This document is an Electronic Engineering Data (EED) File Manifest submitted by the Connecticut Department of Transportation for the Rehabilitation of Bridge No. 02150 in the Town of Stratford (Project Number 0138-0252). The manifest was prepared by Samuel Hopkins of Clough Harbor and Associates, LLP on July 21, 2026, and includes comprehensive engineering design files utilizing North American Datum 1983 (2011) and North American Vertical Datum 1988. The submission contains multiple CAD files organized by discipline, including survey data, hydraulic analysis, right-of-way information, access road design, existing and proposed bridge structure models, and sanitary sewer infrastructure. The deliverables encompass terrain models with 3D contours, FEMA flood line mapping, riprap basin design, alignment geometry, and bridge structural components including centerlines for bearings and girders.
The manifest is accompanied by a comprehensive Electronic Engineering Data Quality Control Checklist that verifies compliance with Connecticut Department of Transportation standards for the CTDOT Digital Design Environment (DDE). All CAD files are confirmed to be compatible with current departmental specifications, with elements positioned in real-world modified state plane coordinates and geospatially correct placement. The submission confirms that design models are free of extraneous construction lines, cross-sections, and annotation, with clean reference attachments containing only necessary files. All 3D files have been verified for proper elevation without irregular dips or spikes, and terrain models have been validated to ensure contours align with proposed drainage structures and that surfaces meet construction equipment tolerance requirements for automated machine control and guidance purposes.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EED File Manifest
| Electronic Engineering Data File Manifest | |
| Project Number: | 0138-0252 |
| Date: | 21-Jul-26 |
| Submitted by: | Samuel Hopkins |
| Email: | shopkins@chasolutions.com |
| Phone #: | (860) 206-1266 |
| Unit/Company Name: | Clough Harbor and Associates, LLP |
| Survey Ground File Datum: | N.A.D. 1983 (2011) / N.A.V.D. 1988 |
| The files listed on the attached manifest have been reviewed in accordance with EED Guidelines and are ready for EED submission. | |
| File Name | Desciption / Notes |
| SV_D4_0138_0252_STRATFORD_BR_02150_GRN | Existing Survey, including Terrain Model & Annot. |
| PrelimPermitLinework | FEMA Flood Lines (Calculated & Mapped) |
| 0138-0252_Stratford02150_RevHydraulicLinework | Riprap Basin Grade Lines |
| SV_CB_0138_0252_Stratford_Master | Survey Master File - All Survey Base Files Rerefenced In |
| HW_CB_0138_0252_ROW_Lines | Right of Way Lines |
| HW_CB_0138_0252_Alignment | Access Road Centerline Alignment |
| HW_CB_0138_0252_Contours | Access Road Contours |
| HW_CB_0138_0252_Layout | Access Road Layout |
| SB_CB_0138_0252_Bridge02150_Existing | Bridge No. 02150 Existing Structure Model |
| SB_CB_0138_0252_Bridge02150_Proposed | Bridge No. 02150 Proposed Structure Model |
| SB_CB_0138_0252_Master | Bridge Master File - All Structure Base Files Rerefenced In |
| SB_CB_0138_0252_San_Master | Sanitary Sewer Master File - All Sanitary Sewer Base Files Rerefenced In |
Connecticut Department of Transportation Electronic Engineering Data File Manifest Page &P of &N mailto:shopkins@chasolutions.com EED QC Checklist
| Electronic Engineering Data Quality Control Checklist | |
| DGN Files | |
| All CAD Files are compatible with CTDOT’s current CTDOT Digital Design Environment (DDE). | |
| Elements are placed in real world modified state plane coordinates and be geospatially correct. | |
| Delivered Model Types are Design Models only (no Sheet Models or Drawing Models are required). | |
| All graphical elements are at the correct geospatial location. | |
| All graphical elements are placed on the correct CTDOT Level. | |
| Files are free of all cross sections, profiles, construction lines for design purposes. | |
| Files are free of annotation that should reside in the cut sheets. | |
| Files have clean reference attachments, only needed reference files & no redundant references. | |
| 3D DGN Files | |
| All 3D files have lines and elements at the proper elevation (no spikes). | |
| Proposed Coordinate Geometry DGN Files | |
| Only final coordinate geometry alignments are included (preliminary and alternate information has been removed). | |
| Coordinate geometry alignments names and descriptions are intuitive. | |
| Proposed Structure/Bridge DGN Files | |
| Structure centerlines of bearings are included. | |
| Structure centerlines of girders are included. | |
| Elements are placed using CTDOT’s customized Bentley Software tools. | |
| Components modeled using OpenBridge are Feature Model Elements. | |
| All elements are placed at 1:1 scale. | |
| Proposed Traffic DGN Files | |
| All element in Signal Equipment and Signs models have the proper Item Types attached as directed in the CTDOT CAD Manual. | |
| CTDOT CONNECT DDE GUIDE VOLUME 6 - TRAFFIC ENGINEERING BASE MODELING | |
| Terrain Models and 3D Meshes | |
| Visualized both the contours and triangles in a 3D file. Looked at it from the top and front, side, and isometric view. No irregular dips, spikes or voids in the surface are apparent. | |
| Triangles were viewed on top of the proposed design file. The triangles do not cross obvious breaklines such as centerlines, edges of pavement, edges of shoulders, etc. | |
| Contours were viewed to ensure the low points line up with the proposed drainage structures and structure flowlines match the proposed surface. | |
| In critical areas (i.e. intersections), contours were viewed at construction equipment tolerance intervals (typically 1” or less) to insure smooth surfaces for automated machine control/guidance purposes. | |
| No vertical faces are present (all vertical surfaces are to be offset a minimum of 1/12 in – 1/8 in to be accepted into the AMG software). |
Directions:
Start by selecting INCLUDED or N/A (not included) for each section below. If INCLUDED is selected check to make sure each item in that section is correctly incorporated. If N/A (not included) is selected, items under that section will not need to be checked.
Please note the first section is always included, so this drop box can not be changed.
https://portal.ct.gov/DOT/Engineering-Applications/CTDOT-CONNECT-DDE-eBook-Volume-006---Traffic-Engineering-Base-Modeling/Section-1---Traffic-Engineering-Base-Modeling-Overviewhttps://portal.ct.gov/DOT/Engineering-Applications/CTDOT---CONNECT-DDE Pick list
| INCLUDED |
| N/A (not included) |
image1.png image2.png