Bipolar Ionization
Cancelled State & local contract opportunity Posted
- Solicitation number
- CCGA-2227
- State
- Georgia
- Responses due
Opportunity facts
- Jurisdictions
- NIGP codes
- 03102 Air Conditioning Units, Portable (For Computer Rooms, Hospital Rooms, Sporting Events, Etc.)
- 03103 Air Conditioners: Commercial, And Parts And Accessories Not Individually Itemized
- 03104 Air Conditioners: Controlled Environment (For Computer Rooms, Etc.), And Parts And Accessories Not Individually Itemized)
- 03105 Air Conditioners (Cooling And Cooling/Heating Types): Window And Wall Mounted, And Parts And Accessories Not Individually Itemized
- 03129 Dampers, Motorized
- UNSPSC codes
- 40101724 Adsorption chiller
- 40101701 Air conditioners
- 40101706 Air conditioner shutters
- 52141510 Domestic portable air conditioners
- 40101700 Cooling equipment and parts and accessories
- 40101702 Cooling exchangers
- 40101718 Cooling coil
- 40101721 Water cooled condensor
- 40101720 Unit cooler
- 40101723 Thermoelectric cooler
- Point of contact
-
- Paul Melchor pmelchor@ccga.edu (912) 279-5833
Opportunity details come from ssl.doas.state.ga.us. Updated .
About this opportunity
College of Coastal Georgia is requesting bids for installation of Needlepoint BiPolar Ionization (NBPI) units on existing central station air handlers across multiple buildings on its Main Campus in Brunswick and Camden Center in Kingsland, with bids due July 14, 2022. Work includes electrical support for HVAC demolition and new system installation, with buildings remaining occupied during construction and work restricted to 10 PM–7 AM or weekends to minimize disruption to classroom operations.
The contractor must hold a current Georgia mechanical license, demonstrate four years in business without prior default, and provide evidence of successful completion of at least three mechanical construction projects involving hydronic systems and air distribution totaling a minimum $275,000 each. A superintendent with four years of similar project experience is required. A mandatory preconstruction meeting follows Notice of Award.
NBPI systems must meet specific pathogen kill-rate criteria: MRSA >96% in 30 minutes, E. coli >99% in 15 minutes, TB >69% in 60 minutes, and C. difficile >86% in 30 minutes, with independent NELEC-accredited laboratory verification. Systems must produce a minimum of 15 million ions per cubic centimeter, operate with balanced positive and negative ion output, comply with UL 867-2007 standards, and generate zero detectable ozone. The contractor must maintain relative humidity below 55 percent and implement weekly construction filter changes for dust control.
Two deductive alternates are available: Alternate No. 1 to omit electric unit heaters and associated electrical infrastructure, and Alternate No. 2 to omit unit-mounted variable frequency controllers and relocate existing controllers. The contractor provides a one-year warranty from Material Completion and must submit product specifications, shop drawings, test reports, and operation and maintenance manuals before project closeout. Progress meetings are scheduled at maximum bi-monthly intervals. Questions due and anticipated award date are not identified in the source.
Opportunity text
DESCRIPTION OF ALTERATIONS WORK A. Scope of alterations work is indicated on drawings. B. Install Needlepoint BiPolar Ionization (NBPI) units on existing central station air handlers in multiple buildings on the Main Campus and in the Camden Center. C. Perform electrical work in support of demolition of existing HVAC and installation of new HVAC systems. D. The buildings shall be OCCUPIED by the Owner during the construction. E. Protect existing floors, finishes and buildings during the HVAC upgrades. F. Make other improvements as noted on the Drawings.
Files
On GovTribe
Work this opportunity
- Track it in your pipeline