1011 SW Klickitat Way, Suite 104, Seattle, Washington 98134

Phone 206-381-1128

Toll Free 800-666-2959

Fax 206-254-4279

Environmental Consulting

Hazardous Materials Management

Industrial Hygiene Services

Construction Management

Indoor Air Quality

LIMITED LEAD AND ASBESTOS SURVEY REPORT

NATIONAL PARK SERVICE - OLYMPIC NATIONAL PARK

LAKE QUINAULT - HOPKINS PROPERTY

606 North Shore Road Amanda Park, Washington 98526

November 17th, 2017

Prepared For:

Jeff Doryland Deputy Chief of Facility Management

Olympic National Park

600 E. Park Avenue, Port Angeles, WA 98273 ii

Limited Lead and Asbestos Survey Report

National Park Service – Olympic National Park

Lake Quinault - Hopkins Property

606 North Shore Road

Amanda Park, Washington

EHSI Project No.: # 11035

The material and data in this report were prepared under the supervision and direction of the undersigned.

Tim Nickell Lead AHERA Building Inspector

Derica Escamilla

Principal of Hazardous Materials Services iii

TABLE OF CONTENTS

Acronym List ....................................................................................iv

1.0 EXECUTIVE SUMMARY

1.1 BACKGROUND

1.2 EXTENT OF CURRENT SURVEY

1.3 ACM MATERIALS FOUND

1.4 OPINIONS AND RECOMMENDATIONS

1.5 LIMITATIONS/DISCLAIMER

2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT

2.1 BACKGROUND

2.2 BUILDING DESCRIPTION

2.3 SAMPLING METHODOLOGY

2.3.1 Asbestos-Containing Materials

2.3.2 Lead-Containing Paint/Lead-Containing Materials

2.4 SAMPLING RESULTS

2.4.1 Asbestos-Containing Materials

2.4.2 Lead-Containing Paint and Building Materials

2.4.3 Toxicity Characteristic Leaching Procedure Sampling

2.4.4 Polychlorinated Biphenyls

2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs

3.0 LIMITATIONS

4.0 STANDARD OF CARE

5.0 CERTIFIED AHERA BUILDING INSPECTORS

APPENDICES

A ........................ Asbestos Laboratory Reports and Field Data Forms

B ........................ Lead Laboratory Reports and Field Data Forms C ........................Certified AHERA Building Inspector Certificates D ........................ Laboratory Certifications for Asbestos and Lead Analysis

E......................... Sample Location Drawings for Asbestos, Lead, and TCLP F......................... Lead TCLP Laboratory Reports and Field Data Forms

G ........................ Abatement Cost Estimate iv

ACRONYM LIST

ACM .......................Asbestos-Containing Material

AHERA ....................Asbestos Hazard Emergency Response Act

AIHA ......................American Industrial Hygiene Association

CFL ........................Compact Fluorescent Light

CFR ........................Code of Federal Regulations

CMU .......................Concrete Masonry Unit

DOSH .....................Washington State Department of Labor and Industries, Division of

Occupational Safety and Health

EA..........................Each

Ecology...................Washington State Department of Ecology

EHSI.......................EHS-International, Inc.

ELLAP .....................Environmental Lead Laboratory Accreditation Program

GWB.......................Gypsum Wall Board

Hg..........................Mercury

HID ........................High Intensity Discharge

JC ..........................Joint Compound

LCM........................Lead-Containing Material

LCP ........................Lead-Containing Paint

LF ..........................Linear Feet

L&I.........................Washington State Department of Labor and Industries mg/cm2...................Milligrams Per Square Centimeter mg/L ......................Milligrams Per Liter

N/A ........................Not Applicable

ND .........................None Detected

NVL ........................NVL Laboratories, Inc.

NVLAP ....................National Voluntary Laboratory Accreditation Program

OD .........................Outside Diameter

OSHA .....................US Occupational Safety and Health Administration

ORCAA....................Olympic Region Clean Air Agency

Pb ..........................Lead

PCBs.......................Polychlorinated Biphenyls

PLM ........................Polarized Light Microscopy ppm .......................Parts per Million

QA .........................Quality Assurance

RCW.......................Revised Code of Washington

SAT ........................Seattle Asbestos Test, LLC

TCLP.......................Toxicity Characteristic Leaching Procedure

VCT ........................Vinyl Composite Tile

WAC.......................Washington Administrative Code

WT .........................Weight w/ ..........................With

XRF ........................x-ray fluorescence

NPS – Lake Quinault - Hopkins Property

EHSI Project 11035

November 17th, 2017

1.0 EXECUTIVE SUMMARY

1.1 BACKGROUND

The National Park Service (NPS) plans to demolish the existing structures on the Hopkins

Property located on Lake Quinault at 606 North Shore Road, Amanda Park, Washington. The

NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Hopkins

Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure (TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl (PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.

1.2 EXTENT OF CURRENT SURVEY

EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:

interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.

1.3 ACM MATERIALS FOUND

SUMMARY OF ASBESTOS-CONTAINING MATERIALS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

ASBESTOS MATERIAL DESCRIPTION LOCATION

Non-ACM gray/brown fibrous material on ACM white caulking

(around smokestack ceiling penetration) [Sample # 23] Kitchen

ACM black window glazing gasket (on 2’x3’6” metal window)

[Sample # 25] Kitchen

Non-ACM silver paint on non-ACM gray/white sealant on ACM black asphaltic tar (on sheet metal roof at seam between high

& low angle roof sections) [Sample # 43]

Exterior Roof

KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, w/ = with

1.4 OPINIONS AND RECOMMENDATIONS

The project includes demolition of the existing structures at the Hopkins Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.

EHSI Project 11035

November 17th, 2017

Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.

Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).

One fluorescent light fixture inspected was found to have a magnetic ballast which is assumed to contain greater than two parts per million (> 2 ppm) PCB-dielectric fluid. The magnetic ballasts must be removed from the fixture and disposed of as Washington Department of

Ecology (Ecology) Dangerous Waste. All fluorescent light tubes contain mercury; any fluorescent tubes to be disturbed during the project must be recycled as (Ecology) Universal

Waste.

1.5 LIMITATIONS/DISCLAIMER

This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. This report and accompanying appendices include the supporting information for this executive summary.

EHSI Project 11035

November 17th, 2017

2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT

2.1 BACKGROUND

The NPS plans to demolish the existing structures at the Hopkins Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:

identification of all suspect materials; a determination of whether suspect materials were:

ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.

On October 12th and 13th, 2017, EHSI conducted a Limited Lead and Asbestos Survey that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of

Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington

Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region

Clean Air Agency (ORCAA).

2.2 BUILDING DESCRIPTION

The Hopkins Property is located on Lake Quinault at 606 North Shore Road, Amanda Park, Washington. Structures on the property include a single-story residential house with loft.

Three exterior storage sheds are attached to the residence by the exterior deck.

The residence is a wood-framed structure with post and pillar foundation on cinderblock footings and wood siding. The roof is constructed of plywood and asphaltic vapor barrier under a sheet metal surface. Interior floor finishes include: Wood laminate and painted plywood.

Interior wall finishes include: wood panels and gypsum wallboard (GWB). Interior ceilings are all plywood. Windows are vinyl or metal-framed and operable. Heating was formerly provided by a wood stove in the residence. No hot water system components were observed on the

Property. Interior lighting consists of incandescent and fluorescent ceiling fixtures and natural light from the windows.

The detached covered structure to the west of the residence consists of wood pillars and siding. A manually operated water well is located to the northeast of the residence.

2.3 SAMPLING METHODOLOGY

2.3.1 Asbestos-Containing Materials

The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of

Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix

C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October

1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.

EHSI Project 11035

November 17th, 2017

EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and

Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary

Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.

Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.

Copies of both laboratories’ NVLAP certifications are included in Appendix D.

2.3.2 Lead-Containing Paint/Lead-Containing Materials

EHSI used an Olympus Delta-Pro x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial

Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program

(ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.

2.4 SAMPLING RESULTS

2.4.1 Asbestos-Containing Materials

Forty-three (43) bulk samples of suspect ACM were collected as part of the survey. Three (3) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The

ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. All suspect materials were accessible for sampling.

EHSI Project 11035

November 17th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

HOPKINS PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-

HOP-01

Kitchen

Hard gray sealant (between gap in laminate wood floor)

ND N/A

11035-

HOP-02

Living

Room

Layer 1: Light gray caulking

(between laminate and plywood)

Layer 2: White leveling compound

Layer 3: Plywood

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-

HOP-03

Living

Room

Layer 1: Brown/white laminate wood flooring

Layer 2: Brown flooring layer

Layer 3: Tan laminate backing

Layer 4: Clear yellow mastic

Layer 5: White levelling compound

(on particle board)

L1: ND

L2: ND

L3: ND

L4: ND

L5: ND

N/A

N/A

N/A

N/A

N/A

11035-

HOP-04

Kitchen

Layer 1: Brown/white laminate wood flooring

Layer 2: Brown flooring layer

Layer 3: Tan laminate backing

Layer 4: Blue foam

Layer 5: Transparent plastic

Layer 6: Brown VCT

Layer 7: Clear mastic (on particle board)

L1: ND

L2: ND

L3: ND

L4: ND

L5: ND

L6: ND

L7: ND

N/A

N/A

N/A

N/A

N/A

N/A

N/A

11035-

HOP-05

Closet

Layer 1: Brown/white laminate wood flooring

Layer 2: Brown flooring layer

Layer 3: Tan laminate backing

Layer 4: Clear blue plastic

Layer 5: Brown vinyl layer

Layer 6: Brown VCT

Layer 7: Clear mastic (on particle board)

L1: ND

L2: ND

L3: ND

L4: ND

L5: ND

L6: ND

N/A

N/A

N/A

N/A

N/A

N/A

11035-

HOP-07

Kitchen

Layer 1: 12” x 12” Green and white ceramic tile (fireplace backdrop and floor)

Layer 2: White grout

Layer 3: Gray mortar

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-

HOP-08

Bedroom

Layer 1: Pink fiberglass batt insulation (in wall)

Layer 2: Black mastic

Layer 3: Brown paper vapor barrier

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-

HOP-09

Living

Room

Layer 1: Yellow fiberglass batt insulation (in wall)

Layer 2: Black mastic

Layer 3: Brown paper vapor barrier

L1: ND

L2: ND

L3: ND

N/A

N/A

EHSI Project 11035

November 17th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

HOPKINS PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-

HOP-10

Living

Room

Layer 1: White JC w/ paint

Layer 2: Yellow mesh joint tape

Layer 3: Green joint tape

Layer 4: GWB wall w/ paper

(corner)

L1: ND

L2: ND

L3: ND

L4: ND

N/A

N/A

N/A

N/A

11035-

HOP-11

Living

Room

White GWB wall w/ paint and paper

(mid-wall)

ND N/A

11035-

HOP-12

Living

Room

White GWB wall w/ paint and paper

(mid-wall)

ND N/A

11035-

HOP-13

Kitchen

Layer 1: Light gray window frame caulking (around 4’6”x3’6” vinyl-framed windows)

Layer 2: Wood wall frame

L1: ND

L2: ND

N/A

N/A

11035-

HOP-

14QA

Living

Room

Clear/beige yellow window frame caulking (on 4’x5’ vinyl-framed windows)

ND N/A

11035-

HOP-15

Living

Room

Layer 1: Black/gray vinyl weather stripping

Layer 2: Trace clear mastic

Layer 3: Gray foam

Layer 4: Black plastic backing

Layer 5: Trace clear mastic

L1: ND

L2: ND

L3: ND

L4: ND

L5: ND

N/A

N/A

N/A

N/A

N/A

11035-

HOP-16

Bedroom

Layer 1: White window frame caulking (around 3’x3’6” vinyl-framed windows)

Layer 2: Wood wall frame

L1: ND

L2: ND

N/A

N/A

11035-

HOP-17

Bedroom

Black window glazing gasket (on

5’x4’ metal-framed window)

ND N/A

11035-

HOP-18

Kitchen

Tan fire brick (from wood burning stove)

ND N/A

11035-

HOP-19

Kitchen

Layer 1: White paper w/ mastic

Layer 2: Black/gray foam weather stripping

Layer 3: Trace clear mastic

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-

HOP-20

Bedroom

Layer 1: Wood walls

Layer 2: Dark brown/brown wood patching compound (wall patch)

L1: ND

L2: ND

N/A

N/A

11035-

HOP-21

Kitchen

Silver/clear sealant (on fireplace smokestack)

ND N/A

11035-

HOP-22

Kitchen

White/gray insulation (inside fireplace smokestack)

ND N/A

EHSI Project 11035

November 17th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

HOPKINS PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

11035-

HOP-23

Kitchen

Layer 1: Gray/brown fibrous material

Layer 2: White caulking

(around smokestack ceiling penetration)

L1: ND

L2: 4%

N/A

Chrysotile

11035-

HOP-24

Kitchen

Layer 1: White/gray paper sink drain gasket

Layer 2: Black rubber gasket

L1: ND

L2: ND

N/A

N/A

11035-

HOP-25

Kitchen

Black window glazing gasket

(on 2’x3’6” metal-framed window)

3% Chrysotile

11035-

HOP-26

Closet

Black plastic electrical panel component (in 1’x2’ electrical panel)

ND N/A

11035-

HOP-28

Kitchen

Layer 1: White plastic cabinet cover

Layer 2: Trace clear mastic

Layer 3: Wood cabinet

L1: ND

L2: ND

L3: ND

N/A

N/A

N/A

11035-

HOP-29

Kitchen

Beige mastic (under cement countertops)

ND N/A

11035-

HOP-30

Loft

Blue/green/brown coating/sealant

(on seams of plywood roof decking)

ND N/A

EXTERIOR AND ROOF

11035-

HOP-32

Roof over

Deck

Black asphaltic vapor barrier (under sheet metal roofing)

ND N/A

11035-

HOP-

33QA

Roof over

House

Black asphaltic vapor barrier (under sheet metal roofing)

ND N/A

11035-

HOP-34

Exterior Gray CMU block ND N/A

11035-

HOP-35

Exterior

White window glazing gasket (on

4’x3’ vinyl-framed windows)

ND N/A

11035-

HOP-36

Exterior

Closet

Gray window glazing gasket (on

3’x2’ metal-framed windows)

ND N/A

11035-

HOP-37

Exterior

White window frame caulking (on

2’x2’6” vinyl-framed window)

ND N/A

11035-

HOP-38

Exterior

Light gray rubbery window screen gasket (w/ metal frame on 2’x3’6” vinyl-framed window)

ND N/A

11035-

HOP-43

Exterior

Roof at seam between roof sections

Layer 1: Silver paint

Layer 2: Gray/white sealant

Layer 3: Black asphaltic tar (on sheet metal roofing at seam between high & low angle roof sections)

L1: ND

L2: ND

L3: 3%

N/A

Chrysotile

EHSI Project 11035

November 17th, 2017

TABLE 1

SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

HOPKINS PROPERTY

SAMPLE

NUMBER

SAMPLE

LOCATION

MATERIAL DESCRIPTION

ASBESTOS

TYPE OF

ASBESTOS

EXTERIOR SHED AND WATER WELL

11035-

HOP-06

Storage

Shed

Layer 1: Black rubber mat

Layer 2: White woven mesh

Layer 3: Black rubber mat

Layer 4: White woven mesh

Layer 5: Black rubber mat

Layer 6: White woven mesh

Layer 7: Black rubber mat

(mechanically fastened to wood)

L1: ND

L2: ND

L3: ND

L4: ND

L5: ND

L6: ND

L7: ND

N/A

N/A

N/A

N/A

N/A

N/A

N/A

11035-

HOP-27

Water well

4” OD black rubber gasket (on well pump)

ND N/A

11035-

HOP-31

Storage

Shed Silver paint roof sealant (in bucket) ND N/A

11035-

HOP-39

Storage

Shed

Light gray rubbery window glazing gasket (on 1’x1’ metal-framed window)

ND N/A

11035-

HOP-40

Storage

Shed

Black rubber window screen gasket

(w/ metal frame on 2’x3’6” vinyl-framed window)

ND N/A

11035-

HOP-

41QA

Detached

Outdoor

Covered

Area

Gray sealant (on black rubber mat roof)

ND N/A

11035-

HOP-42

Water well

Layer 1: White sealant (on 3” OD metal pipe)

Layer 2: Wood

L1: ND

L2: ND

N/A

N/A KEY: bold = bold text indicates asbestos-containing layer, CMU = concrete masonry unit, GWB = gypsum wall board, JC = joint compound, ND = non-detect, N/A = not applicable, OD = outer diameter, VCT = vinyl composite tile, w/ = with

Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2

Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.

TABLE 2

SUMMARY OF ASBESTOS-CONTAINING MATERIALS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY

Non-ACM gray/brown fibrous material on ACM white caulking (around smokestack ceiling penetration)

[Sample # 23]

Kitchen 3 LF

EHSI Project 11035

November 17th, 2017

TABLE 2

SUMMARY OF ASBESTOS-CONTAINING MATERIALS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY

ACM black window glazing gasket (on 2’x3’6” and

3’x2’ metal-framed windows) [Sample # 25] Kitchen 3 EA

Non-ACM silver paint on non-ACM gray/white sealant on

ACM black asphaltic tar (on sheet metal roof at seam between high & low angle roof sections) [Sample # 43]

Exterior Roof 160 LF

KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, EA = each, LF = linear feet, w/ = with

ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential for concealed suspect ACM and have pre-planned contingencies for the handling of suspect

ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building

Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.

2.4.2 Lead-Containing Paint and Building Materials

Thirty-five (35) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer.

XRF paint sample results ranged from greater than or equal to 5.0 milligrams of lead per square centimeter (mg Pb/cm2) to <LOD. Bolded results indicate materials coated with

“lead-based paint” (e.g., >1.0 mg/cm2) as defined by USEPA regulation 40CFR745 and Washington State Commerce regulation WAC 365-230. The results are provided in

Table 3 of this report.

Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.

TABLE 3

XRF SAMPLING

SUMMARY OF PAINTED COMPONENTS AND MATERIALS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

Read

Component Substrate Color Building Room

Lead

Conc.

(mg/cm2)

1 NIST Check N/A Red Hopkins Property Calibration 1.2

2 NIST Check N/A Red Hopkins Property Calibration 1.11

3 NIST Check N/A Red Hopkins Property Calibration 1.17

EHSI Project 11035

November 17th, 2017

TABLE 3

XRF SAMPLING

SUMMARY OF PAINTED COMPONENTS AND MATERIALS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

4 Wall Drywall Blue Hopkins Property Livingroom < LOD

5 Floor Wood Beige Hopkins Property Livingroom < LOD

6 Window Frame Plastic White Hopkins Property Livingroom < LOD

7 Floor Fiber Board Light Brown Hopkins Property Kitchen < LOD

8 Fireplace Mantle Metal Black Hopkins Property Kitchen 0.02

9 Fireplace Mantle Ceramic Off White Hopkins Property Kitchen 0.01

10 Fireplace Mantle Ceramic Off White Hopkins Property Kitchen 0.01

11 Fireplace Mantle Ceramic Blue Hopkins Property Kitchen < LOD

12 Fireplace Mantle Metal Black Hopkins Property Kitchen 0.01

13 Wall Trim Metal Black Hopkins Property Kitchen < LOD

14 Counter Concrete Dark Gray Hopkins Property Kitchen < LOD

15 Sink Metal Silver Hopkins Property Kitchen < LOD

16 Cabinet Wood Blue Hopkins Property Kitchen < LOD

17 Window Frame Metal Brown Hopkins Property Master

Bedroom

< LOD

18 Window Frame Plastic White Hopkins Property Master

Bedroom

< LOD

19 Door Metal White Hopkins Property Livingroom < LOD

20 Door Metal Green Hopkins Property Livingroom < LOD

21 Door Metal Beige Hopkins Property Livingroom < LOD

22 Door Frame Wood White Hopkins Property Exterior < LOD

23 Roof Flashing Metal Dark Green Hopkins Property Exterior 0.07

24 Roof Metal Dark Green Hopkins Property Exterior < LOD

25 Window Frame Metal Brown Hopkins Property Exterior 0.01

26 Door Trim Metal Dark Green Hopkins Property Exterior 0.01

27 Gutter Metal Dark Green Hopkins Property Exterior < LOD

28 Wall Wood Brown Hopkins Property Exterior < LOD

29 Fume Hood Metal Dark Green Hopkins Property Exterior 0.14

30 Electrical Box Metal Gray Hopkins Property Exterior < LOD

31 Wall Drywall Light Blue Hopkins Property Livingroom < LOD

32 NIST Check N/A Red Hopkins Property Livingroom 1.22

33 NIST Check N/A Red Hopkins Property Livingroom 1.29

34 NIST Check N/A Red Hopkins Property Livingroom 1.14

35 NIST Check N/A Red Hopkins Property Livingroom 1.25

57 Wall Wood Light Blue Storage Sheds Outbuilding 1

Ext 0.24

58 Wall Wood Red Storage Sheds Outbuilding 1

Ext 0.26

EHSI Project 11035

November 17th, 2017

TABLE 3

XRF SAMPLING

SUMMARY OF PAINTED COMPONENTS AND MATERIALS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

59 Door Trim Wood White Storage Sheds Outbuilding 1

Ext

< LOD

60 Door Trim Wood Light Gray Storage Sheds Outbuilding 1

Ext

< LOD

61 Floor Concrete Light Gray Storage Sheds Outbuilding 2

Ext

< LOD

62 Wall Metal Light Blue Storage Sheds Outbuilding 2

Ext 0.01

63 Wall Trim Metal White Storage Sheds Outbuilding 2

Ext 0.01

64 NIST Check Drywall Red N/A N/A 1.07

65 NIST Check Drywall Red N/A N/A 1.08

66 NIST Check Drywall Red N/A N/A 1.01

67 NIST Check Drywall Red N/A N/A 1.1

In addition to the XRF samples, EHSI collected two (2) bulk QA samples for laboratory analysis. The bulk sample results were both less than the reporting limit. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations.

Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.

Copies of the analytical laboratory report and field data forms for lead paint are included in

Appendix B of this report.

TABLE 4

SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

SAMPLE

NUMBER

LOCATION

COMPONENT/

SUBSTRATE

COLOR

RESULTS

% Pb by

WT

11035-HOP-

Pb01 House, Kitchen Fireplace

Ceramic tile with mortar and grout Green <0.0026

11035-HOP-

Pb02 House, Exterior Foundation CMU Gray <0.0036

Key: CMU = concrete masonry unit, Pb = lead, WT = weight

DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.

Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to

EHSI Project 11035

November 17th, 2017 determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.

2.4.3 Toxicity Characteristic Leaching Procedure Sampling

Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).

At the request of NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos

Survey. The results of that lead-TCLP analysis indicate no leachable lead was present in the anticipated demolition waste stream above the laboratories reporting limit at a concentration of <0.5 mg/L. A detailed list of the materials included in the TCLP sample are provided in

Appendix F.

It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.

2.4.4 Polychlorinated Biphenyls

Ballasts

EHSI inspected each type of fluorescent fixture for PCB-containing ballasts. One fixture inspected was found to contain a magnetic ballast and must be assumed to contain PCB containing dialectic fluid; therefore, it must be disposed/recycled as Ecology Dangerous

Waste. A Summary of ballasts and Hg-containing light tubes is provided in Table 5.

2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs

All fluorescent light tubes quantified in Table 5 contain Hg. Hg wastes are regulated as

“universal wastes” under Ecology’s regulation WAC 173-303. Hg-containing building materials must be recycled or disposed of as hazardous waste.

TABLE 5

SUMMARY OF LIGHT FIXTURE INSPECTION RESULTS

NATIONAL PARK SERVICE

LAKE QUINAULT – HOPKINS PROPERTY

LIGHT TYPE FIXTURES

TUBES/

BULBS

MAGNETIC

BALLASTS

4’x 1’ Suspended light fixture w/ 2 bulbs and

1 magnetic ballast 1 2 1

Total Hopkins Property 1 2 1

EHSI Project 11035

November 17th, 2017

3.0 LIMITATIONS

This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished. All suspect materials present were accessible for sampling.

This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be

ACM by this survey report when encountered must be treated as ACM until sampled by a

Certified AHERA Building Inspector and analyzed by a certified laboratory.

4.0 STANDARD OF CARE

The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.

5.0 CERTIFIED AHERA BUILDING INSPECTORS

The Certified AHERA Building Inspectors listed below surveyed on October 12th and 13th, 2017, in accordance with federal, state, and local requirements.

Tim Nickell Mike Ruark

Certified AHERA Building Inspector Certified AHERA Building Inspector

Certificate Number: 1628878 Certificate Number: 163007

Expiration Date: August 10, 2018 Expiration Date: September 6, 2018

Appendix A

APPENDIX A

Asbestos Analytical Laboratory Report and Field Data Forms

Lori Tseng, Laboratory Analyst

Client Project: 11035-02

Location: Hopkins Property

Dear Mr. Peterson, Enclosed please find test results for the 3 sample(s) submitted to our laboratory for analysis on

10/18/2017.

Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116

Method for the Determination of Asbestos in Bulk Building Materials.

For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.

For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.

The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%

Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.

Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.

Sincerely, Enc.: Sample Results

October 25, 2017

Lori T Labo to A lyst

Rory Peterson

EHS International

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1718555.00

< Client:

Address:

Attention: Mr. Rory Peterson

Hopkins Property

Client Project #: 11035-02

Samples Received: 3

By Polarized Light Microscopy

Bulk Asbestos Fibers Analysis

EHS International

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Method: EPA/600/R-93/116

& EPA/600/M4-82-020

Samples Analyzed: 3

Project Location:

Batch #: 1718555.00

Date Received: 10/18/2017

17101330Lab ID: Client Sample #:

Location: Hopkins Property

11035-HOP-14QA

Layer 1 of 1 Description: Beige soft elastic material (on wood)

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Caulking compound <1%Cellulose None Detected ND

17101331Lab ID: Client Sample #:

Location: Hopkins Property

11035-HOP-33QA

Layer 1 of 1 Description: Black asphaltic fibrous felt

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Asphalt/Binder, Binder/Filler, Fine particles 67%Cellulose None Detected ND

2%Spider silk

17101332Lab ID: Client Sample #:

Location: Hopkins Property

11035-HOP-41QA

Layer 1 of 1 Description: Gray soft material

Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %

Binder/Filler, Fine particles NDNone Detected None Detected ND

Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA

600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL

Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government

Client

Welly HsiehAnalyzed by:

Lori TsengReviewed by:

10/24/2017 Date:

10/25/2017Date:

Sampled by:

Lori Tseng, Laboratory Analyst

EHS International 1718555.00

Company NVL Batch Number

Total Number of Samples

Hopkins Property

5 DaysTAT

10/25/2017Due Date 9:40 AMTime

(206) 254-4279Fax roryp@ehsintl.comEmail

Project Manager Mr. Rory Peterson

(206) 381-1128

(425) 766-8342Cell

Phone

Rush Samples

Rush TAT

NoAH

11035-02Project Name/Number: Project Location:

Sample ID Description A/RLab ID

ASBESTOS LABORATORY SERVICES

Subcategory

Item Code

PLM Bulk

Metals

ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Address

11035-HOP-14QA1 A17101330

11035-HOP-33QA2 A17101331

11035-HOP-41QA3 A17101332

Office Use Only Print Name Company Date TimeSignature

Faxed Emailed

Company Date TimeSignature

ClientSampled by

Umer KhanReceived by

ClientRelinquished by

Welly HsiehAnalyzed by

Results Called by

NVL

NVL

10/18/17

10/24/17

Print Name

Entered By: Soumeya Benzina

Date: 10/18/2017

Time: 1:18 PM

Special

Instructions:

Appendix B

APPENDIX B

Lead Laboratory Reports and Field Data Forms

RE: Metals Analysis; NVL Batch # 1718536.00

Dear Mr. Peterson, October 19, 2017

EHS International

Rory Peterson

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Enclosed please find the test results for samples submitted to our laboratory for analysis.

Preparation of these samples was conducted following protocol outlined in EPA Method SW 846

-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.

For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.

For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.

This report is considered highly confidential and will not be released without your approval.

Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.

Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.

Sincerely, Nick Ly, Technical Director

Analysis Report Total Lead (Pb)

Hopkins Property

EHS InternationalClient:

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Mr. Rory PetersonAttention:

Address:

Project Location: Samples Received: 2

Samples Analyzed: 2

Client Project #: 11035-02

Batch #: 1718536.00

Date Received: 10/18/2017

Lab ID Client Sample #

Sample

Weight (g)

Results in mg/Kg

Results in percent

RL in mg/Kg

Matrix: Bulk

Method: EPA 3051/7000B

17101213 11035-HOP-Pb01 0.3834 26 < 26 0.0026<

17101214 11035-HOP-Pb02 0.2760 36 < 36 0.0036<

ClientSampled by:

Yasuyuki HidaAnalyzed by:

Nick LyReviewed by:

10/19/2017Date Analyzed:

10/19/2017Date Issued:

Bench Run No: 2017-1019-5 mg/ Kg =Milligrams per kilogram RL = Reporting Limit

Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit Note : Method QC results are acceptable unless stated otherwise.

Unless otherwise indicated, the condition of all samples was acceptable at time of receipt.

EHS International 1718536.00

Company NVL Batch Number

Total Number of Samples

Hopkins Property

5 DaysTAT

10/25/2017Due Date 9:40 AMTime

(206) 254-4279Fax roryp@ehsintl.comEmail

Project Manager Mr. Rory Peterson

(206) 381-1128

(425) 766-8342Cell

Phone

Rush Samples

Rush TAT

NoAH

11035-02Project Name/Number: Project Location:

Sample ID Description A/RLab ID

LEAD LABORATORY SERVICES

Subcategory

Item Code

Flame AA (FAA)

Metals

FAA-02 EPA 7000B Lead by FAA <paint>

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Address

11035-HOP-Pb011 A17101213

11035-HOP-Pb022 A17101214

Office Use Only Print Name Company Date TimeSignature

Faxed Emailed

Company Date TimeSignature

ClientSampled by

Umer KhanReceived by

ClientRelinquished by

Yasuyuki HidaAnalyzed by

Results Called by

NVL

NVL

10/18/17

10/19/17

Print Name

Entered By: Mohammed Jamal

Date: 10/18/2017

Time: 11:31 AM

Special

Appendix C

APPENDIX C

Certified AHERA Building Inspector Certificates

Appendix D

APPENDIX D

Laboratory Certifications for Asbestos and

Lead Analysis

AIHA Laboratory Accreditation Programs, LLC acknowledges that

NVL Laboratories, Inc.

4708 Aurora Avenue N., Seattle, WA 98103

Laboratory ID: 101861 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation

Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:

LABORATORY ACCREDITATION PROGRAMS

INDUSTRIAL HYGIENE Accreditation Expires: June 01, 2019

ENVIRONMENTAL LEAD Accreditation Expires: June 01, 2019

ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: June 01, 2019

FOOD Accreditation Expires:

UNIQUE SCOPES Accreditation Expires: June 01, 2019

Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC

17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA-

LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.

William Walsh, CIH

Chairperson, Analytical Accreditation Board

Cheryl O. Morton

Managing Director, AIHA Laboratory Accreditation Programs, LLC

Revision 15: 03/30/2016 Date Issued: 05/31/2017

Effective: 04/10/2015

101861_Scope_IHLAP_2017_05_31

AIHA Laboratory Accreditation Programs, LLC

SCOPE OF ACCREDITATION

NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017

The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

Industrial Hygiene Laboratory Accreditation Program (IHLAP)

Initial Accreditation Date: 04/01/1997

IHLAP Scope

Category

Field of Testing (FoT)

(FoTs cover all relevant

IH matrices)

Technology sub-type/

Detector

Published Reference

Method/Title of In-house Method

Method Description or Analyte (for internal methods only)

Spectrometry Core

Inductively-Coupled

Plasma

ICP/AES

EPA 3051

NIOSH 7300 Modified

X-ray Diffraction (XRD) NIOSH 7500

Asbestos/Fiber

Microscopy Core

Phase Contrast

Microscopy (PCM)

NIOSH 7400

Miscellaneous Core Gravimetric NIOSH 0500 Modified

NIOSH 0600 Modified

A complete listing of currently accredited Industrial Hygiene laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org

Effective: 10/14/2016

Scope_ELLAP_R7

AIHA Laboratory Accreditation Programs, LLC

SCOPE OF ACCREDITATION

NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017

The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

The EPA recognizes the AIHA-LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory

Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air and composited wipes analyses are not included as part of the NLLAP.

Environmental Lead Laboratory Accreditation Program (ELLAP)

Initial Accreditation Date: 02/07/1997

A complete listing of currently accredited Environmental Lead laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org

Field of Testing (FoT) Technology sub-type/

Detector Method

Method Description (for internal methods only)

Paint

EPA SW-846 3051

EPA SW-846 7000B

Soil

EPA SW-846 3051

EPA SW-846 7000B

Settled Dust by Wipe

EPA SW-846 3051

EPA SW-846 7000B

Airborne Dust

EPA SW-846 3051

NIOSH 7082

Effective: 03/12/2013

101861_Scope_EMLAP_2017_05_31

AIHA Laboratory Accreditation Programs, LLC

SCOPE OF ACCREDITATION

NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017

The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

Environmental Microbiology Laboratory Accreditation Program (EMLAP)

Initial Accreditation Date: 02/01/1997

EMLAP Category Field of Testing

(FoT) Method Method Description

(for internal methods only)

Fungal

Air - Direct

Examination SOP 12.133 In-House: Analysis of Spore Trap

Bulk - Direct

Examination SOP 12.133 In-House: Bulk Analysis

Surface - Direct

Examination SOP 12.133 In-House: Surface Analysis

A complete listing of currently accredited Environmental Microbiology laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org

Effective: 08/29/2014

Scope_UniqueScopes_R1

AIHA Laboratory Accreditation Programs, LLC

SCOPE OF ACCREDITATION

NVL Laboratories, Inc. Laboratory ID: 101861 4708 Aurora Avenue N., Seattle, WA 98103 Issue Date: 05/31/2017

The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

Unique Scopes Laboratory Accreditation Program (Unique Scopes)

Initial Accreditation Date: 04/01/2013

A complete listing of currently accredited Unique Scope laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org

Unique Scope Category Field of Testing (FoT) Method Method Description

(for internal methods only)

Consumer Product Testing

Lead in Paint and Other

Similar Surface Coatings

CPSC-CH-E1003-09.1

Total Lead in Metal

Children’s Products

CPSC-CH-E1001-08.2

Total Lead in Non-Metal

Children’s Products

CPSC-CH-E1002-08.1

Appendix E

APPENDIX E

Sample Location Drawings for Asbestos, Lead, and TCLP

KITCHEN LIVING ROOMBEDROOM

DECK CLOSET

DECK

DECK

STORAGE

WELL

DECK

DECK

COVERED AREA

SHED

SL-1

HOPKINS

HOUSE

PROJECT NORTH

HOPKINS HOUSE

NOT TO SCALE

EHSI PROJECT #:

SCALE:

SURVEY DATES:

DRAWN BY:

INSPECTORS:

PROJECT MANAGER:

ISSUE DATE:

H O

P K

IN

S

P R

O P

E R

TY

N

O R

TH

S

H O

R E

R D

Q U

IN

A

U

LT

, W A

U S

D E

P A

R

TM

E N

T O

F

TH

E

IN

TE

R

IO

R

N P

S P

O R

T A

N G

E

LE

S , W

A

GENERAL NOTES

1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE

APPROXIMATE.

2. REFER TO REPORT FOR MORE INFORMATION ABOUT

THE SAMPLED MATERIALS.

1011 SW Klickitat Way, Suite 104

Seattle, Washington 98134

Ph: 206.381.1128

Fax: 206.254.4279

EHS-International, Inc.

SAMPLE LEGEND

BULK ASBESTOS SAMPLE LOCATIONS11035-HOP-XX

P R

O

JE

C T

P R

O P

E R

T Y

I D

S A

M P

L E

# PROPERTY ID:

HOP = HOPKINS PROPERTY

BULK LEAD SAMPLE LOCATIONS11035-HOP-PbXX

BULK TCLP SUB-SAMPLE11035-HOP-TCLP-XXA

11035-HOP-39

11035-HOP-05

11035-HOP-38

11035-HOP-24

11035-HOP-29

11035-HOP-37

11035-HOP-09

11035-HOP-10

11035-HOP-01

11035-HOP-34

11035-HOP-15

11035-HOP-14

11035-HOP-33

11035-HOP-32

11035-HOP-41

11035-HOP-26

11035-HOP-36

11035-HOP-31

11035-HOP-06

11035-HOP-27

11035-HOP-17

11035-HOP-20

11035-HOP-08

11035-HOP-16

11035-HOP-18

11035-HOP-07

11035-HOP-13

11035-HOP-25

11035-HOP-19

11035-HOP-43

11035-HOP-28

11035-HOP-42

11035-HOP-40

11035-HOP-12

11035-HOP-35

11035-HOP-Pb02

11035-HOP-02

11035-HOP-03

11035-HOP-04

11035-HOP-Pb01

11035-HOP-21

11035-HOP-22

11035-HOP-23

11035-HOP-TCLP-01A

11035-HOP-TCLP-01I

11035-HOP-TCLP-X

11035-HOP-TCLP-01L

11035-HOP-TCLP-01C

11035-HOP-TCLP-01G

11035-HOP-TCLP-01J

11035-HOP-TCLP-01K

11035-HOP-TCLP-01B

11035-HOP-TCLP-01D

11035-HOP-TCLP-01F

11035-HOP-TCLP-01E

Appendix F

APPENDIX F

Lead TCLP Laboratory Reports and Field Data Forms

RE: Metals Analysis; NVL Batch # 1718518.00

Dear Mr. Peterson, October 25, 2017

EHS International

Rory Peterson

1011 SW Klickitat Way. Suite 104

Seattle, WA 98134

Enclosed please find the test results for samples submitted to our laboratory for analysis.

Preparation of these samples was conducted following protocol outlined in EPA Method SW 846

-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.

For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.

For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.