Attchmt 18_Option 3-Hopkins Property Report.pdf
PDF 10 MB Posted
- Attached to
- Hazardous Materials Abatement, OLYM
- Solicitation number
- 140P8318Q0051
About this file
Attachment 18 - lead and asbestos survey report for optional Hopkins property site
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1011 SW Klickitat Way, Suite 104, Seattle, Washington 98134
Phone 206-381-1128
Toll Free 800-666-2959
Fax 206-254-4279
Environmental Consulting
Hazardous Materials Management
Industrial Hygiene Services
Construction Management
Indoor Air Quality
LIMITED LEAD AND ASBESTOS SURVEY REPORT
NATIONAL PARK SERVICE - OLYMPIC NATIONAL PARK
LAKE QUINAULT - HOPKINS PROPERTY
606 North Shore Road Amanda Park, Washington 98526
November 17th, 2017
Prepared For:
Jeff Doryland Deputy Chief of Facility Management
Olympic National Park
600 E. Park Avenue, Port Angeles, WA 98273 ii
Limited Lead and Asbestos Survey Report
National Park Service – Olympic National Park
Lake Quinault - Hopkins Property
606 North Shore Road
Amanda Park, Washington
EHSI Project No.: # 11035
The material and data in this report were prepared under the supervision and direction of the undersigned.
Tim Nickell Lead AHERA Building Inspector
Derica Escamilla
Principal of Hazardous Materials Services iii
TABLE OF CONTENTS
Acronym List ....................................................................................iv
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
1.2 EXTENT OF CURRENT SURVEY
1.3 ACM MATERIALS FOUND
1.4 OPINIONS AND RECOMMENDATIONS
1.5 LIMITATIONS/DISCLAIMER
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
2.2 BUILDING DESCRIPTION
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
2.3.2 Lead-Containing Paint/Lead-Containing Materials
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
2.4.2 Lead-Containing Paint and Building Materials
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
2.4.4 Polychlorinated Biphenyls
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
3.0 LIMITATIONS
4.0 STANDARD OF CARE
5.0 CERTIFIED AHERA BUILDING INSPECTORS
APPENDICES
A ........................ Asbestos Laboratory Reports and Field Data Forms
B ........................ Lead Laboratory Reports and Field Data Forms C ........................Certified AHERA Building Inspector Certificates D ........................ Laboratory Certifications for Asbestos and Lead Analysis
E......................... Sample Location Drawings for Asbestos, Lead, and TCLP F......................... Lead TCLP Laboratory Reports and Field Data Forms
G ........................ Abatement Cost Estimate iv
ACRONYM LIST
ACM .......................Asbestos-Containing Material
AHERA ....................Asbestos Hazard Emergency Response Act
AIHA ......................American Industrial Hygiene Association
CFL ........................Compact Fluorescent Light
CFR ........................Code of Federal Regulations
CMU .......................Concrete Masonry Unit
DOSH .....................Washington State Department of Labor and Industries, Division of
Occupational Safety and Health
EA..........................Each
Ecology...................Washington State Department of Ecology
EHSI.......................EHS-International, Inc.
ELLAP .....................Environmental Lead Laboratory Accreditation Program
GWB.......................Gypsum Wall Board
Hg..........................Mercury
HID ........................High Intensity Discharge
JC ..........................Joint Compound
LCM........................Lead-Containing Material
LCP ........................Lead-Containing Paint
LF ..........................Linear Feet
L&I.........................Washington State Department of Labor and Industries mg/cm2...................Milligrams Per Square Centimeter mg/L ......................Milligrams Per Liter
N/A ........................Not Applicable
ND .........................None Detected
NVL ........................NVL Laboratories, Inc.
NVLAP ....................National Voluntary Laboratory Accreditation Program
OD .........................Outside Diameter
OSHA .....................US Occupational Safety and Health Administration
ORCAA....................Olympic Region Clean Air Agency
Pb ..........................Lead
PCBs.......................Polychlorinated Biphenyls
PLM ........................Polarized Light Microscopy ppm .......................Parts per Million
QA .........................Quality Assurance
RCW.......................Revised Code of Washington
SAT ........................Seattle Asbestos Test, LLC
TCLP.......................Toxicity Characteristic Leaching Procedure
VCT ........................Vinyl Composite Tile
WAC.......................Washington Administrative Code
WT .........................Weight w/ ..........................With
XRF ........................x-ray fluorescence
NPS – Lake Quinault - Hopkins Property
EHSI Project 11035
November 17th, 2017
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
The National Park Service (NPS) plans to demolish the existing structures on the Hopkins
Property located on Lake Quinault at 606 North Shore Road, Amanda Park, Washington. The
NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Hopkins
Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure (TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl (PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:
interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.
1.3 ACM MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION
Non-ACM gray/brown fibrous material on ACM white caulking
(around smokestack ceiling penetration) [Sample # 23] Kitchen
ACM black window glazing gasket (on 2’x3’6” metal window)
[Sample # 25] Kitchen
Non-ACM silver paint on non-ACM gray/white sealant on ACM black asphaltic tar (on sheet metal roof at seam between high
& low angle roof sections) [Sample # 43]
Exterior Roof
KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, w/ = with
1.4 OPINIONS AND RECOMMENDATIONS
The project includes demolition of the existing structures at the Hopkins Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.
EHSI Project 11035
November 17th, 2017
Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).
One fluorescent light fixture inspected was found to have a magnetic ballast which is assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. The magnetic ballasts must be removed from the fixture and disposed of as Washington Department of
Ecology (Ecology) Dangerous Waste. All fluorescent light tubes contain mercury; any fluorescent tubes to be disturbed during the project must be recycled as (Ecology) Universal
Waste.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. This report and accompanying appendices include the supporting information for this executive summary.
EHSI Project 11035
November 17th, 2017
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
The NPS plans to demolish the existing structures at the Hopkins Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:
identification of all suspect materials; a determination of whether suspect materials were:
ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.
On October 12th and 13th, 2017, EHSI conducted a Limited Lead and Asbestos Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of
Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington
Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region
Clean Air Agency (ORCAA).
2.2 BUILDING DESCRIPTION
The Hopkins Property is located on Lake Quinault at 606 North Shore Road, Amanda Park, Washington. Structures on the property include a single-story residential house with loft.
Three exterior storage sheds are attached to the residence by the exterior deck.
The residence is a wood-framed structure with post and pillar foundation on cinderblock footings and wood siding. The roof is constructed of plywood and asphaltic vapor barrier under a sheet metal surface. Interior floor finishes include: Wood laminate and painted plywood.
Interior wall finishes include: wood panels and gypsum wallboard (GWB). Interior ceilings are all plywood. Windows are vinyl or metal-framed and operable. Heating was formerly provided by a wood stove in the residence. No hot water system components were observed on the
Property. Interior lighting consists of incandescent and fluorescent ceiling fixtures and natural light from the windows.
The detached covered structure to the west of the residence consists of wood pillars and siding. A manually operated water well is located to the northeast of the residence.
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of
Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix
C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October
1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
EHSI Project 11035
November 17th, 2017
EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and
Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary
Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.
Copies of both laboratories’ NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used an Olympus Delta-Pro x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial
Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program
(ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Forty-three (43) bulk samples of suspect ACM were collected as part of the survey. Three (3) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The
ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. All suspect materials were accessible for sampling.
EHSI Project 11035
November 17th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOPKINS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOP-01
Kitchen
Hard gray sealant (between gap in laminate wood floor)
ND N/A
11035-
HOP-02
Living
Room
Layer 1: Light gray caulking
(between laminate and plywood)
Layer 2: White leveling compound
Layer 3: Plywood
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOP-03
Living
Room
Layer 1: Brown/white laminate wood flooring
Layer 2: Brown flooring layer
Layer 3: Tan laminate backing
Layer 4: Clear yellow mastic
Layer 5: White levelling compound
(on particle board)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A
N/A
N/A
N/A
11035-
HOP-04
Kitchen
Layer 1: Brown/white laminate wood flooring
Layer 2: Brown flooring layer
Layer 3: Tan laminate backing
Layer 4: Blue foam
Layer 5: Transparent plastic
Layer 6: Brown VCT
Layer 7: Clear mastic (on particle board)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11035-
HOP-05
Closet
Layer 1: Brown/white laminate wood flooring
Layer 2: Brown flooring layer
Layer 3: Tan laminate backing
Layer 4: Clear blue plastic
Layer 5: Brown vinyl layer
Layer 6: Brown VCT
Layer 7: Clear mastic (on particle board)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
N/A
N/A
N/A
N/A
N/A
N/A
11035-
HOP-07
Kitchen
Layer 1: 12” x 12” Green and white ceramic tile (fireplace backdrop and floor)
Layer 2: White grout
Layer 3: Gray mortar
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOP-08
Bedroom
Layer 1: Pink fiberglass batt insulation (in wall)
Layer 2: Black mastic
Layer 3: Brown paper vapor barrier
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOP-09
Living
Room
Layer 1: Yellow fiberglass batt insulation (in wall)
Layer 2: Black mastic
Layer 3: Brown paper vapor barrier
L1: ND
L2: ND
L3: ND
N/A
N/A
EHSI Project 11035
November 17th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOPKINS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOP-10
Living
Room
Layer 1: White JC w/ paint
Layer 2: Yellow mesh joint tape
Layer 3: Green joint tape
Layer 4: GWB wall w/ paper
(corner)
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A
N/A
11035-
HOP-11
Living
Room
White GWB wall w/ paint and paper
(mid-wall)
ND N/A
11035-
HOP-12
Living
Room
White GWB wall w/ paint and paper
(mid-wall)
ND N/A
11035-
HOP-13
Kitchen
Layer 1: Light gray window frame caulking (around 4’6”x3’6” vinyl-framed windows)
Layer 2: Wood wall frame
L1: ND
L2: ND
N/A
N/A
11035-
HOP-
14QA
Living
Room
Clear/beige yellow window frame caulking (on 4’x5’ vinyl-framed windows)
ND N/A
11035-
HOP-15
Living
Room
Layer 1: Black/gray vinyl weather stripping
Layer 2: Trace clear mastic
Layer 3: Gray foam
Layer 4: Black plastic backing
Layer 5: Trace clear mastic
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A
N/A
N/A
N/A
11035-
HOP-16
Bedroom
Layer 1: White window frame caulking (around 3’x3’6” vinyl-framed windows)
Layer 2: Wood wall frame
L1: ND
L2: ND
N/A
N/A
11035-
HOP-17
Bedroom
Black window glazing gasket (on
5’x4’ metal-framed window)
ND N/A
11035-
HOP-18
Kitchen
Tan fire brick (from wood burning stove)
ND N/A
11035-
HOP-19
Kitchen
Layer 1: White paper w/ mastic
Layer 2: Black/gray foam weather stripping
Layer 3: Trace clear mastic
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOP-20
Bedroom
Layer 1: Wood walls
Layer 2: Dark brown/brown wood patching compound (wall patch)
L1: ND
L2: ND
N/A
N/A
11035-
HOP-21
Kitchen
Silver/clear sealant (on fireplace smokestack)
ND N/A
11035-
HOP-22
Kitchen
White/gray insulation (inside fireplace smokestack)
ND N/A
EHSI Project 11035
November 17th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOPKINS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
HOP-23
Kitchen
Layer 1: Gray/brown fibrous material
Layer 2: White caulking
(around smokestack ceiling penetration)
L1: ND
L2: 4%
N/A
Chrysotile
11035-
HOP-24
Kitchen
Layer 1: White/gray paper sink drain gasket
Layer 2: Black rubber gasket
L1: ND
L2: ND
N/A
N/A
11035-
HOP-25
Kitchen
Black window glazing gasket
(on 2’x3’6” metal-framed window)
3% Chrysotile
11035-
HOP-26
Closet
