Attchmt 17_Option 2-Hoiness Property Report.pdf
PDF 18 MB Posted
- Attached to
- Hazardous Materials Abatement, OLYM
- Solicitation number
- 140P8318Q0051
About this file
Attachment 17 - lead and asbestos survey report for optional Hoiness property site
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIMITED LEAD AND ASBESTOS SURVEY REPORT
NATIONAL PARK SERVICE - OLYMPIC NATIONAL PARK
LAKE QUINAULT - HOINESS PROPERTY
604 North Shore Road
Amanda Park, Washington 98526
November 21st, 2017
Prepared For:
Jeff Doryland
Deputy Chief of Facility Management
Olympic National Park
600 E. Park Avenue, Port Angeles, WA 98273 ii
Limited Lead and Asbestos Survey Report
National Park Service – Olympic National Park
Lake Quinault - Hoiness Property
604 North Shore Road
Amanda Park, Washington
EHSI Project No.: # 11035
The material and data in this report were prepared under the supervision and direction of the undersigned.
Rory Peterson
Lead AHERA Building Inspector
Derica Escamilla
Principal of Hazardous Materials
Services iii
TABLE OF CONTENTS
Acronym List .................................................................................... iv
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
1.2 EXTENT OF CURRENT SURVEY
1.3 ACM MATERIALS FOUND
1.4 OPINIONS AND RECOMMENDATIONS
1.5 LIMITATIONS/DISCLAIMER
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
2.2 BUILDING DESCRIPTION
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
2.3.2 Lead-Containing Paint/Lead-Containing Materials
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
2.4.2 Lead-Containing Paint and Building Materials
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
2.4.4 Polychlorinated Biphenyls
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
3.0 LIMITATIONS
4.0 STANDARD OF CARE
5.0 CERTIFIED AHERA BUILDING INSPECTORS
APPENDICES
A........................ Asbestos Laboratory Reports and Field Data Forms
B........................ Lead Laboratory Reports and Field Data Forms
C........................ Certified AHERA Building Inspector Certificates
D ....................... Laboratory Certifications for Asbestos and Lead Analysis
E ........................ Sample Location Drawings for Asbestos, Lead, and TCLP
F ........................ Lead TCLP Laboratory Reports and Field Data Forms
G ....................... Abatement Cost Estimate iv
ACRONYM LIST
ACM.......................Asbestos-Containing Material
ACT ....................... Acoustic Ceiling Tile AHERA ................... Asbestos Hazard Emergency Response Act
AIHA ...................... American Industrial Hygiene Association CFL ........................ Compact Fluorescent Light
CFR ....................... Code of Federal Regulations
CMU .......................Concrete Masonry Unit DOSH.....................Washington State Department of Labor and Industries, Division of
Occupational Safety and Health EA ......................... Each
Ecology .................. Washington State Department of Ecology EHSI ...................... EHS-International, Inc.
ELLAP .....................Environmental Lead Laboratory Accreditation Program FRP........................Fiberglass Reinforced Panels
GWB ...................... Gypsum Wall Board
Hg ......................... Mercury HID........................High Intensity Discharge
JC..........................Joint Compound LCM ....................... Lead-Containing Material
LCP........................Lead-Containing Paint LF..........................Linear Feet
L&I ........................ Washington State Department of Labor and Industries mg/cm2 .................. Milligrams Per Square Centimeter mg/L......................Milligrams Per Liter
N/A ........................Not Applicable ND.........................None Detected
NVL ....................... NVL Laboratories, Inc.
NVLAP .................... National Voluntary Laboratory Accreditation Program
OSHA ..................... US Occupational Safety and Health Administration ORCAA ................... Olympic Region Clean Air Agency
Pb ......................... Lead PCBs ...................... Polychlorinated Biphenyls
PLM ....................... Polarized Light Microscopy ppm.......................Parts per Million QA ......................... Quality Assurance
RCW ...................... Revised Code of Washington SAT ....................... Seattle Asbestos Test, LLC
SF ......................... Square Feet SVF........................Sheet Vinyl Flooring
TCLP ...................... Toxicity Characteristic Leaching Procedure VAT ....................... Vinyl Asbestos Tile
VCT ....................... Vinyl Composite Tile
WAC ...................... Washington Administrative Code WT ........................ Weight w/ ......................... With XRF ....................... x-ray fluorescence
NPS – Lake Quinault - Hoiness Property
EHSI Project 11035 November 21st, 2017
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
The National Park Service (NPS) plans to demolish the existing structures on the Hoiness
Property located on Lake Quinault at 604 North Shore Road, Amanda Park, Washington. The NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Hoiness Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure (TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl (PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:
interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.
1.3 ACM MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOINESS PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION
Non-ACM tan SVF (w/ wood pattern) w/ non-ACM black rubber backing w/ non-ACM black/clear mastic w/ non-ACM black rubber backing on 9”x9” tan VAT w/ non-ACM beige mastic on wood [Sample # 02]
Hallway and south Entry
Wood wall panels w/ ACM black mastic on plywood [Sample # 27 &
27QA]
Kitchen
ACM white woven mat (behind metal trim of fireplace) [Sample # 49] Living Room
ACM brown wall penetration sealant (on 1” & 3” OD wall penetrations below sink) [Sample # 54] Bathroom #1
KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, OD = outside diameter, SVF = sheet vinyl flooring, VAT = vinyl asbestos tile, w/ = with
1.4 OPINIONS AND RECOMMENDATIONS
The project includes demolition of the existing structures at the Hoiness Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.
EHSI Project 11035 November 21st, 2017
Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).
No fluorescent light fixtures were found to have magnetic ballasts which are assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. No Hg-containing fluorescent light tubes, CFL bulbs, or HID lamps were found on-site during the inspection; any fluorescent tubes/bulbs/lamps found during demolition must be recycled as (Ecology) Universal Waste.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. This report and accompanying appendices include the supporting information for this executive summary.
EHSI Project 11035 November 21st, 2017
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
The NPS plans to demolish the existing structures at the Hoiness Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:
identification of all suspect materials; a determination of whether suspect materials were:
ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.
On October 11th, 12th, and 18th, 2017, EHSI conducted a Limited Lead and Asbestos Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region
Clean Air Agency (ORCAA).
2.2 BUILDING DESCRIPTION
The Hoiness Property is located on Lake Quinault at 604 North Shore Road, Amanda Park, Washington. Structures on the property include a single-story single occupancy residential house, two detached storage sheds, a large, high bay boat storage shed, and a detached garage located on the opposite side of North Shore Drive directly across from the Hoiness Property driveway.
The residence is a wood-framed structure with a concrete masonry unit (CMU) foundation posts and red brick or wood siding. The roof has layering of 3-tab under a sheet metal roofing.
Interior floor finishes include: sheet vinyl flooring (SVF), 9”x9” vinyl composite tile (VCT), SVF on 9”x9” vinyl asbestos tile (VAT), 16”x16” VCT, 12”x12” ceramic floor tiles, and carpet.
Interior wall finishes include: wood wall panels, gypsum wallboard (GWB), laminated wood fiber reinforced paneling (FRP), metal paneling, and brick. Interior ceiling finishes include:
GWB, 1’x1’ acoustical ceiling tiles (ACT), FRP, and metal paneling. Windows are vinyl-framed and operable. Hot water was provided by an electric domestic hot water tank. Heating was formerly provided by a wood fireplace in the residence. Floor vents indicate the possibility of an oil furnace being formerly installed in the residence, however no furnace was observed.
Interior lighting consists of incandescent and natural light from the windows.
The two sheds east of the residence consist of wood walls and siding. Both sheds have a metal roof over wood and no electricity or plumbing. The high bay boat shed is a wood frame structure with sheet metal siding and roof, with no electricity or plumbing. The garage is a wood-framed structure with a concrete slab foundation and wood exterior.
EHSI Project 11035 November 21st, 2017
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix
C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October
1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and
Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary
Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.
Copies of both laboratories’ NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used an Olympus Delta-Pro x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial
Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program (ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Seventy-four (74) bulk samples of suspect ACM were collected as part of the survey. Four (4) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, EHSI Project 11035 November 21st, 2017 material description, sample location, and analytical results are summarized in Table 1. The
ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. All suspect materials were accessible for sampling.
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-01
Living Room
Layer 1: Tan SVF (w/ wood pattern)
Layer 2: Black vinyl backing
Layer 3: Black/clear mastic Layer 4: Black rubber backing
Layer 5: Clear/brown/black brittle mastic
Layer 6: Hardwood flooring Layer 7: Brown paper vapor barrier w/ black mastic Layer 8: Black asphaltic vapor barrier (on wood subfloor)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
L8: ND
N/A
N/A
N/A N/A
N/A
N/A N/A
N/A
11035-
HOI-02
Hall
Layer 1: Tan SVF (w/ wood pattern)
Layer 2: Black vinyl backing
Layer 3: Black/clear mastic Layer 4: Black rubber backing
Layer 5: 9”x9” Tan VAT Layer 6: Beige mastic
Layer 7: Plywood subfloor
L1: ND
L2: ND
L3: ND
L4: ND
L5: 2%
L6: ND
L7: ND
N/A
N/A
N/A N/A
Chrysotile N/A
N/A
11035-
HOI-03
West
Bedroom
Layer 1: 9”x9” Beige VCT Layer 2: Black mastic
Layer 3: Brown paper vapor barrier
Layer 4: Black asphaltic tar Layer 5: Brown paper vapor barrier (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A N/A
N/A
N/A N/A
11035-
HOI-04
Center
Bedroom
Layer 1: 9”x9” Green VCT Layer 2: Brown mastic
Layer 3: Plywood subfloor
L1: ND
L2: ND
L3: ND
N/A N/A
N/A
11035-
HOI-05
Kitchen
Layer 1: Tan SVF (w/ wood pattern)
Layer 2: Black vinyl backing
Layer 3: Black/clear mastic Layer 4: Black rubber backing
Layer 5: Black soft material Layer 6: White mastic
Layer 7: Brown/clear mastic Layer 8: Hardwood
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
L8: ND
N/A
N/A
N/A N/A
N/A N/A
N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-
06QA
Master
Bedroom
Layer 1: 9”x9” Brown VCT (w/ white streaks)
Layer 2: Black mastic Layer 3: Plywood subfloor
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-
HOI-07
Bathroom
#1
Layer 1: White paint
Layer 2: 9”x9” Dark green/brown
VCT
Layer 3: Black mastic Layer 4: Plywood subfloor
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A N/A
11035-
HOI-08
Sunroom
Layer 1: 16”x16” Tan VCT
Layer 2: Green fibrous backing Layer 3: Tan/beige SVF
Layer 4: Green foam pad (on plywood subfloor)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
HOI-09
Mudroom
Layer 1: Tan carpet
Layer 2: White woven fibrous backing Layer 3: Light tan mastic
Layer 4: White woven backing Layer 5: Green foam pad (on plywood subfloor)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A
N/A
N/A N/A
11035-
HOI-10
Mudroom
Layer 1: 12”x12” Beige ceramic floor tiles
Layer 2: Red grout Layer 3: Light gray mortar (on concrete)
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-
HOI-11
Laundry Room Hall
Layer 1: Off-white SVF (w/ raised square pattern)
Layer 2: Gray paper backing Layer 2: Beige mastic
Layer 3: Wood
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
HOI-12
Sunroom Light gray putty (between 16”x16” tan VCT and brick wall)
ND N/A
11035- HOI-131 Living Room
Layer 1: Tan troweled on texturing w/ paint Layer 2: GWB wall w/ paper(mid-wall)
L1: 0.5%
L2: ND
Chrysotile
N/A
11035-
HOI-141 Living Room
Layer 1: Tan troweled on texturing w/ paint and paper
Layer 2: GWB wall w/ paper
(corner)
L1: 0.25%
L2: ND
Chrysotile
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-15
Living Room
Layer 1: White troweled on texturing w/ paint
Layer 2: GWB ceiling w/ paper (mid-ceiling)
L1: ND
L2: ND
N/A
N/A
11035- HOI-161 Kitchen
Layer 1: Light blue plaid wallpaper Layer 2: White wallpaper
Layer 3: Yellow skim coat w/ paint
Layer 4: Off-white skim coat
Layer 5: GWB wall w/ paper (mid-wall)
L1: ND
L2: ND
L3: 0.25%
L4: 0.5%
L5: ND
N/A
N/A
Chrysotile
Chrysotile
N/A
11035- HOI-171 Hall
Layer 1: Yellow skim coat w/ paint Layer 2: Off-white skim coat
Layer 3: GWB wall w/ paper (corner)
L1: 0.5%
L2: 0.25%
L3: ND
Chrysotile
Chrysotile
N/A
11035-
HOI-181 Kitchen
Layer 1: Yellow skim coat w/ paint Layer 2: Thick off-white skim coat w/ paper Layer 3: GWB ceiling w/ paper
(mid-ceiling)
L1: 0.5%
L2: 0.5%
L3: ND
Chrysotile
Chrysotile
N/A
11035- HOI-191 Hall
Layer 1: Yellow skim coat w/ paint (on thick off-white skim coat) Layer 2: GWB wall w/ paper
(mid-wall)
L1: 0.75%
L2: ND
Chrysotile
N/A
11035- HOI-201 Kitchen
Layer 1: Trace yellow skim coat w/ paint
Layer 2: Off-white skim coat
Layer 3: GWB ceiling w/ paper (mid-ceiling)
L1: 0.5%
L2: 0.5%
L3: ND
Chrysotile
Chrysotile
N/A
11035-
HOI-211 Kitchen
Layer 1: Yellow skim coat w/ paint Layer 2: Trace off-white skim coat Layer 3: GWB w/ paper (mid-ceiling)
L1: 0.75%
L2: 0.5%
L3: ND
Chrysotile
Chrysotile
N/A
11035-
HOI-221
Center
Bedroom
Layer 1: Off-white rough texturing w/ paint
Layer 2: Off-white JC w/ paper Layer 3: GWB wall w/ paper
(corner)
L1: 0.25%
L2: 0.25%
L3: ND
Chrysotile
Chrysotile
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-231
Center
Bedroom
Layer 1: Off-white rough texturing w/ paint
Layer 2: GWB ceiling w/ paper (mid-ceiling)
L1: 0.25%
L2: ND
Chrysotile
N/A
11035-
HOI-241
Center Bedroom
Layer 1: Off-white rough texturing w/ paint Layer 2: GWB wall w/ paper
(mid-wall)
L1: 0.25%
L2: ND
Chrysotile
N/A
11035-
HOI-251
Bathroom #1
Layer 1: White thin SVF Layer 2: Dark brown fiberboard
Layer 3: Orange mastic Layer 4: Beige leveling compound
(on plywood)
L1: ND
L2: ND
L3: ND
L4: 0.25%
N/A N/A
N/A Chrysotile
11035-
HOI-26
Living Room
Deck Entry
Layer 1: Beige mastic Layer 2: Wood wall panel
Layer 3: Brown fiberboard
L1: ND
L2: ND
L3: ND
N/A N/A
N/A
11035-
HOI-
27QA1
Kitchen
Layer 1: Black mastic w/ paint behind
Layer 2: Wood wall panels (on plywood)
L1: 1.5%
L2: ND
Chrysotile
N/A
11035-
HOI-28
Sunroom
Black asphaltic vapor barrier (on unfinished plywood walls)
ND N/A
11035-
HOI-29
Sunroom
Layer 1: Painted aluminum sheet metal
Layer 2: Trace light gray/clear mastic Layer 3: White styrofoam insulation
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOI-30
Kitchen
Layer 1: White/brown FRP countertops and backsplash (w/ gold flecks) Layer 2: Brown mastic
Layer 3: Wood
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOI-31
Mudroom
Layer 1: Textured surfacing w/ paint
Layer 2: GWB ceiling w/ paper (mid ceiling)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-32
Mudroom
Layer 1: Textured surfacing w/ paint Layer 2: White JC w/ paper
Layer 3: GWB wall w/ paper (corner)
L1: ND
L2: ND
L3: ND
N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-33
Mudroom
Layer 1: Trace textured surfacing w/ paint
Layer 2: GWB wall w/ paper (mid-wall)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-34
West
Bedroom
Layer 1: Black fiberglass batt insulation Layer 2: Black mastic
Layer 3: Trace black fiberglass insulation
Layer 4: Silver foil vapor barrier
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-
HOI-35
Mudroom
Layer 1: Yellow fiberglass batt insulation
Layer 2: Black mastic
Layer 3: Brown paper vapor barrier
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOI-36
Mudroom
Layer 1: Trace white rough texturing w/ paint Layer 2: GWB wall w/ paper
(mid-wall)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-37
Laundry/ Bathroom
#2 Hall
Layer 1: Trace white rough texturing w/ paint and paper
Layer 2: GWB ceiling w/ paper (corner)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-38
West Bedroom
Layer 1: Pink/silver foil
Layer 2: Trace white mastic Layer 3: White woven mesh backing (applied around all windows)
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-
HOI-39
West
Bedroom
Layer 1: Clear plastic
Layer 2: Silver foil Layer 3: Off-white mastic
Layer 4: Woven white mesh backing (applied around all windows)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-
HOI-40
Sunroom
Black/brown caulking (between metal wall panels and 16”x16” tan VCT)
ND N/A
11035-
HOI-41
Kitchen
Layer 1: Light gray window frame caulking Layer 2: 6’x3’ Tan vinyl window frame
L1: ND
L2: ND
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-42
Sunroom
Layer 1: Black asphaltic vapor barrier
Layer 2: Clear plastic Layer 3: Silver foil
Layer 4: Trace off-white mastic Layer 5: Woven white mesh backing
Layer 6: Black asphaltic vapor barrier
Layer 7: Trace wood (throughout exterior brick walls)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
N/A
N/A N/A
N/A N/A
N/A
N/A
11035-
HOI-43
Sunroom
Metallic dark brown/black sealant
(around metal door trim)
ND N/A
11035-
HOI-44
Sunroom Black seam sealant (along top of metal-framed windows)
ND N/A
11035-
HOI-45
Living Room
White window glazing putty (on
4’x12’ vinyl-framed windows)
ND N/A
11035-
HOI-46
Living Room
Layer 1: Light gray window frame caulking
Layer 2: Wood debris
L1: ND
L2: ND
N/A
N/A
11035-
HOI-47
Living Room
Deck Entry
Layer 1: Tan stain on off-white window glazing putty
Layer 2: Wood window frame (in wood door)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-
48QA
Hall
Layer 1: 1’x1’ ACT w/ paint and gold accents (w/ pinhole pattern) Layer 2: Beige glue dots w/paint
Layer 3: Brown GWB paper
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOI-49
Living Room
White woven mat w/ paint (behind metal trim of fireplace)
28% Chrysotile
11035-
HOI-50
Living Room
Deck Entry
Layer 1: 1’x1’ ACT w/ paint and gold accents
Layer 2: Brown glue dots (on plywood)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-51
Bathroom #1
Layer 1: White laminate on dark brown fiberboard Layer 2: Orange mastic (on wood)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-52
Kitchen Black rubber sink drain gasket (on cast iron sink)
ND N/A
11035-
HOI-53
Bathroom
#1
Black rubber sink drain gasket
(on ceramic sink)
ND N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-54
Bathroom #1
Brown wall penetration sealant (on 1” & 3” OD wall penetrations below sink)
2% Chrysotile
11035-
HOI-55
Kitchen
Layer 1: Black pipe dope Layer 2: Trace remnant off-white pipe dope (on 1” & 3” OD metal pipe fittings)
L1: ND
L2: ND
N/A N/A
11035-
HOI-56
Bathroom #2
Layer 1: Off-white mastic
Layer 2: White JC w/ paint (around fiberglass reinforced shower)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-57
Laundry Room
Gray pipe dope (on 1” OD pipe fittings to water heater)
ND N/A
11035-
HOI-58
Attic
Layer 1: Pink fiberglass insulation
Layer 2: Black mastic Layer 3: Brown/red paper vapor barrier (around skylights)
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-
HOI-59
Exterior Layer 1: Red brick Layer 2: Gray mortar
L1: ND
L2: ND
N/A N/A
11035-
HOI-60
Living Room
Layer 1: Red brick w/ paint
Layer 2: Gray mortar w/ paint
L1: ND
L2: ND
N/A
N/A
11035-
HOI-61
Exterior Black window glazing gasket (on 4’x4’ vinyl-framed windows)
ND N/A
11035-
HOI-62
Exterior
Layer 1: Trace black asphaltic tar
Layer 2: Black asphaltic vapor barrier
Layer 3: Black asphaltic 3-tab roofing w/ white sand granules
Layer 4: Black asphaltic vapor barrier (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-
HOI-63
Exterior
Layer 1: Off-white window frame caulking (on 2’x2’ vinyl-framed windows)
Layer 2: White/tan fibrous material
L1: ND
L2: ND
N/A
N/A
11035-
HOI-64
Exterior
Black seam sealant (on all sheet metal seams on Sun Room)
ND N/A
11035-
HOI-
65QA
Exterior Black asphaltic vapor barrier (behind wood siding & between brick façade and wood siding)
ND N/A
11035-
HOI-66
Exterior Layer 1: Gray CMU Layer 2: Light gray mortar
L1: ND
L2: ND
N/A N/A
11035-
HOI-67
Small Shed
Thick black asphaltic vapor barrier (from roll in shed)
ND N/A
EHSI Project 11035 November 21st, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOINESS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOI-68
Small Shed Thin black asphaltic vapor barrier (from roll in shed)
ND N/A
11035-
HOI-69
Behind
Sheds
Layer 1: Black rubber mat layer
Layer 2: White/gray woven threading
Layer 3: Black rubber mat layer Layer 4: White/gray woven threading Layer 5: Black rubber mat layer
Layer 6: White/gray woven threading Layer 7: Black rubber mat layer
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
N/A
N/A
N/A N/A
N/A
N/A
N/A
11035-
HOI-70
Detached High Bay
Carport
Layer 1: Black asphaltic vapor barrier Layer 2: Black asphaltic vapor barrier (beneath sheet metal roofing on plywood)
L1: ND
L2: ND
N/A
N/A
11035-
HOI-71
Laundry
Room
Black electrical breaker component (in 1’x2’ electrical panel)
ND N/A
11035-
HOI-
101817-
Detached Garage
Layer 1: Clear/green plastic vapor barrier Layer 2: Wood siding
L1: ND
L2: ND
N/A
N/A
11035-
HOI-
101817-
Detached
Garage
Black electrical panel components
(in 14”x18” electrical panel)
ND N/A
KEY: ACT = acoustic ceiling tile, bold = bold text indicates asbestos-containing layer, CMU = concrete masonry unit, FRP = fiberglass reinforced panels, GWB = gypsum wall board, JC =joint compound, ND = non-detect, N/A = not applicable, OD = outside diameter, SVF = sheet vinyl flooring, VAT = vinyl asbestos tile, VCT = vinyl composite tile, w/ = with
1 Point Counted Results. Preliminary analytical reports indicated that nineteen (19) sample layers contained approximately 2-3% chrysotile asbestos (Sample #s 11035-HOI-13, 14, 16- 25, and 27). EHSI re-submitted the samples reported to have greater than 1% asbestos concentration for re-analysis using the more precise EPA “Point Count” method. The “Point Count” analytical method is recommended by the EPA for samples with less than 10% asbestos.
Based on the results of that re-analysis, materials found to contain less than 1% (<1%) asbestos were determined to be a non-ACM (e.g., containing < 1% asbestos fibers) and are therefore not ACM. Materials found to contain greater than 1% asbestos are identified and quantified in Table 2 of this report. Only the “Point Count” re-analysis concentrations are listed in Table 1. Analytical results for all analyses are provided in Appendix A.
EHSI Project 11035 November 21st, 2017
Materials containing <1% asbestos fibers are considered a non-ACM and are not regulated for disposal purpose. However, removal of <1% asbestos materials are considered an unclassified asbestos operation by DOSH. As directed by WRD 23.30, for all other demolition of materials with <1% asbestos, employees shall have received at least two hours of asbestos awareness training as specified L&I DOSH Instruction WAC 296-62-07722(5).
Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2
Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOINESS PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
Non-ACM tan SVF (w/ wood pattern) w/ non-ACM black rubber backing w/ non-ACM black/clear mastic w/ non-
ACM black rubber backing on 9”x9” tan VAT w/ non- ACM beige mastic on wood [Sample # 02]
Hallway and south
Entry
100 SF
Wood wall panels w/ ACM black mastic on plywood
[Sample #s 27 & 27QA] Kitchen 300 SF
ACM white woven mat (behind metal trim of fireplace) [Sample # 49] Living Room 16 SF
ACM brown wall penetration sealant (on 1” & 3” OD wall penetrations below sink) [Sample # 54]
Bathroom #1 3 LF
KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, LF = linear feet, OD = outside diameter, SF = square feet, SVF = sheet vinyl flooring, VAT = vinyl asbestos tile, w/ = with
ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect
ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building
Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.
2.4.2 Lead-Containing Paint and Building Materials
Sixty-seven (67) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer. XRF paint sample results ranged from greater than or equal to 5.0 milligrams of lead per square centimeter (mg Pb/cm2) to 0 mg Pb/cm2. Bolded results indicate materials coated with “lead-based paint” (e.g., >1.0 mg/cm2) as defined by USEPA regulation
40CFR745 and Washington State Commerce regulation WAC 365-230. The results are provided in Table 3 of this report.
EHSI Project 11035 November 21st, 2017
Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOINESS PROPERTY
Read
Component Substrate Color Building Room
Lead
Conc.
(mg/cm2)
1 NIST Check Metal Red N/A N/A 1.08
2 NIST Check Metal Red N/A N/A 1.06
3 NIST Check Metal Red House Livingroom 1.12
4 Wall Wood White House Livingroom < LOD
5 Fireplace Mantle CMU Brick White House Livingroom < Lod
6 Fireplace Mantle CMU Brick White House Livingroom < Lod
7 Wall Drywall White House Livingroom < LOD
8 Wall Drywall White House Hall < LOD
9 Wall Drywall White House Hall Closet < LOD
10 Ceiling Fiber Board White House Bedroom < LOD
11 Wall Drywall White House Bedroom < LOD
12 Wall Drywall Light Blue House Bedroom < LOD
13 Wall Paneling Wood Light Brown House Hall 0.01
14 Wall Drywall Light Brown House Bathroom < LOD
15 Wall Plastic White House Bathroom < LOD
16 Sink Ceramic White House Bathroom < LOD
17 Toilet Base Ceramic Dark Gray House Shower < Lod
18 Wall Fiber Board White House Shower < LOD
19 Wall Plastic Light Gray House Bathroom < LOD
20 Door Trim Wood Off White House Bathroom < Lod
21 Door Trim Wood Off White House Kitchen < Lod
22 Wall Drywall Yellow House Kitchen 0.08
23 Door Frame Drywall White House Kitchen 0.01
24 Counter Fiber Board White House Kitchen < LOD
25 Wall Drywall Light Blue House Kitchen 0.25
26 Sink Ceramic White House Kitchen >5.0
27 Sink Ceramic White House Kitchen >5.0
28 Sink Ceramic White House Kitchen >5.0
29 Attic Door Hatch Wood White House Sunroom < Lod
30 Wall Brick Red House Sunroom < LOD
EHSI Project 11035 November 21st, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOINESS PROPERTY
31 Wall Mortar Red House Sunroom < LOD
32 Window Frame Metal Purple House Sunroom < Lod
33 Wall Skirt Metal Brown House Sunroom < Lod
34 Floor Plastic Pink House Sunroom < LOD
35 Window Trim Concrete Light Gray House Mud Room < Lod
36 Wall Drywall Yellow House Mud Room < LOD
37 Door Trim Wood Brown House Shower < Lod
38 Wall Plastic White House Mud Room < LOD
39 Floor Ceramic Pink House Mud Room < LOD
40 Door Metal White House Mud Room < LOD
41 Door Trim Wood Brown House Mud Room < Lod
42 Door Trim Wood Brown House Exterior < Lod
43 Window Frame Wood White House Exterior < Lod
44 Wall Wood Red House Exterior 0.69
45 Wall Wood Red House Exterior < LOD
46 Wall Brick Red House Exterior < LOD
47 Downspout Metal Brown House Exterior < LOD
48 Soffit Wood Red House Exterior < LOD
49 Window Frame CMU Brick Light Gray House Exterior < Lod
50 Wall Wood Light Brown House Exterior 0.02
51 Soffit Wood Light Blue House Exterior < LOD
52 Soffit Metal White House Exterior < LOD
53 Window Frame CMU Brick Light Gray House Exterior < Lod
54 Structural Beam Wood Red House Exterior 0.05
55 Structural Beam CMU Brick Gray House Exterior < Lod
56 Wall Brick Red Storage Sheds Outbuilding 1
Ext
< LOD
57 Wall Wood Light Blue Storage Sheds Outbuilding 1
Ext 0.24
58 Wall Wood Red Storage Sheds Outbuilding 1
Ext 0.26
59 Door Trim Wood White Storage Sheds Outbuilding 1
Ext < Lod
60 Door Trim Wood Light Gray Storage Sheds Outbuilding 1
Ext < Lod
61 Floor Concrete Light Gray Storage Sheds Outbuilding 2
Ext
< LOD
62 Wall Metal Light Blue Storage Sheds Outbuilding 2
Ext 0.01
EHSI Project 11035 November 21st, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOINESS PROPERTY
63 Wall Trim Metal White Storage Sheds Outbuilding 2
Ext 0.01
64 NIST Check drywall Red N/A N/A 1.07
65 NIST Check drywall Red N/A N/A 1.08
66 NIST Check drywall Red N/A N/A 1.01
67 NIST Check drywall Red N/A N/A 1.1
Key: CMU = concrete masonry unit, N/A = not applicable, In addition to the XRF samples, EHSI collected four (4) bulk QA samples for laboratory analysis. The bulk sample results were less than the reporting limit. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations. Note: Two (2) lead vent pipes were observed on the roof of the property.
Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.
Copies of the analytical laboratory report and field data forms for lead paint are included in
Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOINESS PROPERTY
SAMPLE
NUMBER
LOCATION
COMPONENT/
SUBSTRATE
COLOR
RESULTS
% Pb by
WT
11035-HOI-
Pb01
House, Mudroom Ceramic tile with mortar and grout
Red/Gray <0.0043
11035-HOI-
Pb02 House, Exterior Wall Brick and mortar Red <0.0033
11035-HOI-
Pb03
House, Foundation CMU and mortar Gray <0.0043
11035_HOI-
Pb04
House, Living Room
Fireplace Brick and mortar Red <0.0023
Key: CMU = concrete masonry unit, Pb = lead, WT = weight
DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.
EHSI Project 11035 November 21st, 2017
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).
At the request of NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos
Survey. The results of that lead-TCLP analysis indicate no leachable lead was present in the anticipated demolition waste stream above the laboratories reporting limit at a concentration of <0.5 mg/L. A detailed list of the materials included in the TCLP sample are provided in Appendix F.
It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.
2.4.4 Polychlorinated Biphenyls
Ballasts EHSI inspected the building for fluorescent fixture than may have PCB-containing ballasts. No fixtures were found on-site.
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
No fluorescent light tubes, CFL bulbs, or HID lamps were found at the Hoiness Property. Hg wastes are regulated as “universal wastes” under Ecology’s regulation WAC 173-303. If any
Hg-containing building materials are found on-site they must be recycled or disposed of as hazardous waste. No Hg-containing thermostats were identified at the Hoiness Property.
3.0 LIMITATIONS
This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished. All suspect materials present were accessible for sampling.
This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be ACM by this survey report when encountered must be treated as ACM until sampled by a
Certified AHERA Building Inspector and analyzed by a certified laboratory.
EHSI Project 11035 November 21st, 2017
4.0 STANDARD OF CARE
The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.
5.0 CERTIFIED AHERA BUILDING INSPECTORS
The Certified AHERA Building Inspectors listed below surveyed on October 11th, 12th, and 18th, 2017, in accordance with federal, state, and local requirements.
Rory Peterson Mike Ruark
Certified AHERA Building Inspector Certified AHERA Building Inspector Certificate Number: 1628987 Certificate Number: 163007
Expiration Date: August 23, 2018 Expiration Date: September 6, 2018
Tim Nickell Micki Towler
Certified AHERA Building Inspector Certified AHERA Building Inspector Certificate Number: 1628878 Certificate Number: 154608
Expiration Date: August 10, 2018 Expiration Date: December 9, 2017
Appendix A
APPENDIX A
Asbestos Analytical Laboratory Report and Field Data Forms
Nick Ly, Technical Director
Client Project: 11035-02
Location: Hoiness Property
Dear Mr. Peterson, Enclosed please find test results for the 4 sample(s) submitted to our laboratory for analysis on
10/18/2017.
Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116
Method for the Determination of Asbestos in Bulk Building Materials.
For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.
For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.
The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results
October 24, 2017
Nick L T hnical D
Rory Peterson
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1718549.00
< Client:
Address:
Attention: Mr. Rory Peterson
Hoiness Property
Client Project #: 11035-02
Samples Received: 4
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 4
Project Location:
Batch #: 1718549.00
Date Received: 10/18/2017
17101315Lab ID: Client Sample #:
Location: Hoiness Property
11035-HOI-06QA
Layer 1 of 2 Description: Brown vinyl tile
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Vinyl/Binder, Mineral grains 2%Cellulose None Detected ND
Layer 2 of 2 Description: Black asphaltic mastic (on wood)
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Wood flakes 3%Wood fibers None Detected ND
2%Cellulose
17101316Lab ID: Client Sample #:
Location: Hoiness Property
11035-HOI-27QA
Layer 1 of 2 Description: Black brittle mastic with trace paint
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Mastic/Binder, Paint 2%Cellulose Chrysotile 2%
Layer 2 of 2 Description: Brown fibrous material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler 67%Cellulose None Detected ND
17101317Lab ID: Client Sample #:
Location: Hoiness Property
11035-HOI-48QA
Layer 1 of 2 Description: Tan compressed fibrous material with paint
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Paint, Wood flakes 61%Cellulose None Detected ND
14%Wood fibers
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Lori TsengAnalyzed by:
Nick LyReviewed by:
10/23/2017 Date:
10/24/2017Date:
Sampled by:
< Client:
Address:
Attention: Mr. Rory Peterson
Hoiness Property
Client Project #: 11035-02
Samples Received: 4
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 4
Project Location:
Batch #: 1718549.00
Date Received: 10/18/2017
Layer 2 of 2 Description: Beige brittle mastic with paper
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Mastic/Binder, Binder/Filler 21%Cellulose None Detected ND
17101318Lab ID: Client Sample #:
Location: Hoiness Property
11035-HOI-65QA
Layer 1 of 1 Description: Black asphaltic fibrous material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Binder/Filler 67%Cellulose None Detected ND
2%Spider silk
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Lori TsengAnalyzed by:
Nick LyReviewed by:
10/23/2017 Date:
10/24/2017Date:
Sampled by:
EHS International 1718549.00
Company NVL Batch Number
Total Number of Samples
Hoiness Property
5 DaysTAT
10/25/2017Due Date 9:40 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-02Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals
ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-HOI-06QA1 A17101315
11035-HOI-27QA2 A17101316
11035-HOI-48QA3 A17101317
11035-HOI-65QA4 A17101318
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Lori TsengAnalyzed by
Results Called by
NVL
NVL
10/18/17
10/23/17
Print Name
Entered By: Mohammed Jamal
Date: 10/18/2017
Time: 12:54 PM
Special
Instructions:
RE: Bulk Asbestos Fiber Concentration by Point Count
NVL Batch # 1720567
Client Project: 11035-02
Location: Hoiness Property
Dear Mr. Peterson, At your request, NVL Laboratories conducted analysis of your sample to determine the asbestos concentration using point count procedures.
The sample was analyzed for the presence of asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with U.S. EPA method 600/R
-93/116.
Eight slides of thoroughly homogenized material are prepared for any given sample that requires point counting. In order to be counted as a point, the crosshairs of the microscope must center on either a fiber or a particle. The analyst counts at least 50 points per slide preparation. A minimum of 400 non-empty points are counted, then the number of counted asbestos fibers are divided by the total number of points counted to arrive at the percentage of asbestos in the sample.
Please see the conclusion section of the lab reports for point count results.
It has been a pleasure to be of service to you. Please feel free to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results Lab Code:102063
November 17, 2017
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Rory Peterson
EHS International
Bulk Asbestos Fibers Analysis PLM Point Count
1 Client:
Address:
Attention: Mr. Rory Peterson
Hoiness Property
Client Project #: 11035-02
Samples Received: 1
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600R-93/116
Samples Analyzed: 1Project Location:
Batch #: 1720567.00
Date Received: 11/14/2017
Prep
Slide #
Asbestos
Point
Non
Asbestos
Point
6 394
Total
Points
Counted
17112971Lab ID : 11035-HOI-27QA layer 1Client Sample #:
Black brittle mastic with trace paint, Layer 1 of 2
Introduction:
This sample was initially analyzed for Asbestos content using Polarized Light Microscopy (PLM).
Asbestos fibers were observed and quantity was determined using calibrated visual area estimation.
Asbestos content was originally found to be 2 % in Layer 1 . Corresponding Lab ID was
17101316
Sample Description:
This Sample Contains 1.5 %…
This is the start of the file's text. The full file is on GovTribe.