01 - Pure Architects Addendum 02.pdf

PDF 3 MB Posted

Attached to
WDS Bond Proposal Phase 1- Ealy, Middle School, Shoreline
Solicitation number
RFP WDS 270000000188 3
Issued by
Oakland County, Michigan

About this file

This is an Addendum to the architectural services contract for the WDS Bond Proposal Phase 1 project, involving Ealy Middle School and Shoreline facilities in Michigan. The addendum modifies the original scope of work and contract terms established with Pure Architects for the design and planning services related to the bond-funded school construction project. The document serves to clarify, revise, or expand upon specific requirements, deliverables, or conditions outlined in the initial contract agreement for the Phase 1 design development of these educational facilities.

The addendum addresses modifications to the architectural services scope, which may include adjustments to design phases, fee structures, schedule revisions, or additional services required by the school district. As a supplemental document to the primary contract, this addendum incorporates changes by reference or explicit language and becomes part of the binding agreement between the district and Pure Architects, ensuring both parties operate under updated terms and conditions for the completion of design work on the Ealy Middle School and Shoreline projects within the WDS Bond Proposal Phase 1 initiative.

View the file

Other files

File Type Posted
01a - Pure Architects Bid Addendum 01.pdf PDF
01b - Millies Engineering Bid Addendum 01.pdf PDF
06 - Middle School Asbestos Survey 20260506.pdf PDF
03 - Section 012300 - Alternates.pdf PDF
20261021 Phase 1 Project Schedule.pdf PDF
08 - Middle School OSHA Paint Sampling 20260914.pdf PDF
04 - Whitehall Middle School Interior Logistics Plan.pdf PDF
02 - Section 002416 Bid Category Specific Notes.pdf PDF
26 0930 WDS Ealy CD Drawings.pdf PDF
00 - Addendum 02 - Summary.pdf PDF
26 0930 WDS MS CD Drawings.pdf PDF
00 - Addendum 01 - Summary.pdf PDF
26 0930 WDS Phase 1 - Project Manual_Part1.pdf PDF
Ealy Site Logistics Plan.pdf PDF
26 0930 WDS Phase 1 - Project Manual_Part2.pdf PDF
02 - Section 002416 - Bid Categories.pdf PDF
04 - Pre-bid RFIs Addendum 2.pdf PDF
07 - Ealy Asbestos Survey 20260501.pdf PDF
10 - 20261029 Pre-Bid Meeting.pdf PDF
05 - Middle School Existing Tunnel Location.pdf PDF
20261021 Clark Construction Project Manual.pdf PDF
09 - Ealy OSHA Paint Sampling 20260914.pdf PDF
Shoreline Logistics Plan.pdf PDF
11 - Pre-Bid RFIs Addendum 01.pdf PDF
03 - Section 012300 - ALTERNATES.pdf PDF
26 0930 WDS Shoreline CD Drawings.pdf PDF
WDS Middle School Logistics Plan.pdf PDF
26 0930 WDS Phase 1 - Project Manual_Part3.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

-./0- -12/34567895-:8;;523-<=;->/=372?678/=-@<=<A52-

���B%���$� ��������,� ��������C�����D�����,�����+�

-.E83-<;;5=;?F-G/2F3-<-4<27-/G-7E5-6/=372?678/=-;/6?F5=73-<=;-F/;8H53-7E5-/28A8=<I-

-6/=372?678/=-;/6?F5=73J-;<75;-KLMNKMOKOPM-.E5-<;;5=;?F-3E<II-Q56/F5-<-4<27-/G-7E5-

->/=72<67-R/6?F5=73-<=;-3E<II-Q5-7<S5=-8=7/-<66/?=7-8=-4254<28=A-7E5-Q8;M-.E5-T/2SJ-8=-

-5<6E-35678/=J-3E<II-Q5-8=-<66/2;<=65-T87E-7E5-/28A8=<I-U4568H6<78/=3-?=I533-=/75;J-

-34568H6<IIV-8=-7E83-<;;5=;?FM-W6S=/TI5;A8=A-7E5-2565847-/G-7E83-<;;5=;?F-83-25X?825;-

-/=-7E5-:8;-Y/2FM-Y<8I?25-7/-;/-3/-F<V-3?QZ567-:8;;52-7/-;83X?<I8H6<78/=M-

-]M- -̂/=5-

-]M- -̂/=5-

�_��D��

-]M- -̀<IV-

-<M--aKKO0-W;;5;-WI752=<75-I837-7/-6//2;8=<75-T87E-7E5-H=83E-I5A5=;-

-QM--R]K]>0-b5F/95;-=/75-cd-G2/F-25372//F3M-

-6M--WOK]0--@/;8H5;--5378F<75;--658I8=A--25F/9<Ie254I<65F5=7--<25<3--7/--6//2;8=<75--T87E--@ 1̀-

-<Q/95-658I8=A-T/2SM-

-OM--@8;;I5-U6E//I0-

-<M--aKKO0-W;;5;-Wf-7/-7E5-WI752=<753-g5A5=;-7/-6//2;8=<75-T87E-7E5-H=83E-I5A5=;-

-QM--R]K]:0-b5F/95;-<25<-/G-3I<Q-;5F/-

-6M--W]OK0-b//G-;57<8I-25G525=65-25F/95;M-

-;M--WdO]0-

-8M--R57<8I-cO0-Y8h5;-A2<4E863-

-88M--R57<8I--cd--i--cP0--W;;5;--<--=/75--6<II8=A--G/2--425H=83E5;--38II--j<3E8=A--7/--F<76E--;57<8I-

-cO-

-5M--kKK]0->E<=A5;-1.K]lWd-7/-��m (n�!�-7/-6//2;8=<75-T87E-7E5-<I752=<75-I837-/=-aKKO-

-GM- -U]K]:0-o4;<75;-=/753-G/2-A5/G/<F-<=;-6/=62575-7E86S=533M-

-TTTM4?25<26E875673M6/F-

***�+,-��-���.��./�� 0

TYPICAL SYMBOLS & REFERENCESLG

ND

REFERENCE CALLOUT SYMBOL

A101

SIM

DETAIL NUMBER

SHEET NUMBER

EXTERIOR ELEVATION

REFERENCE BUBBLE A101

A ELEVATION LETTER

BUILDING SECTION SYMBOL

A101

SIM

SECTION NUMBER

SHEET NUMBER

INTERIOR ELEVATION

REFERENCE BUBBLE

A101

SHEET NUMBER

A

A

A

A

SIMILAR CONDITION

OPP

OPPOSITE CONDITION

ELEVATION LETTER

SIMILAR CONDITION

OPP

OPPOSITE CONDITION VIEW DIRECTION

1. THE OWNER RESERVES THE RIGHT TO REMOVE OR

MODIFY SCOPE ITEMS PRIOR TO COMMENCEMENT OF

CONTRACTED WORK.

2. OWNER MAY ACCEPT BASE BID OR ALTERNATE AT TIME

OF AWARD.

3. ALL EXISTING CONDITIONS SHALL BE FIELD VERIFIED

PRIOR TO COMMENCEMENT OF WORK.

4. EXISTING ROOF CONDITIONS MAY VARY FROM

INFORMATION SHOWN. ADDITIONAL REPAIRS OR

MODIFICATIONS MAY BE REQUIRED BASED ON FIELD

CONDITIONS AND SHALL BE COORDINATED WITH THE

OWNER PRIOR TO PROCEEDING.

5. COORDINATE ROOF WORK WITH ONGOING BUILDING

OPERATIONS.

6. CONTRACTOR SHALL PROTECT EXISTING BUILDING, ROOF

AREAS, AND INTERIOR SPACES FROM WATER INTRUSION

DURING CONSTRUCTION.

GENERAL ARCHITECTURAL NOTESNO

TE

S

NOTE:

MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED

OTHERWISE. SWITCHES (LOCATE ON LATCH SIDE, IF

SWITCH OR DEVICE CANNOT BE

LOCATED ON LATCH SIDE, LOCATE

ONE DOOR LEAF WIDTH AWAY ON

HINGE SIDE) STACK UP TO 2 HIGH

DEVICES TO KEEP WITHIN ADA REACH.

DOOR

LOW

DEVICES

RECEPTACLEVOICE/DATA

MASONRY COURSING

(WHERE APPLICABLE)

F.A. PULL STATION

THERMOSTAT

F.A. AUDIO/VISUAL

ALIGNMENT NOTES

• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.

• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.

• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.

• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT

• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.

F

R O

M F

L O

O R

O R

L A

N D

IN

G

F R

O M

F L

O O

R O

R L

A N

D

IN

G

CARD READER

6' - 0" MIN.

4" MAX

CAMERAS, CLOCKS,

WALL OCCUPANCY

SENSORS

WHITE BOARD (WHERE

APPLICABLE - VERIFY WITH

DETAILS/PLANS PROPER

INSTALL HEIGHT) CENTER ANY

SINGLE DEVICE WITH CENTER

OF WHITE BOARD

ANY DEVICES

SHOWN OVER

DOOR TO BE

CENTERED.

EQ EQ

EQ EQ

F

R O

M F

L O

O R

O R

L A

N D

IN

G

SHORT THROW

PROJECTOR WHERE

APPLICABLE

~12"

MAX TWO DEVICES IN

ONE HIGHER MOUNT

LOCATION, PROVIDE RFI

IF MORE DEVICES ARE

NECESSARY

WHEN DEVICES ARE WITHIN DIMENSION,

STACK HIGH/LOW VERTICALLY AND GROUP

DEVICES AT SAME HEIGHT. UNLESS

DEVICES IS PART OF TECHNOLOGY DETAIL

GROUPING OR SERVING A FURNITURE

GROUP.

CASEWORK, COORDINATE DEVICE

BOTTOM TO BE 2" OVER

BACKSPLASH OR OVER

COUNTERTOP (IF NO BACKSPLASH).

FOR LARGE FORMAT TILE, ALIGN

EDGE OF DEVICE WITH HORIZONTAL

GROUT LINE CLOSEST TO

COUNTERTOP.

COORDINATE OUTLET LOCATIONS

WITH GROUT LINES, EDGE OF

DEVICE ON GROUT LINE IF POSSIBLE.

COORDINATE WITH INTERIOR

DESIGN DRAWINGS.

S

TYPICAL COLUMN

ENCLOSURE, CHASE

OR BUMP-OUT WITH

DEVICES INDICATED

IN PLANS.

EQ EQ

M A

X

4" MAX.

M

IN

PROTRUDING

OBJECTS

REDUCED VERTICAL

CLEARANCE

WATER CLOSET &

LAVATORY CLEARANCE

403.5

CLEAR WIDTH

ACCESSIBLE ROUTE

TRANSFER SHOWER

CLEARANCE

404.2.3.2(A)

FRONT APPROACH PULL SIDE

*IF BOTH CLOSER AND LATCH

ARE PROVIDED

404.2.3.2(B)

FRONT APPROACH PUSH SIDE

*IF BOTH CLOSER AND LATCH

ARE PROVIDED - NEW

BUILDINGS

404.2.3.2(E)

HINGE APPROACH PULL SIDE

404.2.3.2(F)

HINGE APPROACH PUSH SIDE

*48" MIN IF BOTH CLOSER AND

LATCH ARE PROVIDED

404.2.3.2(G)

LATCH APPROACH PULL SIDE

*54" IF CLOSER IS PROVIDED

404.2.3.2(H)

LATCH APPROACH PUSH SIDE

*48" IF CLOSER IS PROVIDED

CHANGES IN LEVEL

NOTE:

INFORMATION SHOWN IS TAKEN FROM THE AMERICAN

NATIONAL STANDARD INSTITUTE (ANSI) AND IS FOR

REFERENCE ONLY AS DESCRIBED IN: ANSI ICC A117.1-2017

M A

X

M

IN

" C L

E A

R

M

IN

CLEAR

60" MIN.

M

IN

MIN.

30"

MIN.

36"

MIN.

32"

M A

X

M

IN

M A

X

S E

A T

W

L

L

BACK

WALL

36"

48"

M

IN

MIN.

18" *

M

IN

MIN.

12" *

M

IN

42" MIN.

M

IN

MIN.

22"

M

IN

MIN.

24"

M

IN

MIN.

24"

1/

M A

X

1/

M A

X

1/

M A

X

1/

M A

X

ACCESSIBLE BUILDING CLEARANCESLG

ND

MIN.

15"

MIN.

16"

M

A X

M

IN

8" MIN

6" MIN 11"

MAX

25"

M

IN

KNEE

CLEARANCE

ø

304.3.1.1

NEW BUILDING

TURNING RADIUS

ø

304.3.1.2

EXISTING BUILDING

TURNING RADIUS

ø

OVERLAP AREA

304.3.2

T-SHAPED TURNING RADIUS

NEW BUILDINGS - OPTION 1

68" MIN.

M

IN

16" MIN. 36" MIN. 16" MIN.

M

IN

M

IN

304.3.2

T-SHAPED TURNING RADIUS

NEW BUILDINGS - OPTION 2

64" MIN.

M

IN

11" MIN. 42" MIN. 11" MIN.

M

IN

M

IN

304.3.2

T-SHAPED TURNING RADIUS

NEW BUILDINGS - OPTION 3

64" MIN.

M

IN

12" MIN. 40" MIN. 12" MIN.

M

IN

M

IN

304.3.2.2

T-SHAPED TURNING RADIUS

EXISTING BUILDINGS

60" MIN.

M

IN

12" MIN. 36" MIN. 12" MIN.

M

IN

M

IN

305.3.1

NEW BUILDING

CLEAR FLOOR SPACE

52" MIN.

M

IN

305.3.2

EXISTING BUILDING

CLEAR FLOOR SPACE

48" MIN.

M

IN

404.2.3.2(C)

FRONT APPROACH PUSH SIDE

*IF BOTH CLOSER AND LATCH

ARE PROVIDED - EXISTING

BUILDINGS

M

IN

MIN.

12" *

404.2.3.2(D)

HINGE APPROACH PULL SIDE

M

IN

36" MIN.

ALTERNATE LISTLG

ND

A3: REMOVE AND REPLACE EXISTING WINDOW

COVERINGS

- BASE BID - EXISTING TO REMAIN

- REFER TO INTERIOR FINISH PLANS FOR LOCATIONS

- REFER TO MATERIAL SELECTION SCHEDULE FOR DETAIL

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

E al y E le m en ta ry W h it eh al l D is tr ic t S ch o o ls

E

S o p h ia S t, W h it e h a ll

, M I

PROJECT NO. 25.147

G002

DRAWING INDEX,

GENERAL NOTES, AND

ACCESSIBILITY

10.08.26

SHEET LIST

SHEET # SHEET NAME

GENERAL

G001 COVER SHEET

G002 DRAWING INDEX, GENERAL NOTES, AND ACCESSIBILITY

G101 FIRST FLOOR CODE COMPLIANCE PLANS

DEMOLITION

D101 FIRST FLOOR DEMOLITION PLAN

D101A FIRST FLOOR DEMOLITION PLAN - UNIT A

D101B FIRST FLOOR DEMOLITION PLAN - UNIT B

D101C FIRST FLOOR DEMOLITION PLAN - UNIT C

D101D FIRST FLOOR DEMOLITION PLAN - UNIT D

D102 ROOF DEMOLITION PLAN

D201 FIRST FLOOR CEILING DEMOLITION PLAN

ARCHITECTURAL

A101 FIRST FLOOR PLAN

A101A FIRST FLOOR PLAN - UNIT A

A101B FIRST FLOOR PLAN - UNIT B

A101C FIRST FLOOR PLAN - UNIT C

A101D FIRST FLOOR PLAN - UNIT D

A102 ROOF PLAN

A201 FIRST FLOOR REFLECTED CEILING PLAN

INTERIORS

I101 FIRST FLOOR FINISH PLAN

MECHANICAL DEMOLITION

MD101A MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT A

MD101B MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT B

MD101C MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT C

MD101D MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT D

MD102A MECHANICAL DEMOLITION ROOF PLAN - UNIT A

MD102C MECHANICAL DEMOLITION ROOF PLAN - UNIT C

MECHANICAL

M101A MECHANICAL HVAC FIRST FLOOR PLAN - UNIT A

M101B MECHANICAL HVAC FIRST FLOOR PLAN - UNIT B

M101C MECHANICAL HVAC FIRST FLOOR PLAN - UNIT C

M101D MECHANICAL HVAC FIRST FLOOR PLAN - UNIT D

M102A MECHANICAL HVAC ROOF PLAN - UNIT A

M102B MECHANICAL HVAC ROOF PLAN - UNIT B

M102C MECHANICAL HVAC ROOF PLAN - UNIT C

M102D MECHANICAL HVAC ROOF PLAN - UNIT D

M200 MECHANICAL SCHEDULES

M201 MECHANICAL DETAILS

M202 MECHANICAL NOTES & ABBREVIATIONS

M300 MECHANICAL CONTROLS

M301 MECHANICAL CONTROLS

M302 MECHANICAL CONTROLS

ELECTRICAL DEMOLITION

ED101A ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT A

ED101B ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT B

ED101C ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT C

ED101D ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT D

ED102C ELECTRICAL DEMOLITION ROOF PLAN - UNIT C

ELECTRICAL

E101 ELECTRICAL POWER FIRST FLOOR PLAN - OVERALL

E101A ELECTRICAL POWER FIRST FLOOR PLAN - UNIT A

E101B ELECTRICAL POWER FIRST FLOOR PLAN - UNIT B

E101C ELECTRICAL POWER FIRST FLOOR PLAN - UNIT C

E101D ELECTRICAL POWER FIRST FLOOR PLAN - UNIT D

E102A ELECTRICAL POWER ROOF PLAN - UNIT A

E102C ELECTRICAL POWER ROOF PLAN - UNIT C

E102D ELECTRICAL POWER ROOF PLAN - UNIT D

E201A ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT A

E300 ELECTRICAL NOTES & SYMBOLS

E301 ELECTRICAL ONE-LINE DIAGRAM

E302 ELECTRICAL DETAILS & SCHEDULES

E303 ELECTRICAL PANEL SCHEDULES

TECHNOLOGY

T101 TECHNOLOGY SYMBOL LEGEND

T102A TECHNOLOGY PLAN - UNIT A

T102B TECHNOLOGY PLAN - UNIT B

NOT TO SCALE

DEVICE ALIGNMENT GUIDELINES

SYM DATE ISSUED FOR

A2 11.06.26 BID ADD #02

A2

1. CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE

EXISTING BUILDING PRIOR TO RELATED DEMOLITION

WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY

WALL, FLOOR OR CEILING INCLUDES ALL GENERAL

MECHANICAL AND ELECTRICAL ITEMS WHICH ARE A PART

OF, OR ATTACHED TO IT.

2. CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE

CONDITIONS AND DIMENSIONS AND BE RESPONSIBLE

FOR THE SAME. ADVISE ARCHITECT OF ANY AND ALL

DISCREPANCIES.

3. PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING

CONSTRUCTION AND DEMOLITION AS REQUIRED. FINISH

TO MATCH EXISTING.

4. ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.

5. PROTECT ALL EXISTING FINISHES THROUGHOUT PROJECT.

6. REFER TO DEMOLITION ELEVATIONS, SECTIONS AND

DETAILS FOR ADDITIONAL INFORMATION.

7. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND

ELECTRICAL PLANS FOR ADDITIONAL DEMOLITION NOTES.

8. SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN

NEW CONSTRUCTION, IF REQUIRED.

9. AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED

ITEMS ATTACHED TO THE WALL ARE TO BE REMOVED.

SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,

TACKBOARDS, TACK STRIPS, ETC.

GENERAL DEMOLITION NOTESNO

TE

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

BOYS RR

GIRLS RR

CLASSROOM

CLASSROOM

COMMONS

CLASSROOM

CLASSROOM

CORRIDOR

1 2

1 2

1 2

1 2

1 2

UNIT A

UNIT C

U N

IT

B

U N

IT

C

U N

IT

C

U N

IT

D

U N

IT

C

U N

IT

D

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

E al y E le m en ta ry W h it eh al l D is tr ic t S ch o o ls

E

S o p h ia S t, W h it e h a ll

, M I

PROJECT NO. 25.147

D101C

FIRST FLOOR

DEMOLITION PLAN -

UNIT C

10.08.26

DEMOLITION KEYED NOTES

1 REMOVE EXISTING MECHANICAL EQUIPMENT.

CORDINATE WITH MECHANICAL DRAWINGS. PREP FOR

NEW WORK.

2 REMOVE EXISTING WALL LOUVER. COORDINATE WITH

MECHANICAL. PREP FOR NEW WORK

3 REMOVE EXISTING CABINET HEATER CORDINATE WITH

MECHANICAL. PREP FOR NEW WORK.

4 SALVAGE EXISTING CARPET TILE AROUND MECHANICAL

EQUIPMENT FOR PATCH AND REPAIR

5 REMOVE EXISTING COUNTERTOPS AND PANEL

MOLDING. SALVAGE MOLDING FOR REUSE. CASEWORK

TO REMAIN. PREP FOR NEW SOLID SURFACE

COUNTERTOP MATERIAL.

6 REMOVE EXISTING FLOOR AND WALL BASE.

NO

TE

NR

TH 1/8" = 1'-0"

UNIT C DEMOLITION PLAN

SYM DATE ISSUED FOR

A2 11.06.26 BID ADD #02

UNIT A

UNIT D

U N

IT

A

U N

IT

D

UNIT A

UNIT C

U N

IT

B

U N

IT

C

U N

IT

C

U N

IT

D

U N

IT

C

U N

IT

D

U N

IT

B

U N

IT

A

FLEX

INSTRUCTIONAL

CLASSROOM

FLEX

INSTRUCTIONAL

CLASSROOM

FLEX

INSTRUCTIONAL

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CORRIDOR CORRIDOR COMMONS

CLASSROOM

CLASSROOM

GIRLS RR

BOYS RR

CLASSROOM

CLASSROOM

CLASSROOM

BREAK OUT

CLASSROOM

BREAK OUTRR

CLASSROOMCLASSROOM

CLASSROOMCLASSROOM

CLASSROOM

UPPER MECH

GYM COMMONS

GYM

PERFORMING

ARTS

OFFICE

GIRLS RR

BOYS RR

COPYOFFICE

JCJC

CLASSROOMCLASSROOM

KITCHEN

SERVING

CAFETERIA

ART ROOM

ART ROOMSTAFF LOUNGE

RECEPTION/WAITING

CONF. ROOMMAIL OFFICE

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

STORAGE

OFFICE

CLASSROOM CLASSROOM

BOYS RR

GIRLS RR

OFFICE

MEDIA CENTERLARGE GROUP

INSTRUCTION

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

NOT IN

SCOPE

GYPSUM BOARD

ACP01: 24' x 24' LAY-IN ACOUSTICAL

TILE GRID

1. REFER TO MATERIAL SELECTION SCHEDULE FOR CEILING

SELECTIONS.

2. WHERE CEILING TILE IS LESS THAN 3" AT PERIMETER OF

ROOM PROVIDE A CUT 2x4 TILE IN LIEU OF FULL 2x2 TILE AND SMALL PIECE OF TILE OR DOUBLE GRID - MATCH 2x2

FOR STYLE AND COLOR.

3. AT AREAS OF EXPOSED CEILING PAINT ALL STRUCTURE,

DUCTWORK, PIPING, CONDUIT, HANGERS ETC.,

COORDINATE WITH MECHANICAL, ELECTRICAL AND

PLUMBING SPECIFICATIONS. REFER TO THE REFLECTED

CEILING PLANS FOR PAINT COLORS.

REFLECTED CEILING LEGEND

GENERAL NOTES - REFLECTED CEILINGS

ACP02: 24' x 48' LAY-IN ACOUSTICAL

TILE GRID

1t Y X 1'-0"

CEILING HEIGHT ABOVE

FINISHED FLOOR

CEILING FINISH TYPE

CEILING FINISH INSTANCE

LG

ND

NO

TE

INFILL WITH NEW CEILING TILES AND GRID TO

MATCH EXISTING ADJACENT TILES

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

E al y E le m en ta ry W h it eh al l D is tr ic t S ch o o ls

E

S o p h ia S t, W h it e h a ll

, M I

PROJECT NO. 25.147

A201

FIRST FLOOR

REFLECTED CEILING

PLAN

10.08.26

NR

TH 1/16" = 1'-0"

FIRST FLOOR REFLECTED CEILING PLAN

BULKHEAD TO BE

PAINTED, P03. IN MEDIA

CENTER PAINT BAND TO

CONTINUE AROUND

WALL PERIMETER AT

CEILING REPLACING

"HUNTER GREEN"

SYM DATE ISSUED FOR

A2 11.06.26 BID ADD #02

A2

A2

TYPICAL SYMBOLS & REFERENCESLG

ND

REFERENCE CALLOUT SYMBOL

A101

SIM

DETAIL NUMBER

SHEET NUMBER

EXTERIOR ELEVATION

REFERENCE BUBBLE A101

A ELEVATION LETTER

BUILDING SECTION SYMBOL

A101

SIM

SECTION NUMBER

SHEET NUMBER

INTERIOR ELEVATION

REFERENCE BUBBLE

A101

SHEET NUMBER

A

A

A

A

SIMILAR CONDITION

OPP

OPPOSITE CONDITION

ELEVATION LETTER

SIMILAR CONDITION

OPP

OPPOSITE CONDITION VIEW DIRECTION

1. THE OWNER RESERVES THE RIGHT TO REMOVE ANY ITEM

FROM THE PROJECT PRIOR TO COMMENCEMENT OF

CONTRACTED DEMOLITION WORK.

2. ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED

BEFORE WORK BEGINS.

3. DIMENSIONS GIVEN ARE ACTUAL AND ARE TO THE FACE

OF MASONRY UNITS OR TO THE FACE OF STUD FRAMING

FOR NEW WORK, UNLESS NOTED OTHERWISE. WHERE

APPLICABLE, DIMENSIONS FROM EXISTING CONDITIONS

IS TO THE FACE OF FINISH.

4. DETAILS SHOWN ILLUSTRATE DESIGN INTENT, NOT ALL

POSSIBLE CONDITIONS. FOR CONDITIONS NOT SHOWN,

USE DETAILS CLOSEST TO CONDITION IN QUESTION.

5. DOORS ARE TO BE 4" FROM CORNER OF ROOM, UNLESS

NOTED OR DIMENSIONED OTHERWISE.

6. FIRESTOP ALL INTERCONNECTIONS BETWEEN VERTICAL

AND HORIZONTAL SPACES AND CONCEALED WALL

SPACES AT CEILING, FLOOR AND ROOF LEVELS.

7. FIRESEAL ALL PENETRATIONS, SUCH AS, PIPES, DUCTS,

CONDUITS, ETC. THROUGH FIRE AND/OR SMOKE RATED

ASSEMBLIES.

8. FOR CONTROL JOINT (C.J.) LOCATIONS REFER TO

EXTERIOR ELEVATIONS AND/OR FLOOR PLANS.

9. PAINT ALL ELECTRICAL PANEL COVERS AND ACCESS

PANELS TO MATCH ADJACENT FINISHES. USING OIL-

BASED PAINT, NOT LATEX WALL PAINT.

10. PROVIDE WOOD BLOCKING IN WALLS THAT REQUIRE

WALL MOUNTED EQUIPMENT OR ACCESSORIES.

COORDINATE WITH EQUIPMENT OR ACCESSORY

MANUFACTURER.

11. PROVIDE ALL ASSOCIATED CURBS FOR ROOF TOP

EQUIPMENT AND MECHANICAL ROOF TOP UNITS. LARGE

VOIDS BELOW THE AIR HANDLING UNITS SHALL BE

FILLED WITH INSULATION AS SPECIFIED FOR NOISE

CONTROL.

12. ALL EXISTING ROOF TOP PENETRATIONS BEING

REMOVED REQUIRE ROOF PATCHING TO MATCH

EXISTING ADJACENT.

13. ALL TOILET ROOM ACCESSORIES INCLUDING ALL

REQUIRED GRAB BARS, SOAP DISPENSERS, MIRRORS,

PAPER TOWEL DISPENSERS, SANITARY NAPKIN

DISPOSALS, TOILET PAPER DISPENSERS, AND BABY

CHANGING TABLES ARE TO BE CONTRACTOR FURNISHED

AND CONTRACTOR INSTALLED UNLESS NOTED

OTHERWISE.

GENERAL ARCHITECTURAL NOTESNO

TE

S

NOTE:

MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED

OTHERWISE. SWITCHES (LOCATE ON LATCH SIDE, IF

SWITCH OR DEVICE CANNOT BE

LOCATED ON LATCH SIDE, LOCATE

ONE DOOR LEAF WIDTH AWAY ON

HINGE SIDE) STACK UP TO 2 HIGH

DEVICES TO KEEP WITHIN ADA REACH.

DOOR

LOW

DEVICES

RECEPTACLEVOICE/DATA

MASONRY COURSING

(WHERE APPLICABLE)

F.A. PULL STATION

THERMOSTAT

F.A. AUDIO/VISUAL

ALIGNMENT NOTES

• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.

• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.

• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.

• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT

• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.

F

R O

M F

L O

O R

O R

L A

N D

IN

G

F R

O M

F L

O O

R O

R L

A N

D

IN

G

CARD READER

6' - 0" MIN.

4" MAX

CAMERAS, CLOCKS,

WALL OCCUPANCY

SENSORS

WHITE BOARD (WHERE

APPLICABLE - VERIFY WITH

DETAILS/PLANS PROPER

INSTALL HEIGHT) CENTER ANY

SINGLE DEVICE WITH CENTER

OF WHITE BOARD

ANY DEVICES

SHOWN OVER

DOOR TO BE

CENTERED.

EQ EQ

EQ EQ

F

R O

M F

L O

O R

O R

L A

N D

IN

G

SHORT THROW

PROJECTOR WHERE

APPLICABLE

~12"

MAX TWO DEVICES IN

ONE HIGHER MOUNT

LOCATION, PROVIDE RFI

IF MORE DEVICES ARE

NECESSARY

WHEN DEVICES ARE WITHIN DIMENSION,

STACK HIGH/LOW VERTICALLY AND GROUP

DEVICES AT SAME HEIGHT. UNLESS

DEVICES IS PART OF TECHNOLOGY DETAIL

GROUPING OR SERVING A FURNITURE

GROUP.

CASEWORK, COORDINATE DEVICE

BOTTOM TO BE 2" OVER

BACKSPLASH OR OVER

COUNTERTOP (IF NO BACKSPLASH).

FOR LARGE FORMAT TILE, ALIGN

EDGE OF DEVICE WITH HORIZONTAL

GROUT LINE CLOSEST TO

COUNTERTOP.

COORDINATE OUTLET LOCATIONS

WITH GROUT LINES, EDGE OF

DEVICE ON GROUT LINE IF POSSIBLE.

COORDINATE WITH INTERIOR

DESIGN DRAWINGS.

S

TYPICAL COLUMN

ENCLOSURE, CHASE

OR BUMP-OUT WITH

DEVICES INDICATED

IN PLANS.

EQ EQ

M A

X

4" MAX.

M

IN

PROTRUDING

OBJECTS

REDUCED VERTICAL

CLEARANCE

WATER CLOSET &

LAVATORY CLEARANCE

403.5

CLEAR WIDTH

ACCESSIBLE ROUTE

TRANSFER SHOWER

CLEARANCE

404.2.3.2(A)

FRONT APPROACH PULL SIDE

*IF BOTH CLOSER AND LATCH

ARE PROVIDED

404.2.3.2(B)

FRONT APPROACH PUSH SIDE

*IF BOTH CLOSER AND LATCH

ARE PROVIDED - NEW

BUILDINGS

404.2.3.2(E)

HINGE APPROACH PULL SIDE

404.2.3.2(F)

HINGE APPROACH PUSH SIDE

*48" MIN IF BOTH CLOSER AND

LATCH ARE PROVIDED

404.2.3.2(G)

LATCH APPROACH PULL SIDE

*54" IF CLOSER IS PROVIDED

404.2.3.2(H)

LATCH APPROACH PUSH SIDE

*48" IF CLOSER IS PROVIDED

CHANGES IN LEVEL

NOTE:

INFORMATION SHOWN IS TAKEN FROM THE AMERICAN

NATIONAL STANDARD INSTITUTE (ANSI) AND IS FOR

REFERENCE ONLY AS DESCRIBED IN: ANSI ICC A117.1-2017

M A

X

M

IN

" C L

E A

R

M

IN

CLEAR

60" MIN.

M

IN

MIN.

30"

MIN.

36"

MIN.

32"

M A

X

M

IN

M A

X

S E

T

W

L

L

BACK

WALL

36"

48"

M

IN

MIN.

18" *

M

IN

MIN.

12" *

M

IN

42" MIN.

M

IN

MIN.

22"

M

IN

MIN.

24"

M

IN

MIN.

24"

1/

M A

X

1/

M A

X

1/

M A

X

1/

M A

X

ACCESSIBLE BUILDING CLEARANCESLG

ND

MIN.

15"

MIN.

16"

M

A X

M

IN

8" MIN

6" MIN 11"

MAX

25"

M

IN

KNEE

CLEARANCE

ø

304.3.1.1

NEW BUILDING

TURNING RADIUS

ø

304.3.1.2

EXISTING BUILDING

TURNING RADIUS

ø

OVERLAP AREA

304.3.2

T-SHAPED TURNING RADIUS

NEW BUILDINGS - OPTION 1

68" MIN.

M

IN

16" MIN. 36" MIN. 16" MIN.

M

IN

M

IN

304.3.2

T-SHAPED TURNING RADIUS

NEW BUILDINGS - OPTION 2

64" MIN.

M

IN

11" MIN. 42" MIN. 11" MIN.

M

IN

M

IN

304.3.2

T-SHAPED TURNING RADIUS

NEW BUILDINGS - OPTION 3

64" MIN.

M

IN

12" MIN. 40" MIN. 12" MIN.

M

IN

M

IN

304.3.2.2

T-SHAPED TURNING RADIUS

EXISTING BUILDINGS

60" MIN.

M

IN

12" MIN. 36" MIN. 12" MIN.

M

IN

M

IN

305.3.1

NEW BUILDING

CLEAR FLOOR SPACE

52" MIN.

M

IN

305.3.2

EXISTING BUILDING

CLEAR FLOOR SPACE

48" MIN.

M

IN

404.2.3.2(C)

FRONT APPROACH PUSH SIDE

*IF BOTH CLOSER AND LATCH

ARE PROVIDED - EXISTING

BUILDINGS

M

IN

MIN.

12" *

404.2.3.2(D)

HINGE APPROACH PULL SIDE

M

IN

36" MIN.

LG

ND

ALTERNATES LIST

A1: REFINISH EXISTING DOOR AND FRAMES TO REMAIN

- REFER TO FLOOR PLAN - PLAN NOTE #8

- REFINISH DOOR AND FRAME TO MATCH NEW

A2: REMOVE AND PROVIDE NEW ALUMINUM DOOR,

FRAME, AND HARDWARE - DOOR NUMBER B100-ALT

- REFER TO FLOOR PLAN - PLAN NOTE #9

- DOOR AND FRAME TO MATCH EXISTING BUILDING

STANDARD RED.

- HARDWARE TO MATCH EXISTING BUILDING STANDARD

FOR ENTRY DOORS.

A3: REMOVE AND REPLACE EXISTING WINDOW

COVERINGS

- BASE BID - EXISTING TO REMAIN

- REFER TO INTERIOR FINISH PLANS FOR LOCATIONS

- REFER TO MATERIAL SELECTION SCHEDULE FOR DETAIL

A4: TUNNEL INFILL IN LIEU OF CRACK REPAIR

- BASE BID - CRACK REPAIR AT THE TUNNEL

- ALTERNATE - DEMO EXISTING TUNNEL LID AND

STRUCTURE AND PROVIDE ENGINEER FILL AND NEW SLAB

ON GRADE.

A5: MOSAIC TILE (PT01-A5)

- REFER TO FINISH LEGEND FOR BASE BID AND ALTERNATE

FOR PT01

A2

1. NOT ALL WALL TYPES MAY BE USED ON PROJECT.

2. REFER TO CODE COMPLIANCE PLANS FOR LOCATIONS OF SMOKE AND

FIRE-RATED PARTITIONS.

3. ALL PARTITIONS EXTEND TO BOTTOM OF STRUCTURE / DECK, UNLESS

NOTED OTHERWISE.

4. LINE OF STRUCTURE/DECK AS SHOWN AT THE HEAD CONDITION OF

EACH PARTITION TYPE IS DIAGRAMMATIC ONLY AND DOES NOT

INDICATE EXACT CONSTRUCTION CONDITIONS. TERMINATE RATED

PARTITIONS AT UNDERSIDE OF STRUCTURAL DECK TO MAINTAIN RATING.

PROVIDE APPROPRIATE FRAMING AND GYPSUM BOARD TO OFFSET

AROUND STRUCTURE OR OTHER OBSTRUCTIONS, SUCH AS PIPING OR

DUCTWORK.

5. PARTITIONS MAY TERMINATE AT STRUCTURAL MEMBERS WITH A RATING

GREATER THAN OR EQUAL THE PARTITION, PROVIDED THAT RATING IS

CONTINUOUS TO STRUCTURAL DECK ABOVE.

6. NON-RATED PARTITIONS THAT EXTEND TO STRUCTURE SHALL

TERMINATE AT UNDERSIDE OF STRUCTURAL DECK TO MAINTAIN A

CONTINUOUS PLANE OF GYPSUM BOARD AS A NOISE, SMOKE OR OTHER

TYPE OF BARRIER.

7. ALL PARTITIONS EXTENDING TO STRUCTURE ABOVE SHALL TERMINATE

WITH DEFLECTION TRACK - SEE TYPICAL DETAILS ON THIS SHEET.

8. ALL GYPSUM BOARD PARTITIONS NOT EXTENDING TO THE STRUCTURE

MUST BE BRACED.

9. UL DESIGN NUMBERS REFER TO THE FIRE RESISTANCE DIRECTORY;

UNDERWRITERS LABORATORY, LATEST EDITION.

10. MISCELLANEOUS NON-RATED CHASES TO BE 5/8" GYPSUM BOARD ON 3

5/8" METAL STUD FRAMING AT 16" O.C., UNLESS NOTED OTHERWISE.

11. MISCELLANEOUS FURRING AROUND COLUMNS TO BE 5/8" GYPSUM

BOARD ON 11/2" STUDS, UNLESS NOTED OTHERWISE.

12. FIRE-RATED PARTITIONS TO HAVE FIRE-STOPPING SEALANTS AT HEAD,

SILL JUNCTURE WITH DISSIMILAR MATERIALS, ETC. AND AROUND ALL

PENETRATIONS AND OPENINGS.

13. WITHIN BUILDING INTERIOR PROVIDE BULLNOSE BLOCK IN CMU WALL

ASSEMBLIES AT ALL EXPOSED OUTSIDE CORNERS, INCLUDING WINDOW

AND DOOR JAMBS, UNLESS NOTED OR DETAILED OTHERWISE. PROVIDE

SQUARE OUTSIDE CORNERS AT ALL LOCATIONS FINISHED WITH WALL

TILE, REFER TO FINISH PLANS (I-SHEETS) FOR LOCATIONS.

14. TOOTH-IN MASONRY AT NEW OPENINGS IN EXISTING WALLS.

15. TOOTH-IN NEW MASONRY INFILL INTO EXISTING OPENINGS AT ALL

BULLNOSE BLOCK LOCATIONS.

16. STUD WALLS SPANNING OVER 12'-0" IN HEIGHT SHALL BE A MINIMUM OF

33 MILS THICKNESS.

17. STUD WALL SUPPORTING WALL CABINETS SHALL BE A MINIMUM OF 33

MILS THICKNESS.

GENERAL PARTITION NOTESNO

TE

UNDERSIDE OF

METAL DECK

3" HIGH LEG METAL

TRACK FASTENED

TO SLAB

MINERAL WOOL

INSULATION CUT

TO DECK PROFILE

(AT METAL DECK

LOCATIONS)

5/8" GYPSUM

BOARD (TYPICAL

EACH SIDE)

METAL RUNNER

CHANNEL, SECURE

TO FLOOR

METAL STUDS AT

SPACING INDICATED

CONTINUOUS

ACOUSTIC SEALANT

(EACH SIDE)

CEILING, REFER

TO PLANS

DO NOT SECURE STUDS

AND GYPSUM BOARD TO

HIGH LEG TRACK

SOUND ATTENUATING

INSULATION WHERE

INDICATED

OCCUPIED SPACE

SIDE

UNOCCUPIED SPACE

SIDE

M

IN

UNDERSIDE OF

METAL DECK

3" HIGH LEG METAL

TRACK FASTENED

TO SLAB

MINERAL WOOL

INSULATION CUT

TO DECK PROFILE

(AT METAL DECK

LOCATIONS)

THICK.

WALL

5/8" GYPSUM

BOARD (TYPICAL

EACH SIDE)

METAL RUNNER

CHANNEL, SECURE

TO FLOOR

METAL STUDS AT

SPACING INDICATED

CONTINUOUS

ACOUSTIC SEALANT

(EACH SIDE)

CEILING, REFER

TO PLANS

1"

DO NOT SECURE STUDS

AND GYPSUM BOARD TO

HIGH LEG TRACK

SOUND ATTENUATING

INSULATION WHERE

INDICATED

UNDERSIDE OF

METAL DECK

3" HIGH LEG METAL

TRACK FASTENED

TO SLAB

MINERAL WOOL

INSULATION CUT

TO DECK PROFILE

(AT METAL DECK

LOCATIONS)

THICK.

WALL

5/8" GYPSUM

BOARD

METAL RUNNER

CHANNEL, SECURE

TO FLOOR

METAL STUDS AT

SPACING INDICATED

CONTINUOUS

ACOUSTIC SEALANT

(EACH SIDE)

CEILING, REFER

TO PLANS

1"

DO NOT SECURE STUDS

AND GYPSUM BOARD TO

HIGH LEG TRACK

SOUND ATTENUATING

INSULATION WHERE

INDICATED

ACOUSTICALLY

IMPROVED GYPSUM

BOARD

STC 45 AND 1 HOUR RATED

WHERE INDICATED PER UL V438

• 1/2" MAXIMUM GAP FOR CONTROL JOINT

• 30'-0" MAX. BETWEEN CONTROL JOINTS

• REFER TO PARTITION TYPES FOR COMPLETE

DESCRIPTION OF COMPONENT PARTS

• ALIGN WITH EDGE OF DOOR FRAME AT HEAD

(AS APPLICABLE)

GYPSUM BOARD

METAL STUD

FRAMING

ACOUSTIC

INSULATION

CONTROL JOINT

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

W h it eh al l M id d le S ch o o l

W h it eh al l D is tr ic t

S ch o o ls

S E li z a b e th S t, W h it e h a ll

, M I

PROJECT NO. 25 146

G002

DRAWING INDEX,

PARTITIONS, NOTES,

AND ACCESSIBILITY

10.08.26

SHEET LIST

SHEET # SHEET NAME

GENERAL

G001 COVER SHEET

G002 DRAWING INDEX, PARTITIONS, NOTES, AND ACCESSIBILITY

G101 FIRST FLOOR CODE COMPLIANCE PLANS

SITE

L000 EXISTING SITE CONDITIONS OVERALL

L001 EXISTING SITE CONDITIONS SOUTH COURTYARD OVERALL

L002 EXISTING CONDITIONS NORTHWEST COURTYARD ENLARGEMENT

L003 DEMOLITION PLAN NORTHWEST COURTYARD ENLARGEMENT

L004 SITE PLAN NORTHWEST COURTYARD ENLARGEMENT

L005 PAVEMENT SCORING PLAN NORTHWEST COURTYARD ENLARGEMENT

L006 GRADING AND DRAINAGE PLAN NORTHWEST COURTYARD ENLARGEMENT

L007 LANDSCAPE PLAN NORTHWEST COURTYARD ENLARGEMENT

L008 EXISTING CONDITIONS SOUTHEAST COURTYARD ENLARGEMENT

L009 DEMOLITION PLAN SOUTHEAST COURTYARD ENLARGEMENT

L010 SITE PLAN AND GRADING PLAN SOUTHEAST COURTYARD ENLARGEMENT

L011 LANDSCAPE PLAN SOUTHEAST COURTYARD ENLARGEMENT

L012 EXISTING CONDITIONS NORTH LAWN OVERALL

L013 DEMOLITION PLAN NORTH LAWN COURTYARD ENLARGEMENT

L014 SITE PLAN NORTH LAWN COURTYARD ENLARGEMENT

L015 GRADING AND DRAINAGE PLAN NORTH LAWN COURTYARD ENLARGEMENT

L016 LANDSCAPE PLAN NORTH LAWN COURTYARD ENLARGEMENT

L017 SITE DETAILS

DEMOLITION

D101 FIRST FLOOR DEMOLITION PLAN

D101B FIRST FLOOR DEMOLITION PLAN - UNIT B

D102 ROOF DEMOLITION PLAN

D201 FIRST FLOOR CEILING DEMOLITION PLAN

STRUCTURAL

S001 STRUCTURAL NOTES

S101B FOUNDATION PLAN - UNIT B

S102B ROOF FRAMING PLAN - UNIT B

S201 FOUNDATION DETAILS

S301 FRAMING DETAILS

ARCHITECTURAL

A101 OVERALL FIRST FLOOR PLAN

A101B FIRST FLOOR PLAN - UNIT B

A102 ROOF PLAN

A120 ENLARGED ROOF PLAN

A121 ENLARGED KITCHEN/SERVING PLANS

A122 ENLARGED RESTROOM PLANS

A201 FIRST FLOOR REFLECTED CEILING PLAN

A201B UNIT B REFLECTED CEILING PLAN

A301 BUILDING SECTIONS AND ELEVATIONS

A411 WALL SECTIONS

A421 DETAILS

A601 DOOR SCHEDULES + ELEVATIONS

INTERIORS

I001 MATERIAL SELECTION SCHEDULE

I101 FIRST FLOOR FINISH PLAN

EQUIPMENT

FSE-1 FOOD SERVICE EXISTING CONDITIONS FLOOR PLAN

FSE-2 FOOD SERVICE EQUIPMENT FLOOR PLAN

FSE-3 FOOD SERVICE EQUIPMENT SCHEDULE

FSE-4 FOOD SERVICE ELECTRICAL FLOOR PLAN

FSE-5 FOOD SERVICE ELECTRICAL SCHEDULE

FSE-6 FOOD SERVICE PLUMBING FLOOR PLAN

FSE-7 FOOD SERVICE VENTILATION FLOOR PLAN

FSE-8 FOOD SERVICE EQUIPMENT DETAILS

PLUMBING DEMOLITION

PD101B PLUMBING DEMOLITION FIRST FLOOR PLAN - UNIT B

PD102B PLUMBING DEMOLITION ROOF PLAN - UNIT B

PLUMBING

P001B PLUMBING UNDERFLOOR PLAN - UNIT B

P101B PLUMBING FIRST FLOOR PLAN - UNIT B

P102B PLUMBING ROOF PLAN - UNIT B

P200 PLUMBING SCHEDULE

P201 PLUMBING DETAILS

NOT TO SCALE5

DEVICE ALIGNMENT GUIDELINES

3" = 1'-0"4

TYP GYP BD CONTROL JOINT DETAIL

1 1/2" = 1'-0"2

NON RATED WALL DETAIL

1 1/2" = 1'-0"1

NON RATED WALL (GYP. ONE SIDE) DETAIL

1 1/2" = 1'-0"3

SOUND WALL PARTITION (STC 45)

SHEET # SHEET NAME

MECHANICAL DEMOLITION

MD101A MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT A

MD101B MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT B

MD101C MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT C

MD101D MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT D

MD101E MECHANICAL DEMOLITION FIRST FLOOR PLAN - UNIT E

MD102A MECHANICAL DEMOLITION ROOF PLAN - UNIT A

MD102B MECHANICAL DEMOLITION ROOF PLAN - UNIT B

MD102C MECHANICAL DEMOLITION ROOF PLAN - UNIT C

MD102D MECHANICAL DEMOLITION ROOF PLAN - UNIT D

MECHANICAL

M101A MECHANICAL HVAC FIRST FLOOR PLAN - UNIT A

M101B MECHANICAL HVAC FIRST FLOOR PLAN - UNIT B

M101C MECHANICAL HVAC FIRST FLOOR PLAN - UNIT C

M101D MECHANICAL HVAC FIRST FLOOR PLAN - UNIT D

M101E MECHANICAL HVAC FIRST FLOOR PLAN - UNIT E

M102A MECHANICAL HVAC ROOF PLAN - UNIT A

M102B MECHANICAL HVAC ROOF PLAN - UNIT B

M102C MECHANICAL HVAC ROOF PLAN - UNIT C

M102D MECHANICAL HVAC ROOF PLAN - UNIT D

M102E MECHANICAL HVAC ROOF PLAN - UNIT E

M103 MECHANICAL ENLARGED BOILER PLAN

M200 MECHANICAL SCHEDULES

M201 MECHANICAL DETAILS

M202 MECHANICAL NOTES & ABBREVIATONS

M300 MECHANICAL CONTROLS

M301 MECHANICAL CONTROLS

M302 MECHANICAL CONTROLS

ELECTRICAL DEMOLITION

ED101A ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT A

ED101B ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT B

ED101C ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT C

ED101D ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT D

ED101E ELECTRICAL DEMOLITION FIRST FLOOR PLAN - UNIT E

ED102A ELECTRICAL DEMOLITION ROOF PLAN - UNIT A

ED102B ELECTRICAL DEMOLITION ROOF PLAN - UNIT B

ED102C ELECTRICAL DEMOLITION ROOF PLAN - UNIT C

ED102D ELECTRICAL DEMOLITION ROOF PLAN - UNIT D

ELECTRICAL

E101 ELECTRICAL POWER FIRST FLOOR PLAN - OVERALL

E101A ELECTRICAL POWER FIRST FLOOR PLAN - UNIT A

E101B ELECTRICAL POWER FIRST FLOOR PLAN - UNIT B

E101C ELECTRICAL POWER FIRST FLOOR PLAN - UNIT C

E101D ELECTRICAL POWER FIRST FLOOR PLAN - UNIT D

E101E ELECTRICAL POWER FIRST FLOOR PLAN - UNIT E

E102A ELECTRICAL POWER ROOF PLAN - UNIT A

E102B ELECTRICAL POWER ROOF PLAN - UNIT B

E102C ELECTRICAL POWER ROOF PLAN - UNIT C

E102D ELECTRICAL POWER ROOF PLAN - UNIT D

E102E ELECTRICAL POWER ROOF PLAN - UNIT E

E201B ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT B

E201C ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT C

E201D ELECTRICAL LIGHTING FIRST FLOOR CEILING PLAN - UNIT D

E300 ELECTRICAL SYMBOLS

E301 ELECTRICAL NOTES

E302 ELECTRICAL DEMOLITION ONE-LINE

E303 ELECTRICAL NEW ONE-LINE

E304 ELECTRICAL DETAILS

E305 ELECTRICAL SCHEDULES

E306 ELECTRICAL SCHEDULES

E307 ELECTRICAL PANEL SCHEDULES

E308 ELECTRICAL PANEL SCHEDULES

E309 ELECTRICAL PANEL SCHEDULES - RETROFIT

E401 ELECTRICAL KITCHEN PLANS

TECHNOLOGY DEMOLITION

TD101B TECHNOLOGY DEMO PLAN - UNIT B

TD101D TECHNOLOGY DEMO PLAN - UNIT D

TECHNOLOGY

T101 TECHNOLOGY LINE DIAGRAMS AND SYMBOL LEGEND

T101B TECHNOLOGY PLAN - UNIT B

T101C TECHNOLOGY PLAN - UNIT C

T101D TECHNOLOGY PLAN - UNIT D

MASONRY WALL TYPES

MARK DESCRIPTION

M2.66 6" CMU WITH 7/8" FURRING AND 5/8 GYP BD BOTH SIDES

M4 4" CMU

M8 8" CMU

M10 10" CMU

M12 12" CMU

METAL STUD WALLS

MARK DESCRIPTION

S3A 3 5/8" METAL STUDS WITH 5/8" GYP. BD. BOTH SIDES TO UNDERSIDE OF

DECK ABOVE

S3B 3 5/8" METAL STUD TO UNDERSIDE OF METAL DECK WITH 5/8" GYP. BD.

BOTH SIDES. REFER TO DETAIL FOR WHERE TO STOP GYPSUM BOARD

S3D 3 5/8" METAL STUDS WITH 5/8" GYP. BD. ONE SIDE TO UNDERSIDE OF

DECK ABOVE

S3G 3 5/8" METAL STUDS WITH 5/8" GYP. BD. ONE SIDE TO UNDERSIDE OF

DECK ABOVE

S6A 6" METAL STUDS WITH 5/8" GYP. BD. BOTH SIDES TO UNDERSIDE OF

DECK ABOVE

S6D 6" METAL STUDS WITH 5/8" GYP. BD. ONE SIDE

SYM DATE ISSUED FOR

1. CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE

EXISTING BUILDING PRIOR TO RELATED DEMOLITION

WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY

WALL, FLOOR OR CEILING INCLUDES ALL GENERAL

MECHANICAL AND ELECTRICAL ITEMS WHICH ARE A PART

OF, OR ATTACHED TO IT.

2. CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE

CONDITIONS AND DIMENSIONS AND BE RESPONSIBLE

FOR THE SAME. ADVISE ARCHITECT OF ANY AND ALL

DISCREPANCIES.

3. PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING

CONSTRUCTION AND DEMOLITION AS REQUIRED. FINISH

TO MATCH EXISTING.

4. ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.

5. PROTECT ALL EXISTING FINISHES TO REMAIN

THROUGHOUT PROJECT.

6. REFER TO DEMOLITION ELEVATIONS, SECTIONS AND

DETAILS FOR ADDITIONAL INFORMATION.

7. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND

ELECTRICAL PLANS FOR ADDITIONAL DEMOLITION NOTES.

8. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND

ELECTRICAL PLANS FOR ADDITIONAL INFORMATION ON

SAW CUTTING AREAS

9. SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN

NEW CONSTRUCTION, IF REQUIRED.

10. AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED

ITEMS ATTACHED TO THE WALL ARE TO BE REMOVED.

SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,

TACKBOARDS, TACK STRIPS, ETC.

GENERAL DEMOLITION NOTESNO

TE

1 1

4 4 4 4 4 4 4

1 1

CAFETERIACORR

UNIT B

UNIT C

U N

IT

A

U N

IT

B

W

E X

IS

T

. B R

IC

K

C O

U R

S

IN

G

C O

O R

D

1'

7' - 0"

3' - 0"

2' - 0"

/2

W A

L L

T O

R E

M A

IN

1/

E

X

IS

T

/2

W A

L L

T O

R E

M A

IN

1/

E

X

IS

T

KITCHEN

PASSAGE

STORAGE

EMPLOYEE

LOCKERS

TLT

CORRIDOR

STORAGE

STORAGE

COOLER

STORAGESTORAGE

DN

EXIST. STAIR

TO REMAIN

REFER TO EXTERIOR ELEVATIONS AND DETAILS FOR SELECTIVE DEMO ABOVE WINDOWS

JAN.

OFFICE

NOT IN

SCOPE

REMOVE EXISTING SILL AT WINDOWS TO BE REMOVED

REMOVE EXISTING FLOOR

SLAB COORDINATE W/

NEW WORK

DEMO EXISTING HOOD

SHOWN AS LIGHT

VERTICAL LINE HATCH

PROTECT ALL RACKING TO REMAIN

DEMO EXIST.

LIMESTONE SILL

GRIND CONCRETE FLOOR AROUND

EXPOSED CRACK TO PROVIDE LEVEL

SURFACE FOR NEW FLOORING.

PHOTO OF EXIST. EXTERIOR

WINDOWS

DEMO WINDOW SYSTEMS PER NEW WORK

DEMO E.I.F.S. (APPROX 2'-0") ABOVE WINDOWS

FOR NEW WINDOW AND ENTRY SYSTEMS.

CONDUCT A STRAIGHT DEMO/CUT ACROSS

EXISTING WALL FINISH. PROTECT EXISTING TO

REMAIN ABOVE NEW OPENINGS

DEMO LOUVERS AND INFILL WITH SALVAGED

BRICK

DEMO CAST STONE SILL AND

BRICK WALL BELOW WINDOW

SYSTEMS FOR NEW ENTRY

SYSTEMS

REMOVE EXISTING BRICK

MASONRY TO ACCOMMODATE

NEW WINDOW OPENING.

A2

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

W h it eh al l M id d le S ch o o l

W h it eh al l D is tr ic t

S ch o o ls

S E li z a b e th S t, W h it e h a ll

, M I

PROJECT NO. 25 146

D101B

FIRST FLOOR

DEMOLITION PLAN -

UNIT B

10.08.26

DEMOLITION KEYED NOTES

1 REMOVE EXISTING MECHANICAL EQUIPMENT.

CORDINATE WITH MECHANICAL DRAWINGS. PREP FOR

NEW WORK.

2 REMOVE EXISTING WALL LOUVER. COORDINATE WITH

MECHANICAL DRAWINGS. PREP FOR NEW WORK

3 REMOVE EXISTING WALL AND ANY ITEMS ATTACHED TO

WALL. COORDINATE WITH MECHANICAL, ELECTRICAL,

AND PLUMBING DRAWINGS. ANY DEVICE REMOVAL

SHALL BE COORDINATED WITH OWNER.

4 REMOVE EXISTING STOREFRONT, WINDOW

TREATMENTS, AND ANY ATTACHMENTS.

5 REMOVE EXISTING DOOR AND FRAME.

6 REMOVE EXISTING ELECTRICAL EQUIPMENT.

CORDINATE WITH ELECTRICAL DRAWINGS. PREP FOR

NEW WORK.

7 REMOVE EXISTING FLOORING AND WALL BASE.

8 REMOVE PORTION OF EXISTING WALL. COORDINATE

WITH NEW WORK.

9 REMOVE EXISTING CURB. COORDINATE WITH NEW

WORK.

10 REMOVE EXISTING COUNTERTOPS AND PANEL

MOLDING. SALVAGE MOLDING FOR REUSE. CASEWORK

TO REMAIN. PREP FOR NEW SOLID SURFACE

COUNTERTOP MATERIAL.

11 REMOVE EXISTING WOOD FASCIA AS REQUIRED FOR

NEW METAL FASCIA AND NEW WOOD SUBSTRATE

INSTALL

12 REMOVE EXISTING PLUMBING FIXTURES. COORDINATE

WITH NEW WORK.

13 REMOVE EXISTING SIDEWALK PER LANDSCAPE PLANS

14 REMOVE EXISTING OVERHEAD COILING DOOR &

COUNTER

15 SAW CUT EXISTING CONCRETE FLOOR AS REQUIRED

FOR NEW UTILITY CONNECTIONS. COORDINATE WITH

NEW WORK

16 DEMO TUNNEL IN ITS ENTIRETY IN PREP FOR NEW SLAB

AND FLOOR FINISH

17 CONTRACTOR TO REMOVE, STORE, AND REINSTALL ALL

KITCHEN EQUIP SET TO BE REUSED. COORDINATE W/

OWNER AND NEW WORK

18 REMOVE EXISTING CARPET TILE AND WALL BASE.

CARPET TILE TO BE SAVED FOR RECLAIMATION AND

NOT SENT TO LANDFILL. CARPET TO BE STORED IN

STAGING AREA FOR PICK UP. CONTRCTOR IS

RESPONSIBLE FOR DEMO AND STAGING PER

MANUFACTURER GUIDELINES. COORDINATE WITH

CARPET TILE MANUFACTURER'S RECLAMATION

DEPARTMENT TO SCHEDULE PICKUP LOGISTICS

19 REMOVE EXISTING WOOD SOFFIT AND SUPPORT

FRAMING IN PREP FOR NEW

20 REFER TO ELECTRICAL FOR SCOPE AT ELECTRICAL

BOXES

NO

TE

NR

TH 1/8" = 1'-0"

FIRST FLOOR DEMOLITION PLAN

UNIT B

KEY PLAN

N.T.S.

SYM DATE ISSUED FOR

ROOF 17: SHINGLE ROOF REMOVAL & REPLACEMENT

INSTALL NEW UNDERLAYMENT, ICE AND WATER

SHIELD, AND ARCHITECTURAL ASPHALT SHINGLE ROOF

SYSTEM OVER PREPARED ROOF DECK. PROVIDE NEW

EAVE, RAKE, RIDGE, AND PENETRATION FLASHINGS AS

REQUIRED. REPLACE ALL ROOF VENTING

COMPONENTS, POT VENTS, ETC. INSTALL A COMPLETE

ROOF SYSTEM IN ACCORDANCE WITH PROJECT

SPECIFICATIONS AND MANUFACTURER

REQUIREMENTS. PROVIDE A FULLY WARRANTIED

SYSTEM.

COURTYARD BELOW

A301

A301

A301

A

A301

A301

ROOF 18: REMOVE AND REPLACE

INSTALL NEW ROOF ASSEMBLY INCLUDING CONTINUOUS

INSULATION, ROOF MEMBRANE, FLASHING, AND

ACCESSORIES AS REQUIRED FOR A COMPLETE AND

WARRANTABLE ROOF SYSTEM. ROOF ASSEMBLY SHALL BE

DESIGNED TO MEET APPLICABLE ENERGY CODE AND

DRAINAGE REQUIREMENTS.

VERIFY ROOF DRAIN LOCATIONS , PARAPET HEIGHTS, AND

EDGE METAL COMPATIBILITY WITH FINAL ROOF ASSEMBLY

THICKNESS AND DRAINAGE CONDITIONS. MODIFY OR

EXTEND AS REQUIRED FOR CODE COMPLIANCE AND

MANUFACTURER REQUIREMENTS

NEW METAL FASCIA WRAP OVER EXIST.

WOOD FASCIA. REPLACE ROTTED WOOD

SECTIONS AND REPLACE WITH NEW.

REMOVE AND REINSTALL METAL ROOF

EDGE FOR PROPER LAPPING. TYPICAL AT

(3) SIDES OF MECH. ROOM.

R.D.

A120

Sim

A120

A411

PROVIDE NEW PREFINISHED ALUM GUTTER, COORDINATE DOWNSPOUT LOCATIONS W/ ARCHITECT PRIOR TO INSTALL

R.D.

AHU OR RTU

ROOF DRAIN - TO REMAIN

ROOF TOP UNIT - TO REMAIN

1. ROOF WORK IS LIMITED TO AREAS INDICATED ON THE

DRAWINGS.

2. EXISTING ROOF AREAS NOT INDICATED FOR WORK SHALL

REMAIN. PATCH AND SEAL NEW PENETRATION LOCATIONS

IN EXISTING ROOF AREAS TO REMAIN.

3. TYPICAL ROOF SLOPE 1/4" / 1'-0" UNLESS NOTED

OTHERWISE.

4. PROVIDE ROOFING MANUFACTURER'S STANDARD

ROOFING TERMINATION DETAILS AT ALL PARAPETS, PRE-

MANUFACTURED ROOF EDGE SYSTEMS, CURBS, PIPE

PENETRATIONS, ETC.

5. PROVIDE CRICKETS AS REQUIRED AT MECHANICAL UNITS,

VENTS, AND SIMILAR PROJECTIONS TO PROMOTE POSITIVE

DRAINAGE.

6. ROOF DETAILS SHOWN ARE TYPICAL AND INTENDED TO

ILLUSTRATE GENERAL ROOF ASSEMBLY AND FLASHING

CONDITIONS. FINAL ROOF SYSTEM COMPONENTS AND

CONFIGURATIONS SHALL BE COORDINATED WITH

MANUFACTURER REQUIREMENTS AND FIELD CONDITIONS.

7. PROVIDE ROOF CURBS, FLASHING, AND SUPPORTS AS

REQUIRED FOR ROOFTOP EQUIPMENT AFFECTED BY ROOF

WORK. REFER TO MECHANICAL PLAN FOR LOCATIONS AND

QUANTITIES

8. ALL EXISTING ROOF PENETRATIONS REMOVED AS PART OF

THE WORK SHALL BE PATCHED AND MADE WATERTIGHT

TO MATCH ADJACENT ROOF CONDITIONS.

9. SLOPE AND DRAINAGE PATTERNS SHOWN ARE

DIAGRAMMATIC AND INTENDED TO ILLUSTRATE DESIGN

INTENT. FINAL TAPERED INSULATION LAYOUT SHALL BE BY

ROOFING CONTRACTOR.

10. SHINGLE ROOF SYSTEMS TO BE COMPLETE FULL SYSTEMS

PER MANUFACTURER REQUIREMENTS. REPLACE ALL ROOF

VENTING WITH NEW IN SAME LOCATION. PROVIDE ICE AND

WATER SHIELD, UNDERLAYMENT, ASPHALT SHINGLES

ROOF PLAN LEGEND

ROOF GENERAL NOTES

60 MIL, FULLY ADHERED, SINGLE PLY

ROOF MEMBRANE ON MIN R-30

POLYISOCYANURATE ROOF INSULATION.

INITIAL SRI : 82

EXISTING TO REMAIN, PATCH AND REPAIR

ALL NEW ROOF PENETRATIONS

LG

ND

NO

TE

E.F.

ACCU

EXHAUST FAN / HOOD - TO REMAIN

CONDENSING UNIT - TO REMAIN

M.C. MECHANICAL ROOF CURB - TO REMAIN

R.C. ROUND CURB PENETRATION - TO REMAIN

ROOF SLOPE

ASPHALT SHINGLE ROOF WITH

UNDERLAYMENT AND ICE AND

WATER SHIELD WARRANTY SYSTEM

MEMBRANE CONTINUES INTO ROOF DRAIN

ROOF DRAIN

14 GAGE COATED

STEEL BEARING PAN

FURNISHED WITH

ROOF DRAIN CLAMPING RING FURNISHED WITH ROOF DRAIN

1 1/2" METAL DECK REINFORCED AT

OPENING WITH 3"x3"x1/4" STEEL ANGLES

MEMBRANE ROOFING ON RIGID INSULATION,

TAPER TO DRAIN

/2

CENTER LINE OF VALLEY OF FINISHED ROOF

1" THICK INSULATION

PIPE INSULATION ON

DRAIN LEADERS

ROOF DECK

ROOF INSULATION

FLASHING PER ROOF

MANUFACTURERS

STANDARD DETAILS

VENT PIPE

CONTINOUS SEALANT

SINGLE PLY ROOFING

TREATED NAILERS AS REQUIRED

ROOF DECK

CANT STRIP

11/2" RIGID INSULATION

PREFAB ROOF CURB

COUNTER FLASHING WITH

APPROVED SEALING

WASHER AND FASTENER

@ 6" O.C.

ROOF MOUNTED EQUIPMENT

TREATED 2"x4" NAILER

M

IN

LAP SEALANT

ROOF MEMBRANE

ALUMINUM DRIP EDGE TO MATCH EXISTING PROFILE

RIGID POLYISO INSULATION (BASE &

TAPERED) OVER EXISTING ROOF DECK.

ROOF MEMBRANE

EXTEND MEMBRANE PER MFR. REQUIREMENTS

NEW 1/2" COVER BOARD (HIGH DENSITY

RIGID INSUL.) OVER TAPERED INSULATION

EXISTING WALL

11"

EXISTING ROOF DECK

EXISTING ROOF,

FIELD VERIFY

DUCT ROUTING

THROUGH EXISTING

WALL, PROVIDE A

WATER TIGHT

PENETRATION

NEW CMU WALL

FOR RESTROOMS

B

A ELEVATION B SECTION C PLAN

2 1/2"x1/2" FLAT

STOCK

GALVANIZED

3/4" -

GALVANIZED

RUNGS

1' - 6"

7"

1'

BOTTOM

OF ROOF

DECK

2 1/2"x1/2"

FLAT STOCK

GALVANIZE

D

ANCHOR TO

WALL

@ 3'-0" O.C.

VERTICAL

MAXIMUM3/4" -

GALVANIZED

RUNGS

FLOOR/RO

OF

LADDER SAFETY SYSTEM

(LADDERS ABOVE 24FT):

PROVIDE A COMPLETE SYSTEM

INCLUDING AUTOMATIC

PERSONAL FALL ARRESTOR

CABLE SLEEVES, INTEGRAL

SWIVEL, CARABINEERS, BOTTOM

BRACKET WITH DUAL FUNCTION

TENSIONER, TOP BRACKET WITH

SHOCK ABSORBER, 3/8"

STAINLESS STEEL CABLE AND

CABLE TERMINATION KIT.

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

W h it eh al l M id d le S ch o o l

W h it eh al l D is tr ic t

S ch o o ls

S E li za b e th S t, W h it e h a ll

, M I

PROJECT NO. 25 146

A120

ENLARGED ROOF PLAN

10.08.26

NR

TH 1/8" = 1'-0"1

ENLARGED ROOF GYM

NR

TH 1/8" = 1'-0"2

ENLARGED ROOF MECHANICAL

1 1/2" = 1'-0"3

TYPICAL ROOF DRAIN DETAIL

1 1/2" = 1'-0"8

TYPICAL ROOF PENETRATION DETAIL

1 1/2" = 1'-0"5

TYPICAL ROOF CURB DETAIL

1 1/2" = 1'-0"4

PARAPET CAP MEMBRANE DETAIL1

1/4" = 1'-0"7

ROOF LADDER DETAIL W/ SIDE RAIL EXTENSION

1/4" = 1'-0"6

ROOF SECTION DETAIL DUCT/AIR HANDLER

SYM DATE ISSUED FOR

5/8" GYP. BD. - PAINT

3-5/8" CFMF AT 16" O.C.

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

S.S FLASHING W/ HEMMED

EDGE (YORK 304 SA)

SELF-ADHERED THROUGH

WALL FLASHING

SHIM, SEALANT AND

BACKER ROD AROUND

PERIMETER, BOTH SIDES

EXIST. WALL, F.V.

EXIST. BEAM BOX-OUT,

REMOVE EXIST. WD

FINISH AND WRAP W/

DRYWALL, PAINT

FIRST FLOOR

F.F. : 100' - 0" 1

EXIST. CONC. FOUNDATION,

F.V.

EXIST. CMU, F.V.

EXIST. SLOPE GRADE AWAY

FROM BLD - SEE SITE, F.V.

CAST STONE W/ SLOPED

TOP AT SILL, COLOR TO

MATCH EXIST.

WEEP VENTS AT 32" O.C. AT

TOP OF OPENING

INFILL CAVITY W/ RIGID

INSULATION

SELF-ADHERED THROUGH

WALL FLASHING

S.S FLASHING W/ HEMMED

EDGE (YORK 304 SA)

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

WINDOW SILL - SEE FINISH

PLANS

CAFETERIA

B104

FLUID APPLIED AIR/VAPOR

BARRIER

F.T. 1X WOOD BLOCKING 7

/8

3 5/8"PREFIN. ALUM. SILL

FLASHING

EXISTING EIFS SYSTEM, SEE

EXTERIOR ELEV. FOR NEW

WORK

5/8" GYP. BD. - PAINT

3-5/8" CFMF AT 16" O.C.

SHIM, SEALANT AND

BACKER ROD AROUND

PERIMETER, BOTH SIDES

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

ALUM DOOR AND FRAME -

SEE DOOR SCHED.

PATCH AND REPAIR AS

REQUIRED PRIOR TO PAINT

EXIST. WALL, F.V.

SELF-ADHERED THROUGH

WALL FLASHING

S.S FLASHING W/ HEMMED

EDGE (YORK 304 SA)

FIRST FLOOR

F.F. : 100' - 0" 1

1" IGU

ALUM DOOR AND FRAME -

SEE DOOR SCHED.

THRESHOLD SET IN MASTIC

FOR WATERTIGHT SEAL

EXIST. CONC. FOUNDATION,

F.V.

DOWEL NEW SLAB TO

EXIST. FOUNDATION TO

PREVENT HEAVING

SITE CONCRETE, SLOPE

AWAY FROM BLD. - SEE

SITE

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

PREFIN. ALUM. SILL

FLASHING

WINDOW SILL - SEE FINISH

PLANS

EXIST. MASONRY WALL, F.V.

EXIST. CAST STONE SILL, F.V.

FLUID APPLIED AIR/VAPOR

BARRIER

SHIM, SEALANT AND

BACKER ROD AROUND

PERIMETER, BOTH SIDES

CAFETERIA

B104

ALUM DOOR AND FRAME -

SEE DOOR SCHED.

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

SELF-ADHERED THROUGH

WALL FLASHING

SHIM, SEALANT AND

BACKER ROD AROUND

PERIMETER, BOTH SIDES

EXIST. MASONRY WALL, F.V.

WEEP VENTS AT 32" O.C. AT TOP OF WALL

FACE BRICK, MATCH EXIST.

3" RIGID INSULATION - R11.4 MIN.

FLUID APPLIED AIR/VAPOR BARRIER

8" CMU

EXISTING STEEL - F.V.

SINGLE PLY ROOF

MEMBRANE ON 1/2" GYP

SHEATHING COVER BD

OVER POLYISO ROOF

INSULATION ON AIR/VAPOR

BARRIER OVER 1/2" GYP

SHEATHING

EXISTING ROOF DECK - F.V.

CONDITION

PREFIN. ALUM. PLANK SOFFIT OVER AIR

BARRIER AND 5/8" PLYWD SHEATHING,

PROVIDE VENTING AT EACH END

THERMALLY BROKEN ADJUSTABLE

MASONRY ANCHOR 16" O.C. VERT. AND

16" O.C. HORIZ.

3-5/8" CFMF AT 16" O.C.

PREFIN METAL ROOF

EDGE, COLOR TO MATCH

EXIST.

F U

L L

I N

S U

L . C

O V

E R

A G

E

1'

PREFIN. ALUM. FASCIA -

.040" THICKNESS MIN.,

COLOR TO MATCH EXIST.

FLUID APPLIED AIR/VAPOR

BARRIER

F.T. 3/4" PLYWOOD SHEATHING

LAP ROOF MEMBANE OVER

ROOF EDGE, UNDER CAP

MECH.

B103

WALL-WASH LIGHT

FIXTURE - SEE ELECTRICAL

MECH.

B103

FACE BRICK, MATCH EXIST.

3" RIGID INSULATION - R11.4

MIN.

FLUID APPLIED AIR/VAPOR

BARRIER

CAVITY FILTER DRAINAGE

MESH

WEEP VENTS AT 32" O.C. AT

TOP OF OPENING

REMOVE AND REWORK

GRADE AS REQUIRED FOR

NEW BRICK INSTALL.

VERIFY GRADE WILL

COVER FIRST COURSE OF

BRICK AS SHOWN AND

WILL SLOPE AWAY FROM

BLD.

STEEL ANGLE FOR

MASONRY SUPPORT - SEE

STRUCT.

EXIST. CONC. FOUNDATION,

F.V.

S.S FLASHING W/ HEMMED

EDGE (YORK 304 SA)

FLEXIBLE THROUGH WALL

FLASHING

8" CMU

W/ EXIST. CONDITIONS

1' - 4" +/- COORD.

1"

M

IN

C O

V E

R A

G E

REMOVE EXISTING

LIMESTONE SILL

AND INFILL W/

CONC OR CMU.

SECURE TO EXIST.

CONC.

MECH.

B103

W

E X

IS

T

. C O

N D

IT

IO

N S

1'

C O

O R

D

FACE BRICK, MATCH EXIST.

3" RIGID INSULATION - R11.4

MIN.

FLUID APPLIED AIR/VAPOR

BARRIER

8" CMU

SELF-ADHERED THROUGH

WALL FLASHING

EXIST. MASONRY WALL, F.V.

FIRST FLOOR

F.F. : 100' - 0"1

CAVITY FILTER DRAINAGE

MESH

WEEP VENTS AT 32" O.C. AT

TOP OF OPENING

SELF-ADHERED THROUGH

WALL FLASHING

S.S FLASHING W/ HEMMED

EDGE (YORK 304 SA)

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

5 1/2"

DISH WASHING

B106

EXIST. CONC. FOUNDATION,

F.V.

FILL COLLAR JOINT W/

MORTAR

3" RIGID INSULATION - R11.4

MIN.

FLUID APPLIED AIR/VAPOR

BARRIER

FACE BRICK, MATCH EXIST.

WEEP VENTS AT 32" O.C. AT

TOP OF OPENING

CAST STONE W/ SLOPED

TOP AT SILL, COLOR TO

MATCH EXIST.

S.S FLASHING W/ HEMMED

EDGE (YORK 304 SA)

SELF-ADHERED THROUGH

WALL FLASHING

8" CMU

WINDOW SILL - SEE FINISH

PLANS

SHIM, SEALANT AND

BACKER ROD AROUND

PERIMETER, BOTH SIDES

THERMALLY BROKEN

ADJUSTABLE MASONRY

ANCHOR 16" O.C. VERT. AND

16" O.C. HORIZ.

1' - 4"

F.T. 2X4 WOOD BLOCKING

ALIGN W/ EXIST.

CMU WALL

DAMPPROOFING AT NEW

FOUNDATIONS

PREFIN. ALUM. SILL

FLASHING

S.S FLASHING W/ HEMMED

EDGE (YORK 304 SA)

DISH WASHING

B106

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

SUSPENDED ACOUSTIC

GRID CEILING SYSTEM - SEE

CLG PLANS

EXISTING EIFS SYSTEM, SEE

EXTERIOR ELEV. FOR NEW

WORK

SEALANT AND BACKER

ROD

T Y

P

1"

/8

9 1/2"

1/

/4

F.T. 2X4 WOOD BLOCKING

F.T. 1X WOOD BLOCKING

5/8" GYP. BD. - PAINT

6" CFMF AT 16" O.C.

SUSPENDED ACOUSTIC

GRID CEILING SYSTEM - SEE

CLG PLANS

INTERIOR SUSPENDED

BACKLIT SIGNAGE - SEE

CLG PLANS

SUSPENDED ACOUSTIC

BAFFLE PLANK SYSTEM -

SEE CLG PLANS

STRIP LIGHT FIXTURE - SEE

ELECTRICAL

5/8" GYP. BD. - PAINT

WOMENS

B102

CORR

B100

DOOR AND FRAME - SEE

DOOR SCHED.

8" CMU - BULLNOSE

EXIST. MASONRY WALL, F.V.

SEE FLOOR PLAN FOR

ADDITIONAL NOTES

SEALANT AND BACKER

ROD

6" +/- 6" +/-

5/8" GYP. BD. W/ METAL

WRAP - SEE FINISH PLANS

EXISTING STEEL - F.V.

3-5/8" CFMF - INSTALL

TIGHT TO COL.

5/8" GYP. BD. W/ METAL

WRAP - SEE FINISH PLANS

3-5/8" CFMF - INSTALL

TIGHT TO COL.

EXISTING STEEL - F.V.

6" +/- 6" +/-

BOOTH BELOW -

SEE FINISH PLANS

ALUM STOREFRONT

SYSTEM - SEE FRAME ELEV.

EXIST. CMU LEDGE AND

NEW SILL BELOW

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

W h it eh al l M id d le S ch o o l

W h it eh al l D is tr ic t

S ch o o ls

S E li z a b e th S t, W h it e h a ll

, M I

PROJECT NO. 25 146

A421

DETAILS

10.08.26

1 1/2" = 1'-0"10

NORTH WALL TOP OF WALL

1 1/2" = 1'-0"6

NORTH WALL BASE OF WALL

1 1/2" = 1'-0"9

ALUM DOOR HEAD DETAIL

1 1/2" = 1'-0"1

ALUM THRESHOLD DETAIL

1 1/2" = 1'-0"2

SOUTH WALL STOREFRONT SILL DETAIL

1 1/2" = 1'-0"5

PLAN DETAIL AT ALUM JAMB

1 1/2" = 1'-0"11

TOP OF WEST MECHANICAL WALL

1 1/2" = 1'-0"3

BASE OF WEST MECHANICAL WALL

1 1/2" = 1'-0"7

PLAN DETAIL AT WEST MECHANICAL WALL

1 1/2" = 1'-0"4

NORTH WALL INFILL BASE OF WALL

1 1/2" = 1'-0"8

NORTH WALL INFILL TOP OF WALL

1 1/2" = 1'-0"12

CAFETERIA CLG DETAIL

1 1/2" = 1'-0"13

DETAIL AT MASONRY OPENING

1 1/2" = 1'-0"14

SOUTH COL WRAP

1 1/2" = 1'-0"15

NORTH COL WRAP

SYM DATE ISSUED FOR

A2 11.06.26 BID ADD #02

A2

1. REFER TO SHEET I001 FOR ADDITIONAL INFORMATION ON

INTERIOR MATERIALS.

2. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH AND

HEIGHTS.

3. REFER TO DOOR SCHEDULE FOR FINISH ON DOORS AND FRAMES.

4. FINISH TAGS APPLY TO LIKE MATERIALS IN ENTIRE ROOM. I.E.

CASEWORK TAG MAY ONLY CALLOUT ONE RUN OF CASEWORK,

BUT ALL CASEWORK IN ROOM RECEIVE THE SAME FINISHES,

UNLESS TAGGED DIFFERENTLY.

5. CASEWORK FINISH TAGS DO NOT APPLY TO CUSTOM MILLWORK

PIECES. REFER TO ENLARGED MILLWORK DETAILS FOR FINISH

MATERIALS.

6. WALL MOUNTED DIFFUSERS, GRILLES, ACCESS PANELS,

ELECTRICAL PANELS, ETC. ARE TO BE PAINTED WITH AN OIL-BASED

PAINT TO MATCH THE ADJACENT WALL FINISH.

7. CEILING ACCESS PANELS ARE TO BE PAINTED TO MATCH

ADJACENT CEILING FINISH.

8. ALL DRYWALL OUTSIDE CORNERS TO RECEIVE CORNER GUARDS

(CG01). INSTALL BOTTOM EDGE OF CORNER GUARD AT TOP OF

WALL BASE, UNLESS OTHERWISE NOTED.

9. ALL FLOORING TRANSITIONS TO OCCUR CENTERED UNDERNEATH

FLOOR LEAF.

10. WINDOW TREATMENTS TO BE REPLACED IN CLASSROOMS ONLY.

ALL OTHER AREAS EXISTING TO REMAIN.

11. REFER TO SHEET I001 FOR MATERIAL TRANSITIONS.

12. REFER TO SPECIFICATION FOR MORE INFORMATION.

13. REFER TO FLOOR PLANS, EXTERIOR ELEVATIONS AND FRAME

TYPES FOR HEIGHT AND WIDTH OF OPENINGS.

14. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION

GENERAL NOTES - INTERIORSNO

TE

GENERAL CASEWORK/MILLWORK NOTESNO

TE

1. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION.

2. FILLER PANELS SHALL BE NO LESS THAN 2" WIDE, UNLESS NOTED

OTHERWISE.

3. REFER TO FLOOR FINISH PLANS FOR CASEWORK AND

COUNTERTOP FINISHES BY ROOM.

4. FINISH ANY EXPOSED END PANELS, UNDERSIDE OF CABINETS OR

OPEN CABINETS, WITH PLASTIC LAMINATE SPECIFIED FOR FRONTS

IN THAT ROOM.

5. ALL VERTICAL AND HORIZONTAL EXPOSED AND SEMI-EXPOSED

SURFACES TO BE FINISHED WITH BODY PLASTIC LAMINATE.

6. PATTERN OR GRAIN DIRECTION TO BE VERTICAL ON DOORS AND

HORIZONTAL ON DRAWERS - PER AWI STANDARDS, UNLESS NOTED

OTHERWISE.

7. 3MM EDGE BANDING TO MATCH LAMINATE SELECTION. SQUARE

EDGE.

1. PROVIDE SOFT JOINT WHERE TILE MEETS CEILING/ DOOR FRAMES.

2. PROVIDE DILEX COVE TRIM AT BASE OF TILED WALLS.

3. REFER TO MATERIAL TRANSITION DETAILS ON SHEET 1001 FOR

MORE INFORMATION AND LOCATIONS NECESSARY.

4. REFER TO MATERIAL SELECTION SCHEDULE FOR GROUT

SELECTIONS AND JOINT WIDTHS (ACCORDING TO TILE SELECTION)

TILE GENERAL NOTESNO

TE

± 1/8" THICK SHEET VINYL OR RUBBER TILE

CARPET TILE

JOHNSONITE SLIMLINE TRANSITION,

FINISH:_______

PORCELAIN TILE TO CARPET TILE (PT - CPT)

PORCELAIN TILE

THINSET OR MORTAR

SCHLUTER RENO-TK - FINISH:_______

PORCELAIN TILE TO SEALED OR POLISHED

CONCRETE (PT - SC - PC)

PORCELAIN TILE

THINSET OR

MORTAR

SCHLUTER RENO-U - FINISH:_______

SEALED OR POLISHED

CONCRETE

PORCELAIN TILE TO SHEET VINYL (PT - SV)

PORCELAIN TILE

THINSET OR MORTAR

SCHLUTER RENO-U - FINISH:_______

± 1/8" THICK SHEET VINYL OR RUBBER TILE

PORCELAIN TILE TO SHEET VINYL (PT - SV)

PORCELAIN TILE

THINSET OR MORTAR

SCHLUTER RENO-V - FINISH:_______

± 1/4" THICK SHEET VINYL

PORCELAIN TILE TO RUBBER TILE (PT - RBT)

CARPET TILE TO SHEET VINYL (CPT - SV)

CARPET TILE TO RUBBER TILE (CPT - RBT)

SCHLUTER QUADEC - TRENDLINE

COLOR:_______, GROUT FILL VOID

WING WALL OR

OUTSIDE

CORNER

THINSET OR MORTAR

PORCELAIN OR

CERAMIC TILE, TYP.

SCHLUTER DILEX-BWA

"SOFT JOINT"; FINISH:_______

THINSET OR MORTAR

PORCELAIN OR

CERAMIC TILE, TYP.

CEILING, DOOR FRAME, OR

OTHER FIXED BUILDING

ELEMENT

WALL TILE OUTSIDE

CORNER

WALL TILE SOFT

JOINT

PORCELAIN TILE WALL BASE (PTB) AT PAINTED

WALLS

CUT PORCELAIN TILE

BASE

SCHLUTER DILEX-AHK - FINISH:_______

PORCELAIN FLOOR TILE -

REFER TO SPECIFICATIONS

SCHLUTER QUADEC - COLOR:_______

GROUT FILL VOID

PAINTED GYPSUM BOARD WALL PER

FINISH PLAN

SCHLUTER DILEX-BWA

"SOFT JOINT"; FINISH:_______

THINSET OR MORTAR

PORCELAIN OR

CERAMIC TILE, TYP.

COLUMN OR OTHER FIXED

BUILDING ELEMENT

FLOOR TILE SOFT

JOINT

TILED WALLS WITHOUT TILE

BASE

FLOOR FINISH OTHER

THAN TILE

CERAMIC OR PORCELAIN

WALL TILE (INCLUDING

MOSAICS)

SCHLUTER DILEX-AHK - FINISH:_______

SHEET NUMBER

SHEET NAME

REVISIONS

ISSUE DATE

©2026

SHEET SIZE

30 x 42

W h it eh al l M id d le S ch o o l

W h it eh al l D is tr ic t

S ch o o ls

S E li za b e th S t, W h it e h a ll

, M I

PROJECT NO. 25 146

I001

MATERIAL SELECTION

SCHEDULE

10.08.26

MATERIAL SELECTION SCHEDULE

ABBREV ITEM MANUFACTURER PATTERN COLOR PRODUCT NO. SIZE REMARKS PRODUCT REP.

ACB01 ACOUSTIC CEILING BAFFLES MDC ZINTRA STICKS BUNDLES - WIDE WHITE OAK ZTR4911PW1S 37.5” W X 108”

H X 2.4” D

SUSPENSION INSTALL, 8'8" AFF

ACP01 ACOUSTIC CEILING PANEL ARMSTRONG CORTEGA ANGLED TEGULAR EDGE WHITE 704A 24" x 24" BUILDING STANDARD, 15/16" GRID

ACP02 ACOUSTIC CEILING PANEL USG CEILINGS RADAR SQUARE EDGE WHITE 2410 24" X 48" BUILDING STANDARD

ACP03 ACOUSTIC CEILING PANEL ARMSTRONG KITCHEN ZONE WITH 15/16" GRID WHITE 673 24" X 24"

AL01 ANODIZED ALUMINUM

STOREFRONTS

DARK BRONZE VERIFY EXISTING CONDITIONS AND MATCH ADJACENT FINISH

AL01 ALT ANODIZED ALUMINUM

STOREFRONTS

BLACK VERIFY EXISTING CONDITIONS AND MATCH ADJACENT FINISH

CG01 CORNER GUARDS INPRO CORNER GUARDS TAPE ON CORNER GUARDS (WITHOUT TAPE) 90

DEGREE

BRUSHED SILVER 11248E-5E025 1-1/2" X 48" INSTALL WITH HEAVY-DUTY ADHESIVE AT ALL OUTSIDE GYP.

CORNE…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .