6. DRAFT - JBC CSDC - DP2 FINAL_drawings.pdf

PDF 39 MB Posted

Attached to
Charleston Consolidated Storage Distribution Center Federal contract opportunity
Solicitation number
Not on record
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

This Special Notice provides information about an upcoming solicitation for an initial outfitting project at the Charleston Consolidated Storage and Distribution Center. The U.S. Army Corps of Engineers Little Rock District plans to issue a request for quote as a total small business set-aside, with a NAICS code of 337127 and size standard of 500 employees. The estimated contract value is between $1.5 million to $2 million. Interested parties may submit questions until August 25, 2022. A site visit is tentatively scheduled for August 23, 2022. The estimated proposal due date is September 2, 2022, with potential board of directors goal date of January 19, 2023 and potential option for base year goal date of March 19, 2023. This Special Notice informs potential contractors of the opportunity in advance of the solicitation.

View the file

Other files for this federal contract opportunity

Other files attached to Charleston Consolidated Storage Distribution Center, newest first.
File Type Posted
16. DRAFT - Checklist_Control System Factory Acceptance Test and Site Acceptance Test.pdf PDF
9. DRAFT - JB Charleston CSDC_Existing Inventory_ 23Mar22.pdf PDF
29. DRAFT - Template-DHA RMF System Enterprise and Information Security Architecture.pdf PDF
26. DRAFT - Template_DHA RMF System Authorization Boundary.pdf PDF
0. DRAFT - SOW-FY22. IOT RD_PN89902_CSDC Charleston_2022.08.05.docx DOCX document
23. DRAFT - DHA RMF Information Flow Diagram.pdf PDF
14. DRAFT - JBCHS IDEA FONSI-FONPA_A7 Signed (2).pdf PDF
33. DRAFT - Template-System Level Configuration Management Plan.doc DOC document
3. DRAFT - Charleston CSDC IOT Project Status Report (PSR).xlsx XLSX spreadsheet
7. DRAFT - CSDC GC Schedule 30Jun22.pdf PDF
11. DRAFT - JSN U0096 3-phase 480 VAC Powered Battery Charger For JSN U0060 Electric Forklift.pdf PDF
2. Base Access WORKSHEET V9_Dec20_ACC (002).pdf PDF
30. DRAFT - Template-DHA-FE FRCS Vendor Risk Assessment_v2.0.docx DOCX document
17. DRAFT - DHA 27 41 43 Audio Video Conferencing.pdf PDF
19. DRAFT - DHA ACAS-NESSUS Scanning Guide-CUI.pdf PDF
12. DRAFT - DHA FE Wayfinding Guidelines-Signage Standards (Draft)_01Mar22.pdf PDF
11. DRAFT - JSN U1021 Wall-MountedWireGuidanceSystemLineDriverandGuidanceControlWire-Forklift(JSN U0060).pdf PDF
5. DRAFT - Interiors_JBC CSDC - DP2 FINAL_drawings.pdf PDF
1. DRAFT - Drawings Installation Map - CSDS and ACC.pdf PDF
8. DRAFT - JB Charleston CSDC_PRCL_v.2_21Jan21.pdf PDF
20. DRAFT - DHA FRCS Baseline Categorization Memorandum-1 Oct 2020.pdf PDF
0. DRAFT FY22 IOT CSDC_Div 00_CLIN BID Schedule.xlsx XLSX spreadsheet
15. DRAFT - JB Charleston CSDC_Facility Site Approval.pdf PDF
13. DRAFT - JB Charleston CSDC_Program for Design_5Feb22.pdf PDF
Draft Solicitation_Special Notice_Charleston CSDC.pdf PDF
25. DRAFT - Template_DHA RMF Security Control Plan_Implementation Guidance.xlsx XLSX spreadsheet
31. DRAFT - Template-Inventory Report-Hardware-Software.pdf PDF
10. DRAFT - JB Charleston CSDC_DOR-Provided Final Furniture-Equipment Package_17Jan22.pdf PDF
22. DRAFT - DHA Privacy Impact Assessment PIA_Processes and Procedures.docx DOCX document
21. DRAFT - DHA MDE Categorization Memo.pdf PDF
11. DRAFT - JSN U0060 Electric Swivel Seated-Narrow-Isle 33' Vertical Swing Reach 3K Fork Lift.pdf PDF
32. DRAFT - Template-Ports-Protocols-Services Management Registry Update.xlsx XLSX spreadsheet
28. DRAFT - Template_Program of Record_DHA Info Sys Contingency Plan.docx DOCX document
2. Real ID TRI-Fold (15Sep20-V42).pdf PDF
27. DRAFT - Template_Information System_Incident Response Plan.docx DOCX document
24. DRAFTExample_IP Network External to Control System_Generic ICS Med-COI Boundary Diagram v4 (1).pdf PDF
18. DRAFT - DHA 27 52 33 Refrigerator Monitoring Systems.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1220 Marshall Street NE Minneapolis, MN 55413-1036 612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H C

A R

O

LI

N A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S O

U T

H E

A S

T

NAVAL FACILITIES

ENGINEERING COMMAND

TASK ORDER NO. :

CONTRACT NO. :

ISSUE DATE :

1220 Marshall Street NE

Minneapolis, MN 55413-1036

612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

PROJECT NUMBER :

FISCAL YEAR :

RPUID :

VICINITY MAP LOCATION MAP

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

N A

V F

A C

S E

C O

R E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

JO

IN

T B

A S

E

JB

C H

A R

LE

S

T O

N

S O

U T

H C

A R

O

LI

N A

P -9

C O

N S

O L

ID

A

T E

D S

T O

R A

G E

D

IS

T

R

IB

U T

IO

N

C E

N T

E R

JO

IN

T B

A S

E C

H A

R

LE

S T

O N

310 SOUTH 4TH AVENUE, SUITE 7050

MINNEAPOLIS, MN 55415

DAMON FARBER

ASSOCIATES, INC.

LANDSCAPE ARCHITECT

220 GRANT STREET, 7TH FLOOR

PITTSBURGH, PA 15219

LARSON DESIGN GROUP

CIVIL ENGINEER

VAA, LLC

STRUCTURAL ENGINEER

FOXFIRE PLACE

MARTINEZ, GA 30907

JAMES MADDRY, PE

FIRE PROTECTION ENGINEER

2510 NORTHWEST 31ST STREET

NEWCASTLE, OK 73065

PAULSGROVE ENGINEERING

ELECTRICAL ENGINEER

874 DIXON ROAD

COCOA, FL 73065

PAULSGROVE / TLC ENGINEERING

TELECOMMUNICATIONS ENGINEER

2300 BERKSHIRE LANE NORTH

SUITE 200

PLYMOUTH, MN 55441

P.O. BOX 1845

MT. PLEASANT, SC 29465

WHOLE BUILDING SYSTEMS, LLC

D-B PLUMBING SUBCONTRACTOR

P.O. BOX 158

FAIRFAX STATION, VA 22039

PENN CONSTRUCTION GROUP

PRE-ENGINEERED

METAL BUILDING

/9

/2

:3

:0

P M

B

IM

/J o in t

B a se C h a rl e st o n

/A

J

B C

C S

D C

.r vt

CN

C O

V E

R S

H E

E T

G-001

N69450-19-D-0910

TP JWN

SOUTHEAST DISTRICT

JOINT BASE CHARLESTON

CHARLESTON, SOUTH CAROLINA

P-9902, CONSOLIDATED STORAGE &

DISTRIBUTION CENTER

N69450-20-F-00881

N69450-19-D-0910

MARCH 15, 2021

DP-2 FINAL DESIGN SUBMITTAL

88902

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

15157466

GOOGLE 2020 GOOGLE 2020

N

TRUE

NORTH

N

TRUE

NORTH

PROJECT

SITE

AIRSIDE ACCESS

GATE

JBC MAIN GATE

AND VISITORS

CENTER

JBC SECONDARY

GATE

PROJECT

SITE

1220 Marshall Street NE Minneapolis, MN 55413-1036 612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H C

A R

O

LI

N A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S O

U T

H E

A S

T D

E P

A R

T M

E N

T O

F T

H E

N A

V Y

N A

V F

A C

S E

C O

R E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

JO

IN

T B

A S

E

JB

C H

A R

LE

S

T O

N

S O

U T

H C

A R

O

LI

N A

P -9

C O

N S

O L

ID

A

T E

D S

T O

R A

G E

D

IS

T

R

IB

U T

IO

N

C E

N T

E R

JO

IN

T B

A S

E C

H A

R

LE

S T

O N

/1

/2

:3

:5

P

M

B

IM

/J o in t

B a se C h a rl e st o n

/A

J

B C

C S

D C

.r vt

CN

S H

E E

T I

N D

E X

G-002

N69450-19-D-0910

CN JWN

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

15157467

SHEET INDEX

SHEET

NO. TITLE 35

D

D

/2

6/

D P

0% P

R E

F

IN

A L

(1 1/

/2

0)

D P

C

D

/1

7/

D P

F

IN

A

L (1

2/

/2 0)

D P

P R

E F

IN

A

L

/1 /2

D P

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/0

/2

D P

F

IN

A

L

/1 /2

PLUMBING

P-101 PLUMBING FLOOR PLAN X X X X

P-101-1 DWV PLUMBING PLAN (DP-1) X X X

P-102 LOWER WAREHOUSE SANITARY SEWER X X X

P-102-1 DWV PLUMBING PLAN (DP-1) X X X

P-301 PLUMBING SECTIONS X X X X

P-302 RESTROOM SECTIONS X X X

P-401 ENLARGED MECHANICAL ROOM X X X X

P-402 ENLARGED OFFICE AREA X X X X

P-403 PLUMBING RISERS - MECH ROOM X X X

P-404 PLUMBING RISERS - RESTROOMS X X X

P-501 PLUMBING EQUIPMENT DETAILS X X

P-502 PLUMBING EQUIPMENT DETAILS X X

P-601 PLUMBING SCHEDULES X X

MECHANICAL

M-001 HVAC NOTES AND LEGENDS X X X X

M-002 HVAC SEISMIC CRITERIA X X

M-101 HVAC FLOOR PLAN X X X X

M-301 HVAC SECTIONS X X X X

M-401 ENLARGED HVAC FLOOR PLAN OFFICE X X X X

M-402 ENLARGED HVAC FLOOR PLAN MECH ROOM X X X X

M-501 HVAC DETAILS X X X X

M-601 HVAC SCHEDULES X X X X

M-602 HVAC SCHEDULES X X X

M-701 HVAC CONTROLS MISCELLANEOUS X X X

M-702 HVAC CONTROLS AHU-1 X X X

M-703 HVAC CONTROLS AHU-2 X X X

M-704 HVAC CONTROLS CHILLED WATER SYSTEM X X

M-705 HVAC CONTROLS CHILLED WATER SYSTEM X X

M-706 HVAC CONTROLS CHILLED WATER SYSTEM X X

M-707 HVAC CONTROLS HEATING HOT WATER SYSTEM X X

M-708 HVAC CONTROLS HEATING HOT WATER SYSTEM X X

M-709 HVAC CONTROLS HEATING HOT WATER SYSTEM X X

ELECTRICAL

E-001 LEGENDS, ABBREVIATIONS AND GENERAL REQUIREMENTS X X X X

ES100 ELECTRICAL SITE PLAN X X X X

EG101 GROUNDING PLAN X X X

EG102 LIGHTING PROTECTION PLAN X X X

EL111 OVERALL LIGHTING PLAN X X X

EL112 LIGHTING PLAN - AREA A X X X X

EL113 LIGHTING PLAN - AREA B X X X X

EL114 LIGHTING PLAN - AREA C X X X X

EL115 LIGHTING PLAN - AREA D X X X X

EL116 LIGHTING PLAN - AREA E X X X X

EL117 LIGHTING PLAN - AREA F X X X X

EP110 UNDERFLOOR PLAN X X X

EP111 EQUIPMENT POWER PLAN - AREA A X X X X

EP112 EQUIPMENT POWER PLAN - AREA B X X X X

EP113 EQUIPMENT POWER PLAN - AREA C X X X X

EP114 EQUIPMENT POWER PLAN - AREA D X X X X

EP115 EQUIPMENT POWER PLAN - AREA E X X X X

EP116 EQUIPMENT POWER PLAN - AREA F X X X X

EP121 RECEPTACLE PLAN - AREA A X X X X

EP122 RECEPTACLE PLAN - AREA B X X X X

EP123 RECEPTACLE PLAN - AREA C X X X X

EP124 RECEPTACLE PLAN - AREA D X X X X

EP125 RECEPTACLE PLAN - AREA E X X X X

EP126 RECEPTACLE PLAN - AREA F X X X X

E-200 EXTERIOR BUILDING ELEVATIONS X X X

E-400 ENLARGED PLANS X X X

E-501 SITE DETAILS X X X

E-502 SITE DETAILS X X X

E-503 SITE LIGHTING DETAILS X X X

E-510 ELECTRICAL DETAILS X X X

E-530 LIGHTING DETAILS X X X

E-550 GROUNDING DETAILS X X X

E-551 LIGHTNING PROTECTION AND GROUNDING DETAILS X X X

E-601 SINGLE-LINE DIAGRAM X X X X

E-701 PANELBOARD SCHEDULES X X X

E-702 PANELBOARD SCHEDULES X X X

E-703 PANELBOARD SCHEDULES X X X

E-704 PANELBOARD SCHEDULES X X X

E-705 PANELBOARD SCHEDULES X X

E-720 EQUIPMENT CONNECTION SCHEDULES X X X

E-730 LIGHT FIXTURE SCHEDULES X X X

E-801 LIGHTING DIAGRAMS - SHEET 1 X X X

E-802 LIGHTING DIAGRAMS - SHEET 2 X X X

E-803 LIGHTING DIAGRAMS - SHEET 3 X X X

TELECOMMUNICATIONS

T-001 TECHNOLOGY LEGEND X X X X

T-002 TECHNOLOGY GENERAL NOTES X X X X

T-101 LEVEL 1 - OVERALL TELECOMMUNICATIONS VOICE-DATA PLAN X X X X

T-101A LEVEL 1 - OVERALL TELECOMMUNICATIONS VOICE-DATA PLAN - AREA A X X X X

T-101B LEVEL 1 - OVERALL TELECOMMUNICATIONS VOICE-DATA PLAN - AREA B X X X X

T-101C LEVEL 1 - OVERALL TELECOMMUNICATIONS VOICE-DATA PLAN - AREA C X X X X

T-101D LEVEL 1 - OVERALL TELECOMMUNICATIONS VOICE-DATA PLAN - AREA D X X X X

T-101E LEVEL 1 - OVERALL TELECOMMUNICATIONS VOICE-DATA PLAN - AREA E X X X X

T-101F LEVEL 1 - OVERALL TELECOMMUNICATIONS VOICE-DATA PLAN - AREA F X X X X

T-102 LEVEL 1 - OVERALL TELECOMMUNICATIONS AV - SECURITY PLAN X X X X

T-102A LEVEL 1 - OVERALL TELECOMMUNICATIONS AV - SECURITY PLAN - AREA A X X X X

T-102B LEVEL 1 - OVERALL TELECOMMUNICATIONS AV - SECURITY PLAN - AREA B X X X X

T-102C LEVEL 1 - OVERALL TELECOMMUNICATIONS AV - SECURITY PLAN - AREA C X X X X

T-102D LEVEL 1 - OVERALL TELECOMMUNICATIONS AV - SECURITY PLAN - AREA D X X X X

T-102E LEVEL 1 - OVERALL TELECOMMUNICATIONS AV - SECURITY PLAN - AREA E X X X X

T-102F LEVEL 1 - OVERALL TELECOMMUNICATIONS AV - SECURITY PLAN - AREA F X X X X

T-201 TECHNOLOGY ELEVATIONS X X X

T-202 TECHNOLOGY ELEVATIONS X X

T-401 TECHNOLOGY ENLARGED PLANS X X X X

T-501 TECHNOLOGY DETAILS X X X X

T-502 TECHNOLOGY DETAILS X X X

T-503 TECHNOLOGY DETAILS X X X

T-504 TECHNOLOGY DETAILS X X X

T-505 TECHNOLOGY DETAILS X X X

T-506 TECHNOLOGY DETAILS X X X

T-601 TECHNOLOGY SCHEDULES X X X

T-602 TECHNOLOGY DIAGRAMS X X

T-603 TECHNOLOGY DIAGRAMS X X

SHEET INDEX

SHEET

NO. TITLE 35

D

D

/2

6/

D P

0% P

R E

F

IN

A L

(1 1/

/2

0)

D P

C

D

/1

7/

D P

F

IN

A

L (1

2/

/2 0)

D P

P R

E F

IN

A

L

/1 /2

D P

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/0

/2

D P

F

IN

A

L

/1 /2

ST314 CROSS SECTION AT LINE 1-5 (4'-0" CANOPY) X X

ST315 WALL FRAMING ELEVATION AT LINE 5 (LOW BAY) X X

ST316 WALL FRAMING ELEVATION AT LINE J (LOW WALL) X X

ST317 WALL FRAMING ELEVATION AT LINE 25 (LOW BAY) X X

ST318 WALL FRAMING ELEVATION AT LINE A (LOW BAY) X X

ST319 WALL FRAMING ELEVATION AT LINE A (HIGH BAY) X X

ST320 WALL FRAMING ELEVATION AT LINE (HIGH BAY) X X

ST321 WALL FRAMING ELEVATION AT LINE J (HIGH BAY) X X

ST322 WALL FRAMING ELEVATION AT LINE (HIGH BAY) X X

ST501 GENERAL DETAILS X X X

ST502 GENERAL DETAILS X X X

ST503 GENERAL DETAILS X X X

ST504 GENERAL DETAILS X X X

ST505 GENERAL DETAILS X X X

ST506 ANCHOR BOLT DETAILS X X X

ST507 WALL FRAMING DETAILS X X X

ST508 WALL FRAMING DETAILS X X X

ST509 WALL FRAMING DETAILS X X X

ST510 WALL FRAMING DETAILS X X X

ST511 WALL FRAMING DETAILS X X X

ST512 PANEL DETAILS X X X

ST513 PANEL DETAILS X X X

ST514 PANEL DETAILS X X X

ST515 PANEL DETAILS X X X

ST516 PANEL DETAILS X X X

ST517 PANEL DETAILS X X

ST518 PANEL DETAILS X X

ARCHITECTURAL

A-001 ABBREVIATIONS AND SYMBOLS X X X X X X X

A-101 FLOOR PLAN (DP1) - OVERALL X X X X

A-101A FLOOR PLAN (DP1) - AREA A X X X X

A-101B FLOOR PLAN (DP1) - AREA B X X X X

A-101C FLOOR PLAN (DP1) - AREA C X X X X

A-101D FLOOR PLAN (DP1) - AREA D X X X X

A-101E FLOOR PLAN (DP1) - AREA E X X X X

A-101F FLOOR PLAN (DP1) - AREA F X X X X

A-111 FLOOR PLAN (DP2) - OVERALL X X X

A-111A FLOOR PLAN (DP2) - AREA A X X X

A-111B FLOOR PLAN (DP2) - AREA B X X X

A-111C FLOOR PLAN (DP2) - AREA C X X X

A-111D FLOOR PLAN (DP2) - AREA D X X X

A-111E FLOOR PLAN (DP2) - AREA E X X X

A-111F FLOOR PLAN (DP2) - AREA F X X X

A-112 REFLECTED CEILING PLAN - OVERALL X X X X

A-112A REFLECTED CEILING PLAN - AREA A X X X X

A-112B REFLECTED CEILING PLAN - AREA B X X X X

A-201 EXTERIOR ELEVATIONS X X X X

A-202 ENLARGED EXTERIOR ELEVATIONS X X X X

A-203 ENLARGED EXTERIOR ELEVATIONS X X X

A-204 ENLARGED EXTERIOR ELEVATIONS X X X

A-205 ENLARGED EXTERIOR ELEVATIONS X X X

A-206 ENLARGED EXTERIOR ELEVATION X X X

A-301 BUILDING SECTIONS X X X X

A-302 WALL SECTIONS X X X X

A-303 WALL SECTIONS X X X

A-310 WALL SECTIONS - INTERIOR AND INTERIOR FINISHES X X X

A-400 TOILET ACCESSORY ELEVATIONS AND DETAILS X X X

A-401 ENLARGED PLANS AND ELEVATIONS X X X

A-410 ENLARGED FLOOR PLAN (DP-1) X X

A-501 EXTERIOR DETAILS - SITE X X X

A-510 EXTERIOR DETAILS - WALL X X X

A-511 EXTERIOR DETAILS - DOOR/WINDOW X X X

A-512 EXTERIOR DETAILS - DOOR/WINDOW X X X

A-520 DP1 INTERIOR SCHEDULES AND TYPES X X X

A-521 DP1 INTERIOR DETAILS X X X

A-531 INTERIOR DETAIL - DOOR/WINDOW X X X

A-540 PARTITION TYPES, DOOR TYPES, AND DOOR SCHEDULE X X X X

A-541 INTERIOR DETAILS - PARTITION X X X

A-542 INTERIOR DETAILS - CEILING AND FLOOR X X X

A-550 INTERIOR DETAILS X X X

A-553 INTERIOR DETAILS - CASEWORK X X X

A-800 AIR BARRIER SYSTEM PLAN - OVERALL X X X

A-801 AIR BARRIER SYSTEM SECTIONS X X X

INTERIORS

I-001 ARCHITECTURAL FINISH KEY & ROOM FINISH SCHEDULE X X X X

I-101A FINISH PLAN - AREA A X X

I-101B FINISH PLAN - AREA B X X

I-200 SIGNAGE KEY X X X X

I-201A SIGNAGE PLAN - AREA A X X

I-201B SIGNAGE PLAN - AREA B X X

I-201C SIGNAGE PLAN - AREA C X X

I-201D SIGNAGE PLAN - AREA D X X

I-201E SIGNAGE PLAN - AREA E X X

I-201F SIGNAGE PLAN - AREA F X X

IF101 FURNITURE PLAN - FOR REFERENCE ONLY X X X X

FIRE ALARM

FA - 1 PROJECT COVER PAGE X

FA - 2 FLOOR PLAN SECTION A X

FA - 3 FLOOR PLAN SECTION B X

FA - 4 FLOOR PLAN SECTION C X

FA - 5 FLOOR PLAN SECTION D X

FA - 6 FLOOR PLAN SECTION E X

FA - 7 FLOOR PLAN SECTION F X

FA - 8 CALCULATIONS X

FA - 9 CALCULATIONS X

FA - 10 CALCULATIONS X

FA - 11 PARTIAL RISER X

FA - 12 PARTIAL RISER X

FIRE PROTECTION

FP-1 FIRE PROTECTION SITE PLAN X X

FP-2 GENERAL NOTES AND DETAILS X X X

FP-3 FIRE PROTECTION PIPING PLAN X X X

FP-4 FIRE PROTECTION PIPING PLAN X X

FP-5 FIRE PROTECTION PIPING PLAN X X

FP-6 FIRE PROTECTION PIPING PLAN X X

FP-7 FIRE PROTECTION PIPING PLAN X X

FP-8 FIRE PROTECTION PIPING PLAN X X

FP-9 FIRE PROTECTION PIPING PLAN X X

SHEET INDEX

SHEET

NO. TITLE 35

D

D

/2

6/

D P

0% P

R E

F

IN

A L

(1 1/

/2

0)

D P

C

D

/1

7/

D P

F

IN

A

L (1

2/

/2 0)

D P

P R

E F

IN

A

L

/1 /2

D P

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

/0

/2

D P

F

IN

A

L

/1 /2

GENERAL

G-001 COVER SHEET X X X X

G-001A COVER SHEET X X X

G-002 SHEET INDEX X X X X X X X

G-100 CODE PLAN X X X X X X X

G-101 PARTIAL LIFE SAFETY PLAN X X X X X X X

G-102 PARTIAL LIFE SAFETY PLAN X X X X X X X

G-103 SITE CODE PLAN X X X X X X X

SURVEY

VF101 EXISTING CONDITIONS PLAN X X X X

CIVIL

CD101 SITE DEMOLITION PLAN X X X X

C-001 GENERAL SITE AND UTILITY NOTES X X X X

C-101 GENERAL AND EROSION AND SEDIMENT CONTROL NOTES X X X X

C-501 EROSION AND SEDIMENT CONTROL DETAILS X X X X

C-502 EROSION AND SEDIMENT CONTROL DETAILS X X X X

C-503 EROSION & SEDIMENT CONTROL DETAILS X X X X

CG101 SITE GRADING AND DRAINAGE PLAN X X X X

CG102 INITIAL LAND DISTURBANCE PHASE 1 - EROSION & SEDIMENT CONTROL PLAN X X X

CG103 STABILIZATION PHASE 2 - EROSION & SEDIMENT CONTROL PLAN X X X

CG201 STORM PROFILES X X X

CH101 HORIZONTAL CONTROL PLAN X X X

CS101 SITE LAYOUT PLAN X X X X

CS501 SITE DETAILS X X X X

CS502 SITE DETAILS X X X X

CS503 ENLARGED SITE LAYOUT, GRADING, AND UTILITY PLAN DETAILS X X

CU101 SITE UTILITY PLAN X X X X

CU201 UTILITY PROFILES X X X

CU501 SITE WATER DETAILS X X X X

CU502 SITE WATER DETAILS X X X X

CU503 SITE SANITARY DETAILS X X X X

LANDSCAPE

L-001 LANDSCAPE NOTES AND SYMBOLS X X X X

L-100 TREE MITIGATION PLAN X X

L-101 OVERALL LANDSCAPE PLAN X X X X

L-101A ENLARGED LANDSCAPE PLAN - AREA A X X X X

L-101B ENLARGED LANDSCAPE PLAN - AREA B X X X X

L-501 LANDSCAPE DETAILS X X X X

STRUCTURAL

S-001 GENERAL STRUCTURAL NOTES X X X X

S-002 SPECIAL INSPECTIONS SCHEDULE X X X

S-101 FOUNDATION PLAN - OVERALL X X X X

S-101A FOUNDATION PLAN - AREA A X X X X

S-101B FOUNDATION PLAN - AREA B X X X X

S-101C FOUNDATION PLAN - AREA C X X X X

S-101D FOUNDATION PLAN - AREA D X X X X

S-101E FOUNDATION PLAN - AREA E X X X X

S-101F FOUNDATION PLAN - AREA F X X X X

S-401 ENLARGED PLANS X X X

S-501 FOUNDATION DETAILS X X X X

S-502 FOUNDATION DETAILS X X X X

S-503 FOUNDATION DETAILS X X X X

S-504 CONCRETE VAULT AND COOLER DETAILS X X X

S-531 TYPICAL MASONRY DETAILS X X X X

S-601 SCHEDULES X X X X

PEMB

ST001 COVER SHEET X X X

ST002 BUILDING INFO SHEET X X X

ST003 BUILDING INFO SHEET X X X

ST101 ANCHOR BOLT PLAN - WEST X X X

ST102 ANCHOR BOLT PLAN - EAST X X X

ST103 ROOF FRAMING PLAN WEST (LOW BAY) X X X

ST104 ROOF FRAMING PLAN EAST (LOW BAY) X X X

ST105 ROOF FRAMING PLAN (HIGH BAY) X X

ST106 ROOF FRAMING PLAN (13'-9" CANOPY) X X

ST107 ROOF FRAMING PLAN (6'-2" CANOPY) X X

ST108 ROOF FRAMING PLAN (4'-0" CANOPY) X X

ST109 SOFFIT FRAMING PLAN (13'-9" CANOPY) X X

ST110 SOFFIT FRAMING PLAN (6'-2" CANOPY) X X

ST111 SOFFIT FRAMING PLAN (4'-0") X X

ST112 ROOF BRACING PLAN WEST (LOW BAY) X X

ST113 ROOF BRACING PLAN EAST (LOW BAY) X X

ST114 ROOF BRACING PLAN (HIGH BAY) X X

ST115 ROOF BRACING PLAN (13'-9" CANOPY) X X

ST116 ROOF BRACING PLAN (6'-2" CANOPY) X X

ST117 ROOF BRACING PLAN (4'-0" CANOPY) X X

ST118 ROOF WIND BRACING PLAN WEST (LOW BAY) X X

ST119 ROOF WIND BRACING PLAN EAST (LOW BAY) X X

ST120 ROOF WIND BRACING PLAN (HIGH BAY) X X

ST121 ROOF SHEETING PLAN WEST (LOW BAY) X X

ST122 ROOF SHEETING PLAN EAST (LOW BAY) X X

ST123 ROOF SHEETING PLAN (HIGH BAY) X X

ST124 ROOF SHEETING PLAN (13'-9" CANOPY) X X

ST125 ROOF SHEETING PLAN (6'-2" CANOPY) X X

ST126 ROOF SHEETING PLAN (4'-0" CANOPY) X X

ST127 SOFFIT SHEETING PLAN (13'-9" CANOPY) X X

ST128 SOFFIT SHEETING PLAN (6'-2" CANOPY) X X

ST129 SOFFIT SHEETING PLAN (4'-0" CANOPY) X X

ST201 WALL SHEETING ELEVATION AT LINE 5 (LOW BAY) X X X

ST202 WALL SHEETING ELEVATION AT LINE J (LOW BAY) X X X

ST203 WALL SHEETING ELEVATION AT LINE 25 (LOW BAY) X X

ST204 WALL SHEETING ELEVATION AT LINE A (LOW BAY) X X

ST205 WALL SHEETING ELEVATION AT LINE A (HIGH BAY) X X

ST206 WALL SHEETING ELEVATION AT LINE 1 (HIGH BAY) X X

ST207 WALL SHEETING ELEVATION AT LINE J (HIGH BAY) X X

ST208 WALL SHEETING ELEVATION AT LINE 5 (HIGH BAY) X X

ST301 CROSS SECTION AT LINE 5 (LOW BAY) X X X

ST302 CROSS SECTION AT LINE 7,11,13,17,19,21,23 X X X

ST303 CROSS SECTION AT LINE 25 (LOW BAY) X X X

ST304 CROSS SECTION AT LINE A (HIGH BAY) X X X

ST305 CROSS SECTION AT LINE C & G (HIGH BAY) X X X

ST306 CROSS SECTION AT LINE E (HIGH BAY) X X

ST307 CROSS SECTION AT LINE J (HIGH BAY) X X

ST308 CROSS SECTION AT LINE 6,8,15 (LOW BAY) X X

ST309 CROSS SECTION AT LINE 12,18,22 (LOW BAY) X X

ST310 CROSS SECTION AT LINE 20,24 (LOW BAY) X X

ST311 CROSS SECTION AT LINE SW WIND COLUMNS (HIGH BAY) X X

ST312 CROSS SECTION AT LINE 14 & 16 (13'-9" CANOPY) X X

ST313 CROSS SECTION AT LINE 8,10 (6'-2" CANOPY) X X

1. APPLICABLE CODES AND STANDARDS

ABBREVIATIONS TITLE EDITION

IBC INTERNATIONAL BUILDING CODE 2018

IMC INTERNATIONAL MECHANICAL CODE 2018

IPC INTERNATIONAL PLUMBING CODE 2018

NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2019

NFPA 70 NATIONAL ELECTRICAL CODE 2017

NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2019

NFPA 80 STANDARD FOR FIRE DOOR AND OTHER OPENING

PROTECTIVES

NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND

VENTILATING SYSTEMS

NFPA 101 LIFE SAFETY CODE 2018

UFC 1-200-01 GENERAL BUILDING REQUIREMENTS 8 OCT 2019

UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES CHANGE 4,

7 FEB 2020

UFC 4-010-01 DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS 12 DEC 2018

UFC 4-021-01 DESIGN AND O&M; MASS NOTIFICATION SYSTEMS CHANGE 1

JAN 2010

2. TYPE OF CONSTRUCTION (IBC 601)

BUILDING ELEMENT

TYPE OF

CONSTRUCTION

FIRE RESISTANCE

RATING

PRIMARY STRUCTURAL FRAME IIB 0 HR

BEARING EXTERIOR WALL IIB 0 HR

BEARING INTERIOR WALL IIB 0 HR *

NON-BEARING EXTERIOR WALL IIB IBC TABLE 602

NON-BEARING INTERIOR WALL IIB 0 HR *

FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS

AND JOISTS

IIB 0 HR

ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS

AND JOISTS

IIB 0 HR

* EXCEPT AS REQUIRED FOR OCCUPANCY SEPARATION, INCIDENTAL USE, AND OTHER PASSIVE

FIRE PROTECTION.

3. CLASSIFICATION OF OCCUPANCY - MIXED WITHOUT SEPARATION

AREAS* OCCUPANCY IBC NFPA 101

MECH./ELEC. EQUIPMENT ROOMS INCIDENTAL T509 N/A

OFFICES, PANTRY BREAKROOM BUSINESS, GROUP B 304.1 6.1.11

WAREHOUSE, STORAGE ROOMS STORAGE, GROUP S-1 304.11 6.1.13

5. MODIFIED ALLOWABLE HEIGHT (IBC 504)

OCCUPANCY CONSTRUCTION TYPE MODIFIED ALLOWABLE HEIGHT (FT / STORY)

S-1 IBC IIA, NFPA TYPE II(111) 75 / 3

4. BUILDING ALLOWABLE AREA - NONSEPARATED (IBC 506.2)

FLOOR /

USE

TABLE 506.2 (SF)

ACTUAL

RESTRICTING

OCCUPANCY

BUSINESS ACCESSORY 50.7.1.1 2,352

6. INCIDENTAL USE AND OTHER PASSIVE FIRE PROTECTION

AREA REQUIRED RATING CODE

BOILER/MECH. ROOM 0 HR SMOKE PARTITON

WITH SPRINKLERS

IBC TABLE 509,

NFPA 101 - 8.7.1.2

7. BUILDING SEPARATION (IBC TABLE 602)

OCCUPANCY ELEVATION

RESTRICTIVE FIRE

SEPARATION

DISTANCE (FT)

FIRE RESISTIVE

RATING OF

EXTERIOR WALL

S-1 NORTH/SOUTH/WEST/EAST > 30 NO RATING

8. OPENING PROTECTION FOR FIRE AND SMOKE RESISTIVE CONSTRUCTION

COMPONENT

FIRE DOOR

DUCT PENETRATIONS

OTHER

PENETRATIONS

NFPA 101

TABLE 8.3.3.2.2

/NFPA 90

1 HR FIRE BARRIER 3/4 HR 1-1/2 HR FIRE DAMPER ONLY ON

TRANSFER DUCTS IN H OCCUPANCIES

1 HR NFPA 101 TABLE

8.3.3.2.2 /NFPA 90

5.3

9. OCCUPANT LOAD SUMMARY (UFC 3-600 -01 10.3 NFPA 101 TABLE 7.3.1.2)

ROOMS AREA (SF)

OL FACTOR

SF / PERSON

OCCUPANT

LOAD

(PERSONS)

001,002,003,009,011,014A,016,018,020,021,022 87,459 500 175

BUILDING 94,475 260

11. OCCUPANT LOAD SUMMARY AND MINIMUM EXITS FROM FLOOR

AREA GROSS AREA (SF) OCCUPANTS

REQUIRED EXITS

(NFPA 101)

REQUIRED EXIT SEPARATION

(NFPA 101 7.5.1.3.3)

DIAGONAL /

DIAGONAL / PROVIDED

STORAGE 94,475 260 2 (7.4.1.2) 515' / 171.6' / 199'

12. COMMON PATH, DEAD-END, AND TRAVEL DISTANCE LIMITS (NFPA 101, TABLE A7.6)

OCCUPANCY COMMON PATH LIMIT (FT) DEAD END LIMIT (FT) TRAVEL DISTANCE LIMIT (FT)

BUSINESS 100 50 300

STORAGE 100 100 400

13. MINIMUM EGRESS WIDTHS

COMPONENT REQUIREMENT WIDTH (IN) NFPA 101

DOORS IN EGRESS ACCESS PER COMPONENT 32 SECTION 7.2.1.2.3.2

CORRIDOR SERVING 50 OR MORE OCCUPANTS MINIMUM 44 SECTION 7.3

CORRIDOR SERVING LESS THAN 50 OCCUPANTS MINIMUM 36

OTHER LEVEL EGRESS COMPONENTS PER PERSON 0.2 TABLE 7.3.3.1

16. MINIMUM INTERIOR FINISH RATINGS (NFPA, TABLE A.10.2.2)

OCCUPANCY EXITS

EXIT ACCESS

CORRIDORS

OTHER SPACES

BUSINESS CLASS A. B OR C CLASS A OR B CLASS A, B OR C

STORAGE

17. FIRE SUPPRESSION REQUIREMENTS (UFC 3-600-01 9-7.2, 9-10, 9-17)

SPRINKLERS STANDPIPE FIRE EXTINGUISHERS

SPRINKLERS PROVIDED

THROUGHOUT THE BUILDING

NOT REQUIRED NOT REQUIRED

PER NFPA 101-42.3.5

18. FIRE ALARM REQUIREMENTS (UFC 3-600-01, 9-18)

MANUAL INITIATION AUTOMATIC INITIATION OCCUPANT NOTIFICATION

MANUAL FIRE ALARM PULL

STATIONS PROVIDED AT EXITS

FLOW AND TAMPER SWITCHES,

SPOT SMOKE DETECTORS AT

ALARM PANELS AND DUCT SMOKE

DETECTORS PROVIDED

VOICE MESSAGING, WHITE FIRE

ALARM/MASS NOTIFICATION

STROBES

19. SMOKE MANAGEMENT SYSTEMS

SMOKE CONTROL SYSTEM SMOKE AND HEAT VENTS PASSIVE SMOKE MANAGEMENT

NOT REQUIRED NOT REQUIRED SMOKE PARTITIONS WHERE

NOTED

ASSEMBLY

STORAGE

ACCESSORY 507.1.1 617

STORAGE

UNLIMITED PER 507.4 87,459

TOTAL

10. EXIT CAPACITY

FLOOR COMPONENT FACTOR

OCCUPANT

LOAD

TOTAL WIDTH

REQUIRED/PROVIDED

LEVEL 1 LEVEL 0.2" / PERSON 260 52" / 256"

SLOPED EGRESS COMPONENTS PER PERSON 0.3 TABLE 7.3.3.1

94,475

FC 1-300-09N NAVY AND MARINE CORPS DESIGN PROCEDURES CHANGE 4

14 JUN 2018

NOTE: AREA INCREASE IS NOT REQUIRED.

OFFICES / SHOPS 1 HR SEPARATION FROM

WAREHOUSE

UFC 3-600-01-4-44.5.2

USE

STORAGE

010, 015, 019,023 2,495 500 5EQUIP. SPACES

006,008 617 15 41BREAK, CONF. ROOM

004,005,007,012,013,018 2352 150 24OFFICES

CLASS A. B OR C CLASS A, B OR C CLASS A, B OR C

BMET ROOOM INDUSTRIAL, GROUP F-1 306.2 6.1.12

017 194 300 1IT EQUIPMENT

014 1.358 100 14INDUSTRIAL

INDUSTRIAL 100 50 250

INDUSTRIAL ACCESSORY 507.1.1 1,358

SECTION 7.3

NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY

FIRE PUMPS

NFPA 22 STANDARD FOR WATER TANKS FOR FIRE PROTECTION 2018

NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE

FIRE MAINS AND THEIR APPURTENANCES

1220 Marshall Street NE

Minneapolis, MN 55413-1036

612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR.

NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H

C

A R

O L

I N

A

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

S

O U

T H

E A

S T

D E

P A

R T

M E

T

F

T

H E

A V

Y

N A

V F

C

C

O R

E

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

N A

S

J A

C K

S O

N V

I L

L E

F

O

R I D

A

P

C

O N

S O

L I D

A T

O

R A

G

I S

T R

I B

U T

I O

N

C

E N

T E

R

J O

I N

T

B

A S

E

C

H A

R L

E S

T O

N

JMM

N69450-19-D-0910

JMM JMM

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

G-100

C O

P

L A

N

15157468

AutoCAD SHX Text

8/10/2020 3:13:36 PM

AutoCAD SHX Text BIM 360://Joint Base Charleston/A20_JBC CSDC.rvt

W

1 5 7 132 6 8 10 12 14 16

9 15

M A

TC

H

LI

N

E A

1/ G

-1

M A

TC

H

LI

N

E A

1/ G

-1

TD = 203'

32"

13"

E-2

E-7

5.8"

32"

E-1

6.0"

32"

E-3

5.8"

32"

E-6

5.8"

32"

CPT = 66'

TD = 142'

CPT = 27'

TD = 80'

LOADING DOCK

WALK-IN COOLER

VAULT

OFFICE

OFFICE

CONFERENCE

OPEN OFFICE

PANTRY & BREAK

FILE

JANITOR

WOMEN

MEN

BMET

HAZMAT

014A

ELECTRICAL

STORAGE ROOM

CER

HIGH BAY

STORAGE

WAREHOUSE

ELECTRICAL

ROOM

ELEC.

TD = 211'

FACP

EGRESS TRAVEL PATH

EXIT SIGN

SMOKE RESISTANT PARTITION

DIRECTION AL EXIT SIGN

1-HOUR FIRE WALL

DE

CPT

TD

DENOTES DEAD END

DENOTES COMMON PATH

DENOTES TRAVEL DISTANCE

ROOM USE / OCCUPANCY

BUSINESS

24 PERSONS

MECH. / ELEC. / BUILDING

EQUIPMENT

5 PERSONS

STORAGE

175 PERSONS

TOTAL FLOOR = 260 PERSONS

LIFE SAFETY LEGEND

FOR LIFE SAFETY CODE SUMMARY, SEE SHEET G-100

DENOTES EGRESS PATH START

DENOTES END OF COMMON PATH

ASSEMBLY

41 PERSONS

OCCUPANT LOAD USING EXIT

XXX

XXX

XXX

REQUIRED EXIT WIDTH (INCHES)

PROVIDED EXIT WIDTH (INCHES)

E-1 DENOTES EXIT NUMBER

IT EQUIPMENT

1 PERSONS

INDUSTRIAL

14 PERSONS

1220 Marshall Street NE

Minneapolis, MN 55413-1036

612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR.

NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H

C

A R

O L

I N

A

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

U

T H

E A

S T

D E

P A

R T

M E

T

V

Y

N A

V F

C

O R

E

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

N A

S

J A

C K

S O

N V

I L

L E

F

O

R I D

A

P

C

O N

S O

L I D

A T

O

R A

S

T R

I B

U T

I O

N

C

E N

T E

R

J O

I N

T

B

A S

E

C

H A

R L

E S

T O

N

JMM

N69450-19-D-0910

JMM JMM

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

G-101

TRUE

NORTH

PLAN

NORTH

1/16" = 1'-0"

A1

PARTIAL LIFE SAFETY PLAN

2'

4'

8' 24'

SCALE 1/16"=1'-0"

16' 48'

P A

R T

I A

L

L

I F

E

S

A F

E T

Y

P

L A

N

15157469

AutoCAD SHX Text

8/10/2020 3:13:36 PM

E

G

J

17 19 21 23 2514 16 18 20 22 24

D

F

H

M A

TC

H

LI

N

E A

1/ G

-1

M A

TC

H

LI

N

E A

1/ G

-1

TD = 150'

CPT = TD = 58'

TD = 250'

TD = 273'

E-3

5.8"

32"

E-4

5.8"

32"

E-5

5.8"

32"

E-6

5.8"

32"

ELECTRICAL

ROOM

CER

LUMS

MECHANICAL

ROOM

WAREHOUSE

NITROGEN &

OXYGEN

STORAGE

SPRINKLER

RISERS

FACP

EGRESS TRAVEL PATH

EXIT SIGN

SMOKE RESISTANT PARTITION

DIRECTION AL EXIT SIGN

1-HOUR FIRE WALL

DE

CPT

TD

DENOTES DEAD END

DENOTES COMMON PATH

DENOTES TRAVEL DISTANCE

ROOM USE / OCCUPANCY

BUSINESS

24 PERSONS

MECH. / ELEC. / BUILDING

EQUIPMENT

5 PERSONS

STORAGE

175 PERSONS

TOTAL FLOOR = 260 PERSONS

LIFE SAFETY LEGEND

FOR LIFE SAFETY CODE SUMMARY, SEE SHEET G-100

DENOTES EGRESS PATH START

DENOTES END OF COMMON PATH

ASSEMBLY

41 PERSONS

OCCUPANT LOAD USING EXIT

XXX

XXX

XXX

REQUIRED EXIT WIDTH (INCHES)

PROVIDED EXIT WIDTH (INCHES)

E-1 DENOTES EXIT NUMBER

IT EQUIPMENT

1 PERSONS

INDUSTRIAL

14 PERSONS

1220 Marshall Street NE

Minneapolis, MN 55413-1036

612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR.

NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H

C

A R

O L

I N

A

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

U

T H

E A

S T

D E

P A

R T

M E

T

V

Y

N A

V F

C

O R

E

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

N A

S

J A

C K

S O

N V

I L

L E

F

O

R I D

A

P

C

O N

S O

L I D

A T

O

R A

S

T R

I B

U T

I O

N

C

E N

T E

R

J O

I N

T

B

A S

E

C

H A

R L

E S

T O

N

JMM

N69450-19-D-0910

JMM JMM

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

G-102

1/16" = 1'-0"

A1

PARTIAL LIFE SAFETY PLAN

TRUE

NORTH

PLAN

NORTH

2'

4'

8' 24'

SCALE 1/16"=1'-0"

16' 48'

P A

R T

I A

L

L

I F

E

S

A F

E T

Y

P

L A

N

15157470

AutoCAD SHX Text

8/10/2020 3:13:36 PM

X

X

X

X

X

X

X

X

X

X

X

X

X

XX

X

X

X

X

X X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X co

JOINT BASE CHARLESTON

1220 Marshall Street NE

Minneapolis, MN 55413-1036

612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

I P

T I O

N D

A T

E A

P P

R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR.

NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H

C

A R

O L

I N

A

N A

V A

L

F

A C

I L I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

U

T H

E A

S T

D E

P A

R T

M E

T

V

Y

N A

V F

C

O R

E

N A

V A

L

F

A C

I L

I T

I E

S

E

N G

I N

E E

R I N

G

C

O M

M A

N D

N A

S

J A

C K

S O

N V

I L

L E

F

O

R I D

A

P

C

O N

S O

L I D

A T

O

R A

S

T R

I B

U T

I O

N

C

E N

T E

R

J O

I N

T

B

A S

E

C

H A

R L

E S

T O

N

JMM

N69450-19-D-0910

JMM JMM

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

G-103

S I T

E

C

O D

E

P

L A

N

TRUE

NORTH

PLAN

NORTH

1" = 30'-0"

A3

SITE CODE PLAN

15157471

AutoCAD SHX Text 210-6\

AutoCAD SHX Text

AutoCAD SHX Text 42-3\

AutoCAD SHX Text

AutoCAD SHX Text 132-1

AutoCAD SHX Text

AutoCAD SHX Text 150-10

AutoCAD SHX Text

AutoCAD SHX Text 3-6\

AutoCAD SHX Text

AutoCAD SHX Text 241-3

AutoCAD SHX Text

AutoCAD SHX Text 411-9\

AutoCAD SHX Text

AutoCAD SHX Text 57-1\

AutoCAD SHX Text

AutoCAD SHX Text 31-3

AutoCAD SHX Text

AutoCAD SHX Text 12-3\

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING CITY WATER MAIN

AutoCAD SHX Text

PROPOSED 4" CL52 DI. STORAGE TANK FILL PIPE

AutoCAD SHX Text

EXISTING HYDRANT 3010 STATIC = 63 PSI RESIDUAL = 44 PSI

AutoCAD SHX Text

EXISTING HYDRANT 3009 FLOW = 935 GPM

AutoCAD SHX Text

PURPOSED FIRE HYDRANT

AutoCAD SHX Text

8" CL52 DI FIRE PUMP DISCHARGE TO BUILDING

AutoCAD SHX Text

14' X 20' FIRE BUILDING

AutoCAD SHX Text

10" CL52 DI TANK DISCHARGE TO FIRE PUMP

AutoCAD SHX Text

30' X 25' HIGH 70,000 GALLON FIRE WATER STORAGE TANKS

AutoCAD SHX Text

PROPOSED 8" FIRE LINE CL52 DI. UNDERGROUND

AutoCAD SHX Text

FIRE PUMP INLET

AutoCAD SHX Text

STORAGE TANK FILL PIPE

AutoCAD SHX Text 5-8\

AutoCAD SHX Text

AutoCAD SHX Text 39-2

AutoCAD SHX Text

AutoCAD SHX Text

PURPOSED F.D.C

AutoCAD SHX Text 56-2

AutoCAD SHX Text

AutoCAD SHX Text 17-5\

AutoCAD SHX Text

AutoCAD SHX Text 8-9\

AutoCAD SHX Text

AutoCAD SHX Text 44-11

AutoCAD SHX Text

AutoCAD SHX Text 8-0

AutoCAD SHX Text

AutoCAD SHX Text 7-8

AutoCAD SHX Text

AutoCAD SHX Text 11-4

AutoCAD SHX Text

AutoCAD SHX Text 8-0

AutoCAD SHX Text

AutoCAD SHX Text 8-0

AutoCAD SHX Text

AutoCAD SHX Text 11-4

AutoCAD SHX Text

AutoCAD SHX Text 11-4

AutoCAD SHX Text

AutoCAD SHX Text 13-0

AutoCAD SHX Text

AutoCAD SHX Text

PURPOSED FIRE HYDRANT

AutoCAD SHX Text

TO SUPPLY FIRE RISERS INSIDE THE BUILDING

AutoCAD SHX Text

8" CL52 DI. FIRE FLOW METER DISCHARGE TO STORAGE TANK

AutoCAD SHX Text 43-1\

AutoCAD SHX Text

AutoCAD SHX Text 45-0\

AutoCAD SHX Text

AutoCAD SHX Text

PURPOSED FIRE HYDRANT

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

UG1

AutoCAD SHX Text

8/10/2020 3:13:36 PM

A-123

DRAWING ABBREVIATIONS

A ---------------------

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AB ANCHOR BOLT

ACC ACCESSIBLE

ACM ALUMINUM COMPOSITE MATERIAL

ACS AUTOMATIC CONTROL SYSTEM

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADMIN ADMINISTRATION

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGGR AGGREGATE

AHU AIR HANDLING UNIT

AIB AIR INFILTRATION BARRIER

AL ALUMINUM

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZE

APC ACOUSTICAL PANEL CEILING

APPROX APPROXIMATE

AR AS REQUIRED

ARCD ARMY RESERVE CAREER DEVELOPMENT

ARCH ARCHITECT

ASC ABOVE SUSPENDED CEILING

ASSY ASSEMBLY

ATC ACOUSTICAL TILE CEILING

ATFP ANTI-TERRORISM FORCE PROTECTION

AVG AVERAGE

AW ARCHITECTURAL WOODWORK

AWP ACOUSTICAL WALL PANEL

AWT ACOUSTICAL WALL TREATMENT

B ---------------------

B LABEL CLASS B DOOR

BKGRD BACKGROUND

BALC BALCONY

BATT BATTERY

BB BULLETIN BOARD

BC BOOKCASE

BD BOARD

BDRY BOUNDARY

BFF BELOW FINISH FLOOR

BHMA BUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATION

BIT BITUMEN

BLDG BUILDING

BLKG BLOCKING

BLT IN BUILT-IN

BN BULLNOSE

BOD BASIS OF DESIGN

BOS BOTTOM OF STEEL

BOT BOTTOM

BP BUILDING PAPER

BRK BRICK

BRKT BRACKET

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT-UP ROOFING

C ---------------------

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

CAB CABINET

CATW CATWALK

CAV CAVITY

CBB CEMENTITIOUS (BACKER) BOARD

CCD COUNTER COILING DOOR

CD CONSTRUCTION DOCUMENTS

CDW CHILLED DRINKING WATER

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR

INSTALLED

CFE CONTRACTOR FURNISHED EQUIPMENT

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CI CAST IRON

CIP CAST-IN-PLACE

CIRC CIRCULATION

CJ CONTROL JOINT

CL CENTER LINE / COMPOSITE LUMBER

CLG CEILING

CLG DIFF CEILING DIFFUSER

CLG HT CEILING HEIGHT

CLL COLUMN LINE

CLO CLOSET

CLR COLOR

CLRM CLASSROOM

CMT CEMENT BOARD

CMU CONCRETE MASONRY UNIT

CNDS CONDENSATE

CDR CARD READER

CO CLEANOUT / COMPANY (ROOM NAME)

COL COLUMN

COW CENTER ON WALL

COMM COMMUNICATION

CONC CONCRETE

CONC FLR CONCRETE FLOOR

CONF CONFERENCE

CONT CONTINUE

COORD COORDINATE

CORR CORRIDOR

CP CONCRETE PIPE

CPT CARPET

CR CONTROL ROOM / COAT RACK

CS CAST STONE

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTL CONTROLLED

CTF CERAMIC TILE FLOOR

CTR CENTER

CU FT CUBIC FEET

CW CASEMENT WINDOW

D ---------------------

D DEPTH

D LABEL CLASS D DOOR

DBL DOUBLE

DC DISPLAY CASE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DIA DIAMETER

DIR DIRECTION

DIST DISTANCE / DISTRIBUTION

DIV DIVISION

DOC DOCUMENT

DR DOOR

DS DOWNSPOUT

DTL DETAIL

E ---------------------

E LABEL CLASS E DOOR

EA EACH

EF EACH FACE/

ENTRANCE FACILITY

EIFS EXTERIOR INSULATION AND FINISH

SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

ENTR ENTRANCE

EPS EXPANDED POLYSTYRENE BOARD

(INSULATION)

EQ EQUAL

ES EACH SIDE

ESS EXTERIOR SUN SHADE

EWC ELECTRIC WATER COOLER

EXIST EXISTING

EXP EXPOSED

EXT EXTERIOR

EXT EXTINGUISHER

EXT GR EXTERIOR GRADE

F ---------------------

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FAC FACILITY

FAM FAMILY

FAS BD FASCIA BOARD

FC BRK FACE BRICK

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FED FEDERAL

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF INSUL FOIL BACKED INSULATION

FGL FIBERGLASS

FH FIRE HOSE

FHP FULL HEIGHT PARTITION

FIN FINISH

FIN BS FINISH BOTH SIDES

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIXT FIXTURE

FLAM FLAMMABLE

FLASH FLASHING

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLMT FLUSH MOUNT

FLR FLOOR

FM FACTORY MUTUAL

FOC FACE OF CONCRETE

FOM FACE OF MASONRY

FR FIRE RESISTANT

FRG FIBER REINFORCED GYPSUM

FRMG FRAMING

FRP FIBERGLASS REINFORCED PLASTIC

FRTW FIRE RETARDANT TREATED WOOD

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET

FTG FOOTING

FWC FABRIC WALLCOVERING

G ---------------------

G NATURAL GAS

GALV GALVANIZED

GB GRAB BAR

GFCI GOVERNMENT FURNISHED CONTRACTOR

INSTALLED

GFGI GOVERNMENT INSTALLED FURNISHED

INSTALLED BY GOVERNMENT

GFRG GLASS-FIBER-REINFORCED GYPSUM

GLZ GLAZING

GR FL GROUND FLOOR

GT GROUT

GUT GUTTER

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H ---------------------

HB HOSE BIBB

HDPE HIGH DENSITY POLYETHYLENE

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR

(FILTER)

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HPC HIGH PERFORMANCE COATING

HORIZ HORIZONTAL

HT HEIGHT

HYDR HYDRAULIC

I ---------------------

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION / INSULATED

INT INTERIOR

ILO IN LIEU OF

J ---------------------

JAN JANITOR

K ---------------------

KPD KEYPAD

KIT KITCHEN

KPL KICKPLATE

L ---------------------

LAC LACTATION

LAM LAMINATE

LAV LAVATORY

LBR LUMBER

LBS POUND

LDG LANDING

LF LINEAR FEET (FOOT)

LIB LIBRARY

LIN LINEAR

LK LOCKER

LOC LOCATION

LT LIGHT

LVDR LOUVER DOOR

LVR LOUVER

M ---------------------

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MATL MATERIAL

MAT WALK-OFF MAT

MAX MAXIMUM

MB MARKER BOARD

MC MOISTURE CONTENT

MD METAL DECK

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MEMB MEMBRANE

MF MILL FINISH

MFR MANUFACTURER

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM, MINUTE

MIRR MIRROR

MISC MISCELLANEOUS

MLDG MOLDING (MOULDING)

MO MASONRY OPENING

MOD MODIFY / MODIFIED

MP MILITARY POLICE

MRP METAL ROOF PANEL

MB MOISTURE BARRIER

MTG MOUNTING

MTL METAL

MVBL MOVABLE

MWL METAL WALL LOUVER

MWP METAL WALL PANEL

N ---------------------

N NORTH

NA NOT APPLICABLE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NP NO PAINT

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

O -------------------

OA OVERALL

OC ON CENTER

OCC OCCUPANT(S)

OCD OVERHEAD COILING DOOR

OD OUTSIDE DIAMETER

OFD OVERFLOW DRAIN

OFF OFFICE

OGL OBSCURE GLASS

OH OVERHEAD SECTIONAL DOOR

OLF OCCUPANT LOAD FACTOR

OMS ORGANIZATIONAL MAINTENANCE SHOP

OPH OPPOSITE HAND

OPNG OPENING

OP OPERABLE PARTITION

OPP OPPOSITE

OPQ OPAQUE

OWSJ OPEN WEB STEEL JOIST

OPR OPERABLE

ORD OVERFLOW ROOF DRAIN

ORIG ORIGINAL

P --------------------

PA PUBLIC ADDRESS

PAR PARAPET

PAT PATTERN

PB PULL BOX Z

PBD PARTICLEBOARD

PCC PRECAST CONCRETE

PCF POUNDS PER CUBIC FOOT

PCT PERCENT

PERF PERFORATED

PERIM PERIMETER

PH PHASE

PIL PILASTER

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLG PILING

PLYWD PLYWOOD

PNL PANEL

PNT PAINT

PP PL PUSH/PULL PLATE

PR PAIR

PRCST PRECAST

PRKG PARKING

PS CONC PRESTRESSED CONCRETE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTDR PAPER TOWEL DISPENSER AND

RECEPTACLE

PTN PARTITION

PWR POWER

Q --------------------

QT QUARRY TILE

QTB QUARRY TILE BASE

QTY QUANTITY

R --------------------

RB RUBBER BASE

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REINFORCED CONCRETE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RDG INS RIGID INSULATION, SOLID

REC RECESSED

REC ROOM RECREATION ROOM

REF REFERENCE

REM REMOVABLE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RES RESINOUS COATING / RESINOUS FLOORING

RESIL RESILIENT

REST RESTROOM

RET RETENTION

RF RUBBER FLOORING

RFG ROOFING

RH ROOF HATCH

RHR RIGHT HAND REVERSE

RL ROOF LEADER

RLG RAILING

RM ROOM

RO ROUGH OPENING

RSD ROLLING STEEL DOOR

RV ROOF VENT

RVL REVEAL

S --------------------

SB SPLASH BLOCK

SC SEALED CONCRETE

SCHED SCHEDULE

SD SMOKE DETECTOR / SOAP DISPENSER

SDT STATIC DISSIPATIVE TILE

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGL SINGLE

SH SHOWER HOOK

SHT MTL SHEET METAL (FLASHING)

SHTHG SHEATHING

SHSD RECESSED SOAP HOLDER

SHS SHOWER SEAT

SHV SHELVING

SIM SIMILAR / SIMULATOR

SIGN SIGNAGE

SJ SCORED JOINT

SKLT SKYLIGHT

SLNT SEALANT

SM SHEET METAL

SMK SMOKE

SMLS SEAMLESS

SND SANITARY NAPKIN HOLDER

SNW SANITARY NAPKIN WASTE DISPOSAL

SP EL SPOT ELEVATION

SPEC SPECIFICATION

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SSM SOLID SURFACE MATERIAL

SSMR STANDING SEAM METAL ROOF

SST STAINLESS STEEL

ST STAIN

STD STANDARD

STL JST STEEL JOIST

STL RF DK STEEL ROOF DECK

STOR STORAGE

STR STRINGERS

STRB/HRN STROBE/HORN

SUB FL SUBFLOOR

SUP SUPPLY

SV SHEET VINYL

SW SIDEWALK

T --------------------

T TREAD

T/S TUB/SHOWER

TB TACK BOARD

TC TERRA COTTA

TD TRENCH DRAIN

TEL TELEPHONE

TEMP TEMPORARY

TER TERRAZZO /

TELECOMMUNICATIONS EQUIPMENT ROOM

TFF TOP OF FINISH FLOOR

THK THICKNESS

TK BD TACKBOARD

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TOF TOP OF FOOTING

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOPO TOPOGRAPHY

TOS TOP OF SLAB

TP TOILET PARTITION

TPD TOILET TISSUE DISPENSER

TR TELECOMMUNICATIONS ROOM

TRANS TRANSOM

TRTD TREATED

TV TELEVISION

TWP TRANSLUCENT WALL PANEL

U --------------------

UGND UNDERGROUND

UH UNIT HEATER / UTILITY HOOK

UL UNDERWRITERS LABORATORIES

UNEX UNEXCAVATED

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UR URINAL

US UTILITY SHELF

UTIL UTILITY

UV UNIT VENTILATOR

V --------------------

VEST VESTIBULE

VER VERIFY

VIF VERIFY IN FIELD

W --------------------

W/ WITH

WB WINDOW BLIND / SHADE / WEATHER

BARRIER

WD WOOD

WEAP WEAPONS

WG WALL GUARD / CRASH RAIL

WH WALL HYDRANT

W/O WITHOUT

A-123

A

EL=120'-0"

JOIST BEARING

A3A

A-123

OFFICE

A-123

A-123

4 2

X

DETAIL TAG

DETAIL NUMBER

SHEET NUMBER

DETAIL SECTION

DETAIL NUMBER

SHEET NUMBER

SECTION TAG

SECTION NUMBER

SHEET NUMBER

ELEVATION TAG

ELEVATION NUMBER

SHEET NUMBER

INTERIOR ELEVATION TAG

ELEVATION NUMBER

SHEET NUMBER

ROOM TAG

ROOM NAME

ROOM NUMBER

WINDOW TYPE TAG

GRID LINE AND TAG

SPOT ELEVATION

KEYNOTE

DOOR NUMBER

PARTITION TYPE / TAG

NEW WALL / PARTITION

SYMBOLS LEGEND

BRICK

MATERIALS LEGEND

CMU

CONCRETE

SAND OR GROUT

GRANULAR FILL

EARTH

STEEL

PLYWOOD

GYP BD

GYPSUM SHEATHING

CEMENTITIOUS BACKER UNIT

STUCCO

SOLID SURFACE

WOOD, FINISH CARPENTRY

WOOD BLOCKING

RIGID INSULATION

SPRAY-APPLIED INSULATION

BATT INSULATION

FOR DP2 DRAWINGS:

DP2 ELEMENT

DP1 ELEMENT (HALF-

TONE), REFERENCE

DP1 SHEETS FOR

INFORMATION

1220 Marshall Street NE Minneapolis, MN 55413-1036 612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H C

A R

O

LI

N A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S O

U T

H E

A S

T D

E P

A R

T M

E N

T O

F T

H E

N A

V Y

N A

V F

A C

S E

C O

R E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

JO

IN

T B

A S

E

JB

C H

A R

LE

S

T O

N

S O

U T

H C

A R

O

LI

N A

P -9

C O

N S

O L

ID

A

T E

D S

T O

R A

G E

D

IS

T

R

IB

U T

IO

N

C E

N T

E R

JO

IN

T B

A S

E C

H A

R

LE

S T

O N

/9

/2

:4

:1

P M

B

IM

/J o in t

B a se C h a rl e st o n

/A

J

B C

C S

D C

.r vt

CN

A B

B R

E V

IA

T

IO

N

S A

N D

S Y

M B

O L S

A-001

N69450-19-D-0910

TP JWN

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

15157602

A

C

E

G

J

1 5 7 13 17 19 21 23 252 6 8 10 12 14 16 18 20 22 24

D

F

H

9 15

/REFER TO 1 A-111D

/REFER TO 1 A-111C

/REFER TO 1 A-111E/REFER TO 1 A-111F

/REFER TO 1 A-111B/REFER TO 1 A-111A

476' - 8"

26' - 5" 26' - 5"26' - 5"26' - 5" 26' - 5"

16' - 4" 16' - 0" 20' - 6" 26' - 5" 26' - 5" 25' - 8" 20' - 8" 32' - 11" 26' - 5" 24' - 8" 9' - 5" 18' - 9" 26' - 5" 26' - 5" 26' - 5" 26' - 5" 26' - 5" 26' - 5" 26' - 5" 27' - 7"

PALLETS = 23

STORAGE

ROOM

BMET

HAZMAT

014A

CER

LUMS

FILE

JANITOR

OPEN OFFICE

CONFERENCE

OFFICE

WALK-IN COOLER

PANTRY & BREAK

WAREHOUSE

NITROGEN &

OXYGEN

STORAGE

MECHANICAL

ROOM

ELECTRICAL

ROOM

ELEC.

WOMEN

MEN

VAULT

LOADING DOCK

HIGH BAY

STORAGE

OFFICE

ELECTRICAL

ROOM

B

1220 Marshall Street NE Minneapolis, MN 55413-1036 612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H C

A R

O

LI

N A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S O

U T

H E

A S

T D

E P

A R

T M

E N

T O

F T

H E

N A

V Y

N A

V F

A C

S E

C O

R E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

JO

IN

T B

A S

E

JB

C H

A R

LE

S

T O

N

S O

U T

H C

A R

O

LI

N A

P -9

C O

N S

O L

ID

A

T E

D S

T O

R A

G E

D

IS

T

R

IB

U T

IO

N

C E

N T

E R

JO

IN

T B

A S

E C

H A

R

LE

S T

O N

/1

/2

:5

:4

P

M

B

IM

/J o in t

B a se C h a rl e st o n

/A

J

B C

C S

D C

.r vt

CN

F L O

O R

P L A

N

D P

O

V E

R A

L L

A-111

N69450-19-D-0910

TP JWN

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

15157610

N

PROJECT

NORTH

0 8' 16' 32' 48'

N

TRUE

NORTH

B

F

CA

E D

KEYPLAN

GENERAL NOTES - FLOOR PLAN

A. THESE GENERAL NOTES APPLY TO BOTH DP1 AND DP2 DRAWING

PACKAGES. FLOOR PLANS SHOWING DP1 INFORMATION ARE ON

SHEETS A101A - A101F. FLOOR PLANS SHOWING DP2 INFORMATION

ARE ON SHEETS A111A - A111F.

B. PLAN DIMENSIONS LOCATING EXTERIOR WALL SYSTEMS ARE TO:

1. INTERIOR FACE OF CMU BACK-UP AT EXTERIOR WALLS UNO

2. EXTERIOR FACE OF MASONRY VENEER / CAVITY WALLS UNO

C. PLAN DIMENSIONS LOCATING STRUCTURAL ELEMENTS ARE TO

CENTERLINE OF COLUMNS AND BEAMS UNO

D. PLAN DIMENSIONS LOCATING DOOR OPENINGS IN EXTERIOR WALL

SYSTEMS ARE MASONRY OPENINGS

E. PLAN DIMENSIONS LOCATING INTERIOR WALL SYSTEMS ARE TO:

A. FACE OF GYPSUM BOARD UNO

B. CENTERLINE OF STRUCTURAL GRID UNO

C. FACE OF CMU

F. DOOR FRAMES LOCATED 4" FROM PERPENDICULAR WALL UNO

G. KEYNOTES WITHOUT ARROWS APPLY TO THE ENTIRE ROOM

H. FOR LIFE SAFETY PLANS, SEE SHEETS G101-G103

I. FOR PARTITION TYPES, SEE SHEET A-520 FOR MASONRY PARTITION

TYPES (DP1) AND SHEET A-540 FOR STEEL STUD PARTITION TYPES

(DP2)

J. FINISH FLOOR ELEVATION 100'-0" CORRESPONDS TO ELEVATIONS

INDICATED ON SHEET S-101

K. FOR FINISH KEYS, SEE SHEET A-520 (DP1) AND SHEET I-001.

L. FOR ROOM FINISH SCHEDULE, SEE SHEET I-001.

M. ALL INTERIOR STUD WALLS WHICH INTERSECT EXTERIOR PEMB

WALL ASSEMBLY, PROVIDE (2) PEMB VERT GIRT MEMBERS TO CLOSE

OFF THE GAP BETWEEN HOIZ GIRTS. VERT GIRTS TO ALIGN WITH THE

FACE OF PERPENDICULAR STUD WALL. STUD FRAMING AND GYP BD

SHALL BE TERMINATED TO THE INTERIOR SIDE OF GIRTS AND

PROVIDE MOVEMENT/EXPANSION JOINT PER PEMB REQUIREMENTS

(DEEP LEG TRACK/ETC).

N. FOR ARCHITECTURAL SITE ELEMENTS, SEE SHEET A-501. (DP-1)

O. FOR FURRING AT EXTERIOR WALL, ALIGN FACE OF STUD WITH

INTERIOR FACE OF PEMB CHANNEL.

3/64" = 1'-0"A-111

FLOOR PLAN - OVERALL1

A

C

E

1 5 72 6 8 10

D

/REFER TO 1 A-101F

R

E F

E R

-1

B

6' - 2"

CLEAR

29' - 10"

CLEAR

33' - 3"

TYP

C L E

A R

F2

1J6

B6A

B6A

B6

B6A

A6

B6A

B6A

F2

F2

F2

F2

A-201

F2F2

F2

16' - 4" 16' - 0" 20' - 6" 26' - 5" 26' - 5" 25' - 8" 20' - 8" 6' - 6"

LOADING DOCK

HIGH BAY

STORAGE

WALK-IN COOLER

VAULT

WAREHOUSE

OPEN OFFICE

PANTRY & BREAK

WOMEN

012 MEN

JANITOR

FILE

ELEC.

CONFERENCE

OFFICE

OFFICE

A-303

A-303

A-310

F2

B6

A-401

ALIGN

1J6

1J6

A-550

A-550

A-550

A-401

ALIGN

A-550

REV

A-550

ALIGN

12' - 6"

A-531

F3

A L

IG

N

A-542

A-542

A-542

33 TYP

TYP

A-531

A-553

11" 4' - 0"

FDFD

T/WALL

10'-0"

AFF

EQ EQ

6' - 0" 4' - 0" 4' - 0" 6' - 0" 4' - 0" 4' - 0"

B

1220 Marshall Street NE Minneapolis, MN 55413-1036 612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H C

A R

O

LI

N A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S O

U T

H E

A S

T D

E P

A R

T M

E N

T O

F T

H E

N A

V Y

N A

V F

A C

S E

C O

R E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

JO

IN

T B

A S

E

JB

C H

A R

LE

S

T O

N

S O

U T

H C

A R

O

LI

N A

P -9

C O

N S

O L

ID

A

T E

D S

T O

R A

G E

D

IS

T

R

IB

U T

IO

N

C E

N T

E R

JO

IN

T B

A S

E C

H A

R

LE

S T

O N

/9

/2

:3

:0

P M

B

IM

/J o in t

B a se C h a rl e st o n

/A

J

B C

C S

D C

.r vt

CN

F L O

O R

P L A

N

D P

A

R E

A A

A-111A

N69450-19-D-0910

TP JWN

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

15157611

1/8" = 1'-0"A-111A

FLOOR PLAN (DP2) - AREA A1

N

PROJECT

NORTH

N

TRUE

NORTH

0 4' 8' 16'

B

F

CA

E D

KEYPLAN

KEYNOTE - FLOOR PLAN

KEYNOTE DESCRIPTION

1 STOOP

2 BOLLARD

3 CONCRETE SPLASH BLOCK AT DOWNSPOUT.

COORDINATE WITH CIVIL/LANDSCAPE

4 PEMB STRUCTURE

8 MOTORIZED DOCK DOORS, DOCK BUMPERS, SEALS

AND Z-GUARDS

9 CONCRETE VAULT WALL

10 EXTENT OF DEPRESSED SLAB FOR WALK-IN COOLER

11 GENERATOR TEST PAD

12 CHILLER SLAB

17 MOTORIZED DOCK LEVELER

18 LOADING DOCK SAFETY GATE

30 SEE IF101 FOR GFGI FURNITURE

31 GUARD BUMPERS

32 PALLETS- GFGI (SHOWN FOR REFERENCE ONLY)

33 FIXED TRI-WALL PALLET RACK, 9'W 4'D 15'H

34 FIXED TRI-WALL PALLET RACK, 5'W 4'D 15'H

35 EMERGENCY EYE WASH/SHOWER

36 ELECTRIC WATER COOLER (DUAL HT) SEE - 2/A-400

37 PARTITION TYPE 1A6 ON TOP OF CMU WALL

38 PARTITION TYPE A6 ON TOP OF CMU WALL

39 REFRIGERATOR, GFGI

40 CHARGING RACKS - GFGI (SHOWN FOR REFERENCE

ONLY)

42 ELECTRICAL FORKLIFT CHARGING AND STAGING

AREA. PAINT 4" DIAGONAL STRIPES, SAFETY YELLOW.

43 ELECTRICAL FORKLIFT CHARGING STATION (GFGI)

44 BMET WORK AREA - LARGE EQUIPMENT GFGI

45 FLOOR SCRUBBER CHARGING STATION (GFGI)

46 5'-0" PEDESTRIAN SAFETY AISLE, PAINT 4" DIAGONAL

STRIPES, SAFETY YELLOW

47 TV, GFGI- SEE 4/A-550 FOR BLOCKING RQMTS

48 SHELVING STORAGE UNIT - SEE 6/A-553

49 FLOOR SINK

50 UTILITY SINK

GENERAL NOTES - FLOOR PLAN

A. THESE GENERAL NOTES APPLY TO BOTH DP1 AND DP2 DRAWING

PACKAGES. FLOOR PLANS SHOWING DP1 INFORMATION ARE ON

SHEETS A101A - A101F. FLOOR PLANS SHOWING DP2 INFORMATION

ARE ON SHEETS A111A - A111F.

