Replace KC-135 Maintenance Hangar
Awarded Award Notice Posted
- Solicitation number
- W912JD-10-R-0001
- Agency
- Maine National Guard Army National Guard, Department of Defense
- Awarded
- to Sheri - Key
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- W912JD-10-C-0001 Federal contract award
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Not on record
- Place of performance
- 101 ARW Bangor International Airport Bangor, Maine 04401, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Added: Dec 18, 2009 2:01 pm The purpose of this action was to attach the Site Visit Sign-In Sheet and the PowerPoint Slides used by Burns and McDonnell and the USPFO for Maine during the Site Visit which occurred on December 15, 2009 at 9:00am (EST).
Update #1 ·
Added: Nov 16, 2009 3:31 pm
Document Type: Pre-solicitation Notice
Solicitation Number: W912JD-10-R-0001
Title: Replace KC-135 Maintenance Hangar
Location: 101 ARW, Bangor International Airport, Bangor, Maine
Issue Date: 01 December 2009
Closing Date: 20 January 2010
Price Range: Magnitude of the project is between $10,000,000 and $25,000,000
Media: WebPages
Contracting POC: Lt Col Robert P Crowley Phone: (207) 430-5596
Primary Alternate POC: Mr. Robert B Busch Phone: (207) 990-7067
Secondary Alternate POC: Mr. David W McPhail Phone: (207) 430-5639
NAICS: 236220 - Hangar Construction
SIC: 1542
Synopsis: This solicitation is set-aside 100% for small business concerns. The small business size standard is $33.5 Million average annual revenue for the previous 3 (three) years. Standard bonding applies and will be required for this acquisition. This solicitation shall include FAR clause 52.225-11, Buy American Act-Construction Materials under Trade Agreements.
The Project: The new 78,000 aircraft maintenance hangar will replace the existing 45-year-old maintenance hangar located at the Bangor International Airport located in Bangor, Maine. The project consists of a long-span aircraft maintenance bay, general-purpose maintenance shops, a second floor administration area and building utility spaces.
The proposed site is located at the northwest corner of the existing light duty apron, east of the existing T9 Hush House, and west of the existing parking area located directly west of the existing Hangar. Demolition includes removal of existing pavements, foundations and utilities and deconstruction and removal of the existing after completion of the new hangar. Site improvements include new utilities, new apron, drainage improvements, fencing, drives, parking lots, and associated landscaping.
The pre-engineered metal building structural system of the hangar bay will be long-span steel truss frames or deep plate girder frames. The pre-engineered metal building system of the adjoining shops and administration areas will be standard plate girder frames with light-gage "Z" purlins to support the roof. The structure shall be supported on shallow foundations. Exterior walls will be constructed of vertical and horizontal pre-finished insulated metal panels, translucent panels, brick veneer and exposed concrete stem wall. The composite roofing system shall be a pre-finished structural standing seam metal roof over rigid insulation on a pre-finished metal liner panel. Horizontal-sliding doors with individually operated leaves and a separate tail door shall be provided for aircraft access to the hangar.
Plumbing systems will include compressed air, breathing air, aircraft wash and soap concentrate, and domestic hot and cold water. Mechanical HVAC systems include in-floor radiant heat with back-up forced air for the hangar, and 4-pipe forced air system with fan coil units for shops and administrative space. Chilled water will be provided by a packaged, scroll, air cooled chiller (approximately 70 Ton) and hot water will be provided by three 40-percent capacity condensing, natural gas-fired hot water boilers. The hangar will be protected by an overhead pre-action fire sprinkler system and a supplemental low-level high expansion foam system. All other areas of the building will be protected by a hydraulically designed wet-pipe automatic sprinkler system. Electrical systems include primary and secondary power, lighting, grounding, 400-hertz power, fire alarm, voice and data cabling, PA, CATV/CCTV, and security and alarm.
The project will be LEED Silver Certified under USGBC Version 2.2 Guidelines.
There are option items included in the solicitation. The magnitude of construction, as defined in DFARS 236.204, is between $10,000,000 and $25,000,000. The acquisition method is a source selection process conducted in accordance with FAR Part 15.3 and DFARS Part 215.3 entitled Source Selection Procedures. Evaluation factors are past performance and price which are approximately equal. Evaluation by the Government will result in selection of a firm that represents the best value to the Government. A single Firm-Fixed Price award without discussions is anticipated. This solicitation will be issued via Internet only. Notification of amendments shall be made via Internet only, as well. It is therefore the contractor's responsibility to check the following address daily for any posted changes to this solicitation. For security reasons, all technical and engineering data related to this solicitation will be distributed using the federal Business Opportunity (FBO) System. FBO is a web-based dissemination tool designed to safeguard acquisition-related information for all Federal Agencies. Interested offerors must register with FBO or they will not be able to download information from the site. Registration instructions can be found on the FedBizOpps website at https://www.fbo.gov by clicking on the "Register Now" hyperlink. Contractors registered with FBO may view and/or download this solicitation and all amendments from the Internet AFTER SOLICITATION ISSUANCE. All offerors are encouraged to visit the Army Single Face to Industry website at https://acquisition.army.mil/asfi to view other business opportunities. Offerors are encouraged to post notices of prospective subcontracting opportunities on the FedBizOpps website at https://www.fbo.gov. Offerors are advised that this requirement may be delayed, cancelled, or revised at any time during the solicitation, or final award process, and is subject to availability of funds. Funds are not currently available. Project number FKNN089019 is a high priority project and approval has been obtained from PARC to authorize solicitation of bids without obtaining assurance of current fund availability. This requirement is included or provided for in the MILCON Program for FY 2010. Contractors must be registered in the Central Contractor Registration (CCR) before an award can be made. Please see the CCR website at http://www.ccr.gov to register. Requests for information concerning this solicitation can be made to Lt Col Robert P Crowley at (207) 430-5596, e-mail: Robert.P.Crowley@us.army.mil, or Mr. Robert B Busch at (207) 990-7067, e-mail: Robert.Busch@ang.af.mil, or Mr. David W McPhail at (207) 430-5639, e-mail: David.McPhail@us.army.mil.
Attachments
Show all 50
This notice has more attachments on GovTribe.
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity