging or hanging positions shall be suspended from, mounted to, or be structurally tied to the same unistrut, allthread, or other secondary structural elements as any other equipment, including but not limited to HVAC, Security, or Fire Safety.

OWNERS' RESPONSIBILITIES

1. It is the responsibility of the owner to perform proper and regular maintenance in order to ensure expected performance of all equipment. Neither the Architect, Engineer nor Designer can be held responsible or liable for improper service and maintenance of systems.

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

TE

R

E X

H

IB

IT

L

E V

E L

P R

O

JE

C T

NOTES

OFFICE

LX 002

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

All dimensions and on-site conditions are to be verified by the Subcontractors before starting their work.

Report any discrepancies to the General Contractor.

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

Designed

Date of Issue: 04/12/22

BID

SET

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

L1

INSTRUMENT TYPE

UNIT ID

INSTRUMENT SYMBOL

LIGHTING TRACK

COVE

PIPE/ TRUSS

(BLUE)

(BLACK)

(BLACK)

DATA - CAT5e / CAT6

HDMI

SERIAL

USB

AUDIO

120VAC NON-DIM

DMX - CAT5e / CAT6

POWER + DATA LEADER / JUMPER

120VAC DIMMED

5 - 48VDC

SYMBOL LEGEND

ETHERNET COMPUTER NETWORK:

CAT5e TERMINATED IN J-BOX

W/ FEMALE RJ45 TIA-568B

DMX LIGHTING NETWORK:

CAT5e TERMINATED IN J-BOX

W/ FEMALE RJ45 TIA-568B

HD-BASE-T VIDEO NETWORK

CAT5e TERMINATED IN J-BOX

W/ FEMALE RJ45 TIA-568B

NETWORK CONNECTION

CAT5e TERMINATED IN J-BOX

W/ FEMALE RJ45 TIA-568B

INDICATES DEVICE IN FLOOR MOUNTED

JUNCTION BOX

DUPLEX RECEPTACLE 120VAC NEMA5-15R

DEVICE REQUIRES DC POWER AS NOTED

120VAC

12VDC

K

D

V

A

L

E

AUDIO NETWORK

CAT5e TERMINATED IN J-BOX

W/ FEMALE RJ45 TIA-568B

KINET LIGHTING NETWORK

CAT5e TERMINATED IN J-BOX

W/ FEMALE RJ45 TIA-568B

eDMX / ARTNET LIGHTING NETWORK CAT5e TERMINATED IN J-BOX

W/ FEMALE RJ45 TIA-568B

DEVICE REQUIRES AC POWER AS NOTED

INDICATES DEVICE IN CEILING MOUNTED

JUNCTION BOX

QUAD RECEPTACLE 120VAC NEMA5-15R

RISER LINE LEGEND LIGHTING LAYOUT LINE LEGEND

INSTRUMENT TYPE

INSTRUMENT SYMBOL

L2

01 ZONE NUMBER

TRACK UNIT NUMBER

TRACK SYMBOL

INSTRUMENT SYMBOL

CP02

PHAROS

LCP2

DEVICE TYPE

DEVICE NOTES

INSTRUMENT SYMBOL

COPY AND PASTE LEGANDS FOR VIEWPORTS AS REQUIRED FOR YOUR PROJECT

CREATE NEW LEGENDS AS REQUIRED FOLLOWING THE FORMAT BELOW

UNIT NUMBER

INSTRUMENT SYMBOL

D03

12" AFF

D

MODIFING NOTE

LABEL LEGEND

RGBW FLOODLIGHT LUMINAIRE

RGBW LINEAR GRAZE LUMINAIRE

SURFACE MOUNTED DOWNLIGHT

RECESSED DOWNLIGHT

LIGHTING DEVICE LEGEND

MONITOR - LARGE

LOUDSPEAKER

SUBWOOFER

CAMERA

WIRELESS ACCESSPOINT (WAP)

VIDEO PROJECTOR

AUDIO / VIDEO / INTERACTIVE DEVICE LEGEND

12'

SCOPE DEFINITIONS

SCOPE DEFINITIONS

DESIGN IDENTIFY SYSTEM REQUIREMENTS & PRODUCE DRAWINGS FOR DESCRIBING

SYSTEM INTENT

SPECIFY PROVIDE CUT SHEETS AND PRODUCT INFORMATION FOR SYSTEM ITEM

SUPPLY PURCHASE AND SHIP SYSTEM ITEM TO INSTALLATION SITE

INSTALL PHYSICALLY INSTALL SYSTEM ITEM INTO PERMANENT LOCATION ON SITE

TERMINATE PHYSICAL CONNECTION OF ALL CABLES, DUPLEX RECEPTACLES, POWER FEEDS,

ETC.

COMMISSION ENSURE EQUIPMENT AND NETWORK SYSTEM OPERATES AS INTENDED AND IS

READY FOR CONTENT AND CREATIVE PROGRAMMING

WLNP - DIVISION OF LABOUR: FEATURE LIGHTING AND AV FOR INTERPRETIVE SPACE

ITEM OF WORK DESCRIPTION BASE BUILDING ELECTRICAL CONTRACTOR LIGHTING & AV DESIGNER / INTEGRATOR ENGINEERING / ARCHITECTURAL TEAMS

ELECTRICAL INFRASTRUCTURE CONDUIT, WIRE, AND BOXES FOR

ALL AV AND LIGHTING SYSTEMS

SUPPLY, INSTALL, TERMINATE AND

COMMISSION

- DESIGN AND SPECIFY

AC POWER FOR ALL AV, DIMMER

AND CONTROL SYSTEMS

SUPPLY, INSTALL, TERMINATE AND

COMMISSION

- DESIGN AND SPECIFY

DATA, SIGNAL AND CONTROL

INFRASTRUCTURE

CONDUIT, WIRE, AND BOXES FOR

ALL AV AND LIGHTING SYSTEMS

SUPPLY, INSTALL, TERMINATE AND

COMMISSION

- DESIGN AND SPECIFY

AV SIGNAL AND NETWORK

CABLES, DMX DATA AND

SPECIALTY LIGHTING CONTROL

WIRING

SUPPLY, INSTALL, TERMINATE AND

COMMISSION:

ALL WIRING INCLUDING LABELS FROM

CONTROL RACKS TO ENCLOSURES AND J-

BOXES IN THE FIELD. TERMINATE AND LABEL

AV AND LX DATA AS FEAMLE RJ45 IN THE

FILED AND PANEL IN CONTROL RACK.

SUPPLY, INSTALL, TERMINATE AND

COMMISSION:

ALL DATA WIRING BETWEEN DEVICES WITHIN

CONTROL RACKS AND ENCLOSURES. ALL DATA

BETWEEN DEVICES IN THE FIELD.

DESIGN AND SPECIFY

BASE BUILDING AND BOH

LIGHTING

AMBIENT AND TASK LIGHTING

FOR ARCHITECTURAL AND STAFF

USE

SUPPLY, INSTALL, TERMINATE AND

COMMISSION

REVIEW SPEC DESIGN AND SPECIFY

CENTRAL CONTROL SYSTEM BMS SUPPLY, INSTALL, TERMINATE AND

COMMISSION

- DESIGN AND SPECIFY

EXHIBIT AND INTERPRETIVE

LIGHTING AND AV CONTROLS

LIGHTING AND AV CONTROL AND

PLAYBACK EQUIPMENT

- DESIGN, SPECIFY, SUPPLY, INSTALL,

TERMINATE AND COMMISSION

REVIEW SPEC FOR CODE COMPLIANCE

EXHIBIT AND INTERPRETIVE

FEATURE LIGHTING

THEATRICAL LIGHTING, MUSEUM

TRACK SYSTEM AND INTEGRATED

EXHIBIT LIGHTING

INSTALL, TERMINATE AND COMMISSION:

ALL TRACK, RECESSED AND ALL LIGHTING

REQUIRING HARDWIRED 120VAC

CONNECTIONS

DESIGN, SPECIFY, SUPPLY, INSTALL,

TERMINATE AND COMMISSION:

INSTALLATION OF ALL TRACK HEADS,

THEATRICAL LUMINAIRES AND INTEGRATED

LOW VOLTAGE LIGHTING. INSTALLATION OF

ALL LIGHTING WITH U-GROUND CONNECTION

TO 120VAC

REVIEW SPEC FOR CODE COMPLIANCE

EXHIBIT AND INTERPRETIVE AV AUDIO, VIDEO, INTERACTIVE

EXHIBIT EQUIPMENT

- DESIGN, SPECIFY, SUPPLY, INSTALL,

TERMINATE AND COMMISSION

REVIEW SPEC FOR CODE COMPLIANCE

BUTTON STATIONS LIGHTING AND SYSTEM

CONTROLS FOR BOH AND

ARCHITECTURAL

SUPPLY, INSTALL, TERMINATE AND

COMMISSION

- DESIGN AND SPECIFY

TABLET CONTROL EQUIPMENT

AND INTERFACE

EXHIBIT SPECIFIC USER CONTROL

INTERFACE

- DESIGN, SPECIFY, SUPPLY, INSTALL,

TERMINATE AND COMMISSION

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

H

IB

IT

L

E V

E L

P R

O

JE

C T

LEGENDS AND DIVISION

OF RESPONSIBILITIES

OFFICE

LX 003

DESIGNED

DRAWN

CHECKED

TECH. APPR.

Report any discrepancies to the General Contractor.

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

Designed

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

Date of Issue: 04/12/22

BID

SET

STAIR

S5

ELEVATOR

E4

WOMEN

ELECTRICAL

JANITOR

LOBBY

GALLERY

RECEPTION

U P

DN

6" AFF

0"

AFF

0" AFF

UP

U P

SLOPE

2.75%

U P

A

VESTIBULE

MEN

FOYER

EXHIBITEXHIBIT

ENTRY

LX04

LX04

LX04

LX04

LX04

LX04

LX04

LX04

LX10

LX10

LX10

LX10

LX10

LX03

LX03

LX03

LX03

LX03LX03

HOOVER DAM VISITOR CENTER - EXHIBIT LIGHTING LAYOUT - NORTH

Scale: 1:501

5 x TYPE LX04 ON EACH

TRACK. TRACKS MOUNTED

VERTICALLY BEHIND BEAM

(TYPICAL)

SEE AV PACKAGE FOR TYPE

LX13 IN AREA.

BACKLIT LIGHT BOX

INTERACTIVE.

TYPE LXO3 MOUNTED BELOW

FLOOR PLANKS. SEE DRAWING

#4 ON LX200 FOR DETAILS

TYPE LXO3 MOUNTED ABOVE

CEILING PLANKS. SEE

DRAWING #4 ON LX200 FOR

DETAILS

TYPE LX10 TO REPLACE BASE

BUILDING LIGHTING USING

THE SAME BACKBOXES ONCE

THE EXHIBIT IS INSTALLED.

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

H

IB

IT

L

E V

E L

P R

O

JE

C T

EXHIBIT LIGHTING

DESIGN - NORTH

OFFICE

LX 100

DESIGNED

DRAWN

CHECKED

TECH. APPR.

Report any discrepancies to the General Contractor.

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

Designed

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

Date of Issue: 04/12/22

EXHIBIT

0" AFF

0"

AFF

6" AFF

0" AFF

DN

SLOPE4.75%

LX04

LX04

LX07B

LX07B

LX07B

LX07B

LX05

LX09

LX05

LX06

LX08B

LX08B

LX08C

LX08C

LX04

LX04

LX04

LX04

LX04

LX04 LX04

LX04

LX04

LX04

LX04

LX04

LX11

LX11

LX04 LX04

LX05

LX15A

LX15

LX15

LX17

LX18

LX04

LX17

LX04

LX04

LX04

LX04

LX04

LX04LX04

LX05

LX05

LX05

LX05

LX04

LX04

LX04

LX04

LX15

LX15

LX15

LX15

LX15

LX15

LX15

LX15

LX15

LX15

LX15

LX15LX05

LX05

LX05

HOOVER DAM VISITOR CENTER - EXHIBIT LIGHTING LAYOUT - SOUTH

Scale: 1:502

TRACKS FOR TYPE LX04

VERTICALLY MOUNTED. EACH

TRACK TO HAVE 6 X LX04

MOUNTED ON IT

SEE #1 ON LX 201 FOR LX05

SIZE AND LOCATION

TRACKS FOR TYPE LX04

VERTICALLY MOUNTED. EACH

TRACK TO HAVE 6 X LX04

MOUNTED ON IT

TRACKS FOR TYPE LX04

VERTICALLY MOUNTED. EACH

TRACK TO HAVE 4 X LX04

MOUNTED ON IT

TYPE LX17 PAN LIGHTS

MOUNTED IN PAN (TYPICAL)

PLEASE REFER TO AV SET FOR

LX12 IN MODEL AREA. FINAL

SPECS AND PLACEMENT TO

BE CONFIRMED WITH MODEL

FABRICATOR.

TRACKS FOR TYPE LX04

VERTICALLY MOUNTED. EACH

TRACK TO HAVE 5 X LX04

MOUNTED ON IT

TRACKS FOR TYPE LX04

VERTICALLY MOUNTED. EACH

TRACK TO HAVE 6 X LX04

MOUNTED ON IT

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

H

IB

IT

L

E V

E L

P R

O

JE

C T

EXHIBIT LIGHTING

DESIGN - SOUTH

OFFICE

LX 101

DESIGNED

DRAWN

CHECKED

TECH. APPR.

Report any discrepancies to the General Contractor.

Date of Issue: 04/12/22

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

BID

SET

RECLAMATION

Designed

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

TYPE LX04 MICRO TRACK HEADS MOUNTED TO TR01 MICRO TRACKS

MICRO TRACKS MOUNTED OUT OF SIGHT IN CASE

TRACKHEADS TO BE ACCESSIBLE FOR AIMING AND DIMMING (ON BOARD)

DRIVER EC04 TO BE ACCESSIBLE IN BASE OF CASE

TRACKS MOUNTED BEHIND COLUMNS

3.1.1 PASSAGEWAY EXPERIENCE CASE

Scale: 1:251

3.1.1 PASSAGEAY EXPERIENCE - TYPE LX03 AND LX10

Scale: 1:252

SCAFFOLDING PLANKS TO BE SPACED

OUT TO ALLOW LIGHT THROUGH

TYPE LX10 TO REPLACE BASE

BUILDING LIGHTING IN AREA

AFTER EXHIBIT INSTALL.

BASE BUILDING BACKBOXES TO

BE USED FOR L08s IN TUNNEL.

TYPE LX03 TAPE LIGHT MOUNTED IN 45º

CHANNEL

THIS WALL PAINTED SKY BLUE

TYPE LX03 TAPE LIGHT MOUNTED IN 45º

CHANNEL

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

H

IB

IT

L

E V

E L

P R

O

JE

C T

EXHIBIT LIGHTING

DESIGN DETAILS

OFFICE

LX 200

DESIGNED

DRAWN

CHECKED

TECH. APPR.

Report any discrepancies to the General Contractor.

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

Designed

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

Date of Issue: 04/12/22

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

H

IB

IT

L

E V

E L

P R

O

JE

C T

EXHIBIT LIGHTING

DESIGN DETAILS

OFFICE

LX 201

DESIGNED

DRAWN

CHECKED

TECH. APPR.

Report any discrepancies to the General Contractor.

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

Designed

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

Date of Issue: 04/12/22

BID

SET

RIGHT

4.2.6 A DAY IN THE JOB

Scale: 1:251

POWER SUPPLIES AND LOCAL DIMMER TO BE

MOUNTED AND ACCESSIBLE IN THE EXHIBIT (TYPICAL)

TYPE LX04 ON TRACK MOUNTED VERTICALLY IN CASE.

TYPE LX05 - EDGE LIGHTING - INTERACTIVE WITH

AUDIO CUPS

TRACK MOUTNED IN EXHIBIT

TRACK MOUNTED IN EXHIBIT FOR LIGHTING CASES

BELOW

TYPE LX15 MURAL GRAZER

LEFT POWER SUPPLIES AND LOCAL DIMMER TO BE

MOUNTED AND ACCESSIBLE IN THE EXHIBIT

4.1.5 CONCRETE SAMPLES IN CASES 1 + 2

Scale: 1:252

TYPE LX04 TRACKHEADS TO LIGHT CASES BELOW

TYPE LX04 MOUNTED TO TRACK VERTICALLY.

MILLWORK TO HIDE TRACK AND FIXTURES (TYPICAL)

TYPE LX05 EDGE LIGHTING AROUND WINDOW

FRONT

4.1.1 SIX COMPANIES

Scale: 1:253

TYPE LX04 MOUTNED ON TRACK

2 X TYPE L17 PAN LIGHTS MOUNTED IN EXHIBIT.

EXACT LOCATION TO BE COORDINATED

TYPE LX05 EDGE LIGHTING MOUNTED AROUND

PHOTOGRAPHS. INTERACTIVE EXHIBIT.

POWER SUPPLIES AND LOCAL DIMMER TO BE

MOUNTED AND ACCESSIBLE IN THE EXHIBIT (TYPICAL)

TYPE LX06 ASSYMETRIC LINEAR MOUNTED AT TOP OF

CASE WITH FORWARD THROW

POWER SUPPLIES AND LOCAL DIMMER TO BE

MOUNTED AND ACCESSIBLE IN THE EXHIBIT (TYPICAL)

LX18

4.3.1 RAGTOWN

Scale: 1:254

POWER SUPPLIES AND LOCAL DIMMER TO BE

MOUNTED AND ACCESSIBLE IN THE EXHIBIT (TYPICAL)

TYPE LX04 TRACKHEADS

TYPE LX18 VINTAGE "OIL" LAMP

TYPE LX05 EDGE LIT PHOTOGRAPH

4.2.1 ARTIFACT CASE LIGHTING

Scale: 1:251

POWER SUPPLIES AND LOCAL DIMMER TO BE

MOUNTED AND ACCESSIBLE IN THE EXHIBIT

TYPE LX07B LINEAR MOUNTED VERTICALLY IN CASE

4.1.5 DESIGN MATERIALS AND FINISHES OVERHANG LIGHTING

Scale: 1:252

POWER SUPPLIES AND LOCAL DIMMER TO BE

MOUNTED AND ACCESSIBLE IN THE EXHIBIT

TYPE LX15 ADJUSTABLE LINEAR MOUNTED IN CASE

5.2.1 TURBINE CASE

Scale: 1:253

TYPE LX04 MOUNTED TO

VERTICALLY MOUNTED TRACK IN

CASE. ON BOARD DIMMING .

DRIVERS TO BE ACCESSIBLE AND

OUT OF SIGHT

LX09

5.2.3 TURBINE MODEL LIGHTING

Scale: 1:254

DMX CONTROLLED CBOX TO BE ACCESSIBLE IN

EXHIBIT HATCH

TYPE LX09 DMX CONTROLLED FLASHING LIGHT

MOUNTED IN EXHIBIT

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

H

IB

IT

L

E V

E L

P R

O

JE

C T

EXHIBIT LIGHTING

DESIGN DETAILS

OFFICE

LX 202

DESIGNED

DRAWN

CHECKED

TECH. APPR.

Report any discrepancies to the General Contractor.

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

Designed

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

Date of Issue: 04/12/22

CIRCUIT #1

CIRCUIT #2

CIRCUIT #3

CIRCUIT #4

CIRCUIT #5

CIRCUIT #6

CIRCUIT #7

CIRCUIT #8

CIRCUIT #9

CIRCUIT #10

CIRCUIT #11

CIRCUIT #12

CIRCUIT #13

CIRCUIT #14

CIRCUIT #15

CIRCUIT #16

CIRCUIT #17

CIRCUIT #18

TRACKS #1, 2

TRACKS #4,5

TRACKS #6, 7, 8

TRACK #11

TRACK #3

TRACKS #9, 10

TRACKS #12, 13,14, 15, 16

TRACKS #17, 18, 19

TRACK #20

IN AV PACKAGE

L03

L03

L04

L04

5.2.1 TURBINE LIGHT

IN AV PACKAGE

IN AV PACKAGE

LX13

120VAC

120VAC

LX13

LX04LX04LX04LX04EC01

POWER

SUPPLY

3.1.1 PASSAGEWAY MURAL BACKDROP

LX04LX04LX04LX04 LX04LX04

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

4.2.2 CONCRETE POUR CASE

120VAC

120VAC

EC09

DRIVER

POWER

SUPPLY

LD07

DMX

DECODER

CP01

MAC

MINI

LD03

CUE

SERVER

LD02

DMX

SPLITTER

LD13

RELAY

PANEL

LD02

DMX

SPLITTER

IN AV RACK

PATCH

BAY

TO AV NETWORK

SWITCH

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD02

DMX

SPLITTER

EC03

CBOX

LX09

IN ELECTRICAL ROOM

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

EC08

POWER

SUPPLY

LX12 LX12 LX12 LX12 LX12 LX12 LX12 LX12 LX12

LX04LX04LX04LX04

LX04LX04LX04LX04

EC01

POWER

SUPPLY

EC01

POWER

SUPPLY

3.1.1 PASSAGEWAY CASE

EC07

DIMMING

POWER

SUPPLY

LX06

LD01

SLIDE

DIMMER

0-10V

4.1.1 SIX COMPANIES CASE

4.1.5 CONCRETE SAMPLES IN CASES 1&2

LX04LX04LX04LX04

LX04LX04LX04LX04

EC01

POWER

SUPPLY

EC01

POWER

SUPPLY

4.1.4 DESIGN AND ENGINEERING CASE

EC08

DRIVER

POWER

SUPPLY

4.2.4 PAN LIGHTS

LX04LX04LX04LX04

EC01

POWER

SUPPLY

4.2.6 UNDER PLATFORM LIGHTING

EC07

DRIVER

POWER

SUPPLY

EC07

DRIVER

POWER

SUPPLY

4.1.5 DESIGN MATERALS AND FINISHES OVERHANG LIGHTING

LX04LX04LX04LX04LX04LX04LX04LX04

EC01

POWER

SUPPLY 4.3.1 RAGTOWN MURAL BACKDROP

EC07

DIMMING

POWER

SUPPLY

LX11

5.1.1 MURAL GRAZING INSIDE THE DAM MODEL

EC07

DIMMING

POWER

SUPPLY

LX11

LD01

SLIDE

DIMMER

0-10V

5.1.1 MURAL GRAZING INSIDE THE DAM MODEL

LD07

DMX

DECODER

EC09

X 4

POWER

SUPPLY

LX05

4.2.5 EDGE LIT PHOTOS

LX17

LX15 LX15

LX15 LX15

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

LD06

LIGHT

PACK

DIMMER

L01 L01 L01 L01120VAC

120VAC

120VAC

120VAC

120VAC

120VAC

LD02

DMX

SPLITTER

L02 L02 L02 L02

L02 L02 L02 L02

L02 L02 L02 L02

L02 L02 L02 L02

L02 L02 L02 L02

L02 L02 L02 L02

L02 L02 L02 L02

L02 L02 L02 L02

EC05

DIMMING

POWER

SUPPLY

LX03

3.1 PASSAGEWAY ABOVE PLANKS

EC05

DIMMING

POWER

SUPPLY

LX03

3.1 PASSAGEWAY ABOVE PLANKS

EC05

DIMMING

POWER

SUPPLY

LX03

3.1 PASSAGEWAY BELOW PLANKS

EC05

DIMMING

POWER

SUPPLY

LX03

3.1 PASSAGEWAY BELOW PLANKS

120VAC

LX04

LX04

120VAC

120VAC

120VAC

120VAC

TO EXISTING ELECTRICAL ( 5 X LX10 TO BE

CONNECTED TO EXISTING BACKBOXES IN TUNNEL)

LX10 LX10 LX10 LX10 LX10

EC05

DIMMING

POWER

SUPPLY

LX03

3.1 PASSAGEWAY ABOVE PLANKS

EC05

DIMMING

POWER

SUPPLY

LX03 3.1 PASSAGEWAY BELOW PLANKS

LD07

DMX

DECODER

EC09

X 4

POWER

SUPPLY120VAC

120VAC

120VAC

EC09

DIMMING

POWER

SUPPLY

LX05

LD01

SLIDE

DIMMER

0-10V

4.1.1 SIX COMPANIES WINDOW

LX17

EC07

DIMMING

POWER

SUPPLY

LX15A

LD01

SLIDE

DIMMER

0-10V

4.1.3 MURAL INSIDE A DAY ON THE JOB

EC07

DIMMING

POWER

SUPPLY

LX07B

4.2.1 PREPPING THE SITE ARTEFACT CASE

EC07

DIMMING

POWER

SUPPLY

LX07B

LD01

SLIDE

DIMMER

0-10V

4.2.1 PREPPING THE SITE ARTEFACT CASE

EC07

DIMMING

POWER

SUPPLY

LX07B

4.2.2 CONCRETE POUR CASE

EC07

DIMMING

POWER

SUPPLY

LX07B

LD01

SLIDE

DIMMER

0-10V

4.3.1 RAGTOWN

4.3.1 RAGTOWN EDGELIT PHOTOS (NON INTERACTIVE)

4.3.1 RAGTOWN EDGELIT PHOTOS (NON INTERACTIVE)

LX15 LX15 LX15 LX15 LX15 LX15 LX15

LX15 LX15 LX15

LX04LX04LX04LX04

LX04LX04LX04LX04

EC01

POWER

SUPPLY

EC01

POWER

SUPPLY

5.2.1 DISPLAY CASE

LX04LX04

LX04LX04

EC07

DIMMING

POWER

SUPPLY

LX08B

5.2.3 TURBINE MODEL CASES

EC07

DIMMING

POWER

SUPPLY

LX08B

LD01

SLIDE

DIMMER

0-10V

EC07

DIMMING

POWER

SUPPLY

LX08C

5.2.3 TURBINE MODEL CASES

5.2.3 TURBINE MODEL CASES

EC07

DIMMING

POWER

SUPPLY

LX08C

5.2.3 TURBINE MODEL CASES

LD01

SLIDE

DIMMER

0-10V

EACH LD06 - LIGHTPACK DMMER TO

BE ON ITS OWN DEDICATED 20AMP

CIRCUIT (TYPICAL)

LX04LX04LX04LX04EC01

POWER

SUPPLY

LX04LX04LX04LX04LX04

LX04LX04LX04LX04

LX04LX04LX04LX04

EC01

POWER

SUPPLY

EC01

POWER

SUPPLY

4.2.6 DISPLAY CASE #2

LX04LX04

LX04LX04

LX04

EC09

DIMMING

POWER

SUPPLY

LX05

LD01

SLIDE

DIMMER

0-10V

4.3.1 RAGTOWN WINDOW

EC09

DIMMING

POWER

SUPPLY

LX05

LD01

SLIDE

DIMMER

0-10V

EC09

DIMMING

POWER

SUPPLY

LX05

LD01

SLIDE

DIMMER

0-10V

LX04LX04LX04LX04

LX04LX04LX04LX04

EC01

POWER

SUPPLY

EC01

POWER

SUPPLY

4.2.3 CONSTRUCTION MODEL CASE

120VAC

LX04

LX04

X

4.1.5 DESIGN MATERALS AND FINISHES OVERHANG LIGHTING

LX04LX04LX04LX04

LX04LX04LX04LX04

EC01

POWER

SUPPLY

EC01

POWER

SUPPLY

5.3.1 EXIT DISPLAY CASE

LX04LX04

LX04LX04

HOOVER DAM VISITOR CENTER - EXHIBIT LIGHTING SYSTEM RISER

Scale: NTS1

RISER DIAGRAM LINE LEGEND

DMX

ETHERNET

POWER NON-DIM

POWER DIM

(BLUE)

(GREEN)

(RED)

(BLACK)

48 VDC (BLACK)

0-10V(BLACK)

SEE OVERHEAD LIGHTING SYSTEM

RISER (L 700) IN OVERHEAD

LIGHTING PACKAGE

241 W. Charleston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitecture.com

A

LW

AY

S

T H

IN

K

S A

FE

TY

D

C

B

A

D

C

B

A

U .S

. D E

PA

R

TM

E

N T

O F

TH

E

IN

TE

R

IO

R B

U R

E A

U O

F R

E C

LA

M

AT

IO

N

Managing Water in the West

H O

O V

E R

D A

M V

IS

IT

O R

C E

N

H

IB

IT

L

E V

E L

P R

O

JE

C T

EXHIBIT LIGHTING

DESIGN SYSTEM

RISER

OFFICE

LX 700

DESIGNED

DRAWN

CHECKED

TECH. APPR.

Report any discrepancies to the General Contractor.

Checked

Drawn

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

Designed

Eos Lightmedia Corporation www.eoslightmedia.com 825 Powell St. p: 604.639.5488 Vancouver, BC, Canada V6A 1H7

Date of Issue: 04/12/22

LX 002-NOTES
LX 003-LEGENDS AND
Viewport-3
LX 100-EXHIBIT LIGHTING DESIGN - NORTH
Viewport-15
LX 101-EXHIBIT LIGHTING DESIGN - SOUTH
Viewport-27
LX 200-EXHIBIT LIGHTING DETAILS
1/LX 102
Viewport-19
LX 201-EXHIBIT LIGHTING DETAILS
5/LX 201
5/LX 202
5/LX 203
5/LX 201AAA
LX 202-EXHIBIT LIGHTING DETAILS
Viewport-22
Viewport-23
Viewport-24
Viewport-25
LX 700-EXHIBIT LIGHTING SYSTEM RISER
1/LX 200
2/LX 202

File details come from the government source that posted it. Updated .