B. PLAN DIMENSIONS LOCATING EXTERIOR WALL SYSTEMS ARE TO:

1. INTERIOR FACE OF CMU BACK-UP AT EXTERIOR WALLS UNO

2. EXTERIOR FACE OF MASONRY VENEER / CAVITY WALLS UNO

C. PLAN DIMENSIONS LOCATING STRUCTURAL ELEMENTS ARE TO

CENTERLINE OF COLUMNS AND BEAMS UNO

D. PLAN DIMENSIONS LOCATING DOOR OPENINGS IN EXTERIOR WALL

SYSTEMS ARE MASONRY OPENINGS

E. PLAN DIMENSIONS LOCATING INTERIOR WALL SYSTEMS ARE TO:

A. FACE OF GYPSUM BOARD UNO

B. CENTERLINE OF STRUCTURAL GRID UNO

C. FACE OF CMU

F. DOOR FRAMES LOCATED 4" FROM PERPENDICULAR WALL UNO

G. KEYNOTES WITHOUT ARROWS APPLY TO THE ENTIRE ROOM

H. FOR LIFE SAFETY PLANS, SEE SHEETS G101-G103

I. FOR PARTITION TYPES, SEE SHEET A-520 FOR MASONRY PARTITION

TYPES (DP1) AND SHEET A-540 FOR STEEL STUD PARTITION TYPES

(DP2)

J. FINISH FLOOR ELEVATION 100'-0" CORRESPONDS TO ELEVATIONS

INDICATED ON SHEET S-101

K. FOR FINISH KEYS, SEE SHEET A-520 (DP1) AND SHEET I-001.

L. FOR ROOM FINISH SCHEDULE, SEE SHEET I-001.

M. ALL INTERIOR STUD WALLS WHICH INTERSECT EXTERIOR PEMB

WALL ASSEMBLY, PROVIDE (2) PEMB VERT GIRT MEMBERS TO CLOSE

OFF THE GAP BETWEEN HOIZ GIRTS. VERT GIRTS TO ALIGN WITH THE

FACE OF PERPENDICULAR STUD WALL. STUD FRAMING AND GYP BD

SHALL BE TERMINATED TO THE INTERIOR SIDE OF GIRTS AND

PROVIDE MOVEMENT/EXPANSION JOINT PER PEMB REQUIREMENTS

(DEEP LEG TRACK/ETC).

N. FOR ARCHITECTURAL SITE ELEMENTS, SEE SHEET A-501. (DP-1)

O. FOR FURRING AT EXTERIOR WALL, ALIGN FACE OF STUD WITH

INTERIOR FACE OF PEMB CHANNEL.

E

13 17 1912 14 16 18 20

D

R

E F

E R

-1

A

R

E F

E R

-1

C

/REFER TO 1 A-101E /REFER TO 1 A-101E

CLEAR

33' - 3"

CLEAR

33' - 3"

26' - 5" 24' - 8" 9' - 5" 18' - 9" 26' - 5" 26' - 5" 26' - 5"

C L E

A R

A6

1A61A6

1A6

1A6

1A6

1A6

A6

A6

8' - 0"

TYP

A L

IG

N

1A6

A

014A

BMET

HAZMAT

014A

ELECTRICAL

ROOM

STORAGE

ROOM

CER

LUMS

MECHANICAL

ROOM

NITROGEN &

OXYGEN

STORAGE

WAREHOUSE

A-310

7' - 8"

4' - 1"

EQ EQ

4' - 1"

ALIGN

ALIGN

1' - 8" 3' - 10"C L E

A R

A6A

F2

1A6

A-550

FCO

FD

FD

FCO

FD

FCO

FCO

A L

IG

N

A L

IG

N

A-310

C L E

A R

A-541

11' - 0" 5' - 0"

ALIGN

B

A-541

A-541

20' - 5"

1220 Marshall Street NE Minneapolis, MN 55413-1036 612.677.7100

612.677.7499 fax www.rsparch.com

RSP Architects, Ltd.

1 2 3 4 5

D

C

B

A

1 2 3 4 5

D

C

B

A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

APPROVED

FOR COMMANDER NAVFAC / B.L.T.L.

ACTIVITY

SATISFACTORY TO DATE

DES DRW CHK

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

A/E

INFO

SEAL

EPROJECT

NO.:

SCALE:

PWD SHEET

NUMBER

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

AS SHOWN

S O

U T

H C

A R

O

LI

N A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

S O

U T

H E

A S

T D

E P

A R

T M

E N

T O

F T

H E

N A

V Y

N A

V F

A C

S E

C O

R E

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

JO

IN

T B

A S

E

JB

C H

A R

LE

S

T O

N

S O

U T

H C

A R

O

LI

N A

P -9

C O

N S

O L

ID

A

T E

D S

T O

R A

G E

D

IS

T

R

IB

U T

IO

N

C E

N T

E R

JO

IN

T B

A S

E C

H A

R

LE

S T

O N

/1

/2

:1

:5

P

M

B

IM

/J o in t

B a se C h a rl e st o n

/A

J

B C

C S

D C

.r vt

CN

F L O

O R

P L A

N

D P

A

R E

A B

A-111B

N69450-19-D-0910

TP JWN

DP-2 FINAL DESIGN SUBMITTAL

MARCH 15, 2021

15157612

1/8" = 1'-0"A-111B

FLOOR PLAN (DP2) - AREA B1

GENERAL NOTES - FLOOR PLAN

A. THESE GENERAL NOTES APPLY TO BOTH DP1 AND DP2 DRAWING

PACKAGES. FLOOR PLANS SHOWING DP1 INFORMATION ARE ON

SHEETS A101A - A101F. FLOOR PLANS SHOWING DP2 INFORMATION

ARE ON SHEETS A111A - A111F.

B. PLAN DIMENSIONS LOCATING EXTERIOR WALL SYSTEMS ARE TO:

1. INTERIOR FACE OF CMU BACK-UP AT EXTERIOR WALLS UNO

2. EXTERIOR FACE OF MASONRY VENEER / CAVITY WALLS UNO

C. PLAN DIMENSIONS LOCATING STRUCTURAL ELEMENTS ARE TO

CENTERLINE OF COLUMNS AND BEAMS UNO

D. PLAN DIMENSIONS LOCATING DOOR OPENINGS IN EXTERIOR WALL

SYSTEMS ARE MASONRY OPENINGS

E. PLAN DIMENSIONS LOCATING INTERIOR WALL SYSTEMS ARE TO:

A. FACE OF GYPSUM BOARD UNO

B. CENTERLINE OF STRUCTURAL GRID UNO

C. FACE OF CMU

F. DOOR FRAMES LOCATED 4" FROM PERPENDICULAR WALL UNO

G. KEYNOTES WITHOUT ARROWS APPLY TO THE ENTIRE ROOM

H. FOR LIFE SAFETY PLANS, SEE SHEETS G101-G103

I. FOR PARTITION TYPES, SEE SHEET A-520 FOR MASONRY PARTITION

TYPES (DP1) AND SHEET A-540 FOR STEEL STUD PARTITION TYPES

(DP2)

J. FINISH FLOOR ELEVATION 100'-0" CORRESPONDS TO ELEVATIONS

INDICATED ON SHEET S-101

K. FOR FINISH KEYS, SEE SHEET A-520 (DP1) AND SHEET I-001.

L. FOR ROOM FINISH SCHEDULE, SEE SHEET I-001.

M. ALL INTERIOR STUD WALLS WHICH INTERSECT EXTERIOR PEMB

WALL ASSEMBLY, PROVIDE (2) PEMB VERT GIRT MEMBERS TO CLOSE

OFF THE GAP BETWEEN HOIZ GIRTS. VERT GIRTS TO ALIGN WITH THE

FACE OF PERPENDICULAR STUD WALL. STUD FRAMING AND GYP BD

SHALL BE TERMINATED TO THE INTERIOR SIDE OF GIRTS AND

PROVIDE MOVEMENT/EXPANSION JOINT PER PEMB REQUIREMENTS

(DEEP LEG TRACK/ETC).

N. FOR ARCHITECTURAL SITE ELEMENTS, SEE SHEET A-501. (DP-1)

O. FOR FURRING AT EXTERIOR WALL, ALIGN FACE OF STUD WITH

INTERIOR FACE OF PEMB CHANNEL.

KEYNOTE - FLOOR PLAN

KEYNOTE DESCRIPTION

1 STOOP

2 BOLLARD

3 CONCRETE SPLASH BLOCK AT DOWNSPOUT.

COORDINATE WITH CIVIL/LANDSCAPE

4 PEMB STRUCTURE

8 MOTORIZED DOCK DOORS, DOCK BUMPERS, SEALS

AND Z-GUARDS

9 CONCRETE VAULT WALL

10 EXTENT OF DEPRESSED SLAB FOR WALK-IN COOLER

11 GENERATOR TEST PAD

12 CHILLER SLAB

17 MOTORIZED DOCK LEVELER

18 LOADING DOCK SAFETY GATE

30 SEE IF101 FOR GFGI FURNITURE

31 GUARD BUMPERS

32 PALLETS- GFGI (SHOWN FOR REFERENCE ONLY)

33 FIXED TRI-WALL PALLET RACK, 9'W 4'D 15'H

34 FIXED TRI-WALL PALLET RACK, 5'W 4'D 15'H

35 EMERGENCY EYE WASH/SHOWER

36 ELECTRIC WATER COOLER (DUAL HT) SEE - 2/A-400

37 PARTITION TYPE 1A6 ON TOP OF CMU WALL

38 PARTITION TYPE A6 ON TOP OF CMU WALL

39 REFRIGERATOR, GFGI

40 CHARGING RACKS - GFGI (SHOWN FOR REFERENCE

ONLY)

42 ELECTRICAL FORKLIFT CHARGING AND STAGING

AREA. PAINT 4" DIAGONAL STRIPES, SAFETY YELLOW.

43 ELECTRICAL FORKLIFT CHARGING STATION (GFGI)

44 BMET WORK AREA - LARGE EQUIPMENT GFGI

45 FLOOR SCRUBBER CHARGING STATION (GFGI)

46 5'-0" PEDESTRIAN SAFETY AISLE, PAINT 4" DIAGONAL

STRIPES, SAFETY YELLOW

47 TV, GFGI- SEE 4/A-550 FOR BLOCKING RQMTS

48 SHELVING STORAGE UNIT - SEE 6/A-553

49 FLOOR SINK

50 UTILITY SINK

N

PROJECT

NORTH

N

TRUE

NORTH

0 4' 8' 16'

B

F

CA

E D

KEYPLAN

E

21 23 2520 22 24

D

/REFER TO 1 A-101D

R

E F

E R

-1

B

CLEAR

30' - 10"

CLEAR

33' - 3" C

L E

A R

TYP

26' - 5" 26' - 5" 26' - 5" 26' - 5" 27' - 7" 8"

TYP

WAREHOUSE

1A6

C L E

A R

/8

CLEAR

30' - 4 3/4"

A L

IG

N

B

1220 Marshall Street NE Minneapolis, MN 55413-1036…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .