Attchmt 10_Tinkham Property Report.pdf
PDF 15 MB Posted
- Attached to
- Hazardous Materials Abatement, OLYM Federal contract opportunity
- Solicitation number
- 140P8318Q0051
About this file
Not Listed
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1011 SW Klickitat Way, Suite 104, Seattle, Washington 98134
Phone 206-381-1128
Toll Free 800-666-2959
Fax 206-254-4279
Environmental Consulting
Hazardous Materials Management
Industrial Hygiene Services
Construction Management
Indoor Air Quality
LIMITED LEAD AND ASBESTOS SURVEY REPORT
NATIONAL PARK SERVICE - OLYMPIC NATIONAL PARK
LAKE CRESCENT - TINKHAM PROPERTY
1324 Camp David Jr. Road
Port Angeles, Washington 98363
November 6th, 2017
Prepared For:
Jeff Doryland
Deputy Chief of Facility Management
Olympic National Park
600 E. Park Avenue, Port Angeles, WA 98273 ii
Limited Lead and Asbestos Survey Report
National Park Service – Olympic National Park
Lake Crescent - Tinkham Property
1324 Camp David Jr. Road
Port Angeles, Washington
EHSI Project No.: # 11035
The material and data in this report were prepared under the supervision and direction of the undersigned.
Rory Peterson
Lead AHERA Building Inspector
Derica Escamilla
Principal of Hazardous Materials
Services iii
TABLE OF CONTENTS
Acronym List .................................................................................... iv
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
1.2 EXTENT OF CURRENT SURVEY
1.3 ACM MATERIALS FOUND
1.4 OPINIONS AND RECOMMENDATIONS
1.5 LIMITATIONS/DISCLAIMER
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
2.2 BUILDING DESCRIPTION
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
2.3.2 Lead-Containing Paint/Lead-Containing Materials
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
2.4.2 Lead-Containing Paint and Building Materials
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
2.4.4 Polychlorinated Biphenyls
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
3.0 LIMITATIONS
4.0 STANDARD OF CARE
5.0 CERTIFIED AHERA BUILDING INSPECTORS
APPENDICES
A........................ Asbestos Laboratory Reports and Field Data Forms
B........................ Lead Laboratory Reports and Field Data Forms
C........................ Certified AHERA Building Inspector Certificates
D ....................... Laboratory Certifications for Asbestos and Lead Analysis
E ........................ Sample Location Drawings for Asbestos, Lead, and TCLP
F ........................ Lead TCLP Laboratory Reports and Field Data Forms
G ....................... Abatement Cost Estimate iv
ACRONYM LIST
ACM.......................Asbestos-Containing Material
AHERA ................... Asbestos Hazard Emergency Response Act AIHA ...................... American Industrial Hygiene Association
CFL ........................ Compact Fluorescent Light CFR ....................... Code of Federal Regulations
DOSH.....................Washington State Department of Labor and Industries, Division of
Occupational Safety and Health EA ......................... Each
Ecology .................. Washington State Department of Ecology EHSI ...................... EHS-International, Inc.
ELLAP .....................Environmental Lead Laboratory Accreditation Program GWB ...................... Gypsum Wall Board
Hg ......................... Mercury JC..........................Joint Compound
LCM ....................... Lead-Containing Material
LCP........................Lead-Containing Paint L&I ........................ Washington State Department of Labor and Industries mg/cm2 .................. Milligrams Per Square Centimeters mg/L......................Milligrams Per Liter
N/A ........................Not Applicable ND.........................None Detected
NVL ....................... NVL Laboratories, Inc.
NVLAP .................... National Voluntary Laboratory Accreditation Program
OSHA ..................... US Occupational Safety and Health Administration
ORCAA ................... Olympic Clean Air Agency Pb ......................... Lead
PCBs ...................... Polychlorinated Biphenyls PLM ....................... Polarized Light Microscopy ppm.......................Parts per Million QA ......................... Quality Assurance
RCW ...................... Revised Code of Washington SAT ....................... Seattle Asbestos Test, LLC
SVF........................Sheet Vinyl Flooring
TCLP ...................... Toxicity Characteristic Leaching Procedure WAC ...................... Washington Administrative Code
WT ........................ Weight w/ ......................... With
XRF ....................... x-ray fluorescence
NPS – Lake Crescent - Tinkham Property
EHSI Project 11035 November 6th, 2017
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
The National Park Service (NPS) plans to demolish the existing structures on the Tinkham
Property located on Lake Crescent at 1324 Camp David Jr. Road, Port Angeles, Washington.
The NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Tinkham Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure (TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl (PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:
interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.
1.3 ACM MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION
1’3”x2’6” Electrical panel w/ assumed ACM internal components Garage Interior, NE corner KEY: ACM = asbestos containing material, w/ = with,
1.4 OPINIONS AND RECOMMENDATIONS
The project includes demolition of the existing structures at the Tinkham Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.
Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the
EHSI Project 11035 November 6th, 2017 type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).
Fluorescent light fixtures inspected have magnetic ballasts which are assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. Magnetic ballasts must be removed from fixtures and disposed of as Washington Department of Ecology (Ecology)
Dangerous Waste. All fluorescent tubes and bulbs contain mercury; any fluorescent tubes/bulbs to be disturbed during the project must be recycled as (Ecology) Universal Waste.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. Energized electrical panels were not sampled but were assumed to have ACM internal components based on the inspector’s experience with similar systems on other projects. This report and accompanying appendices include the supporting information for this executive summary.
EHSI Project 11035 November 6th, 2017
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
The NPS plans to demolish the existing structures at the Tinkham Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:
identification of all suspect materials; a determination of whether suspect materials were:
ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.
On September 26th, 2017, EHSI conducted a Limited Lead and Asbestos Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of
Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region
Clean Air Agency (ORCAA).
2.2 BUILDING DESCRIPTION
The Tinkham Property is located on Lake Crescent at 1324 Camp David Jr. Road, Port Angeles, Washington. Structures on the property include a one-story single occupancy residential house w/ loft and partially finished basement, a detached two car garage with covered carport, a small single room lake-side shed, a deteriorating log shack, a small pump house, and two exterior free-standing stone fireplaces.
The house is a wood-framed structure with a concrete foundation and metal roof. Interior floor finishes include: carpet and some ceramic tile, unfinished areas of basement are bare concrete. Interior wall finishes include: GWB and wood paneling in the basement sauna.
Interior ceiling finishes include: GWB and tongue & groove wood planks. Windows are vinyl framed and some but not all are operable. Hot water was provided by an electric domestic hot water tank which has already been removed. Heating was provided by a natural gas furnace which has been removed and moved into the garage. Interior lighting fixtures were removed from the house.
The detached two car garage is a single-story high-bay wood-framed structure with poured concrete slab foundation and metal roofing over the garage and corrugated fiber reinforced roofing panels over the carport. The garage has sheet metal exterior siding and unfinished interior walls and ceiling. The interior had electrical wiring for lighting and garage door openers. There was no heating or plumbing for this structure.
The small lake-side shed has wood framing and wood exterior siding, with a wood shingle roof. Interior floor has SVF on a wood subfloor resting directly on top of bare dirt. There was no electrical, heating, or plumbing for this structure.
EHSI Project 11035 November 6th, 2017
The deteriorating log shack had a partially collapsed roof with wood shingles, log walls and no foundation. Interior floor was dirt. No electric lighting, plumbing or heating is present in this structure.
The small “pump house” is a wood framed structure with wood shingle siding and roof on CMU blocks. No electrical wiring, plumbing or heating were present for this structure. Interior floor, ceiling and walls are unfinished.
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of
Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix
C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October
1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and
Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary
Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.
Copies of both laboratories’ NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used an Olympus Delta-Pro x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial
Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program (ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.
EHSI Project 11035 November 6th, 2017
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Eighty (80) bulk samples of suspect ACM were collected as part of the survey. Four (4) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. Suspect materials not sampled were assumed to be ACM.
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Main Floor, Kitchen
Layer 1: Bumpy white texturing w/ paint and paper Layer 2: GWB wall w/ paper
(corner)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Kitchen /
Dining
Room
Layer 1: Bumpy white texturing w/ paint
Layer 2: GWB wall w/ paint and paper (mid-wall)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Livingroom
Layer 1: Bumpy white texturing w/ paint
Layer 2: GWB wall w/ paint and paper (mid-wall)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Loft
Layer 1: Bumpy white texturing w/ paint Layer 2: GWB wall w/ paint and paper (mid-wall)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Hall
Layer 1: Bumpy white texturing w/ paint
Layer 2: White JC w/ paint Layer 3: GWB wall w/ paper
(corner)
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-TIN-
Main Floor, Master
Bedroom
Layer 1: Bumpy white texturing w/ paint
Layer 2: GWB wall w/ paint and paper (mid-wall)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Walk-in Closet
Layer 1: Trace bumpy white texturing w/ paint Layer 2: White JC w/ paint and paper Layer 3: GWB wall w/ paper
(corner)
L1: ND
L2: ND
L3: ND
N/A
N/A
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Main Floor, Master
Bathroom
GWB wall w/ white paint and paper (mid-wall)
ND N/A
11035-TIN-
Main Floor, Master
Bathroom
Layer 1: White JC w/ white paint and paper
Layer 2: GWB wall w/ paper (corner)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Master Bathroom
GWB wall w/ white paint and paper (mid-wall)
ND N/A
11035-TIN-
Main Floor, Master
Bathroom
Layer 1: Silvery white wall paper Layer 2: Clear mastic
Layer 3: Brown GWB paper w/ paint
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Main Floor, Master
Bathroom
Layer 1: Troweled on white texturing w/ paint and paper Layer 2: GWB ceiling w/ paper
(edge)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Master Bathroom
Layer 1: Troweled on white texturing w/ paint
Layer 2: GWB ceiling w/ paper
(mid-ceiling)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Master
Bedroom
Layer 1: Troweled on white texturing w/ paint
Layer 2: GWB ceiling w/ paper (mid-ceiling)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Kitchen/Dini ng Room
Layer 1: Troweled on white texturing w/ paint Layer 2: White JC w/ paint
Layer 3: GWB ceiling w/ paper (edge)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Main Floor, Kitchen/Dini ng Room
Layer 1: Troweled on white texturing w/ paint Layer 2: GWB ceiling w/ paint and paper (mid-ceiling)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Basement, Room B1
Layer 1: Thick troweled on white texturing w/ paint
Layer 2: GWB wall w/ paper (wall-mid)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Basement, Room B1
Layer 1: Thick troweled on white texturing w/ paint Layer 2: Brown OSB (wall-seam)
L1: ND
L2: ND
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Basement, Room B1
Layer 1: Thick troweled on white texturing w/ paint
Layer 2: Black tape w/ woven backing
Layer 3: Gray mastic (on particle board) (wall-seam)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
20QA
Main Floor, Livingroom
Layer 1: Thick white/gray leveling compound Layer 2: Wood particle board
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Livingroom
Layer 1: Wood particle board
Layer 2: Silver foil Layer 3: Brown paper w/ mastic
Layer 4: Wood subfloor
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-TIN-
Main Floor, Livingroom
Layer 1: Gray/green carpet
Layer 2: White mesh backing
Layer 3: Beige mastic Layer 4: Blue/yellow foam carpet pad (mechanically fastened to wood)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A N/A
11035-TIN-
23QA
Main Floor, Kitchen/Dini ng Room
Layer 1: Gray seam cement
Layer 2: Light gray/gray fibrous underlayment
Layer 3: Black asphaltic vapor barrier (on wood subfloor)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Main Floor, Kitchen/Dini ng Room
Layer 1: 12”x12” Off-white/brown ceramic floor tile Layer 2: White grout
Layer 3: Gray mortar (on Sample 11035-TIN-23)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Main Floor, Kitchen/Dini ng Room
Black asphaltic vapor barrier
(under carpet & particle board on wood subfloor throughout)
ND N/A
11035-TIN-
Main Floor, Livingroom
Layer 1: Trace white texturing w/ paint Layer 2: White door frame caulking w/ paint
Layer 3: Brown paper (on all interior & exterior doors)
L1: ND
L2: ND
L3: ND
N/A
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Main Floor, Master
Bedroom
Layer 1: Trace white texturing w/ paint
Layer 2: White door frame caulking w/ paint
Layer 3: Brown paper (on all interior & exterior doors)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Main Floor, Bathroom
Layer 1: 12”x12” Light gray ceramic tile Layer 2: Gray grout
Layer 3: Pink mortar
Layer 4: Light gray leveling compound (on concrete)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-TIN-
Main Floor, Bathroom
Off-white seam caulking (on tile in Sample 11035-TIN-28 to seal base of toilet)
ND N/A
11035-TIN-
Main Floor, Master Bathroom
Layer 1: 9”x9” White/red ceramic floor tile Layer 2: White grout
Layer 3: Gray mortar Layer 4: Gray/light gray fibrous underlayment (associated w/ tub floor)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A N/A
11035-TIN-
Main Floor, Master Bathroom
Layer 1: 9”x9” White/red ceramic wall tile Layer 2: White grout
Layer 3: White mastic Layer 4: Brown GWB paper w/ paint (associated w/ tub walls)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A N/A
11035-TIN-
Main Floor, Master
Bathroom
Layer 1: 24”x24” Light gray ceramic floor tile
Layer 2: Off-white grout
Layer 3: Off-white mortar (on concrete)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Main Floor, Master
Bathroom
Layer 1: 12”x12” White/red ceramic floor tile Layer 2: White grout
Layer 3: Gray mortar (on gray fibrous underlayment)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Main Floor, Entry
Black plastic electrical panel components (in 1’x1.5’ electrical panel)
ND N/A
11035-TIN-
Main Floor, Entry
Black plastic electrical panel components (in 1’x3’ electrical panel)
ND N/A
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Main Floor, Livingroom
Silver heater flue caulking (on 1’ OD flue)
ND N/A
11035-TIN-
Main Floor, Livingroom
Black asphaltic vapor barrier
(between wood decking and roof)
ND N/A
11035-TIN-
Main Floor, Livingroom
Layer 1: Black foam window glazing gasket w/ paint Layer 2: Clear mastic (on 6’x8’ vinyl-framed windows)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Main Floor, Master Bathroom
Layer 1: 9”x9” White/red ceramic wall tile
Layer 2: White grout Layer 3: Gray mortar
Layer 4: Cement board w/ mesh backing
Layer 5: Black asphaltic vapor barrier (associated w/ shower walls)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A N/A
N/A
N/A
11035-TIN-
Main Floor, Master Bedroom
Layer 1: Red ceramic brick
Layer 2: Gray mortar w/ paint (associated w/ heater pad)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Basement, Room B1
Layer 1: Tan carpet w/ paint
Layer 2: White woven backing Layer 3: Off-white mastic (on wood on stairs)
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-TIN-
Basement, Room B2
Layer 1: Dark green & red carpet w/ paint
Layer 2: Black woven backing Layer 3: Off-white mastic (on concrete)
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-TIN-
Basement, Sauna
Layer 1: Silver foil Layer 2: Brown paper
Layer 3: Wood (behind wood panels on ceiling)
L1: ND
L2: ND
L3: ND
N/A N/A
N/A
11035-TIN-
Basement, Sauna
Layer 1: Silver foil
Layer 2: Brown paper w/ black mastic
Layer 3: Yellow fiberglass batt insulation (in walls behind wood panels)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-TIN-
Basement, Room B3
Layer 1: Off-white SVF Layer 2: Off-white mastic
Layer 3: Wood counters
L1: ND
L2: ND
L3: ND
N/A
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Basement, Sauna
Layer 1: Light gray foam weather stripping
Layer 2: Clear mastic Layer 3: Wood door frame
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-TIN-
Basement Room B2
Layer 1: Black foam weather stripping Layer 2: Clear mastic (on wood door frame)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Basement
Room B2
Light yellow expanding foam (at wall penetrations throughout)
ND N/A
11035-TIN-
Basement Room B2
Gray pipe dope (on 1” OD natural gas line fittings)
ND N/A
11035-TIN-
Basement, Room B1
Layer 1: Brown paper w/ black mastic Layer 2: Pink fiberglass batt insulation (in basement ceiling)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
51QA
Main Floor, Exterior
Porch, North Side
Black asphaltic vapor barrier
(beneath metal roofing on wood)
ND N/A
11035-TIN-
Main Floor, Exterior Porch, East
Side
Black asphaltic vapor barrier (beneath metal roofing on wood)
ND N/A
11035-TIN-
Main Floor, Exterior
Porch, East
Side
Black asphaltic vapor barrier
(behind wood shingle siding on wood)
ND N/A
11035-TIN-
Main Floor, Exterior
Porch, South Side
Black asphaltic vapor barrier (behind wood horizontal siding on wood)
ND N/A
11035-TIN-
Main Floor, Exterior Porch, North
Side
White/yellow window glazing patty (on 6”x3’ wood-framed stained-glass windows)
ND N/A
11035-TIN-
Main Floor
Exterior, North Side
Layer 1: Brown seam caulking w/ paint (associated w/ all exterior seams & window frames)
Layer 2: Wood
L1: ND
L2: ND
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Basement Exterior, West Side
Brown/gray pipe dope (at connections on 1” OD natural gas pipe)
ND N/A
11035-TIN-
Basement Exterior, South Side
Black asphaltic vapor barrier (between dirt and concrete foundation
ND N/A
11035-TIN-
Basement Exterior, South Side
Black asphaltic roofing w/ sand (used as basement entry traction pad)
ND N/A
11035-TIN-
Main Floor Exterior, North Side
Layer 1: Off-white cement panel
Layer 2: Gray cement board
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Log Shed Exterior
Black asphaltic vapor barrier (beneath wood shingle roof on wood)
ND N/A
11035-TIN-
Exterior Fireplace 1
Gray mortar (associated w/ stone outdoor fireplace)
ND N/A
11035-TIN-
Exterior Fireplace 1
Layer 1: Off-white fire-brick
Layer 2: Light gray mortar (associated w/ outdoor fireplace)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Exterior Fireplace 2
Layer 1: Gray/white stone Layer 2: Gray mortar
L1: ND
L2: ND
N/A N/A
11035-TIN-
Exterior Fireplace 2
Layer 1: Orange/tan fire-brick
Layer 2: Gray mortar w/ paint Layer 3: Trace white sandy material
L1: ND
L2: ND
L3: ND
N/A
N/A N/A
11035-TIN-
Exterior, Lake Side Shed
Layer 1: Black asphaltic vapor barrier (beneath wood shingles) Layer 2: Wood roof shingles
(on wood)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Exterior, Lake Side
Shed
Layer 1: Trace silver paint Layer 2: Black asphaltic vapor barrier Layer 3: Yellow fiberglass insulation
Layer 4: Brown paper w/ black mastic (behind wood siding)
L1: ND
L2: ND
L3: ND
L4: ND
N/A N/A
N/A
N/A
11035-TIN-
Exterior, Lake Side Shed
White rubber SVF (on wood, mechanically fastened)
ND N/A
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
69QA
Exterior, Pump House
Black asphaltic vapor barrier (under wood shingle siding and roof)
ND N/A
11035-TIN-
Garage/ Lean-to, Lean-to Roof, SE
Corner
Layer 1: Red granules on black asphaltic rolled down roofing
Layer 2: Black asphaltic vapor barrier (on wood)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Garage/ Lean-to, Lean-to Roof, NE
Corner
Layer 1: Red granules on black asphaltic rolled down roofing Layer 2: Black asphaltic vapor barrier (on wood)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Garage/ Lean-to, Garage
Roof, NE Corner
Layer 1: Black asphaltic vapor barrier Layer 2: Wood (beneath metal sheet roofing on wood)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Garage/
Lean-to, Garage
Roof, SE Corner
Layer 1: Black asphaltic vapor barrier Layer 2: Trace wood (beneath metal sheet roofing on wood)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Garage/
Lean-to, Interior
White bathtub edge caulking
(on 5’x3’ oval tub)
ND N/A
11035-TIN-
Garage/
Lean-to, Interior
White sink caulking (on double cast iron sink & single porcelain sink)
ND N/A
11035-TIN-
Garage/
Lean-to, Interior
Layer 1: Black foam furnace gasket Layer 2: Clear mastic (on
2’x2’x6’ furnace)
L1: ND
L2: ND
N/A
N/A
11035-TIN-
Garage/ Lean-to, Interior
Layer 1: Silver foil duct tape Layer 2: Clear mastic
Layer 3: Clear plastic (on 2’x2’x6’ furnace)
L1: ND
L2: ND
L3: ND
N/A N/A
N/A
11035-TIN-
Garage/ Lean-to, Interior
Layer 1: Off-white mastic
Layer 2: Trace white JC w/ paint and paper (associated w/ granite kitchen counters & backdrop)
L1: ND
L2: ND
EHSI Project 11035 November 6th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-TIN-
Garage/
Lean-to, Interior
Layer 1: White seam sealant Layer 2: Trace white JC w/ paint (used at kitchen cabinetry edges where in contact w/ walls)
L1: ND
L2: ND
N/A N/A
11035-TIN-
Garage/
Lean-to, Interior
Off-white mastic (between granite & wood associated w/ master bathroom granite counters and backdrop)
ND N/A
KEY: GWB = gypsum wall board, JC = joint compound, ND = non-detect, N/A = not applicable, OD = outer diameter, w/ = with, SVF = sheet vinyl flooring, Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey and un-sampled materials assumed to be ACM. The Table 2
Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
1’3”x2’6” Electrical panel with assumed ACM internal components
Garage Interior, NE corner
1 EA
KEY: ACM = asbestos containing material, w/ = with
ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect
ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.
2.4.2 Lead-Containing Paint and Building Materials
Fifty-five (55) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer.
Results marked with “< LOD” are less than the limit of detection. XRF paint sample results ranged from 0.34 milligrams of lead per square centimeter (mg Pb/cm2) to < LOD mg Pb/cm2.
Bolded results indicate materials coated with “lead-based paint” (e.g., >1.0
EHSI Project 11035 November 6th, 2017 mg/cm2) as defined by USEPA regulation 40CFR745 and Washington State
Commerce regulation WAC 365-230. The results are provided in Table 3 of this report.
EHSI also noted the presence of two (2) 6”x3’ stained-glass windows located in the front entryway that are assumed to contain lead cames and solder.
Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
Read
Component Substrate Color Building Room Lead Conc.
(mg/cm2)
1 NIST Check Wood Red Tinkham Property N/A 0.94
2 NIST Check Wood Red Tinkham Property N/A 0.96
3 NIST Check Wood Red Tinkham Property N/A 0.96
4 Door Wood Brown Tinkham Property Entry <LOD
5 Door Frame Wood Brown Tinkham Property Entry <LOD
6 Door Trim Wood White Tinkham Property Entry <LOD
7 Wall Drywall White Tinkham Property Entry <LOD
8 Ceiling Drywall White Tinkham Property Entry <LOD
9 Baseboard Wood White Tinkham Property Entry <LOD
10 Door Frame Wood White Tinkham Property Entry <LOD
11 Floor Ceramic Light Gray Tinkham Property Entry 0.1
12 Floor Ceramic Light Gray Tinkham Property Kitchen 0.08
13 Floor Ceramic Light Gray Tinkham Property Kitchen 0.08
14 Floor Ceramic Light Gray Tinkham Property Kitchen 0.04
15 Door Frame Wood White Tinkham Property Livingroom <LOD
16 Structural Beam Wood Dark Brown Tinkham Property Livingroom 0.02
17 Ceiling Wood Brown Tinkham Property Livingroom <LOD
18 Stairs Wood White Tinkham Property Loft <LOD
19 Guard Rail Wood Brown Tinkham Property Loft <LOD
20 Door Wood White Tinkham Property Master
Bedroom
<LOD
21 Floor Brick Red Tinkham Property Master
Bedroom
<LOD
22 Floor Ceramic Off White Tinkham Property Master
Bathroom 0.02
23 Shower Ceramic Off White Tinkham Property Master
Bathroom
<LOD
24 Shower Ceramic Gray Tinkham Property Master
Bathroom
<LOD
EHSI Project 11035 November 6th, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
Read
Component Substrate Color Building Room Lead Conc.
(mg/cm2)
25 Wall Drywall White Tinkham Property Master
Bathroom
<LOD
26 Wall Drywall White Tinkham Property Interior <LOD
27 Wall Wood White Tinkham Property Interior <LOD
28 Door Metal White Tinkham Property Interior <LOD
29 Stairs Wood White Tinkham Property Interior <LOD
30 Baseboard Wood Black Tinkham Property Interior <LOD
31 Door Wood Brown Tinkham Property Exterior <LOD
32 Door Frame Wood Brown Tinkham Property Exterior <LOD
33 Door Trim Wood Brown Tinkham Property Exterior <LOD
34 Wall Trim Wood White Tinkham Property Exterior <LOD
35 Fascia Wood White Tinkham Property Exterior <LOD
36 Gutter Metal Green Tinkham Property Exterior <LOD
37 Roof Flashing Metal Green Tinkham Property Exterior <LOD
38 Roof Metal Green Tinkham Property Exterior <LOD
39 Downspout Metal Green Tinkham Property Exterior 0.3
40 Door Metal White Tinkham Property Exterior <LOD
41 Door Frame Wood White Tinkham Property Exterior <LOD
42 Door Trim Wood White Tinkham Property Exterior <LOD
43 Window Trim Wood White Tinkham Property Exterior <LOD
44 Wall Trim Wood Brown Tinkham Property Pump
House Ext.
<LOD
45 Wall Metal Light Gray Tinkham Property Garage
Interior
<LOD
46 Door Metal White Tinkham Property Garage
Interior
<LOD
47 Door Metal White Tinkham Property Garage
Interior
<LOD
48 Door Frame Wood White Tinkham Property Garage
Interior
<LOD
49 Door Metal White Tinkham Property Garage
Exterior
<LOD
50 Door Frame Wood White Tinkham Property Garage
Exterior
<LOD
51 Door Trim Wood White Tinkham Property Garage
Exterior
<LOD
52 Structural Beam Wood Dark Brown Tinkham Property Garage
Exterior
<LOD
53 Fascia Wood White Tinkham Property Garage
Exterior
<LOD
EHSI Project 11035 November 6th, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
Read
Component Substrate Color Building Room Lead Conc.
(mg/cm2)
54 Wall Metal Light Gray Tinkham Property Garage
Exterior
<LOD
55 Roof Metal Dark Brown Tinkham Property Garage
Exterior 0.03
56 Wall Trim Wood White Tinkham Property Garage
Exterior
<LOD
57 Door Metal White Tinkham Property Garage
Exterior
<LOD
58 Downspout Metal Green Tinkham Property Garage
Exterior 0.34
59 NIST Check Wood Red Tinkham Property N/A 0.96
60 NIST Check Wood Red Tinkham Property N/A 0.92
61 NIST Check Wood Red Tinkham Property N/A 0.93
In addition to the XRF samples, EHSI collected two (2) bulk QA samples for laboratory analysis. The bulk sample results ranged from 0.0052 percent lead by weight to 0.0078 percent lead by weight. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations.
Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.
Copies of the analytical laboratory report and field data forms for lead paint are included in
Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
SAMPLE
NUMBER
LOCATION
COMPONENT/
SUBSTRATE
COLOR
RESULTS
% Pb by
WT
11035-TIN-
Pb01
Main Floor, Master Bedroom Heater Pad/Brick
& Mortar Red & Gray 0.0052
11035-TIN-
Pb02 Basement, Exterior East Side
Fireplace/Stone &
Mortar Gray 0.0078
Key: Pb = lead, WT = weight
EHSI Project 11035 November 6th, 2017
DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).
At the request of NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos Survey. The results of that lead-TCLP analysis indicate leachable lead present in the anticipated demolition waste stream at a concentration of <0.5 mg/L. A detailed list of the materials included in the TCLP sample are provided in Appendix F.
It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.
2.4.4 Polychlorinated Biphenyls
Ballasts EHSI inspected a representative number of each type of fluorescent fixture for PCB-containing ballasts. A select number of fixtures inspected were found to contain magnetic ballasts and must be assumed to contain PCB containing dialectic fluid; therefore, they must be disposed/recycled as Ecology Dangerous Waste. A Summary of ballasts and Hg-containing light tubes is provided in Table 5.
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
All fluorescent light tubes and CFL bulbs quantified in Table 5 contain Hg. Hg wastes are regulated as “universal wastes” under Ecology’s regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste. No Hg-containing switches or thermostats were identified in the structures.
TABLE 5
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
LIGHT TYPE FIXTURES
TUBES/
BULBS
MAGNETIC
BALLASTS
4”x4’ Mounted light fixture w/ 2 bulbs and 1 magnetic ballast (in garage) 1 2 1
EHSI Project 11035 November 6th, 2017
TABLE 5
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
NATIONAL PARK SERVICE
LAKE CRESCENT – TINKHAM PROPERTY
LIGHT TYPE FIXTURES
TUBES/
BULBS
MAGNETIC
BALLASTS
6”x4’ Mounted light fixture w/ 1 bulb and 1 magnetic ballast (on underside of loose cabinet in garage)
1 1 1
Light fixture w/ 1 CFL bulb 1 1 0
Total Tinkham Property 3 4 2 Key: CFL = compact fluorescent light
3.0 LIMITATIONS
This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished; however, energized electrical panels, were not sampled but were assumed to have ACM internal components. All suspect materials present were accessible for sampling.
This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be
ACM by this survey report when encountered must be treated as ACM until sampled by a Certified AHERA Building Inspector and analyzed by a certified laboratory.
4.0 STANDARD OF CARE
The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.
5.0 CERTIFIED AHERA BUILDING INSPECTORS
The Certified AHERA Building Inspectors listed below surveyed on September 26th, 2017, in accordance with federal, state, and local requirements.
Rory Peterson Mike Ruark Certified AHERA Building Inspector Certified AHERA Building Inspector
Certificate Number: 1628987 Certificate Number: 163007
Expiration Date: August 23, 2018 Expiration Date: September 6, 2018
Appendix A
APPENDIX A
Asbestos Analytical Laboratory Report and Field Data Forms
Nick Ly, Technical Director
Client Project: 11035-01
Location: Tinkham Property
Dear Mr. Peterson, Enclosed please find test results for the 4 sample(s) submitted to our laboratory for analysis on
10/2/2017.
Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116
Method for the Determination of Asbestos in Bulk Building Materials.
For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.
For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.
The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results
October 4, 2017
Nick L T hnical D
Rory Peterson
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1717430.00
< Client:
Address:
Attention: Mr. Rory Peterson
Tinkham Property
Client Project #: 11035-01
Samples Received: 4
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 4
Project Location:
Batch #: 1717430.00
Date Received: 10/2/2017
17095333Lab ID: Client Sample #:
Location: Tinkham Property
11035-TIN-20QA
Layer 1 of 2 Description: White brittle material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Calcareous binder 3%Cellulose None Detected ND
Layer 2 of 2 Description: Brown wood debris
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Wood flakes 34%Wood fibers None Detected ND
17095334Lab ID: Client Sample #:
Location: Tinkham Property
11035-TIN-23QA
Layer 1 of 3 Description: Gray cementitious material with fibrous material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Cement/Binder 2%Cellulose None Detected ND
10%Glass fibers
Layer 2 of 3 Description: Gray compressed fibrous material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler 70%Cellulose None Detected ND
Layer 3 of 3 Description: Black asphaltic fibrous material with debris
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Binder/Filler, Wood flakes 66%Cellulose None Detected ND
4%Wood fibers
17095335Lab ID: Client Sample #:
Location: Tinkham Property
11035-TIN-51QA
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Lori TsengAnalyzed by:
Nick LyReviewed by:
10/04/2017 Date:
10/04/2017Date:
Sampled by:
< Client:
Address:
Attention: Mr. Rory Peterson
Tinkham Property
Client Project #: 11035-01
Samples Received: 4
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 4
Project Location:
Batch #: 1717430.00
Date Received: 10/2/2017
Layer 1 of 1 Description: Black asphaltic fibrous felt
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Binder/Filler 74%Cellulose None Detected ND
17095336Lab ID: Client Sample #:
Location: Tinkham Property
11035-TIN-69QA
Layer 1 of 1 Description: Black asphaltic fibrous felt
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Binder/Filler 78%Cellulose None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Lori TsengAnalyzed by:
Nick LyReviewed by:
10/04/2017 Date:
10/04/2017Date:
Sampled by:
EHS International 1717430.00
Company NVL Batch Number
Total Number of Samples
Tinkham Property
5 DaysTAT
10/9/2017Due Date 10:40 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-01Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals
ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-TIN-20QA1 A17095333
11035-TIN-23QA2 A17095334
11035-TIN-51QA3 A17095335
11035-TIN-69QA4 A17095336
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Lori TsengAnalyzed by
Results Called by
NVL
NVL
10/2/17
10/4/17
Print Name
Entered By: Umer Khan
Date: 10/2/2017
Time: 11:05 AM
Special
Instructions:
Appendix B
APPENDIX B
Lead Laboratory Reports and Field Data Forms
RE: Metals Analysis; NVL Batch # 1717428.00
Dear Mr. Peterson, October 5, 2017
EHS International
Rory Peterson
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.
This report is considered highly confidential and will not be released without your approval.
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.
Sincerely, Shalini Patel, Laboratory Analyst
Analysis Report Total Lead (Pb)
Tinkham Property
EHS InternationalClient:
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Mr. Rory PetersonAttention:
Address:
Project Location: Samples Received: 2
Samples Analyzed: 2
Client Project #: 11035-01
Batch #: 1717428.00
Date Received: 10/2/2017
Lab ID Client Sample #
Sample
Weight (g)
Results in mg/Kg
Resul…
This is the start of the file's text. The full file is on GovTribe.