Black plastic electrical panel component (in 1’x2’ electrical panel)
ND N/A
11035-
HOP-28
Kitchen
Layer 1: White plastic cabinet cover
Layer 2: Trace clear mastic
Layer 3: Wood cabinet
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
HOP-29
Kitchen
Beige mastic (under cement countertops)
ND N/A
11035-
HOP-30
Loft
Blue/green/brown coating/sealant
(on seams of plywood roof decking)
ND N/A
EXTERIOR AND ROOF
11035-
HOP-32
Roof over
Deck
Black asphaltic vapor barrier (under sheet metal roofing)
ND N/A
11035-
HOP-
33QA
Roof over
House
Black asphaltic vapor barrier (under sheet metal roofing)
ND N/A
11035-
HOP-34
Exterior Gray CMU block ND N/A
11035-
HOP-35
Exterior
White window glazing gasket (on
4’x3’ vinyl-framed windows)
ND N/A
11035-
HOP-36
Exterior
Closet
Gray window glazing gasket (on
3’x2’ metal-framed windows)
ND N/A
11035-
HOP-37
Exterior
White window frame caulking (on
2’x2’6” vinyl-framed window)
ND N/A
11035-
HOP-38
Exterior
Light gray rubbery window screen gasket (w/ metal frame on 2’x3’6” vinyl-framed window)
ND N/A
11035-
HOP-43
Exterior
Roof at seam between roof sections
Layer 1: Silver paint
Layer 2: Gray/white sealant
Layer 3: Black asphaltic tar (on sheet metal roofing at seam between high & low angle roof sections)
L1: ND
L2: ND
L3: 3%
N/A
Chrysotile
EHSI Project 11035
November 17th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
HOPKINS PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
EXTERIOR SHED AND WATER WELL
11035-
HOP-06
Storage
Shed
Layer 1: Black rubber mat
Layer 2: White woven mesh
Layer 3: Black rubber mat
Layer 4: White woven mesh
Layer 5: Black rubber mat
Layer 6: White woven mesh
Layer 7: Black rubber mat
(mechanically fastened to wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
L6: ND
L7: ND
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11035-
HOP-27
Water well
4” OD black rubber gasket (on well pump)
ND N/A
11035-
HOP-31
Storage
Shed Silver paint roof sealant (in bucket) ND N/A
11035-
HOP-39
Storage
Shed
Light gray rubbery window glazing gasket (on 1’x1’ metal-framed window)
ND N/A
11035-
HOP-40
Storage
Shed
Black rubber window screen gasket
(w/ metal frame on 2’x3’6” vinyl-framed window)
ND N/A
11035-
HOP-
41QA
Detached
Outdoor
Covered
Area
Gray sealant (on black rubber mat roof)
ND N/A
11035-
HOP-42
Water well
Layer 1: White sealant (on 3” OD metal pipe)
Layer 2: Wood
L1: ND
L2: ND
N/A
N/A KEY: bold = bold text indicates asbestos-containing layer, CMU = concrete masonry unit, GWB = gypsum wall board, JC = joint compound, ND = non-detect, N/A = not applicable, OD = outer diameter, VCT = vinyl composite tile, w/ = with
Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2
Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
Non-ACM gray/brown fibrous material on ACM white caulking (around smokestack ceiling penetration)
[Sample # 23]
Kitchen 3 LF
EHSI Project 11035
November 17th, 2017
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
ACM black window glazing gasket (on 2’x3’6” and
3’x2’ metal-framed windows) [Sample # 25] Kitchen 3 EA
Non-ACM silver paint on non-ACM gray/white sealant on
ACM black asphaltic tar (on sheet metal roof at seam between high & low angle roof sections) [Sample # 43]
Exterior Roof 160 LF
KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, EA = each, LF = linear feet, w/ = with
ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect
ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building
Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.
2.4.2 Lead-Containing Paint and Building Materials
Thirty-five (35) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer.
XRF paint sample results ranged from greater than or equal to 5.0 milligrams of lead per square centimeter (mg Pb/cm2) to <LOD. Bolded results indicate materials coated with
“lead-based paint” (e.g., >1.0 mg/cm2) as defined by USEPA regulation 40CFR745 and Washington State Commerce regulation WAC 365-230. The results are provided in
Table 3 of this report.
Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
Read
Component Substrate Color Building Room
Lead
Conc.
(mg/cm2)
1 NIST Check N/A Red Hopkins Property Calibration 1.2
2 NIST Check N/A Red Hopkins Property Calibration 1.11
3 NIST Check N/A Red Hopkins Property Calibration 1.17
EHSI Project 11035
November 17th, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
4 Wall Drywall Blue Hopkins Property Livingroom < LOD
5 Floor Wood Beige Hopkins Property Livingroom < LOD
6 Window Frame Plastic White Hopkins Property Livingroom < LOD
7 Floor Fiber Board Light Brown Hopkins Property Kitchen < LOD
8 Fireplace Mantle Metal Black Hopkins Property Kitchen 0.02
9 Fireplace Mantle Ceramic Off White Hopkins Property Kitchen 0.01
10 Fireplace Mantle Ceramic Off White Hopkins Property Kitchen 0.01
11 Fireplace Mantle Ceramic Blue Hopkins Property Kitchen < LOD
12 Fireplace Mantle Metal Black Hopkins Property Kitchen 0.01
13 Wall Trim Metal Black Hopkins Property Kitchen < LOD
14 Counter Concrete Dark Gray Hopkins Property Kitchen < LOD
15 Sink Metal Silver Hopkins Property Kitchen < LOD
16 Cabinet Wood Blue Hopkins Property Kitchen < LOD
17 Window Frame Metal Brown Hopkins Property Master
Bedroom
< LOD
18 Window Frame Plastic White Hopkins Property Master
Bedroom
< LOD
19 Door Metal White Hopkins Property Livingroom < LOD
20 Door Metal Green Hopkins Property Livingroom < LOD
21 Door Metal Beige Hopkins Property Livingroom < LOD
22 Door Frame Wood White Hopkins Property Exterior < LOD
23 Roof Flashing Metal Dark Green Hopkins Property Exterior 0.07
24 Roof Metal Dark Green Hopkins Property Exterior < LOD
25 Window Frame Metal Brown Hopkins Property Exterior 0.01
26 Door Trim Metal Dark Green Hopkins Property Exterior 0.01
27 Gutter Metal Dark Green Hopkins Property Exterior < LOD
28 Wall Wood Brown Hopkins Property Exterior < LOD
29 Fume Hood Metal Dark Green Hopkins Property Exterior 0.14
30 Electrical Box Metal Gray Hopkins Property Exterior < LOD
31 Wall Drywall Light Blue Hopkins Property Livingroom < LOD
32 NIST Check N/A Red Hopkins Property Livingroom 1.22
33 NIST Check N/A Red Hopkins Property Livingroom 1.29
34 NIST Check N/A Red Hopkins Property Livingroom 1.14
35 NIST Check N/A Red Hopkins Property Livingroom 1.25
57 Wall Wood Light Blue Storage Sheds Outbuilding 1
Ext 0.24
58 Wall Wood Red Storage Sheds Outbuilding 1
Ext 0.26
EHSI Project 11035
November 17th, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
59 Door Trim Wood White Storage Sheds Outbuilding 1
Ext
< LOD
60 Door Trim Wood Light Gray Storage Sheds Outbuilding 1
Ext
< LOD
61 Floor Concrete Light Gray Storage Sheds Outbuilding 2
Ext
< LOD
62 Wall Metal Light Blue Storage Sheds Outbuilding 2
Ext 0.01
63 Wall Trim Metal White Storage Sheds Outbuilding 2
Ext 0.01
64 NIST Check Drywall Red N/A N/A 1.07
65 NIST Check Drywall Red N/A N/A 1.08
66 NIST Check Drywall Red N/A N/A 1.01
67 NIST Check Drywall Red N/A N/A 1.1
In addition to the XRF samples, EHSI collected two (2) bulk QA samples for laboratory analysis. The bulk sample results were both less than the reporting limit. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations.
Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.
Copies of the analytical laboratory report and field data forms for lead paint are included in
Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
SAMPLE
NUMBER
LOCATION
COMPONENT/
SUBSTRATE
COLOR
RESULTS
% Pb by
WT
11035-HOP-
Pb01 House, Kitchen Fireplace
Ceramic tile with mortar and grout Green <0.0026
11035-HOP-
Pb02 House, Exterior Foundation CMU Gray <0.0036
Key: CMU = concrete masonry unit, Pb = lead, WT = weight
DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to
EHSI Project 11035
November 17th, 2017 determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).
At the request of NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos
Survey. The results of that lead-TCLP analysis indicate no leachable lead was present in the anticipated demolition waste stream above the laboratories reporting limit at a concentration of <0.5 mg/L. A detailed list of the materials included in the TCLP sample are provided in
Appendix F.
It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.
2.4.4 Polychlorinated Biphenyls
Ballasts
EHSI inspected each type of fluorescent fixture for PCB-containing ballasts. One fixture inspected was found to contain a magnetic ballast and must be assumed to contain PCB containing dialectic fluid; therefore, it must be disposed/recycled as Ecology Dangerous
Waste. A Summary of ballasts and Hg-containing light tubes is provided in Table 5.
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
All fluorescent light tubes quantified in Table 5 contain Hg. Hg wastes are regulated as
“universal wastes” under Ecology’s regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste.
TABLE 5
SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS
NATIONAL PARK SERVICE
LAKE QUINAULT – HOPKINS PROPERTY
LIGHT TYPE FIXTURES
TUBES/
BULBS
MAGNETIC
BALLASTS
4’x 1’ Suspended light fixture w/ 2 bulbs and
1 magnetic ballast 1 2 1
Total Hopkins Property 1 2 1
EHSI Project 11035
November 17th, 2017
3.0 LIMITATIONS
This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished. All suspect materials present were accessible for sampling.
This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be
ACM by this survey report when encountered must be treated as ACM until sampled by a
Certified AHERA Building Inspector and analyzed by a certified laboratory.
4.0 STANDARD OF CARE
The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.
5.0 CERTIFIED AHERA BUILDING INSPECTORS
The Certified AHERA Building Inspectors listed below surveyed on October 12th and 13th, 2017, in accordance with federal, state, and local requirements.
Tim Nickell Mike Ruark
Certified AHERA Building Inspector Certified AHERA Building Inspector
Certificate Number: 1628878 Certificate Number: 163007
Expiration Date: August 10, 2018 Expiration Date: September 6, 2018
Appendix A
APPENDIX A
Asbestos Analytical Laboratory Report and Field Data Forms
Lori Tseng, Laboratory Analyst
Client Project: 11035-02
Location: Hopkins Property
Dear Mr. Peterson, Enclosed please find test results for the 3 sample(s) submitted to our laboratory for analysis on
10/18/2017.
Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116
Method for the Determination of Asbestos in Bulk Building Materials.
For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.
For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.
The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results
October 25, 2017
Lori T Labo to A lyst
Rory Peterson
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1718555.00
< Client:
Address:
Attention: Mr. Rory Peterson
Hopkins Property
Client Project #: 11035-02
Samples Received: 3
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 3
Project Location:
Batch #: 1718555.00
Date Received: 10/18/2017
17101330Lab ID: Client Sample #:
Location: Hopkins Property
11035-HOP-14QA
Layer 1 of 1 Description: Beige soft elastic material (on wood)
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Caulking compound <1%Cellulose None Detected ND
17101331Lab ID: Client Sample #:
Location: Hopkins Property
11035-HOP-33QA
Layer 1 of 1 Description: Black asphaltic fibrous felt
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Asphalt/Binder, Binder/Filler, Fine particles 67%Cellulose None Detected ND
2%Spider silk
17101332Lab ID: Client Sample #:
Location: Hopkins Property
11035-HOP-41QA
Layer 1 of 1 Description: Gray soft material
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Fine particles NDNone Detected None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Welly HsiehAnalyzed by:
Lori TsengReviewed by:
10/24/2017 Date:
10/25/2017Date:
Sampled by:
Lori Tseng, Laboratory Analyst
EHS International 1718555.00
Company NVL Batch Number
Total Number of Samples
Hopkins Property
5 DaysTAT
10/25/2017Due Date 9:40 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-02Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals
ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-HOP-14QA1 A17101330
11035-HOP-33QA2 A17101331
11035-HOP-41QA3 A17101332
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Welly HsiehAnalyzed by
Results Called by
NVL
NVL
10/18/17
10/24/17
Print Name
Entered By: Soumeya Benzina
Date: 10/18/2017
Time: 1:18 PM
Special
Instructions:
Appendix B
APPENDIX B
Lead Laboratory Reports and Field Data Forms
RE: Metals Analysis; NVL Batch # 1718536.00
Dear Mr. Peterson, October 19, 2017
EHS International
Rory Peterson
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.
This report is considered highly confidential and will not be released without your approval.
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.
Sincerely, Nick Ly, Technical Director
Analysis Report Total Lead (Pb)
Hopkins Property
EHS InternationalClient:
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Mr. Rory PetersonAttention:
Address:
Project Location: Samples Received: 2
Samples Analyzed: 2
Client Project #: 11035-02
Batch #: 1718536.00
Date Received: 10/18/2017
Lab ID Client Sample #
Sample
Weight (g)
Results in mg/Kg
Results in percent
RL in mg/Kg
Matrix: Bulk
Method: EPA 3051/7000B
17101213 11035-HOP-Pb01 0.3834 26 < 26 0.0026<
17101214 11035-HOP-Pb02 0.2760 36 < 36 0.0036<
ClientSampled by:
Yasuyuki HidaAnalyzed by:
Nick LyReviewed by:
10/19/2017Date Analyzed:
10/19/2017Date Issued:
Bench Run No: 2017-1019-5 mg/ Kg =Milligrams per kilogram RL = Reporting Limit
Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit Note : Method QC results are acceptable unless stated otherwise.
Unless otherwise indicated, the condition of all samples was acceptable at time of receipt.
EHS International 1718536.00
Company NVL Batch Number
Total Number of Samples
Hopkins Property
5 DaysTAT
10/25/2017Due Date 9:40 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-02Project Name/Number: Project Location:
Sample ID Description A/RLab ID
LEAD LABORATORY SERVICES
Subcategory
Item Code
Flame AA (FAA)
Metals
FAA-02 EPA 7000B Lead by FAA <paint>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-HOP-Pb011 A17101213
11035-HOP-Pb022 A17101214
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Yasuyuki HidaAnalyzed by
Results Called by
NVL
NVL
10/18/17
10/19/17
Print Name
Entered By: Mohammed Jamal
Date: 10/18/2017
Time: 11:31 AM
Special
Appendix C
APPENDIX C
Certified AHERA Building Inspector Certificates
Appendix D
APPENDIX D
Laboratory Certifications for Asbestos and
Lead Analysis
AIHA Laboratory Accreditation Programs, LLC acknowledges that
NVL Laboratories, Inc.
4708 Aurora Avenue N., Seattle, WA 98103
Laboratory ID: 101861 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation
Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: June 01, 2019
ENVIRONMENTAL LEAD Accreditation Expires: June 01, 2019
ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: June 01, 2019
FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires: June 01, 2019
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC
17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA-
LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
William Walsh, CIH
Chairperson, Analytical Accreditation Board
Cheryl O. Morton
Managing Director, AIHA Laboratory Accreditation Programs, LLC
Revision 15: 03/30/2016 Date Issued: 05/31/2017
Effective: 04/10/2015
101861_Scope_IHLAP_2017_05_31
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
Industrial Hygiene Laboratory Accreditation Program (IHLAP)
Initial Accreditation Date: 04/01/1997
IHLAP Scope
Category
Field of Testing (FoT)
(FoTs cover all relevant
IH matrices)
Technology sub-type/
Detector
Published Reference
Method/Title of In-house Method
Method Description or Analyte (for internal methods only)
Spectrometry Core
Inductively-Coupled
Plasma
ICP/AES
EPA 3051
NIOSH 7300 Modified
X-ray Diffraction (XRD) NIOSH 7500
Asbestos/Fiber
Microscopy Core
Phase Contrast
Microscopy (PCM)
NIOSH 7400
Miscellaneous Core Gravimetric NIOSH 0500 Modified
NIOSH 0600 Modified
A complete listing of currently accredited Industrial Hygiene laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org
Effective: 10/14/2016
Scope_ELLAP_R7
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
The EPA recognizes the AIHA-LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory
Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air and composited wipes analyses are not included as part of the NLLAP.
Environmental Lead Laboratory Accreditation Program (ELLAP)
Initial Accreditation Date: 02/07/1997
A complete listing of currently accredited Environmental Lead laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org
Field of Testing (FoT) Technology sub-type/
Detector Method
Method Description (for internal methods only)
Paint
EPA SW-846 3051
EPA SW-846 7000B
Soil
EPA SW-846 3051
EPA SW-846 7000B
Settled Dust by Wipe
EPA SW-846 3051
EPA SW-846 7000B
Airborne Dust
EPA SW-846 3051
NIOSH 7082
Effective: 03/12/2013
101861_Scope_EMLAP_2017_05_31
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
Environmental Microbiology Laboratory Accreditation Program (EMLAP)
Initial Accreditation Date: 02/01/1997
EMLAP Category Field of Testing
(FoT) Method Method Description
(for internal methods only)
Fungal
Air - Direct
Examination SOP 12.133 In-House: Analysis of Spore Trap
Bulk - Direct
Examination SOP 12.133 In-House: Bulk Analysis
Surface - Direct
Examination SOP 12.133 In-House: Surface Analysis
A complete listing of currently accredited Environmental Microbiology laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org
Effective: 08/29/2014
Scope_UniqueScopes_R1
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
Unique Scopes Laboratory Accreditation Program (Unique Scopes)
Initial Accreditation Date: 04/01/2013
A complete listing of currently accredited Unique Scope laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org
Unique Scope Category Field of Testing (FoT) Method Method Description
(for internal methods only)
Consumer Product Testing
Lead in Paint and Other
Similar Surface Coatings
CPSC-CH-E1003-09.1
Total Lead in Metal
Children’s Products
CPSC-CH-E1001-08.2
Total Lead in Non-Metal
Children’s Products
CPSC-CH-E1002-08.1
Appendix E
APPENDIX E
Sample Location Drawings for Asbestos, Lead, and TCLP
KITCHEN LIVING ROOMBEDROOM
DECK CLOSET
DECK
DECK
STORAGE
WELL
DECK
DECK
COVERED AREA
SHED
SL-1
HOPKINS
HOUSE
PROJECT NORTH
HOPKINS HOUSE
NOT TO SCALE
EHSI PROJECT #:
SCALE:
SURVEY DATES:
DRAWN BY:
INSPECTORS:
PROJECT MANAGER:
ISSUE DATE:
H O
P K
IN
S
P R
O P
E R
TY
N
O R
TH
S
H O
R E
R D
Q U
IN
A
U
LT
, W A
U S
D E
P A
R
TM
E N
T O
F
TH
E
IN
TE
R
IO
R
N P
S P
O R
T A
N G
E
LE
S , W
A
GENERAL NOTES
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT
THE SAMPLED MATERIALS.
1011 SW Klickitat Way, Suite 104
Seattle, Washington 98134
Ph: 206.381.1128
Fax: 206.254.4279
EHS-International, Inc.
SAMPLE LEGEND
BULK ASBESTOS SAMPLE LOCATIONS11035-HOP-XX
P R
O
JE
C T
P R
O P
E R
T Y
I D
S A
M P
L E
# PROPERTY ID:
HOP = HOPKINS PROPERTY
BULK LEAD SAMPLE LOCATIONS11035-HOP-PbXX
BULK TCLP SUB-SAMPLE11035-HOP-TCLP-XXA
11035-HOP-39
11035-HOP-05
11035-HOP-38
11035-HOP-24
11035-HOP-29
11035-HOP-37
11035-HOP-09
11035-HOP-10
11035-HOP-01
11035-HOP-34
11035-HOP-15
11035-HOP-14
11035-HOP-33
11035-HOP-32
11035-HOP-41
11035-HOP-26
11035-HOP-36
11035-HOP-31
11035-HOP-06
11035-HOP-27
11035-HOP-17
11035-HOP-20
11035-HOP-08
11035-HOP-16
11035-HOP-18
11035-HOP-07
11035-HOP-13
11035-HOP-25
11035-HOP-19
11035-HOP-43
11035-HOP-28
11035-HOP-42
11035-HOP-40
11035-HOP-12
11035-HOP-35
11035-HOP-Pb02
11035-HOP-02
11035-HOP-03
11035-HOP-04
11035-HOP-Pb01
11035-HOP-21
11035-HOP-22
11035-HOP-23
11035-HOP-TCLP-01A
11035-HOP-TCLP-01I
11035-HOP-TCLP-X
11035-HOP-TCLP-01L
11035-HOP-TCLP-01C
11035-HOP-TCLP-01G
11035-HOP-TCLP-01J
11035-HOP-TCLP-01K
11035-HOP-TCLP-01B
11035-HOP-TCLP-01D
11035-HOP-TCLP-01F
11035-HOP-TCLP-01E
Appendix F
APPENDIX F
Lead TCLP Laboratory Reports and Field Data Forms
RE: Metals Analysis; NVL Batch # 1718518.00
Dear Mr. Peterson, October 25, 2017
EHS International
Rory Peterson
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory…
This is the start of the file's text. The full file is on GovTribe.