RFI_30_Attachment_0004.pdf

PDF 2 MB Posted

Attached to
SEMO 218940, Develop Selma Interpretive Center at Federal contract opportunity
Solicitation number
140P2023R0022
Issued by
Department of the Interior National Park Service National Office

About this file

This document contains utility relocation plans and specifications for a water and sewer infrastructure project in Selma, Alabama. The plans require the contractor to remove and replace approximately eight existing sewer laterals with four-inch PVC laterals from as close to buildings as practical; install new water services including taps, corp stops, backflow preventers, meter boxes with meters and curb stops from the water main to buildings; replace an existing six-inch water main with new six-inch ductile iron water main; install fire hydrant assemblies and gate valves; replace brick pavers to match existing; and replace existing gas service lines. The related federal contract opportunity is for the development of the Selma Interpretive Center along the Selma to Montgomery National Historic Trail in Selma, Alabama, being solicited by the National Park Service with a solicitation number of 140P2023R0022.

View the file

Other files for this federal contract opportunity

Other files attached to SEMO 218940, Develop Selma Interpretive Center at, newest first.
File Type Posted
B08_Amendment_9_Attachment_3_SF1442_Submittal_Register_0009.pdf PDF
Sol_140P2023R0022_Amd_0009.pdf PDF
B08_RFP_140P2023R0022_Amendment_0009-6_20_23_0009.pdf PDF
B08_Amendment_9_Attachment_1_SF1442_Conformed_Solicitation_140P2023R0022_0009.pdf PDF
B08_Amendment_9_Attachment_2__Section_J_Attachment_4_Contract_Price_Schedule_SEMO_218940_0009.xlsx XLSX spreadsheet
B08_RFP_140P2023R0022_Amendment_0008-6_15_23_0008.pdf PDF
B08_Amendment_0008_Attachment_1_Pre-Bid_RFIs_and_NPS_Responses_6_15_23_0008.pdf PDF
B08_Amendment_0008_Attachment_2_Pre-Bid_RFIs_and_NPS_Responses_6_15_23_Attachment_for_RFI_15_0008.pdf PDF
Sol_140P2023R0022_Amd_0008.pdf PDF
B08_RFP_140P2023R0022_Amendment_0007-6_7_23_0007.pdf PDF
B08_Amendment_7_Attachment_1_SF1442_Conformed_Solicitation_140P2023R0022_0007.pdf PDF
Sol_140P2023R0022_Amd_0007.pdf PDF
Sol_140P2023R0022_Amd_0006.pdf PDF
B08_RFP_140P2023R0022_Amendment_0006-6_6_23_0006.pdf PDF
B08_Amendment_0006_Attachment_2_SPECIFICATIONS_ADDENDUM_1_6_6_23_0006.pdf PDF
B08_Amendment_0006_Attachment_1_SEMO_218940_Late_RFIs_and_NPS_Responses_6_6_23_0006.pdf PDF
B08_RFP_140P2023R0022_Amendment_0005-5_30_23_0005.pdf PDF
Sol_140P2023R0022_Amd_0005.pdf PDF
Sol_140P2023R0022_Amd_0004.pdf PDF
B08_RFP_140P2023R0022_Amendment_0004-5_15_23_0004.pdf PDF
B08_Amendment_0003_Attachment_1_Pre-Bid_RFI_and_NPS_Responses_Round_2_Received_by_5_10_23_0003.pdf PDF
B08_RFP_140P2023R0022_Amendment_0003-5_12_23_0003.pdf PDF
Sol_140P2023R0022_Amd_0003.pdf PDF
B08_Amendment_0002_Attachment_1_Pre-Bid_RFI_and_NPS_Responses_0002.pdf PDF
Sol_140P2023R0022_Amd_0002.pdf PDF
B08_RFP_140P2023R0022_Amendment_0002-4_27_23_0002.pdf PDF
B08_RFP_140P2023R0022_Amendment_0001-4_18_23_0001.pdf PDF
B08_Amendment_0001_Attachment_1_Pre-Bid_Site_Visit_Sign-In_0001.pdf PDF
Sol_140P2023R0022_Amd_0001.pdf PDF
B08_Amendment_0001_Attachment_2_Pre-Bid_Site_Visit_Powerpoint_Presentation_0001.pptx PPTX presentation
B08_Solicitation_140P2023R0022_SEMO_218940.pdf PDF
B08_Section_J_Attachment_2_Specifications_Volume_2.pdf PDF
Sol_140P2023R0022.pdf PDF
B08_Section_J_Attachment_1_Specifications_Volume_1.pdf PDF
B08_Section_J_Attachment_6_Proposal_Submission_Package_Forms.pdf PDF
B08_Section_J_Attachment_5_General_Decision_Number___AL20230080.pdf PDF
B08_Section_J_Attachment_4_Contract_Price_Schedule_SEMO_218940.xlsx XLSX spreadsheet
B08_Section_J_Attachment_3_Drawings.pdf PDF
Show all 38

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

I I

REQ'D 6" SL££!/£

'J a d□

REQUIRED: REMOVE AND REPLACE EXISTING

SEWER LATERALS WITH 4-" DI LATERALS,

FROM AS CLOS£ TO TH£ BUILDING FACE

AS PRACTICAL, TO A POINT 3' BEYOND

TH£ WATER MAIN. PROVIDE 2-WAY

CLE:ANOUT WITH BRASS CAP. NORTH SID£

OF WATER AVENUE ONLY.

(ASSUM£ 8 LATERALS)

-...... REQ'D NEW

WATER SERVICE

I • -

I l •

"R£Q'D NEW WA7ER SERVICE" SHALL

INCLUDE: TAP, CORP STOP, BACKFLOW

PREVENTER, MEIER BOX W/M£7ER AND

CURB STOP, AND ¾" COPPER PIP£

FROM TH£ MAIN TO AS CLOS£ TO TH£

BUILDING AS PRACTICAL

REQ'D NEW

REQ'D NEW WATER SERVICES

WATER SERVICE

ow

[fill •

R£Q'D FIR£ HYDRANT

ASSEMBLY, 6" GATE VALVE

ASSEMBLY

REQ'D REMOVE AND REPLACE

EX 6" WATER MAIN WfTH NEW

6" DUCTILE IRON WATER MAIN

Begin Project Begin Work Sta -0+06 o+oo 1+00 2+o0

REQ'D HANDICAP

RAMP

Ex Handicap Romp (Remove)

Ex Ped Signal (To Remain)

REQ'D HANDICAP

RAMP

Ex Handicap Romp (Remove)

To Edmund Pettis Bridge

.!a :c

Ill. -

II'"" •

Ex Traffic Pole (To Remain)

I •

II""" II'"" a- ... &..

[fill •

'J a

I

REQ'D FIR£

HYDRANT ASSEMBLY

6+00

[fill

Ex 24" RC Pipe Sanitary Sewer (To Remain)

R£Q'D REMOVE AND REPLACE

£X GAS SERVICE LIN£

(BY OTHERS)

End Project (Add/Alt Bid) End Work (Add/Alt Bid) Sta 6+47

REQ'D 6" T££

6" GATE: VALVE ASSEMBLY

6" SLEEVE

60 LF 6" DI

7+00

R£Q'D BRICK PAV£RS - MATCH

MATERIALS, COLOR, PAT7ERN, £TC

TO TH£ NORTH SID£ £XAC1L Y

• Existing Awning Post

(To Remain)

• I • •

I 5 I)

I • • a

I

REQ'D FIR£

HYDRANT ASSEMBLY

REQ'D 6" T££

3-6" GATE VALVE ~fiMBLl£S

6" SL.£

4-0 LF DI

REQ'D REMOVE AND REPLACE

£X GAS SERVICE LIN£

(BY OTHERS)

I

REQ'D/6• E

6" GATE VAL!VE

2-6" S EVES

15 LF " DI

SS£MBLY

Rim 134.15 Inv 120.27

EXISTING MANHOLE

I I I I I I I I I _....,_ I I I

I I I I I I

I

I I I

I I I I I I

I I I I

I I I I I I I •

REQ'D NEW

WATER SERVICES

End Project (Bose Bid) End Work (Base Bid) Sta 3+84

4+o0

[fill

REFERENCE

PROJECT NO.

HPP-A 169(900)

"II'"

[fill

Ex Water Service (To be Abandoned)

REQ'D REMOVE AND REPLACE

£X 6" WATER MAIN WfTH NEW

6" DUCTILE IRON WATER MAIN

WATER.AVENUE

[fill •

REQ'D NEW

WATER SERVICE

II'"" .,,.

REQ'D REMOVE AND REPLACE

£X GAS SERVICE LIN£

(BY OTHERS)

5+o0

Ex 24" RC Pipe Sanitary Sewer to Remain

Ex Gas Line to Remain

[fill

[fill

[fill

2009 4

II'"" "'I"' • r-

GoooWYN. MILlS

UWOOD, INC.

l!IIGINliliRING

ARCIUl'IICftJRB

LANDSCAPB==ARCHffl!Cl1JRB==

PLANNING

2880 Eaalchaae Lane Suite200

Ma11gumery Alabana 38117 Mgiling Addceag

PO Bale 242128 Ma 1lgumery Alabana 38124

Phone: (334) 271-3200 Fax: (334) 272-1566

Bimlngham

Mable

Andalusia

V11111011

WATER

AVENUE

UTILITY

RELOCATIONS

CITY OF SELMA

5-7-135 Horiz Scale: 1 '=20' Vert Scale: NTS l11ue date Ptel16ay

RIIII

Engineer:

Drawn by:

UTILITY

RELOCATION

PLANS

File details come from the government source that posted it. Updated .