1011 SW Klickitat Way, Suite 104, Seattle, Washington 98134
Phone 206-381-1128
Toll Free 800-666-2959
Fax 206-254-4279
Environmental Consulting
Hazardous Materials Management
Industrial Hygiene Services
Construction Management
Indoor Air Quality
LIMITED LEAD AND ASBESTOS SURVEY REPORT
NATIONAL PARK SERVICE - OLYMPIC NATIONAL PARK
LEAD AND ASBESTOS SURVEYS
DINKLEMINN PROPERTY
875 East Beach Road
Port Angeles, Washington 98363
October 31st, 2017
Prepared For:
Jeff Doryland
Deputy Chief of Facility Management
Olympic National Park 600 E. Park Avenue, Port Angeles, WA 98273 ii
Limited Lead and Asbestos Survey Report
National Park Service – Olympic National Park
Lead and Asbestos Surveys
Dinkleminn Property
875 East Beach Road
Lake Crescent, Washington
EHSI Project No.: # 11035
The material and data in this report were prepared under the supervision and direction of the undersigned.
Rory Peterson Lead AHERA Building Inspector
Derica Escamilla Principal of Hazardous Materials
Services iii
TABLE OF CONTENTS
Acronym List .............................................................................................. iv
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
1.2 EXTENT OF CURRENT SURVEY
1.3 ACM MATERIALS FOUND
1.4 OPINIONS AND RECOMMENDATIONS
1.5 LIMITATIONS/DISCLAIMER
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
2.2 BUILDING DESCRIPTION
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
2.3.2 Lead-Containing Paint/Lead-Containing Materials
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
2.4.2 Lead-Containing Paint and Building Materials
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
2.4.4 Polychlorinated Biphenyls
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
3.0 LIMITATIONS
4.0 STANDARD OF CARE
5.0 CERTIFIED AHERA BUILDING INSPECTORS
APPENDICES
A ........................ Asbestos Laboratory Reports and Field Data Forms B ........................ Lead Laboratory Reports and Field Data Forms
C ........................Certified AHERA Building Inspector Certificates D ........................ Laboratory Certifications for Asbestos and Lead Analysis
E......................... Sample Location Drawings for Asbestos, Lead, and TCLP F......................... Lead TCLP Laboratory Reports and Field Data Forms G ........................ Abatement Cost Estimate iv
ACRONYM LIST
ACM .......................Asbestos-Containing Material
ACT ........................Acoustic Ceiling Tile
AHERA ....................Asbestos Hazard Emergency Response Act
AIHA ......................American Industrial Hygiene Association
CFL ........................Compact Fluorescent Light
CFR ........................Code of Federal Regulations
DOSH .....................Washington State Department of Labor and Industries, Division of
Occupational Safety and Health
EA..........................Each
Ecology...................Washington State Department of Ecology
EHSI.......................EHS-International, Inc.
ELLAP .....................Environmental Lead Laboratory Accreditation Program
Hg..........................Mercury
LCM........................Lead-Containing Material
LCP ........................Lead-Containing Paint
LF ..........................Linear Feet
L&I.........................Washington State Department of Labor and Industries mg/L ......................Milligrams Per Liter
N/A ........................Not Applicable
ND .........................None Detected
NVL ........................NVL Laboratories, Inc.
NVLAP ....................National Voluntary Laboratory Accreditation Program
OSHA .....................US Occupational Safety and Health Administration
ORCAA....................Olympic Clean Air Agency
Pb ..........................Lead
PCBs.......................Polychlorinated Biphenyls
PLM ........................Polarized Light Microscopy ppm .......................Parts per Million
QA .........................Quality Assurance
RCW.......................Revised Code of Washington
SAT ........................Seattle Asbestos Test, LLC
SF ..........................Square Feet
SVF ........................Sheet Vinyl Flooring
TCLP.......................Toxicity Characteristic Leaching Procedure
VAT ........................Vinyl Asbestos Tile
VCT ........................Vinyl Composite Tile
WAC.......................Washington Administrative Code
wt. .........................Weight w/ ..........................With
XRF ........................x-ray fluorescence
NPS – Lake Crescent - Dinkleminn Property
EHSI Project 11035
October 31st, 2017
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
The National Park Service (NPS) plans to demolish the existing structures on the Dinkleminn
Property located at 875 East Beach Road at Lake Crescent, Washington. The NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Dinkleminn Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure
(TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl
(PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:
interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.
1.3 ACM MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION
¼” Plywood on 9"x9" red VAT w/ non-ACM black mastic on non-ACM multi-colored SVF (w/ 3” colored square pattern) w/ non-ACM brown mesh backing w/ non-ACM gray mastic w/ non-
ACM dark gray paper backing w/ non-ACM dark brown mastic on wood subfloor [Sample # 07]
1st Floor, Bathroom
Interior ACM gray window trim putty (only on windows on west wall) [Sample #24]
1st Floor, Livingroom and 2nd Floor, Bedroom 2
Interior ACM gray window glazing putty and exterior ACM off-white window glazing putty on 2’6”x3’6” wood-framed windows
[Sample #31 and 57]
1st Floor, Kitchen, 2nd Floor, Throughout
Interior ACM gray window glazing putty and/or exterior ACM off-white window glazing putty on 1’6”x3’ wood-framed windows
[Sample #31 and 57]
Exterior, Loose on
Deck &
Exterior, Crawlspace
Below Deck
ACM brown window glazing putty in 3' wide wood door [Sample
#38] 1st Floor, Living Room
EHSI Project 11035
October 31st, 2017
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION
ACM white fibrous boards (6”x2’ to 2'x3') [Sample #40]
1st Floor, Living Room
Closet under Stairs
(loose in closet)
ACM light gray window glazing putty on 5'6”x3' wood-framed window. [Sample # 58] 1st Floor, Bathroom
KEY: ACM = asbestos containing material, SVF = sheet vinyl flooring, w/ = with, VAT = vinyl asbestos tile
1.4 OPINIONS AND RECOMMENDATIONS
The project includes demolition of the existing structures at the Dinkleminn Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.
Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).
A select number of fluorescent light fixtures inspected have magnetic ballasts which are assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. Magnetic ballasts must be removed from fixtures and disposed of as Washington Department of Ecology
(Ecology) Dangerous Waste. All fluorescent tubes and lamps contain mercury; any fluorescent lamps/tubes to be disturbed during the project must be recycled as (Ecology) Universal Waste.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. This report and accompanying appendices include the supporting information for this executive summary.
EHSI Project 11035
October 31st, 2017
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
The NPS plans to demolish the existing structures at the Dinkleminn Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:
identification of all suspect materials; a determination of whether suspect materials were:
ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.
From September 28th and 29th, 2017, EHSI conducted a Limited Lead and Asbestos Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington
Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region
Clean Air Agency (ORCAA).
2.2 BUILDING DESCRIPTION
The Dinkleminn Property is located at 875 East Beach Road, Port Angeles, Washington.
Structures on the property include a two-story single occupancy residential house, a detached two car garage with covered carport and a small painted metal storage shed located on Lake
Crescent.
The building is a wood-framed structure with post and pier foundation. The building’s roof has layering of 3-tab and wood shingles. Interior floor finishes include: hardwood, vinyl asbestos tile (VAT), linoleum, and carpet. Interior wall finishes include: wood veneer panels, tongue & groove wood planks, and painted plywood. Interior ceiling finishes include: 1’x1’ acoustical ceiling tiles (ACT), plywood, and tongue & groove wood planks. Windows are primarily wood framed however some have since been replaced with metal-framed and vinyl framed varieties; some but not all windows were operable. Hot water is provided by an electric domestic hot water tank. Heating is provided by electric baseboard units and the living room fireplace. Interior lighting consists of incandescent and fluorescent ceiling fixtures and natural light from the windows.
The detached garage is a single-story structure with poured concrete slab foundation and 3-tab roofing over the garage and corrugated sheet metal roofing over the carport. The garage has wood exterior siding and particle board interior walls with an unfinished ceiling interior.
The interior once had electrical wiring for lighting, but none was present at the time of inspection. There was no heating or plumbing for this structure.
The metal shed has metal framing with corrugated metal roof and siding. There was no electrical, heating, or plumbing for this structure.
EHSI Project 11035
October 31st, 2017
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of
Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix
C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October
1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and
Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary
Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.
Copies of both laboratories’ NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used an Olympus Delta-Pro x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial
Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program
(ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Sixty-seven (67) bulk samples of suspect ACM were collected as part of the survey. Four (4) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, EHSI Project 11035
October 31st, 2017 material description, sample location, and analytical results are summarized in Table 1. The
ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. All suspect materials were accessible for sampling.
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
Dinkleminn House
11035-DIN-
1st Floor, Living Room
Layer 1: Red brick fireplace
Layer 2: Gray mortar
L1: ND
L2: ND
N/A
N/A
11035-DIN-
02QA
1st Floor, Mud Room
Layer 1: White SVF
Layer 2: Blue/green paper backing
L1: ND
L2: ND
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Layer 1: Multi-colored SVF
(blue, gray, orange, & red sections in 3” square pattern)
Layer 2: Brown mesh backing
Layer 3: Gray mastic
Layer 4: Dark gray paper backing w/mastic
Layer 5: Wood
Layer 6: Dark brown mastic
(on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
N/A
N/A
N/A
N/A
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Layer 1: 9”x9” Multi-colored
VCT
Layer 2: Black asphaltic paper backing
Layer 3: Beige paper vapor barrier
Layer 4: Brown mastic
Layer 5: Multi-colored SVF
(green section in 3” square pattern)
Layer 6: Brown mesh
Layer 7: Dark gray paper backing w/mastic
Layer 8: Dark brown mastic
Layer 9: Wood
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
L8: ND
L9: ND
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
EHSI Project 11035
October 31st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-DIN-
1st Floor, Kitchen
Layer 1: 9”x9” Multi-colored
VCT
Layer 2: Black asphaltic paper backing
Layer 3: Beige paper vapor barrier
Layer 4: Brown mastic
Layer 5: Multi-colored SVF
(orange section in 3” square pattern)
Layer 6: Brown mesh
Layer 7: Dark gray paper backing w/mastic
Layer 8: Dark brown mastic
Layer 9: Wood
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
L8: ND
L9: ND
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11035-DIN-
1st Floor, Bathroom
Layer 1: Orange carpet
Layer 2: Brown mesh backing
Layer 3: Off-white mastic
Layer 4: Off-white/brown paper
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-
DIN-07
1st Floor, Bathroom
Layer 1: 9”x9” Red VAT
Layer 2: Black mastic
Layer 3: Wood (On Sample
11035-DIN-03)
L1: 2%
L2: ND
L3: ND
Chrysotile
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Brown paper vapor barrier
(under hardwood floor, on wood subfloor)
ND N/A
11035-DIN-
1st Floor, Living Room
Brown paper vapor barrier
(under hardwood floor, on wood subfloor)
ND N/A
11035-DIN-
1st Floor, Sun Room
Layer 1: Black/green plastic turf carpe
Layer 2: Green mesh w/ blue mastic (on hardwood)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
2nd Floor, Room 2
Layer 1: Orange/yellow carpet
Layer 2: Clear plastic
Layer 3: Off-white mastic
Layer 4: Brown mesh backing
Layer 5: Yellow/blue foam carpet pad (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A
N/A
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Orange/brown insulation (in old
2'x2'x3' electric water heater)
ND N/A
11035-DIN-
1st Floor, Mud Room
Black plastic electric panel component (in 1'x2' electrical panel)
ND N/A
EHSI Project 11035
October 31st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-DIN-
1st Floor, Mud Room
Layer 1: Red coating
Layer 2: Black asphaltic woven wrap
Layer 3: Black rubber wire insulation
Layer 4: Copper wire
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-DIN-
1st Floor, Mud Room
Layer 1: Tan coating
Layer 2: Black asphaltic woven wrap
Layer 3: Black rubber wire insulation
Layer 4: Copper wire
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Black plastic electrical component (in 2'x2'x3' electric water heater)
ND N/A
11035-DIN-
1st Floor, Kitchen
Layer 1: Black rubber wire insulation
Layer 2: Copper wire
Layer 3: Red rubber wire insulation
Layer 4: Copper wire (in
2'x2'x3' electric water heater)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Layer 1: Orange mastic
Layer 2: Brown wall paper w/ paint
Layer 3: Off-white cloth backing (on wood)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-DIN-
1st Floor, Living Room
Layer 1: Paper strips w/ brown wall paper w/ paint
Layer 2: Off-white/yellow mastic (behind wood wall panels)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
Crawlspace
Layer 1: Silver foil
Layer 2: Brown/tan paper vapor barrier w/ black mastic
Layer 3: Pink fiberglass batt insulation
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-DIN-
Crawlspace
Beige/off-white rubber roller material
ND N/A
11035-DIN-
Crawlspace
Black asphaltic vapor barrier
(wrapped around wood support column)
EHSI Project 11035
October 31st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-DIN-
1st Floor, Living Room
White window frame caulking
(on 2'x3' vinyl-framed windows)
ND N/A
11035-
DIN-24
1st Floor, Living
Room
Gray window trim putty (on windows on west wall) 15% Chrysotile
11035-DIN-
1st Floor, Living Room
Layer 1: Gray window glazing putty w/ paint
Layer 2: Wood window frame
(on 2'x3' and 5'x6' wood windows)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Brown sink drain gasket w/ paint (on large porcelain over metal sink)
ND N/A
11035-DIN-
27QA
1st Floor, Kitchen
Yellow sink edge caulking w/ paint (on large porcelain over metal sink)
ND N/A
11035-DIN-
1st Floor, Kitchen
Layer 1: Green contact paper w/ paint
Layer 2: Clear mastic (in kitchen cabinets)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
2nd Floor, Bathroom
Layer 1: Black rubber sink drain gasket
Layer 2: White putty (on porcelain sink)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
2nd Floor, Bathroom
Layer 1: White brittle sink edge putty/caulking w/ paint
(between countertop and wood cabinets)
Layer 2: Wood cabinet
L1: ND
L2: ND
N/A
N/A
11035-
DIN-31
2nd Floor, Bedroom 2
Gray window glazing putty
(on 2.5'x3.5' wood-framed windows)
15% Chrysotile
11035-DIN-
1st Floor, Bathroom
Layer 1: Off-white/gray window glazing putty w/ paint
Layer 2: Wood window frame
(on 10'x2.5’ windows)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
1st Floor, Kitchen
Yellow/tan window counter-weight cord w/ paint (on 2'x3' wood windows)
ND N/A
11035-DIN-
1st Floor, Sun Room
Brown/beige wood window frame w/ paint (in 2' wide wood doors)
EHSI Project 11035
October 31st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-DIN-
1st Floor, Kitchen
Layer 1: Beige window glazing putty w/ paint
Layer 2: Wood window frame
(in 3' wide wood door)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
1st Floor, Mud Room
Layer 1: Off-white window glazing putty w/ paint
Layer 2: Wood window frame
(in 3' wide wood door)
L1: ND
L2: ND
N/A
N/A
11035-DIN-
1st Floor, Mud Room
Black asphaltic weather stripping w/ paint (on wood door frame)
ND N/A
11035-
DIN-38
1st Floor, Living
Room
Layer 1: Brown window glazing putty w/ paint
Layer 2: Wood window frame
(in 3' wide wood door)
L1: 18%
L2: ND
Chrysotile
N/A
11035-DIN-
1st Floor, Living Room
Layer 1: Brown contact paper
Layer 2: Clear mastic (covering vent to 2nd floor)
L1: ND
L2: ND
N/A
N/A
11035-
DIN-40
1st Floor, Living
Room, Stairway
Closet
White fibrous boards (6"x2', 1'x2', & 2'x3', loose in closet)
70% Chrysotile
11035-DIN-
1st Floor, Mud Room
Gray glazing gasket (on 8’x2’6” metal-framed windows)
ND N/A
11035-DIN-
1st Floor, Mud Room
Beige/white window glazing putty (on 2'6”x3'6” wood-framed windows)
ND N/A
11035-DIN-
1st Floor, Mud Room
Brown wood fiber ACT w/ white textured paint (mechanically fastened to ceiling)
ND N/A
11035-DIN-
1st Floor, Mud Room
Brown wood fiber ACT w/ white textured paint (mechanically fastened to ceiling)
ND N/A
11035-DIN-
1st Floor, Mud Room
Brown wood fiber ACT w/ white textured paint (mechanically fastened to ceiling)
ND N/A
11035-DIN-
Exterior, N.
Side
Layer 1: Black asphaltic vapor barrier
Layer 2: Wood (behind wood siding behind sample # 11035-
DIN-47, behind metal siding)
L1: ND
L2: ND
EHSI Project 11035
October 31st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-DIN-
Exterior, N.
Side
Layer 1: Silver foil
Layer 2: White foam
Layer 3: Brown/white paper
(on wood siding behind metal siding)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-DIN-
Exterior, SE
Corner
Black asphaltic vapor barrier
(behind wood siding behind sample # 11035-DIN-47, behind metal siding)
ND N/A
11035-DIN-
Roof, NE
Corner
Layer 1: Black asphaltic 3-tab roofing w/ green sand
Layer 2: Black asphaltic 3-tab roofing w/ green sand
Layer 3: Black asphaltic 3-tab roofing w/ green sand
Layer 4: Black asphaltic vapor barrier
Layer 5: Wood Shingle (under wood shingles and black vapor barrier {layer 4} on layers 1-3 on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A
N/A
N/A
N/A
11035-DIN-
Roof, NW
Corner
Layer 1: Black asphaltic 3-tab roofing w/ green sand
Layer 2: Black asphaltic 3-tab roofing w/ green sand
Layer 3: Black asphaltic 3-tab roofing w/ green sand
Layer 4: Black asphaltic vapor barrier
Layer 5: Wood Shingle (under wood shingles and black vapor barrier {layer 4} on layers 1-3 on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A
N/A
N/A
N/A
11035-DIN-
Exterior, East Side
Orange pipe dope w/ paint (on
2" OD metal drain pipe)
ND N/A
11035-DIN-
Exterior
North Side
Red gasket w/ paint (on 3" metal electrical conduit elbow)
ND N/A
11035-DIN-
Exterior
West Side
Gray window glazing gasket w/ paint (on 8'x2’6” metal-framed windows)
ND N/A
11035-DIN-
Exterior, North Side
Beige wall penetration sealant w/ paint
EHSI Project 11035
October 31st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-DIN-
Roof, W.
Side, Above
Mud Room
Layer 1: Black asphaltic 3-tab roofing w/ orange sand
Layer 2: Black asphaltic tar
Layer 3: Black asphaltic 3-tab roofing w/ orange sand
Layer 4: Wood (beneath layers
5 & 6)
Layer 5: Black asphaltic vapor barrier
Layer 6: Black asphaltic vapor barrier
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
N/A
N/A
N/A
N/A
N/A
N/A
11035-DIN-
Exterior, Below Deck, West Side
Off-white window glazing putty w/ paint (on 1'6”x3' wood-framed window)
ND N/A
11035-
DIN-57QA1
2nd Floor, Bedroom 1
Off-white window glazing putty w/ paint (on 2.5'x3.5' wood-framed window)
3% Chrysotile
11035-
DIN-58
1st Floor, Bathroom
Layer 1: Light gray/off-white window glazing putty w/ paint
Layer 2: Wood window frame
(on 5'6”x3' window)
L1: 2%
L2: ND
Chrysotile
N/A
Detached Garage
11035-DIN-
Garage
Interior
Layer 1: Silver foil
Layer 2: Bluish gray/tan/green paper vapor barrier w/ black mastic
Layer 3: Yellow fiberglass insulation
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-DIN-
Garage
Interior
Black/gray rubber window glazing gasket (on 6'6”x3' metal-framed window)
ND N/A
11035-DIN-
Garage
Interior
Black circuit breaker (in 8"x14" electrical panel)
ND N/A
11035-DIN-
Garage
Interior
4" OD dark brown recessed light box insulation
ND N/A
11035-DIN-
Garage
Interior
Layer 1: Silver foil
Layer 2: Brown/tan paper vapor barrier
Layer 3: Yellow fiberglass insulation
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-DIN-
64QA
Garage
Exterior
Off-white window glazing putty w/ paint (on 8’x3’6” wood-framed window)
EHSI Project 11035
October 31st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-DIN-
Garage
Exterior
Black asphaltic electrical outlet gasket
ND N/A
11035-DIN-
Garage
Exterior
Layer 1: Black asphaltic 3-tab roofing w/ black, red, and tan sand
Layer 2: Black asphaltic tar
Layer 3: Black asphaltic 3-tab roofing w/ black, red, and tan sand
Layer 4: Black asphaltic tar
Layer 5: Black asphaltic 3-tab roofing w/ black, red, and tan sand
Layer 6: Black asphaltic tar
Layer 7: Clear plastic (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11035-DIN-
Garage
Exterior
Layer 1: Black asphaltic 3-tab roofing w/ black, red, and tan sand
Layer 2: Black asphaltic tar
Layer 3: Black asphaltic 3-tab roofing w/ black, red, and tan sand
Layer 4: Black asphaltic tar
Layer 5: Black asphaltic 3-tab roofing w/ black, red, and tan sand
Layer 6: Black asphaltic tar
Layer 7: Clear plastic (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
N/A
N/A
N/A
N/A
N/A
N/A
N/A
KEY: ACT = acoustic ceiling tile, ND = non-detect, N/A = not applicable, OD = outer diameter, VAT
= vinyl asbestos tile, VCT = vinyl composite tile, w/ = with, SVF = sheet vinyl flooring, 1 When QA lab and primary lab sample results differed, EHSI reported the most restrictive
(e.g., highest % asbestos) in Table 1. Analytical results for all analyses are provided in
Appendix A.
Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2
Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.
EHSI Project 11035
October 31st, 2017
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
¼” Plywood on 9"x9" red VAT w/ non-ACM black mastic on non-ACM multi-colored SVF (w/ 3” colored square pattern) w/ non-ACM brown mesh backing w/ non-ACM gray mastic w/ non-ACM dark gray paper backing w/ non-ACM dark brown mastic on wood subfloor [Sample # 07]
1st Floor, Bathroom
56 SF
Interior ACM gray window trim putty (only on windows on west wall) [Sample #24]
1st Floor, Livingroom and 2nd
Floor, Bedroom 2
12 LF
Interior ACM gray window glazing putty and exterior
ACM off-white window glazing putty on 2’6”x3’6” wood-framed windows [Sample #31 and 57]
1st Floor, Kitchen, 2nd Floor, Throughout
13 EA
Interior ACM gray window glazing putty and/or exterior
ACM off-white window glazing putty on 1’6”x3’ wood-framed windows [Sample #31 and 57]
Exterior, Loose on
Deck &
Exterior, Crawlspace Below
Deck
2 EA
ACM brown window glazing putty in 3' wide wood door
[Sample #38]
1st Floor, Living
Room
1 EA
ACM white fibrous boards (6”x2’ to 2'x3') [Sample #40]
1st Floor, Living
Room Closet under
Stairs
5 EA
ACM light gray window glazing putty on 5'6”x3' wood-framed window. [Sample # 58]
1st Floor, Bathroom
1 EA
KEY: ACM = asbestos containing material, EA = each, LF = linear feet, SF = square feet, VAT = vinyl asbestos tile, w/ = with
ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect
ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building
Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.
2.4.2 Lead-Containing Paint and Building Materials
Ninety-five (95) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer.
XRF paint sample results ranged from 3.77 milligrams of lead per square centimeter (mg
Pb/cm2) to 0 mg Pb/cm2. Bolded results indicate materials coated with “lead-based
EHSI Project 11035
October 31st, 2017 paint” (e.g., >1.0 mg/cm2) as defined by USEPA regulation 40CFR745 and
Washington State Commerce regulation WAC 365-230. The results are provided in Table
3 of this report.
EHSI also assumes the presence of two (2) lead counter weights inside wall, associated with windows above kitchen sink.
Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
Read
Component Substrate Color Building Room
Lead
Conc.
(mg/cm2)
1 NIST Check Wood Red Dinkleminn Property N/A 0.98
2 NIST Check Wood Red Dinkleminn Property N/A 0.97
3 NIST Check Wood Red Dinkleminn Property N/A 0.98
4 Door Wood Yellow Dinkleminn Property Mud Room 2.13
5 Door Frame Wood Yellow Dinkleminn Property Mud Room 0.66
6 Door Trim Wood Yellow Dinkleminn Property Mud Room 1.3
7 Wall Wood Yellow Dinkleminn Property Mud Room 0.16
8 Cabinet Wood Yellow Dinkleminn Property Mud Room <LOD
9 Window Frame Wood Yellow Dinkleminn Property Mud Room 0.19
10 Window Trim Wood Yellow Dinkleminn Property Mud Room 0.33
11 Baseboard Wood Yellow Dinkleminn Property Mud Room 0.11
12 Wall Wood Yellow Dinkleminn Property Mud Room 0.51
13 Window Wood White Dinkleminn Property Mud Room 1.85
14 Ceiling Wood White Dinkleminn Property Mud Room <LOD
15 Electrical Box Wood Yellow Dinkleminn Property Mud Room 0.62
16 Door Wood Light Green Dinkleminn Property Kitchen 3.77
17 Door Frame Wood White Dinkleminn Property Kitchen 2.24
18 Door Trim Wood Light Green Dinkleminn Property Kitchen 2.75
19 Cabinet Wood Light Green Dinkleminn Property Kitchen <LOD
20 Cabinet Wood Light Green Dinkleminn Property Kitchen 1.63
21 Cabinet Wood Light Green Dinkleminn Property Kitchen 0.27
22 Wall Wood Off White Dinkleminn Property Kitchen 0.77
23 Wall Wood Off White Dinkleminn Property Kitchen 0.02
24 Window Frame Wood Yellow Dinkleminn Property Kitchen 2.27
25 Window Wood Light Green Dinkleminn Property Kitchen 3.51
EHSI Project 11035
October 31st, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
Read
Component Substrate Color Building Room
Lead
Conc.
(mg/cm2)
26 Window Trim Wood Light Green Dinkleminn Property Kitchen 3
27 Ceiling Wood Off White Dinkleminn Property Kitchen 0.54
28 Counter Wood Brown Dinkleminn Property Kitchen <LOD
29 Door Wood White Dinkleminn Property Bathroom 0.28
30 Wall Wood Brown Dinkleminn Property Bathroom <LOD
31 Ceiling Wood Brown Dinkleminn Property Bathroom <LOD
32 Window Wood White Dinkleminn Property Bathroom <LOD
33 Window Trim Wood White Dinkleminn Property Bathroom 1.38
34 Floor Wood Red Dinkleminn Property Livingroom 0.61
35 Floor Wood White Dinkleminn Property Livingroom 0.41
36 Floor Wood Tan Dinkleminn Property Livingroom 0.55
37 Floor Wood Brown Dinkleminn Property Livingroom 0.15
38 Floor Wood Dark Brown Dinkleminn Property Livingroom 0.15
39 Baseboard Wood White Dinkleminn Property Livingroom 0.45
40 Closet Wood Dark Brown Dinkleminn Property Livingroom 0.26
41 Stairs Wood Dark Brown Dinkleminn Property Livingroom 0.18
42 Window Frame Wood White Dinkleminn Property Livingroom <LOD
43 Window Trim Wood Off White Dinkleminn Property Livingroom 0.36
44 Shelf Wood Dark Brown Dinkleminn Property Livingroom <LOD
45 Door Wood White Dinkleminn Property Sun Room 1.15
46 Floor Wood Dark Reddish
Brown Dinkleminn Property Sun Room 0.07
47 Ceiling Wood Light Gray Dinkleminn Property Sun Room <LOD
48 Door Wood Light Yellow Dinkleminn Property Sun Room 1.56
49 Door Trim Wood Light Yellow Dinkleminn Property Sun Room 1.03
50 Structural Beam Wood Yellow Dinkleminn Property Sun Room 0.73
51 Structural Beam Wood Dark Brown Dinkleminn Property Livingroom 0.18
52 Floor Wood Dark Brown Dinkleminn Property Bedroom 1 0.02
53 Wall Wood Light Brown Dinkleminn Property Bedroom 1 <LOD
54 Ceiling Wood Light Brown Dinkleminn Property Bedroom 1 <LOD
55 Window Wood Off White Dinkleminn Property Bedroom 2 <LOD
56 Chimney Brick Brick Red Dinkleminn Property Hall <LOD
57 Chimney Mortar Mortar Gray Dinkleminn Property Hall Closet <LOD
58 Shower Metal White Dinkleminn Property Bathroom <LOD
EHSI Project 11035
October 31st, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
Read
Component Substrate Color Building Room
Lead
Conc.
(mg/cm2)
59 Door Wood Light Yellow Dinkleminn Property Exterior 0.62
60 Door Frame Wood Light Yellow Dinkleminn Property Exterior 0.02
61 Door Wood Yellow Dinkleminn Property Exterior 2.3
62 Door Frame Wood Yellow Dinkleminn Property Exterior 0.62
63 Wall Metal Light Yellow Dinkleminn Property Exterior <LOD
64 Door Trim Metal Dark Brown Dinkleminn Property Exterior 0.46
65 Soffit Wood Dark Brown Dinkleminn Property Exterior <LOD
66 Fascia Wood Dark Brown Dinkleminn Property Exterior <LOD
67 Roof Flashing Metal Dark Brown Dinkleminn Property Exterior 0.03
68 Roof Flashing Metal Dark Brown Dinkleminn Property Exterior 0.02
69 Wall Trim Metal Dark Brown Dinkleminn Property Exterior <LOD
70 Gutter Metal Dark Brown Dinkleminn Property Exterior <LOD
71 Window Frame Wood Yellow Dinkleminn Property Exterior 1.38
72 Pipe 4" Plastic Yellow Dinkleminn Property Exterior <LOD
73 Pipe 2" Metal Yellow Dinkleminn Property Exterior 0.66
74 Wall Skirt Wood Brown Dinkleminn Property Exterior <LOD
75 Wall Skirt Wood Blue Dinkleminn Property Exterior 0.49
76 Gutter Metal Dark Brown Dinkleminn Property Exterior 0.01
77 Window Wood Light Yellow Dinkleminn Property Exterior 0.25
78 Stairs Wood Yellow Dinkleminn Property Exterior <LOD
79 Stair Rail Wood Dark Brown Dinkleminn Property Exterior <LOD
80 Deck Wood Dark Brown Dinkleminn Property Exterior <LOD
81 Wall Wood Yellow Dinkleminn Property Exterior 0.02
82 Wall Metal Tan Dinkleminn Property Shed 1.79
83 Wall Metal Tan Dinkleminn Property Shed 0.01
84 Wall Metal White Dinkleminn Property Shed 0.01
85 Floor Wood Gray Dinkleminn Property Sun Room 3.21
86 Walkway Railing Wood Dark Brown Dinkleminn Property Exterior <LOD
87 Ceiling Metal Dark Brown Dinkleminn Property Carport <LOD
88 Downspout Metal Dark Brown Dinkleminn Property Carport 0.01
89 Wall Wood Dark Brown Dinkleminn Property Garage
Exterior
<LOD
90 Wall Trim Wood Dark Brown Dinkleminn Property Garage
Exterior
<LOD
EHSI Project 11035
October 31st, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
Read
Component Substrate Color Building Room
Lead
Conc.
(mg/cm2)
91 Door Wood Dark Brown Dinkleminn Property Garage
Exterior
<LOD
92 Door Frame Wood Dark Brown Dinkleminn Property Garage
Exterior
<LOD
93 Door Trim Wood Dark Brown Dinkleminn Property Garage
Exterior
<LOD
94 Window Trim Wood Dark Brown Dinkleminn Property Garage
Exterior
<LOD
95 Door Wood Dark Brown Dinkleminn Property Garage
Exterior
<LOD
96 Door Wood Dark Brown Dinkleminn Property Garage
Interior
<LOD
97 Wall Wood Dark Brown Dinkleminn Property Exterior 0.01
98 Pipe 2" Metal Dark Brown Dinkleminn Property Exterior <LOD
99 NIST Check Wood Red Dinkleminn Property N/A 0.93
100 NIST Check Wood Red Dinkleminn Property N/A 0.93
101 NIST Check Wood Red Dinkleminn Property N/A 0.93
In addition to the XRF samples, EHSI collected two (2) bulk QA samples for laboratory analysis. The bulk sample results ranged from <0.0031 percent lead by weight to 1.6000 percent lead by weight. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations.
Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.
Copies of the analytical laboratory report and field data forms for lead paint are included in
Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
SAMPLE
NUMBER
LOCATION
COMPONENT/
SUBSTRATE
COLOR
RESULTS
% Pb by
WT
11035-DIN-
Pb01 1st Floor, Living Room
Chimney/Brick &
Mortar Red & Gray <0.0031
11035-
DIN-Pb02 1st Floor, Exterior
Drain
Pipe/Metal Yellow 1.600
Key: Pb = lead
EHSI Project 11035
October 31st, 2017
DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).
At the request of NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos
Survey. The results of that lead-TCLP analysis indicate leachable lead present in the anticipated demolition waste stream at a concentration of 1.2 mg/L. A detailed list of the materials included in the TCLP sample are provided in Appendix F.
It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.
2.4.4 Polychlorinated Biphenyls
Ballasts
EHSI inspected a representative number of each type of fluorescent fixture for PCB-containing ballasts. A select number of fixtures inspected were found to contain magnetic ballasts and must be assumed to contain PCB containing dialectic fluid; therefore, they must be disposed/recycled as Ecology Dangerous Waste. A Summary of ballasts and Hg-containing light tubes is provided in Table 5.
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
All fluorescent light tubes and CFL bulbs quantified in Table 5 contain Hg. Hg wastes are regulated as “universal wastes” under Ecology’s regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste. No Hg-containing switches or thermostats were identified in the structures.
TABLE 5
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
LIGHT TYPE FIXTURES
TUBES/
BULBS
MAGNETIC
BALLASTS
1’ Mounted light fixture w/ 1 bulb and 1 magnetic ballast 2 2 1
EHSI Project 11035
October 31st, 2017
TABLE 5
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – DINKLEMINN PROPERTY
LIGHT TYPE FIXTURES
TUBES/
BULBS
MAGNETIC
BALLASTS
4”x2’ Mounted light fixture w/ 2 bulbs and 1 magnetic ballast 1 2 1
1’ Diameter circular light fixtures w/ 1 CFL bulb 1 1 0
Total Dinkleminn Property 4 5 2 Key: CFL = compact fluorescent light
3.0 LIMITATIONS
This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished. All suspect materials present were accessible for sampling.
This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be
ACM by this survey report when encountered must be treated as ACM until sampled by a
Certified AHERA Building Inspector and analyzed by a certified laboratory.
4.0 STANDARD OF CARE
The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.
5.0 CERTIFIED AHERA BUILDING INSPECTORS
The Certified AHERA Building Inspectors listed below surveyed on September 28th and 29th, 2017, in accordance with federal, state, and local requirements.
Rory Peterson Mike Ruark
Certified AHERA Building Inspector Certified AHERA Building Inspector
Certificate Number: 1628987 Certificate Number: 163007
Expiration Date: August 23, 2018 Expiration Date: September 6, 2018
Appendix A
APPENDIX A
Asbestos Analytical Laboratory Report and Field Data Forms
Nick Ly, Technical Director
Client Project: 11035-01
Location: Dinkleminn Property
Dear Mr. Peterson, Enclosed please find test results for the 4 sample(s) submitted to our laboratory for analysis on
10/2/2017.
Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116
Method for the Determination of Asbestos in Bulk Building Materials.
For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.
For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.
The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results
October 4, 2017
Nick L T hnical D
Rory Peterson
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1717431.00
< Client:
Address:
Attention: Mr. Rory Peterson
Dinkleminn Property
Client Project #: 11035-01
Samples Received: 4
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 4
Project Location:
Batch #: 1717431.00
Date Received: 10/2/2017
17095337Lab ID: Client Sample #:
Location: Dinkleminn Property
11035-DIN-02QA
Layer 1 of 2 Description: White sheet vinyl
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Vinyl/Binder, Synthetic foam NDNone Detected None Detected ND
Layer 2 of 2 Description: Blue fibrous backing
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler 56%Cellulose None Detected ND
5%Synthetic fibers
17095338Lab ID: Client Sample #:
Location: Dinkleminn Property
11035-DIN-27QA
Layer 1 of 1 Description: Yellow caulking material with paint
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Caulking compound, Paint, Binder/Filler 2%Cellulose None Detected ND
17095339Lab ID: Client Sample #:
Location: Dinkleminn Property
11035-DIN-57QA
Layer 1 of 1 Description: Off-white putty material with paint
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Putty Compound, Paint, Binder/Filler 2%Cellulose Chrysotile 3%
17095340Lab ID: Client Sample #:
Location: Dinkleminn Property
11035-DIN-64QA
Layer 1 of 1 Description: Off-white putty material with paint
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Putty Compound, Paint, Binder/Filler 3%Cellulose None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Lori TsengAnalyzed by:
Nick LyReviewed by:
10/03/2017 Date:
10/04/2017Date:
Sampled by:
EHS International 1717431.00
Company NVL Batch Number
Total Number of Samples
Dinkleminn Property
5 DaysTAT
10/9/2017Due Date 10:40 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-01Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals
ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-DIN-02QA1 A17095337
11035-DIN-27QA2 A17095338
11035-DIN-57QA3 A17095339
11035-DIN-64QA4 A17095340
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Lori TsengAnalyzed by
Results Called by
NVL
NVL
10/2/17
10/3/17
Print Name
Entered By: Mohammed Jamal
Date: 10/2/2017
Time: 11:07 AM
Special
Instructions:
Appendix B
APPENDIX B
Lead Laboratory Reports and Field Data Forms
RE: Metals Analysis; NVL Batch # 1717434.00
Dear Mr. Peterson, October 5, 2017
EHS International
Rory Peterson
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil…