0138-0252_04_Structure.pdf
PDF 11 MB Posted
- Solicitation number
- 0138-0252
- Issued by
- Fairfield County, Connecticut
About this file
This is a structural contract document set issued by the Connecticut Department of Transportation for the rehabilitation of Bridge No. 02150 in Stratford, Connecticut, which carries Route 15 over Freeman Brook. The project involves comprehensive repair and restoration of an existing 10-foot by 8-foot box culvert structure, including cleaning the culvert interior, performing concrete repairs to walls, slabs, wingwalls, and footings, crack sealing and curtain wall sealing, concrete invert repair with a 4-inch thick cast-in-place concrete overlay, installation of new sanitary sewer and storm drainage systems with manholes and headwalls, construction of a concrete retaining wall, riprap basin installation, and site restoration including temporary access roads and erosion control measures. The work scope encompasses 201 feet 4 inches of existing culvert requiring rehabilitation, with design specifications based on AASHTO LRFD Bridge Design Specifications (Tenth Edition – 2024), Connecticut Department of Transportation Form 819 specifications, and supplemental specifications dated January 2026. The project utilizes HL-93 live load standards with concrete strength requirements of 4,000 PSI for culvert and wingwall repairs and 3,000 PSI for culvert bottom slab repairs.
The contract specifications detail extensive concrete repair procedures including removal of deteriorated material, reinforcing bar replacement and splicing, installation of embedded galvanic anodes for corrosion protection, welded wire reinforcement in repair areas, and application of penetrating concrete sealer upon completion. Hydraulic design parameters for Freeman Brook establish a 50-year design frequency with 295 cubic feet per second discharge, upstream design water surface elevation of 108.4 feet, and downstream elevation of 89.8 feet. The project includes temporary water handling systems with cofferdam installation, temporary earth retaining systems, and temporary sanitary sewer bypass systems to maintain operations during construction. Environmental considerations include coordination with state and federal wetlands areas, restrictions on unconfined in-stream work limited to June 1 through September 30, and endangered species protection measures including restrictions on tree trimming and removal from April 15 through October 31. Adhesive bonded anchor installation with proof load testing is required for structural repairs, with minimum characteristic bond stress requirements of 1.00 KSI in dry, cracked concrete and 2.5 KSI minimum compressive strength for existing concrete in anchor design.
View the file
Other files
Show all 48
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CULVERT REPAIR DETAILS IIIS-10
CULVERT REPAIR DETAILS IIS-09
CULVERT REPAIR DETAILS IS-08
EXISTING STRUCTURE CONDITIONSS-07
LONGITUDINAL SECTION AND ELEVATIONSS-06
SUGGESTED SEQUENCE OF CONSTRUCTION AND WATER HANDLING PLANS-05
SEALER LIMITSS-14BORING LOGSS-04
RETAINING WALL DETAILSS-13GENERAL NOTES AND SCOPE OF WORKS-03
RETAINING WALL PLAN AND ELEVATIONS-12GENERAL PLANS-02
CULVERT REPAIR DETAILS IVS-11STRUCTURE INDEX OF DRAWINGSS-01
DRAWING TITLEDRAWING NUMBERDRAWING TITLEDRAWING NUMBER
INDEX OF DRAWINGS
04 - STRUCTURE
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-01
TOWN(S):
STRATFORD
CARRYING ROUTE 15 OVER FREEMAN BROOK
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_01_Subset_Cover_Sheet.dgn FILE NAME: 6610 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N
0138-0252
DESIGNER/DRAFTER: CHECKED BY:
STRUCTURE INDEX OF DRAWINGS
TRANSPORTATION
DEPARTMENT OF
CONNECTICUT
DESIGNED BY:
Associates, LLP
Clough, Harbour &
Rocky Hill, CT 06067
400 Capital Boulevard, Suite 301
CEPSJH 04.01
K:
Clough, Harbour & Associates, LLP 400 Capital Boulevard, Suite 301 Rocky Hill, CT 06067
TANGLEWOODROAD
ROUTE 15
N.B.
TO
TRUMBULL
ROUTE 15 EXIT 53
OFF RAMP
ROUTE 15
S.B.
ROW MAP 138-180E SHEET 1A
F R
E E
M A
N B
R O
O K
FR
EE
M A
N
BR
O
O K
(OW)
B-3B-2
B-1
TA
NG
LE
W
O O
D
RO
AD
FND
CHD
FND
CHD
NON ACCESS HIGHWAY LINE
WOOD BEAM RAIL
CONC. PAVEMENT
WOOD BEAM RAIL
CONC. PAVEMENT
CONC. CURB
CONC. CURB
WOOD BEAM RAIL
CONC. CURB
CONC. CURB
WOOD BEAM RAIL
CONC. CURB
CONC. CURB
WOOD BEAM RAIL
WOOD BEAM RAIL
CP-3
CHAIN LINK FENCE
CHAIN LINK FENCE
WOOD FENCE
S T R
U C
T U
R E
' X ' B
O X C
U L
V E
R T
FND
CHD
WOOD BEAM RAIL
WOOD BEAM RAIL
BCLC
BCLC
#4616
SNET
W G
HYD
8" WATER MAIN
APPROX. LOC
W1-6
W1-7
W1-5
W1-8
W1-9
W1-11
W1-12
W1-13
W1-14
W1-15
W1-16
W1-17
W1-18
W1-19
W1-10
W1-20
W1-21
W1-22
W1-23
W1-24
W1-25
W1-26
W1-27
W1-28
W1-29
W1-30
W1-31 W1-32
W1-33
W1-35
W1-36
W1-38
W1-34
W1-37
W1-39
W1-40
W1-41 W1-42
W1-43
W1-44
W1-45
W1-46
W1-48
W1-50
W1-47
W1-49
W1-51
W1-52
W1-53
W1-54
W2-1
W2-2
W2-3
W2-4
W2-5
W2-6
W2-7
W2-8
W2-9
W2-10
W2-11
W2-12
W2-13 W2-14
W2-15
W2-16
W2-17
W2-18
W3-1
W3-2
W3-3
W3-4
W3-5
W3-6
W3-7
W3-8
W1-58
W1-59
W1-60
W1-61
W1-62
W1-68
W1-69
W1-70
W1-71
W1-80
W1-81
W1-82
W1-83
W1-85
W1-86
W1-87
W1-84
WA-23
WA-22
WA-5
WA-4
WA-6
WA-7
WA-8
WA-9
WA-10
WA-11
WA-12
WA-13 WA-14
WA-15
WA-16
WA-17
WA-18
WA-19
WA-20
WA-21
WC-2
WC-3
WC-4
WC-5
WC-6
WC-7
WC-8
WC-9
WC-10
WC-11
WB-4
WB-5
WB-6
WB-7
WB-8
20'
88'
86'
0'
5'
0'
95'
5'
100+00 97+00 98+00 99+00
101+00 102+00 103+00
197+00 198+00 199+00 200+00 201+00 202+00 203+00
220+00 221+00
11+00 12+00
13+00 14+00
HUNTTING
WILLIAM H. III & SHAWNA
N/F
STONE WALLSTONE WALL
OAK
15"
OAK
15"
DOGWOOD
4"
DOGWOOD
4" TRIPLE
" R
C P
" R
C P
" R
C P
" R
C P
18" RCPLOCATED
NOT
INLET
" R
C P
R C
P
" R
C P
S A
N
E
N C
A S E
D
IN
C
O N
C
" S
A N . S
E W
E R
ROW MAP 138-180E SHEET 1A ROW MAP 138-180E SHEET 2A
" R
C P U
N D
E R
D R
A
IN
" S
A N
S A
N
" S
A N
" S
A N . S
E W
E R
E
N C
A S E
D
IN
C
O N
C
(2011)
C O
O R
D
IN
A T E G
R
ID
AD
C O
N N
E C
T
IC
U T
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-02
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_02_General_Plan.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
GENERAL PLAN
TRANSPORTATION
PERMANENT ACCESS ROAD
(TYP.)
STATE/FEDERAL WETLANDS
EXISTING BRIDGE NO. 02150 TO REMAIN
SLOPE LIMITS (TYP.) LEDGE IN CHANNEL
AREA OF EXPOSED
REMOVE EXISTING ENDWALL
EXISTING RIGHT OF WAY
STONE UP TO EL. 90 FT
12" DEPTH OF 2" CRUSHED
STANDARD RIPRAP OVER
MATERIAL WASH-IN TO 36"
OF NATURAL STREAMBED
RIPRAP BASIN CONSISTING
2" CRUSHED STONE
OVER 12" DEPTH OF
36" STANDARD RIPRAP
(CALCULATED) (TYP.)
EXISTING 100-YEAR FLOOD
INV. IN = 93.00
STA. 14+62.3, 14.1' LT
PROPOSED HEADWALL
: 9.6 FT/S10MAX V
: 15.5 CFS10MAX Q
INV. OUT = 89.50
STA. 14+82.2, 22.4' RT
ENCASED IN CONC.
PROPOSED OUTLET
36" R.C. PIPE CLASS V
INV. OUT = 90.00
INV IN (N) = 91.75
INV IN. (W) = 90.50
TF = 96.23
STA. 14+69.6, 2.2' LT
TYPE II CATCH BASIN
PROPOSED TYPE "C-L" DOUBLE GRATE
15" R.C. PIPE CLASS V
INV. OUT = 95.25
INV IN. = 97.00
TF = 101.00
STA. 15+14.7, 3.4' LT
PROPOSED MANHOLE
30" R.C. PIPE CLASS V
FOR STORM DRAINAGE PIPE
CONCRETE ENCASEMENT
PIPE (SANITARY SEWER)
15" DIA. POLYVINYL CHLORIDE
EL. 88 FT
BOULDERS WITH TOP
2.5 - 3.5 FT ROUNDED
INSTALL A LINE OF
CHANNEL PROTECTION
STANDARD RIPRAP
APPROX. EDGE OF
STONE CHECK DAM (TYP.)
*REPAIR CULVERT
INVERT WITH 4" THICK
CAST-IN-PLACE
CONCRETE INVERT
ACCESS ROAD (SEE HIGHWAY SUBSET)
LIMITS OF FRENCH MATTRESS BELOW
SEDIMENT CONTROL SYSTEM (TYP.)
(4" MIN.)
MATERIAL
STREAMBED
SUPPLEMENTALWETLAND B
WETLAND C
WETLAND A
UNNAMED
WATERCOURSE 2
UNNAMED WATERCOURSE 3
FENCE
HIGH VISIBILITY
CONCRETE RETAINING WALL NO. 101
MANHOLE (SANITARY SEWER) (TYP.)
REMOVE EXISTING SANITARY SEWER MANHOLEINV. IN = 121.75
STA. 12+40, 8.81' RT
PROPOSED HEADWALL
15" R.C. PIPE CLASS V
INV. OUT = 121.37
STA. 12+40, 10.77' LT
PROPOSED OUTLET
(SEE SANITARY SEWER SUBSET)
RECONSTRUCT SANITARY SEWER MANHOLE
100-YEAR FLOODPLAIN (MAPPED)
4' CHAIN LINK FENCE
18" INTERMEDIATE RIPRAP SWALE
ANTI-TRACKING PAD
12" MODIFIED RIPRAP
12" MODIFIED RIPRAP
18" INTERMEDIATE RIPRAP APRON
18" INTERMEDIATE RIPRAP SLOPE PROTECTION
12" MODIFIED RIPRAP
1" = 20'
HORIZONTAL SCALE
20' 40'
LEGEND
OHW
EDGE OF WATER
ORDINARY HIGH WATER
STATE/FEDERAL WETLANDS
100 YEAR FLOODPLAIN LIMITS (MAPPED)
EXISTING 100-YEAR FLOOD (CALCULATED)100YR
36" STANDARD RIPRAP OVER 12" DEPTH OF 2" CRUSHED STONE
NATURAL STREAMBED MATERIAL WASHED-IN TO
36" STANDARD RIPRAP OVER 12" DEPTH OF 2" CRUSHED STONE
18" INTERMEDIATE RIPRAP SLOPE PROTECTION
EROSION CONTROL MATTING TYPE D
SJH CEP
SEDIMENTATION CONTROL SYSTEM (APPROXIMATE LOCATION)
HIGH VISIBILITY FENCE FOR FREEMAN BROOK.
SEE DRAWING S-03 FOR HYDRAULIC DATA TABLE 2.
EAST OF THIS FENCE IS STRICTLY FORBIDDEN.
AREA OF ENVIRONMENTAL SENSITIVELY. ACCESS
THE AREA EAST OF THE HIGH VISIBILITY FENCE IS AN 1.
:NOTES
NUMBER
RETAINING WALL
DESCRIPTION LOCATION
WALL
RETAINING
CONCRETE
14+75
STATION
BEGIN
12" MODIFIED RIPRAP
N/F
WILLIAM H. III & SHAWNA
HUNTTING
N/F
ROBERT H. & PANTIP
HROMJAK
N/F
NADJA MORENO
DE OLIVERIA ET AL
N/F
ZBIGNIEW J. SLEDZ ET AL
04.02
K:
Clough, Harbour & Associates, LLP
NOTICE TO BRIDGE INSPECTORS
STRUCTURE SHEET REFERENCE
BY THE MANAGER OF BRIDGE SAFETY AND EVALUATION.
MANUALS FOR BRIDGE INSPECTION, UNLESS OTHERWISE DIRECTED
STRUCTURE SHALL BE IN ACCORDANCE WITH THE GOVERNING
THE STRUCTURE). THE FREQUENCY OF INSPECTION OF THIS
IMPORTANCE OF INSPECTION OF ANY OTHER COMPONENT OF
ATTENTION SHALL NOT BE CONSTRUED TO REDUCE THE
DETAILS. (THE LISTING FOR COMPONENTS FOR SPECIFIC
TO INSPECTION THE FOLLOWING SPECIAL COMPONENTS AND
MANUALS FOR BRIDGE INSPECTION. ATTENTION MUST BE GIVEN
APPROPRIATE COMPONENTS INDICATED IN THE GOVERNING
BRIDGE TO BE INSPECTED FOR, BUT NOT LIMITED TO, ALL
THE DEPARTMENT'S BRIDGE SAFETY PROCEDURES REQUIRE THIS
INSPECTION PROCEDURES
FOLLOW NORMAL
COMPONENT OR DETAIL
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-03
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_03_General Notes.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
SCOPE OF WORK
GENERAL NOTES AND
TRANSPORTATION
: N/AMASH TEST LEVEL
CONTRACTOR SHALL COORDINATE ALL WORK RELATED TO UTILITY RELOCATION WITH THE TOWN.
PROTECTED DURING CONSTRUCTION: TOWN OF STRATFORD (SANITARY SEWER). THE
: THE FOLLOWING UTILITIES ARE LOCATED WITHIN THE PROJECT LIMITS AND SHALL BE UTILITIES
SUBMITTED FOR REFERENCE BY THE REVIEWER.
MEASUREMENTS ARE SUBMITTED FOR REVIEW, THE FIELD MEASUREMENTS SHALL ALSO BE
FULL RESPONSIBILITY FOR THEIR ACCURACY. WHEN SHOP DRAWINGS BASED ON FIELD
MEASUREMENTS NECESSARY TO ASSURE PROPER FIT OF THE FINISHED WORK AND SHALL ASSUME
DRAWINGS AND ARE NOT GUARANTEED. THE CONTRACTOR SHALL TAKE ALL FIELD
FOR GENERAL REFERENCE ONLY. THEY HAVE BEEN TAKEN FROM THE ORIGINAL DESIGN
: DIMENSIONS OF THE EXISTING STRUCTURE SHOWN ON THESE PLANS ARE EXISTING DIMENSIONS
THE OMITTED DIGITS SHALL BE ASSUMED TO BE ZEROS.
: WHEN DECIMAL DIMENSIONS ARE GIVEN TO LESS THAN THREE DECIMAL PLACES, DIMENSIONS
SPECIFICATIONS.
DETAILS SHEET REFER TO THE GROUP LOADS AS GIVEN IN THE AASHTO LRFD BRIDGE DESIGN
: THE VARIOUS GROUP LOADINGS NOTED ON THE RETAINING WALL FOUNDATION PRESSURES
: N/ABITUMINOUS CONCRETE OVERLAY
: NONEFUTURE PAVING ALLOWANCE
: HL-93LIVE LOAD
: (ASTM A615 GRADE 60)..........fy = 60,000 PSIREINFORCEMENT
PORTLAND CEMENT CONCRETE.
SHALL CONFORM TO THE REQUIREMENTS OF 6.01 - CONCRETE FOR STRUCTURES, AND M.03 -
ABOVE. THE COMPRESSIVE STRENGTH OF THE CONCRETE IN THE CONSTRUCTED COMPONENTS
THE CONCRETE STRENGTH, f’c, USED IN DESIGN OF THE CONCRETE COMPONENTS IS NOTED
CLASS PCC04483 .................................................f'c = 4,000 PSI CLASS PCC03340 .................................................f'c = 3,000 PSI
CONCRETE:
: MATERIAL STRENGTHS
ROADWAY STRUCTURE DESIGN MANUAL (RELEASE 1.1).
AS SUPPLEMENTED BY THE CONNECTICUT DEPARTMENT OF TRANSPORTATION BRIDGE AND
: AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS (TENTH EDITION - 2024), DESIGN SPECIFICATIONS
SUPPLEMENTAL SPECIFICATIONS DATED JANUARY 2026, AND SPECIAL PROVISIONS.
: CONNECTICUT DEPARTMENT OF TRANSPORTATION FORM 819 (2024), SPECIFICATIONS
GENERAL NOTES
BE PERMITTED WITHOUT THE PRIOR APPROVAL OF THE ENGINEER.
: CONSTRUCTION JOINTS, OTHER THAN THOSE SHOWN ON THE PLANS, WILL NOT CONSTRUCTION JOINTS
INCLUDED IN THE ITEM "1/2" CLOSED CELL ELASTOMER".
: FURNISHING AND INSTALLED CLOSED CELL ELASTOMER SHALL BE CLOSED CELL ELASTOMER
PLACING THIS REINFORCEMENT SHALL BE INCLUDED IN THE ITEM "DEFORMED STEEL BARS".
SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615, GRADE 60. THE COST OF FURNISHING AND CONNECTED SHALL BE UNCOATED BAR UNLESS NOTED OTHERWISE. UNCOATED BAR REINFORCEMENT
REINFORCEMENT FOR REPAIR CONCRETE TO WHICH EMBEDDED GALVANIC ANODES WILL BE
THE ITEM "DEFORMED STEEL BARS - HDG".
REQUIREMENTS. THE COST OF FURNISHING AND PLACING THIS REINFORCEMENT SHALL BE INCLUDED IN AND SHALL BE GALVANIZED TO THE REQUIREMENTS OF ASTM A767, CLASS 1, INCLUDING SUPPLEMENTAL GALVANIZED REINFORCEMENT (HDG) SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615, GRADE 60 ENCASEMENT SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION UNLESS NOTED OTHERWISE. HOT-DIP
: REINFORCEMENT FOR NEW RETAINING WALL AND NEW STORM DRAINAGE REINFORCEMENT
OTHERWISE.
: ALL REINFORCEMENT SHALL HAVE 2 INCHES COVER UNLESS DIMENSIONED CONCRETE COVER
OTHERWISE.
" UNLESS DIMENSIONED 4
3" x4
3: EXPOSED EDGES OF CONCRETE SHALL BE BEVELED EXPOSED EDGES
CAST-IN-PLACE STRUCTURE COMPONENTS:
: THE FOLLOWING PAY ITEMS AND CONCRETE CLASS ARE REQUIRED FORCONCRETE CLASSES
: THE USE OF REMAIN-IN-PLACE FORMS ON THIS STRUCTURE IS NOT ALLOWED.REMAIN-IN-PLACE FORMS
CONCRETE NOTES
89.8DOWNSTREAM DESIGN WATER SURFACE ELEV. (FT)
108.4UPSTREAM DESIGN WATER SURFACE ELEV. (FT)
105.7ADF ELEVATION (CALCULATED) (FT)
295DESIGN DISCHARGE (CFS)
50DESIGN FREQUENCY (YR)
0.36DRAINAGE AREA (SQ. MI.)
HYDRAULIC DATA - FREEMAN BROOK
SCOPE OF WORK
INSTALL FENCE; RESTORE ACCESS ROAD; INSTALL VEHICLE BARRIER GATE.14.
AND TEMPORARY EARTH RETAINING SYSTEM.
REMOVE TEMPORARY WATER HANDLING SYSTEM, TEMPORARY BYPASS PIPE/HOSE, 13.
CONSTRUCT RIPRAP BASIN AND LINE OF BOULDERS.12.
APPLY PENETRATING CONCRETE SEALER.11.
(SEE HIGHWAY PLANS).
INSTALL NEW STORM DRAINAGE MANHOLES, PIPES AND HEADWALLS 10.
CULVERT (SEE SANITARY SEWER SUBSET).
SANITARY SEWER MANHOLES AND SANITARY SEWER MAIN DOWNSTREAM OF
RECONSTRUCT SANITARY SEWER MANHOLE AT CULVERT OUTLET. INSTALL NEW 9.
CONSTRUCT CONCRETE RETAINING WALL.8.
DRAINAGE ENDWALL.
SANITARY SEWER OUTSIDE OF THE BOX CULVERT, AND REMOVE EXISTING STORM
REMOVE EXISTING SANITARY SEWER MAIN AND CONCRETE ENCASEMENT FOR THE 7.
REPAIR BOX CULVERT INVERT WITH CONCRETE.6.
HEADWALLS AS NECESSARY AND WHERE DIRECTED BY THE ENGINEER.
UNDERSIDE OF TOP SLAB, WINGWALLS, FOOTINGS, CUTOFF WALLS, AND
PERFORM CONCRETE REPAIRS TO BOX CULVERT SIDE WALLS, BOTTOM SLAB, 5.
WHERE DIRECTED BY THE ENGINEER.
PERFORM CRACK SEALING AND CURTAIN WALL SEALING AT BOX CULVERT WALLS 4.
SEDIMENT, DEBRIS AND BIOLOGICAL GROWTH TO FACILITATE REHABILITATION.
CLEAN INTERIOR OF EXISTING BOX CULVERT BY REMOVING AND DISPOSING ALL 3.
AND TEMPORARY EARTH RETAINING SYSTEM.
INSTALL TEMPORARY WATER HANDLING SYSTEM, TEMPORARY BYPASS PIPE/HOSE, 2.
CLEARING AND GRUBBING; CONSTRUCT ACCESS ROAD (SEE HIGHWAY PLANS)1.
SJH CEP
PCC04483CULVERT AND WINGWALL REPAIRSSURFACE REPAIR CONCRETE
PCC03340CULVERT BOTTOM SLABCONCRETE INVERT
PCC03340
STORM DRAINAGE ENCASEMENT
RETAINING WALL,
ABUTMENT AND WALL CONCRETE
PCC CLASSBRIDGE COMPONENTITEM
#0610001A - “DRILLING HOLES AND BONDING ANCHORS.”
INSTALL ANCHORS, AND INSPECT AND TEST THE ANCHORS SHALL BE PAID FOR UNDER THE ITEM
THE WORK TO FURNISH THE ANCHORS AND ADHESIVE BONDING MATERIAL, DRILL HOLES, 7.
UNLESS OTHERWISE SPECIFIED, THE ENGINEER SHALL RANDOMLY SELECT THE ANCHORS TO BE TESTED.
TABULATED PROOF LOAD:
DETAILS THE MINIMUM NUMBER OF ANCHORS AT EACH LOCATION TO BE FIELD TESTED TO THE
PROCEDURES AND INSTALLED ADHESIVE BONDED ANCHOR STRENGTH. THE FOLLOWING TABLE
THE ANCHOR SHALL BE FIELD TESTED UNDER A PROOF TEST LOAD TO VERIFY THE INSTALLATION 6.
FILLED WITH ADHESIVE BONDING MATERIAL OR NON-SHRINK GROUT.
EXISTING REINFORCEMENT IS NOT PERMITTED. ABANDONED HOLES SHALL BE COMPLETELY
MAINTAINING REQUIRED CONCRETE COVER. THE USE OF CORE DRILLING THROUGH THE
WHEN DRILLING HOLES, IF EXISTING REINFORCEMENT IS ENCOUNTERED, RELOCATE HOLE 5.
ANCHOR CATEGORY OF THE ADHESIVE BONDING MATERIAL SHALL BE AT LEAST CATEGORY 2.
OF 1.00 KSI OR GREATER IN DRY, CRACKED CONCRETE AT TEMPERATURE RANGE A. THE
THE ADHESIVE BONDING MATERIAL SHALL HAVE A MINIMUM CHARACTERISTIC BOND STRESS 4.
"CONCRETE NOTES" ON THIS SHEET.
THE ANCHORS SHALL CONFORM TO THE "REINFORCEMENT" REQUIREMENTS UNDER 3.
ANCHORS WAS 3.732 KSI.
THE COMPRESSIVE STRENGTH OF THE EXISTING BEDROCK IN THE DESIGN OF BONDING ROCK 2.
BONDED ANCHORS WAS 2.5 KSI.
THE COMPRESSIVE STRENGTH OF THE EXISTING CONCRETE IN THE DESIGN OF ADHESIVE 1.
ADHESIVE BONDED ANCHOR NOTES:
35.553#8 ANCHORS
WALL ROCK ANCHORS
#8 BARS - RETAINING
3.463#4 ANCHORS
INTERIOR WALL REPAIRS
#4 BARS - CULVERT
(KIPS)
TEST LOAD
PROOF
TO BE TESTED
ANCHORS
MIN. NUMBER OF
DESCRIPTION
ANCHOR
LOCATION
04.03
K:
Clough, Harbour & Associates, LLP
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-04
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_04_Boring_Logs.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
BORING LOGS
TRANSPORTATION
SJH CEP 04.04
K:
Clough, Harbour & Associates, LLP
(OW)
B-3 B-2
FND
CHD
WOOD BEAM RAIL
CONC. CURB
CONC. CURB
WOOD BEAM RAIL
CONC. CURB
CONC. CURB
WOOD BEAM RAIL
CP-4
CHAIN LINK FENCECHAIN LINK FENCE
S T R
U C
T U
R E
' X ' B
O X C
U L
V E
R T
WOOD BEAM RAIL
20'
88'
86'
90'
101+00 102+00 103+00
201+00 202+00 203+00
220+00 221+00
13+00 14+00
STONE WALL
STONE WALL
" R
C P
" R
C P
" R
C P
" R
C P
S A
N
E
N C
A S E
D
IN
C
O N
C
" S
A N . S
E W
E R
SHEET 1A
ROW MAP 138-180E
ROW MAP 138-180E SHEET 1A ROW MAP 138-180E SHEET 2A
" R
C P U
N D
E R
D R
A
IN
" S
A N
S A
N
" S
A N
" S
A N . S
E W
E R
E
N C
A S E
D
IN
C
O N
C
OHW
(2011)
C O
O R
D
IN
A T E G
R
ID
AD
O
N N
E C
T
IC
T
20' 40'
1" = 20'
HORIZONTAL SCALE
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-05
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_05_Water_Handling.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
DESIGNER/DRAFTER: CHECKED BY: WATER HANDLING PLAN
OF CONSTRUCTION AND
SUGGESTED SEQUENCE
TRANSPORTATION
100 YR
MIN. TOP EL. UPSTREAM = 107
COMPLETED MANUALLY (SEE CONSTRUCTION NOTE 5)
TEMPORARY WATER-HANDLING - COFFERDAM TO BE
(DOWNSTREAM)
MIN. TOP EL. = 86
-HANDLING - COFFERDAM
TEMPORARY WATER
BYPASS PIPE
42" DIA. TEMPORARY
FR
EE
M A
N
BRO
O
K
F R
E E
M A
B R
O O
K
ROUTE 15
ROUTE 15
NORTHBOUND
SOUTHBOUND
EXISTING BRIDGE NO. 02150 TO REMAIN
SEDIMENTATION CONTROL SYSTEM (TYP.)
PROPOSED SLOPE LIMITS (TYP.)
TEMP. STORM DRAINAGE BYPASS HOSE
(TYP.) (SEE SANITARY SEWER SUBSET)
SANITARY SEWER MAIN AND MANHOLE
REMOVE EXISTING ENDWALL
(SEE HIGHWAY SUBSET)
STORM DRAINAGE MANHOLE
(SEE HIGHWAY SUBSET)
STORM DRAINAGE PIPE (TYP.)
ACCESS ROAD
(SEE HIGHWAY SUBSET)
STORM DRAINAGE CATCH BASIN
HIGHWAY SUBSET)
ENDWALL (SEE
STATE/FEDERAL WETLANDS (TYP.)
LIMITS (MAPPED)
100-YEAR FLOODPLAIN
BYPASS HOSE
TEMPORARY STORM DRAINAGE
RUNOFF AS NECESSARY
PUMP STORM WATER
TEMPORARY DEWATERING BASIN (TYP.)
MIN. TOP EL. 100
HANDLING - COFFERDAM
TEMPORARY WATER-
CRUSHED STONE
OVER 12" DEPTH OF 2"
36" STANDARD RIPRAP
MATERIAL WASH-IN TO
NATURAL STREAMBED
WITH TOP EL. 88 FT
2.5 - 3.5 FT BOULDERS
INSTALL A LINE OF
TAKING LINE
CONSTRUCTION EASEMENT
LIMITS OF PROPOSED
FENCE
VISIBILITY
HIGH
FLOOD (CALCULATED)
EXISTING 100-YEAR
PUMP STORM WATER RUNOFF AS NECESSARY
UNNAMED WATERCOURSE 3
WETLAND C
WETLAND A
WETLAND B
UNNAMED
WATERCOURSE 2
(SEE SANITARY SEWER SUBSET)
RECONSTRUCT SANITARY SEWER MANHOLE
CLEAN INTERIOR OF EXISTING BOX CULVERT
CONCRETE RETAINING WALL NO 101
RETAINING SYSTEM AS NECESSARY (TYP.)
APPROX. 72 L.F. OF TEMPORARY EARTH
CRUSHED STONE
OVER 12" DEPTH OF 2"
36" STANDARD RIPRAP
RIPRAP SWALE
18" INTERMEDIATE
RIPRAP APRON
18" INTERMEDIATE
12" MODIFIED RIPRAP
LEDGE IN CHANNEL
AREA OF EXPOSED
LEGEND
EDGE OF WATER
ORDINARY HIGH WATER
STATE/FEDERAL WETLANDS
TEMPORARY WATER-HANDLING - COFFERDAM
(SEE CONSTRUCTION NOTE 6)
NON-DRIVEN TEMPORARY EARTH RETAINING SYSTEM
(APPROXIMATE LOCATION)
SEDIMENTATION CONTROL SYSTEM
FLOW
SECTION VIEW
(SEE TEMP. HYDRAULIC TABLE)
TEMP. WATER SURFACE ELEV.
PLASTIC SEAL LINER
MIN. TOP EL. DOWNSTREAM = 86
MIN. TOP EL. UPSTREAM = 107
TEMPORARY WATER-HANDLING - COFFERDAM
BYPASS PIPE
TEMPORARY
(SANDBAGS)
WATER-HANDLING - COFFERDAM CONCEPT
NOT TO SCALE
THROUGH THE WORK AREA.
MINIMIZES NEGATIVE IMPACTS AND SAFELY CONVEYS LARGER FLOWS
FLOWS, PROVIDED THAT THIS INCLUDES A CONTINGENCY PLAN, WHICH
CONSTRUCTION WATER HANDLING PLAN WITH LOWER PUMPING
WEATHER CONDITIONS, THE ENGINEER MAY APPROVE A
BASED UPON FIELD CONDITIONS, WORK DURATION, AND EXPECTED 6.
AREAS SHOWN ON THE WETLAND IMPACT SHEET OF THE PERMIT PLANS.
ALL CONSTRUCTION RELATED ACTIVITIES SHALL NOT EXCEED IMPACT 5.
ENGINEER FOR APPROVAL.
HANDLING SYSTEM SHALL BE SUBMITTED BY THE CONTRACTOR TO THE
SPECIFICALLY PROHIBITED. A MEANS AND METHOD FOR WATER
"HANDLING WATER TYPICAL SCHEMATICS" MAY BE UTILIZED UNLESS
ANY WATER HANDLING SCHEME DEPICTED WITHIN THE DEPARTMENT'S 4.
ENVIRONMENTAL PERMIT(S).
ACTIVITY AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE
CONSTRUCTION AREA, SHALL BE ABLE TO SUPPORT CONSTRUCTION
SAFELY CONVEY WATER FLOWS CONTINUOUSLY THROUGH THE
APPROVED SYSTEM THAT THE CONTRACTOR ELECTS TO USE WHICH WILL
TEMPORARY WATER HANDLING SYSTEM SHALL CONSIST OF AN 3.
(CALCUATLED) ELEVATION.
THE WETLAND LIMITS AND ABOVE THE EXISTING 100-YEAR FLOOD
TEMPORARY DEWATERING BASINS SHALL BE ESTABLISHED OUTSIDE OF 2.
WATER HANDLING SYSTEM AS REQUIRED DURING CONSTRUCTION.
THE CONTRACTOR SHALL MAINTAIN WATER THROUGH THE TEMPORARY 1.
LOW FLOW.
UNCONFINED INSTREAM WORK SHALL BE DONE DURING PERIODS OF -
MINIMIZED TO THE EXTENT POSSIBLE.
DISTURBED AREAS AND THE DURATION OF DISTURBANCE SHALL BE -
TO MINIMIZE TURBIDITY/SEDIMENT TRANSPORT DOWNSTREAM.
BEST MANAGEMENT PRACTICE SHALL BE UTILIZED WHEREVER POSSIBLE -
FOR TEMPORARY AND PERMANENT IMPACT.
DISTURBANCE SHALL BE LIMITED TO AREAS THAT HAVE BEEN APPROVED -
ALL UNCONFINED IN-WATER WORK SHALL BE MINOR IN NATURE.-
PROPOSED SCHEDULE FOR WORK OPERATIONS.-
UNCONFINED IN-WATER WORK WITH CONSIDERATION OF THE FOLLOWING:
THE DEPARTMENT WILL REVIEW AND MAY APPROVE THE METHODS OF 2.
THE CONDITION SHALL APPLY TO PROJECTS IN NON-COASTAL WATERS.
UNLESS OTHERWISE INCLUDED AS A SPECIAL PROVISION OF THE LICENSE,
RESTRICTED TO THE PERIOD FROM JUNE 1 TO SEPTEMBER 30, INCLUSIVE,
ANY UNCONFINED IN-STREAM WORK WITHIN THE WATERCOURSE SHALL BE 1.
UNDER THE ITEM "TEMPORARY EARTH RETAINING SYSTEM" (T.E.R.S.)
DRIVEN TEMPORARY EARTH RETAINING SYSTEM WILL BE PAID FOR
METHOD FOR SUPPORTING THE LIMITS OF EXCAVATION. NON-
CONTRACTOR IS RESPONSIBLE FOR DEVELOPING A MEANS AND
CULVERT AS NECESSARY TO FACILITATE THE WORK. THE
INSTALLED IN THE VICINITY OF THE EXISTING CONCRETE BOX
NON-DRIVEN TEMPORARY EARTH RETAINING SYSTEM MAY BE 6.
THROUGHOUT THE INTERIOR OF THE CULVERT.
THE BOX CULVERT TO PERFORM WORK AT THE INLET AND
METHODS FOR TRANSPORTING MATERIALS AND TOOLS THROUGH
CONTRACTOR SHALL BE REQUIRED TO PROVIDE MEANS AND 5.
INFORMATION.
SANITARY SEWER SUBSET DRAWING NO. SAN-03 FOR ADDITIONAL
CONNECTION TO EXISTING SANITARY SEWER MANHOLES. SEE
RECONSTRUCTION OF THE SANITARY SEWER ENCASEMENT AND
THE CONTRACTOR SHALL COORDINATE WITH THE TOWN DURING 4.
UNDER "HANDLING WATER".
COFFERDAM AND TEMPORARY BYPASS PIPE SHALL BE PAID FOR
WORK ASSOCIATED WITH THE TEMPORARY WATER-HANDLING-3.
FOR ADDITIONAL INFORMATION.
ITEM "WATER POLLUTION CONTROL". SEE SPECIAL PROVISIONS
DRAINAGE. WORK SHALL BE PAID FOR UNDER THE CONTRACT
CONSTRUCTION OPERATIONS WHILE MAINTAINING SURFACE
THE STORM WATER TO PREVENT WASHOUTS DURING
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTROLLING 2.
LIMITS NECESSARY TO PERFORM THE CONTRACT WORK.
THE CONTRACTOR IS RESPONSIBLE FOR ACTUAL LOCATION AND 1.
CONSTRUCTION NOTES:
SUGGESTED SEQUENCE OF CONSTRUCTION:
UNCONFINED IN-STREAM WORK BMP NOTES:
WATER HANDLING NOTES:
18" INTERMEDIATE RIPRAP
SCALE: 1"=20'
PLAN
EROSION CONTROL MATTING(CALCULATED)
EXISTING 100-YEAR FLOOD
100 YEAR FLOODPLAIN LIMITS (MAPPED)
SJH CEP
12" DEPTH OF 2" CRUSHED STONE
36" STANDARD RIPRAP OVER
OVER 12" DEPTH OF 2" CRUSHED STONE
WASH-IN TO 36" STANDARD RIPRAP
NATURAL STREAMBED MATERIAL
REMOVE E&S CONTROLS UPON FINAL STABILIZATION.14.
RESTORE SITE; PERFORM FINAL GRADING AND SEEDING.13.
REMOVE TEMPORARY WATER HANDLING.12.
REMOVE TEMPORARY EARTH RETAINING SYSTEM.11.
CONSTRUCT RIPRAP BASIN AND LINE OF BOULDERS.10.
CONSTRUCT CONCRETE RETAINING WALL.9.
INSTALL DRAINAGE R.C. PIPE, ENCASEMENT, AND ENDWALL.8.
SUGGEST SEQUENCE OF CONSTRUCTION NOTES).
NEW SANITARY SEWER (SEE DRAWING NO. SAN-03 FOR ADDITIONAL
INSTALL TEMPORARY SANITARY SEWER BYPASS SYSTEM AND INSTALL 7.
AND INVERT REPAIRS.
AND CURTAIN WALL SEALING REPAIRS; PERFORM CONCRETE SURFACE
CLEAN INTERIOR OF EXISTING BOX CULVERT; PERFORM CRACK SEALING 6.
INSTALL DRAINAGE MANHOLE.5.
INSTALL WATER HANDLING.4.
INSTALL TEMPORARY EARTH RETAINING SYSTEM (T.E.R.S.) AS NECESSARY.
CONSTRUCT PERMANENT ACCESS ROAD AND FRENCH MATTRESS; 3.
PERFORM CLEARING AND GRUBBING.2.
INSTALL EROSION AND SEDIMENTATION (E&S) CONTROLS.1.
84.6 FT
SURFACE ELEVATION DOWNSTREAM
2-YEAR EXISTING WATER
104.0 FT
SURFACE ELEVATION UPSTREAM
2-YEAR EXISTING WATER
84.9 FT
SURFACE ELEVATION DOWNSTREAM
2-YEAR TEMPORARY WATER
105.6 FT
SURFACE ELEVATION UPSTREAM
2-YEAR TEMPORARY WATER
55 CFS
= 2-YEAR FREQUENCY
TEMPORARY DESIGN DISCHARGE
GRAVITY FLOW BYPASS PIPE
5.2 CFS
= 4 x AVERAGE SPRING FLOW
TEMPORARY DESIGN DISCHARGE
LOW FLOW PUMPING
55 CFS2-YEAR FREQUENCY DISCHARGE
1.3 CFSAVERAGE SPRING FLOW
0.7 CFSAVERAGE DAILY FLOW
*TEMPORARY HYDRAULIC DATA
HIGH VISIBILITY FENCE
ENDANGERED SPECIES NOTE:
GREATER FROM APRIL 15 TO OCTOBER 31
OR REMOVAL OF TREES WITH 3" DBH OR
TRI-COLORED BAT - NO TRIMMING, CUTTING,
CHAIN LINK FENCE
12" MODIFIED RIPRAP
T.E.R.S.
NOT TO SCALE
PAYMENT FOR T.E.R.S.
MEASUREMENT OF
VERTICAL LIMITS
V A
R
IE
S
EXCAVATION
BOTTOM OF
OF GRADE
APPROX. TOP
T.E.R.S.
04.05
K:
Clough, Harbour & Associates, LLP
APPROXIMATE TOP OF ROADWAY AT GUTTER LINE
EXISTING CONCRETE HEADWALL
EXISTING CONCRETE BOX CULVERT
APPROX. EXIST. GRADE
REMOVE EXISTING SANITARY SEWER MAIN
OHW EL. 87.2
EL. 89.8
50-YEAR DESIGN
WINGWALL (TYP.)
EXISTING CONC.
WW2B
WW1B
SLOPED EMBANKMENT
MERRITT PARKWAY TIMBER GUIDE RAIL
50-YEAR EXISTING EL. 87.4
(CALCULATED) EL. 87.5
EXISTING 100-YEAR FLOOD
CONCRETE RETAINING WALL
HEADWALL AS REQUIRED (TYP.)
FOOTING, CUTOFF WALL, AND
TO BOX CULVERT, WINGWALLS,
PERFORM CONCRETE REPAIRS
APPROXIMATE FINISHED GRADE (RIPRAP BASIN)
FL = 89.50
APPROXIMATE FINISHED GRADE BEHIND WALL
INV. = 92.47
FOR STORM DRAINAGE
CONCRETE ENCASEMENT
(LEVEL)
EL. 94.9
EL. 94.9±
4' CHAIN LINK FENCE (HIGHWAY ITEM)
APPROXIMATE INV. EL. 93.7
INSTALL WEEP HOLE FILTER SYSTEM
SANITARY MANHOLE
REMOVE EXISTING
10'-0"
EL. 93.5±
CONCRETE LINER
4" THICK CAST-IN-PLACE
REPAIR CULVERT INVERT WITH
15" POLYVINYL CHLORIDE PIPE (SANITARY SEWER)
(SANITARY SEWER)
MANHOLE
APPROXIMATE INV. EL. 95.4
INSTALL WEEP HOLE FILTER SYSTEM
CORNER
JOINT
CONTRACTION
(TYP.)
RETAINING WALL
WEEPHOLE IN
EXISTING CONCRETE HEADWALL
EXISTING CONCRETE BOX CULVERT
WW1A
WW2A
EXISTING 15" DIA. SANITARY SEWER
APPROXIMATE TOP OF ROADWAY AT GUTTER LINE MERRITT PARKWAY TIMBER GUIDE RAIL
50-YEAR EXISTING EL. 108.4
CONCRETE ENCASEMENT AS REQUIRED
PERFORM SURFACE REPAIRS AT EXISTING
WINGWALL (TYP.)
EXISTING CONCRETE
SLOPED EMBANKMENT
50-YEAR DESIGN EL. 108.4
(TYP.)
EXISTING GRADE
APPROXIMATE
AS REQUIRED (TYP.)
CUTOFF WALL, AND HEADWALL
TO BOX CULVERT, WINGWALLS,
PERFORM CONCRETE REPAIRS
OHW EL. 106.9
FOR DETAILS)
(SEE DRAWING S-11
INVERT REPAIR
4" THICK CONCRETE
(CALCULATED) EL. 108.7
100-YEAR FLOOD ELEVEATION
PROPOSED INV. = 102.13
FRONT OF CULVERT INLET
MATERIAL (4" MIN.) IN
SUPPLEMENTAL STREAMBED
10'-0"
EXISTING CONCRETE PAD
2'-0"±
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-06
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_06_Section_Elevations.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
AND ELEVATIONS
LONGITUDINAL SECTION
TRANSPORTATION
3' SHDR. 11' 11' 20'
1' SHDR.
11'11'
3' SHDR.
14'
5' SHDR.
SOUTHBOUND
NORTHBOUND
4.8%
CLEAN INTERIOR OF EXISTING CONCRETE BOX CULVERT
CONCRETE BOX CULVERT (TO REMAIN)
201'-4" LF - EXISTING 10' WIDE X 8' HIGH
50-YEAR EXISTING EL. 87.4
(TYP.)
TIMBER GUIDE RAIL
MERRITT PARKWAY
LANE LANE
MEDIAN
GRASS LANE LANE
RAMP
EXIT
APPROXIMATE EXISTING SLOPE EMBANKMENT (TYP.)
APPROXIMATE EXISTING GRADE (TYP.)
ROUTE 15 ROUTE 15
OHW EL. 87.2
ON 12" DEPTH OF 2" CRUSHED STONE
LINE OF 2.5 - 3.5 FT ROUNDED BOULDERS
OHW EL. 106.9
(CALCULATED) EL. 108.7
100-YR FLOOD ELEVATION
50-YEAR EXISTING EL. 108.4
50-YEAR DESIGN EL. 108.4
50-YEAR DESIGN EL. 89.8
(TYP.)
FOOTINGS, CUTOFF WALLS, AND HEADWALLS, AS REQUIRED
BOTTOM SLAB, UNDERSIDE OF TOP SLAB, WINGWALLS,
PERFORM CONCRETE REPAIRS TO BOX CULVERT WALLS,
(RIPRAP BASIN)
APPROXIMATE FINISHED GRADE AT CENTERLINE OF CULVERT
(TO REMAIN) (TYP.)
EXISTING CONCRETE HEADWALL
RIPRAP OVER 12" DEPTH OF 2" CRUSHED STONE
NATURAL STREAMBED MATERIAL WASHED-IN TO 36" STANDARD
CONCRETE LINER
4" THICK CAST-IN-PLACE
REPAIR CULVERT INVERT WITH
EXISTING 100-YEAR FLOOD (CALCULATED) EL. 87.5
MATERIAL (4" MIN.)
SUPPLEMENTAL STREAMBED
POST-INSTALLED WEEP AND FILTER (TYP.)
APPROXIMATE LOCATION OF PROPOSED
OVER 12" DEPTH OF 2" CRUSHED STONE
WASHED-IN TO 36" STANDARD RIPRAP
NATURAL STREAMBED MATERIAL
8.5'±
LONGITUDINAL SECTION
SCALE: 1" = 20'
INLET ELEVATION
SCALE: 1/4"=1'-0"
OUTLET ELEVATION
SCALE: 1/4"=1'-0"
SCALE AS NOTED
CEP
NOTES:
SEE DRAWING NO. S-14 FOR CONCRETE SEALER LIMITS.5.
SEE DRAWING NO. S-13 FOR RETAINING WALL DETAILS.4.
SEE DRAWING NO. S-12 FOR RETAINING WALL PLAN AND ELEVATION.3.
SEE DRAWING NO. S-11 FOR CULVERT INVERT REPAIR DETAILS.3.
SEE DRAWING NO. S-08 THROUGH S-10 FOR CULVERT REPAIR DETAILS.2.
PROVISION "CLEAN EXISTING CULVERT - GREATER THAN 42" DIAMETER".
MEANS AND METHODS AS APPROVED BY THE ENGINEER. SEE SPECIAL
VEGETATION AND BIOLOGICAL GROWTH FROM WITHIN THE STRUCTURE USING
INCLUDE REMOVAL, COLLECTION AND DISPOSAL OF SEDIMENT, DEBRIS,
WITH CLEANING AND PREPARING CONCRETE SURFACES FOR REPAIRS, IS TO
GENERAL CLEANING OF EXISTING BOX CULVERT, THAT IS NOT ASSOCIATED 1.
SJH 04.06
K:
Clough, Harbour & Associates, LLP
201'-4"±
201'-4"±
201'-4"±
PROJECT TITLE: PROJECT NO.: DRAWING NO.:
SHEET NO.:
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-07
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_07_Existing_Structure_Conditions.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
CONDITIONS
EXISTING STRUCTURE
TRANSPORTATION
WW1B
6"L SPALL
WW2B
EXISTING SANITARY SEWER PIPE TO BE REMOVED AND REPLACED
UNDERMINING AT WINGWALL FOOTING
UNDERMINING AT CUTOFF WALL
EXISTING CUTOFF WALL EXPOSED FL x FH
UNDERMINING AT CONCRETE ENCASEMENT
EXISTING SANITARY MANHOLE TO BE REMOVED AND REPLACED 30"L x 8"H x 2"D SPALL
1'x1' HOLLOW AREA
REMAIN
MANHOLE TO
EXISTING SANITARY
OHW EL. 87.2
50-YEAR EXISTING EL. 87.4
100-YEAR FLOOD ELEVATION (CALCULATED) EL. 87.5
10'
GRADE (TYP.)
APPROX. EXISTING
UTILITY PIPE 16'L x 3'W x UP TO 1'H
SPALL IN UTILITY ENCASEMENT ABOVE
ACTIVE LEAKAGE
CONCRETE WITH
UP TO 6"x6" SOFT
WW2A
WW1A
"D SPALL4
3" DIA. x
(TYP.)
EXISTING GRADE
APPROXIMATE
10'
OHW EL. 106.9
50-YEAR EXISTING EL. 108.4
(CALCULATED) EL. 108.7
100-YEAR FLOOD ELEVATION
FACE OF SANITARY SEWER ENCASEMENT
SEVERE SCALE AND ABRASION AT OUTSIDE
EXISTING CONCRETE PAD
FLOW
FLOW
WALL NO. 2
WALL NO. 1
FLOW
FOR SANITARY SEWER
EXISTING CONCRETE ENCASEMENT
BOTTOM SLAB
TOP SLAB
TOP SLAB
BOTTOM SLAB
JOINT 1
POUR
JOINT 13
POUR
JOINT 7
CONSTRUCTION
JOINT 1
POUR
JOINT 7
CONSTRUCTION
JOINT 13
POUR
JOINT 13
POUR
JOINT 7
CONSTRUCTION
JOINT 1
POUR
SPALLS (A.L.)
(3) UP TO 1'H x 9"W x 1"D
24"W x 15"H x UP TO 4"D SPALL
27"W x 7"H x 2"D SPALL (A.L.)
38"W x 9"H x 3"D SPALL (A.L.)
SPALL (A.L.)
15"W x 8"H x 3.5"D
WALL NO. 2
SCALE: 1" = 10'
TOP SLAB (REFLECTED VIEW)
SCALE: 1" = 10'
WALL NO. 1
JOINT 4
POUR
JOINT 10
POUR
JOINT 4
POUR
JOINT 10
POUR
JOINT 10
POUR
JOINT 4
POUR
(A.L.)
x 1"D SPALL x UP TO 3'W
UP TO 3'H
36"H x 4"W x 1"D SPALL (A.L.)
SPALL (A.L.)
7.5'W x 14"H x 6"D
SPALL (A.L.)
45"W x 8"H x 5"D
22"H x 2"W x 1"D SP
24"H x 2"W x 1"D SPALL
20"H x 6"W x 6"D SPALL (A.L.)
20"W x 4"H x 5"D SPALL (A.L.)
SPALL (A.L.)
27"H x 4.5"W x 1.5"D
3'L SHALLOW SPALL
(MOISTURE PRESENT)
26"H x 6"W x 1"D SPALL
SPALLS
(3) 8" DIA. x UP TO 1"D
SCALE: 1" = 10'
HEAVY SCALE
OUTLET
OUTLET
OUTLETINTLET
INTLET
INTLET
SPALL (A.L.)
24"H x 6"W x 1"D
24"H x 12"W HOLLOW AREA
(A.L.)
(2) 12"L x 1.5"D OPEN JOINTS
COVER
SHALLOW
6"H x 6"W x 5"D SPALL (A.L.)
(A.L.)
OPEN JOINT
(A.L.)
OPEN JOINT
HEAVY SCALE
(A.L.)
OPEN JOINT
(3) OPEN JOINTS (A.L.)
(PAST LEAKAGE)
26"H x 4"W x 1"D SPALL
OF PAST LEAKAGE
WITH EVIDENCE
RANDOM HOLES
CONCRETE (A.L.)
12"H x 24"W SOFT
= EFFLORESCENCE PRESENT*
= FULL WIDTHFW
= FULL LENGTHFL
= FULL HEIGHTFH
= EXPOSED REBARER
= ACTIVE LEAKAGEA.L.
SPALL WITH EXPOSED REBAR
SPALL AREA
HOLLOW, OR SCALE, AREA
LIMITS OF DEMOLITION
W A
L L
N O
W A
L L
N O
TOP SLAB
BOTTOM SLAB
LOOKING UPSTREAM
BOX CULVERT DIAGRAM
NOTES:
UP TO FULL WIDTH
AREAS OF SCALE NOTED ON WW2B FOOTING AND WINGWALL UP TO 6'L x -
LENGTH x FULL WIDTH.
- AREAS OF MEDIUM TO HEAVY SCALE ALONG THE CULVERT INVERT FOR FULL
FULL LENGTH x 3" HIGH x 1.5" DEEP.
- SCALE ALONG BOTTOM OF SANITARY SEWER CONCRETE ENCASEMENT FOR
PRESENT AT RANDOM AREAS OF CRACKING.
AREAS OF MAP CRACKING IN TOP SLAB UNDERSIDE THROUGHOUT. MOISTURE
- HAIRLINE CRACKS, SOME OPEN TO 1/16"W, ARE PRESENT THROUGHOUT.
AND SEDIMENT ACCUMULATION.
- SPALLS AND SCALING IN BOTTOM OF WALL NO. 2 EXHIBIT WATER LEAKAGE
INCLUDE, BUT ARE NOT LIMITED TO:
ADDITIONAL CONCRETE DEFICIENCIES NOTED IN THE INSPECTION REPORT 5.
BROUGHT TO THE ATTENTION OF THE ENGINEER.
ANY CRACKS OVER 0.02" WIDE IDENTIFIED DURING CONSTRUCTION SHALL BE
BASED ON FIELD OBSERVATIONS, NO STRUCTURAL CRACKS WERE OBSERVED. 4.
REPAIR DETAILS.
DRAWING NO. S-11 "CULVERT REPAIR DETAILS IV" FOR CONCRETE INVERT
EXISTING CONCRETE BOX CULVERT BOTTOM SLAB NOT SHOWN. SEE 3.
INSTALLED WEEP HOLE WITH FILTER DETAIL.
SEE DRAWING NOS. S-08 THRU S-11 FOR CULVERT REPAIR DETAILS AND POST-2.
PERFORMED ONLY AFTER LIMITS ARE DETERMINED BY THE ENGINEER.
PERFORMS REQUIRED REPAIR WORK. CULVERT REPAIRS SHALL BE
ENGINEER AND THE CONTRACTOR IN THE FIELD BEFORE CONTRACTOR
ONLY. ACTUAL LIMITS AND TYPES OF REPAIRS SHALL BE IDENTIFIED BY THE
INFORMATION SHOWN ON THIS SHEET IS FOR INFORMATIONAL PURPOSES
09/11/2024 AND FIELD VERIFICATION BY CHA ON 10/24/2024. THE
APPROXIMATE BASED ON THE CTDOT BRIDGE INSPECTION REPORT DATED
LOCATIONS AND LIMITS OF DETERIORATED CONCRETE SHOWN ARE 1.
CONCRETE DETERIORATION LEGEND
OUTLET ELEVATION
SCALE: 1/4"=1'-0"
INLET ELEVATION
SCALE: 1/4"=1'-0"
SCALE AS NOTED
SEWER
ENCASED
EXISTING
NOT TO SCALE
THE EXISTING SCOUR HOLE.
DOWNSTREAM OF CULVERT WITHIN
IN OUTLET ELEVATION ARE LOCATED
NOTE: WATER ELEVATIONS SHOWN
SJH CEP 04.07
K:
Clough, Harbour & Associates, LLP
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-08
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_08_Culvert_Repair_Details_1.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
CULVERT REPAIR DETAILS I
TRANSPORTATION
L V
E R
T W
A L
L
C U
L V
E R
T W
A L
L
DETAILS - INJECTION CRACK SEALING FOR ACTIVE LEAKAGE
NOT TO SCALE
EXISTING STEEL REINFORCEMENT
CONCRETE BOX CULVERT
INSIDE FACE OF EXISTING REINFORCED
FLEXIBLE RESIN CRACK INJECTION
ALTERNATE EACH SIDE OF CRACK
MANUFACTURER RECOMMENDATIONS.
DRILL HOLE AT 45° TO THE SURFACE PER
6"±
MOISTURE/LEAKAGE
CRACK WITH ACTIVE
MOISTURE/LEAKAGE
CRACK WITH ACTIVE
EACH SIDE OF CRACK
RECOMMENDATIONS. ALTERNATE
DRILL HOLE PER MANUFACTURER
OUTSIDE FACE OF BOX CULVERT
EXPANDED RESIN ALONG CRACK AT
(TYP.)
INJECTION PORT
(TYP.)
INJECTION PORT
REINFORCED CONCRETE WALL
INSIDE FACE OF EXISTING
INJECTION PORT IS REMOVED
REPAIR HOLE WITH MORTAR AFTER
REINFORCED CONCRETE BOX CULVERT
OUTSIDE FACE OF EXISTING BACKFILL
PLAN SECTION ELEVATION
DETAILS - INJECTION CURTAIN WALL SEALING FOR ACTIVE LEAKAGE
NOT TO SCALE
EXISTING STEEL REINFORCEMENT
CONCRETE BOX CULVERT
INSIDE FACE OF EXISTING REINFORCED
FLEXIBLE RESIN CRACK INJECTION
ALTERNATE EACH SIDE OF CRACK
PER MANUFACTURER RECOMMENDATIONS.
DRILL HOLE PERPENDICULAR TO THE SURFACE
MOISTURE/LEAKAGE
CRACK WITH ACTIVE
(TYP.)
MOISTURE/LEAKAGE
CRACK WITH ACTIVE
MANUFACTURER RECOMMENDATIONS
SPACING AND DRILL HOLES PER
OUTSIDE FACE OF BOX CULVERT
EXPANDED RESIN ALONG
(TYP.)
INJECTION PORT
(TYP.)
INJECTION PORT
REINFORCED CONCRETE WALL
INSIDE FACE OF EXISTING
INJECTION PORT IS REMOVED
REPAIR HOLE WITH MORTAR AFTER
BOX CULVERT
REINFORCED CONCRETE
OUTSIDE FACE OF EXISTING
BACKFILL
PLAN SECTION ELEVATION
S P
A C
IN
G
P E
R M
A N
U F
A C
T U
R E
E C
O M
M E
N D
A T
IO
S
6"± FROM CRACK
APPROXIMATELY
LOCATE PORT
NOTES:
1. INJECTION CRACK SEALING IS INTENDED TO BE USED AT ISOLATED
CRACKS. INJECTION FOR CURTAIN WALL SEALING IS TO BE USED WHERE
MULTIPLE CRACKS MAKE IT DIFFICULT TO SEAL CRACKS INDIVIDUALLY.
SEE REPAIR SEQUENCE FOR ADDITIONAL INFORMATION.
2.LOCATE REINFORCING BEFORE DRILLING TO AVOID DRILLING THROUGH
REINFORCING BARS.
FOR "FLEXIBLE RESIN INJECTION - CURTAIN WALL SEALING"
DASHED LINE IS THE PERIMETER OF THE AREA TO BE MEASURED
BY THE TECHINCAL REPRESENTATIVE
ENGINEER AND AS RECOMMENDED
INJECTION AS ORDERED BY THE
SEAL SURFACE OF CRACK PRIOR TO
CURTAIN WALL INJECTION
OVER THE SPECIFIED AREA (TYP.)
THEN PERFORM CURTAIN WALL INJECTION
INDIVIDUAL CRACKS 0.01" WIDE OR MORE,
PRIOR TO CURTAIN WALL INJECTING, INJECT
REPAIR SEQUENCE FOR STRUCTURE CONCRETE:
1. INJECTION CRACK SEALING:
PERFORM THIS WORK TO PREVENT LEAKAGE THROUGH INDIVIDUAL CRACKS WIDER
THAN 0.01". IF NECESSARY, SEAL EXPOSED SURFACE OF CRACKS WIDER THAN 0.01"
PRIOR TO INJECTION CRACK SEALING TO KEEP THE FLEXIBLE RESIN FROM SPILLING
OUT AS DIRECTED BY THE MANUFACTURERS TECHNICAL REPRESENTATIVE. INSTALL
INJECTION PORTS AT SURACE OF CONCRETE AND SEAL CRACKS PER THE
MANUFACTURER SPECIFICATIONS. ALLOW SUFFICIENT TIME FOR SEALANT TO SET
PRIOR TO INJECTING ADJACENT CRACKS AREAS.
2. INJECTION CURTAIN WALL SEALING:
AFTER INJECTION CRACK SEALING OF INDIVIDUAL CRACKS, PERFORM WORK FOR
INJECTION CURTAIN WALL SEALING. INSTALL INJECTION PORTS AT SURACE OF
CONCRETE AND SEAL OUTSIDE (BURIED) FACE OF WALL PER THE MANUFACTURER
SPECIFICATIONS UNTIL LEAKAGE STOPS FLOWING THROUGH CRACKS AND SPALLS.
ALLOW SUFFICIENT TIME FOR SEALANT TO SET PRIOR TO INJECTING ADJACENT
WALL AREAS, AND PRIOR TO REPAIRING CONCRETE.
3. SURFACE CONCRETE REPAIRS:
SEE DRAWING NOS. S-09 AND S-10 FOR DETAILS AND NOTES.
4. CONCRETE INVERT REPAIR:
SEE DRAWING NO. S-11 FOR DETAILS AND NOTES.
5. PENETRATING SEALER PROTECTIVE COMPOUND:
AFTER CRACK SEALING AND CONCRETE SURFACE REPAIRS ARE COMPLETE, APPLY
PENETRATING SEALER PROTECTIVE COMPOUND OVER MINOR CRACKS (LESS THAN
0.01" WIDE) AND THEN AGAIN OVER THE BROADER EXPOSED CONCRETE SURFACES
INCLUDING THE CRACKS PER THE MANUFACTURER SPECIFICATIONS.
6. WEEP HOLE WITH FILTER:
SEE DRAWING NO. S-11 FOR DETAIL AND NOTES.
NOTE: INSPECTION REPORTS SHOW PAST AND PRESENT LEAKAGE AT ONE
CULVERT WALL OVER AN APPROXIMATE HEIGHT OF 3' ABOVE THE INVERT
AND FOR AN APPROXIMATE LENGTH OF 100'. ACTUAL CURTAIN WALL
LIMITS WILL BE DETERMINED IN THE FIELD USING TEST HOLES AND OTHER
METHODS RECOMMENDED BY THE CURTAIN WALL CONTRACTOR AND
APPROVED BY THE ENGINEER.
SCALE AS NOTED
SJH CEP
CRACK REPAIR NOTES:
1. CONCRETE CRACKS THAT ARE DETERMINED TO BE OF NO STRUCTURAL CONCERN
AND SHOW NO SIGNS OF WATER LEAKING FROM THE CRACK AND ARE LESS THAN
0.02" WIDE SHALL BE SEALED WITH A PENETRATING SEALER AND SHALL NOT BE
REPAIRED BY INJECTION SEALING. THIS WORK SHALL BE INCLUDED FOR PAYMENT
UNDER ITEM #0819002A - "PENETRATING SEALER PROTECTIVE COMPOUND" AND
WILL NOT BE MEASURED SEPARATELY.
2. CRACKS WHICH ARE 0.01" WIDE OR LARGER ARE TO BE REPAIRED WITH FLEXIBLE
RESIN INJECTION SEALING AND SHALL BE PAID FOR UNDER ITEM #0601955A -
"FLEXIBLE RESIN INJECTION CRACK SEALING".
3. INJECTION CRACK REPAIR AND/OR CURTAIN WALL SEALING TO BE PERFORMED AT
CRACKS, CONSTRUCTION JOINTS AND SPALLS WHERE ACTIVE MOISTURE AND/OR
LEAKAGE IS PRESENT INSIDE THE BOX CULVERT. REPAIR CONCRETE SHALL NOT BE
PLACED IN AREAS OF DETERIORATED CONCRETE WHERE MOISTURE AND/OR
LEAKAGE IS PRESENT UNTIL THE FLEXIBLE RESIN INJECTION SEALANT HAS BEEN
INJECTED AND LEAKAGE STOPS TO ALLOW FOR A DRY WORKING ENVIRONMENT.
4. ALL WORK, TOOLS AND MATERIALS ASSOCIATED WITH CURTAIN WALL INJECTION
SHALL BE PAID FOR UNDER ITEM #0601956A - "FLEXIBLE RESIN INJECTION CURTAIN
WALL SEALING.
04.08
K:
Clough, Harbour & Associates, LLP
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-09
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_09_S_10_Culvert_Repair_Details_2_3.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
CULVERT REPAIR DETAILS II
TRANSPORTATION
1. MECHANICAL SPLICES ARE AN ACCEPTABLE
ALTERNATE IF APPROVED BY THE ENGINEER.
REINFORCEMENT SPLICE NOTE:
MAINTAIN EXISTING CONCRETE COVER (TYP.)
NEW REINFORCING BAR SIZE TO MATCH EXISTING.
REPAIR CONCRETE DETAILS
(TYP.)
EXISTING REINFORCEMENT
SURFACE
CONCRETE
EXISTING
REPAIR CONCRETE
WIRE AS REQUIRED
WITH ANCHORS AND TIE
TO SOUND CONCRETE
REINFORCING BARS AND
SECURED TO EXISTING
REINFORCEMENT*
WELDED WIRE
NOT TO SCALE
MORE LOSS OF DIAMETER
EXISTING BAR WITH 25% OR
16.0#7
16.0#6
16.0#5
16.0#4
LENGTH (IN)
MIN. SPLICE
BAR SIZE
SPLICE LENGTHS
OF 1" BEHIND REINFORCING BARS
REMOVE CONCRETE TO A MINIMUM
NOT TO SCALE
REINFORCEMENT SPLICE DETAIL
PERIMETER OF REPAIR AREA
SAWCUT 1" DEEP AROUND
EXISTING REINFORCEMENT (TYP.)
REINFORCEMENT
SECURE WELDED WIRE
CONCRETE AS REQUIRED TO
INSTALL ANCHORS INTO SOUND
(TYP.)
GALVANIC ANODE
PROPOSED EMBEDDED
SUPPLEMENTAL WELDED WIRE REINFORCEMENT*
REPAIR CONCRETE
BARS ARE AVAILABLE TO SECURE THE
REINFORCEMENT WHEN INSUFFICIENT
INSTALL 4"x4" - W2.9xW2.9 WELDED WIRE
SECTION - OVERHEAD SURFACE REPAIR
SECTION - VERTICAL SURFACE REPAIR
1" DEEP SAWCUT
SEE "EMBEDDED GALVANIC ANODE DETAILS" SHEET
PROPOSED EMBEDDED GALVANIC ANODE (TYP.)
2" MIN. COVER
AT ANODES (TYP.)
(TYP.)
REINFORCEMENT
EXISTING REPAIR CONCRETE
WIRE AS REQUIRED
WITH ANCHORS AND TIE
TO SOUND CONCRETE
REINFORCING BARS AND
SECURED TO EXISTING
REINFORCEMENT*
WELDED WIRE
ANODE DETAILS" SHEET
SEE "EMBEDDED GALVANIC
GALVANIC ANODE (TYP.)
PROPOSED EMBEDDED
AT ANODES (TYP.)
2" MIN. COVER
1" MIN. COVER
AT ANODES (TYP.)
EXISTING CONCRETE SURFACE
SECTION - VERTICAL SURFACE REPAIR WITH BUMP-OUT
REPAIR CONCRETE
45° BEVEL
(TYP.)
REINFORCEMENT
EXISTING
REMOVE CONCRETE TO
A MINIMUM OF 1" BEHIND
REINFORCING BARS
EXISTING CONCRETE SURFACE
WIRE AS REQUIRED
WITH ANCHORS AND TIE
TO SOUND CONCRETE
REINFORCING BARS AND
SECURED TO EXISTING
REINFORCEMENT*
WELDED WIRE
ANODE DETAILS" SHEET
SEE "EMBEDDED GALVANIC
GALVANIC ANODE (TYP.)
PROPOSED EMBEDDED
AT ANODES
2" MIN. COVER
1" MIN. COVER
1" MIN. COVER
1" MIN. COVER
AT ANODES (TYP.)
1" MIN. COVER
AT ANODES (TYP.)
1" MIN.
COVER
AT ANODES
(TYP.)
SECTION - DEPTH OF REMOVAL REQUIREMENTS
(TYP.)
REINFORCEMENT
EXISTING
1" DEEP SAWCUT (TYP.)
GALVANIC ANODE (TYP.)
PROPOSED EMBEDDED
REMOVE CONCRETE TO
A MINIMUM OF 1" BEHIND
REINFORCING BARS
EXISTING CONCRETE SURFACE
REMOVE CONCRETE
TO A MINIMUM OF 1"
BEHIND PROPOSED
GALVANIC ANODE
REMOVE CONCRETE TO
A MINIMUM OF 1" BEHIND
REINFORCING BARSAS REQUIRED
REMOVE SOUND CONCRETE
REMOVE DETERIORATED CONC.
(TYP.)
REMOVAL AND PAY LIMIT LINES
APPROX. LIMITS OF CONCRETE
SOUND CONCRETE TO 1" DEPTH
SAW CUT EDGES OF PATCH IN
REQUIRED*
REINFORCEMENT AS
WELDED WIRE
(TYP.)
REINFORCEMENT
EXISTING
BY THE ENGINEER
CONCRETE AS DETERMINED
LIMITS OF UNSOUND
(TYP.)
GALVANIC ANODE
PROPOSED EMBEDDED
ELEVATION
6" MIN.
NOTE 12)
REPAIR CONCRETE
(SEE CULVERT BARS
AND REINFORCING
* REINFORCEMENT
WELDED WIRE
2" MIN. COVER OVER
2" MIN. COVER OVER
WELDED WIRE
REINFORCEMENT* AND
REINFORCING BARS
(SEE CULVERT REPAIR
CONCRETE NOTE 13)
2" MIN. COVER OVER
WELDED WIRE
REINFORCEMENT* AND
REINFORCING BARS
JRH / JLPSJH
LIMITS OF
SECTION LOSS
SEE TABLE FOR MINIMUM SPLICE LENGTH.
THE BARS SHALL BE WIRED TOGETHER FOR
THE FULL LENGTH OF THE SPLICE (TYP.)
1. PRIOR TO REMOVAL OF EXISTING CONCRETE, THE CONTRACTOR SHALL PROVIDE ACCESS TO THE
ANTICIPATED WORK AREAS SO THAT THE INSPECTOR AND THE CONTRACTOR MAY TOGETHER
DETERMINE AND DELINEATE THE EXACT LIMITS AND LOCATIONS OF THE WORK. THE METHOD USED
TO DELINEATE AREAS OF CONCRETE TO BE REPAIRED SHALL NOT PERMANENTLY MARK THE
CONCRETE, LEAVE ANY RESIDUE AFTER REMOVAL, OR REQUIRE HARSH CHEMICALS TO REMOVE.
2. IF THE REMOVAL DEPTH EXCEEDS MORE THAN 1
2" BEHIND MAIN REINFORCEMENT, THE
CONTRACTOR SHALL CEASE REMOVAL OPERATIONS AND NOTIFY THE ENGINEER IMMEDIATELY.
3. REPAIR DETAILS APPLY TO SPALLED, SCALED, AND HOLLOW AREAS WHERE REQUIRED AND NOTED
ON DRAWINGS AND AS DIRECTED BY THE ENGINEER.
4. SURFACE PREPARATION, PROPORTIONING AND MIXING OF MATERIALS, APPLICATION OF
MATERIALS, AND REPAIR PROCEDURES SHALL BE IN ACCORDANCE WITH STANDARD
SPECIFICATION SECTION 6.01 "CONCRETE FOR STRUCTURES".
5. WELDED WIRE REINFORCEMENT USED IN REPAIR AREAS WILL NOT BE MEASURED FOR PAYMENT BUT
WILL BE INCLUDED IN THE COST UNDER ITEM #0601072 - "SURFACE REPAIR CONCRETE".
6. CORRODED, MISSING OR BROKEN REINFORCING STEEL SHALL BE REPLACED AND WILL BE
MEASURED FOR PAYMENT UNDER ITEM #0602000 - "DEFORMED STEEL BARS". BARS TO BE LEFT IN
PLACE THAT ARE DAMAGED BY THE CONTRACTOR SHALL BE REPLACED TO THE SATISFACTION OF
THE ENGINEER AND AT THE EXPENSE OF THE CONTRACTOR.
7. BONDING COMPOUND SHALL NOT BE USED PRIOR TO OR DURING THE PLACEMENT OF THE REPAIR
CONCRETE MATERIAL.
8. REPAIR CONCRETE MATERIAL SHALL BE CLASS PCC04483, OR APPROVED EQUAL.
9. THE SURFACE OF CONCRETE REPAIR AREAS SHALL MATCH THE SURFACE PROFILE OF EXISTING
CONCRETE SURFACES UNLESS NOTED OTHERWISE.
10. AREAS DISTURBED BY CONSTRUCTION SHALL BE RESTORED TO THEIR ORIGINAL CONDITION UNLESS
OTHERWISE NOTED OR AS DIRECTED BY THE ENGINEER AT NO ADDITIONAL COST TO CTDOT.
11. PENETRATING SEALER TO BE PAID FOR UNDER THE ITEM #0819002A - "PENETRATING SEALER
PROTECTIVE COMPOUND", SEE SPECIAL PROVISIONS.
12. IF CONCRETE COVER OVER EXISTING REINFORCING AND WELDED WIRE REINFORCEMENT IS LESS
THAN 1" PROVIDE A BUMP-OUT TO ENSURE A MINIMUM COVER OF 2" AND ADJUST THE DEPTH OF
SAW CUT TO AVOID CUTTING INTO BARS.
CULVERT REPAIR CONCRETE NOTES:
REPAIR DETAIL APPLIES TO AREAS OF REINFORCED CONCRETE WHERE THERE IS EXPOSED REINFORCING
AFTER REMOVAL OF LOOSE AND DETERIORATED CONCRETE.
1. REMOVE DETERIORATED MATERIAL TO SOUND CONCRETE LEAVING NO OFFSET OR ABRUPT
CHANGES IN CONTOUR. CONCRETE SHALL BE REMOVED TO 1" BELOW THE EXISTING
REINFORCING. REMOVAL OF SOUND CONCRETE MAY BE REQUIRED.
2. CONTRACTOR SHALL USE FIFTEEN (15) POUND HAMMERS MAXIMUM OR OTHER METHODS
ACCEPTED BY THE ENGINEER.
3. PRIOR TO APPLYING REPAIR CONCRETE MATERIAL, CLEAN EXISTING REINFORCING STEEL AND
CONCRETE (NEWLY EXPOSED) BY SANDBLASTING, SEE SPECIFICATIONS. MISSING OR
DETERIORATED REINFORCING STEEL SHALL BE REPLACED AS SHOWN IN DETAIL AND AS DIRECTED
BY THE ENGINEER.
4. AFTER SANDBLASTING AND CLEANING ALL DUST AND DEBRIS, INSTALL GALVANIC ANODES AND
WELDED WIRE REINFORCEMENT AS REQUIRED. AFTER SANDBLASTING AND BEFORE PLACING
REPAIR CONCRETE, DUST AND DEBRIS SHALL BE REMOVED COMPLETELY.
5. ENSURE THAT CONCRETE SUBSTRATE IS WETTED (SSD) BEFORE PLACING REPAIR CONCRETE.
6. FORM, WHEN APPLICABLE, AND PLACE REPAIR CONCRETE. CONCRETE FOR OVERHEAD REPAIRS
SHALL BE PUMPED INTO THE EXCAVATED SPACE, USING VENT TUBES AS NECESSARY TO ENSURE
THAT NO AIR IS TRAPPED IN THE PATCH.
7. IMMEDIATELY FOLLOWING CURING AND STRIPPING OF FORMS, THE NEWLY PLACED REPAIR
CONCRETE SURFACE WITHIN REPAIR AREAS SHALL BE HAMMER-TAPPED FOR SOUNDNESS. SOUND
PATCH AREAS SHALL RECEIVE A GROUT CLEAN-DOWN FINISH. ADJACENT AREAS SHALL NOT
RECEIVE SUCH A FINISH.
8. AFTER REPAIRS HAVE BEEN ACCEPTED, APPLY PENETRATING SEALER TO THE REPAIRED AREAS AS
WELL AS CONTIGUOUS AREAS TO THE REPAIR OR AS DIRECTED BY THE ENGINEER.
9. MINOR SPALLS AND SCALING LESS THAN 1/2" DEEP WITH NO REINFORCING EXPOSED AND WITH
SOUND CONCRETE REMAINING MAY BE SEALED WITH PENETRATING SEALER WITH NO REPAIR
REQUIRED UNLESS DIRECTED OTHERWISE BY THE ENGINEER.
CULVERT REPAIR CONCRETE PROCEDURE:
*REQUIREMENTS FOR WELDED WIRE REINFORCEMENT:
1.REQUIRED WHEN INSUFFICIENT BARS ARE AVAILABLE TO SECURE THE REPAIR CONCRETE.
A. FOR VERTICAL APPLICATIONS, REPAIR CONCRETE SHALL BE SECURED BY DEFORMED
STEEL BARS AT A 12" SPACING OR LESS, OR BY WELDED WIRE REINFORCEMENT
SECURED ON A 6" GRID BY TIE WIRES AND APPROVED ANCHORS INTO SOUND
CONCRETE.
B. FOR OVERHEAD APPLICATIONS WHERE BAR SPACING EXCEEDS 6", ADD WELDED
WIRE REINFORCEMENT SECURED TO SOUND CONCRETE AND REINFORCING ON A
6" GRID.
2.ACCEPTABLE ALTERNATIVES TO WELDED WIRE REINFORCEMENT TO SUPPLEMENT
REINFORCING INCLUDE NON-METALLIC MESH AND #3 FRP OR GALVANIZED STEEL
BARS.
NOTE: REMOVAL DETAILS SHOWN FOR VERTICAL
SURFACE, SIMILAR FOR OVERHEAD REMOVAL
(SEE REPAIR CONCRETE NOTE 13)
NOT TO SCALE
04.09
K:
Clough, Harbour & Associates, LLP
7/16/2026
SIGNATURE BLOCK: DRAWING TITLE:
S-10
REHABILITATION OF BRIDGE NO. 02150;
PLOTTED DATE:
V:\Projects\ANY\K6\070461.000\16_Custom_Client\CT Connect\Bridge\Contract_Plans\BR_CP_0138_0252_S_09_S_10_Culvert_Repair_Details_2_3.dgn FILE NAME: 7485 LASTED SAVED BY:
R E
V
D A
T E
R E
V
IS
IO
N
D E
S C
R
IP
T
CULVERT REPAIR DETAILS III
TRANSPORTATION
NOTE: IF EXISTING REINFORCING SPACING IS DIFFERENT THAN INDICATED
IN THIS TABLE, CONTACT ENGINEER FOR MAXIMUM ANODE SPACING.
SECTION - CULVERT WALL REPAIR TYPE I
SCALE: 1
2" = 1'-0"
ANCHOR
AND BOND
DRILL HOLE
(LENGH VARIES)
#4 BENT BAR
EXISTING STEEL REINFORCEMENT
BOX CULVERT SIDE WALL
INTERIOR FACE OF EXISTING
JOINT
CONSTRUCTION
EXISTING
M
IN
S P
L
IC
E
12"
L
IM
IT
S
O F
D E
T E
R
IO
R A
T E
D C
O N
C R
E T
E
L
IM
IT
S
O F
R E
P A
IR
C
O N
C R
E T
E
S E
E N
O T
E
OF REPAIR AREA
AROUND PERIMETER
SOUND CONCRETE
1" DEEP SAWCUT IN
(SEE REPAIR NOTE 1)
ANODE (TYP.)
EMBEDDED GALV.
DETAIL - CULVERT WALL REPAIR TYPE IA
SCALE: 1
2" = 1'-0"
#4 BAR (LENGTH VARIES)
EXISTING CONSTRUCTION JOINT
EXTENDS TO THIS SURFACE
SURFACE IF DETERIORATION
CONCRETE ALONG SLOPED
1" DEEP SAWCUT IN SOUND
#4 BAR (LENGTH VARIES)
(SEE REPAIR NOTE 1)
REMOVAL
LIMITS OF CONCRETE
AND HAUNCH)
(BOTTOM SLAB
CULVERT INVERT
ENGINEER
DIRECTED BY THE
CORRODED BAR AS
REMOVE PORTION OF
(SEE REPAIR NOTE 1)
REMOVE DETERIORATED CONCRETE
REQUIRED (SEE REPAIR NOTE 1)
REMOVE SOUND CONCRETE AS
PLAN - NARROW STRIP
DEEP"2
SAW CUT EDGES OF PATCH
IN EMBEDDING MORTAR
TYPE I ANODE INSTALLED
OF SAWCUT LINE (TYP.)
SOUND CONCRETE OUTSIDE
*CONCRETE COVER REQUIREMENTS:
1" MAY BE REDUCED TO
4" IF NEAT
PATCHING MORTAR IS USED
REINFORCING BARS (TYP.)
BLAST CLEAN EXPOSED
EMBEDDING MORTAR
SURFACE REPAIR CONCRETE
2" COVER
AT ANODE
1" *MIN.
DEEP"2
SAW CUT EDGES OF PATCH
TO REINFORCING BAR
TIE ELECTRODE FROM ANODE
SURFACE REPAIR CONCRETE
REINFORCING BARS (TYP.)
BLAST CLEAN EXPOSED
IN EMBEDDING MORTAR
TYPE I ANODE INSTALLED
EMBEDDING MORTAR
TO REINFORCING BAR (TYP.)
TIE ELECTRODE FROM ANODE
DEEP"2
PATCH
SAW CUT EDGES OF
OF SAWCUT LINE (TYP.)
SOUND CONCRETE OUTSIDE
REINFORCING BARS (TYP.)
BLAST CLEAN EXPOSED
SURFACE REPAIR CONCRETE
TYPE I ANODE
DEEP"2
SAW CUT EDGES OF PATCH
STEEL TIE WIRE
SURFACE REPAIR CONCRETE
REINFORCING BARS (TYP.)
BLAST CLEAN EXPOSED
IN EMBEDDING MORTAR
SLIM ANODE INSTALLED
GALVANIZED FUSION T2
EMBEDDING MORTAR
PARTIALLY FILL WITH
IN CONCRETE AND
" DIA. HOLE 8
DRILL 1
COPPER LEAD WIRE
SEALED BUTTON CONNECTOR
TYPE I ANODE
FUSION T2 SLIM ANODE
FUSION T2 SLIM ANODE
SEALED BUTTON CONNECTOR
STEEL TIE WIRE
COPPER LEAD WIRE
EMBEDDING MORTAR
ANODE INSTALLED IN
GALVANIZED FUSION T2 SLIM
EMBEDDING MORTAR
PARTIALLY FILL WITH
CONCRETE AND
" DIA. HOLE IN 8
DRILL 1
PLAN - SMALL PATCH
DEEP"2
PATCH
SAW CUT EDGES OF
LINE (TYP.)
OUTSIDE OF SAWCUT
SOUND CONCRETE
BARS (TYP.)
REINFORCING
EXPOSED
BLAST CLEAN
CONCRETE
SURFACE REPAIR
CONNECTOR
SEALED BUTTON
STEEL TIE WIRE
COPPER LEAD WIRE
IN EMBEDDING MORTAR
SLIM ANODE INSTALLED
GALVANIZED FUSION T2
EMBEDDING MORTAR
PARTIALLY FILL WITH
IN CONCRETE AND
" DIA. HOLE 8
DRILL 1
FUSION T2 SLIM ANODE
NOT TO SCALE
NOT TO SCALE
SECTION - NARROW STRIP
PLAN - LARGE RECTANGULAR PATCH
DEEP"2
SAW CUT EDGES OF PATCH
IN EMBEDDING MORTAR
TYPE I ANODE INSTALLED
OF SAWCUT LINE (TYP.)
SOUND CONCRETE OUTSIDE
REINFORCING BARS (TYP.)
BLAST CLEAN EXPOSED
RESISTIVETY > 15,000 OHM-CM
ANODES WHEN REPAIR CONCRETE
PLACE EMBEDDING MORTAR AT
CONCRETE
SURFACE REPAIR
TO REINFORCING BAR (TYP.)
TIE ELECTRODE FROM ANODE
SECTION - LARGE RECTANGULAR PATCH
2" COVER
AT ANODE
1" *MIN.
DEEP"2
SAW CUT EDGES OF PATCH
TO REINFORCING BAR
TIE ELECTRODE FROM ANODE
SURFACE REPAIR CONCRETE
(TYP.)
BLAST CLEAN EXPOSED REINFORCING BARS
EMBEDDING MORTAR
TYPE I ANODE INSTALLED IN
RESISTIVITY > 15,000 OHM-CM
ANODES WHEN REPAIR CONCRETE
PLACE EMBEDDING MORTAR AT
NOT TO SCALE
NOT TO SCALE
INVERT (HAUNCH)
EXIST. CULVERT
NOT TO SCALE
1" MIN.
12"
REMOVAL BELOW TOP OF HAUNCH
ON DWG. S-09
SPLICE DETAIL
SEE REINFORCEMENT
2"
MAX.
SPLICE BAR)
(1" MIN. BEYOND
SOUND CONCRETE
REMOVE TO
28"28"#4 @24" & #4 @18"WINGWALL
#4@14" & #4@12"BACK FACE
19"25"
#4@14" & #4@12"FRONT FACE
CULVERT HEADWALL
#4 @18" & #7 @4"BOTTOM FACE
13"17"
#4 @18" & #5 @6"TOP FACE
CULVERT TOP SLAB
#4 @18" & #6 @6"OUTSIDE FACE
15"20"
#4 @18" & #5 @12"INSIDE FACE
CULVERT WALL
TYPE 2TYPE 1
MAX. ANODE SPACING
LONGITUDINAL / TRANSVERSE
EXISTING REINFORCING
ELEMENT
MAXIMUM ANODE SPACING TABLE
JRH / JLPSJH
1. SEE "CONCRETE REPAIR DETAILS I" SHEET FOR ADDITIONAL INFORMATION.
2. STEEL REINFORCEMENT FOR SURFACE CONCRETE REPAIR TYPE I AND TYPE IA
TO BE UNCOATED BLACK BAR. SEE DRAWING NO. S-03 "CONCRETE NOTES"
FOR ADDITIONAL INFORMATION.
CONCRETE REPAIR NOTES:
1. ANODES NOTED AS "TYPE 1" ARE TYPICALLY EMBEDDED WITHIN WET
CONCRETE REPAIRS. WHEN THE RESISTIVITY OF THE REPAIR CONCRETE IS
GREATER THAN 15 K-OHM-CM, EMBEDDING MORTAR IS REQUIRED.
"TYPE 2" DESCRIBES ANODES THAT ARE TYPICALLY PLACED IN DRILLED
HOLES IN HARDENED CONCRETE WITH EMBEDDING MORTAR PLACED IN
THE HOLE BEFORE THE ANODE IS PLACED. GALVASHIELD FUSION T2 SLIM
ANODES ARE A PRE-QUALIFIED TYPE 2 ANODE LISTED IN THE SPECIAL
PROVISION. FUSION ANODES ARE DETAILED IN THESE PLANS TO BE
INSTALLED WITH EMBEDDING MORTAR IN…