12 LBNL ES_H Manual (PUB-3000) Chapter 43 Non Ionizing Radiation.pdf
PDF 250 KB Posted
- Attached to
- UPDATED ALS SHB pulsed RF HPA Federal contract opportunity
- Solicitation number
- AM202603-25
- Issued by
- Department of Energy
About this file
This document is a policy and procedures chapter from the Lawrence Berkeley National Laboratory (Berkeley Lab) addressing non-ionizing radiation (NIR) safety and exposure control.
The Berkeley Lab NIR Program establishes safety protocols to ensure personnel exposure to non-ionizing radiation does not exceed Threshold Limit Values (TLVs) for the human eye or skin. The program applies to Berkeley Lab employees, visitors, affiliates, and subcontractors working with NIR sources including infrared light, magnetic fields, microwave radiation, radio frequency, artificial ultraviolet radiation, and visible light. Laser exposures and acoustic noise are covered under separate policies. The Division Director enforces the program, the Environment, Health & Safety (EHS) Division arranges NIR assessments and establishes controls, and Supervisors/Activity Leads ensure proper training and implementation through the Work Planning and Control (WPC) system. NIR Equipment Users must receive on-the-job training prior to unsupervised use, follow all WPC Activity procedures, and immediately report suspected exposures. Exposure limits comply with the 2016 ACGIH Threshold Limit Values for Chemical Substances and Physical Agents and are frequency- or wavelength-dependent across multiple radiation types. Control methods prioritize engineering controls where feasible, including access restrictions for magnetic fields exceeding 5 Gauss, Faraday cages for RF and microwave radiation, and barriers/personal protective equipment for ultraviolet radiation. Personnel with implanted medical devices receive special consideration with stricter exposure limits. The program references 10 CFR 851 Worker Safety and Health Program and the C95 IEEE/ANSI Standard on Human Exposure to Radio Frequencies as governing requirements.
View the file
Other files for this federal contract opportunity
Show all 30
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5/5/2020 PUB-3000 Chapter 43 | NON-IONIZING RADIATION | REVISED 10/14 https://www2.lbl.gov/ehs/pub3000/CH43.html 1/10
Chapter 43
NON-IONIZING RADIATION
Contents
Approved by Greta Toncheva Revised 5/18
43.1 Policy
43.2 Scope
43.3 Applicability
43.4 Exceptions
43.5 Roles and Responsibilities
43.6 Definitions
43.7 Required Work Processes
Work Process A. Non-ionizing Radiation Flowchart Work Process B. Exposure Limits Work Process C. Methods of Exposure Control Work Process D. Additional Information
43.8 Source Requirements
43.9 Reference Documents
NOTE:
. . . . . Denotes a new section.
. . . . . . . . Denotes the beginning of changed text within a section.
. . . . . . . . Denotes the end of changed text within a section.
43.1 Policy
The Lawrence Berkeley National Laboratory (Berkeley Lab) Non-ionizing Radiation (NIR) Program is designed to provide a safe working environment for staff that ensures NIR exposure does not exceed the Threshold Limit Values (TLV) for the human eye or skin. The NIR Program at Berkeley Lab ensures personnel are protected from NIR exposure hazards including:
Infrared light
Magnetic fields
Microwave radiation
Radio frequency
Artificial ultraviolet (UV) radiation https://www2.lbl.gov/ehs/pub3000/CH43.html 2/10
Visible light
Note: Laser and acoustic (noise) exposures are covered in separate policies.
43.2 Scope
Non-ionizing Radiation (NIR) refers to electromagnetic radiation with insufficient energy to release a bound electron from an atom. NIR includes the following categories of radiation: ultraviolet (UV), visible light, infrared, radio frequency, microwave, and magnetic fields. (Lasers are covered in the Laser Safety Program.)
43.3 Applicability
This program applies to Berkeley Lab employees, casual and participating visitors, affiliates, and subcontractors who may perform work in or around NIR sources with the potential for an over exposure.
43.4 Exceptions
Laser work is covered by the Laser Safety Program.
43.5 Roles and Responsibilities
Role Responsibilities
Division Director Ensures the NIR Program is enforced
Environment, Health & Safety (EHS) Division
Arranges or performs NIR assessment as requested or determined by an approved activity within the Work Planning and Control (WPC) system or other authorization method
Establishes controls for NIR hazards
Maintains the Berkeley Lab NIR Program
Develops and reviews substitute or alternate control measures when primary measures are infeasible or impractical
With Activity Lead, investigates all instances of suspected exposure
Supervisor/ Activity Lead
Ensures that all NIR users receive adequate and appropriate training
Ensures that all NIR users are assigned to a WPC Activity
Prepares an Activity in WPC for an NIR operation and ensures that the provisions of the Activity are properly implemented and diligently followed by users. (To complete an Activity, go to the WPC link on the Berkeley Lab A–Z listing.)
Ensures that any visitor receives a site/experimental hazard orientation as part of any visit to any NIR area https://www.lbl.gov/ehs/pub3000/CH16-quickstart.html https://www.lbl.gov/ehs/pub3000/CH16-quickstart.html https://www2.lbl.gov/ehs/pub3000/CH43.html 3/10
Investigates all instances of suspected exposure
NIR Equipment Users Receives appropriate on-the-job training (OJT) prior to unsupervised
NIR equipment use
Reads, understands, signs, and follows all procedures in the WPC Activity
Stops unsafe work activities (see PUB-3000, Chapter 1, Work Process C, Stopping Unsafe Work)
Works in a safe manner following Laboratory policy and procedural requirements
Promptly reports any malfunctions, problems, accidents, or injuries that may have an impact on safety
Immediately reports any suspected NIR exposures to the supervisor and EHS
Refers any questions or concerns to the NIR Subject Matter Expert
Important considerations for determining the full extent of safety control measures include:
Level of experience and training of individuals using the NIR equipment
Environmental factors
Personnel factors
43.6 Definitions
Term Definition
Ultraviolet (UV) Radiation
Electromagnetic radiation greater than 10 nm but less than 400 nm
Visible light Electromagnetic radiation greater than 400 nm but less than 700 nm
Infrared Radiation Electromagnetic radiation greater than 700 nm but less than 1 mm
Radio Frequency Radiation
Electromagnetic waves greater than 3 kHz but less than 300 GHz
Microwave Radiation
Electromagnetic waves greater than 300 MHz to 300 GHz (within RF frequencies)
NIR Non-ionizing Radiation (NIR) refers to electromagnetic radiation with insufficient energy to release a bound electron from an atom. NIR includes the following categories of radiation: ultraviolet (UV), visible light, infrared, radio frequency, microwave, magnetic fields, and lasers.
Electromagnetic spectrum https://www2.lbl.gov/ehs/pub3000/CH43.html 4/10
43.7 Required Work Processes
Work Process A. Non-ionizing Radiation Flowchart Work Process B. Exposure Limits Work Process C. Methods of Exposure Control Work Process D. Additional Information
Work Process A. Non-ionizing Radiation Flowchart https://www2.lbl.gov/ehs/pub3000/CH43.html 5/10
Work Process B. Exposure Limits
In accordance with 10CFR851, exposures to non-ionizing radiation must be below the limits specified in the 2016 version of Threshold Limit Values for Chemical Substances and Physical Agents, American
Conference of Governmental Industrial Hygienists (ACGIH). Because the process to determine the threshold limit value (TLV) is complex and may be adjusted for likely exposure duration, only the most common limits for conditions expected to be encountered at LBNL are listed below. The TLVs for specific applications and exposure conditions may be obtained by contacting the non-ionizing radiation subject matter expert.
https://www2.lbl.gov/ehs/pub3000/CH43.html 6/10
TLV for Sub-Radiofrequency Magnetic Fields
Frequency Range TLV Ceiling / Most Restrictive
Extremely–low-frequency (ELF) 1 Hz to 300 Hz BTLV (mT) = 60/f f in Hz
Hands and feet 1 Hz to 300 Hz BTLV (mT) = 600/f f in Hz
2 mT 20 G
Arms and legs 1 Hz to 300 Hz BTLV (mT) = 300/f f in Hz
1 mT 10 G
60 Hz 1 mT 10 G
Whole-body and partial-body 300 Hz to 30 kHz 0.2 mT 2 G
30 kHz (160 A/m) 0.2 mT 2 G
Medical electronic device wearers 0.1 mT 1 G
Point contact current 1 Hz to 2.5 kHz 1.0 mA
Point contact current 2.5 kHz to 30 kHz 0.4·f mA (f in kHz)
Light and Near-Infrared Radiation TLVs for light and near-infrared radiation apply to incoherent (non-laser) sources of visible and near-infrared radiation. These limits are based on an 8-hour exposure. The TLV is application specific and must be calculated for any broadband light source with a luminance greater than 1 candela/cm2. Contact the non-ionizing radiation subject matter expert to determine the appropriate TLV for light sources with luminance greater than 1 candela/cm2.
Magnetic Fields The TLVs for magnetic fields are divided into those limits that apply to static (DC) or (CW) magnetic fields and those that apply to sub-radiofrequency magnetic fields or alternating (AC) magnetic fields. The TLV for sub-radiofrequency magnetic fields are frequency specific.
The highest concern is for personnel who have implanted medical devices. Magnetic fields may disrupt the proper function of these devices and have catastrophic effects. This is not limited to cardiac pacemakers, but includes a wide range of devices, such as implantable cardioverter defibrillators (ICDs) and neurostimulators. The TLV in the table below is to be implemented for such devices unless specific higher values are provided in manufacturer-provided documentation.
TLV for Static Magnetic Fields
Exposure TLV
Medical Device Wearers 5 Gauss (0.5 mT) max
Whole Body (general workplace) 20,000 Gauss (2T) max
Whole Body (special worker training and controlled workplace environment) 80,000 Gauss (8T) max
Limbs 200,000 Gauss (20T) max https://www2.lbl.gov/ehs/pub3000/CH43.html 7/10
Part A - Electromagnetic FieldsA (f-frequency in MHz)
Frequency Range Power Density, S
(W/m2)
Electric Field Strength, E (V/m)
Magnetic Field Strength, H (A/m)
Averaging Time, E2, H2, or S (minutes)
30 kHz-100 kHz - 1842 163 6
100 kHz-3 MHz - 1842 16.3/f 6
1 MHz-30 MHz - 1842/f 16.3/f 6
30 MHz-100 MHz - 61.4 16.3/f 6
100 MHz-300 MHz 10 61.4 0.163 6
300 MHz-3 GHz f/30 6
3 GHz-30 GHz 100 34000/f1.079
30 GHz-300 GHz 100 68/f0.476
Radiofrequency and Microwave Radiation The TLVs for radiofrequency and microwave radiation are dependent on the frequency of the source. Limits apply to all sources from 1 Hz to 300 GHz and often include more than one limiting value, such as electric field strength (V/m), magnetic field strength (A/m), and limits on current induced within the human body (mA).
https://www2.lbl.gov/ehs/pub3000/CH43.html 8/10
A. Note that in addition to the above electromagnetic field TLVs, induced and contact radiofrequency current TLVs also apply to radiofrequency radiation from 30 kHz to 100 MHz. See the table below for commonly encountered frequencies and their respective limits. The TLVs for specific applications and exposure conditions may be obtained by contacting the non-ionizing radiation subject matter expert.
Part B – Maximum Induced and Contact Radiofrequency Currents
Maximum Current (mA)B, (f-frequency in Hz)
Frequency Range Through Both Feet Through Either Foot GraspingC Averaging Time
30 kHz-100 kHz 2000 f 1000 f 1000 f 0.2sD
100 kHz-100 MHz 200 100 100 6 minE
B. It should be noted that the current limits given above may not adequately protect against startle reaction and burns caused by transient discharges when contacting an energized object.
The ceiling value for induced and contact currents is 500 mA for no more than 15 s per 6 min period.
C. Maximum touch current is limited to 50% of the maximum grasping current.
D. I is averaged over a 0.2 s period.
E. I is averaged over a 6-minute period (e.g., for either foot or hand contact, i.e., I t<60,000 mA2-min). In this table, f is the frequency in Hz
Ultraviolet (UV) Radiation The TLVs for UV radiation apply to electromagnetic radiation with a wavelength between 180 nm and 400
nm. Such radiation may present an eye and skin hazard. These TLVs apply to UV radiation from plasma discharges (e.g., welding, plasma etchers, etc.), solar simulators, unfiltered fluorescent and incandescent lights, and other incoherent UV sources. These TLVs do not apply to UV lasers.
The TLVs for UV radiation are wavelength and time dependent. The TLVs listed in the table below are the most restrictive. Contact the non-ionizing radiation subject matter expert for an evaluation of specific UV hazards and determination of specific application TLVs if these limits cannot be met.
Incoherent UV Radiation TLVs
Duration of Exposure Per Day Effective Irradiance Eeff (mW/cm2)
8 hours 0.0001
4 hours 0.0002
2 hours 0.0004
1 hour 0.0008
30 minutes 0.0017
15 minutes 0.0033
10 minutes 0.005 https://www2.lbl.gov/ehs/pub3000/CH43.html 9/10
5 minutes 0.010
1 minutes 0.05
30 seconds 0.1
10 seconds 0.3
1 seconds 3
0.5 seconds 6
0.1 seconds 30
Work Process C. Methods of Exposure Control
Where feasible, engineering controls are used to limit exposure to non-ionizing radiation. Otherwise, administrative controls and personal protective equipment are used.
Magnetic Fields. Access must be restricted to only authorized personnel if a person’s whole body would be exposed in an area with magnetic field strength exceeding 5 Gauss. Delineating the 5 Gauss line and posting magnetic field warning signs are generally acceptable access controls.
RF & Microwave Radiation. Use Faraday cages, cables, or waveguides to contain magnetic fields.
Ultraviolet Radiation. Shield user by using polycarbonate barriers, long sleeve clothing, gloves, and face shield, as appropriate.
Work Process D. Additional Information
For assistance with NIR, contact the EHS NIR Safety Coordinator, ext. 2544.
43.8 Source Requirement Documents
10 CFR 851, Worker Safety and Health Program
C95 IEEE/ANSI Standard on Human Exposure to Radio Frequencies - Threshold Limit Values for Chemical Substances and Physical Agents, American Conference of Governmental Industrial Hygienists (ACGIH), 2016 edition
43.9 Reference Documents
Document number Title Type
07.02.003.001 Work Planning and Control Program
07.07.018.001 Laser Safety Program
https://www.lbl.gov/ehs/pub3000/CH06.html https://www.lbl.gov/ehs/pub3000/CH16.html#161 https://www2.lbl.gov/ehs/pub3000/CH43.html 10/10