Text version
1011 SW Klickitat Way, Suite 104, Seattle, Washington 98134
Phone 206-381-1128
Toll Free 800-666-2959
Fax 206-254-4279
Environmental Consulting
Hazardous Materials Management
Industrial Hygiene Services
Construction Management
Indoor Air Quality
LIMITED LEAD AND ASBESTOS SURVEY REPORT
NATIONAL PARK SERVICE - OLYMPIC NATIONAL PARK
LAKE QUINAULT - BEMIS PROPERTY
658 North Shore Road
Amanda Park, Washington 98526
November 22nd, 2017
Prepared For:
Jeff Doryland
Deputy Chief of Facility Management
Olympic National Park
600 E. Park Avenue, Port Angeles, WA 98273 ii
Limited Lead and Asbestos Survey Report
National Park Service – Olympic National Park
Lake Quinault - Bemis Property
658 North Shore Road
Amanda Park, Washington
EHSI Project No.: # 11035
The material and data in this report were prepared under the supervision and direction of the undersigned.
Rory Peterson
Lead AHERA Building Inspector
Derica Escamilla
Principal of Hazardous Materials
Services iii
TABLE OF CONTENTS
Acronym List .................................................................................... iv
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
1.2 EXTENT OF CURRENT SURVEY
1.3 ACM MATERIALS FOUND
1.4 OPINIONS AND RECOMMENDATIONS
1.5 LIMITATIONS/DISCLAIMER
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
2.2 BUILDING DESCRIPTION
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
2.3.2 Lead-Containing Paint/Lead-Containing Materials
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
2.4.2 Lead-Containing Paint and Building Materials
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
2.4.4 Polychlorinated Biphenyls
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
3.0 LIMITATIONS
4.0 STANDARD OF CARE
5.0 CERTIFIED AHERA BUILDING INSPECTORS
APPENDICES
A........................ Asbestos Laboratory Reports and Field Data Forms
B........................ Lead Laboratory Reports and Field Data Forms
C........................ Certified AHERA Building Inspector Certificates
D ....................... Laboratory Certifications for Asbestos and Lead Analysis
E ........................ Sample Location Drawings for Asbestos, Lead, and TCLP
F ........................ Lead TCLP Laboratory Reports and Field Data Forms
G ....................... Abatement Cost Estimate iv
ACRONYM LIST
ACM.......................Asbestos-Containing Material
AHERA ................... Asbestos Hazard Emergency Response Act AIHA ...................... American Industrial Hygiene Association
CFL ........................ Compact Fluorescent Light CFR ....................... Code of Federal Regulations
DOSH.....................Washington State Department of Labor and Industries, Division of
Occupational Safety and Health EA ......................... Each
Ecology .................. Washington State Department of Ecology EHSI ...................... EHS-International, Inc.
ELLAP .....................Environmental Lead Laboratory Accreditation Program GWB ...................... Gypsum Wall Board
Hg ......................... Mercury JC..........................Joint Compound
LCM ....................... Lead-Containing Material
LCP........................Lead-Containing Paint L&I ........................ Washington State Department of Labor and Industries mg/cm2 .................. Milligrams Per Square Centimeter mg/L......................Milligrams Per Liter
N/A ........................Not Applicable ND.........................None Detected
NVL ....................... NVL Laboratories, Inc.
NVLAP .................... National Voluntary Laboratory Accreditation Program
OSHA ..................... US Occupational Safety and Health Administration
ORCAA ................... Olympic Region Clean Air Agency Pb ......................... Lead
PCBs ...................... Polychlorinated Biphenyls PLM ....................... Polarized Light Microscopy ppm.......................Parts per Million QA ......................... Quality Assurance
RCW ...................... Revised Code of Washington SAT ....................... Seattle Asbestos Test, LLC
SVF........................Sheet Vinyl Flooring
TCLP ...................... Toxicity Characteristic Leaching Procedure WAC ...................... Washington Administrative Code
WT ........................ Weight w/ ......................... With
XRF ....................... x-ray fluorescence
NPS – Lake Quinault - Bemis Property
EHSI Project 11035 November 21st, 2017
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
The National Park Service (NPS) plans to demolish the existing structure on the Bemis
Property located on Lake Quinault at 658 North Shore Road, Amanda Park, Washington. The NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Bemis Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure
(TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl
(PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:
interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.
1.3 ACM MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – BEMIS PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION
Electrical panels w/ assumed ACM internal components (16”x32”, 16”x24”, and 16”x22”)
1st Floor, Garage and
Exterior NE Side
Small electrical panel w/ assumed ACM internal components (6”x8”)
Exterior, NE Side
HVAC unit w/ assumed ACM internal components (2’x2’x4’) Basement, Mechanical
Room
Conditioning unit w/ assumed ACM internal components (2’x2’x2’)
Exterior, NE Side
KEY: ACM = asbestos containing material, w/ = with
EHSI Project 11035 November 21st, 2017
1.4 OPINIONS AND RECOMMENDATIONS
The project includes demolition of the existing structures at the Bemis Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.
Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).
One fluorescent light fixtures inspected has a magnetic ballast which is assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. Magnetic ballasts must be removed from fixtures and disposed of as Washington Department of Ecology (Ecology) Dangerous Waste. All fluorescent light tubes and CFL bulbs contain mercury; any fluorescent tubes/bulb to be disturbed during the project must be recycled as (Ecology) Universal Waste.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. Energized electrical panels, heating, ventilation, and air conditioning (HVAC) unit, and conditioning unit were not sampled but assumed to have ACM internal components based on the inspector’s experience with similar systems on other projects. This report and accompanying appendices include the supporting information for this executive summary.
EHSI Project 11035 November 21st, 2017
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
The NPS plans to demolish the existing structures at the Bemis Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:
identification of all suspect materials; a determination of whether suspect materials were:
ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.
On October 19th, 2017, EHSI conducted a Limited Lead and Asbestos Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of Washington
(RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region Clean Air Agency
(ORCAA).
2.2 BUILDING DESCRIPTION
The Bemis Property is located on Lake Quinault at 658 North Shore Road, Amanda Park, Washington. The structure on the property is a two-story single occupancy residential house, consisting of a first floor, a daylight basement, and an attached two car garage.
The building is a wood-framed structure with a concrete foundation. The building’s roof has layering of wood shingles. Interior floor finishes include: sheet vinyl flooring (SVF), ceramic floor tiles, and carpet. Interior wall finishes include: texturing on GWB, various patterns of wall paper on GWB, and unfinished GWB. Interior ceiling finishes include: texturing on GWB, finished GWB, and unfinished GWB. Windows are all wood-framed and are both operable and inoperable. Hot water is provided by an electric domestic hot water tank. Heating is provided by a HVAC unit in the mechanical room which distributes heat via ducting to floor vents.
Interior lighting consists of incandescent and fluorescent ceiling fixtures and natural light from the windows.
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of
Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October
1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
EHSI Project 11035 November 21st, 2017
EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.
Copies of both laboratories’ NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used a Niton Model XLp x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program
(ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Sixty-eight (68) bulk samples of suspect ACM were collected as part of the survey. Four (4) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. Suspect materials not sampled were assumed to be ACM.
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
BEMIS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
BEM-01
1st Floor, Bed 2
Closet
Layer 1: Thick pink carpet Layer 2: Black mesh backing
Layer 3: Off-white mastic Layer 4: White mesh backing
Layer 5: Blue carpet pad (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A N/A
N/A N/A
N/A
11035-
BEM-02
1st Floor, Hallway
Closet
Layer 1: Light blue carpet
Layer 2: Off-white mastic Layer 3: Beige mesh backing
Layer 4: Blue foam carpet pad
(on wood)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
BEM-03
1st Floor, Master
Bedroom Closet
Layer 1: Pink carpet
Layer 2: Off-white mastic
Layer 3: White mesh backing Layer 4: Blue foam carpet pad
(on wood)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A N/A
11035-
BEM-04
1st Floor, Master Bath
Layer 1: Beige SVF Layer 2: Off-white backing
Layer 3: Clear mastic (on wood)
L1: ND
L2: ND
L3: ND
N/A N/A
N/A
11035-
BEM-05
1st Floor, Bed 2
Layer 1: Thin blue carpet Layer 2: Tan mastic (on wood)
L1: ND
L2: ND
N/A N/A
11035-
BEM-06
1st Floor, Kitchen Pantry
Layer 1: Light blue/light gray ceramic floor tiles (in geometric pattern)
Layer 2: Off-white mesh Layer 3: Dark gray grout
Layer 4: Brown mortar (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
BEM-07
Basement, Bed 6
Layer 1: Brown multi-color carpet Layer 2: Beige mastic
Layer 3: White mesh backing Layer 4: Tan carpet pad
Layer 5: Brown mastic
Layer 6: Concrete
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
N/A
N/A
N/A N/A
N/A
N/A
11035-
BEM-08
Basement, Bed 4
Layer 1: Light brown carpet
Layer 2: Off-white mastic
Layer 3: White mesh backing (on concrete)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
BEM-09
Basement, Bed 5
Layer 1: Thick blue carpet
Layer 2: Clear mesh backing Layer 3: Yellow foam carpet pad
Layer 4: Tan mastic Layer 5: Concrete
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A N/A
N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
BEMIS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
BEM-10
1st Floor, Living
Room
Layer 1: Red chimney/fireplace brick
Layer 2: Gray mortar
L1: ND
L2: ND
N/A
N/A
11035-
BEM-11
Attic Above Garage
Black asphaltic vapor barrier (between wood framing and wood roof decking)
ND N/A
11035-
BEM-12QA
Attic Above Living
Room
Black asphaltic felt vapor barrier (between wood framing and wood roof decking)
ND N/A
11035-
BEM-13
Attic Above Living
Room
Layer 1: Brown paper vapor barrier w/ black mastic
Layer 2: Yellow fiberglass attic insulation
L1: ND
L2: ND
N/A
N/A
11035-
BEM-14
1st Floor, Bedroom 1
Layer 1: Brown window glazing putty Layer 2: Wood-framed window
L1: ND
L2: ND
N/A
N/A
11035-
BEM-15
1st Floor, Living Room
Layer 1: Brown window glazing putty Layer 2: Wood-framed window
L1: ND
L2: ND
N/A
N/A
11035-
BEM-16
1st Floor, Kitchen
Layer 1: Brown window glazing putty Layer 2: Wood-framed bay window
L1: ND
L2: ND
N/A
N/A
11035-
BEM-17
1st Floor, Garage
Unfinished GWB wall and ceiling panels w/ paper
ND N/A
11035-
BEM-18
1st Floor, Bedroom 2
Layer 1: JC w/ paint and paper
(w/ troweled-on textured paint in shell pattern)
Layer 2: GWB wall w/ paper (corner)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-19
1st Floor, Bedroom 2
GWB wall w/ paint and paper
(mid wall) (w/ troweled-on textured paint in shell pattern)
ND N/A
11035-
BEM-20
1st Floor, Bedroom 2
GWB wall w/ paint and paper
(mid wall) (w/ troweled-on textured paint in shell pattern)
ND N/A
11035-
BEM-21
1st Floor, Bathroom
Layer 1: Off-white wall paper
(w/ floral pattern w/ vertical stripes)
Layer 2: Trace clear mastic
Layer 3: Texturing skim coat w/ paint
Layer 4: GWB wall w/ paper (corner)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
BEMIS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
BEM-22
1st Floor, Hall
Layer 1: White/off-white wall paper (w/ floral pattern)
Layer 2: Trace clear mastic Layer 3: Trace texturing skim coat w/ paint Layer 4: GWB wall w/ paper
(mid wall)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
BEM-23
1st Floor, Master Bathroom
Layer 1: Beige wall paper (grass pattern)
Layer 2: Trace clear mastic
Layer 3: Texturing skim coat w/ paint
Layer 4: GWB wall w/ paper (corner)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-
BEM-24
1st Floor, Dining Room
Layer 1: Beige wall paper (fern pattern) Layer 2: Trace clear mastic
Layer 3: Trace texturing skim coat w/ paint
Layer 4: GWB wall w/ paper (mid wall)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-
BEM-25
1st Floor, Bedroom 1
Layer 1: Beige wall paper
(vertical stripe pattern) Layer 2: Trace clear mastic
Layer 3: Texturing skim coat w/ paint Layer 4: GWB wall w/ paper
(corner)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-
BEM-26
1st Floor, Kitchen
Layer 1: White wall paper (small diamond pattern)
Layer 2: Trace clear mastic Layer 3: Texturing skim coat w/ paint Layer 4: GWB wall w/ paper
(mid wall)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
BEM-27
1st Floor, Living Room
Layer 1: Texturing skim coat w/ paint
Layer 2: GWB wall w/ paper (mid wall)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-28
Basement Bar
Layer 1: 4” Brown cove base
Layer 2: Beige mastic Layer 3: Trace texturing w/ paint
L1: ND
L2: ND
L3: ND
N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
BEMIS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
BEM-29
Basement
Bar
Layer 1: Large splotch texturing w/ paint
Layer 2: GWB wall w/ paper (corner)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-30
Basement Bar
Layer 1: Large splotch texturing w/ paint Layer 2: GWB wall w/ paper
(mid wall)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-31
Basement, Bedroom 4
Layer 1: Large splotch texturing w/ paint and paper
Layer 2: GWB wall w/ paper (corner)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-32
Basement, Bedroom 5
Layer 1: Large splotch texturing w/ paint Layer 2: GWB wall w/ paper
(mid wall)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-33
Basement, Bathroom
Layer 1: Gray wall paper Layer 2: Trace clear mastic
Layer 3: Blue wall paper
Layer 4: Trace clear mastic Layer 5: Large splotch texturing w/ paint Layer 6: GWB wall w/ paper
(mid wall)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
N/A N/A
N/A
N/A N/A
N/A
11035-
BEM-34QA
1st Floor, Living
Room
Layer 1: Brown window glazing putty (in 5’x7’ sliding glass doors) Layer 2: Wood door
L1: ND
L2: ND
N/A
N/A
11035-
BEM-35
1st Floor, Bathroom
Layer 1: JC w/ paint and paper
Layer 2: GWB ceiling w/ paper (ceiling edge)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-36
1st Floor, Bathroom
GWB ceiling w/ paint and paper
(mid ceiling)
ND N/A
11035-
BEM-37
1st Floor, Hall
GWB ceiling w/ paint and paper (mid ceiling)
ND N/A
11035-
BEM-38
1st Floor, Bedroom 2
Layer 1: Sparse popcorn ceiling texturing w/ paint Layer 2: GWB ceiling w/ paper
(ceiling edge)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-39
1st Floor, Bedroom 2
Layer 1: Sparse popcorn ceiling texturing w/ paint
Layer 2: GWB ceiling w/ paper (mid ceiling)
L1: ND
L2: ND
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
BEMIS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
BEM-40
1st Floor, Kitchen
Layer 1: Sparse popcorn ceiling texturing w/ paint
Layer 2: GWB ceiling w/ paper (mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-41
1st Floor, Master
Bedroom
Layer 1: Texturing w/ paint and paper Layer 2: GWB ceiling w/ paper
(ceiling edge)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-42
1st Floor, Master Bedroom
Layer 1: Trace texturing w/ paint
Layer 2: GWB ceiling w/ paper (mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-43
1st Floor, Master
Bedroom
Layer 1: Trace texturing w/ paint Layer 2: GWB ceiling w/ paper
(mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-44
1st Floor, Living Room
Layer 1: Large splotch texturing w/ paint
Layer 2: GWB ceiling w/ paper
(ceiling edge)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-45
1st Floor, Living
Room
Layer 1: Large splotch texturing w/ paint
Layer 2: GWB ceiling w/ paper (mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-46
1st Floor, Dining Room
Layer 1: Large splotch texturing w/ paint Layer 2: GWB ceiling w/ paper
(mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-47
Basement
Bar
Layer 1: Large splotch texturing (w/ sporadic popcorn like texturing) w/ paint Layer 2: GWB ceiling w/ paper
(ceiling edge)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-48
Basement
Bar
Layer 1: Large splotch texturing (w/ sporadic popcorn like texturing) w/ paint Layer 2: GWB ceiling w/ paper
(mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-49
1st Floor, Bedroom 6
Layer 1: Large splotch texturing (w/ sporadic popcorn like texturing) w/ paint Layer 2: GWB ceiling w/ paper
(ceiling edge)
L1: ND
L2: ND
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
BEMIS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
BEM-50
1st Floor, Bedroom 5
Layer 1: Large splotch texturing (w/ sporadic popcorn like texturing) w/ paint Layer 2: GWB ceiling w/ paper
(mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-51
1st Floor, Mechanical Room
Layer 1: Large splotch texturing (w/ sporadic popcorn like texturing) w/ paint Layer 2: GWB ceiling w/ paper
(mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-52
1st Floor, Hall
Layer 1: Silver foil Layer 2: White insulation
Layer 3: Beige/yellow mastic
(on 10” OD light fixtures)
L1: ND
L2: ND
L3: ND
N/A N/A
N/A
11035-
BEM-53
Basement
Bar
Layer 1: Brown paper vapor barrier w/ black mastic
Layer 2: Yellow fiberglass insulation (in walls)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-54QA
1st Floor, Bathroom
Layer 1: Clear/beige bathtub caulking Layer 2: White bathtub caulking
L1: ND
L2: ND
N/A
N/A
11035-
BEM-55
1st Floor, Bathroom
Layer 1: Rose/purple Formica™ countertop Layer 2: Clear mastic
Layer 3: Fiberboard
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
BEM-56
1st Floor, Bathroom
Layer 1: Black rubber sink drain gasket
Layer 2: Light gray plastic gasket (single ceramic sink)
L1: ND
L2: ND
N/A
N/A
11035-
BEM-57
1st Floor, Garage
Remnant black cove base mastic
(along SE wall)
ND N/A
11035-
BEM-58
1st Floor, Master Bath
Layer 1: 2”x2” Brown ceramic wall tile (used as countertop and backsplash) Layer 2: Dark brown grout
Layer 3: Dark brown grout Layer 4: Tan mastic
Layer 5: Yellow mastic Layer 6: Trace GWB w/ paper
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
N/A
N/A
N/A N/A
N/A N/A
11035-
BEM-59
1st Floor, Master Bath
Layer 1: 6”x8” Light brown ceramic tile (bathtub backsplash)
Layer 2: Dark brown grout
Layer 3: Beige mastic (on GWB)
L1: ND
L2: ND
L3: ND
N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
BEMIS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
BEM-60
1st Floor, Kitchen
Layer 1: Blue/gray Formica™ countertop
Layer 2: Tan mastic Layer 3: Fiberboard
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-
BEM-61
1st Floor, Kitchen
Layer 1: 6”x8” Light brown ceramic tile (used as countertop and backsplash)
Layer 2: Dark gray grout Layer 3: Trace tan grout
Layer 4: Fiberboard
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
BEM-62
Basement
Bar
Layer 1: Wood pattern Formica™ countertop
Layer 2: Brown mastic
Layer 3: Fiberboard
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
BEM-63
1st Floor, Bathroom
Layer 1: Light blue Formica™
(countertop, backsplash, upper shower backsplash) Layer 2: Cream colored mastic
Layer 3: Trace GWB Layer 4: Yellow/cream colored countertop caulking
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A N/A
11035-
BEM-64
1st Floor, Bathroom
Layer 1: Wood wall panel Layer 2: Black mastic (mastic only at seams)
L1: ND
L2: ND
N/A N/A
11035-
BEM-65
Exterior Roof, West
Corner
Layer 1: Black asphaltic vapor barrier (under wood shingles on wood decking) Layer 2: Trace wood
L1: ND
L2: ND
N/A
N/A
11035-
BEM-66QA
Exterior
Roof, North
Corner
Layer 1: Black asphaltic felt vapor barrier (under wood shingles on wood decking)
Layer 2: Trace wood
L1: ND
L2: ND
N/A
N/A
11035-
BEM-67
Exterior Roof, NE
Side
White paper vapor barrier
(under wood siding)
ND N/A
11035-
BEM-68
Exterior South
Corner
White paper vapor barrier
(under wood siding)
ND N/A
KEY: GWB = gypsum wall board, JC = joint compound, ND = non-detect, N/A = not applicable, SVF
= sheet vinyl flooring, w/ = with
Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2
EHSI Project 11035 November 21st, 2017
Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – BEMIS PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
Electrical panels w/ assumed ACM internal components (16”x32”, 16”x24”, and 16”x22”)
1st Floor, Garage and Exterior NE Side
4 EA
Small electrical panel w/ assumed ACM internal components (6”x8”) Exterior, NE Side 1 EA
HVAC unit w/ assumed ACM internal components (2’x2’x4’)
Basement, Mechanical Room 1 EA
Conditioning unit w/ assumed ACM internal components (2’x2’x2’) Exterior, NE Side 1 EA
KEY: ACM = asbestos containing material, EA = each, w/ = with
ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.
2.4.2 Lead-Containing Paint and Building Materials
Fifty-nine (59) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer.
XRF paint sample results ranged from 1.1 milligrams of lead per square centimeter (mg
Pb/cm2) to <LOD. Bolded results indicate materials coated with “lead-based paint”
(e.g., >1.0 mg/cm2) as defined by USEPA regulation 40CFR745 and Washington State Commerce regulation WAC 365-230. The results are provided in Table 3 of this report.
Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.
EHSI Project 11035 November 21st, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – BEMIS PROPERTY
Read
Component Substrate Color Building Room
Lead Conc.
(mg/cm2)
1 SELF CALIBRATION N/A N/A BEMIS PROPERTY N/A 0
2 CALIBRATION N/A RED BEMIS PROPERTY N/A 0.5
3 CALIBRATION N/A RED BEMIS PROPERTY N/A 0.1
4 CALIBRATION N/A RED BEMIS PROPERTY N/A 0.1
5 CALIBRATION N/A RED BEMIS PROPERTY N/A 0.1
6 SIDING WOOD WHITE BEMIS PROPERTY EXTERIOR 0.03
7 TRIM WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
8 SIDING WOOD LIGHT BROWN BEMIS PROPERTY EXTERIOR 0.03
9 GARAGE DOOR TRIM WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
10 GARAGE DOOR WOOD WHITE BEMIS PROPERTY EXTERIOR 0.03
11 DOOR WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
12 DOOR TRIM WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
RELITE WINDOW
TRIM
WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
14 PORCH RAILING WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
15 SOFFIT WOOD WHITE BEMIS PROPERTY EXTERIOR 0.03
16 FASCIA WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
17 GUTTER METAL BROWN BEMIS PROPERTY EXTERIOR 0.03
18 SCREEN DOOR METAL BLACK BEMIS PROPERTY EXTERIOR 0.03
19 WINDOW TRIM WOOD BROWN BEMIS PROPERTY EXTERIOR 0.03
20 DOWN SPOUT METAL WHITE BEMIS PROPERTY EXTERIOR 0.03
21 FOUNDATION CONCRETE BROWN BEMIS PROPERTY EXTERIOR 0.03
22 COUNTERTOP CERAMIC LIGHT GRAY BEMIS PROPERTY KITCHEN 0.1
23 FLOOR CERAMIC LIGHT GRAY BEMIS PROPERTY KITCHEN 0.03
24 WALL DRYWALL WHITE BEMIS PROPERTY KITCHEN 0.03
25 DOOR WOOD BROWN BEMIS PROPERTY KITCHEN 0.03
26 WALL DRYWALL BEIGE BEMIS PROPERTY ENTRY 0.03
27 WALL DRYWALL BEIGE BEMIS PROPERTY BED 1 0.03
28 WALL DRYWALL BEIGE BEMIS PROPERTY BATHROOM 0.03
29 TOILET CERAMIC ROSE BEMIS PROPERTY BATHROOM 0.03
30 SINK CERAMIC ROSE BEMIS PROPERTY BATHROOM 1.1
31 BATHTUB CERAMIC ROSE BEMIS PROPERTY BATHROOM 0.47
32 ELECTRICAL PANEL METAL GRAY BEMIS PROPERTY GARAGE 0.03
33 WALL DRYWALL OFF WHITE BEMIS PROPERTY BED 2 0.03
EHSI Project 11035 November 21st, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – BEMIS PROPERTY
Read
Component Substrate Color Building Room
Lead Conc.
(mg/cm2)
34 CLOSET DOOR WOOD OFF WHITE BEMIS PROPERTY BED 2 0.3
35 WALL DRYWALL OFF WHITE BEMIS PROPERTY BED 2 0.03
36 WALL DRYWALL OFF WHITE BEMIS PROPERTY LIVING ROOM 0.03
DECORATIVE
COLUMN
WOOD DARK BROWN BEMIS PROPERTY LIVING ROOM 0.03
38 FIREPLACE BRICK BRICK BEMIS PROPERTY LIVING ROOM 0.03
39 WALL DRYWALL WHITE BEMIS PROPERTY
MASTER
BEDROOM
0.03
40 SINK CERAMIC LIGHT BROWN BEMIS PROPERTY MASTER BATH 1.1
41 COUNTERTOP CERAMIC LIGHT BROWN BEMIS PROPERTY MASTER BATH 0.03
42 BATHTUB CERAMIC LIGHT BROWN BEMIS PROPERTY MASTER BATH 0.53
BATHTUB
BACKSPLASH
CERAMIC LIGHT BROWN BEMIS PROPERTY MASTER BATH 0.1
44 WALL DRYWALL LIGHT BLUE BEMIS PROPERTY BAR 0.03
45 CABINET WOOD LIGHT BROWN BEMIS PROPERTY BAR 0.03
46 TANK METAL BEIGE BEMIS PROPERTY
MECHANICAL
ROOM
0.03
47 TOILET CERAMIC LIGHT BLUE BEMIS PROPERTY BATHROOM 0.03
48 SINK CERAMIC LIGHT BLUE BEMIS PROPERTY BATHROOM 1.1
49 WALL DRYWALL LIGHT GRAY BEMIS PROPERTY BATHROOM 0.03
50 WALL WOOD BROWN BEMIS PROPERTY BATHROOM 0.03
51 WALL DRYWALL FUCHSIA BEMIS PROPERTY BED 4 0.03
52 CLOSET DOOR WOOD WHITE BEMIS PROPERTY BED 4 0.3
53 WALL DRYWALL LIGHT BLUE BEMIS PROPERTY LIVING ROOM 0.03
54 CEILING DRYWALL LIGHT BLUE BEMIS PROPERTY BAR 0.03
55 CEILING DRYWALL WHITE BEMIS PROPERTY BAR 0.03
56 CEILING DRYWALL WHITE BEMIS PROPERTY BAR 0.03
57 DOOR METAL OFF WHITE BEMIS PROPERTY BED 6 0.03
58 SELF CALIBRATION N/A RED BEMIS PROPERTY N/A 0.1
59 CALIBRATION N/A RED BEMIS PROPERTY N/A 0.1
60 CALIBRATION N/A RED BEMIS PROPERTY N/A 0.1
Key: N/A = not applicable
In addition to the XRF samples, EHSI collected two (2) bulk QA samples for laboratory analysis. The bulk sample results were <0.0053 and <0.0038 percent lead by weight (below the reporting limit). Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts
EHSI Project 11035 November 21st, 2017 of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations.
Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.
Copies of the analytical laboratory report and field data forms for lead paint are included in Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE QUINAULT – BEMIS PROPERTY
SAMPLE
NUMBER
LOCATION
COMPONENT/
SUBSTRATE
COLOR
RESULTS
% Pb by
WT
11035-BEM-Pb01 House, 1st Floor, Living
Room
Chimney /
Brick and Mortar Red / Gray <0.0038
11035-BEM-Pb02 House, 1st Floor, Exterior Soffit / Wood Light Gray <0.0056 Key: Pb = lead, WT = weight
DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).
At the request of NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos
Survey. The results of that lead-TCLP analysis indicate no leachable lead was present in the anticipated demolition waste stream above the laboratories reporting limit at a concentration of <0.5 mg/L. A detailed list of the materials included in the TCLP sample are provided in Appendix F.
It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.
EHSI Project 11035 November 21st, 2017
2.4.4 Polychlorinated Biphenyls
Ballasts
EHSI inspected a representative number of each type of fluorescent fixture for PCB-containing ballasts. One fixtures inspected was found to contain a magnetic ballast and must be assumed to contain PCB containing dialectic fluid; therefore, it must be disposed/recycled as Ecology
Dangerous Waste. A Summary of ballasts and Hg-containing light tubes/bulbs is provided in Table 5.
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
All fluorescent light tubes and CFL bulbs quantified in Table 5 contain Hg. Hg wastes are regulated as “universal wastes” under Ecology’s regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste. No Hg-containing switches or thermostats were identified in the structures.
TABLE 5
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
NATIONAL PARK SERVICE
LAKE QUINAULT – BEMIS PROPERTY
LIGHT TYPE FIXTURES
TUBES/
BULBS
MAGNETIC
BALLASTS
6”x4’ Light fixture w/ 2 bulbs and 1 electronic ballast
1 2 0
6”x4’ Light fixture w/ 2 bulbs and 1 magnetic ballast 1 2 1
Light fixtures w/ CFL bulbs 43 43 0
Total Bemis Property 45 47 1 Key: CFL = compact fluorescent light, w/ = with
3.0 LIMITATIONS
This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished; energized electrical panels, heating, ventilation, and air conditioning (HVAC) unit, and conditioning unit were not sampled but assumed to have ACM internal components.
This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be
ACM by this survey report when encountered must be treated as ACM until sampled by a Certified AHERA Building Inspector and analyzed by a certified laboratory.
EHSI Project 11035 November 21st, 2017
4.0 STANDARD OF CARE
The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.
5.0 CERTIFIED AHERA BUILDING INSPECTORS
The Certified AHERA Building Inspectors listed below surveyed on October 19th, 2017, in accordance with federal, state, and local requirements.
Rory Peterson Micki Towler
Certified AHERA Building Inspector Certified AHERA Building Inspector Certificate Number: 1628987 Certificate Number: 2016-12-09-01
Expiration Date: August 23, 2018 Expiration Date: December 9, 2017
Appendix A
APPENDIX A
Asbestos Analytical Laboratory Report and Field Data Forms
Nick Ly, Technical Director
Client Project: 11035-04
Location: Bemis Property
Dear Mr. Peterson, Enclosed please find test results for the 4 sample(s) submitted to our laboratory for analysis on
10/23/2017.
Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116
Method for the Determination of Asbestos in Bulk Building Materials.
For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.
For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.
The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results
October 27, 2017
Nick L T hnical D
Rory Peterson
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1718862.00
< Client:
Address:
Attention: Mr. Rory Peterson
Bemis Property
Client Project #: 11035-04
Samples Received: 4
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 4
Project Location:
Batch #: 1718862.00
Date Received: 10/23/2017
17102744Lab ID: Client Sample #:
Location: Bemis Property
11035-BEM-12QA
Layer 1 of 1 Description: Black asphaltic fibrous felt
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Fine particles 65%Cellulose None Detected ND
17102745Lab ID: Client Sample #:
Location: Bemis Property
11035-BEM-34QA
Layer 1 of 1 Description: Brown soft material on wood
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Caulking compound, Fine grains 2%Cellulose None Detected ND
<1%Synthetic fibers
17102746Lab ID: Client Sample #:
Location: Bemis Property
11035-BEM-54QA
Layer 1 of 1 Description: Off-white soft elastic material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Caulking compound, Fine particles 2%Cellulose None Detected ND
2%Synthetic fibers
17102747Lab ID: Client Sample #:
Location: Bemis Property
11035-BEM-66QA
Layer 1 of 1 Description: Black asphaltic fibrous felt
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Fine particles 65%Cellulose None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Robert LetchworthAnalyzed by:
Nick LyReviewed by:
10/26/2017 Date:
10/27/2017Date:
Sampled by:
EHS International 1718862.00
Company NVL Batch Number
Total Number of Samples
Bemis Property
5 DaysTAT
10/30/2017Due Date 10:15 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-04Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals
ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-BEM-12QA1 A17102744
11035-BEM-34QA2 A17102745
11035-BEM-54QA3 A17102746
11035-BEM-66QA4 A17102747
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Robert LetchworthAnalyzed by
Results Called by
NVL
NVL
10/23/17
10/26/17
Print Name
Entered By: Umer Khan
Date: 10/23/2017
Time: 10:23 AM
Special
Instructions:
Appendix B
APPENDIX B
Lead Laboratory Reports and Field Data Forms
RE: Metals Analysis; NVL Batch # 1718864.00
Dear Mr. Peterson, October 27, 2017
EHS International
Rory Peterson
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.
This report is considered highly confidential and will not be released without your approval.
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.
Sincerely, Analysis Report Total Lead (Pb)
Bemis Property
EHS InternationalClient:
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Mr. Rory PetersonAttention:
Address:
Project Location: Samples Received: 2
Samples Analyzed: 2
Client Project #: 11035-04
Batch #: 1718864.00
Date Received: 10/23/2017
Lab ID Client Sample #
Sample
Weight (g)
Results in mg/Kg
Results in percent
RL in mg/Kg
Matrix: Paint
Method: EPA 3051/7000B
17102751 11035-BEM-Pb01 0.2636 38 < 38 0.0038<
17102752 11035-BEM-Pb02 0.1779 56 < 56 0.0056<
ClientSampled by:
Yasuyuki HidaAnalyzed by:
Nick LyReviewed by:
10/26/2017Date Analyzed:
10/27/2017Date Issued:
Bench Run No: 2017-1026-6 mg/ Kg =Milligrams per kilogram RL = Reporting Limit
Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit Note : Method QC results are acceptable unless stated otherwise.
Unless otherwise indicated, the condition of all samples was acceptable at time of receipt.
EHS International 1718864.00
Company NVL Batch Number
Total Number of Samples
Bemis Property
5 DaysTAT
10/30/2017Due Date 10:15 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-04Project Name/Number: Project Location:
Sample ID Description A/RLab ID
LEAD LABORATORY SERVICES
Subcategory
Item Code
Flame AA (FAA)
Metals
FAA-02 EPA 7000B Lead by FAA <paint>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-BEM-Pb011 A17102751
11035-BEM-Pb022 A17102752
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Yasuyuki HidaAnalyzed by
Results Called by
NVL
NVL
10/23/17
10/26/17
Print Name
Entered By: Mohammed Jamal
Date: 10/23/2017
Time: 10:28 AM
Special
Appendix C
APPENDIX C
Certified AHERA Building Inspector Certificates
Appendix D
APPENDIX D
Laboratory Certifications for Asbestos and
Lead Analysis
AIHA Laboratory Accreditation Programs, LLC acknowledges that
NVL Laboratories, Inc.
4708 Aurora Avenue N., Seattle, WA 98103
Laboratory ID: 101861 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation
Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: June 01, 2019
ENVIRONMENTAL LEAD Accreditation Expires: June 01, 2019
ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: June 01, 2019
FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires: June 01, 2019
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC
17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA-
LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
William Walsh, CIH
Chairperson, Analytical Accreditation Board
Cheryl O. Morton
Managing Director, AIHA Laboratory Accreditation Programs, LLC
Revision 15: 03/30/2016 Date Issued: 05/31/2017
Effective: 04/10/2015
101861_Scope_IHLAP_2017_05_31
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
Industrial Hygiene Laboratory Accreditation Program (IHLAP)
Initial Accreditation Date: 04/01/1997
IHLAP Scope
Category
Field of Testing (FoT)
(FoTs cover all relevant
IH matrices)
Technology sub-type/
Detector
Published Reference
Method/Title of In-house Method
Method Description or Analyte (for internal methods only)
Spectrometry Core
Inductively-Coupled
Plasma
ICP/AES
EPA 3051
NIOSH 7300 Modified
X-ray Diffraction (XRD) NIOSH 7500
Asbestos/Fiber
Microscopy Core
Phase Contrast
Microscopy (PCM)
NIOSH 7400
Miscellaneous Core Gravimetric NIOSH 0500 Modified
NIOSH 0600 Modified
A complete listing of currently accredited Industrial Hygiene laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org
Effective: 10/14/2016
Scope_ELLAP_R7
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017
The laboratory is approved for those specific field(s) of testing/methods listed in the table below.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.