Request for Information - Remove and Replace CRAC Units and Chillers
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- F2M3CB6043A003
- Agency
-
Air Education and Training Command
Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- 4120 Air Conditioning Equipment
- Place of performance
- Jbsa Ft Sam Houston, Texas 78234, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Education and Training Command is soliciting sources to remove and replace Computer Room Air Conditioning (CRAC) units and chillers at Building 2265, Fort Sam Houston, Texas, with responses due by August 7, 2026 at 1000 hours CDT. This is a pre-solicitation market survey (Sources Sought) targeting small businesses under NAICS 238220 with a $19 million size standard.
Place of performance is Building 2265, JBSA Fort Sam Houston, located at 2406 Gun Shed Road, Texas 78234. The work includes disconnection, removal, and disposal of existing equipment, followed by installation, connection, and commissioning of new units. The contractor must be a licensed HVAC and electrical contractor with demonstrated experience in critical data center environments. All personnel requiring access to secure areas must obtain clearance within 45 days.
The scope requires replacement of six "same-in-kind" Data Aire CRAC units (two 45-ton, two 40-ton, and two 25-ton) and two "same-in-kind" Daikin chillers (115-ton each). CRAC units must feature direct-drive electronically commutated fans with minimum 0.75 inches water gauge external static pressure and MERV 8 minimum filtration. Chillers must provide minimum 75-ton capacity at 110F design ambient with minimum 15.3 EER part-load efficiency and low-ambient operation capability to -20F. All equipment operates on 460V AC, 3-phase, 60 Hz power. Both chillers and CRAC units require BACnet MS/TP or BACnet/IP integration with building automation networks.
Work must maintain continuous cooling with zero downtime; any required outage requires at least 60 days' notice. Performance period is estimated at 60 calendar days. Work occurs Monday through Friday, 7:00 a.m. to 5:00 p.m., with 48-hour coordination notice required. Deliverables include commissioning reports, two complete Operation and Maintenance manual sets, as-built drawings, and minimum four hours of on-site training for facility personnel.
Interested firms must submit a completed RFI questionnaire, five-page capability statement, and any questions by August 7, 2026 to SrA Jamie Cutright (Contract Specialist) and Charles Woyome (Contracting Officer). The Government anticipates a Firm Fixed Price award. SAM Amendment 00001 replaced the RFI Word document with an editable PDF file.
Notice text
2 versions
Update #2 · Latest ·
SAM Amendment 00001:
1, Replaced the RFI Microsoft Word document file with an editable PDF files due to the inablity to edit the Word document.
------------------------------------------------------------------------------------------------------------------------------------------
THIS IS NOT A REQUEST FOR QUOTE: The purpose of this Sources Sought Notice is to query the market for potential interested, capable, responsible, and qualified small businesses that can provide and perform the stated requirement IAW the attached DRAFT Statement of Work. The Government is interested in collecting market information in accordance with (IAW) RFO Part 10. If interested, please review all attachments and fill out and return a copy of the attached Request For Information (RFI) document along with your capabilities.
Please note that this is not a construction requirement.
Please return the filled out RFI and capability statement to the POCs in this notice.
Description of Services: The contractor shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary to remove and replace the Computer Room Air Conditioning (CRAC) Units and Chillers in Building 2265 at Fort Sam Houston. This is a life-cycle replacement of an HVAC system with incidental services requested by the 502d Civil Engineer Squadron (502CES) FSH office, which includes the disconnection, removal and disposal of the old units, followed by this installation, connection, and commissioning of the new equipment. The work will be conducted at Building 2265, JBSA FSH 78234. The objective is for the removal and replacement of six (6) “same-in-kind” Data Aire complete and fully operational CRAC units, and two (2) “same-in-kind” Daikin complete and fully operational Chillers, in accordance with (IAW) all applicable codes, standards, and manufacturer specifications.
Attachments:
1. Request for Information_CRAC Units and Chillers (fill out)
2. DRAFT Statement of Work
3. DRAFT Salient Characteristics
Update #1 ·
THIS IS NOT A REQUEST FOR QUOTE: The purpose of this Sources Sought Notice is to query the market for potential interested, capable, responsible, and qualified small businesses that can provide and perform the stated requirement IAW the attached DRAFT Statement of Work. The Government is interested in collecting market information in accordance with (IAW) RFO Part 10. If interested, please review all attachments and fill out and return a copy of the attached Request For Information (RFI) document along with your capabilities.
Please note that this is not a construction requirement.
Please return the filled out RFI and capability statement to the POCs in this notice.
Description of Services: The contractor shall provide all personnel, equipment, tools, materials, supervision, and quality control necessary to remove and replace the Computer Room Air Conditioning (CRAC) Units and Chillers in Building 2265 at Fort Sam Houston. This is a life-cycle replacement of an HVAC system with incidental services requested by the 502d Civil Engineer Squadron (502CES) FSH office, which includes the disconnection, removal and disposal of the old units, followed by this installation, connection, and commissioning of the new equipment. The work will be conducted at Building 2265, JBSA FSH 78234. The objective is for the removal and replacement of six (6) “same-in-kind” Data Aire complete and fully operational CRAC units, and two (2) “same-in-kind” Daikin complete and fully operational Chillers, in accordance with (IAW) all applicable codes, standards, and manufacturer specifications.
Attachments:
1. Request for Information_CRAC Units and Chillers (fill out)
2. DRAFT Statement of Work
3. DRAFT Salient Characteristics
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Request for Quotes - Remove and Replace CRAC Units and Chillers | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Troubleshoot & Repair of Portable Chillers Service Requirement | Air Education and Training Command | Total Small Business | |
| Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement | Air Education and Training Command | No set-aside | |
| CRAC Maintenance Service | Ohio National Guard | Total Small Business | |
| 4120--rental of two chillers for one year | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Two sets of HVAC units or Mobile Ground Control Station | Shared Services Center | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity