Attchmt 10_Tinkham Property Report.pdf

PDF 15 MB Posted

Attached to
Hazardous Materials Abatement, OLYM Federal contract opportunity
Solicitation number
140P8318Q0051
Issued by
Department of the Interior National Park Service

About this file

Not Listed

View the file

Other files for this federal contract opportunity

Other files attached to Hazardous Materials Abatement, OLYM, newest first.
File Type Posted
Attchmt 23_Option 8-Kleiva Property Report.pdf PDF
Attchmt 19_Option 4-Kennedy Property Report.pdf PDF
Attchmt 17_Option 2-Hoiness Property Report.pdf PDF
Attchmt 21_Option 6-Walker Property Report.pdf PDF
Attchmt 16_Option 1-Clayton Property Report.pdf PDF
Attchmt 20_Option 5-Perrigo Property Report.pdf PDF
Attchmt 18_Option 3-Hopkins Property Report.pdf PDF
Attchmt 22_Option 7-Haubrich Property Report.pdf PDF
Attchmt 8_ Dinkleman Property Reportl.pdf PDF
Attchmt 15_Quinault Resort Property Report.pdf PDF
Attchmt 9_Erspamer Property Report.pdf PDF
Attchmt 12_Bemis Property Report.pdf PDF
Attchmt 11_Wolfe Property Report.pdf PDF
Zip_File_1_of_2_Attachments_7_to_15_Property_Reports.zip ZIP file
Attchmt 14_Gilroy Property Report.pdf PDF
Attchmt 7_Bird and Bird Guest Property Report.pdf PDF
Zip_File_1_of_2_Attachments_7_to_15_Property_Reports.zip ZIP file
Attchmt 13_Fulleton Property Report.pdf PDF
Attchmt_4_Summary_Table_of_HazMat_Sites.pdf PDF
Attchmt_5_Site_Maps.pdf PDF
Attchmt_1_Combined_Synopsis-Solicitation_Full_Text.pdf PDF
Attchmt_3_Scope_of_Work.pdf PDF
Attchmt_2_DOL_Wage_15-5545.pdf PDF
Attchmt_6_Site_Photos.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1011 SW Klickitat Way, Suite 104, Seattle, Washington 98134

Phone 206-381-1128

Toll Free 800-666-2959

Fax 206-254-4279

Environmental Consulting

Hazardous Materials Management

Industrial Hygiene Services

Construction Management

Indoor Air Quality

LIMITED LEAD AND ASBESTOS SURVEY REPORT

NATIONAL PARK SERVICE - OLYMPIC NATIONAL PARK

LAKE CRESCENT - TINKHAM PROPERTY

1324 Camp David Jr. Road

Port Angeles, Washington 98363

November 6th, 2017

Prepared For:

Jeff Doryland

Deputy Chief of Facility Management

Olympic National Park

600 E. Park Avenue, Port Angeles, WA 98273 ii

Limited Lead and Asbestos Survey Report

National Park Service – Olympic National Park

Lake Crescent - Tinkham Property

1324 Camp David Jr. Road

Port Angeles, Washington

EHSI Project No.: # 11035

The material and data in this report were prepared under the supervision and direction of the undersigned.

Rory Peterson

Lead AHERA Building Inspector

Derica Escamilla

Principal of Hazardous Materials

Services iii

TABLE OF CONTENTS

Acronym List .................................................................................... iv

1.0 EXECUTIVE SUMMARY

1.1 BACKGROUND

1.2 EXTENT OF CURRENT SURVEY

1.3 ACM MATERIALS FOUND

1.4 OPINIONS AND RECOMMENDATIONS

1.5 LIMITATIONS/DISCLAIMER

2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT

2.1 BACKGROUND

2.2 BUILDING DESCRIPTION

2.3 SAMPLING METHODOLOGY

2.3.1 Asbestos-Containing Materials

2.3.2 Lead-Containing Paint/Lead-Containing Materials

2.4 SAMPLING RESULTS

2.4.1 Asbestos-Containing Materials

2.4.2 Lead-Containing Paint and Building Materials

2.4.3 Toxicity Characteristic Leaching Procedure Sampling

2.4.4 Polychlorinated Biphenyls

2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs

3.0 LIMITATIONS

4.0 STANDARD OF CARE

5.0 CERTIFIED AHERA BUILDING INSPECTORS

APPENDICES

A........................ Asbestos Laboratory Reports and Field Data Forms

B........................ Lead Laboratory Reports and Field Data Forms

C........................ Certified AHERA Building Inspector Certificates

D ....................... Laboratory Certifications for Asbestos and Lead Analysis

E ........................ Sample Location Drawings for Asbestos, Lead, and TCLP

F ........................ Lead TCLP Laboratory Reports and Field Data Forms

G ....................... Abatement Cost Estimate iv

ACRONYM LIST

ACM.......................Asbestos-Containing Material

AHERA ................... Asbestos Hazard Emergency Response Act AIHA ...................... American Industrial Hygiene Association

CFL ........................ Compact Fluorescent Light CFR ....................... Code of Federal Regulations

DOSH.....................Washington State Department of Labor and Industries, Division of

Occupational Safety and Health EA ......................... Each

Ecology .................. Washington State Department of Ecology EHSI ...................... EHS-International, Inc.

ELLAP .....................Environmental Lead Laboratory Accreditation Program GWB ...................... Gypsum Wall Board

Hg ......................... Mercury JC..........................Joint Compound

LCM ....................... Lead-Containing Material

LCP........................Lead-Containing Paint L&I ........................ Washington State Department of Labor and Industries mg/cm2 .................. Milligrams Per Square Centimeters mg/L......................Milligrams Per Liter

N/A ........................Not Applicable ND.........................None Detected

NVL ....................... NVL Laboratories, Inc.

NVLAP .................... National Voluntary Laboratory Accreditation Program

OSHA ..................... US Occupational Safety and Health Administration

ORCAA ................... Olympic Clean Air Agency Pb ......................... Lead

PCBs ...................... Polychlorinated Biphenyls PLM ....................... Polarized Light Microscopy ppm.......................Parts per Million QA ......................... Quality Assurance

RCW ...................... Revised Code of Washington SAT ....................... Seattle Asbestos Test, LLC

SVF........................Sheet Vinyl Flooring

TCLP ...................... Toxicity Characteristic Leaching Procedure WAC ...................... Washington Administrative Code

WT ........................ Weight w/ ......................... With

XRF ....................... x-ray fluorescence

NPS – Lake Crescent - Tinkham Property

EHSI Project 11035 November 6th, 2017

1.0 EXECUTIVE SUMMARY

1.1 BACKGROUND

The National Park Service (NPS) plans to demolish the existing structures on the Tinkham

Property located on Lake Crescent at 1324 Camp David Jr. Road, Port Angeles, Washington.

The NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Tinkham Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure (TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl (PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.

1.2 EXTENT OF CURRENT SURVEY

EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:

interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.

1.3 ACM MATERIALS FOUND

SUMMARY OF ASBESTOS-CONTAINING MATERIALS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

ASBESTOS MATERIAL DESCRIPTION LOCATION

1’3”x2’6” Electrical panel w/ assumed ACM internal components Garage Interior, NE corner KEY: ACM = asbestos containing material, w/ = with,

1.4 OPINIONS AND RECOMMENDATIONS

The project includes demolition of the existing structures at the Tinkham Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.

Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.

Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the

EHSI Project 11035 November 6th, 2017 type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).

Fluorescent light fixtures inspected have magnetic ballasts which are assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. Magnetic ballasts must be removed from fixtures and disposed of as Washington Department of Ecology (Ecology)

Dangerous Waste. All fluorescent tubes and bulbs contain mercury; any fluorescent tubes/bulbs to be disturbed during the project must be recycled as (Ecology) Universal Waste.

1.5 LIMITATIONS/DISCLAIMER

This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. Energized electrical panels were not sampled but were assumed to have ACM internal components based on the inspector’s experience with similar systems on other projects. This report and accompanying appendices include the supporting information for this executive summary.

EHSI Project 11035 November 6th, 2017

2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT

2.1 BACKGROUND

The NPS plans to demolish the existing structures at the Tinkham Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:

identification of all suspect materials; a determination of whether suspect materials were:

ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.

On September 26th, 2017, EHSI conducted a Limited Lead and Asbestos Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of

Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region

Clean Air Agency (ORCAA).

2.2 BUILDING DESCRIPTION

The Tinkham Property is located on Lake Crescent at 1324 Camp David Jr. Road, Port Angeles, Washington. Structures on the property include a one-story single occupancy residential house w/ loft and partially finished basement, a detached two car garage with covered carport, a small single room lake-side shed, a deteriorating log shack, a small pump house, and two exterior free-standing stone fireplaces.

The house is a wood-framed structure with a concrete foundation and metal roof. Interior floor finishes include: carpet and some ceramic tile, unfinished areas of basement are bare concrete. Interior wall finishes include: GWB and wood paneling in the basement sauna.

Interior ceiling finishes include: GWB and tongue & groove wood planks. Windows are vinyl framed and some but not all are operable. Hot water was provided by an electric domestic hot water tank which has already been removed. Heating was provided by a natural gas furnace which has been removed and moved into the garage. Interior lighting fixtures were removed from the house.

The detached two car garage is a single-story high-bay wood-framed structure with poured concrete slab foundation and metal roofing over the garage and corrugated fiber reinforced roofing panels over the carport. The garage has sheet metal exterior siding and unfinished interior walls and ceiling. The interior had electrical wiring for lighting and garage door openers. There was no heating or plumbing for this structure.

The small lake-side shed has wood framing and wood exterior siding, with a wood shingle roof. Interior floor has SVF on a wood subfloor resting directly on top of bare dirt. There was no electrical, heating, or plumbing for this structure.

EHSI Project 11035 November 6th, 2017

The deteriorating log shack had a partially collapsed roof with wood shingles, log walls and no foundation. Interior floor was dirt. No electric lighting, plumbing or heating is present in this structure.

The small “pump house” is a wood framed structure with wood shingle siding and roof on CMU blocks. No electrical wiring, plumbing or heating were present for this structure. Interior floor, ceiling and walls are unfinished.

2.3 SAMPLING METHODOLOGY

2.3.1 Asbestos-Containing Materials

The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of

Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix

C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October

1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.

EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and

Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary

Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.

Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.

Copies of both laboratories’ NVLAP certifications are included in Appendix D.

2.3.2 Lead-Containing Paint/Lead-Containing Materials

EHSI used an Olympus Delta-Pro x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial

Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program (ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.

EHSI Project 11035 November 6th, 2017

2.4 SAMPLING RESULTS

2.4.1 Asbestos-Containing Materials

Eighty (80) bulk samples of suspect ACM were collected as part of the survey. Four (4) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. Suspect materials not sampled were assumed to be ACM.

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Main Floor, Kitchen

Layer 1: Bumpy white texturing w/ paint and paper Layer 2: GWB wall w/ paper

(corner)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Kitchen /

Dining

Room

Layer 1: Bumpy white texturing w/ paint

Layer 2: GWB wall w/ paint and paper (mid-wall)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Livingroom

Layer 1: Bumpy white texturing w/ paint

Layer 2: GWB wall w/ paint and paper (mid-wall)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Loft

Layer 1: Bumpy white texturing w/ paint Layer 2: GWB wall w/ paint and paper (mid-wall)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Hall

Layer 1: Bumpy white texturing w/ paint

Layer 2: White JC w/ paint Layer 3: GWB wall w/ paper

(corner)

L1: ND

L2: ND

L3: ND

N/A

N/A N/A

11035-TIN-

Main Floor, Master

Bedroom

Layer 1: Bumpy white texturing w/ paint

Layer 2: GWB wall w/ paint and paper (mid-wall)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Walk-in Closet

Layer 1: Trace bumpy white texturing w/ paint Layer 2: White JC w/ paint and paper Layer 3: GWB wall w/ paper

(corner)

L1: ND

L2: ND

L3: ND

N/A

N/A

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Main Floor, Master

Bathroom

GWB wall w/ white paint and paper (mid-wall)

ND N/A

11035-TIN-

Main Floor, Master

Bathroom

Layer 1: White JC w/ white paint and paper

Layer 2: GWB wall w/ paper (corner)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Master Bathroom

GWB wall w/ white paint and paper (mid-wall)

ND N/A

11035-TIN-

Main Floor, Master

Bathroom

Layer 1: Silvery white wall paper Layer 2: Clear mastic

Layer 3: Brown GWB paper w/ paint

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Main Floor, Master

Bathroom

Layer 1: Troweled on white texturing w/ paint and paper Layer 2: GWB ceiling w/ paper

(edge)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Master Bathroom

Layer 1: Troweled on white texturing w/ paint

Layer 2: GWB ceiling w/ paper

(mid-ceiling)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Master

Bedroom

Layer 1: Troweled on white texturing w/ paint

Layer 2: GWB ceiling w/ paper (mid-ceiling)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Kitchen/Dini ng Room

Layer 1: Troweled on white texturing w/ paint Layer 2: White JC w/ paint

Layer 3: GWB ceiling w/ paper (edge)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Main Floor, Kitchen/Dini ng Room

Layer 1: Troweled on white texturing w/ paint Layer 2: GWB ceiling w/ paint and paper (mid-ceiling)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Basement, Room B1

Layer 1: Thick troweled on white texturing w/ paint

Layer 2: GWB wall w/ paper (wall-mid)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Basement, Room B1

Layer 1: Thick troweled on white texturing w/ paint Layer 2: Brown OSB (wall-seam)

L1: ND

L2: ND

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Basement, Room B1

Layer 1: Thick troweled on white texturing w/ paint

Layer 2: Black tape w/ woven backing

Layer 3: Gray mastic (on particle board) (wall-seam)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

20QA

Main Floor, Livingroom

Layer 1: Thick white/gray leveling compound Layer 2: Wood particle board

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Livingroom

Layer 1: Wood particle board

Layer 2: Silver foil Layer 3: Brown paper w/ mastic

Layer 4: Wood subfloor

L1: ND

L2: ND

L3: ND

L4: ND

N/A

N/A N/A

N/A

11035-TIN-

Main Floor, Livingroom

Layer 1: Gray/green carpet

Layer 2: White mesh backing

Layer 3: Beige mastic Layer 4: Blue/yellow foam carpet pad (mechanically fastened to wood)

L1: ND

L2: ND

L3: ND

L4: ND

N/A

N/A

N/A N/A

11035-TIN-

23QA

Main Floor, Kitchen/Dini ng Room

Layer 1: Gray seam cement

Layer 2: Light gray/gray fibrous underlayment

Layer 3: Black asphaltic vapor barrier (on wood subfloor)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Main Floor, Kitchen/Dini ng Room

Layer 1: 12”x12” Off-white/brown ceramic floor tile Layer 2: White grout

Layer 3: Gray mortar (on Sample 11035-TIN-23)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Main Floor, Kitchen/Dini ng Room

Black asphaltic vapor barrier

(under carpet & particle board on wood subfloor throughout)

ND N/A

11035-TIN-

Main Floor, Livingroom

Layer 1: Trace white texturing w/ paint Layer 2: White door frame caulking w/ paint

Layer 3: Brown paper (on all interior & exterior doors)

L1: ND

L2: ND

L3: ND

N/A

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Main Floor, Master

Bedroom

Layer 1: Trace white texturing w/ paint

Layer 2: White door frame caulking w/ paint

Layer 3: Brown paper (on all interior & exterior doors)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Main Floor, Bathroom

Layer 1: 12”x12” Light gray ceramic tile Layer 2: Gray grout

Layer 3: Pink mortar

Layer 4: Light gray leveling compound (on concrete)

L1: ND

L2: ND

L3: ND

L4: ND

N/A

N/A

N/A

N/A

11035-TIN-

Main Floor, Bathroom

Off-white seam caulking (on tile in Sample 11035-TIN-28 to seal base of toilet)

ND N/A

11035-TIN-

Main Floor, Master Bathroom

Layer 1: 9”x9” White/red ceramic floor tile Layer 2: White grout

Layer 3: Gray mortar Layer 4: Gray/light gray fibrous underlayment (associated w/ tub floor)

L1: ND

L2: ND

L3: ND

L4: ND

N/A

N/A

N/A N/A

11035-TIN-

Main Floor, Master Bathroom

Layer 1: 9”x9” White/red ceramic wall tile Layer 2: White grout

Layer 3: White mastic Layer 4: Brown GWB paper w/ paint (associated w/ tub walls)

L1: ND

L2: ND

L3: ND

L4: ND

N/A

N/A

N/A N/A

11035-TIN-

Main Floor, Master

Bathroom

Layer 1: 24”x24” Light gray ceramic floor tile

Layer 2: Off-white grout

Layer 3: Off-white mortar (on concrete)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Main Floor, Master

Bathroom

Layer 1: 12”x12” White/red ceramic floor tile Layer 2: White grout

Layer 3: Gray mortar (on gray fibrous underlayment)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Main Floor, Entry

Black plastic electrical panel components (in 1’x1.5’ electrical panel)

ND N/A

11035-TIN-

Main Floor, Entry

Black plastic electrical panel components (in 1’x3’ electrical panel)

ND N/A

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Main Floor, Livingroom

Silver heater flue caulking (on 1’ OD flue)

ND N/A

11035-TIN-

Main Floor, Livingroom

Black asphaltic vapor barrier

(between wood decking and roof)

ND N/A

11035-TIN-

Main Floor, Livingroom

Layer 1: Black foam window glazing gasket w/ paint Layer 2: Clear mastic (on 6’x8’ vinyl-framed windows)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Main Floor, Master Bathroom

Layer 1: 9”x9” White/red ceramic wall tile

Layer 2: White grout Layer 3: Gray mortar

Layer 4: Cement board w/ mesh backing

Layer 5: Black asphaltic vapor barrier (associated w/ shower walls)

L1: ND

L2: ND

L3: ND

L4: ND

L5: ND

N/A

N/A N/A

N/A

N/A

11035-TIN-

Main Floor, Master Bedroom

Layer 1: Red ceramic brick

Layer 2: Gray mortar w/ paint (associated w/ heater pad)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Basement, Room B1

Layer 1: Tan carpet w/ paint

Layer 2: White woven backing Layer 3: Off-white mastic (on wood on stairs)

L1: ND

L2: ND

L3: ND

N/A

N/A N/A

11035-TIN-

Basement, Room B2

Layer 1: Dark green & red carpet w/ paint

Layer 2: Black woven backing Layer 3: Off-white mastic (on concrete)

L1: ND

L2: ND

L3: ND

N/A

N/A N/A

11035-TIN-

Basement, Sauna

Layer 1: Silver foil Layer 2: Brown paper

Layer 3: Wood (behind wood panels on ceiling)

L1: ND

L2: ND

L3: ND

N/A N/A

N/A

11035-TIN-

Basement, Sauna

Layer 1: Silver foil

Layer 2: Brown paper w/ black mastic

Layer 3: Yellow fiberglass batt insulation (in walls behind wood panels)

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-TIN-

Basement, Room B3

Layer 1: Off-white SVF Layer 2: Off-white mastic

Layer 3: Wood counters

L1: ND

L2: ND

L3: ND

N/A

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Basement, Sauna

Layer 1: Light gray foam weather stripping

Layer 2: Clear mastic Layer 3: Wood door frame

L1: ND

L2: ND

L3: ND

N/A

N/A N/A

11035-TIN-

Basement Room B2

Layer 1: Black foam weather stripping Layer 2: Clear mastic (on wood door frame)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Basement

Room B2

Light yellow expanding foam (at wall penetrations throughout)

ND N/A

11035-TIN-

Basement Room B2

Gray pipe dope (on 1” OD natural gas line fittings)

ND N/A

11035-TIN-

Basement, Room B1

Layer 1: Brown paper w/ black mastic Layer 2: Pink fiberglass batt insulation (in basement ceiling)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

51QA

Main Floor, Exterior

Porch, North Side

Black asphaltic vapor barrier

(beneath metal roofing on wood)

ND N/A

11035-TIN-

Main Floor, Exterior Porch, East

Side

Black asphaltic vapor barrier (beneath metal roofing on wood)

ND N/A

11035-TIN-

Main Floor, Exterior

Porch, East

Side

Black asphaltic vapor barrier

(behind wood shingle siding on wood)

ND N/A

11035-TIN-

Main Floor, Exterior

Porch, South Side

Black asphaltic vapor barrier (behind wood horizontal siding on wood)

ND N/A

11035-TIN-

Main Floor, Exterior Porch, North

Side

White/yellow window glazing patty (on 6”x3’ wood-framed stained-glass windows)

ND N/A

11035-TIN-

Main Floor

Exterior, North Side

Layer 1: Brown seam caulking w/ paint (associated w/ all exterior seams & window frames)

Layer 2: Wood

L1: ND

L2: ND

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Basement Exterior, West Side

Brown/gray pipe dope (at connections on 1” OD natural gas pipe)

ND N/A

11035-TIN-

Basement Exterior, South Side

Black asphaltic vapor barrier (between dirt and concrete foundation

ND N/A

11035-TIN-

Basement Exterior, South Side

Black asphaltic roofing w/ sand (used as basement entry traction pad)

ND N/A

11035-TIN-

Main Floor Exterior, North Side

Layer 1: Off-white cement panel

Layer 2: Gray cement board

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Log Shed Exterior

Black asphaltic vapor barrier (beneath wood shingle roof on wood)

ND N/A

11035-TIN-

Exterior Fireplace 1

Gray mortar (associated w/ stone outdoor fireplace)

ND N/A

11035-TIN-

Exterior Fireplace 1

Layer 1: Off-white fire-brick

Layer 2: Light gray mortar (associated w/ outdoor fireplace)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Exterior Fireplace 2

Layer 1: Gray/white stone Layer 2: Gray mortar

L1: ND

L2: ND

N/A N/A

11035-TIN-

Exterior Fireplace 2

Layer 1: Orange/tan fire-brick

Layer 2: Gray mortar w/ paint Layer 3: Trace white sandy material

L1: ND

L2: ND

L3: ND

N/A

N/A N/A

11035-TIN-

Exterior, Lake Side Shed

Layer 1: Black asphaltic vapor barrier (beneath wood shingles) Layer 2: Wood roof shingles

(on wood)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Exterior, Lake Side

Shed

Layer 1: Trace silver paint Layer 2: Black asphaltic vapor barrier Layer 3: Yellow fiberglass insulation

Layer 4: Brown paper w/ black mastic (behind wood siding)

L1: ND

L2: ND

L3: ND

L4: ND

N/A N/A

N/A

N/A

11035-TIN-

Exterior, Lake Side Shed

White rubber SVF (on wood, mechanically fastened)

ND N/A

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

69QA

Exterior, Pump House

Black asphaltic vapor barrier (under wood shingle siding and roof)

ND N/A

11035-TIN-

Garage/ Lean-to, Lean-to Roof, SE

Corner

Layer 1: Red granules on black asphaltic rolled down roofing

Layer 2: Black asphaltic vapor barrier (on wood)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Garage/ Lean-to, Lean-to Roof, NE

Corner

Layer 1: Red granules on black asphaltic rolled down roofing Layer 2: Black asphaltic vapor barrier (on wood)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Garage/ Lean-to, Garage

Roof, NE Corner

Layer 1: Black asphaltic vapor barrier Layer 2: Wood (beneath metal sheet roofing on wood)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Garage/

Lean-to, Garage

Roof, SE Corner

Layer 1: Black asphaltic vapor barrier Layer 2: Trace wood (beneath metal sheet roofing on wood)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Garage/

Lean-to, Interior

White bathtub edge caulking

(on 5’x3’ oval tub)

ND N/A

11035-TIN-

Garage/

Lean-to, Interior

White sink caulking (on double cast iron sink & single porcelain sink)

ND N/A

11035-TIN-

Garage/

Lean-to, Interior

Layer 1: Black foam furnace gasket Layer 2: Clear mastic (on

2’x2’x6’ furnace)

L1: ND

L2: ND

N/A

N/A

11035-TIN-

Garage/ Lean-to, Interior

Layer 1: Silver foil duct tape Layer 2: Clear mastic

Layer 3: Clear plastic (on 2’x2’x6’ furnace)

L1: ND

L2: ND

L3: ND

N/A N/A

N/A

11035-TIN-

Garage/ Lean-to, Interior

Layer 1: Off-white mastic

Layer 2: Trace white JC w/ paint and paper (associated w/ granite kitchen counters & backdrop)

L1: ND

L2: ND

EHSI Project 11035 November 6th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-TIN-

Garage/

Lean-to, Interior

Layer 1: White seam sealant Layer 2: Trace white JC w/ paint (used at kitchen cabinetry edges where in contact w/ walls)

L1: ND

L2: ND

N/A N/A

11035-TIN-

Garage/

Lean-to, Interior

Off-white mastic (between granite & wood associated w/ master bathroom granite counters and backdrop)

ND N/A

KEY: GWB = gypsum wall board, JC = joint compound, ND = non-detect, N/A = not applicable, OD = outer diameter, w/ = with, SVF = sheet vinyl flooring, Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey and un-sampled materials assumed to be ACM. The Table 2

Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.

TABLE 2

SUMMARY OF ASBESTOS-CONTAINING MATERIALS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY

1’3”x2’6” Electrical panel with assumed ACM internal components

Garage Interior, NE corner

1 EA

KEY: ACM = asbestos containing material, w/ = with

ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect

ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.

2.4.2 Lead-Containing Paint and Building Materials

Fifty-five (55) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer.

Results marked with “< LOD” are less than the limit of detection. XRF paint sample results ranged from 0.34 milligrams of lead per square centimeter (mg Pb/cm2) to < LOD mg Pb/cm2.

Bolded results indicate materials coated with “lead-based paint” (e.g., >1.0

EHSI Project 11035 November 6th, 2017 mg/cm2) as defined by USEPA regulation 40CFR745 and Washington State

Commerce regulation WAC 365-230. The results are provided in Table 3 of this report.

EHSI also noted the presence of two (2) 6”x3’ stained-glass windows located in the front entryway that are assumed to contain lead cames and solder.

Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.

TABLE 3

XRF SAMPLING

SUMMARY OF PAINTED COMPONENTS AND MATERIALS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

Read

Component Substrate Color Building Room Lead Conc.

(mg/cm2)

1 NIST Check Wood Red Tinkham Property N/A 0.94

2 NIST Check Wood Red Tinkham Property N/A 0.96

3 NIST Check Wood Red Tinkham Property N/A 0.96

4 Door Wood Brown Tinkham Property Entry <LOD

5 Door Frame Wood Brown Tinkham Property Entry <LOD

6 Door Trim Wood White Tinkham Property Entry <LOD

7 Wall Drywall White Tinkham Property Entry <LOD

8 Ceiling Drywall White Tinkham Property Entry <LOD

9 Baseboard Wood White Tinkham Property Entry <LOD

10 Door Frame Wood White Tinkham Property Entry <LOD

11 Floor Ceramic Light Gray Tinkham Property Entry 0.1

12 Floor Ceramic Light Gray Tinkham Property Kitchen 0.08

13 Floor Ceramic Light Gray Tinkham Property Kitchen 0.08

14 Floor Ceramic Light Gray Tinkham Property Kitchen 0.04

15 Door Frame Wood White Tinkham Property Livingroom <LOD

16 Structural Beam Wood Dark Brown Tinkham Property Livingroom 0.02

17 Ceiling Wood Brown Tinkham Property Livingroom <LOD

18 Stairs Wood White Tinkham Property Loft <LOD

19 Guard Rail Wood Brown Tinkham Property Loft <LOD

20 Door Wood White Tinkham Property Master

Bedroom

<LOD

21 Floor Brick Red Tinkham Property Master

Bedroom

<LOD

22 Floor Ceramic Off White Tinkham Property Master

Bathroom 0.02

23 Shower Ceramic Off White Tinkham Property Master

Bathroom

<LOD

24 Shower Ceramic Gray Tinkham Property Master

Bathroom

<LOD

EHSI Project 11035 November 6th, 2017

TABLE 3

XRF SAMPLING

SUMMARY OF PAINTED COMPONENTS AND MATERIALS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

Read

Component Substrate Color Building Room Lead Conc.

(mg/cm2)

25 Wall Drywall White Tinkham Property Master

Bathroom

<LOD

26 Wall Drywall White Tinkham Property Interior <LOD

27 Wall Wood White Tinkham Property Interior <LOD

28 Door Metal White Tinkham Property Interior <LOD

29 Stairs Wood White Tinkham Property Interior <LOD

30 Baseboard Wood Black Tinkham Property Interior <LOD

31 Door Wood Brown Tinkham Property Exterior <LOD

32 Door Frame Wood Brown Tinkham Property Exterior <LOD

33 Door Trim Wood Brown Tinkham Property Exterior <LOD

34 Wall Trim Wood White Tinkham Property Exterior <LOD

35 Fascia Wood White Tinkham Property Exterior <LOD

36 Gutter Metal Green Tinkham Property Exterior <LOD

37 Roof Flashing Metal Green Tinkham Property Exterior <LOD

38 Roof Metal Green Tinkham Property Exterior <LOD

39 Downspout Metal Green Tinkham Property Exterior 0.3

40 Door Metal White Tinkham Property Exterior <LOD

41 Door Frame Wood White Tinkham Property Exterior <LOD

42 Door Trim Wood White Tinkham Property Exterior <LOD

43 Window Trim Wood White Tinkham Property Exterior <LOD

44 Wall Trim Wood Brown Tinkham Property Pump

House Ext.

<LOD

45 Wall Metal Light Gray Tinkham Property Garage

Interior

<LOD

46 Door Metal White Tinkham Property Garage

Interior

<LOD

47 Door Metal White Tinkham Property Garage

Interior

<LOD

48 Door Frame Wood White Tinkham Property Garage

Interior

<LOD

49 Door Metal White Tinkham Property Garage

Exterior

<LOD

50 Door Frame Wood White Tinkham Property Garage

Exterior

<LOD

51 Door Trim Wood White Tinkham Property Garage

Exterior

<LOD

52 Structural Beam Wood Dark Brown Tinkham Property Garage

Exterior

<LOD

53 Fascia Wood White Tinkham Property Garage

Exterior

<LOD

EHSI Project 11035 November 6th, 2017

TABLE 3

XRF SAMPLING

SUMMARY OF PAINTED COMPONENTS AND MATERIALS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

Read

Component Substrate Color Building Room Lead Conc.

(mg/cm2)

54 Wall Metal Light Gray Tinkham Property Garage

Exterior

<LOD

55 Roof Metal Dark Brown Tinkham Property Garage

Exterior 0.03

56 Wall Trim Wood White Tinkham Property Garage

Exterior

<LOD

57 Door Metal White Tinkham Property Garage

Exterior

<LOD

58 Downspout Metal Green Tinkham Property Garage

Exterior 0.34

59 NIST Check Wood Red Tinkham Property N/A 0.96

60 NIST Check Wood Red Tinkham Property N/A 0.92

61 NIST Check Wood Red Tinkham Property N/A 0.93

In addition to the XRF samples, EHSI collected two (2) bulk QA samples for laboratory analysis. The bulk sample results ranged from 0.0052 percent lead by weight to 0.0078 percent lead by weight. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations.

Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.

Copies of the analytical laboratory report and field data forms for lead paint are included in

Appendix B of this report.

TABLE 4

SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

SAMPLE

NUMBER

LOCATION

COMPONENT/

SUBSTRATE

COLOR

RESULTS

% Pb by

WT

11035-TIN-

Pb01

Main Floor, Master Bedroom Heater Pad/Brick

& Mortar Red & Gray 0.0052

11035-TIN-

Pb02 Basement, Exterior East Side

Fireplace/Stone &

Mortar Gray 0.0078

Key: Pb = lead, WT = weight

EHSI Project 11035 November 6th, 2017

DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.

Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.

2.4.3 Toxicity Characteristic Leaching Procedure Sampling

Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).

At the request of NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos Survey. The results of that lead-TCLP analysis indicate leachable lead present in the anticipated demolition waste stream at a concentration of <0.5 mg/L. A detailed list of the materials included in the TCLP sample are provided in Appendix F.

It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.

2.4.4 Polychlorinated Biphenyls

Ballasts EHSI inspected a representative number of each type of fluorescent fixture for PCB-containing ballasts. A select number of fixtures inspected were found to contain magnetic ballasts and must be assumed to contain PCB containing dialectic fluid; therefore, they must be disposed/recycled as Ecology Dangerous Waste. A Summary of ballasts and Hg-containing light tubes is provided in Table 5.

2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs

All fluorescent light tubes and CFL bulbs quantified in Table 5 contain Hg. Hg wastes are regulated as “universal wastes” under Ecology’s regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste. No Hg-containing switches or thermostats were identified in the structures.

TABLE 5

SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

LIGHT TYPE FIXTURES

TUBES/

BULBS

MAGNETIC

BALLASTS

4”x4’ Mounted light fixture w/ 2 bulbs and 1 magnetic ballast (in garage) 1 2 1

EHSI Project 11035 November 6th, 2017

TABLE 5

SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS

NATIONAL PARK SERVICE

LAKE CRESCENT – TINKHAM PROPERTY

LIGHT TYPE FIXTURES

TUBES/

BULBS

MAGNETIC

BALLASTS

6”x4’ Mounted light fixture w/ 1 bulb and 1 magnetic ballast (on underside of loose cabinet in garage)

1 1 1

Light fixture w/ 1 CFL bulb 1 1 0

Total Tinkham Property 3 4 2 Key: CFL = compact fluorescent light

3.0 LIMITATIONS

This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished; however, energized electrical panels, were not sampled but were assumed to have ACM internal components. All suspect materials present were accessible for sampling.

This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be

ACM by this survey report when encountered must be treated as ACM until sampled by a Certified AHERA Building Inspector and analyzed by a certified laboratory.

4.0 STANDARD OF CARE

The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.

5.0 CERTIFIED AHERA BUILDING INSPECTORS

The Certified AHERA Building Inspectors listed below surveyed on September 26th, 2017, in accordance with federal, state, and local requirements.

Rory Peterson Mike Ruark Certified AHERA Building Inspector Certified AHERA Building Inspector

Certificate Number: 1628987 Certificate Number: 163007

Expiration Date: August 23, 2018 Expiration Date: September 6, 2018

Appendix A

APPENDIX A

Asbestos Analytical Laboratory Report and Field Data Forms

Nick Ly, Technical Director

Client Project: 11035-01

Location: Tinkham Property

Dear Mr. Peterson, Enclosed please find test results for the 4 sample(s) submitted to our laboratory for analysis on

10/2/2017.

Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116

Method for the Determination of Asbestos in Bulk Building Materials.

For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.

For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.

The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%

Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.

Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.

Sincerely, Enc.: Sample Results

October 4, 2017

Nick L T hnical D

Rory Peterson

EHS International

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1717430.00

< Client:

Address:

Attention: Mr. Rory Peterson

Tinkham Property

Client Project #: 11035-01

Samples Received: 4

By Polarized Light Microscopy

Bulk Asbestos Fibers Analysis

EHS International

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Method: EPA/600/R-93/116

& EPA/600/M4-82-020

Samples Analyzed: 4

Project Location:

Batch #: 1717430.00

Date Received: 10/2/2017

17095333Lab ID: Client Sample #:

Location: Tinkham Property

11035-TIN-20QA

Layer 1 of 2 Description: White brittle material

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Binder/Filler, Calcareous binder 3%Cellulose None Detected ND

Layer 2 of 2 Description: Brown wood debris

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Wood flakes 34%Wood fibers None Detected ND

17095334Lab ID: Client Sample #:

Location: Tinkham Property

11035-TIN-23QA

Layer 1 of 3 Description: Gray cementitious material with fibrous material

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Binder/Filler, Cement/Binder 2%Cellulose None Detected ND

10%Glass fibers

Layer 2 of 3 Description: Gray compressed fibrous material

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Binder/Filler 70%Cellulose None Detected ND

Layer 3 of 3 Description: Black asphaltic fibrous material with debris

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Asphalt/Binder, Binder/Filler, Wood flakes 66%Cellulose None Detected ND

4%Wood fibers

17095335Lab ID: Client Sample #:

Location: Tinkham Property

11035-TIN-51QA

Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA

600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL

Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government

Client

Lori TsengAnalyzed by:

Nick LyReviewed by:

10/04/2017 Date:

10/04/2017Date:

Sampled by:

< Client:

Address:

Attention: Mr. Rory Peterson

Tinkham Property

Client Project #: 11035-01

Samples Received: 4

By Polarized Light Microscopy

Bulk Asbestos Fibers Analysis

EHS International

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Method: EPA/600/R-93/116

& EPA/600/M4-82-020

Samples Analyzed: 4

Project Location:

Batch #: 1717430.00

Date Received: 10/2/2017

Layer 1 of 1 Description: Black asphaltic fibrous felt

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Asphalt/Binder, Binder/Filler 74%Cellulose None Detected ND

17095336Lab ID: Client Sample #:

Location: Tinkham Property

11035-TIN-69QA

Layer 1 of 1 Description: Black asphaltic fibrous felt

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Asphalt/Binder, Binder/Filler 78%Cellulose None Detected ND

Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA

600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL

Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government

Client

Lori TsengAnalyzed by:

Nick LyReviewed by:

10/04/2017 Date:

10/04/2017Date:

Sampled by:

EHS International 1717430.00

Company NVL Batch Number

Total Number of Samples

Tinkham Property

5 DaysTAT

10/9/2017Due Date 10:40 AMTime

(206) 254-4279Fax roryp@ehsintl.comEmail

Project Manager Mr. Rory Peterson

(206) 381-1128

(425) 766-8342Cell

Phone

Rush Samples

Rush TAT

NoAH

11035-01Project Name/Number: Project Location:

Sample ID Description A/RLab ID

ASBESTOS LABORATORY SERVICES

Subcategory

Item Code

PLM Bulk

Metals

ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Address

11035-TIN-20QA1 A17095333

11035-TIN-23QA2 A17095334

11035-TIN-51QA3 A17095335

11035-TIN-69QA4 A17095336

Office Use Only Print Name Company Date TimeSignature

Faxed Emailed

Company Date TimeSignature

ClientSampled by

Umer KhanReceived by

ClientRelinquished by

Lori TsengAnalyzed by

Results Called by

NVL

NVL

10/2/17

10/4/17

Print Name

Entered By: Umer Khan

Date: 10/2/2017

Time: 11:05 AM

Special

Instructions:

Appendix B

APPENDIX B

Lead Laboratory Reports and Field Data Forms

RE: Metals Analysis; NVL Batch # 1717428.00

Dear Mr. Peterson, October 5, 2017

EHS International

Rory Peterson

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Enclosed please find the test results for samples submitted to our laboratory for analysis.

Preparation of these samples was conducted following protocol outlined in EPA Method SW 846

-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.

For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.

For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.

This report is considered highly confidential and will not be released without your approval.

Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.

Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.

Sincerely, Shalini Patel, Laboratory Analyst

Analysis Report Total Lead (Pb)

Tinkham Property

EHS InternationalClient:

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Mr. Rory PetersonAttention:

Address:

Project Location: Samples Received: 2

Samples Analyzed: 2

Client Project #: 11035-01

Batch #: 1717428.00

Date Received: 10/2/2017

Lab ID Client Sample #

Sample

Weight (g)

Results in mg/Kg

Resul…