11. DRAFT - JSN U0060 Electric Swivel Seated-Narrow-Isle 33' Vertical Swing Reach 3K Fork Lift.pdf

PDF 740 KB Posted

Attached to
Charleston Consolidated Storage Distribution Center
Solicitation number
Not on record
Issued by

About this file

This document contains a draft specification for an electric swivel seated narrow-aisle forklift truck and the related Special Notice for an initial outfitting project for the Charleston Consolidated Storage and Distribution Center.

The draft specification provides extensive details for a 3,000-pound capacity electric forklift, including a 48-volt electrical system, 56-inch wide carriage, 118-inch lowered mast height, 40-inch long forks, aisle lighting, safety features, manuals, required training, and more. The related Special Notice indicates that the USACE Little Rock District will post a solicitation using FAR Part 12 and 13 procedures for the initial outfitting of the Charleston Consolidated Storage and Distribution Center, with an estimated contract value between $1.5-2 million. Interested contractors are advised that the requirement will be a total small business set-aside for NAICS code 337127, the site visit is scheduled for August 23, 2022, and questions will be accepted until August 25, 2022 in advance of a September 2, 2022 estimated proposal due date and January 19, 2023 potential BOD date.

View the file

Other files

File Type Posted
25. DRAFT - Template_DHA RMF Security Control Plan_Implementation Guidance.xlsx XLSX spreadsheet
Draft Solicitation_Special Notice_Charleston CSDC.pdf PDF
0. DRAFT - SOW-FY22. IOT RD_PN89902_CSDC Charleston_2022.08.05.docx DOCX document
21. DRAFT - DHA MDE Categorization Memo.pdf PDF
27. DRAFT - Template_Information System_Incident Response Plan.docx DOCX document
24. DRAFTExample_IP Network External to Control System_Generic ICS Med-COI Boundary Diagram v4 (1).pdf PDF
2. Base Access WORKSHEET V9_Dec20_ACC (002).pdf PDF
30. DRAFT - Template-DHA-FE FRCS Vendor Risk Assessment_v2.0.docx DOCX document
22. DRAFT - DHA Privacy Impact Assessment PIA_Processes and Procedures.docx DOCX document
10. DRAFT - JB Charleston CSDC_DOR-Provided Final Furniture-Equipment Package_17Jan22.pdf PDF
18. DRAFT - DHA 27 52 33 Refrigerator Monitoring Systems.pdf PDF
33. DRAFT - Template-System Level Configuration Management Plan.doc DOC document
14. DRAFT - JBCHS IDEA FONSI-FONPA_A7 Signed (2).pdf PDF
16. DRAFT - Checklist_Control System Factory Acceptance Test and Site Acceptance Test.pdf PDF
29. DRAFT - Template-DHA RMF System Enterprise and Information Security Architecture.pdf PDF
6. DRAFT - JBC CSDC - DP2 FINAL_drawings.pdf PDF
32. DRAFT - Template-Ports-Protocols-Services Management Registry Update.xlsx XLSX spreadsheet
31. DRAFT - Template-Inventory Report-Hardware-Software.pdf PDF
28. DRAFT - Template_Program of Record_DHA Info Sys Contingency Plan.docx DOCX document
17. DRAFT - DHA 27 41 43 Audio Video Conferencing.pdf PDF
7. DRAFT - CSDC GC Schedule 30Jun22.pdf PDF
9. DRAFT - JB Charleston CSDC_Existing Inventory_ 23Mar22.pdf PDF
26. DRAFT - Template_DHA RMF System Authorization Boundary.pdf PDF
3. DRAFT - Charleston CSDC IOT Project Status Report (PSR).xlsx XLSX spreadsheet
11. DRAFT - JSN U0096 3-phase 480 VAC Powered Battery Charger For JSN U0060 Electric Forklift.pdf PDF
23. DRAFT - DHA RMF Information Flow Diagram.pdf PDF
2. Real ID TRI-Fold (15Sep20-V42).pdf PDF
13. DRAFT - JB Charleston CSDC_Program for Design_5Feb22.pdf PDF
5. DRAFT - Interiors_JBC CSDC - DP2 FINAL_drawings.pdf PDF
1. DRAFT - Drawings Installation Map - CSDS and ACC.pdf PDF
0. DRAFT FY22 IOT CSDC_Div 00_CLIN BID Schedule.xlsx XLSX spreadsheet
12. DRAFT - DHA FE Wayfinding Guidelines-Signage Standards (Draft)_01Mar22.pdf PDF
15. DRAFT - JB Charleston CSDC_Facility Site Approval.pdf PDF
8. DRAFT - JB Charleston CSDC_PRCL_v.2_21Jan21.pdf PDF
11. DRAFT - JSN U1021 Wall-MountedWireGuidanceSystemLineDriverandGuidanceControlWire-Forklift(JSN U0060).pdf PDF
19. DRAFT - DHA ACAS-NESSUS Scanning Guide-CUI.pdf PDF
20. DRAFT - DHA FRCS Baseline Categorization Memorandum-1 Oct 2020.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

This units’ specifications and the design of the Hi-bay storage racks are one system, for which each system must have the correct specifications and tolerances to work properly together.

To ensure success, the unit is designed specifically to handle Tri-wall boxes 48” W x 40” D x 45”H, weight 2800-lbs (not the 3500-lbs load as the rack has been requested to be specified) in a 72” wide very narrow aisle (VNA) and the storage racks are designed to accommodate the capacities and required clearances, hence the storage system will meet the desired function.

The wire-guided man-up turret forklift truck and the wire guidance system will have all the standard features listed on page 3 of 3 and these customized specifications to match the unit to the Hi-bay racks and wire guidance system. (a) Basic capacity is 3,000-lbs at 24” load center. (b) 48-Volt electrical system. (c) Wire guidance sensors 5.2kHz, 300ma p-p (code 515).

Provide unit with quickest charge time battery with minimum battery capacity to operate 16 hours per day (Monday-Friday) based upon weight and distance travel expectations per operational requirements. Ensure forklift battery is provided with a single point automatic watering system as described below. Forklift must interface with JSNs U0096, U1021, and U1007.

JSN U0060

(d) Carriage to be 56” wide. (e) Mast: 118” lowered mast height, 226” forklift height, operator deck height 158” (code 5371). (f) Lift-limit switch with over-ride set at 146” fork height to ensure ‘maximum overall cab/ overhead guard height’ of 168” (code 806). (g) Forks lowered to floor (code 600). (h) Forks: 40” long (code 333), (i) Aisle lighting front and rear (code 487). (j) Body Harness with tether (code 101144). (k) Fire Extinguisher (code 546). (l) Flip-up side gates with power disconnect switches (code 542). (m) Clipboard holder (code 100289). (n) Operator beverage holder (code793). (o) Travel alarm-forward & reverse (code 598). (p) UL safety label ‘E” rating (code 324). (q) Communication power hook-up (10amp) and hardware mounting bracket (code 100171). (r) Manuals: parts & operator & maintenance, English, paper copy (code 369).

o Including required power: Qty. (1) new battery: #24-125C-13, lead-acid type, to include installed single-point automatic watering system: tubing, water level indicator light, direct fill link, water container, and special hosing.

o Including: Required OSHA training class, “Safety-On-The-Move” class, one day/all day, 12 people max. All delivered, tested, and training.

Because of the agencies particular and unique loads will be stored in a specially designed hi-bay storage rack system and designed for compatibility with a specialized very narrow aisle (VNA) wire guide unit of mechanized material handling equipment, this system is unique.

Standard Features:

10 Fault Memory Flip-up sidegates and Control Arms 21” Wide Battery Compartment Fluorescent Overhead Lights 3-Wheel Suspension System Forks – 42” length Guard, Mast, Safety Glass 48-Volt Power System ‘AC’ Height Indicator 56” Width Carriage Hour Meter, Deadman Pedal Activated Active Maintenance Hour Meters – Drive, Lift, Total Miles, Key Auto Speed Reduction When Carriage ‘Not Ready’ intellidrive® control sys w/ shunt wound motor Auto Steer Centering - Guidance intellispeed® control system Banana Jack for Ground Locations Keyswitch Battery Gates, Adjustable Gates Lift Cut-Out, Lift System Relief Valve Battery Rollers Light, Warning Strobe – Amber Battery State-of-Charge w/ lift interrupt Non-skid operator’s platform Bi-directional controls Operator Position (Sit/Stand/Lean) Clear View Mast Parking Brake – Automatic Engaging Configurable Performance Parameters Power Steering Controls, Power up Run Time Diagnostics Real Time Status/Fault Code Display Cushioned Mast Stops Proportional Plugging Dual Dead-Man Pedals Paint: Raymond Red Finish w/black mast Four (4) Hour Meters: Key Hours, Dead-man Separate Lift, Travel & Steer Motors Pedal, Lift Motor, Total Distance Traveled ‘AC’ Drive and Lift and Steering Motors Simultaneous Function Control Handle Slack Chain Safety Switches W/single axis and relaxed grip Spacious Operator Compartment Status Messages and Fault Codes Storage Tote Emergency Power Disconnect Twin Tubular Mast Design Ergonomic Seat Weight Sensing On-board Forks Fall Protection System Work Lights & Overhead Fan

File details come from the government source that posted it. Updated .