0138-0252_07_Sanitary Sewer.pdf
PDF 5 MB Posted
- Solicitation number
- 0138-0252
- Issued by
- Fairfield County, Connecticut
About this file
This is a set of construction contract plans prepared by Clough, Harbour & Associates, LLP for the Connecticut Department of Transportation regarding sanitary sewer work associated with the Rehabilitation of Bridge No. 02150 in Stratford. The project involves the replacement and rehabilitation of sanitary sewer infrastructure that crosses Freeman Brook on Route 15. The scope of work includes removal of approximately 75.88 linear feet of existing 15-inch asbestos cement (A.C.) sanitary sewer pipe and installation of new 15-inch SDR-35 polyvinyl chloride (PVC) pipe, construction of three proposed 48-inch diameter precast reinforced concrete sanitary sewer manholes with cast-in-place concrete structures at the culvert outlet, removal of existing sanitary sewer encasement concrete, and implementation of a temporary sanitary sewer bypass system capable of handling peak flows of 1,125,000 gallons per day with a maximum discharge of 200,000 gallons per day. The plans include detailed drawings covering sanitary sewer plans and profiles, temporary bypass configurations, miscellaneous details for manhole construction and pipe encasement, removal limits at the culvert outlet, and manhole frame and cover specifications.
The contract documents specify that the proposed sanitary sewer main shall consist of SDR-35 polyvinyl chloride pipe with all materials, tools, and labor for trench excavation, bedding material, granular fill, geotextile, detectable warning tape, testing, and jointing to be included under item #1400107. Precast reinforced concrete manholes and all associated materials and labor are to be paid under item #1403001A. Rock removal encountered during trench excavation is to be paid under item #1400004. The removal of existing concrete encasement for the sanitary sewer downstream of the box culvert outlet shall be paid under item #0974001 for removal of existing masonry. Drilling holes into bedrock and bonding rock anchors shall be paid under item #0610001A. The contractor bears responsibility for installation, maintenance, and removal of the temporary sanitary sewer bypass system, coordination with the town and affected private property owners, and compliance with all environmental permits and construction activity requirements. Asbestos abatement for contaminated demolition materials is a separate contract item, with special provisions requiring appropriate precautions for handling and disposal.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MISCELLANEOUS SANITARY SEWER DETAILS IVSAN-07
MISCELLANEOUS SANITARY SEWER DETAILS IIISAN-06
MISCELLANEOUS SANITARY SEWER DETAILS IISAN-05
MISCELLANEOUS SANITARY SEWER DETAILS ISAN-04
TEMPORAY SANITARY SEWER BYPASS PLANSAN-03
SANITARY SEWER PLAN AND PROFILESAN-02
SANITARY SEWER INDEX OF DRAWINGSSAN-01
DRAWING TITLEDRAWING NUMBERDRAWING TITLEDRAWING NUMBER
INDEX OF DRAWINGS
07 - SANITARY SEWER
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
SAN-01
TOWN(S):
STRATFORD
CARRYING ROUTE 15 OVER FREEMAN BROOK
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\SS_CP_0138_0252_SAN_01_Subset_Cover_Sheet.dgn FILE NAME: 6610 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N
0138-0252
DESIGNER/DRAFTER: CHECKED BY:
INDEX OF DRAWINGS
SANITARY SEWER
TRANSPORTATION
DEPARTMENT OF
CONNECTICUT
DESIGNED BY:
Associates, LLP
Clough, Harbour &
Rocky Hill, CT 06067
400 Capital Boulevard, Suite 301
CEPSJH 07.01
Clough, Harbour & Associates, LLP 400 Capital Boulevard, Suite 301 Rocky Hill, CT 06067
O
W
B
F N
D
C H
D
W O
O D
B E
A M
R A
IL
C O
N C
C
U R
B
W O
O D
B E
A M
R A
IL
C O
N C
C U
R B
W O
O D B
E A
M R
A
IL
C H
A
IN
L
IN
K F
E N
C E
STRUCTURE #02150 (10' X 8' BOX CULVERT)
W O
O D
B E
A M
R A
IL
+0
S T O
N E W
A L L
S T O
N E W
A L L
15" RCP 15" RCP
15" RCP 15" RCP
SA
N
(ENCASED IN CONC.)
15" SAN. SEWER
R O
W M
A P
-1
E S
H E E T
A R
O W M
A P
-1
E S
H E E T
A
H Y
D R
O S E
C T
IO
N
D O
W N
S T R
E A
M
15" SAN.
SA
N
15" SAN.
15" SAN. SEWER
(ENCASED IN CONC.)
S20°38'08"E
29.20'
End Sta. 0+75.88
N 649409.30
E 901275.19
P I 0
.6
N
.6
E
.9
S20°16'04"E
5.00'
B e g in S ta
.0
N
.0
E
.8
S25°08'19"W
42.00'
P I 0
.0
N
.3
E
.6
0+00
0+00
1+00
1+00
80 80
90 90
100 100
LF
O
F " S
D R P .V .C
SD
R35 P.V
.C
±24 LF O
F 15"
.6
IN
V O
U T
IN
V
I N
.7
R
IM
.8
.6
S T
A
S M
H
.2
IN
V O
U
IN
V
I N
.3
R
IM
.0
.8
S T
A
S M
H
EX. 15" A.C
. PIPE
IN
V
O U
T
.3
.4
IN
V I
R
IM
.9
.0
S T
A
C U
L V
E R
T O
U T
L E
T
M H
/A C
C E
S S
A
PROPOSED GRADE
EXISTING GRADE
IN BOX CULVERT
EX. 15" C.I. PIPE
EPD
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/21/2026
SIGNATURE BLOCK: DRAWING TITLE:
SAN-02
15 OVER FREEMAN BROOK
REHABILITATION OF BRIDGE NO. 02150; CARRYING ROUTE
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\SS_CP_0138_0252_SAN_02_Sewer_Plan_Profile.dgn FILE NAME: 8646 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
AND PROFILE
SANITARY SEWER PLAN
TRANSPORTATION
(2
3COORDIN
ATE
GRID
D
CONNECTIC
UT
OHW
INV IN = 85.31, INV OUT = 85.21
STA. 0+70.9, TF = 93.00
PROPOSED SANITARY SEWER MANHOLE
INV IN = 86.75, INV OUT = 86.65
STA. 0+46.7, TF = 96.85
PROPOSED SANITARY SEWER MANHOLE
INV IN = 92.40, INV OUT = 92.30
STA. 0+05.0, TF = 94.90
PROPOSED SANITARY SEWER MANHOLE
ENCASEMENT TO BE REMOVED
CONCRETE MANHOLE AND
EXISTING SANITARY SEWER
TO BE REMOVED
EXISTING SANITARY MANHOLE
PIPE AT 6% SLOPE
MATCH EXIST. 15" A.C.
42' LENGTH x 15" SDR35 P.V.C. PIPE
20' LENGTH x 15" SDR35 P.V.C. PIPE
EXISTING 15" SAN. SEWER TO BE REMOVED
INV. = 92.4' TO BE REMOVED
EXISTING 15" SAN SEWER
A.C. PIPE AT 3% SLOPE
MATCH EXISTING 15"
HIGH VISIBILITY FENCE
HORIZONTAL SCALE IN FEET
20 40
VERTICAL SCALE IN FEET
EDGE OF WATER
ORDINARY HIGH WATER
(APPROXIMATE LOCATION)
SEDIMENTATION CONTROL SYSTEM
STATE/FEDERAL WETLANDS
EXISTING 100-YEAR FLOOD (CALCULATED)100YR
LEGEND
HIGH VISIBILITY FENCE
NOTES:
"REMOVAL OF EXISTING MASONRY"
ENCASEMENT/WALL WILL BE PAID FOR UNDER
"ASBESTOS ABATEMENT". REMOVAL OF THE EXISTING
INCLUDED UNDER PAYMENT FOR THE NEW PIPE AND
REMOVAL OF EXISTING SANITARY SEWER PIPE WILL BE 2.
#1403001A - "MANHOLE (SANITARY SEWER)".
MANHOLE STRUCTURES SHALL BE INCLUDED UNDER ITEM
REMOVAL AND DISPOSAL OF EXISTING SANITARY SEWER 1.
07.02
Clough, Harbour & Associates, LLP
(OW)
B-3 B-2
FND
CHD
WOOD BEAM RAIL
CONC. CURB
CONC. CURB
WOOD BEAM RAIL
CONC. CURB
CONC. CURB
WOOD BEAM RAIL
CHAIN LINK FENCE
S T R
U C
T U
R E
' X ' B
O X C
U L
V E
R T
WOOD BEAM RAIL
101+00 102+00 103+00
201+00 202+00 203+00
220+00 221+00
14+00
STONE WALL
STONE WALL
" R
C P
" R
C P
" R
C P
" R
C P
S A
N
E
N C
A S E
D
IN
C
O N
C
" S
A N . S
E W
E R
ROW MAP 138-180E SHEET 1A ROW MAP 138-180E SHEET 2A
" R
C P U
N D
E R
D R
A
IN
" S
A N
OHW
(2011)
C O
O R
D
IN
A T E G
R
ID
AD
C O
N N
E C
T
IC
U
20' 40'
1" = 20'
HORIZONTAL SCALE
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/21/2026
SIGNATURE BLOCK: DRAWING TITLE:
SAN-03
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\SS_CP_0138_0252_SAN_03_Sewer_Bypass.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
SEWER BYPASS PLAN
TEMPORARY SANITARY
TRANSPORTATION
100 YR
FR
EE
M A
N
BRO
O
K
F R
E E
M
B
O O
K
ROUTE 15
ROUTE 15
NORTHBOUND
SOUTHBOUND
(10' X 8'' BOX CUVLERT) TO REMAIN
EXISTING STRUCTURE BRIDGE NO. 02150
SEDIMENTATION CONTROL SYSTEM (TYP.)
PROPOSED SLOPE LIMITS (TYP.)
(SEE CONSTRUCTION NOTES)
TEMPORARY SANITARY SEWER BYPASS
SANITARY SEWER
INSTALL 15" PVC PIPE FOR
ACCESS ROAD
(SEE ACCESS ROAD PLAN)
PROPOSED STORM DRAINAGE SYSTEM
STATE/FEDERAL WETLANDS (TYP.)
TAKING LINE
EASEMENT
CONSTRUCTION
LIMITS OF PROPOSED
FENCE
VISIBILITY
HIGH
FLOOD (CALCULATED)
EXISTING 100-YEAR
INSTALL 4' DIA. MANHOLE FOR SANITARY SEWER
EXISTING 15" A.C. SANITARY SEWER PIPE
REMOVE EXISTING SANITARY SEWER MANHOLE
MANHOLE AT CULVERT OUTLET
RECONSTRUCT SANITARY SEWER
FOR SANITARY SEWER
INSTALL 4' DIA. MANHOLE
SANITARY SEWER
INSTALL 15" PVC PIPE FOR
SEWER PIPE AND ENCASEMENT
REMOVE EXISTING SANITARY
NO. S-05 FOR PLAN AND NOTES)
(SEE STRUCTURE SUBSET DRAWING
SYSTEM FOR FREEMAN BROOK
TEMPORARY WATER-HANDLING
(SEE CONSTRUCTION NOTES)
EXISTING SEWER MANHOLE
SEWER BYPASS PUMP IN
TEMPORARY SANITARY
100-YEAR FLOODPLAIN (MAPPED)
(10' X 8'' BOX CUVLERT) TO REMAIN
EXISTING STRUCTURE BRIDGE NO. 02150
APPROXIMATE ROW LIN
E
F R
E E
M
O O
K
(SEE CONSTRUCTION NOTES)
TEMPORARY SANITARY SEWER BYPASS
A .C
A .C
A .C
A .C
PIPE
SANITARY SEWER
EXISTING 15" A.C.
BIT. DRIVEWAY
15' TOWN SEWER EASEMENT
SEE PLAN VIEW AT CULVERT
(SEE CONSTRUCTION NOTES)
EXISTING SEWER MANHOLE
BYPASS DISCHARGE INTO
TEMPORARY SANITARY SEWER
SEE SCHEMATIC PLAN
F L O
W
SEWER BYPASS WORK
DURING TEMPORARY SANITARY
PROVIDE ACCESS TO HOMEOWNER
LEGEND
EDGE OF WATER
ORDINARY HIGH WATER
STATE/FEDERAL WETLANDS
(APPROXIMATE LOCATION)
SEDIMENTATION CONTROL SYSTEM
SCALE: 1"=20'
PLAN
(CALCULATED)
EXISTING 100-YEAR FLOOD
SJH CEE
200,000 GPD
TEMPORARY DESIGN DISCHARGE*
LOW FLOW PUMPING
1.5 FPSMIN. CLEANSING VELOCITY
1,125,000 GPDMAX. PEAK FLOW
425,000 GPDPEAK AVERAGE DAILY FLOW
SANITARY SEWER FLOW DATA
HIGH VISIBILITY FENCE
CONSTRUCTION NOTES:
ENGINEER FOR APPROVAL.
BYPASS SYSTEM SHALL BE SUBMITTED BY THE CONTRACTOR TO THE
A MEANS AND METHOD FOR TEMPORARY SANITARY SEWER 2.
PROJECT SPECIFICATIONS.
THE REQUIREMENTS OF THE ENVIRONMENTAL PERMIT(S) AND
CONSTRUCTION ACTIVITY, AND SHALL BE IN ACCORDANCE WITH
THROUGH THE CONSTRUCTION AREA, SHALL BE ABLE TO SUPPORT
WHICH WILL SAFELY CONVEY SEWAGE FLOWS CONTINUOUSLY
AN APPROVED SYSTEM THAT THE CONTRACTOR ELECTS TO USE
TEMPORARY SANITARY SEWER BYPASS SYSTEM SHALL CONSIST OF 1.
SANITARY SEWER BYPASS NOTES:
REFERENCES:
WATER HANDLING, AND UNCONFINED IN-STREAM WORK BMP.
AND FOR ADDITIONAL NOTES REGARDING CONSTRUCTION,
HANDLING PLAN OF FREEMAN BROOK AND STORM DRAINAGE,
SEE STRUCTURE SUBSET DRAWING NO. S-05 FOR WATER 1.
KEEP FLOWS TO A MINIMUM
AT TIME OF LITTLE RAIN AND LOW GROUNDWATER TO
INSTALLATION OF THE TEMPORARY SANITARY SEWER BYPASS SYSTEM.
PRIVATE PROPERTY OWNERS AFFECTED BY THE WORK PRIOR TO
HEREIN. THE CONTRACTOR SHALL NOTIFY THE ENGINEER, TOWN AND
WITHIN THE LIMITS OF THE EXISTING TOWN SEWER EASEMENT SHOWN
THE CONTRACTOR SHALL RUN THE BYPASS SYSTEM OVER LAND
THROUGH PRIVATE PROPERTY IN ORDER TO FACILITATE THE WORK,
IF THE TEMPORARY SANITARY SEWER BYPASS SYSTEM MUST BE ROUTED 4.
INFORMATION.
SEWER BYPASS". SEE SPECIAL PROVISIONS FOR ADDITIONAL
PAID FOR UNDER THE CONTRACT ITEM "TEMPORARY SANITARY
OF THE TEMPORARY SANITARY SEWER BYPASS SYSTEM, AND SHALL BE
RESPONSIBLE FOR THE INSTALLATION, MAINTENANCE AND REMOVAL
THE EXISTING SANITARY SEWER. THE CONTRACTOR SHALL BE
RECONSTRUCTION OF THE SANITARY SEWER AND CONNECTION TO
THE CONTRACTOR SHALL COORDINATE WITH THE TOWN DURING 3.
. NIGHT WORK MAY BE REQUIRED.
PERFORMED
SEWAGE AT ALL TIMES DURING CONSTRUCTION. WORK TO BE
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTROLLING THE 2.
LIMITS NECESSARY TO PERFORM THE CONTRACT WORK.
THE CONTRACTOR IS RESPONSIBLE FOR ACTUAL LOCATION AND 1.
HAZARDOUS MATERIALS NOTE:
SPECIAL PROVISIONS.
SEE NTC - "HAZARDOUS MATERIALS INVESTIGATIONS" AND
"ASBESTOS ABATEMENT". FOR ADDITIONAL INFORMATION,
CONTAMINATED AND SHALL BE PAID FOR UNDER ITEM
OF PIPE AND STRUCTURE DEMOLITION MATERIALS THAT ARE
PRECAUTIONS WHEN HANDLING, STORING, AND DISPOSING
CULVERT. CONTRACTOR SHALL TAKE ALL NECESSARY
LOCATED AT THE SOUTH END OF THE CONRETE BOX
ASBESTOS IS PRESENT IN THE EXISTING SANITARY SEWER PIPE
NOT TO SCALE
SCHEMATIC PLAN
*LOW FLOW RATES WERE MEASURED DURING NIGHT HOURS.
100-YEAR FLOODPLAIN (MAPPED)
N/F
NADJA MORENO
DE OLIVERIA ET AL
N/F
ROBERT H. & PANTIP
HROMJAK
N/F
WILLIAM H. III & SHAWNA
HUNTTING
N/F
ZBIGNIEW J. SLEDZ ET AL
N/F
ZBIGNIEW J. SLEDZ ET AL
N/F
ROBERT H. & PANTIP
HROMJAK
N/F
WILLIAM H. III & SHAWNA
HUNTTING
07.03
Clough, Harbour & Associates, LLP
SJH CEP
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
SAN-04
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\SS_CP_0138_0252_SAN_04-07_Misc_Details.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
SANITARY SEWER DETAILS I
MISCELLANEOUS
TRANSPORTATION
12" MIN.-16" MAX.
BY THE ENGINEER
OR AS DIRECTED
2.5% MIN.
OPTION 1 - ECCENTRIC CONE
ECCENTRIC CONE
CONCRETE MANHOLE
3' PRECAST REINFORCED
8" MIN. (TYP.)
8" MIN.
8" MIN. TYP.
OPTION 2 - FLAT SLAB TOP
4" MIN.-6" MAX.
3" MIN. EMBEDMENT
10" MIN.-16" MAX.
DETAIL - STEP FOR SANITARY SEWER MANHOLE
WALL THICKNESS
PLASTIC STEP WITH METAL CORE
COPOLYMER POLYPROPYLENE
NOTES:
BACKFILL, GRANULAR FILL, AND APPURTENANT WORK
JOINTING AND JOINTING MATERIALS, STEPS, CONCRETE FILL, MORTAR, EXCAVATION AND
GRADE RINGS, FRAMES AND COVERS, BRICK MASONRY FOR INVERTS AND BENCHES,
BASES, RISERS, TRANSITION SECTIONS, TOPS AND
ALL DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE.2.
SEE DRAWING NO. SAN-06 FOR MANHOLE FRAME AND COVER DETAILS.1.
SEWER)".
PAID FOR UNDER ITEM #1400004 - "ROCK IN TRENCH EXCAVATION 0'-10' DEEP (SANITARY
IF ROCK IS ENCOUNTERED DURING TRENCH EXCAVATION, ROCK REMOVAL SHALL BE 7.
CHLORIDE PIPE (SANITARY SEWER)". SEE SPECIAL PROVISION.
TELEVISION INSPECTION, WILL BE PAID FOR UNDER ITEM #1400107 - "15'' POLYVINYL
DETECTABLE WARNING TAPE, TESTING, JOINTING AND JOINTING MATERIAL, AND
EXCAVATION AND BACKFILL, BEDDING MATERIAL, GRANULAR FILL, GEOTEXTILE,
SEWER PIPE. ALL MATERIAS, TOOLS AND LABOR FOR THE SEWER PIPE, INCLUDING TRENCH
THE PROPOSED SANITARY SEWER MAIN SHALL BE SDR-35 POLYVINYL CHLORIDE (PVC) 6.
"15'' POLYVINYL CHLORIDE PIPE (SANITARY SEWER)". SEE SPECIAL PROVISION.
REMOVAL OF EXISTING SANITARY SEWER PIPE SHALL BE PAID FOR UNDER ITEM #1400107 - 5.
#1403001A - "MANHOLE (SANITARY SEWER)". SEE SPECIAL PROVISION.
, SHALL BE PAID FOR UNDER ITEM
FOR SANITARY SEWER, INCLUDING
ALL MATERIALS, TOOLS AND LABOR FOR PRECAST REINFORCED CONCRETE MANHOLES 4.
#1403001A - "MANHOLE (SANITARY SEWER)". SEE SPECIAL PROVISION.
REMOVAL OF EXISTING SANITARY SEWER MANHOLES SHALL BE PAID FOR UNDER ITEM 3.
SECTION - MANHOLE BASE AND RISERS
SECTION - MANHOLE TOP
PLAN - SANITARY SEWER MANHOLE INVERT
MANHOLE FOR SANITARY SEWER
DETAILS - 48" DIAMETER REINFORCED PRECAST CONCRETE
1/2"/FT
ELEVATION SECTION
FINISHED GRADE
APPROXIMATE
(SEE HIGHWAY SUBSET)
AND TURF ESTABLISHMENT
ACCESS ROAD OR TOPSOIL
BEDDING MATERIAL
12"
SEWER PIPE
PROPOSED SANITARY
(SEE NOTE 1)
FRAME AND COVER
OR GRADE RINGS
COURSES OF BRICK
WITH MAX. OF FOUR
ADJUST TO GRADE
REINFORCEMENT
FLAT TOP
REINFORCEMENT
OR GRADE RINGS
COURSES OF BRICK
WITH MAX. OF FOUR
ADJUST TO GRADE
(SEE NOTE 1)
FRAME AND COVER
STEP (SEE DETAIL)
(FILL WITH MORTAR)
LIFTING HOLES (TYP.)
REQUIRED (TYP.)
TONGUE AND GROOVE RISERS AS
PRECAST REINFORCED CONCRETE
BUTYL RUBBER JOINT SEAL (TYP.)
REINFORCEMENT (TYP.)
4'-10" O.D.
48" I.D.
4'-10" O.D.
5"5" 24" DIA.
OPENING
24" DIA.
OPENING
18"
6" MIN.
48" I.D.
4'-10" O.D.
5" (MIN.)5" (MIN.)
12" LAYER OF GRANULAR FILL*
MIN.
4"
SCALE AS NOTED
12"
SECTION - TRENCH EXCAVATION FOR SANITARY SEWER
NOT TO SCALE
A LEVEL SURFACE.
CONCRETE MAY BE USED TO PROVIDE
IS UNEVEN, UNREINFORCED
ON BEDROCK. IF BEDROCK SURFACE
MANHOLE MAY BE PLACED DIRECTLY 2.
GEOTEXTILE (SEPARATION - CLASS 1).
MAY WRAP GRANULAR FILL IN
IF SOIL IS SATURATED CONTRACTOR 1.
:NOTES*
12" (TYP.)
WRAPPED AROUND BEDDING MATERIAL
GEOTEXTILE (SEPARATION - CLASS 1)
12" 12"
M
IN
M
IN
FOR SANITARY SEWER
CONCRETE ENCASEMENT
UNREINFORCED
PIPE
SANITARY SEWER
PROPOSED
DRAINAGE PIPE
PROPOSED STORM
AT STORM DRAINAGE CROSSING
DETAIL - CONCRETE ENCASEMENT FOR SANITARY SEWER
NOT TO SCALE
12"±
SANITARY SEWER PIPE CONNECTION
NOT TO SCALE
6" MIN.
STAINLESS STEEL STRAP
FLEXIBLE SLEEVE
MANHOLE BASE
NOT TO SCALE
NOT TO SCALE
A
M
IN
B
A S
E V
A R
IE
S
R
IS
E R
V A
R
IE
S R
IS
E
R
A
SECTION - SANITARY SEWER MANHOLE INVERT
NOT TO SCALE
0.8D
BRICK BENCH
B
BRICK INVERT
12"±
6" MIN. (TYP.)
PIPE
SANITARY SEWER
PROPOSED
COMMON BACKFILL
MANHOLE BASE
DRAINAGE PIPE
PROPOSED STORM
FOR SANITARY SEWER
CONCRETE ENCASEMENT
UNREINFORCED
DETECTABLE WARNING TAPE
07.04
Clough, Harbour & Associates, LLP
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
SAN-05
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\SS_CP_0138_0252_SAN_04-07_Misc_Details.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
SANITARY SEWER DETAILS II
MISCELLANEOUS
TRANSPORTATION
ELEVATION - SANITARY SEWER REMOVAL LIMITS AT CULVERT OUTLET
SCALE:
2" = 1'-0"
FOR SANITARY SEWER
CONCRETE ENCASEMENT
REMOVE EXISTING
FACE OF EXISTING BOX CULVERT
A
A
TOP OF EXISTING ENCASEMENT
BOX CULVERT TO REMAIN
SANITARY SEWER MAIN INSIDE
EXISTING ENCASED 14" C.I. PIPE
LIMITS OF REMOVAL
FOR SANITARY SEWER (TYP.)
CONCRETE ENCASEMENT
REMOVE EXISTING
CULVERT OUTLET (TYP.)
SEWER PIPE DOWNSTREAM OF BOX
REMOVE EXISTING 15" A.C.SANITARY
FOR SANITARY SEWER
FRAME AND COVERS
REMOVE EXISTING
FACE OF EXISTING BOX CULVERT
BOX CULVERT TO REMAIN
SANITARY SEWER MAIN INSIDE
EXISTING ENCASED 14" C.I. PIPE
EXISTING WINGWALL
9'-3"±
FRAME AND COVERS
REMOVE EXISTING SANITARY SEWER
ELEVATION - RECONSTRUCTION OF SANITARY SEWER AT CULVERT OUTLET
SCALE:
2" = 1'-0"
CUTOFF WALL
EXISTING BOX CULVERT
TOP OF WALL EL. = 94.9 (LEVEL)
PROPOSED RETAINING WALL
FACE OF EXISTING BOX CULVERT
B
BE FLUSH WITH FRONT FACE OF PROPOSED CONCRETE RETAINING WALL
FRONT FACE OF CAST-IN-PLACE CONCRETE MANHOLE STRUCTURE SHALL
B
LIMITS OF RECONSTRUCTION
R E
TA
IN
IN
G W
A L L
P R
O P
O S E D
EXISTING BOX CULVERT
14" C.I. PIPE SANITARY SEWER MAIN
EXISTING CONCRETE ENCASED
EXISTING WINGWALL STEM
INSTALL 15" PVC PIPE FOR SANITARY SEWER
7'-0"
10'-0"
(S E E S
TR
U C
TU
R E S
U B S E T)
AND CONNECT TO EXISTING WITH SLEEVE
INSTALL 15" PVC PIPE FOR SANITARY SEWER
2'-9"±
CULVERT OUTLET (TYP.)
DOWNSTREAM OF BOX
SANITARY SEWER PIPE
REMOVE EXISTING 15" A.C.
TOP OF EXISTING ENCASEMENT
BOX CULVERT TO REMAIN
SANITARY SEWER MAIN INSIDE
EXISTING ENCASED 14" C.I. PIPE
BEDROCK
APPROXIMATE
FINISHED GRADE
APPROXIMATE
BRICK BENCH AND BRICK INVERT
(SEE STRUCTURE SUBSET FOR PROPOSED RETAINING WALL)
CONCRETE INVERT REPAIR
MANHOLE STRUCTURE AND INVERT
CONSTRUCT CAST-IN-PLACE CONCRETE
INSTALL SANITARY SEWER MAHOLE FRAME AND COVER
MANHOLE FRAME AND COVER
INSTALL SANITARY SEWER
FLUSH FLUSH
M
IN
E M
B E
D
(T
Y P
M
IN
(T Y
P
HAZARDOUS MATERIALS NOTE:
ASBESTOS IS PRESENT IN THE EXISTING SANITARY SEWER PIPE
LOCATED AT THE SOUTH END OF THE CONRETE BOX
CULVERT. CONTRACTOR SHALL TAKE ALL NECESSARY
PRECAUTIONS WHEN HANDLING, STORING, AND DISPOSING
OF PIPE AND STRUCTURE DEMOLITION MATERIALS THAT ARE
CONTAMINATED AND SHALL BE PAID FOR UNDER ITEM
"ASBESTOS ABATEMENT". FOR ADDITIONAL INFORMATION,
SEE NTC - "HAZARDOUS MATERIALS INVESTIGATIONS" AND
SPECIAL PROVISIONS.
NOTES:
1. SEE DRAWING NOS. SAN-04 AND SAN-06 FOR ADDITIONAL
INFORMATION.
2. SEE DRAWING NO. SAN-07 FOR FRAME AND COVER DETAILS.
2. REMOVAL OF EXISTING CONCRETE FOR THE SANITARY SEWER
ENCASEMENT DOWNSTREAM OF THE BOX CULVERT OUTLET SHALL
BE PAID FOR UNDER ITEM #0974001 - "REMOVAL OF EXISTING
MASONRY".
3. DRILLING HOLES INTO BEDROCK AND BONDING ROCK ANCHORS
SHALL BE PAID FOR UNDER ITEM #0610001A - "DRILLING HOLES
AND BONDING ANCHORS".
4. APPLY PENETRATING SEALER PROTECTIVE COMPOUND TO ALL
EXPOSED CONCRETE SURFACES AFTER CONCRETE WALL AND
MANHOLE STRUCTURE ARE CONSTRUCTED AND BACKFILLED.
(SEE STRUCTURE SUBSET)
" EXPANSION JOINT2
PLAN - SANITARY SEWER REMOVAL LIMITS AT CULVERT OUTLET
SCALE:
2" = 1'-0"
PLAN - RECONSTRUCTION OF SANITARY SEWER AT CULVERT OUTLET
SCALE:
2" = 1'-0"
CONSTRUCTION JOINT
EL. = 94.9 (LEVEL)
CONCRETE INVERT REPAIR
CULVERT BOTTOM SLAB
TOP OF EXISTING BOX
RETAINING WALL CORNER
WALL BATTER
TOE OF RET.
TOP OF RET. WALL
" EXPANSION JOINT (SEE STRUCTURE SUBSET)2
MORTAR AROUND FRAME PERIMETER
C
SAN-06
D
SAN-06
(TYP.)
#8 @ 18" ROCK ANCHOR
DRILL HOLES AND BOND
CUTOFF WALL TO REMAIN
EXISTING BOX CULVERT
BEDROCK
APPROXIMATE
EXISTING WINGWALL FOOTING
APPROXIMATE LIMITS OF
FOOTING
EXISTING WINGWALL
APPROXIMATE LIMITS OF
SCALE AS NOTED
07.05
Clough, Harbour & Associates, LLP
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
SAN-06
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\SS_CP_0138_0252_SAN_04-07_Misc_Details.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
SEWER DETAILS III
MISCELLANEOUS SANITARY
TRANSPORTATION
4 - #8 @ 18" MAX. SPA.
3'-10"
SECTION - SANITARY SEWER MANHOLE REINFORCEMENT AT CULVERT OUTLET
SCALE:
2" = 1'-0"
1'-8"
LAP
(TYP.)
SECTION - SANITARY SEWER MANHOLE REINFORCEMENT AT CULVERT OUTLET
SCALE:
2" = 1'-0"
3" COVER (TYP.)
1'-8" LAP SPLICE (TYP.)
#5 @ 12" (TYP.)
EXISTING WINGWALL FOOTING
SPACING IF NECESSARY TO AVOID
ROCK ANCHOR (TYP.) ADJUST
DRILL HOLE AND BOND #8 @ 18"
#5 @ 12" (TYP.)
MANHOLE STRUCTURE AND INVERT
CONSTRUCT CAST-IN-PLACE CONCRETE
3" COVER (TYP.)
#5 @ 12" (TYP.)
#5 @ 12" (TYP.)
FORM MANHOLE OPENING
BRICK BENCH (TYP.)
BRICK INVERT
APPROXIMATE LIMITS OF EXISTING WINGWALL FOOTING
EXISTING WINGWALL STEM
LIMITS OF PROPOSED RETAINING WALL
LIMITS OF PROPOSED RETAINING WALL
MANHOLE STRUCTURE AND INVERT
CONSTRUCT CAST-IN-PLACE CONCRETE EXISTING BOX CULVERT CUTOFF WALL
EXISTING BOX CULVERT
14" C.I. PIPE SANITARY SEWER MAIN
EXISTING CONCRETE ENCASED
EXISTING BOX CULVERT
2'-3"
I.D.
D
C
SAN-05
CONCRETE INVERT REPAIR LIMITS
NOTES:
1. SEE DRAWING NO. SAN-05 FOR ADDITIONAL INFORMATION.
2. ALL WORK AND MATERIALS, INCLUDING CAST-IN-PLACE CONCRETE
AND STEEL REINFORCEMENT, FOR CONSTRUCTING THE SANITARY SEWER
MANHOLE AT THE CULVERT OUTLET SHALL BE INCLUDED FOR PAYMENT
UNDER ITEM #1403001A - "MANHOLE (SANITARY SEWER)."
3. REINFORCEMENT FOR THIS STRUCTURE SHALL BE HOT-DIP GALVANIZED.
SEE STRUCTURE SUBSET DRAWING NO. S-03 FOR CONCRETE NOTES.
(T Y
P
SAN-05
DETAIL - SANITARY SEWER MANHOLE AT CULVERT OUTLET
SCALE:
2" = 1'-0"
M
IN
(T Y
P
B
A R
S E
Q U
A L
L Y
S P
A C
E D
E
.F
EL. = 94.9 (LEVEL)
ROCK ANCHOR
BOND #8 @ 18"
DRILL HOLES AND
APPROXIMATE FINISHED GRADE (TYP.)
PROPOSED SANITARY SEWER PIPE
LIMITS OF EXCAVATION
2'-0" 2'-0"
FOR MANHOLE (SANITARY SEWER)
#5 @ 12" (E.F.)
3" COVER (TYP.)
APPLY PENETRATING SEALER TO
FRONT, TOP AND BACK OF MANHOLE
EXISTING WINGWALL STEM
EXISTING WINGWALL STEM
SCALE AS NOTED
07.06
Clough, Harbour & Associates, LLP
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
SAN-07
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\SS_CP_0138_0252_SAN_04-07_Misc_Details.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
SANITARY SEWER DETAILS IV
MISCELLANEOUS
TRANSPORTATION
M M D
D Y
DETAIL "A"
CLEAR OPENING
24"
" 4
36" MIN.
6" MIN.
28" DIA. DIAMOND TREAD PATTERN
⅛" TYP." TYP.4
R = ⅛" TYP.
SEE DETAIL "A"
USAMADE IN
M M /D
D /Y
Y
STR
A
TFO
R D
PICK HOLE (TYP.)
USAMADE IN
STR
A
TFO
R
D M
M /D
D /Y
NOTES:
ITEM #1403001A - "MANHOLE (SANITARY SEWER)".
FRAME AND COVER FOR SANITARY SEWER MANHOLE SHALL BE PAID FOR UNDER 3.
COVER (PLACED ON UNDERSIDE).
CASTING DATE SHALL BE INDICATED ON EACH; FRAME ( SEE DETAIL A) AND 2.
ALL DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE.1.
" TYP.16
" TYP.16
STRATFORD
STRATFORD
STRATFORD
S
TR
A
TF
O R
D
PLAN - MANHOLE COVER
NOT TO SCALE
ISOMETRIC VIEW - MANHOLE FRAME AND COVER
NOT TO SCALE
PICK HOLE (TYP.)
SECTION - MANHOLE FRAME AND COVER
NOT TO SCALE
PLAN - MANHOLE FRAME AND COVER
NOT TO SCALE
SECTION - MANHOLE COVER WITH DIAMOND PATTERN
NOT TO SCALE
PLAN - MANHOLE COVER WITH DIAMOND PATTERN
NOT TO SCALE
( OPTIONAL )
STRATFORD
" RAISED LETTERS 4
( OPTIONAL )
"STRATFORD"
" RAISED LETTERS 2
( OPTIONAL )
CASTING DATE: MM/DD/YY
⅜" NUMBERS
SEE DETAIL
(DIAMOND PATTERN)
NON-SKID
LETTERS "2
MM/DD/YY
IMPRINT
CASTING DATE
IMPRINT
STRATFORD
SCALE AS NOTED
07.07
Clough, Harbour & Associates, LLP
| 01_Subset_Cover_Sheet |
| 02_Sewer_Plan_Profile |
| 03_Sewer_Bypass |
| 04_Misc_Details I |
| 05_Misc_Details II |
| 06_Misc_Details III |
| 07_Misc_Details IV |
| 2026-07-23T12:37:11-0400 | |
| Bryan L Busch -- CHA Consulting Inc. |
File details come from the government source that posted it. Updated .