01 - Pure Architects Addendum 02.pdf
PDF 3 MB Posted
- Solicitation number
- RFP WDS 270000000188 3
- Issued by
- Oakland County, Michigan
About this file
This is an Addendum to the architectural services contract for the WDS Bond Proposal Phase 1 project, involving Ealy Middle School and Shoreline facilities in Michigan. The addendum modifies the original scope of work and contract terms established with Pure Architects for the design and planning services related to the bond-funded school construction project. The document serves to clarify, revise, or expand upon specific requirements, deliverables, or conditions outlined in the initial contract agreement for the Phase 1 design development of these educational facilities.
The addendum addresses modifications to the architectural services scope, which may include adjustments to design phases, fee structures, schedule revisions, or additional services required by the school district. As a supplemental document to the primary contract, this addendum incorporates changes by reference or explicit language and becomes part of the binding agreement between the district and Pure Architects, ensuring both parties operate under updated terms and conditions for the completion of design work on the Ealy Middle School and Shoreline projects within the WDS Bond Proposal Phase 1 initiative.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
-./0- -12/34567895-:8;;523-<=;->/=372?678/=-@<=<A52-
���B%���$� ��������,� ��������C�����D�����,�����+�
-.E83-<;;5=;?F-G/2F3-<-4<27-/G-7E5-6/=372?678/=-;/6?F5=73-<=;-F/;8H53-7E5-/28A8=<I-
-6/=372?678/=-;/6?F5=73J-;<75;-KLMNKMOKOPM-.E5-<;;5=;?F-3E<II-Q56/F5-<-4<27-/G-7E5-
->/=72<67-R/6?F5=73-<=;-3E<II-Q5-7<S5=-8=7/-<66/?=7-8=-4254<28=A-7E5-Q8;M-.E5-T/2SJ-8=-
-5<6E-35678/=J-3E<II-Q5-8=-<66/2;<=65-T87E-7E5-/28A8=<I-U4568H6<78/=3-?=I533-=/75;J-
-34568H6<IIV-8=-7E83-<;;5=;?FM-W6S=/TI5;A8=A-7E5-2565847-/G-7E83-<;;5=;?F-83-25X?825;-
-/=-7E5-:8;-Y/2FM-Y<8I?25-7/-;/-3/-F<V-3?QZ567-:8;;52-7/-;83X?<I8H6<78/=M-
-]M- -̂/=5-
-]M- -̂/=5-
�_��D��
-]M- -̀<IV-
-<M--aKKO0-W;;5;-WI752=<75-I837-7/-6//2;8=<75-T87E-7E5-H=83E-I5A5=;-
-QM--R]K]>0-b5F/95;-=/75-cd-G2/F-25372//F3M-
-6M--WOK]0--@/;8H5;--5378F<75;--658I8=A--25F/9<Ie254I<65F5=7--<25<3--7/--6//2;8=<75--T87E--@ 1̀-
-<Q/95-658I8=A-T/2SM-
-OM--@8;;I5-U6E//I0-
-<M--aKKO0-W;;5;-Wf-7/-7E5-WI752=<753-g5A5=;-7/-6//2;8=<75-T87E-7E5-H=83E-I5A5=;-
-QM--R]K]:0-b5F/95;-<25<-/G-3I<Q-;5F/-
-6M--W]OK0-b//G-;57<8I-25G525=65-25F/95;M-
-;M--WdO]0-
-8M--R57<8I-cO0-Y8h5;-A2<4E863-
-88M--R57<8I--cd--i--cP0--W;;5;--<--=/75--6<II8=A--G/2--425H=83E5;--38II--j<3E8=A--7/--F<76E--;57<8I-
-cO-
-5M--kKK]0->E<=A5;-1.K]lWd-7/-��m (n�!�-7/-6//2;8=<75-T87E-7E5-<I752=<75-I837-/=-aKKO-
-GM- -U]K]:0-o4;<75;-=/753-G/2-A5/G/<F-<=;-6/=62575-7E86S=533M-
-TTTM4?25<26E875673M6/F-
***�+,-��-���.��./�� 0
TYPICAL SYMBOLS & REFERENCESLG
ND
REFERENCE CALLOUT SYMBOL
A101
SIM
DETAIL NUMBER
SHEET NUMBER
EXTERIOR ELEVATION
REFERENCE BUBBLE A101
A ELEVATION LETTER
BUILDING SECTION SYMBOL
A101
SIM
SECTION NUMBER
SHEET NUMBER
INTERIOR ELEVATION
REFERENCE BUBBLE
A101
SHEET NUMBER
A
A
A
A
SIMILAR CONDITION
OPP
OPPOSITE CONDITION
ELEVATION LETTER
SIMILAR CONDITION
OPP
OPPOSITE CONDITION VIEW DIRECTION
1. THE OWNER RESERVES THE RIGHT TO REMOVE OR
MODIFY SCOPE ITEMS PRIOR TO COMMENCEMENT OF
CONTRACTED WORK.
2. OWNER MAY ACCEPT BASE BID OR ALTERNATE AT TIME
OF AWARD.
3. ALL EXISTING CONDITIONS SHALL BE FIELD VERIFIED
PRIOR TO COMMENCEMENT OF WORK.
4. EXISTING ROOF CONDITIONS MAY VARY FROM
INFORMATION SHOWN. ADDITIONAL REPAIRS OR
MODIFICATIONS MAY BE REQUIRED BASED ON FIELD
CONDITIONS AND SHALL BE COORDINATED WITH THE
OWNER PRIOR TO PROCEEDING.
5. COORDINATE ROOF WORK WITH ONGOING BUILDING
OPERATIONS.
6. CONTRACTOR SHALL PROTECT EXISTING BUILDING, ROOF
AREAS, AND INTERIOR SPACES FROM WATER INTRUSION
DURING CONSTRUCTION.
GENERAL ARCHITECTURAL NOTESNO
TE
S
NOTE:
MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED
OTHERWISE. SWITCHES (LOCATE ON LATCH SIDE, IF
SWITCH OR DEVICE CANNOT BE
LOCATED ON LATCH SIDE, LOCATE
ONE DOOR LEAF WIDTH AWAY ON
HINGE SIDE) STACK UP TO 2 HIGH
DEVICES TO KEEP WITHIN ADA REACH.
DOOR
LOW
DEVICES
RECEPTACLEVOICE/DATA
MASONRY COURSING
(WHERE APPLICABLE)
F.A. PULL STATION
THERMOSTAT
F.A. AUDIO/VISUAL
ALIGNMENT NOTES
• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.
• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.
• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.
• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT
• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.
F
R O
M F
L O
O R
O R
L A
N D
IN
G
F R
O M
F L
O O
R O
R L
A N
D
IN
G
CARD READER
6' - 0" MIN.
4" MAX
CAMERAS, CLOCKS,
WALL OCCUPANCY
SENSORS
WHITE BOARD (WHERE
APPLICABLE - VERIFY WITH
DETAILS/PLANS PROPER
INSTALL HEIGHT) CENTER ANY
SINGLE DEVICE WITH CENTER
OF WHITE BOARD
ANY DEVICES
SHOWN OVER
DOOR TO BE
CENTERED.
EQ EQ
EQ EQ
F
R O
M F
L O
O R
O R
L A
N D
IN
G
SHORT THROW
PROJECTOR WHERE
APPLICABLE
~12"
MAX TWO DEVICES IN
ONE HIGHER MOUNT
LOCATION, PROVIDE RFI
IF MORE DEVICES ARE
NECESSARY
WHEN DEVICES ARE WITHIN DIMENSION,
STACK HIGH/LOW VERTICALLY AND GROUP
DEVICES AT SAME HEIGHT. UNLESS
DEVICES IS PART OF TECHNOLOGY DETAIL
GROUPING OR SERVING A FURNITURE
GROUP.
CASEWORK, COORDINATE DEVICE
BOTTOM TO BE 2" OVER
BACKSPLASH OR OVER
COUNTERTOP (IF NO BACKSPLASH).
FOR LARGE FORMAT TILE, ALIGN
EDGE OF DEVICE WITH HORIZONTAL
GROUT LINE CLOSEST TO
COUNTERTOP.
COORDINATE OUTLET LOCATIONS
WITH GROUT LINES, EDGE OF
DEVICE ON GROUT LINE IF POSSIBLE.
COORDINATE WITH INTERIOR
DESIGN DRAWINGS.
S
TYPICAL COLUMN
ENCLOSURE, CHASE
OR BUMP-OUT WITH
DEVICES INDICATED
IN PLANS.
EQ EQ
M A
X
4" MAX.
M
IN
PROTRUDING
OBJECTS
REDUCED VERTICAL
CLEARANCE
WATER CLOSET &
LAVATORY CLEARANCE
403.5
CLEAR WIDTH
ACCESSIBLE ROUTE
TRANSFER SHOWER
CLEARANCE
404.2.3.2(A)
FRONT APPROACH PULL SIDE
*IF BOTH CLOSER AND LATCH
ARE PROVIDED
404.2.3.2(B)
FRONT APPROACH PUSH SIDE
*IF BOTH CLOSER AND LATCH
ARE PROVIDED - NEW
BUILDINGS
404.2.3.2(E)
HINGE APPROACH PULL SIDE
404.2.3.2(F)
HINGE APPROACH PUSH SIDE
*48" MIN IF BOTH CLOSER AND
LATCH ARE PROVIDED
404.2.3.2(G)
LATCH APPROACH PULL SIDE
*54" IF CLOSER IS PROVIDED
404.2.3.2(H)
LATCH APPROACH PUSH SIDE
*48" IF CLOSER IS PROVIDED
CHANGES IN LEVEL
NOTE:
INFORMATION SHOWN IS TAKEN FROM THE AMERICAN
NATIONAL STANDARD INSTITUTE (ANSI) AND IS FOR
REFERENCE ONLY AS DESCRIBED IN: ANSI ICC A117.1-2017
M A
X
M
IN
" C L
E A
R
M
IN
CLEAR
60" MIN.
M
IN
MIN.
30"
MIN.
36"
MIN.
32"
M A
X
M
IN
M A
X
S E
A T
W
L
L
BACK
WALL
36"
48"
M
IN
MIN.
18" *
M
IN
MIN.
12" *
M
IN
42" MIN.
M
IN
MIN.
22"
M
IN
MIN.
24"
M
IN
MIN.
24"
1/
M A
X
1/
M A
X
1/
M A
X
1/
M A
X
ACCESSIBLE BUILDING CLEARANCESLG
ND
MIN.
15"
MIN.
16"
M
A X
M
IN
8" MIN
6" MIN 11"
MAX
25"
M
IN
KNEE
CLEARANCE
ø
304.3.1.1
NEW BUILDING
TURNING RADIUS
ø
304.3.1.2
EXISTING BUILDING
TURNING RADIUS
ø
OVERLAP AREA
304.3.2
T-SHAPED TURNING RADIUS
NEW BUILDINGS - OPTION 1
68" MIN.
M
IN
16" MIN. 36" MIN. 16" MIN.
M
IN
M
IN
304.3.2
T-SHAPED TURNING RADIUS
NEW BUILDINGS - OPTION 2
64" MIN.
M
IN
11" MIN. 42" MIN. 11" MIN.
M
IN
M
IN
304.3.2
T-SHAPED TURNING RADIUS
NEW BUILDINGS - OPTION 3
64" MIN.
M
IN
12" MIN. 40" MIN. 12" MIN.
M
IN
M
IN
304.3.2.2
T-SHAPED TURNING RADIUS
EXISTING BUILDINGS
60" MIN.
M
IN
12" MIN. 36" MIN. 12" MIN.
M
IN
M
IN
305.3.1
NEW BUILDING
CLEAR FLOOR SPACE
52" MIN.
M
IN
305.3.2
EXISTING BUILDING
CLEAR FLOOR SPACE
48" MIN.
M
IN
404.2.3.2(C)
FRONT APPROACH PUSH SIDE
*IF BOTH CLOSER AND LATCH
ARE PROVIDED - EXISTING
BUILDINGS
M
IN
MIN.
12" *
404.2.3.2(D)
HINGE APPROACH PULL SIDE
M
IN
36" MIN.
ALTERNATE LISTLG
ND
A3: REMOVE AND REPLACE EXISTING WINDOW
COVERINGS
- BASE BID - EXISTING TO REMAIN
- REFER TO INTERIOR FINISH PLANS FOR LOCATIONS
- REFER TO MATERIAL SELECTION SCHEDULE FOR DETAIL
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
E al y E le m en ta ry W h it eh al l D is tr ic t S ch o o ls
E
S o p h ia S t, W h it e h a ll
, M I
PROJECT NO. 25.147
G002
DRAWING INDEX,
GENERAL NOTES, AND
ACCESSIBILITY
10.08.26
SHEET LIST
SHEET # SHEET NAME
GENERAL
G001 COVER SHEET
G002 DRAWING INDEX, GENERAL NOTES, AND ACCESSIBILITY
G101 FIRST FLOOR CODE COMPLIANCE PLANS
DEMOLITION
D101 FIRST FLOOR DEMOLITION PLAN
D101A FIRST FLOOR DEMOLITION PLAN - UNIT A
D101B FIRST FLOOR DEMOLITION PLAN - UNIT B
D101C FIRST FLOOR DEMOLITION PLAN - UNIT C
D101D FIRST FLOOR DEMOLITION PLAN - UNIT D
D102 ROOF DEMOLITION PLAN
D201 FIRST FLOOR CEILING DEMOLITION PLAN
ARCHITECTURAL
A101 FIRST FLOOR PLAN
A101A FIRST FLOOR PLAN - UNIT A
A101B FIRST FLOOR PLAN - UNIT B
A101C FIRST FLOOR PLAN - UNIT C
A101D FIRST FLOOR PLAN - UNIT D
A102 ROOF PLAN
A201 FIRST FLOOR REFLECTED CEILING PLAN
INTERIORS
I101 FIRST FLOOR FINISH PLAN
MECHANICAL DEMOLITION
MD101A MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT A
MD101B MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT B
MD101C MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT C
MD101D MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT D
MD102A MECHANICAL DEMOLITION ROOF PLAN - UNIT A
MD102C MECHANICAL DEMOLITION ROOF PLAN - UNIT C
MECHANICAL
M101A MECHANICAL HVAC FIRST FLOOR PLAN - UNIT A
M101B MECHANICAL HVAC FIRST FLOOR PLAN - UNIT B
M101C MECHANICAL HVAC FIRST FLOOR PLAN - UNIT C
M101D MECHANICAL HVAC FIRST FLOOR PLAN - UNIT D
M102A MECHANICAL HVAC ROOF PLAN - UNIT A
M102B MECHANICAL HVAC ROOF PLAN - UNIT B
M102C MECHANICAL HVAC ROOF PLAN - UNIT C
M102D MECHANICAL HVAC ROOF PLAN - UNIT D
M200 MECHANICAL SCHEDULES
M201 MECHANICAL DETAILS
M202 MECHANICAL NOTES & ABBREVIATIONS
M300 MECHANICAL CONTROLS
M301 MECHANICAL CONTROLS
M302 MECHANICAL CONTROLS
ELECTRICAL DEMOLITION
ED101A ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT A
ED101B ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT B
ED101C ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT C
ED101D ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT D
ED102C ELECTRICAL DEMOLITION ROOF PLAN - UNIT C
ELECTRICAL
E101 ELECTRICAL POWER FIRST FLOOR PLAN - OVERALL
E101A ELECTRICAL POWER FIRST FLOOR PLAN - UNIT A
E101B ELECTRICAL POWER FIRST FLOOR PLAN - UNIT B
E101C ELECTRICAL POWER FIRST FLOOR PLAN - UNIT C
E101D ELECTRICAL POWER FIRST FLOOR PLAN - UNIT D
E102A ELECTRICAL POWER ROOF PLAN - UNIT A
E102C ELECTRICAL POWER ROOF PLAN - UNIT C
E102D ELECTRICAL POWER ROOF PLAN - UNIT D
E201A ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT A
E300 ELECTRICAL NOTES & SYMBOLS
E301 ELECTRICAL ONE-LINE DIAGRAM
E302 ELECTRICAL DETAILS & SCHEDULES
E303 ELECTRICAL PANEL SCHEDULES
TECHNOLOGY
T101 TECHNOLOGY SYMBOL LEGEND
T102A TECHNOLOGY PLAN - UNIT A
T102B TECHNOLOGY PLAN - UNIT B
NOT TO SCALE
DEVICE ALIGNMENT GUIDELINES
SYM DATE ISSUED FOR
A2 11.06.26 BID ADD #02
A2
1. CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE
EXISTING BUILDING PRIOR TO RELATED DEMOLITION
WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY
WALL, FLOOR OR CEILING INCLUDES ALL GENERAL
MECHANICAL AND ELECTRICAL ITEMS WHICH ARE A PART
OF, OR ATTACHED TO IT.
2. CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE
CONDITIONS AND DIMENSIONS AND BE RESPONSIBLE
FOR THE SAME. ADVISE ARCHITECT OF ANY AND ALL
DISCREPANCIES.
3. PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING
CONSTRUCTION AND DEMOLITION AS REQUIRED. FINISH
TO MATCH EXISTING.
4. ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.
5. PROTECT ALL EXISTING FINISHES THROUGHOUT PROJECT.
6. REFER TO DEMOLITION ELEVATIONS, SECTIONS AND
DETAILS FOR ADDITIONAL INFORMATION.
7. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND
ELECTRICAL PLANS FOR ADDITIONAL DEMOLITION NOTES.
8. SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN
NEW CONSTRUCTION, IF REQUIRED.
9. AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED
ITEMS ATTACHED TO THE WALL ARE TO BE REMOVED.
SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,
TACKBOARDS, TACK STRIPS, ETC.
GENERAL DEMOLITION NOTESNO
TE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
BOYS RR
GIRLS RR
CLASSROOM
CLASSROOM
COMMONS
CLASSROOM
CLASSROOM
CORRIDOR
1 2
1 2
1 2
1 2
1 2
UNIT A
UNIT C
U N
IT
B
U N
IT
C
U N
IT
C
U N
IT
D
U N
IT
C
U N
IT
D
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
E al y E le m en ta ry W h it eh al l D is tr ic t S ch o o ls
E
S o p h ia S t, W h it e h a ll
, M I
PROJECT NO. 25.147
D101C
FIRST FLOOR
DEMOLITION PLAN -
UNIT C
10.08.26
DEMOLITION KEYED NOTES
1 REMOVE EXISTING MECHANICAL EQUIPMENT.
CORDINATE WITH MECHANICAL DRAWINGS. PREP FOR
NEW WORK.
2 REMOVE EXISTING WALL LOUVER. COORDINATE WITH
MECHANICAL. PREP FOR NEW WORK
3 REMOVE EXISTING CABINET HEATER CORDINATE WITH
MECHANICAL. PREP FOR NEW WORK.
4 SALVAGE EXISTING CARPET TILE AROUND MECHANICAL
EQUIPMENT FOR PATCH AND REPAIR
5 REMOVE EXISTING COUNTERTOPS AND PANEL
MOLDING. SALVAGE MOLDING FOR REUSE. CASEWORK
TO REMAIN. PREP FOR NEW SOLID SURFACE
COUNTERTOP MATERIAL.
6 REMOVE EXISTING FLOOR AND WALL BASE.
NO
TE
NR
TH 1/8" = 1'-0"
UNIT C DEMOLITION PLAN
SYM DATE ISSUED FOR
A2 11.06.26 BID ADD #02
UNIT A
UNIT D
U N
IT
A
U N
IT
D
UNIT A
UNIT C
U N
IT
B
U N
IT
C
U N
IT
C
U N
IT
D
U N
IT
C
U N
IT
D
U N
IT
B
U N
IT
A
FLEX
INSTRUCTIONAL
CLASSROOM
FLEX
INSTRUCTIONAL
CLASSROOM
FLEX
INSTRUCTIONAL
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR CORRIDOR COMMONS
CLASSROOM
CLASSROOM
GIRLS RR
BOYS RR
CLASSROOM
CLASSROOM
CLASSROOM
BREAK OUT
CLASSROOM
BREAK OUTRR
CLASSROOMCLASSROOM
CLASSROOMCLASSROOM
CLASSROOM
UPPER MECH
GYM COMMONS
GYM
PERFORMING
ARTS
OFFICE
GIRLS RR
BOYS RR
COPYOFFICE
JCJC
CLASSROOMCLASSROOM
KITCHEN
SERVING
CAFETERIA
ART ROOM
ART ROOMSTAFF LOUNGE
RECEPTION/WAITING
CONF. ROOMMAIL OFFICE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
STORAGE
OFFICE
CLASSROOM CLASSROOM
BOYS RR
GIRLS RR
OFFICE
MEDIA CENTERLARGE GROUP
INSTRUCTION
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
NOT IN
SCOPE
GYPSUM BOARD
ACP01: 24' x 24' LAY-IN ACOUSTICAL
TILE GRID
1. REFER TO MATERIAL SELECTION SCHEDULE FOR CEILING
SELECTIONS.
2. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF
ROOM PROVIDE A CUT 2x4 TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH 2x2
FOR STYLE AND COLOR.
3. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE,
DUCTWORK, PIPING, CONDUIT, HANGERS ETC.,
COORDINATE WITH MECHANICAL, ELECTRICAL AND
PLUMBING SPECIFICATIONS. REFER TO THE REFLECTED
CEILING PLANS FOR PAINT COLORS.
REFLECTED CEILING LEGEND
GENERAL NOTES - REFLECTED CEILINGS
ACP02: 24' x 48' LAY-IN ACOUSTICAL
TILE GRID
1t Y X 1'-0"
CEILING HEIGHT ABOVE
FINISHED FLOOR
CEILING FINISH TYPE
CEILING FINISH INSTANCE
LG
ND
NO
TE
INFILL WITH NEW CEILING TILES AND GRID TO
MATCH EXISTING ADJACENT TILES
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
E al y E le m en ta ry W h it eh al l D is tr ic t S ch o o ls
E
S o p h ia S t, W h it e h a ll
, M I
PROJECT NO. 25.147
A201
FIRST FLOOR
REFLECTED CEILING
PLAN
10.08.26
NR
TH 1/16" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
BULKHEAD TO BE
PAINTED, P03. IN MEDIA
CENTER PAINT BAND TO
CONTINUE AROUND
WALL PERIMETER AT
CEILING REPLACING
"HUNTER GREEN"
SYM DATE ISSUED FOR
A2 11.06.26 BID ADD #02
A2
A2
TYPICAL SYMBOLS & REFERENCESLG
ND
REFERENCE CALLOUT SYMBOL
A101
SIM
DETAIL NUMBER
SHEET NUMBER
EXTERIOR ELEVATION
REFERENCE BUBBLE A101
A ELEVATION LETTER
BUILDING SECTION SYMBOL
A101
SIM
SECTION NUMBER
SHEET NUMBER
INTERIOR ELEVATION
REFERENCE BUBBLE
A101
SHEET NUMBER
A
A
A
A
SIMILAR CONDITION
OPP
OPPOSITE CONDITION
ELEVATION LETTER
SIMILAR CONDITION
OPP
OPPOSITE CONDITION VIEW DIRECTION
1. THE OWNER RESERVES THE RIGHT TO REMOVE ANY ITEM
FROM THE PROJECT PRIOR TO COMMENCEMENT OF
CONTRACTED DEMOLITION WORK.
2. ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED
BEFORE WORK BEGINS.
3. DIMENSIONS GIVEN ARE ACTUAL AND ARE TO THE FACE
OF MASONRY UNITS OR TO THE FACE OF STUD FRAMING
FOR NEW WORK, UNLESS NOTED OTHERWISE. WHERE
APPLICABLE, DIMENSIONS FROM EXISTING CONDITIONS
IS TO THE FACE OF FINISH.
4. DETAILS SHOWN ILLUSTRATE DESIGN INTENT, NOT ALL
POSSIBLE CONDITIONS. FOR CONDITIONS NOT SHOWN,
USE DETAILS CLOSEST TO CONDITION IN QUESTION.
5. DOORS ARE TO BE 4" FROM CORNER OF ROOM, UNLESS
NOTED OR DIMENSIONED OTHERWISE.
6. FIRESTOP ALL INTERCONNECTIONS BETWEEN VERTICAL
AND HORIZONTAL SPACES AND CONCEALED WALL
SPACES AT CEILING, FLOOR AND ROOF LEVELS.
7. FIRESEAL ALL PENETRATIONS, SUCH AS, PIPES, DUCTS,
CONDUITS, ETC. THROUGH FIRE AND/OR SMOKE RATED
ASSEMBLIES.
8. FOR CONTROL JOINT (C.J.) LOCATIONS REFER TO
EXTERIOR ELEVATIONS AND/OR FLOOR PLANS.
9. PAINT ALL ELECTRICAL PANEL COVERS AND ACCESS
PANELS TO MATCH ADJACENT FINISHES. USING OIL-
BASED PAINT, NOT LATEX WALL PAINT.
10. PROVIDE WOOD BLOCKING IN WALLS THAT REQUIRE
WALL MOUNTED EQUIPMENT OR ACCESSORIES.
COORDINATE WITH EQUIPMENT OR ACCESSORY
MANUFACTURER.
11. PROVIDE ALL ASSOCIATED CURBS FOR ROOF TOP
EQUIPMENT AND MECHANICAL ROOF TOP UNITS. LARGE
VOIDS BELOW THE AIR HANDLING UNITS SHALL BE
FILLED WITH INSULATION AS SPECIFIED FOR NOISE
CONTROL.
12. ALL EXISTING ROOF TOP PENETRATIONS BEING
REMOVED REQUIRE ROOF PATCHING TO MATCH
EXISTING ADJACENT.
13. ALL TOILET ROOM ACCESSORIES INCLUDING ALL
REQUIRED GRAB BARS, SOAP DISPENSERS, MIRRORS,
PAPER TOWEL DISPENSERS, SANITARY NAPKIN
DISPOSALS, TOILET PAPER DISPENSERS, AND BABY
CHANGING TABLES ARE TO BE CONTRACTOR FURNISHED
AND CONTRACTOR INSTALLED UNLESS NOTED
OTHERWISE.
GENERAL ARCHITECTURAL NOTESNO
TE
S
NOTE:
MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED
OTHERWISE. SWITCHES (LOCATE ON LATCH SIDE, IF
SWITCH OR DEVICE CANNOT BE
LOCATED ON LATCH SIDE, LOCATE
ONE DOOR LEAF WIDTH AWAY ON
HINGE SIDE) STACK UP TO 2 HIGH
DEVICES TO KEEP WITHIN ADA REACH.
DOOR
LOW
DEVICES
RECEPTACLEVOICE/DATA
MASONRY COURSING
(WHERE APPLICABLE)
F.A. PULL STATION
THERMOSTAT
F.A. AUDIO/VISUAL
ALIGNMENT NOTES
• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.
• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.
• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.
• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT
• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.
F
R O
M F
L O
O R
O R
L A
N D
IN
G
F R
O M
F L
O O
R O
R L
A N
D
IN
G
CARD READER
6' - 0" MIN.
4" MAX
CAMERAS, CLOCKS,
WALL OCCUPANCY
SENSORS
WHITE BOARD (WHERE
APPLICABLE - VERIFY WITH
DETAILS/PLANS PROPER
INSTALL HEIGHT) CENTER ANY
SINGLE DEVICE WITH CENTER
OF WHITE BOARD
ANY DEVICES
SHOWN OVER
DOOR TO BE
CENTERED.
EQ EQ
EQ EQ
F
R O
M F
L O
O R
O R
L A
N D
IN
G
SHORT THROW
PROJECTOR WHERE
APPLICABLE
~12"
MAX TWO DEVICES IN
ONE HIGHER MOUNT
LOCATION, PROVIDE RFI
IF MORE DEVICES ARE
NECESSARY
WHEN DEVICES ARE WITHIN DIMENSION,
STACK HIGH/LOW VERTICALLY AND GROUP
DEVICES AT SAME HEIGHT. UNLESS
DEVICES IS PART OF TECHNOLOGY DETAIL
GROUPING OR SERVING A FURNITURE
GROUP.
CASEWORK, COORDINATE DEVICE
BOTTOM TO BE 2" OVER
BACKSPLASH OR OVER
COUNTERTOP (IF NO BACKSPLASH).
FOR LARGE FORMAT TILE, ALIGN
EDGE OF DEVICE WITH HORIZONTAL
GROUT LINE CLOSEST TO
COUNTERTOP.
COORDINATE OUTLET LOCATIONS
WITH GROUT LINES, EDGE OF
DEVICE ON GROUT LINE IF POSSIBLE.
COORDINATE WITH INTERIOR
DESIGN DRAWINGS.
S
TYPICAL COLUMN
ENCLOSURE, CHASE
OR BUMP-OUT WITH
DEVICES INDICATED
IN PLANS.
EQ EQ
M A
X
4" MAX.
M
IN
PROTRUDING
OBJECTS
REDUCED VERTICAL
CLEARANCE
WATER CLOSET &
LAVATORY CLEARANCE
403.5
CLEAR WIDTH
ACCESSIBLE ROUTE
TRANSFER SHOWER
CLEARANCE
404.2.3.2(A)
FRONT APPROACH PULL SIDE
*IF BOTH CLOSER AND LATCH
ARE PROVIDED
404.2.3.2(B)
FRONT APPROACH PUSH SIDE
*IF BOTH CLOSER AND LATCH
ARE PROVIDED - NEW
BUILDINGS
404.2.3.2(E)
HINGE APPROACH PULL SIDE
404.2.3.2(F)
HINGE APPROACH PUSH SIDE
*48" MIN IF BOTH CLOSER AND
LATCH ARE PROVIDED
404.2.3.2(G)
LATCH APPROACH PULL SIDE
*54" IF CLOSER IS PROVIDED
404.2.3.2(H)
LATCH APPROACH PUSH SIDE
*48" IF CLOSER IS PROVIDED
CHANGES IN LEVEL
NOTE:
INFORMATION SHOWN IS TAKEN FROM THE AMERICAN
NATIONAL STANDARD INSTITUTE (ANSI) AND IS FOR
REFERENCE ONLY AS DESCRIBED IN: ANSI ICC A117.1-2017
M A
X
M
IN
" C L
E A
R
M
IN
CLEAR
60" MIN.
M
IN
MIN.
30"
MIN.
36"
MIN.
32"
M A
X
M
IN
M A
X
S E
T
W
L
L
BACK
WALL
36"
48"
M
IN
MIN.
18" *
M
IN
MIN.
12" *
M
IN
42" MIN.
M
IN
MIN.
22"
M
IN
MIN.
24"
M
IN
MIN.
24"
1/
M A
X
1/
M A
X
1/
M A
X
1/
M A
X
ACCESSIBLE BUILDING CLEARANCESLG
ND
MIN.
15"
MIN.
16"
M
A X
M
IN
8" MIN
6" MIN 11"
MAX
25"
M
IN
KNEE
CLEARANCE
ø
304.3.1.1
NEW BUILDING
TURNING RADIUS
ø
304.3.1.2
EXISTING BUILDING
TURNING RADIUS
ø
OVERLAP AREA
304.3.2
T-SHAPED TURNING RADIUS
NEW BUILDINGS - OPTION 1
68" MIN.
M
IN
16" MIN. 36" MIN. 16" MIN.
M
IN
M
IN
304.3.2
T-SHAPED TURNING RADIUS
NEW BUILDINGS - OPTION 2
64" MIN.
M
IN
11" MIN. 42" MIN. 11" MIN.
M
IN
M
IN
304.3.2
T-SHAPED TURNING RADIUS
NEW BUILDINGS - OPTION 3
64" MIN.
M
IN
12" MIN. 40" MIN. 12" MIN.
M
IN
M
IN
304.3.2.2
T-SHAPED TURNING RADIUS
EXISTING BUILDINGS
60" MIN.
M
IN
12" MIN. 36" MIN. 12" MIN.
M
IN
M
IN
305.3.1
NEW BUILDING
CLEAR FLOOR SPACE
52" MIN.
M
IN
305.3.2
EXISTING BUILDING
CLEAR FLOOR SPACE
48" MIN.
M
IN
404.2.3.2(C)
FRONT APPROACH PUSH SIDE
*IF BOTH CLOSER AND LATCH
ARE PROVIDED - EXISTING
BUILDINGS
M
IN
MIN.
12" *
404.2.3.2(D)
HINGE APPROACH PULL SIDE
M
IN
36" MIN.
LG
ND
ALTERNATES LIST
A1: REFINISH EXISTING DOOR AND FRAMES TO REMAIN
- REFER TO FLOOR PLAN - PLAN NOTE #8
- REFINISH DOOR AND FRAME TO MATCH NEW
A2: REMOVE AND PROVIDE NEW ALUMINUM DOOR,
FRAME, AND HARDWARE - DOOR NUMBER B100-ALT
- REFER TO FLOOR PLAN - PLAN NOTE #9
- DOOR AND FRAME TO MATCH EXISTING BUILDING
STANDARD RED.
- HARDWARE TO MATCH EXISTING BUILDING STANDARD
FOR ENTRY DOORS.
A3: REMOVE AND REPLACE EXISTING WINDOW
COVERINGS
- BASE BID - EXISTING TO REMAIN
- REFER TO INTERIOR FINISH PLANS FOR LOCATIONS
- REFER TO MATERIAL SELECTION SCHEDULE FOR DETAIL
A4: TUNNEL INFILL IN LIEU OF CRACK REPAIR
- BASE BID - CRACK REPAIR AT THE TUNNEL
- ALTERNATE - DEMO EXISTING TUNNEL LID AND
STRUCTURE AND PROVIDE ENGINEER FILL AND NEW SLAB
ON GRADE.
A5: MOSAIC TILE (PT01-A5)
- REFER TO FINISH LEGEND FOR BASE BID AND ALTERNATE
FOR PT01
A2
1. NOT ALL WALL TYPES MAY BE USED ON PROJECT.
2. REFER TO CODE COMPLIANCE PLANS FOR LOCATIONS OF SMOKE AND
FIRE-RATED PARTITIONS.
3. ALL PARTITIONS EXTEND TO BOTTOM OF STRUCTURE / DECK, UNLESS
NOTED OTHERWISE.
4. LINE OF STRUCTURE/DECK AS SHOWN AT THE HEAD CONDITION OF
EACH PARTITION TYPE IS DIAGRAMMATIC ONLY AND DOES NOT
INDICATE EXACT CONSTRUCTION CONDITIONS. TERMINATE RATED
PARTITIONS AT UNDERSIDE OF STRUCTURAL DECK TO MAINTAIN RATING.
PROVIDE APPROPRIATE FRAMING AND GYPSUM BOARD TO OFFSET
AROUND STRUCTURE OR OTHER OBSTRUCTIONS, SUCH AS PIPING OR
DUCTWORK.
5. PARTITIONS MAY TERMINATE AT STRUCTURAL MEMBERS WITH A RATING
GREATER THAN OR EQUAL THE PARTITION, PROVIDED THAT RATING IS
CONTINUOUS TO STRUCTURAL DECK ABOVE.
6. NON-RATED PARTITIONS THAT EXTEND TO STRUCTURE SHALL
TERMINATE AT UNDERSIDE OF STRUCTURAL DECK TO MAINTAIN A
CONTINUOUS PLANE OF GYPSUM BOARD AS A NOISE, SMOKE OR OTHER
TYPE OF BARRIER.
7. ALL PARTITIONS EXTENDING TO STRUCTURE ABOVE SHALL TERMINATE
WITH DEFLECTION TRACK - SEE TYPICAL DETAILS ON THIS SHEET.
8. ALL GYPSUM BOARD PARTITIONS NOT EXTENDING TO THE STRUCTURE
MUST BE BRACED.
9. UL DESIGN NUMBERS REFER TO THE FIRE RESISTANCE DIRECTORY;
UNDERWRITERS LABORATORY, LATEST EDITION.
10. MISCELLANEOUS NON-RATED CHASES TO BE 5/8" GYPSUM BOARD ON 3
5/8" METAL STUD FRAMING AT 16" O.C., UNLESS NOTED OTHERWISE.
11. MISCELLANEOUS FURRING AROUND COLUMNS TO BE 5/8" GYPSUM
BOARD ON 11/2" STUDS, UNLESS NOTED OTHERWISE.
12. FIRE-RATED PARTITIONS TO HAVE FIRE-STOPPING SEALANTS AT HEAD,
SILL JUNCTURE WITH DISSIMILAR MATERIALS, ETC. AND AROUND ALL
PENETRATIONS AND OPENINGS.
13. WITHIN BUILDING INTERIOR PROVIDE BULLNOSE BLOCK IN CMU WALL
ASSEMBLIES AT ALL EXPOSED OUTSIDE CORNERS, INCLUDING WINDOW
AND DOOR JAMBS, UNLESS NOTED OR DETAILED OTHERWISE. PROVIDE
SQUARE OUTSIDE CORNERS AT ALL LOCATIONS FINISHED WITH WALL
TILE, REFER TO FINISH PLANS (I-SHEETS) FOR LOCATIONS.
14. TOOTH-IN MASONRY AT NEW OPENINGS IN EXISTING WALLS.
15. TOOTH-IN NEW MASONRY INFILL INTO EXISTING OPENINGS AT ALL
BULLNOSE BLOCK LOCATIONS.
16. STUD WALLS SPANNING OVER 12'-0" IN HEIGHT SHALL BE A MINIMUM OF
33 MILS THICKNESS.
17. STUD WALL SUPPORTING WALL CABINETS SHALL BE A MINIMUM OF 33
MILS THICKNESS.
GENERAL PARTITION NOTESNO
TE
UNDERSIDE OF
METAL DECK
3" HIGH LEG METAL
TRACK FASTENED
TO SLAB
MINERAL WOOL
INSULATION CUT
TO DECK PROFILE
(AT METAL DECK
LOCATIONS)
5/8" GYPSUM
BOARD (TYPICAL
EACH SIDE)
METAL RUNNER
CHANNEL, SECURE
TO FLOOR
METAL STUDS AT
SPACING INDICATED
CONTINUOUS
ACOUSTIC SEALANT
(EACH SIDE)
CEILING, REFER
TO PLANS
DO NOT SECURE STUDS
AND GYPSUM BOARD TO
HIGH LEG TRACK
SOUND ATTENUATING
INSULATION WHERE
INDICATED
OCCUPIED SPACE
SIDE
UNOCCUPIED SPACE
SIDE
M
IN
UNDERSIDE OF
METAL DECK
3" HIGH LEG METAL
TRACK FASTENED
TO SLAB
MINERAL WOOL
INSULATION CUT
TO DECK PROFILE
(AT METAL DECK
LOCATIONS)
THICK.
WALL
5/8" GYPSUM
BOARD (TYPICAL
EACH SIDE)
METAL RUNNER
CHANNEL, SECURE
TO FLOOR
METAL STUDS AT
SPACING INDICATED
CONTINUOUS
ACOUSTIC SEALANT
(EACH SIDE)
CEILING, REFER
TO PLANS
1"
DO NOT SECURE STUDS
AND GYPSUM BOARD TO
HIGH LEG TRACK
SOUND ATTENUATING
INSULATION WHERE
INDICATED
UNDERSIDE OF
METAL DECK
3" HIGH LEG METAL
TRACK FASTENED
TO SLAB
MINERAL WOOL
INSULATION CUT
TO DECK PROFILE
(AT METAL DECK
LOCATIONS)
THICK.
WALL
5/8" GYPSUM
BOARD
METAL RUNNER
CHANNEL, SECURE
TO FLOOR
METAL STUDS AT
SPACING INDICATED
CONTINUOUS
ACOUSTIC SEALANT
(EACH SIDE)
CEILING, REFER
TO PLANS
1"
DO NOT SECURE STUDS
AND GYPSUM BOARD TO
HIGH LEG TRACK
SOUND ATTENUATING
INSULATION WHERE
INDICATED
ACOUSTICALLY
IMPROVED GYPSUM
BOARD
STC 45 AND 1 HOUR RATED
WHERE INDICATED PER UL V438
• 1/2" MAXIMUM GAP FOR CONTROL JOINT
• 30'-0" MAX. BETWEEN CONTROL JOINTS
• REFER TO PARTITION TYPES FOR COMPLETE
DESCRIPTION OF COMPONENT PARTS
• ALIGN WITH EDGE OF DOOR FRAME AT HEAD
(AS APPLICABLE)
GYPSUM BOARD
METAL STUD
FRAMING
ACOUSTIC
INSULATION
CONTROL JOINT
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
W h it eh al l M id d le S ch o o l
W h it eh al l D is tr ic t
S ch o o ls
S E li z a b e th S t, W h it e h a ll
, M I
PROJECT NO. 25 146
G002
DRAWING INDEX,
PARTITIONS, NOTES,
AND ACCESSIBILITY
10.08.26
SHEET LIST
SHEET # SHEET NAME
GENERAL
G001 COVER SHEET
G002 DRAWING INDEX, PARTITIONS, NOTES, AND ACCESSIBILITY
G101 FIRST FLOOR CODE COMPLIANCE PLANS
SITE
L000 EXISTING SITE CONDITIONS OVERALL
L001 EXISTING SITE CONDITIONS SOUTH COURTYARD OVERALL
L002 EXISTING CONDITIONS NORTHWEST COURTYARD ENLARGEMENT
L003 DEMOLITION PLAN NORTHWEST COURTYARD ENLARGEMENT
L004 SITE PLAN NORTHWEST COURTYARD ENLARGEMENT
L005 PAVEMENT SCORING PLAN NORTHWEST COURTYARD ENLARGEMENT
L006 GRADING AND DRAINAGE PLAN NORTHWEST COURTYARD ENLARGEMENT
L007 LANDSCAPE PLAN NORTHWEST COURTYARD ENLARGEMENT
L008 EXISTING CONDITIONS SOUTHEAST COURTYARD ENLARGEMENT
L009 DEMOLITION PLAN SOUTHEAST COURTYARD ENLARGEMENT
L010 SITE PLAN AND GRADING PLAN SOUTHEAST COURTYARD ENLARGEMENT
L011 LANDSCAPE PLAN SOUTHEAST COURTYARD ENLARGEMENT
L012 EXISTING CONDITIONS NORTH LAWN OVERALL
L013 DEMOLITION PLAN NORTH LAWN COURTYARD ENLARGEMENT
L014 SITE PLAN NORTH LAWN COURTYARD ENLARGEMENT
L015 GRADING AND DRAINAGE PLAN NORTH LAWN COURTYARD ENLARGEMENT
L016 LANDSCAPE PLAN NORTH LAWN COURTYARD ENLARGEMENT
L017 SITE DETAILS
DEMOLITION
D101 FIRST FLOOR DEMOLITION PLAN
D101B FIRST FLOOR DEMOLITION PLAN - UNIT B
D102 ROOF DEMOLITION PLAN
D201 FIRST FLOOR CEILING DEMOLITION PLAN
STRUCTURAL
S001 STRUCTURAL NOTES
S101B FOUNDATION PLAN - UNIT B
S102B ROOF FRAMING PLAN - UNIT B
S201 FOUNDATION DETAILS
S301 FRAMING DETAILS
ARCHITECTURAL
A101 OVERALL FIRST FLOOR PLAN
A101B FIRST FLOOR PLAN - UNIT B
A102 ROOF PLAN
A120 ENLARGED ROOF PLAN
A121 ENLARGED KITCHEN/SERVING PLANS
A122 ENLARGED RESTROOM PLANS
A201 FIRST FLOOR REFLECTED CEILING PLAN
A201B UNIT B REFLECTED CEILING PLAN
A301 BUILDING SECTIONS AND ELEVATIONS
A411 WALL SECTIONS
A421 DETAILS
A601 DOOR SCHEDULES + ELEVATIONS
INTERIORS
I001 MATERIAL SELECTION SCHEDULE
I101 FIRST FLOOR FINISH PLAN
EQUIPMENT
FSE-1 FOOD SERVICE EXISTING CONDITIONS FLOOR PLAN
FSE-2 FOOD SERVICE EQUIPMENT FLOOR PLAN
FSE-3 FOOD SERVICE EQUIPMENT SCHEDULE
FSE-4 FOOD SERVICE ELECTRICAL FLOOR PLAN
FSE-5 FOOD SERVICE ELECTRICAL SCHEDULE
FSE-6 FOOD SERVICE PLUMBING FLOOR PLAN
FSE-7 FOOD SERVICE VENTILATION FLOOR PLAN
FSE-8 FOOD SERVICE EQUIPMENT DETAILS
PLUMBING DEMOLITION
PD101B PLUMBING DEMOLITION FIRST FLOOR PLAN - UNIT B
PD102B PLUMBING DEMOLITION ROOF PLAN - UNIT B
PLUMBING
P001B PLUMBING UNDERFLOOR PLAN - UNIT B
P101B PLUMBING FIRST FLOOR PLAN - UNIT B
P102B PLUMBING ROOF PLAN - UNIT B
P200 PLUMBING SCHEDULE
P201 PLUMBING DETAILS
NOT TO SCALE5
DEVICE ALIGNMENT GUIDELINES
3" = 1'-0"4
TYP GYP BD CONTROL JOINT DETAIL
1 1/2" = 1'-0"2
NON RATED WALL DETAIL
1 1/2" = 1'-0"1
NON RATED WALL (GYP. ONE SIDE) DETAIL
1 1/2" = 1'-0"3
SOUND WALL PARTITION (STC 45)
SHEET # SHEET NAME
MECHANICAL DEMOLITION
MD101A MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT A
MD101B MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT B
MD101C MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT C
MD101D MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT D
MD101E MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT E
MD102A MECHANICAL DEMOLITION ROOF PLAN - UNIT A
MD102B MECHANICAL DEMOLITION ROOF PLAN - UNIT B
MD102C MECHANICAL DEMOLITION ROOF PLAN - UNIT C
MD102D MECHANICAL DEMOLITION ROOF PLAN - UNIT D
MECHANICAL
M101A MECHANICAL HVAC FIRST FLOOR PLAN - UNIT A
M101B MECHANICAL HVAC FIRST FLOOR PLAN - UNIT B
M101C MECHANICAL HVAC FIRST FLOOR PLAN - UNIT C
M101D MECHANICAL HVAC FIRST FLOOR PLAN - UNIT D
M101E MECHANICAL HVAC FIRST FLOOR PLAN - UNIT E
M102A MECHANICAL HVAC ROOF PLAN - UNIT A
M102B MECHANICAL HVAC ROOF PLAN - UNIT B
M102C MECHANICAL HVAC ROOF PLAN - UNIT C
M102D MECHANICAL HVAC ROOF PLAN - UNIT D
M102E MECHANICAL HVAC ROOF PLAN - UNIT E
M103 MECHANICAL ENLARGED BOILER PLAN
M200 MECHANICAL SCHEDULES
M201 MECHANICAL DETAILS
M202 MECHANICAL NOTES & ABBREVIATONS
M300 MECHANICAL CONTROLS
M301 MECHANICAL CONTROLS
M302 MECHANICAL CONTROLS
ELECTRICAL DEMOLITION
ED101A ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT A
ED101B ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT B
ED101C ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT C
ED101D ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT D
ED101E ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT E
ED102A ELECTRICAL DEMOLITION ROOF PLAN - UNIT A
ED102B ELECTRICAL DEMOLITION ROOF PLAN - UNIT B
ED102C ELECTRICAL DEMOLITION ROOF PLAN - UNIT C
ED102D ELECTRICAL DEMOLITION ROOF PLAN - UNIT D
ELECTRICAL
E101 ELECTRICAL POWER FIRST FLOOR PLAN - OVERALL
E101A ELECTRICAL POWER FIRST FLOOR PLAN - UNIT A
E101B ELECTRICAL POWER FIRST FLOOR PLAN - UNIT B
E101C ELECTRICAL POWER FIRST FLOOR PLAN - UNIT C
E101D ELECTRICAL POWER FIRST FLOOR PLAN - UNIT D
E101E ELECTRICAL POWER FIRST FLOOR PLAN - UNIT E
E102A ELECTRICAL POWER ROOF PLAN - UNIT A
E102B ELECTRICAL POWER ROOF PLAN - UNIT B
E102C ELECTRICAL POWER ROOF PLAN - UNIT C
E102D ELECTRICAL POWER ROOF PLAN - UNIT D
E102E ELECTRICAL POWER ROOF PLAN - UNIT E
E201B ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT B
E201C ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT C
E201D ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT D
E300 ELECTRICAL SYMBOLS
E301 ELECTRICAL NOTES
E302 ELECTRICAL DEMOLITION ONE-LINE
E303 ELECTRICAL NEW ONE-LINE
E304 ELECTRICAL DETAILS
E305 ELECTRICAL SCHEDULES
E306 ELECTRICAL SCHEDULES
E307 ELECTRICAL PANEL SCHEDULES
E308 ELECTRICAL PANEL SCHEDULES
E309 ELECTRICAL PANEL SCHEDULES - RETROFIT
E401 ELECTRICAL KITCHEN PLANS
TECHNOLOGY DEMOLITION
TD101B TECHNOLOGY DEMO PLAN - UNIT B
TD101D TECHNOLOGY DEMO PLAN - UNIT D
TECHNOLOGY
T101 TECHNOLOGY LINE DIAGRAMS AND SYMBOL LEGEND
T101B TECHNOLOGY PLAN - UNIT B
T101C TECHNOLOGY PLAN - UNIT C
T101D TECHNOLOGY PLAN - UNIT D
MASONRY WALL TYPES
MARK DESCRIPTION
M2.66 6" CMU WITH 7/8" FURRING AND 5/8 GYP BD BOTH SIDES
M4 4" CMU
M8 8" CMU
M10 10" CMU
M12 12" CMU
METAL STUD WALLS
MARK DESCRIPTION
S3A 3 5/8" METAL STUDS WITH 5/8" GYP. BD. BOTH SIDES TO UNDERSIDE OF
DECK ABOVE
S3B 3 5/8" METAL STUD TO UNDERSIDE OF METAL DECK WITH 5/8" GYP. BD.
BOTH SIDES. REFER TO DETAIL FOR WHERE TO STOP GYPSUM BOARD
S3D 3 5/8" METAL STUDS WITH 5/8" GYP. BD. ONE SIDE TO UNDERSIDE OF
DECK ABOVE
S3G 3 5/8" METAL STUDS WITH 5/8" GYP. BD. ONE SIDE TO UNDERSIDE OF
DECK ABOVE
S6A 6" METAL STUDS WITH 5/8" GYP. BD. BOTH SIDES TO UNDERSIDE OF
DECK ABOVE
S6D 6" METAL STUDS WITH 5/8" GYP. BD. ONE SIDE
SYM DATE ISSUED FOR
1. CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE
EXISTING BUILDING PRIOR TO RELATED DEMOLITION
WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY
WALL, FLOOR OR CEILING INCLUDES ALL GENERAL
MECHANICAL AND ELECTRICAL ITEMS WHICH ARE A PART
OF, OR ATTACHED TO IT.
2. CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE
CONDITIONS AND DIMENSIONS AND BE RESPONSIBLE
FOR THE SAME. ADVISE ARCHITECT OF ANY AND ALL
DISCREPANCIES.
3. PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING
CONSTRUCTION AND DEMOLITION AS REQUIRED. FINISH
TO MATCH EXISTING.
4. ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.
5. PROTECT ALL EXISTING FINISHES TO REMAIN
THROUGHOUT PROJECT.
6. REFER TO DEMOLITION ELEVATIONS, SECTIONS AND
DETAILS FOR ADDITIONAL INFORMATION.
7. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND
ELECTRICAL PLANS FOR ADDITIONAL DEMOLITION NOTES.
8. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND
ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ON
SAW CUTTING AREAS
9. SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN
NEW CONSTRUCTION, IF REQUIRED.
10. AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED
ITEMS ATTACHED TO THE WALL ARE TO BE REMOVED.
SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,
TACKBOARDS, TACK STRIPS, ETC.
GENERAL DEMOLITION NOTESNO
TE
1 1
4 4 4 4 4 4 4
1 1
CAFETERIACORR
UNIT B
UNIT C
U N
IT
A
U N
IT
B
W
E X
IS
T
. B R
IC
K
C O
U R
S
IN
G
C O
O R
D
1'
7' - 0"
3' - 0"
2' - 0"
/2
W A
L L
T O
R E
M A
IN
1/
E
X
IS
T
/2
W A
L L
T O
R E
M A
IN
1/
E
X
IS
T
KITCHEN
PASSAGE
STORAGE
EMPLOYEE
LOCKERS
TLT
CORRIDOR
STORAGE
STORAGE
COOLER
STORAGESTORAGE
DN
EXIST. STAIR
TO REMAIN
REFER TO EXTERIOR ELEVATIONS AND DETAILS FOR SELECTIVE DEMO ABOVE WINDOWS
JAN.
OFFICE
NOT IN
SCOPE
REMOVE EXISTING SILL AT WINDOWS TO BE REMOVED
REMOVE EXISTING FLOOR
SLAB COORDINATE W/
NEW WORK
DEMO EXISTING HOOD
SHOWN AS LIGHT
VERTICAL LINE HATCH
PROTECT ALL RACKING TO REMAIN
DEMO EXIST.
LIMESTONE SILL
GRIND CONCRETE FLOOR AROUND
EXPOSED CRACK TO PROVIDE LEVEL
SURFACE FOR NEW FLOORING.
PHOTO OF EXIST. EXTERIOR
WINDOWS
DEMO WINDOW SYSTEMS PER NEW WORK
DEMO E.I.F.S. (APPROX 2'-0") ABOVE WINDOWS
FOR NEW WINDOW AND ENTRY SYSTEMS.
CONDUCT A STRAIGHT DEMO/CUT ACROSS
EXISTING WALL FINISH. PROTECT EXISTING TO
REMAIN ABOVE NEW OPENINGS
DEMO LOUVERS AND INFILL WITH SALVAGED
BRICK
DEMO CAST STONE SILL AND
BRICK WALL BELOW WINDOW
SYSTEMS FOR NEW ENTRY
SYSTEMS
REMOVE EXISTING BRICK
MASONRY TO ACCOMMODATE
NEW WINDOW OPENING.
A2
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
W h it eh al l M id d le S ch o o l
W h it eh al l D is tr ic t
S ch o o ls
S E li z a b e th S t, W h it e h a ll
, M I
PROJECT NO. 25 146
D101B
FIRST FLOOR
DEMOLITION PLAN -
UNIT B
10.08.26
DEMOLITION KEYED NOTES
1 REMOVE EXISTING MECHANICAL EQUIPMENT.
CORDINATE WITH MECHANICAL DRAWINGS. PREP FOR
NEW WORK.
2 REMOVE EXISTING WALL LOUVER. COORDINATE WITH
MECHANICAL DRAWINGS. PREP FOR NEW WORK
3 REMOVE EXISTING WALL AND ANY ITEMS ATTACHED TO
WALL. COORDINATE WITH MECHANICAL, ELECTRICAL,
AND PLUMBING DRAWINGS. ANY DEVICE REMOVAL
SHALL BE COORDINATED WITH OWNER.
4 REMOVE EXISTING STOREFRONT, WINDOW
TREATMENTS, AND ANY ATTACHMENTS.
5 REMOVE EXISTING DOOR AND FRAME.
6 REMOVE EXISTING ELECTRICAL EQUIPMENT.
CORDINATE WITH ELECTRICAL DRAWINGS. PREP FOR
NEW WORK.
7 REMOVE EXISTING FLOORING AND WALL BASE.
8 REMOVE PORTION OF EXISTING WALL. COORDINATE
WITH NEW WORK.
9 REMOVE EXISTING CURB. COORDINATE WITH NEW
WORK.
10 REMOVE EXISTING COUNTERTOPS AND PANEL
MOLDING. SALVAGE MOLDING FOR REUSE. CASEWORK
TO REMAIN. PREP FOR NEW SOLID SURFACE
COUNTERTOP MATERIAL.
11 REMOVE EXISTING WOOD FASCIA AS REQUIRED FOR
NEW METAL FASCIA AND NEW WOOD SUBSTRATE
INSTALL
12 REMOVE EXISTING PLUMBING FIXTURES. COORDINATE
WITH NEW WORK.
13 REMOVE EXISTING SIDEWALK PER LANDSCAPE PLANS
14 REMOVE EXISTING OVERHEAD COILING DOOR &
COUNTER
15 SAW CUT EXISTING CONCRETE FLOOR AS REQUIRED
FOR NEW UTILITY CONNECTIONS. COORDINATE WITH
NEW WORK
16 DEMO TUNNEL IN ITS ENTIRETY IN PREP FOR NEW SLAB
AND FLOOR FINISH
17 CONTRACTOR TO REMOVE, STORE, AND REINSTALL ALL
KITCHEN EQUIP SET TO BE REUSED. COORDINATE W/
OWNER AND NEW WORK
18 REMOVE EXISTING CARPET TILE AND WALL BASE.
CARPET TILE TO BE SAVED FOR RECLAIMATION AND
NOT SENT TO LANDFILL. CARPET TO BE STORED IN
STAGING AREA FOR PICK UP. CONTRCTOR IS
RESPONSIBLE FOR DEMO AND STAGING PER
MANUFACTURER GUIDELINES. COORDINATE WITH
CARPET TILE MANUFACTURER'S RECLAMATION
DEPARTMENT TO SCHEDULE PICKUP LOGISTICS
19 REMOVE EXISTING WOOD SOFFIT AND SUPPORT
FRAMING IN PREP FOR NEW
20 REFER TO ELECTRICAL FOR SCOPE AT ELECTRICAL
BOXES
NO
TE
NR
TH 1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
UNIT B
KEY PLAN
N.T.S.
SYM DATE ISSUED FOR
ROOF 17: SHINGLE ROOF REMOVAL & REPLACEMENT
INSTALL NEW UNDERLAYMENT, ICE AND WATER
SHIELD, AND ARCHITECTURAL ASPHALT SHINGLE ROOF
SYSTEM OVER PREPARED ROOF DECK. PROVIDE NEW
EAVE, RAKE, RIDGE, AND PENETRATION FLASHINGS AS
REQUIRED. REPLACE ALL ROOF VENTING
COMPONENTS, POT VENTS, ETC. INSTALL A COMPLETE
ROOF SYSTEM IN ACCORDANCE WITH PROJECT
SPECIFICATIONS AND MANUFACTURER
REQUIREMENTS. PROVIDE A FULLY WARRANTIED
SYSTEM.
COURTYARD BELOW
A301
A301
A301
A
A301
A301
ROOF 18: REMOVE AND REPLACE
INSTALL NEW ROOF ASSEMBLY INCLUDING CONTINUOUS
INSULATION, ROOF MEMBRANE, FLASHING, AND
ACCESSORIES AS REQUIRED FOR A COMPLETE AND
WARRANTABLE ROOF SYSTEM. ROOF ASSEMBLY SHALL BE
DESIGNED TO MEET APPLICABLE ENERGY CODE AND
DRAINAGE REQUIREMENTS.
VERIFY ROOF DRAIN LOCATIONS , PARAPET HEIGHTS, AND
EDGE METAL COMPATIBILITY WITH FINAL ROOF ASSEMBLY
THICKNESS AND DRAINAGE CONDITIONS. MODIFY OR
EXTEND AS REQUIRED FOR CODE COMPLIANCE AND
MANUFACTURER REQUIREMENTS
NEW METAL FASCIA WRAP OVER EXIST.
WOOD FASCIA. REPLACE ROTTED WOOD
SECTIONS AND REPLACE WITH NEW.
REMOVE AND REINSTALL METAL ROOF
EDGE FOR PROPER LAPPING. TYPICAL AT
(3) SIDES OF MECH. ROOM.
R.D.
A120
Sim
A120
A411
PROVIDE NEW PREFINISHED ALUM GUTTER, COORDINATE DOWNSPOUT LOCATIONS W/ ARCHITECT PRIOR TO INSTALL
R.D.
AHU OR RTU
ROOF DRAIN - TO REMAIN
ROOF TOP UNIT - TO REMAIN
1. ROOF WORK IS LIMITED TO AREAS INDICATED ON THE
DRAWINGS.
2. EXISTING ROOF AREAS NOT INDICATED FOR WORK SHALL
REMAIN. PATCH AND SEAL NEW PENETRATION LOCATIONS
IN EXISTING ROOF AREAS TO REMAIN.
3. TYPICAL ROOF SLOPE 1/4" / 1'-0" UNLESS NOTED
OTHERWISE.
4. PROVIDE ROOFING MANUFACTURER'S STANDARD
ROOFING TERMINATION DETAILS AT ALL PARAPETS, PRE-
MANUFACTURED ROOF EDGE SYSTEMS, CURBS, PIPE
PENETRATIONS, ETC.
5. PROVIDE CRICKETS AS REQUIRED AT MECHANICAL UNITS,
VENTS, AND SIMILAR PROJECTIONS TO PROMOTE POSITIVE
DRAINAGE.
6. ROOF DETAILS SHOWN ARE TYPICAL AND INTENDED TO
ILLUSTRATE GENERAL ROOF ASSEMBLY AND FLASHING
CONDITIONS. FINAL ROOF SYSTEM COMPONENTS AND
CONFIGURATIONS SHALL BE COORDINATED WITH
MANUFACTURER REQUIREMENTS AND FIELD CONDITIONS.
7. PROVIDE ROOF CURBS, FLASHING, AND SUPPORTS AS
REQUIRED FOR ROOFTOP EQUIPMENT AFFECTED BY ROOF
WORK. REFER TO MECHANICAL PLAN FOR LOCATIONS AND
QUANTITIES
8. ALL EXISTING ROOF PENETRATIONS REMOVED AS PART OF
THE WORK SHALL BE PATCHED AND MADE WATERTIGHT
TO MATCH ADJACENT ROOF CONDITIONS.
9. SLOPE AND DRAINAGE PATTERNS SHOWN ARE
DIAGRAMMATIC AND INTENDED TO ILLUSTRATE DESIGN
INTENT. FINAL TAPERED INSULATION LAYOUT SHALL BE BY
ROOFING CONTRACTOR.
10. SHINGLE ROOF SYSTEMS TO BE COMPLETE FULL SYSTEMS
PER MANUFACTURER REQUIREMENTS. REPLACE ALL ROOF
VENTING WITH NEW IN SAME LOCATION. PROVIDE ICE AND
WATER SHIELD, UNDERLAYMENT, ASPHALT SHINGLES
ROOF PLAN LEGEND
ROOF GENERAL NOTES
60 MIL, FULLY ADHERED, SINGLE PLY
ROOF MEMBRANE ON MIN R-30
POLYISOCYANURATE ROOF INSULATION.
INITIAL SRI : 82
EXISTING TO REMAIN, PATCH AND REPAIR
ALL NEW ROOF PENETRATIONS
LG
ND
NO
TE
E.F.
ACCU
EXHAUST FAN / HOOD - TO REMAIN
CONDENSING UNIT - TO REMAIN
M.C. MECHANICAL ROOF CURB - TO REMAIN
R.C. ROUND CURB PENETRATION - TO REMAIN
ROOF SLOPE
ASPHALT SHINGLE ROOF WITH
UNDERLAYMENT AND ICE AND
WATER SHIELD WARRANTY SYSTEM
MEMBRANE CONTINUES INTO ROOF DRAIN
ROOF DRAIN
14 GAGE COATED
STEEL BEARING PAN
FURNISHED WITH
ROOF DRAIN CLAMPING RING FURNISHED WITH ROOF DRAIN
1 1/2" METAL DECK REINFORCED AT
OPENING WITH 3"x3"x1/4" STEEL ANGLES
MEMBRANE ROOFING ON RIGID INSULATION,
TAPER TO DRAIN
/2
CENTER LINE OF VALLEY OF FINISHED ROOF
1" THICK INSULATION
PIPE INSULATION ON
DRAIN LEADERS
ROOF DECK
ROOF INSULATION
FLASHING PER ROOF
MANUFACTURERS
STANDARD DETAILS
VENT PIPE
CONTINOUS SEALANT
SINGLE PLY ROOFING
TREATED NAILERS AS REQUIRED
ROOF DECK
CANT STRIP
11/2" RIGID INSULATION
PREFAB ROOF CURB
COUNTER FLASHING WITH
APPROVED SEALING
WASHER AND FASTENER
@ 6" O.C.
ROOF MOUNTED EQUIPMENT
TREATED 2"x4" NAILER
M
IN
LAP SEALANT
ROOF MEMBRANE
ALUMINUM DRIP EDGE TO MATCH EXISTING PROFILE
RIGID POLYISO INSULATION (BASE &
TAPERED) OVER EXISTING ROOF DECK.
ROOF MEMBRANE
EXTEND MEMBRANE PER MFR. REQUIREMENTS
NEW 1/2" COVER BOARD (HIGH DENSITY
RIGID INSUL.) OVER TAPERED INSULATION
EXISTING WALL
11"
EXISTING ROOF DECK
EXISTING ROOF,
FIELD VERIFY
DUCT ROUTING
THROUGH EXISTING
WALL, PROVIDE A
WATER TIGHT
PENETRATION
NEW CMU WALL
FOR RESTROOMS
B
A ELEVATION B SECTION C PLAN
2 1/2"x1/2" FLAT
STOCK
GALVANIZED
3/4" -
GALVANIZED
RUNGS
1' - 6"
7"
1'
BOTTOM
OF ROOF
DECK
2 1/2"x1/2"
FLAT STOCK
GALVANIZE
D
ANCHOR TO
WALL
@ 3'-0" O.C.
VERTICAL
MAXIMUM3/4" -
GALVANIZED
RUNGS
FLOOR/RO
OF
LADDER SAFETY SYSTEM
(LADDERS ABOVE 24FT):
PROVIDE A COMPLETE SYSTEM
INCLUDING AUTOMATIC
PERSONAL FALL ARRESTOR
CABLE SLEEVES, INTEGRAL
SWIVEL, CARABINEERS, BOTTOM
BRACKET WITH DUAL FUNCTION
TENSIONER, TOP BRACKET WITH
SHOCK ABSORBER, 3/8"
STAINLESS STEEL CABLE AND
CABLE TERMINATION KIT.
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
W h it eh al l M id d le S ch o o l
W h it eh al l D is tr ic t
S ch o o ls
S E li za b e th S t, W h it e h a ll
, M I
PROJECT NO. 25 146
A120
ENLARGED ROOF PLAN
10.08.26
NR
TH 1/8" = 1'-0"1
ENLARGED ROOF GYM
NR
TH 1/8" = 1'-0"2
ENLARGED ROOF MECHANICAL
1 1/2" = 1'-0"3
TYPICAL ROOF DRAIN DETAIL
1 1/2" = 1'-0"8
TYPICAL ROOF PENETRATION DETAIL
1 1/2" = 1'-0"5
TYPICAL ROOF CURB DETAIL
1 1/2" = 1'-0"4
PARAPET CAP MEMBRANE DETAIL1
1/4" = 1'-0"7
ROOF LADDER DETAIL W/ SIDE RAIL EXTENSION
1/4" = 1'-0"6
ROOF SECTION DETAIL DUCT/AIR HANDLER
SYM DATE ISSUED FOR
5/8" GYP. BD. - PAINT
3-5/8" CFMF AT 16" O.C.
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
S.S FLASHING W/ HEMMED
EDGE (YORK 304 SA)
SELF-ADHERED THROUGH
WALL FLASHING
SHIM, SEALANT AND
BACKER ROD AROUND
PERIMETER, BOTH SIDES
EXIST. WALL, F.V.
EXIST. BEAM BOX-OUT,
REMOVE EXIST. WD
FINISH AND WRAP W/
DRYWALL, PAINT
FIRST FLOOR
F.F. : 100' - 0" 1
EXIST. CONC. FOUNDATION,
F.V.
EXIST. CMU, F.V.
EXIST. SLOPE GRADE AWAY
FROM BLD - SEE SITE, F.V.
CAST STONE W/ SLOPED
TOP AT SILL, COLOR TO
MATCH EXIST.
WEEP VENTS AT 32" O.C. AT
TOP OF OPENING
INFILL CAVITY W/ RIGID
INSULATION
SELF-ADHERED THROUGH
WALL FLASHING
S.S FLASHING W/ HEMMED
EDGE (YORK 304 SA)
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
WINDOW SILL - SEE FINISH
PLANS
CAFETERIA
B104
FLUID APPLIED AIR/VAPOR
BARRIER
F.T. 1X WOOD BLOCKING 7
/8
3 5/8"PREFIN. ALUM. SILL
FLASHING
EXISTING EIFS SYSTEM, SEE
EXTERIOR ELEV. FOR NEW
WORK
5/8" GYP. BD. - PAINT
3-5/8" CFMF AT 16" O.C.
SHIM, SEALANT AND
BACKER ROD AROUND
PERIMETER, BOTH SIDES
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
ALUM DOOR AND FRAME -
SEE DOOR SCHED.
PATCH AND REPAIR AS
REQUIRED PRIOR TO PAINT
EXIST. WALL, F.V.
SELF-ADHERED THROUGH
WALL FLASHING
S.S FLASHING W/ HEMMED
EDGE (YORK 304 SA)
FIRST FLOOR
F.F. : 100' - 0" 1
1" IGU
ALUM DOOR AND FRAME -
SEE DOOR SCHED.
THRESHOLD SET IN MASTIC
FOR WATERTIGHT SEAL
EXIST. CONC. FOUNDATION,
F.V.
DOWEL NEW SLAB TO
EXIST. FOUNDATION TO
PREVENT HEAVING
SITE CONCRETE, SLOPE
AWAY FROM BLD. - SEE
SITE
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
PREFIN. ALUM. SILL
FLASHING
WINDOW SILL - SEE FINISH
PLANS
EXIST. MASONRY WALL, F.V.
EXIST. CAST STONE SILL, F.V.
FLUID APPLIED AIR/VAPOR
BARRIER
SHIM, SEALANT AND
BACKER ROD AROUND
PERIMETER, BOTH SIDES
CAFETERIA
B104
ALUM DOOR AND FRAME -
SEE DOOR SCHED.
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
SELF-ADHERED THROUGH
WALL FLASHING
SHIM, SEALANT AND
BACKER ROD AROUND
PERIMETER, BOTH SIDES
EXIST. MASONRY WALL, F.V.
WEEP VENTS AT 32" O.C. AT TOP OF WALL
FACE BRICK, MATCH EXIST.
3" RIGID INSULATION - R11.4 MIN.
FLUID APPLIED AIR/VAPOR BARRIER
8" CMU
EXISTING STEEL - F.V.
SINGLE PLY ROOF
MEMBRANE ON 1/2" GYP
SHEATHING COVER BD
OVER POLYISO ROOF
INSULATION ON AIR/VAPOR
BARRIER OVER 1/2" GYP
SHEATHING
EXISTING ROOF DECK - F.V.
CONDITION
PREFIN. ALUM. PLANK SOFFIT OVER AIR
BARRIER AND 5/8" PLYWD SHEATHING,
PROVIDE VENTING AT EACH END
THERMALLY BROKEN ADJUSTABLE
MASONRY ANCHOR 16" O.C. VERT. AND
16" O.C. HORIZ.
3-5/8" CFMF AT 16" O.C.
PREFIN METAL ROOF
EDGE, COLOR TO MATCH
EXIST.
F U
L L
I N
S U
L . C
O V
E R
A G
E
1'
PREFIN. ALUM. FASCIA -
.040" THICKNESS MIN.,
COLOR TO MATCH EXIST.
FLUID APPLIED AIR/VAPOR
BARRIER
F.T. 3/4" PLYWOOD SHEATHING
LAP ROOF MEMBANE OVER
ROOF EDGE, UNDER CAP
MECH.
B103
WALL-WASH LIGHT
FIXTURE - SEE ELECTRICAL
MECH.
B103
FACE BRICK, MATCH EXIST.
3" RIGID INSULATION - R11.4
MIN.
FLUID APPLIED AIR/VAPOR
BARRIER
CAVITY FILTER DRAINAGE
MESH
WEEP VENTS AT 32" O.C. AT
TOP OF OPENING
REMOVE AND REWORK
GRADE AS REQUIRED FOR
NEW BRICK INSTALL.
VERIFY GRADE WILL
COVER FIRST COURSE OF
BRICK AS SHOWN AND
WILL SLOPE AWAY FROM
BLD.
STEEL ANGLE FOR
MASONRY SUPPORT - SEE
STRUCT.
EXIST. CONC. FOUNDATION,
F.V.
S.S FLASHING W/ HEMMED
EDGE (YORK 304 SA)
FLEXIBLE THROUGH WALL
FLASHING
8" CMU
W/ EXIST. CONDITIONS
1' - 4" +/- COORD.
1"
M
IN
C O
V E
R A
G E
REMOVE EXISTING
LIMESTONE SILL
AND INFILL W/
CONC OR CMU.
SECURE TO EXIST.
CONC.
MECH.
B103
W
E X
IS
T
. C O
N D
IT
IO
N S
1'
C O
O R
D
FACE BRICK, MATCH EXIST.
3" RIGID INSULATION - R11.4
MIN.
FLUID APPLIED AIR/VAPOR
BARRIER
8" CMU
SELF-ADHERED THROUGH
WALL FLASHING
EXIST. MASONRY WALL, F.V.
FIRST FLOOR
F.F. : 100' - 0"1
CAVITY FILTER DRAINAGE
MESH
WEEP VENTS AT 32" O.C. AT
TOP OF OPENING
SELF-ADHERED THROUGH
WALL FLASHING
S.S FLASHING W/ HEMMED
EDGE (YORK 304 SA)
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
5 1/2"
DISH WASHING
B106
EXIST. CONC. FOUNDATION,
F.V.
FILL COLLAR JOINT W/
MORTAR
3" RIGID INSULATION - R11.4
MIN.
FLUID APPLIED AIR/VAPOR
BARRIER
FACE BRICK, MATCH EXIST.
WEEP VENTS AT 32" O.C. AT
TOP OF OPENING
CAST STONE W/ SLOPED
TOP AT SILL, COLOR TO
MATCH EXIST.
S.S FLASHING W/ HEMMED
EDGE (YORK 304 SA)
SELF-ADHERED THROUGH
WALL FLASHING
8" CMU
WINDOW SILL - SEE FINISH
PLANS
SHIM, SEALANT AND
BACKER ROD AROUND
PERIMETER, BOTH SIDES
THERMALLY BROKEN
ADJUSTABLE MASONRY
ANCHOR 16" O.C. VERT. AND
16" O.C. HORIZ.
1' - 4"
F.T. 2X4 WOOD BLOCKING
ALIGN W/ EXIST.
CMU WALL
DAMPPROOFING AT NEW
FOUNDATIONS
PREFIN. ALUM. SILL
FLASHING
S.S FLASHING W/ HEMMED
EDGE (YORK 304 SA)
DISH WASHING
B106
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
SUSPENDED ACOUSTIC
GRID CEILING SYSTEM - SEE
CLG PLANS
EXISTING EIFS SYSTEM, SEE
EXTERIOR ELEV. FOR NEW
WORK
SEALANT AND BACKER
ROD
T Y
P
1"
/8
9 1/2"
1/
/4
F.T. 2X4 WOOD BLOCKING
F.T. 1X WOOD BLOCKING
5/8" GYP. BD. - PAINT
6" CFMF AT 16" O.C.
SUSPENDED ACOUSTIC
GRID CEILING SYSTEM - SEE
CLG PLANS
INTERIOR SUSPENDED
BACKLIT SIGNAGE - SEE
CLG PLANS
SUSPENDED ACOUSTIC
BAFFLE PLANK SYSTEM -
SEE CLG PLANS
STRIP LIGHT FIXTURE - SEE
ELECTRICAL
5/8" GYP. BD. - PAINT
WOMENS
B102
CORR
B100
DOOR AND FRAME - SEE
DOOR SCHED.
8" CMU - BULLNOSE
EXIST. MASONRY WALL, F.V.
SEE FLOOR PLAN FOR
ADDITIONAL NOTES
SEALANT AND BACKER
ROD
6" +/- 6" +/-
5/8" GYP. BD. W/ METAL
WRAP - SEE FINISH PLANS
EXISTING STEEL - F.V.
3-5/8" CFMF - INSTALL
TIGHT TO COL.
5/8" GYP. BD. W/ METAL
WRAP - SEE FINISH PLANS
3-5/8" CFMF - INSTALL
TIGHT TO COL.
EXISTING STEEL - F.V.
6" +/- 6" +/-
BOOTH BELOW -
SEE FINISH PLANS
ALUM STOREFRONT
SYSTEM - SEE FRAME ELEV.
EXIST. CMU LEDGE AND
NEW SILL BELOW
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
W h it eh al l M id d le S ch o o l
W h it eh al l D is tr ic t
S ch o o ls
S E li z a b e th S t, W h it e h a ll
, M I
PROJECT NO. 25 146
A421
DETAILS
10.08.26
1 1/2" = 1'-0"10
NORTH WALL TOP OF WALL
1 1/2" = 1'-0"6
NORTH WALL BASE OF WALL
1 1/2" = 1'-0"9
ALUM DOOR HEAD DETAIL
1 1/2" = 1'-0"1
ALUM THRESHOLD DETAIL
1 1/2" = 1'-0"2
SOUTH WALL STOREFRONT SILL DETAIL
1 1/2" = 1'-0"5
PLAN DETAIL AT ALUM JAMB
1 1/2" = 1'-0"11
TOP OF WEST MECHANICAL WALL
1 1/2" = 1'-0"3
BASE OF WEST MECHANICAL WALL
1 1/2" = 1'-0"7
PLAN DETAIL AT WEST MECHANICAL WALL
1 1/2" = 1'-0"4
NORTH WALL INFILL BASE OF WALL
1 1/2" = 1'-0"8
NORTH WALL INFILL TOP OF WALL
1 1/2" = 1'-0"12
CAFETERIA CLG DETAIL
1 1/2" = 1'-0"13
DETAIL AT MASONRY OPENING
1 1/2" = 1'-0"14
SOUTH COL WRAP
1 1/2" = 1'-0"15
NORTH COL WRAP
SYM DATE ISSUED FOR
A2 11.06.26 BID ADD #02
A2
1. REFER TO SHEET I001 FOR ADDITIONAL INFORMATION ON
INTERIOR MATERIALS.
2. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH AND
HEIGHTS.
3. REFER TO DOOR SCHEDULE FOR FINISH ON DOORS AND FRAMES.
4. FINISH TAGS APPLY TO LIKE MATERIALS IN ENTIRE ROOM. I.E.
CASEWORK TAG MAY ONLY CALLOUT ONE RUN OF CASEWORK,
BUT ALL CASEWORK IN ROOM RECEIVE THE SAME FINISHES,
UNLESS TAGGED DIFFERENTLY.
5. CASEWORK FINISH TAGS DO NOT APPLY TO CUSTOM MILLWORK
PIECES. REFER TO ENLARGED MILLWORK DETAILS FOR FINISH
MATERIALS.
6. WALL MOUNTED DIFFUSERS, GRILLES, ACCESS PANELS,
ELECTRICAL PANELS, ETC. ARE TO BE PAINTED WITH AN OIL-BASED
PAINT TO MATCH THE ADJACENT WALL FINISH.
7. CEILING ACCESS PANELS ARE TO BE PAINTED TO MATCH
ADJACENT CEILING FINISH.
8. ALL DRYWALL OUTSIDE CORNERS TO RECEIVE CORNER GUARDS
(CG01). INSTALL BOTTOM EDGE OF CORNER GUARD AT TOP OF
WALL BASE, UNLESS OTHERWISE NOTED.
9. ALL FLOORING TRANSITIONS TO OCCUR CENTERED UNDERNEATH
FLOOR LEAF.
10. WINDOW TREATMENTS TO BE REPLACED IN CLASSROOMS ONLY.
ALL OTHER AREAS EXISTING TO REMAIN.
11. REFER TO SHEET I001 FOR MATERIAL TRANSITIONS.
12. REFER TO SPECIFICATION FOR MORE INFORMATION.
13. REFER TO FLOOR PLANS, EXTERIOR ELEVATIONS AND FRAME
TYPES FOR HEIGHT AND WIDTH OF OPENINGS.
14. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION
GENERAL NOTES - INTERIORSNO
TE
GENERAL CASEWORK/MILLWORK NOTESNO
TE
1. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION.
2. FILLER PANELS SHALL BE NO LESS THAN 2" WIDE, UNLESS NOTED
OTHERWISE.
3. REFER TO FLOOR FINISH PLANS FOR CASEWORK AND
COUNTERTOP FINISHES BY ROOM.
4. FINISH ANY EXPOSED END PANELS, UNDERSIDE OF CABINETS OR
OPEN CABINETS, WITH PLASTIC LAMINATE SPECIFIED FOR FRONTS
IN THAT ROOM.
5. ALL VERTICAL AND HORIZONTAL EXPOSED AND SEMI-EXPOSED
SURFACES TO BE FINISHED WITH BODY PLASTIC LAMINATE.
6. PATTERN OR GRAIN DIRECTION TO BE VERTICAL ON DOORS AND
HORIZONTAL ON DRAWERS - PER AWI STANDARDS, UNLESS NOTED
OTHERWISE.
7. 3MM EDGE BANDING TO MATCH LAMINATE SELECTION. SQUARE
EDGE.
1. PROVIDE SOFT JOINT WHERE TILE MEETS CEILING/ DOOR FRAMES.
2. PROVIDE DILEX COVE TRIM AT BASE OF TILED WALLS.
3. REFER TO MATERIAL TRANSITION DETAILS ON SHEET 1001 FOR
MORE INFORMATION AND LOCATIONS NECESSARY.
4. REFER TO MATERIAL SELECTION SCHEDULE FOR GROUT
SELECTIONS AND JOINT WIDTHS (ACCORDING TO TILE SELECTION)
TILE GENERAL NOTESNO
TE
± 1/8" THICK SHEET VINYL OR RUBBER TILE
CARPET TILE
JOHNSONITE SLIMLINE TRANSITION,
FINISH:_______
PORCELAIN TILE TO CARPET TILE (PT - CPT)
PORCELAIN TILE
THINSET OR MORTAR
SCHLUTER RENO-TK - FINISH:_______
PORCELAIN TILE TO SEALED OR POLISHED
CONCRETE (PT - SC - PC)
PORCELAIN TILE
THINSET OR
MORTAR
SCHLUTER RENO-U - FINISH:_______
SEALED OR POLISHED
CONCRETE
PORCELAIN TILE TO SHEET VINYL (PT - SV)
PORCELAIN TILE
THINSET OR MORTAR
SCHLUTER RENO-U - FINISH:_______
± 1/8" THICK SHEET VINYL OR RUBBER TILE
PORCELAIN TILE TO SHEET VINYL (PT - SV)
PORCELAIN TILE
THINSET OR MORTAR
SCHLUTER RENO-V - FINISH:_______
± 1/4" THICK SHEET VINYL
PORCELAIN TILE TO RUBBER TILE (PT - RBT)
CARPET TILE TO SHEET VINYL (CPT - SV)
CARPET TILE TO RUBBER TILE (CPT - RBT)
SCHLUTER QUADEC - TRENDLINE
COLOR:_______, GROUT FILL VOID
WING WALL OR
OUTSIDE
CORNER
THINSET OR MORTAR
PORCELAIN OR
CERAMIC TILE, TYP.
SCHLUTER DILEX-BWA
"SOFT JOINT"; FINISH:_______
THINSET OR MORTAR
PORCELAIN OR
CERAMIC TILE, TYP.
CEILING, DOOR FRAME, OR
OTHER FIXED BUILDING
ELEMENT
WALL TILE OUTSIDE
CORNER
WALL TILE SOFT
JOINT
PORCELAIN TILE WALL BASE (PTB) AT PAINTED
WALLS
CUT PORCELAIN TILE
BASE
SCHLUTER DILEX-AHK - FINISH:_______
PORCELAIN FLOOR TILE -
REFER TO SPECIFICATIONS
SCHLUTER QUADEC - COLOR:_______
GROUT FILL VOID
PAINTED GYPSUM BOARD WALL PER
FINISH PLAN
SCHLUTER DILEX-BWA
"SOFT JOINT"; FINISH:_______
THINSET OR MORTAR
PORCELAIN OR
CERAMIC TILE, TYP.
COLUMN OR OTHER FIXED
BUILDING ELEMENT
FLOOR TILE SOFT
JOINT
TILED WALLS WITHOUT TILE
BASE
FLOOR FINISH OTHER
THAN TILE
CERAMIC OR PORCELAIN
WALL TILE (INCLUDING
MOSAICS)
SCHLUTER DILEX-AHK - FINISH:_______
SHEET NUMBER
SHEET NAME
REVISIONS
ISSUE DATE
©2026
SHEET SIZE
30 x 42
W h it eh al l M id d le S ch o o l
W h it eh al l D is tr ic t
S ch o o ls
S E li za b e th S t, W h it e h a ll
, M I
PROJECT NO. 25 146
I001
MATERIAL SELECTION
SCHEDULE
10.08.26
MATERIAL SELECTION SCHEDULE
ABBREV ITEM MANUFACTURER PATTERN COLOR PRODUCT NO. SIZE REMARKS PRODUCT REP.
ACB01 ACOUSTIC CEILING BAFFLES MDC ZINTRA STICKS BUNDLES - WIDE WHITE OAK ZTR4911PW1S 37.5” W X 108”
H X 2.4” D
SUSPENSION INSTALL, 8'8" AFF
ACP01 ACOUSTIC CEILING PANEL ARMSTRONG CORTEGA ANGLED TEGULAR EDGE WHITE 704A 24" x 24" BUILDING STANDARD, 15/16" GRID
ACP02 ACOUSTIC CEILING PANEL USG CEILINGS RADAR SQUARE EDGE WHITE 2410 24" X 48" BUILDING STANDARD
ACP03 ACOUSTIC CEILING PANEL ARMSTRONG KITCHEN ZONE WITH 15/16" GRID WHITE 673 24" X 24"
AL01 ANODIZED ALUMINUM
STOREFRONTS
DARK BRONZE VERIFY EXISTING CONDITIONS AND MATCH ADJACENT FINISH
AL01 ALT ANODIZED ALUMINUM
STOREFRONTS
BLACK VERIFY EXISTING CONDITIONS AND MATCH ADJACENT FINISH
CG01 CORNER GUARDS INPRO CORNER GUARDS TAPE ON CORNER GUARDS (WITHOUT TAPE) 90
DEGREE
BRUSHED SILVER 11248E-5E025 1-1/2" X 48" INSTALL WITH HEAVY-DUTY ADHESIVE AT ALL OUTSIDE GYP.
CORNE…
This is the start of the file's text. The full file is on GovTribe.