Renovate PTS Fire Suppression System - Mike Monroney Aeronautical Center - Oklahoma City
Closed Solicitation Posted
- Solicitation number
- 6973GH-22-R-00075
- Agency
-
Franchise Acquisition Servies
Federal Aviation Administration, Department of Transportation
- Responses due
- Set-aside
- Competitive 8(a)
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Oklahoma City, Oklahoma 73169, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks to renovate the fire suppression system at the Mike Monroney Aeronautical Center in Oklahoma City, Oklahoma. The scope of work includes upgrading the fire suppression, fire alarm, ceiling, and lighting systems for the Powered Training Systems facility. The Department of Transportation Federal Aviation Administration Franchise Acquisition Services is the contracting agency seeking a contractor to complete the work in accordance with the project drawings, specifications, and direction of the Contracting Officer's Representative. The evaluation criteria include past performance on similar projects, with surveys due by May 24, 2022. Proposals for the work must be submitted by May 27, 2022.
This opportunity is set aside for competitive 8(a) small businesses. The primary NAICS code is 238210 and PSC code R499. The estimated price range for the contract value is between $1,000,000 and $5,000,000. The construction site is located at the Powered Training Systems facility, building B232, at the Mike Monroney Aeronautical Center campus in Oklahoma City, Oklahoma 73169. The contractor must order materials in advance and have them on-site prior to each phase's start date to complete the work between October 2022 and January 2023.
Notice text
The scope of work for the PTS Replace Fire Suppression System at the Mike Monroney Aeronautical Center in Oklahoma City, OK includes:
1. Description of Facility:
1.1 Building Area: 39,014 SF
1.2 Building Age: Built 10-31-2005
1.3 Building Function: Training, classrooms, admin. spaces, etc.
2. Description of Work:
2.1 Upgrade fire suppression, fire alarm system, ceiling system and lighting in the PTS facility.
3. All work done must meet all the requirements spelled out in the project drawings and specifications and/or as directed by the Contracting Officer’s Representative (COR). All components must be UL listed and other applicable standards listed in the project specification approved by the COR. All work done must be approved by the COR.
4. The contractor must pre-order and have materials on-site prior to phasing start dates to accomplish each phase of work.
5. Prior to the start of any construction work, the contractor and sub-contractors are required to pre-order all materials required to complete the work scheduled to ensure all materials are delivered to work site prior to start of work.
B. The construction site located at: PTS B232 Mike Monroney Aeronautical Center (MMAC) 6100 S.W. 61 Street, Oklahoma City, OK 73169.
Files
Show all 37
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221 | Air Force Sustainment Center | Total Small Business | |
| WWYK250063 - install react VII facility, B9001, post V19 | Air Force Sustainment Center | Woman-Owned Small Business | |
| Mike Monroney Aeronautical Center (MMAC) Industrial Waste Water Treatment Plant Upgrades | Franchise Acquisition Servies | Total Small Business | |
| Mechanical Construction Services IDIQ - MMAC | Franchise Acquisition Servies | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity