LIMITED LEAD AND ASBESTOS SURVEY REPORT
NATIONAL PARKS SERVICE – OLYMPIC NATIONAL PARK
LAKE OZETTE - KLEIVA PROPERTY
East Shore of Lake Ozette
Forks, Washington 98331
November 10th, 2017
Prepared For:
Jeff Doryland
Deputy Chief of Facility Management
Olympic National Park
600 E. Park Avenue, Port Angeles, WA 98273 ii
Limited Lead and Asbestos Survey Report
National Park Service – Olympic National Park
Lake Ozette - Kleiva Property
East Shore of Lake Ozette
Forks, Washington
EHSI Project No.: # 11035
The material and data in this report were prepared under the supervision and direction of the undersigned.
Brett Racine
Lead AHERA Building Inspector
Derica Escamilla
Principal of Hazardous Materials
Services iii
TABLE OF CONTENTS
Acronym List .................................................................................... iv
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
1.2 EXTENT OF CURRENT SURVEY
1.3 ACM MATERIALS FOUND
1.4 OPINIONS AND RECOMMENDATIONS
1.5 LIMITATIONS/DISCLAIMER
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
2.2 BUILDING DESCRIPTION
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
2.3.2 Lead-Containing Paint/Lead-Containing Materials
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
2.4.2 Lead-Containing Paint and Building Materials
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
2.4.4 Polychlorinated Biphenyls
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
3.0 LIMITATIONS
4.0 STANDARD OF CARE
5.0 CERTIFIED AHERA BUILDING INSPECTORS
APPENDICES
A........................ Asbestos Laboratory Reports and Field Data Forms
B........................ Lead Laboratory Reports and Field Data Forms
C........................ Certified AHERA Building Inspector Certificates
D ....................... Laboratory Certifications for Asbestos and Lead Analysis
E ........................ Sample Location Drawings for Asbestos, Lead, and TCLP
F ........................ Lead TCLP Laboratory Reports and Field Data Forms
G ....................... Abatement Cost Estimate iv
ACRONYM LIST
ACM.......................Asbestos-Containing Material
AHERA ................... Asbestos Hazard Emergency Response Act AIHA ...................... American Industrial Hygiene Association
CFL ........................ Compact Fluorescent Light CFR ....................... Code of Federal Regulations
DOSH.....................Washington State Department of Labor and Industries, Division of
Occupational Safety and Health Ecology .................. Washington State Department of Ecology
EHSI ...................... EHS-International, Inc.
ELLAP .....................Environmental Lead Laboratory Accreditation Program
GWB ...................... Gypsum Wall Board Hg ......................... Mercury
HID........................High Intensity Discharge LCM ....................... Lead-Containing Material
LCP........................Lead-Containing Paint
L&I ........................ Washington State Department of Labor and Industries mg/cm2 .................. Milligrams Per Square Centimeters mg/L......................Milligrams Per Liter N/A ........................Not Applicable
ND.........................None Detected NVL ....................... NVL Laboratories, Inc.
NVLAP .................... National Voluntary Laboratory Accreditation Program OD.........................Outside Diameter
ORCAA ................... Olympic Region Clean Air Agency
OSB ....................... Orient Strand Board OSHA ..................... US Occupational Safety and Health Administration
Pb ......................... Lead PCBs ...................... Polychlorinated Biphenyls
PLM ....................... Polarized Light Microscopy ppm.......................Parts per Million
QA ......................... Quality Assurance RCW ...................... Revised Code of Washington
SAT ....................... Seattle Asbestos Test, LLC
SF ......................... Square Feet SVF........................Sheet Vinyl Flooring
TCLP ...................... Toxicity Characteristic Leaching Procedure WAC ...................... Washington Administrative Code
WT ........................ Weight w/ ......................... With
XRF ....................... x-ray fluorescence
NPS – Lake Ozette - Kleiva Property
EHSI Project 11035 November 10th, 2017
1.0 EXECUTIVE SUMMARY
1.1 BACKGROUND
The National Parks Service (NPS) plans to demolish the existing structures on the Kleiva
Property located on the East Shore of Lake Ozette, Forks, Washington. The NPS has contracted EHS-International, Inc. (EHSI), a hazardous materials and industrial hygiene consulting firm, to conduct a Limited Lead and Asbestos Survey of the Kleiva Property in preparation for this project. The intent of the survey is to specifically identify and quantify asbestos-containing building materials (ACM), lead-containing paint (LCP), other lead-containing building materials (LCM), to collect a lead toxicity characteristic leaching procedure (TCLP) sample representative of all materials that may be in the assumed waste stream, and to inspect and quantify fluorescent light fixtures that may contain polychlorinated biphenyl (PCB)-containing ballasts, and mercury (Hg)-containing fluorescent light tubes, compact fluorescent light (CFL) bulbs, and high intensity discharge (HID) lamps, that may be impacted by the demolition.
1.2 EXTENT OF CURRENT SURVEY
EHSI inspected all accessible interior and exterior materials potentially impacted by the proposed project. Accessible suspect materials were sampled including, but not limited to:
interior and exterior wall systems, window systems, and mechanical systems. EHSI accomplished a representative destructive inspection.
1.3 ACM MATERIALS FOUND
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARKS SERVICE
OZETTE LAKE – KLEIVA PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION
Non-ACM Beige and brown SVF (w/ large broken rock pattern) w/ ACM gray paper backing w/ ACM tan mastic on wood [Sample # 01]
Bedroom 1
Non-ACM SVF (w/ geometric pattern) w/ ACM gray paper backing w/
ACM tan mastic on OSB on non-ACM black mastic on wood [Sample # 08]
Kitchen/ Living room
KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, OSB = oriented strand board, SVF = sheet vinyl flooring w/ = with
1.4 OPINIONS AND RECOMMENDATIONS
The project includes demolition of the existing structures at the Kleiva Property; therefore, EHSI recommends that all impacted ACM identified in paragraph 1.3 be removed and disposed of prior to renovation and demolition activities.
Any suspect materials not identified as having been surveyed in this report must be treated as an ACM until determined otherwise by a Certified Asbestos Building Inspector and NVLAP certified laboratory.
EHSI Project 11035 November 10th, 2017
Washington State Department of Labor and Industries (L&I) Division of Occupational Safety and Health (DOSH) and the US Occupational Safety and Health Administration (OSHA) require employers to conduct a hazard assessment and take appropriate worker protection precautions whenever building materials are disturbed that have detectable quantities of lead. Since the type of work planned (e.g., demolition) will disturb the LCP, the contractor should perform an initial exposure assessment to determine if the additional personal protective measures and work practices are required beyond that of initial assessment. Special care should be taken to reduce potential employee exposure to lead when demolishing porcelain bathroom fixtures and painted metal, including reducing airborne dust (eq., water misting and use of hand tools, and/or local exhaust ventilation).
EHSI did not observe any mercury-containing fluorescent light tubes, CFL bulbs, or HID lamps on the Kleiva property.
1.5 LIMITATIONS/DISCLAIMER
This report does not represent a comprehensive hazardous materials investigation for the subject property. This investigation has been conducted by EHSI under a specific scope of work authorized by the NPS for a specific purpose. This report and accompanying appendices include the supporting information for this executive summary.
EHSI Project 11035 November 10th, 2017
2.0 LIMITED LEAD AND ASBESTOS SURVEY REPORT
2.1 BACKGROUND
The NPS plans to demolish the existing structures at the Kleiva Property. In conjunction with the planned demolition, the NPS has contracted EHSI to accomplish a pre-demolition limited lead and asbestos survey of the existing structures and to collect a lead-TCLP sample representative of the anticipated demolition debris. For the limited lead and asbestos survey, EHSI was tasked to use applicable federal, state, and local guidelines in the accomplishment of its survey. EHSI was further tasked to provide a written survey report including:
identification of all suspect materials; a determination of whether suspect materials were:
ACM, LCP, and LCM, and to provide analytical reports indicating the presence and quantity of the hazardous materials.
On October 4th, 2017, EHSI conducted a Limited Lead and Asbestos Survey Report that meets the Washington State “Good Faith Survey” requirements as cited in Revised Code of
Washington (RCW) 49.26.016 and implemented by L&I DOSH regulation, Washington Administrative Code (WAC) 296-62-07721, and Regulation Section 570 of the Olympic Region
Clean Air Agency (ORCAA).
2.2 BUILDING DESCRIPTION
The Kleiva Property is located on the East Shore of Lake Ozette, Forks, Washington. The property includes a single-story single occupancy residential house.
The house is a wood-framed structure with a post and pier foundation. The building has a partially collapsed wood shingle roof and a wood siding exterior. The entire south facing exterior wall has also collapsed, destroying most of what was once bedroom 2 and the kitchen area of the living room. Remaining and remnant interior floor finishes include: sheet vinyl flooring (SVF), carpet, and possibly ceramic tile. Remaining and remnant interior wall finishes include: wood fiberboard panels and possibly GWB. The interior ceilings were finished with wood paneling. Windows are aluminum-framed; most but not all remaining windows are operable. Hot water was provided by a domestic hot water tank. Heating appears to have been provided by the wood stove fireplace. Interior lighting consists of incandescent ceiling fixtures and natural light from the windows.
2.3 SAMPLING METHODOLOGY
2.3.1 Asbestos-Containing Materials
The EHSI field inspectors are asbestos Building Inspectors, certified under the requirements of the United States Environmental Protection Agency (USEPA) AHERA regulation 40 Code of
Federal Regulations (CFR) 763, Subpart E. Copies of their certificates are provided in Appendix C. The number of bulk samples collected and their locations are based on the AHERA regulation and the guidelines provided by the USEPA Document 560/5-85-030a, October
1985, Asbestos in Buildings: Simplified Sampling Scheme for Friable Surfacing Materials.
EHSI Project 11035 November 10th, 2017
EHSI collected samples and obtained analytical data for suspect ACM identified on the property. Once collected, each bulk sample was sealed in an unadulterated plastic bag to eliminate the possibility of cross-contamination. “Chain-of-Custody” tracking was followed to maintain sample integrity during handling and data reporting at EHSI and the analytical laboratory. As specified in 40 CFR Chapter 1 (1-1-87 edition) Part 763, Subpart F, and Appendix A, each sample was analyzed using polarized light microscopy (PLM) / dispersion staining techniques, in accordance with USEPA Method 600/R-93/116. Samples were analyzed for asbestos content by Seattle Asbestos Test, LLC (SAT) located in Seattle, Washington. SAT participates in the National Institute for Standards and Technology (NIST) National Voluntary Laboratory Accreditation Plan (NVLAP). Only materials containing more than 1% total asbestos were classified as “asbestos-containing” based on USEPA, state, and local regulations.
Samples in the report labeled as ##QA are quality assurance (QA) samples. Split samples were taken from the same location and they were sent to separate laboratories. QA samples were submitted to, NVL Laboratories, Inc. (NVL) in Seattle, WA, another NVLAP laboratory.
Copies of both laboratories’ NVLAP certifications are included in Appendix D.
2.3.2 Lead-Containing Paint/Lead-Containing Materials
EHSI used an Olympus Delta-Pro x-ray fluorescence (XRF) Spectrum Analyzer to measure lead content on interior and exterior paint coatings and other suspect LCM. Measurements were representative of all layers of paint and/or LCM. A summary of Lead Paint XRF results is provided in Table 3. Bulk quality assurance samples were taken for a representative number of LBP and LCM and were sent to NVL located in Seattle, Washington, an accredited laboratory for Atomic Absorption Spectroscopy (USEPA Method-7000B) by the American Industrial Hygiene Association (AIHA) under the Environmental Lead Laboratory Accreditation Program
(ELLAP). Copies of laboratory reports and field data forms for lead are in Appendix B.
2.4 SAMPLING RESULTS
2.4.1 Asbestos-Containing Materials
Twenty-two (22) bulk samples of suspect ACM were collected as part of the survey. Two (2) of those samples were split for quality assurance analyses. Limited destructive inspection was conducted to identify hidden and/or concealed materials. Copies of the asbestos analytical laboratory results are included in Appendix A. Asbestos and lead sample location drawings are provided in Appendix E. Asbestos sampling information including: sample number, material description, sample location, and analytical results are summarized in Table 1. The ACM and assumed ACM identified during this survey, including the quantity and location, is summarized in Table 2. All suspect materials were accessible for sampling.
EHSI Project 11035 November 10th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARKS SERVICE
LAKE OZETTE – KLEIVA PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-
KLE-01
Bedroom
Layer 1: Beige and brown SVF (w/ large broken rock pattern)
Layer 2: Gray paper backing w/ tan mastic
Layer 3: Wood
L1: ND
L2: 53%
L3: ND
N/A
Chrysotile
N/A
11035-KLE-
Bedroom 1
Layer 1: Pink fiberglass batt insulation
Layer 2: Black paper/mastic
L1: ND
L2: ND
N/A
N/A
11035-KLE-
Bedroom 1
Layer 1: 3”x4” Brown ceramic tile
Layer 2: Trace brown grout Layer 3: Beige mastic
Layer 4: Wood window sill
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A N/A
N/A
11035-KLE-
Bedroom 1
Black rubber window glazing gasket (on 4’x3’ metal-framed window)
ND N/A
11035-KLE-
Restroom
Layer 1: 4”x4” White/yellow ceramic tile
Layer 2: Yellow ceramic tile
Layer 3: Yellow mastic Layer 4: Trace brown fibrous material
L1: ND
L2: ND
L3: ND
L4: ND
N/A
N/A
N/A N/A
11035-KLE-
Restroom Black rubber window glazing gasket (on 3’x2’ metal-framed window)
ND N/A
11035-KLE-
Restroom
Layer 1: Black plastic sink drain gasket
Layer 2: Black fibrous rubber sink drain gasket
Layer 3: Yellow/clear mastic (on enamel coated metal sink)
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-
KLE-08
Kitchen/ Living room
Layer 1: Brown SVF (w/ geometric pattern) Layer 2: Gray paper backing w/ tan mastic Layer 3: OSB
Layer 4: Wood (beneath black mastic) Layer 5: Black mastic
L1: ND
L2: 52%
L3: ND
L4: ND
L5: ND
N/A
Chrysotile
N/A
N/A
N/A
11035-KLE-
Kitchen/ Living room
Layer 1: 4”x4” White ceramic tile (w/ gray specks) and white grout
Layer 2: Orange mastic (strewn about as loose debris)
L1: ND
L2: ND
N/A
N/A
EHSI Project 11035 November 10th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARKS SERVICE
LAKE OZETTE – KLEIVA PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-KLE-
Kitchen/
Living room
Layer 1: Red brick w/ black coating (in places)
Layer 2: Gray mortar (strewn about as loose debris)
L1: ND
L2: ND
N/A
N/A
11035-KLE-
Exterior, Roof
Layer 1: Rolled down black asphaltic roofing w/ black granules and black asphaltic tar
Layer 2: Rolled down black asphaltic roofing w/ black granules and black asphaltic tar
(under wood roof shingles)
L1: ND
L2: ND
N/A
N/A
11035-KLE-
Exterior, Roof
Layer 1: Rolled down black asphaltic roofing w/ black granules and black asphaltic tar Layer 2: Rolled down black asphaltic roofing w/ black granules and black asphaltic tar
(under wood roof shingles) Layer 3: Trace white substance
L1: ND
L2: ND
L3: ND
N/A
N/A
N/A
11035-KLE-
Kitchen/
Living room
Off-white bare GWB (strewn about as loose debris)
ND N/A
11035-KLE-
Kitchen/ Living room
2” OD white plastic gasket (associated w/ hot water tank inlet/outlet)
ND N/A
11035-KLE-
Kitchen/ Living room
Off-white/gray pipe dope (on 1” OD pipe connections to hot water tank)
ND N/A
11035-KLE-
Kitchen/ Living room
Black rubber window glazing gasket (on 3’x4’ metal-framed window)
ND N/A
11035-KLE-
17QA
Kitchen/
Living room
Black rubber window glazing gasket w/ woven fibrous interior (on 4’x5’ metal-framed window)
ND N/A
11035-KLE-
Exterior, Beneath Kitchen/
Living room
Light gray/gray pipe dope (on
2” OD metal drain pipe connections)
ND N/A
EHSI Project 11035 November 10th, 2017
TABLE 1
SUMMARY OF ASBESTOS BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARKS SERVICE
LAKE OZETTE – KLEIVA PROPERTY
SAMPLE
NUMBER
SAMPLE
LOCATION
MATERIAL DESCRIPTION
ASBESTOS
TYPE OF
ASBESTOS
11035-KLE-
Bedroom 1
Layer 1: Silver foil Layer 2: White paper wrap w/ fibrous mesh reinforced interior Layer 3: Yellow fiberglass TSI
Layer 4: Wood w/ debris (unused insulation, stacked above bed)
L1: ND
L2: ND
L3: ND
L4: ND
N/A N/A
N/A
N/A
11035-KLE-
Restroom
Layer 1: Green carpet Layer 2: Off-white foam backing w/ brown mesh (loose roll, not installed)
L1: ND
L2: ND
N/A N/A
11035-KLE-
Kitchen/ Living room
Layer 1: Multi-colored carpet
Layer 2: Off-white mastic
Layer 3: Beige backing Layer 4: Tan mastic w/ woven backing Layer 5: Silver tape (on wood)
L1: ND
L2: ND
L3: ND
L4: ND
L5: ND
N/A
N/A
N/A N/A
N/A
11035-KLE-
22QA
Kitchen/
Living room
Brown wood patterned coating on white contact paper w/paint
ND N/A
KEY: bold = bold text indicates asbestos-containing layer, GWB = gypsum wall board, ND = non-detect, N/A = not applicable, OD = outer diameter, OSB = oriented strand board, SVF = sheet vinyl flooring, w/ = with
Table 2 summarizes materials identified by EHSI as containing greater than 1% asbestos fibers during its survey, and un-sampled materials assumed to be ACM. The Table 2 Summary of Asbestos Containing Materials is for engineering cost estimating purposes and is not intended for bid quantifications.
TABLE 2
SUMMARY OF ASBESTOS-CONTAINING MATERIALS
NATIONAL PARK SERVICE
LAKE OZETTE – KLEIVA PROPERTY
ASBESTOS MATERIAL DESCRIPTION LOCATION QUANTITY
Non-ACM Beige and brown SVF (w/ large broken rock pattern) w/ ACM gray paper backing w/ ACM tan mastic on wood [Sample # 01]
Bedroom 1 125 SF
Non-ACM SVF (w/ geometric pattern) w/ ACM gray paper backing w/ ACM tan mastic on OSB on non-ACM black mastic on wood [Sample # 08]
Kitchen/
Living room
550 SF
KEY: ACM = asbestos containing material, bold = bold text indicates asbestos-containing layer, OSB
= oriented strand board, SF = square feet, SVF = sheet vinyl flooring, w/ = with
ACM identified in this survey should not be disturbed unless handled by personnel who are properly trained and certified in asbestos work. Demolition and/or renovation activities by contractors may expose concealed suspect ACM. Contractors should be aware of the potential
EHSI Project 11035 November 10th, 2017 for concealed suspect ACM and have pre-planned contingencies for the handling of suspect
ACM discovered during renovation and/or demolition work. Any concealed suspect ACM material that was not sampled or was assumed to be ACM and included in this report, must be treated as ACM until proven otherwise by a Certified AHERA Building Inspector and a certified laboratory. Contingency plans should include stopping work on identification of concealed suspect ACM, evacuation of the area, and sampling by a Certified AHERA Building
Inspector. Concealed suspect material may include, but is not limited to: non-fiberglass pipe or roof drain insulation; spray-applied coatings; cementitious board; asphalt or paper vapor barriers; vinyl floorings and mastics.
2.4.2 Lead-Containing Paint and Building Materials
Thirteen (13) samples were analyzed for lead using the X-Ray fluorescence (XRF) analyzer.
Results marked with “< LOD” are less than the limit of detection. XRF paint sample results ranged from 5 milligrams of lead per square centimeter (mg Pb/cm2) to < LOD mg Pb/cm2.
Bolded results indicate materials coated with “lead-based paint” (e.g., 1.0 mg/cm2) as defined by USEPA regulation 40CFR745 and Washington State Commerce regulation WAC 365-230. The results are provided in Table 3 of this report.
Table 3 summarizes XRF lead samples, including sample number, material description, substrate, color, location and analytical results.
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARKS SERVICE
LAKE OZETTE – KLEIVA PROPERTY
Read
Component Substrate Color Building Room
Lead Conc.
(mg/cm2)
1 NIST Check Wood Red Kleiva Property N/A 0.98
2 NIST Check Wood Red Kleiva Property N/A 0.99
3 NIST Check Wood Red Kleiva Property N/A 0.99
4 Structural Beam Wood Dark Brown Kleiva Property Kitchen/Living
Room
<LOD
5 Door Frame Wood Dark Brown Kleiva Property Kitchen/Living
Room
<LOD
6 Window Frame Ceramic Brown Kleiva Property Kitchen/Living
Room
7 Wall Fiber Board Light Brown Kleiva Property Kitchen/Living
Room
<LOD
8 Door Fiber Board Brown Kleiva Property Hall <LOD
9 Counter Ceramic Off White Kleiva Property Bathroom 5
Toilet Base
Framing Wood Brown Kleiva Property Bathroom
<LOD
11 Cabinet Wood Brown Kleiva Property Bathroom <LOD
12 Shelf Metal White Kleiva Property Bathroom <LOD
13 Fascia Wood Dark Brown Kleiva Property Exterior <LOD
14 Gutter Plastic Brown Kleiva Property Exterior <LOD
EHSI Project 11035 November 10th, 2017
TABLE 3
XRF SAMPLING
SUMMARY OF PAINTED COMPONENTS AND MATERIALS
NATIONAL PARKS SERVICE
LAKE OZETTE – KLEIVA PROPERTY
Read
Component Substrate Color Building Room Lead Conc.
(mg/cm2)
15 NIST Check Wood Red Kleiva Property N/A 0.9
16 NIST Check Wood Red Kleiva Property N/A 0.91
17 NIST Check Wood Red Kleiva Property N/A 0.89
18 NIST Check Wood Red Kleiva Property N/A 0.94
19 NIST Check Wood Red Kleiva Property N/A 0.91
20 NIST Check Wood Red Kleiva Property N/A 0.93
21 Wall Wood Dark Brown Kleiva Property Exterior <LOD
22 Window Trim Wood Dark Brown Kleiva Property Exterior <LOD
23 NIST Check Wood Red Kleiva Property N/A 0.89
24 NIST Check Wood Red Kleiva Property N/A 0.89
25 NIST Check Wood Red Kleiva Property N/A 0.9
26 NIST Check Wood Red Kleiva Property N/A 0.94
27 NIST Check Wood Red Kleiva Property N/A 0.92
28 NIST Check Wood Red Kleiva Property N/A 0.9
Key: N/A = not applicable, <LOD = less than the limit of detection
In addition to the XRF samples, EHSI collected two (2) bulk QA samples for laboratory analysis. The bulk sample results were both less than the reporting limit. Building materials and paint containing detectable levels of lead are considered regulated by DOSH. Any contractors disturbing materials with detectable amounts of lead should conduct training and a negative exposure assessment in accordance with DOSH regulations.
Table 4 summarizes bulk QA lead samples, including sample number, material description, substrate, color, location, and analytical results.
Copies of the analytical laboratory report and field data forms for lead paint are included in
Appendix B of this report.
TABLE 4
SUMMARY OF LEAD BULK SAMPLING AND ANALYTICAL RESULTS
NATIONAL PARKS SERVICE
LAKE OZETTE – KLEIVA PROPERTY
SAMPLE NUMBER LOCATION
COMPONENT/
SUBSTRATE
COLOR
RESULTS
% Pb by WT
11035-KLE-Pb01 Exterior Chimney/ Brick & Mortar Red &
Gray <0.0066
11035-KLE-Pb02 Exterior Siding & Trim/ Wood Brown <0.0028 Key: Pb = lead, WT = weight
EHSI Project 11035 November 10th, 2017
DOSH requires employers to conduct a hazard assessment and take appropriate worker protection precautions whenever disturbing materials that have detectable quantities of lead.
Since the type of work planned (e.g., sawing, grinding, demolition) will disturb the lead-containing materials, the contractor should perform an initial exposure assessment to determine if additional personal protective measures and work practices are required beyond the initial exposure assessment.
2.4.3 Toxicity Characteristic Leaching Procedure Sampling
Ecology requires testing using the “toxicity characteristic leaching procedure” (TCLP) and segregation of construction debris if it is potentially contaminated with dangerous waste (e.g., lead-containing paint/lead-containing materials). Ecology has set a dangerous waste threshold for leachable lead at 5.0 milligrams of lead per liter (mg/L).
At the request of the NPS, a TCLP was conducted by EHSI as part of the Limited Lead and Asbestos Survey. The results of that lead-TCLP analysis indicate leachable lead present in the anticipated demolition waste stream at a concentration of <0.5 mg/L. A detailed list of the materials included in the TCLP sample are provided in Appendix F.
It should be noted that this TCLP was done on behalf of NPS for disposal cost estimating purposes. It is recommended that the contractor take their own TCLP test of their demolition waste stream including the option to not TCLP specific materials based on the ability to recycle metal and concrete painted building materials.
2.4.4 Polychlorinated Biphenyls
Ballasts
EHSI did not observe any ballasts associated with fluorescent light fixtures on the Kleiva property.
2.4.5 Mercury-Containing Fluorescent Light Tubes and CFL Bulbs
EHSI did not observe any mercury-containing fluorescent light tubes, CFL bulbs, or HID lamps on the Kleiva property.
3.0 LIMITATIONS
This survey was limited to those materials accessible using standard survey methods. Limited representative destructive inspection was accomplished. All suspect materials present were accessible for sampling.
This survey was limited to the chemicals and materials identified herein. No effort was made to identify hazardous materials in soil, water, or air, other than those listed herein. Any survey regardless of how extensive can miss concealed materials. Contractors should be aware of the potential that demolition activities may expose concealed suspect ACM and should have preplanned contingencies for handling these materials when discovered during demolition work. Any concealed, suspect ACM material that was not sampled or that was assumed to be
ACM by this survey report when encountered must be treated as ACM until sampled by a Certified AHERA Building Inspector and analyzed by a certified laboratory.
EHSI Project 11035 November 10th, 2017
4.0 STANDARD OF CARE
The recommendations and conclusions contained in this report represent the professional opinions of EHSI. These opinions are derived in accordance with federal, state, and local environmental and health and safety laws and regulations. This survey was accomplished in accordance with applicable federal, state, and local regulations and industry standards in effect at the time. Other than this, no other warranty is implied or intended.
5.0 CERTIFIED AHERA BUILDING INSPECTORS
The Certified AHERA Building Inspectors listed below surveyed the property on October 4th, 2017, in accordance with federal, state, and local requirements.
Brett Racine Mike Ruark
Certified AHERA Building Inspector Certified AHERA Building Inspector Certificate Number: 1628680 Certificate Number: 163007
Expiration Date: July 26, 2018 Expiration Date: September 6, 2018
Appendix A
APPENDIX A
Asbestos Analytical Laboratory Report and Field Data Forms
Nick Ly, Technical Director
Client Project: 11035-03
Location: Kleiva Property
Dear Mr. Peterson, Enclosed please find test results for the 2 sample(s) submitted to our laboratory for analysis on
10/10/2017.
Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in accordance with both EPA 600/M4-82-020, Interim Method for the Determination of Asbestos in Bulk Insulation Samples and EPA 600/R-93/116
Method for the Determination of Asbestos in Bulk Building Materials.
For samples containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by calibrated visual estimation.
For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low concentrations of asbestos.
The detection limit for the calibrated visual estimation is <1%, 400 point counts is 0.25% and 1000 point counts is 0.1%
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with.
Sincerely, Enc.: Sample Results
October 13, 2017
Nick L T hnical D
Rory Peterson
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
RE: Bulk Asbestos Fiber Analysis; NVL Batch # 1717972.00
< Client:
Address:
Attention: Mr. Rory Peterson
Kleiva Property
Client Project #: 11035-03
Samples Received: 2
By Polarized Light Microscopy
Bulk Asbestos Fibers Analysis
EHS International
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Method: EPA/600/R-93/116
& EPA/600/M4-82-020
Samples Analyzed: 2
Project Location:
Batch #: 1717972.00
Date Received: 10/10/2017
17098187Lab ID: Client Sample #:
Location: Kleiva Property
11035-KLE-17QA
Layer 1 of 1 Description: Black flexible material with fibrous elements
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Calcareous binder 8%Synthetic fibers None Detected ND
17098188Lab ID: Client Sample #:
Location: Kleiva Property
11035-KLE-22QA
Layer 1 of 1 Description: White fibrous paper material with paint
Non-Fibrous Materials: Other Fibrous Materials:% Asbestos Type: %
Binder/Filler, Paint 77%Cellulose None Detected ND
Note: If samples are not homogeneous, then subsamples of the components were analyzed separately. All bulk samples are analyzed using both EPA
600/R-93/116 and 600/M4-82-020 Methods with the following measurement uncertainties for the reported % Asbestos (1%=0-3%, 5%=1-9%, 10%=5-15%, 20%=10-30%, 50%=40-60%). This report relates only to the items tested. If sample was not collected by NVL personnel, then the accuracy of the results is limited by the methodology and acuity of the sample collector. This report shall not be reproduced except in full, without written approval of NVL
Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any other agency of the US Government
Client
Jacob LaugesonAnalyzed by:
Nick LyReviewed by:
10/12/2017 Date:
10/13/2017Date:
Sampled by:
EHS International 1717972.00
Company NVL Batch Number
Total Number of Samples
Kleiva Property
5 DaysTAT
10/17/2017Due Date 9:25 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-03Project Name/Number: Project Location:
Sample ID Description A/RLab ID
ASBESTOS LABORATORY SERVICES
Subcategory
Item Code
PLM Bulk
Metals
ASB-02 EPA 600/R-93-116 Asbestos by PLM <bulk>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-KLE-17QA1 A17098187
11035-KLE-22QA2 A17098188
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Jacob LaugesonAnalyzed by
Results Called by
NVL
NVL
10/10/17
10/12/17
Print Name
Entered By: Umer Khan
Date: 10/10/2017
Time: 9:30 AM
Special
Instructions:
Appendix B
APPENDIX B
Lead Laboratory Reports and Field Data Forms
RE: Metals Analysis; NVL Batch # 1717978.00
Dear Mr. Peterson, October 13, 2017
EHS International
Rory Peterson
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.
This report is considered highly confidential and will not be released without your approval.
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.
Sincerely, Shalini Patel, Laboratory Analyst
Analysis Report Total Lead (Pb)
Kleiva Property
EHS InternationalClient:
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Mr. Rory PetersonAttention:
Address:
Project Location: Samples Received: 2
Samples Analyzed: 2
Client Project #: 11035-03
Batch #: 1717978.00
Date Received: 10/10/2017
Lab ID Client Sample #
Sample
Weight (g)
Results in mg/Kg
Results in percent
RL in mg/Kg
Matrix: Paint
Method: EPA 3051/7000B
17098199 11035-KLE-Pb01 0.1517 66 < 66 0.0066<
17098200 11035-KLE-Pb02 0.3614 28 < 28 0.0028<
ClientSampled by:
Yasuyuki HidaAnalyzed by:
Shalini PatelReviewed by:
10/13/2017Date Analyzed:
10/13/2017Date Issued:
Bench Run No: 2017-1013-2 mg/ Kg =Milligrams per kilogram RL = Reporting Limit
Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit Note : Method QC results are acceptable unless stated otherwise.
Unless otherwise indicated, the condition of all samples was acceptable at time of receipt.
Shalini Patel, Laboratory Analyst
EHS International 1717978.00
Company NVL Batch Number
Total Number of Samples
Kleiva Property
5 DaysTAT
10/17/2017Due Date 9:25 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-03Project Name/Number: Project Location:
Sample ID Description A/RLab ID
LEAD LABORATORY SERVICES
Subcategory
Item Code
Flame AA (FAA)
Metals
FAA-02 EPA 7000B Lead by FAA <paint>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-KLE-Pb011 A17098199
11035-KLE-Pb022 A17098200
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Yasuyuki HidaAnalyzed by
Results Called by
NVL
NVL
10/10/17
10/13/17
Print Name
Entered By: Umer Khan
Date: 10/10/2017
Time: 9:40 AM
Special
Appendix C
APPENDIX C
Certified AHERA Building Inspector Certificates
Appendix D
APPENDIX D
Laboratory Certifications for Asbestos and Lead Analysis acknowledges that
NVL Laboratories, Inc.
General Requirements for the Competence of Testing and Calibration Laboratories
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE
ENVIRONMENTAL LEAD
ENVIRONMENTAL MICROBIOLOGY
FOOD
UNIQUE SCOPES
Scope of Accreditation
Scope of Accreditation
William Walsh, CIH
Chairperson, Analytical Accreditation Board
Cheryl O. Morton
Managing Director, AIHA Laboratory Accreditation Programs, LLC
NVL Laboratories, Inc. 101861
Industrial Hygiene Laboratory Accreditation Program (IHLAP)
Initial Accreditation Date: 04/01/1997
IHLAP Scope
Category
Field of Testing (FoT) Technology sub-type/
Detector
Published Reference
Method/Title of In-house Method
Method Description or Analyte for internal methods only)
Spectrometry Core
Asbestos/Fiber
Microscopy Core
Miscellaneous Core
NVL Laboratories, Inc. 101861
Environmental Lead Laboratory Accreditation Program (ELLAP)
Initial Accreditation Date: 02/07/1997
Field of Testing (FoT) Technology sub-type/
Detector Method
Method Description for internal methods only)
Paint
Soil
Settled Dust by Wipe
Airborne Dust
Appendix E
APPENDIX E
Sample Location Drawings for Asbestos, Lead, and TCLP
KITCHEN
BEDROOM 2 BEDROOM 1BATH
OVEN
TANK
SL-1
KLEIVA
HOUSE
PROJECT NORTH
KLEIVA HOUSE
NOT TO SCALE
EHSI PROJECT #:
SCALE:
SURVEY DATES:
DRAWN BY:
INSPECTORS:
PROJECT MANAGER:
ISSUE DATE:
K
LE
IV
A
P R
O P
E R
TY
E
A S
T S
H O
R E
LA
K
E O
ZE
TT
E
U S
D E
P A
R
TM
E N
T O
F
TH
E
IN
TE
R
IO
R
N P
S P
O R
T A
N G
E
LE
S , W
A
GENERAL NOTES
1. DRAWING IS SCHEMATIC AND SAMPLE LOCATIONS ARE
APPROXIMATE.
2. REFER TO REPORT FOR MORE INFORMATION ABOUT
THE SAMPLED MATERIALS.
1011 SW Klickitat Way, Suite 104
Seattle, Washington 98134
Ph: 206.381.1128
Fax: 206.254.4279
EHS-International, Inc.
SAMPLE LEGEND
BULK ASBESTOS SAMPLE LOCATIONS11035-KLE-XX
P R
O
JE
C T
P R
O P
E R
T Y
I D
S A
M P
L E
# PROPERTY ID:
HAU = HAUBRICH
KLE = KLEIVA
BULK LEAD SAMPLE LOCATIONS11035-KLE-PbXX
BULK TCLP SUB-SAMPLE11035-KLE-TCLP-XXA
11035-KLE-TCLP-01D
11035-KLE-TCLP-01H
11035-KLE-21 11035-KLE-17
11035-KLE-16
11035-KLE-18
11035-KLE-10 11035-KLE-TCLP-01I
11035-KLE-11
11035-KLE-14
11035-KLE-TCLP-01F 11035-KLE-TCLP-01A
11035-KLE-Pb02
11035-KLE-TCLP-01C
11035-KLE-09
11035-KLE-13
11035-KLE-08
11035-KLE-01
11035-KLE-22
11035-KLE-03
11035-KLE-TCLP-01E
11035-KLE-TCLP-01J
11035-KLE-TCLP-01B
11035-KLE-12
11035-KLE-TCLP-01E
11035-KLE-05
11035-KLE-TCLP-01G 11035-KLE-19
11035-KLE-07
11035-KLE-06
11035-KLE-20
11035-KLE-Pb01
11035-KLE-04
11035-KLE-02
11035-KLE-15
Appendix F
APPENDIX F
Lead TCLP Laboratory Reports and Field Data Forms
RE: Metals Analysis; NVL Batch # 1717976.00
Dear Mr. Peterson, October 12, 2017
EHS International
Rory Peterson
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Enclosed please find the test results for samples submitted to our laboratory for analysis.
Preparation of these samples was conducted following protocol outlined in EPA Method SW 846
-3051 unless stated otherwise. Analysis of these samples was performed using analytical instruments in accordance with U.S. EPA, NIOSH, OSHA and other ASTM methods.
For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg/Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in mg/Kg (ppm) , Percent (%) or mg/cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug/ft . TCLP samples are reported in mg/L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug/filter and ug/m . Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested and are not blank corrected.
For recent regulation updates pertaining to current regulatory levels or permissible exposure levels, please call your local regulatory agencies for more details.
This report is considered highly confidential and will not be released without your approval.
Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks.
Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206-547-0100 or 1-888-NVLLABS.
Sincerely, Lab ID Client Sample #
Results in mg/L
RL
mg/ L
Results in ppm
Analysis Report
Kleiva Property
EHS InternationalClient:
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Mr. Rory PetersonAttention:
Address:
Project Location: Samples Received: 1
Samples Analyzed: 1
Client Project #: 11035-03
Batch #: 1717976.00
Date Received: 10/10/2017
Toxicity Characteristic Leaching Procedure - Lead (Pb)
Matrix: Bulk
Method: EPA 1311/7000B
17098196 11035-KLE-TCLP-01 0.5 < 0.5 < 0.5
ClientSampled by:
Yasuyuki HidaAnalyzed by:
Nick LyReviewed by:
Note : Method QC results are acceptable unless stated otherwise.
mg/ L =Milligrams per liter RL = Reporting Limit ppm = parts per million '<' = Below the reporting Limit
10/12/2017Date Analyzed:
10/12/2017Date Issued:
Bench Run No: 2017-1011-4
Unless otherwise indicated, the condition of all samples was acceptable at time of receipt.
EHS International 1717976.00
Company NVL Batch Number
Total Number of Samples
Kleiva Property
5 DaysTAT
10/17/2017Due Date 9:25 AMTime
(206) 254-4279Fax roryp@ehsintl.comEmail
Project Manager Mr. Rory Peterson
(206) 381-1128
(425) 766-8342Cell
Phone
Rush Samples
Rush TAT
NoAH
11035-03Project Name/Number: Project Location:
Sample ID Description A/RLab ID
LEAD LABORATORY SERVICES
Subcategory
Item Code
Flame AA (FAA)
Metals
TCLP-1 EPA 1311/7000B Lead by FAA <TCLP>
1011 SW Klickitat Way. Suite 104
Seattle, WA 98134
Address
11035-KLE-TCLP-011 A17098196
Office Use Only Print Name Company Date TimeSignature
Faxed Emailed
Company Date TimeSignature
ClientSampled by
Umer KhanReceived by
ClientRelinquished by
Yasuyuki HidaAnalyzed by
Results Called by
NVL
NVL
10/10/17
10/12/17
Print Name
Entered By: Mohammed Jamal
Date: 10/10/2017
Time: 9:38 AM
Special