PTS Fire and Lighting Reno-20220107_Dwgs.pdf

PDF 15 MB Posted

Attached to
Renovate PTS Fire Suppression System - Mike Monroney Aeronautical Center - Oklahoma City
Solicitation number
6973GH-22-R-00075
Issued by

About this file

This document outlines a federal contract opportunity to renovate the fire suppression system at the Mike Monroney Aeronautical Center in Oklahoma City, Oklahoma. The scope of work includes upgrading the fire suppression, fire alarm system, ceiling system and lighting for the Professional Training School facility located at 6100 S.W. 61 Street. All work must be completed according to the project drawings, specifications and direction of the Contracting Officer's Representative. Materials must be pre-ordered and on site prior to scheduled phases to ensure timely completion. The solicitation was issued by the Department of Transportation Federal Aviation Administration Franchise Acquisition Services under number 6973GH-22-R-00075.

View the file

Other files

File Type Posted
98-0225PS600.pdf PDF
98-0225PS710.pdf PDF
Sidewalk Canopy _98-0225PL502.pdf PDF
98-0225PS002.pdf PDF
98-0225PS601.pdf PDF
98-0225PS700.pdf PDF
98-0225PS603.pdf PDF
98-0225PS003.pdf PDF
98-0225PS604.pdf PDF
98-0225PS001.pdf PDF
98-0225PS100.pdf PDF
98-0225PS703.pdf PDF
98-0225PS301.pdf PDF
98-0225PS005.pdf PDF
98-0225PS702.pdf PDF
98-0225PS711.pdf PDF
98-0225PS701.pdf PDF
Past Performance Survey.pdf PDF
98-0225PS602.pdf PDF
98-0225PS004.pdf PDF
6973GH-22-R-00075-0001.pdf PDF
98-0225PS300.pdf PDF
213000 FIRE PUMP ENCLOSURE.pdf PDF
SHEET FS-6 FIRE WATER PLAN.pdf PDF
Pre Bid RFIs with Responses.pdf PDF
Past Performance Survey.pdf PDF
Client Authorization Letter.pdf PDF
SF 25 Performance Bond.pdf PDF
Wage Rate Determination - 25 Feb 22.pdf PDF
6973GH-22-R-00075.pdf PDF
Contractors Release.pdf PDF
SF25A - Payment Bond.pdf PDF
SOW WO 20-004873 PTS Replace Fire Suppression 1-21-22.pdf PDF
Operational Controls.pdf PDF
Chapter_33-Construction Safety.pdf PDF
PTS Fire and Lighting Reno_220107_Specs.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a

"need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of

Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.

Oklahoma City, Oklahoma 73169

FAA-MMAC 232-PTS Fire Suppression System and Lighting Renovation

SHEET INDEX

Type B Design - Issued For Construction

W.O. 2020-004873

Contract # DTFAAC-16-D-00037 ORDER 011

Fire Protection Engineers:

The Small Group, LLC

108 South Broadway

Edmond, Oklahoma 73034

405.840.1111 ( T )

405.840.1191 ( F ) www.smallarchitects.com

8101 S. MacArthur Blvd.

January 7, 2022

Electrical Engineers:

01/06/2022 is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a

"need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of

Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.

is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a

"need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of

Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.

{NOTE}:

ALL "EMERGENCY" FIXTURES ARE

CONNECTED TO GENERATOR

POWER.

%%U GENERAL NOTES %%U

1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH NFPA

70-2020 (NATIONAL ELECTRICAL CODE), AND APPLICABLE PROVISIONS

OF ALL FEDERAL, STATE AND LOCAL CODES, STANDARDS, AND

ORDINANCES.

2. DRAWINGS, DETAILS, AND DIAGRAMS ARE BASED ON AVAILABLE

AS-BUILT DOCUMENTS AND LIMITED FIELD OBSERVATIONS. ACTUAL

LAYOUTS AND CONFIGURATIONS MAY NOT BE EXACTLY AS SHOWN.

COORDINATE ALL WORK WITH CONDITIONS ENCOUNTERED.

3. CLOSELY SCHEDULE AND COORDINATE ALL WORK WITH ONGOING

ACTIVITIES AND WORKFLOWS IN OCCUPIED AREAS OF THE FACILITY.

OBTAIN HOT WORK PERMIT PRIOR TO ANY WORK ON ENERGIZED

EQUIPMENT.

4. CONDUITS INSTALLED UNDER THIS PROJECT SHALL BE ELECTRICAL

METALLIC TUBING (EMT), 3/4" TRADE SIZE MINIMUM, EXCEPT THAT

LIQUID TIGHT FLEXIBLE METAL CONDUIT (LTFMC) SHALL BE USED FOR

ALL INTERIOR AND EXTERIOR MECHANICAL EQUIPMENT AND FIXTURE

CONNECTIONS. RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE

USED WHERE SPECIFICALLY REQUIRED. METAL CLAD (MC) CABLE IS

NOT ALLOWED.

5. NO MORE THAN FOUR STANDARD LIGHT FIXTURE WHIPS SHALL BE

CONNECTED TO EACH J-BOX. LIGHT FIXTURES SHALL NOT BE DAISY

CHAINED, CIRCUIT THROUGH ASSOCIATED JUNCTION BOX.

6. ALL CONTROL CIRCUITING SHALL BE INSTALLED IN CONDUIT,

SEPARATE FROM 277V LIGHTING CONDUITS.

7. ALL ELECTRICAL POWER DISTRIBUTION AND BRANCH CIRCUIT

CONDUCTORS SHALL BE 600V TYPE THHN

8. POWER AND RECEPTACLE CIRCUITS SHALL BE #12 AWG MINIMUM.

HOMERUNS FOR 120V BRANCH CIRCUITS OVER 100 FEED LONG SHALL

BE #10 AWG MINIMUM.

9. PROVIDE ALL POWER AND CONNECTIONS TO EQUIPMENT PER

MANUFACTURER'S RECOMMENDATIONS. ELECTRICAL REQUIREMENTS

INCLUDING CIRCUIT BREAKER SIZES, FUSE SIZES, AND CONDUCTOR

SIZES ARE BASED CHARACTERISTICS INDICATED AND MAY VARY

DEPENDING ON EQUIPMENT PROVIDED. COORDINATE ALL ELECTRICAL

REQUIREMENTS WITH EQUIPMENT SUPPLIED AND REVISE IF

NECESSARY.

10. REVISE EXISTING PANELBOARD DIRECTORIES, LOAD

IDENTIFICATION PLACARDS, AND SIMILAR IDENTIFYING MECHANISMS

TO REFLECT LOADS AS ADDED, REVISED, OR REMOVED UNDER THIS

PROJECT.

11. ROUTE CONDUIT TO ROOF MOUNTED EQUIPMENT BELOW ROOF

INSOFAR AS PRACTICABLE. TRANSITION TO ROOFTOP WITHIN

EQUIPMENT CURB WHERE POSSIBLE. COORDINATE ANY ROOFING

PENETRATIONS WITH ARCHITECTURAL. DO NOT ROUTE ON ROOF.

%%U LIGHTING PLAN - DEMOLITION

{NOTES:}

1. RETAIN ALL EXISTING LIGHTING CIRCUITS AND FIXTURE WHIPS INSOFAR AS

PRACTICABLE.

2. SHADED FIXTURES INDICATE FIXTURES CONNECTED TO EMERGENCY GENERATOR

CIRCUITS.

REMOVE 2'x4' FLUORESCENT LENSED TROFFER

REMOVE FLUORESCENT INDUSTRIAL STRIP. RETAIN MOUNTING HARDWARE FOR REUSE IF PRACTICABLE.

REMOVE LINEAR FLUORESCENT STRIP

REMOVE COMPACT FLUORESCENT DOWNLIGHT.

REMOVE METAL HALIDE SPHERICAL FLOODLIGHT.

REMOVE METAL HALIDE IN-GROUND UPLIGHT

REMOVE METAL HALIDE BOLLARD

REMOVE METAL HALIDE UP/DOWN LIGHT.

REMOVE TWIN-HEAD WALL MOUNTED EMERGENCY FIXTURE

REMOVE EXIT SIGN

120V OR 277V LIGHTING CIRCUIT CONDUIT AND WIRING. ARROWHEADS, WHERE USED, DENOTE HOMERUN(S) TO LIGHTING CONTROL PANEL OR PANELBOARD IN ELECTRICAL ROOM.

EXISTING WALL SWITCH, TO REMAIN.

OC REMOVE EXISTING CEILING MOUNTED MOTION DETECTOR. RETAIN WIRING FOR NEW SENSOR.

NEW CONDUIT AND WIRE CONNECTED AS INDICATED. 1/2"C MIN WITH #12 AWG. MIN. CONDUCTORS UNLESS NOTED OTHERWISE. NEW WIRING IS SHOWN DARKER THAN EXISTING WIRING TO REMAIN.

PHASE CONDUCTOR(S)

NEUTRAL CONDUCTOR(S)

GROUNDING CONDUCTOR

NEW WALL SWITCH IN EXISTING BOX, 120/277V, 20A. PULL NEW WIRING TO SWITCH

WHERE NECESSARY.

3 = 3-WAY SWITCH

4 = 4-WAY SWITCH

EXISTING 120 OR 277V LIGHTING CIRCUIT CONDUIT AND WIRING. ARROWHEADS, WHERE USED, DENOTE HOMERUN(S) TO EXISTING PANELBOARD AND CIRCUIT IN ELECTRICAL ROOM 104.

EXISTING WALL SWITCH TO REMAIN IN USE.

NEW LIGHTING FIXTURES

SD WALLBOX DIMMER WITH 0-10V CONTROL OUTPUT EQUAL TO LUTRON #DVSTV-WH.

OC

DL

WALL MOUNTED LINE VOLTAGE OCCUPANCY SENSOR EQUAL TO LUTRON #MS-A102-WH. MOUNT IN EXISTING SWITCH WALLBOX.

CEILING MOUNTED OCCUPANCY SENSOR EQUAL TO LUTRON #LOS-CDT-2000-WH "INCLUDING ALL NECESSARY POWER PACKS, HARDWARE, AND ACCESSORIES.", REPLACE EXISTING SENSOR AT SAME LOCATION.

DAYLIGHT SENSOR EQUAL TO LUTRON #EC-DIR-WH "INCLUDING ALL NECESSARY POWER PACKS, HARDWARE, AND ACCESSORIES."

%%U LIGHTING PLAN - REVISED

%%U SYMBOL LEGEND

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

DESIGNED

WORK ORDER NO.

DRAWN

OFFICE OF

FACILITY MANAGEMENT

ISSUED BY

AMP-300

DATE

FEDERAL AVIATION ADMINISTRATION

PREPARED BY

REV DATE

DEPARTMENT OF TRANSPORTATION

APPROVED BY

DESCRIPTION APP'DCHECK

OF

SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.

SMALL ARCHITECTS

07 JAN 2022

MARSHALL G. MAGGARD

REVIEWED BY

DRAWING NO.

ISSUED FOR CONSTRUCTION SUBMISSION

Z R

H D

P .C

C

E R

T

IF

IC

A

T E

O F

A U

T H

O R

IZ

A

T

IO

N C

A

E X

P

IR

A T

IO

N

D A

T E

J

U N

E

{\C 1;

H

SM

A0 3\

\A c

2020-004873

\pxqc;232-PTS FIRE SUPPRESSION SYSTEM AND LIGHTING RENOVATION

E.001

ELECTRICAL LEGEND &

LIGHT FIXTURE SCHEDULE

MRS

MDR

S

SE

SE

SOC

SS REMOVE INBOARD/OUTBOARD SWITCHES. BOX, CONDUIT, AND WIRING TO REMAIN. INSTALL BLANK COVER ON UNUSED BOX.

LIGHT FIXTURE SCHEDULE

TYPE DESCRIPTION LAMP QTY LAMP TYPE MAX FIXTURE WATTS DELIVERED LUMENS VOLTS MANUFACTURER OR APPROVED EQUAL NOTES

"A" 2' X 4' RECESSED STATIC TROFFER N/A LED 32.1 4014 120/277V

LSI INDUSTRIES

LPEC24-LED-40L-UNV-DIM1-40-FC15D

LAY-IN-GRID.

PROVIDE SHADED "A" FIXTURES WITH EMERGENCY BALLAST

"A1" 2' X 4' RECESSED STATIC TROFFER N/A LED 23.9 3033 120/277V

LSI INDUSTRIES

LPEC24-LED-30L-UNV-DIM1-40-FC15D

LAY-IN-GRID.

PROVIDE SHADED "A1" FIXTURES WITH EMERGENCY BALLAST

"A2" 2' X 4' RECESSED STATIC TROFFER N/A LED 42 5548 120/277V

LSI INDUSTRIES

LPEC24-LED-55L-UNV-DIM1-40-FC15D

LAY-IN-GRID.

PROVIDE SHADED "A2" FIXTURES WITH EMERGENCY BALLAST

"A3" 2' X 4' RECESSED STATIC TROFFER N/A LED 63.4 8080 120/277V

LSI INDUSTRIES

LPEC24-LED-80L-UNV-DIM1-40-FC15D

LAY-IN-GRID.

PROVIDE SHADED "A3" FIXTURES WITH EMERGENCY BALLAST

"A4" 2' X 4' RECESSED STATIC TROFFER - NON-DIMMED N/A LED 42 5548 120/277V

LSI INDUSTRIES

LPEC24-LED-55L-UNV-DIM1-40-FC1

LAY-IN-GRID.

PROVIDE SHADED "A4" FIXTURES WITH EMERGENCY BALLAST

"B" 8" ROUND RECESSED DOWN LIGHT N/A LED 13.5 1576 277

GE CURRENT

LRC-8R-B-4-15-WD-CL-SD-MR-8-40-VQ-WR

RECESSED.

PROVIDE SHADED FIXTURES WITH EMERGENCY BALLAST

"C" 1' X 4' RECESSED STATIC TROFFER N/A LED 51 6547 120/277V

LSI INDUSTRIES

LPEC14-LED-65L-UNV-DIM1-40-FC1 RECESSED.

"F" 4' LINEAR LENSED LED STRIP N/A LED 30.1 3879 120/277V

LSI INDUSTRIES

SDL4-LED-40L-FL-UNV-DIM1-40-80CRI

SURFACE.

PROVIDE SHADED FIXTURES WITH EMERGENCY BALLAST

"F1" 8' LINEAR LED STRIP N/A LED 89.8 12062 120/277V

LSI INDUSTRIES

SDL8-LED-120L-FL-UNV-DIM1-40-80CRI

SURFACE.

PROVIDE SHADED FIXTURES WITH EMERGENCY BALLAST

"F2" 4' LINEAR LENSED LED STRIP N/A LED 52.8 7025 120/277V

LSI INDUSTRIES

SDL4-LED-70L-FL-UNV-DIM1-40-80CRI

SURFACE.

PROVIDE SHADED FIXTURES WITH EMERGENCY BALLAST

"F3" 8' LINEAR LED STRIP N/A LED 123.7 16047 120/277V

LSI INDUSTRIES

SDL8-LED-160L-FL-UNV-DIM1-40-80CRI

SURFACE.

PROVIDE SHADED FIXTURES WITH EMERGENCY BALLAST

"H" EXTERIOR WALL MOUNTED LED LIGHT N/A LED 39 3104 120/277V

LIGMAN LIGHTING USA

UJE-30391-39W-W-W40-01-120/277V MOUNT AT EXISTING LOCATION OF REMOVED FIXTURE.

"J" EXTERIOR WALL MOUNTED LED LIGHT N/A LED 40 5669 120/277V

ILP LIGHTING

SWP-5L-U-CCTS-BRZ MOUNT AT EXISTING LOCATION OF REMOVED FIXTURE.

"K" 2' X 2' RECESSED STATIC TROFFER N/A LED 21.3 2570 120/277V

LSI INDUSTRIES

LPEC22-LED-25L-UNV-DIM1-40-FC1

LAY-IN-GRID.

PROVIDE SHADED FIXTURES WITH EMERGENCY BALLAST

"K1" 2' X 2' RECESSED STATIC TROFFER - RECESSED N/A LED 21.3 2570 120/277V

LSI INDUSTRIES

LPEC22-LED-25L-UNV-DIM1-40-FCI-FK22

RECESSED.

PROVIDE SHADED FIXTURES WITH EMERGENCY BALLAST

"L" INTERIOR WALL MOUNTED LED LIGHT - INDIRECT WALLWASH N/A LED 100 10900 120/277V

METEOR LIGHTING

RI-110L-408-UNV-STV-ASY-XX-WLM MODIFY COLOR TO BE SILVER. MOUNT AT EXISTING LOCATION OF REMOVED FIXTURE.

"M" EXTERIOR WALL MOUNTED LED LIGHT N/A LED 39 3104 120/277V

LIGMAN LIGHTING USA

UJE-30391-39W-N-W40-05-120/277V MOUNT AT EXISTING LOCATION OF REMOVED FIXTURE.

"X" UNIVERSAL MOUNTED LED EXIT SIGN, RED GRAPHICS. N/A LED 2.7 N/A 120/277V

LSI INDUSTRIES

EX-R-U-WB-WH-SD2 WALL MOUNT WHERE FEASIBLE, OTHERWISE CEILING MOUNT. WITH SELF-CONTAINED EMERGENCY BATTERY.

"AA" RECESSED IN GROUND LED UPLIGHT N/A LED 35 2500 277

LIGMAN LIGHTING

UKI-60771-30W-W-W40-120/277V-F

BB' 20' POLE WITH TWIN HEAD LED AREA LIGHTS N/A LED 62 9926 277

LSI INDUSTRIES

MRM-LED-24L-SIL-3-UNV-DIM-40-70CRI-BLK PROVIDE WITH #BKA-UMB-BLK MOUNTING BRACKET

"CC" 44" TALL LED DECORATIVE BOLLARD N/A LED 41 991 120/277V

LSI INDUSTRIES

MRB-LED-25L-ACR-S-UNV-DIM-40-PLP

POWER

PACK LIGHTING LOAD

BLUE (SIGNAL)

RED (+20 - 24V)

BLACK (COMMON)

NOTE: MAXIMUM 3 OCCUPANCY SENSORS.

120/277/347V~, 60HZ;

230V~, 50/60HZ

LINE

NEUTRAL

WHITE

BLACK

RED

RED

%%U OCCUPANCY SENSOR WIRING DIAGRAM

NOT TO SCALE

POWER TRAINING

SUPPORT FACILITY

(#232)

GNAS

(#195)

AS

R

-8

TR

AI

N

IN

G

LA

B

9)

HAZARDOUS

MATERIALS

(#192)

S .W s t S

T

S .W n d S

T

ARSR-3

ENGINE

GENERATOR

(#162)

AS

R

-8

ST

O R

B

LD

G

3) AS

R -8

TO

W

ER

5)

\pxql;GOV VEH

\pxql;GOV VEH

CC

AA

BB

AA206

AA206

AA206

AA206

AA206

AA206

AA206

E.002

ELECTRICAL SITE PLAN

WHW

MDR

SCALE:

E002

ELECTRICAL SITE PLAN

1"=20'-0"N

O R

TH

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

DESIGNED

WORK ORDER NO.

DRAWN

OFFICE OF

FACILITY MANAGEMENT

ISSUED BY

AMP-300

DATE

FEDERAL AVIATION ADMINISTRATION

PREPARED BY

REV DATE

DEPARTMENT OF TRANSPORTATION

APPROVED BY

DESCRIPTION APP'DCHECK

OF

SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.

SMALL ARCHITECTS

07 JAN 2022

MARSHALL G. MAGGARD

REVIEWED BY

DRAWING NO.

ISSUED FOR CONSTRUCTION SUBMISSION

Z R

H D

P .C

C

E R

T

IF

IC

A

T E

O F

A U

T H

O R

IZ

A

T

IO

N C

A

E X

P

IR

A T

IO

N

D A

T E

J

U N

E

{\C 1;

H

SM

A0 3\

\A c

2020-004873

\pxqc;232-PTS FIRE SUPPRESSION SYSTEM AND LIGHTING RENOVATION

020' 10' 20'

\pxi-4,l4,a0.66667,sm1.07917;1. ALL EXISTING UNDERGROUND UTILITIES AND PARKING LOT LIGHTING TO REMAIN AND IN USE DURING CONSTRUCTION AND NOT MODIFIED IN THIS PROJECT.

%%UELECTRICAL SITE PLAN GENERAL NOTES

EXISTING UNDERGROUND CONDUIT AND

EXISTI

REPLACE EXISTING

CONNECT TO EXISTING CIRCUIT 1N4B-14, VIA LC-2.

%%U KEYED NOTES THIS SHEET %%U

PODIUM

PODIUM

C O

PI

ER

(F

LO

O R

FRID

GE

APPLIED SURFACE (WALLTALKER)

8' PROJECTOR SCREEN

8' PROJECTOR SCREEN

APPLIED SURFACE (WALLTALKER)

APPLIED SURFACE (WALLTALKER)

PO

DIU

M

FFFF

PB

F

PB

F

FF BB

F

FFBBF

FFBB

F

FF

FF

BBF

FF

BBF

STORAGE

CABINET

B O

O K

C A

S E

B O

O K

C A

S E

C O

PI

ER

(F

LO

O R

STORAGE

CABINET

STORAGE

CART

FC

STORAGE

CABINET

FF

STOR

AGE

CABIN

ET

LF

ST

OR

AG

E C

AB

INE

T

TO

O

L C

AB

IN

ET

"X

TO

O

L C

AR

T

"X

TA

BL

E

"X

TA

BL

E 36 "X

TA

BL

E

36"X48"

TABLE

36"X48"

TABLE

"X

TA

BL

E

"X

TA

BL

E36"X48"

TABLE

"X

W

IR

E

SH

EL

F

36"X60"30"X48

FCFC

VESTIBULE

100A

127126125

TELESYST FIRE RISER

ROOM

CORRIDOR

101A

STORAGE

JAN.

WOMEN

MEN

100B

113A

111114

120A 118A

STORAGE

BATTERY ROOM

UPS STORAGE

LAB STORAGE

CHILLER

BOILER

UPS ROOM

GENERATOR ROOM

LAB

GENERATOR ROOM

BATTERY ROOM

CLASSROOM

CLASSROOM

CLASSROOM

LABORATORY

LABORATORY

100C

LABORATORY

OPEN OFFICE

AMP-200

121A

123A 124A

119A

OPEN OFFICE

STORAGE

102A

OFFICE

102B

8' PROJECTOR SCREEN

SWITCH GEAR ROOM

H

H

H

M

M

M

M

MMMM

A A

A A

A A

A

CC

C C

DD

DD

F

S E

F F F

SE SE SE

F F

F F

F F

F F

F F

C

SESE

F

F

F

F

F

F

S E

1N4B-2,12,14

E

E

E1

E

E1

E

E

E

E

E

E

E

K K K K

J 14

S

G

G

SS

A

A A

A A

A A

A

A A A

AAA

S S

S D

A1

A1A1A1

A A A A

AAAA

1N4B-4,6,26

J

J

E1

E

E

E

E

E

E

E

J

E1

E

E

E

E

E

E

E

J

J

JJJ

1N4A-22,24,26,28

E1

E

E

E

E

E

E

E

J

JJ SESESSE S3E S3E SE

S S

S3E S3E

J

J

J

F1

F1

1N4A-10,12

1N4A-14,16,18,20

A A

A

AA

A

A

A

A

F

F F

F

FF

F

F F

F

F

F

FFF

F F

FF

F1

F1

F1

F1

F1

F1

F1

F1 F1

F1

F1

F1

F1 F1 F1

F1 F1

F1

F1

F1

F1

F1F1

F1

F1

F1F1

F1

E

J

E

E

E1

S E

J

J

J

S E

S

4, 1N4A-2,4,6

A

A

A

S S

S S

A A A

AAA

A A A

A

A

A A

A

A A

A

A A

A

A

1N4B-10

J

1E4A-2,4

B

K1

A1 A1 A1

A1

A1 A1 A1

A1

A A A A

AAAA

A A A A

AAAA

A A A

AAA

A A A

A A A

A A A

A A A

K K

K

S S

S D

S S S

D

1N4B-8,12,14

S S

S S

B

B

S 3E

S3E SE

S S

(NL)

OC

OC

S

S

S

S

S3 S3 S3 S3SS

"1E4A"

"1N4A"

"LC1"

(NL)

(NL)

(NL)

S

S E

E

E

E

E

E E

E

E

E

E

J

J

S S104

SS

104107

101101

101101

101101101

101101

101101

101101

103102

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

B

1N4A-12

1N4B-12,14p.c.

1N4B-12,14p.c.

ED.101

DEMOLITION LIGHTING PLAN

WHW

MDR

SCALE:

ED101

DEMOLITION LIGHTING PLAN

1/8"=1'-0"N

O R

TH

16'8'4'8' 0

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

DESIGNED

WORK ORDER NO.

DRAWN

OFFICE OF

FACILITY MANAGEMENT

ISSUED BY

AMP-300

DATE

FEDERAL AVIATION ADMINISTRATION

PREPARED BY

REV DATE

DEPARTMENT OF TRANSPORTATION

APPROVED BY

DESCRIPTION APP'DCHECK

OF

SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.

SMALL ARCHITECTS

07 JAN 2022

MARSHALL G. MAGGARD

REVIEWED BY

DRAWING NO.

ISSUED FOR CONSTRUCTION SUBMISSION

Z R

H D

P .C

C

E R

T

IF

IC

A

T E

O F

A U

T H

O R

IZ

A

T

IO

N C

A

E X

P

IR

A T

IO

N

D A

T E

J

U N

E

{\C 1;

H

SM

A0 3\

\A c

2020-004873

\pxqc;232-PTS FIRE SUPPRESSION SYSTEM AND LIGHTING RENOVATION

1. UNLESS NOTED OTHERWISE, ALL LIGHTING FIXTURES

SHOWN ON THIS PLAN WILL BE REPLACED WITH NEW LED

LIGHTING FIXTURES AS INDICATED ON SHEET E.101. NEW

LIGHTING FIXTURES SHALL BE INSTALLED IN SAME

LOCATION USING EXISTING JUNCTION BOXES, CONDUIT, AND

WIRING.

2. ALL DARKENED CONDUIT AND WIRING SHOWN SHALL BE

REMOVED IN ITS ENTIRETY BACK TO SOURCE.

3. ALL LIGHT FIXTURES WITH INTERNAL HATCHING ARE

CIRCUITED TO THE BUILDINGS EXISTING EMERGENCY

LIGHTING SYSTEM/GENERATOR AND SHALL REMAIN ON THAT

CIRCUIT.

4. ALL EXISTING CEILING MOUNTED DEVICES OTHER THAN

LIGHTING FIXTURES AND OCCUPANCY SENSORS ARE TO

REMAIN AND IN USE DURING CONSTRUCTION. IF ANY

DEVICE IS DAMAGED DURING CONSTRUCTION, IT SHALL BE

REPLACED WITH IDENTICAL DEVICE AND THE SYSTEM SHALL

BE RECERTIFIED AS REQUIRED BY AHJ. DEVICES TO REMAIN

INCLUDE BUT ARE NOT LIMITED TO: SPEAKERS, FIRE ALARM

DEVICES, COMMUNICATION DEVICES, SECURITY DEVICES,

%%UDEMOLITION LIGHTING GENERAL NOTES

DEMOLISH EXISTING FIXTURE AND ALL

EXISTING 3-WAY SWITCHES TO REMAIN AND IN USE.

REPLACE EXISTING SWITCH WITH NEW

EXISTING LV MASTER SWITCH TO BE

EXISTING LIGHTING CONTROL PANEL TO BE

REMOVE EXISTING TOGGLE SWITCH,

REMOVE 2 EXISTING

REMOVE EXISTING DIMMER SWITCH AND REPLACE WITH NEW DIMMER SWITCH.

DEMOLISH EXISTING WALL MOUNTED SWITCH,

VESTIBULE

100A

127126125

TELESYST FIRE RISER

ROOM

CORRIDOR

101A

STORAGE

JAN.

WOMEN

MEN

100B

113A

111114

120A 118A

STORAGE

BATTERY ROOM

UPS STORAGE

LAB STORAGE

CHILLER

BOILER

UPS ROOM

GENERATOR ROOM

LAB

GENERATOR ROOM

BATTERY ROOM

CLASSROOM

CLASSROOM

CLASSROOM

LABORATORY

LABORATORY

100C

LABORATORY

OPEN OFFICE

AMP-200

121A

123A 124A

119A

OPEN OFFICE

STORAGE

102A

OFFICE

102B

SWITCH GEAR ROOM

S E

SE SE SE

SESE

S E

1N4B-2,12,14 J 14

1N4B-4,6,26

J

J

JJ

J

1N4A-22,24,26,28

J

JJ SESESE S3E S3E SE

S3E S3E

1N4A-10,12

1N4A-14,16,18,20

S E

S

E

4, 1N4A-2,4,6

1N4B-10

1E4A-2,4 1N4B-8,12,14

S 3E

S3E SE

S

S

S

S

S3 S3 S3 S3

"1E4A"

"1 N

4A

S E

H

H

H

M

M

M

M

MMMM

JJJ

J

J

J

J

J

J

J

J

J

A4 A4

A4 A4

A4 A4

A4

CC

C C

FF

FF

F

F F F

F F

F F

F F

F F

F F

C

F2

F2

F2

F2

F2

F2

K K K K

A

A

A

A A

A A

A A

A

A A A

AAA

A

AAA

A A A A

AAAA

F3

F3

A3 A3

A3

A3A3

A3

A3

A3

A3

F

F F

F

FF

F

F F

F

F

F

FFF

F F

FF

F1

F1

F1

F1

F1

F1

F1

F1 F1

F1

F3

F3

F3 F3 F3

F3 F3

F3

F3

F3

F3

F3F3

F3

F3

F3F3

F3

A2

A2

A2

A2 A2 A2

A2A2A2

A2 A2 A2

A1

A1

A1 A1

A1

A1 A1

A1

A1 A1

A1

A1

B

K1

A A A

A

A A A

A

A A A A

AAAA

A A A A

AAAA

A A A

AAA

A A A

A A A

A A A

A A A

K K

K

B

B

(NL)

(NL)

(NL)

(NL)

B

F2 F2

F2

F2

F2

F2

F

F

F

F

F

F

F

F

F

F

F

F

A A A2A2

F

F

F

F

F

F

F

F

F2 F2 F2 F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2 F2

F2 F2 F2 F2

F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2 F2

F2

F2

F2 F2

F2

F2

F2 F2 F2

F2

F2F2

F2 F2

F2

F2

FFFFFF

FF FF FF

FF FF F

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2 F2 F2 F2F2 F2F2 F2F2 F2

F2

F2

F2 F2

F2 F2F2 F2F2 F2F2 F2F2 F2 F2 F2

F2 F2 F2 F2 F2 F2 F2 F2 F2

F2 F2 F2 F2 F2

F2 F2 F2 F2 F2 F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2F2

F2 F2F2 F2F2 F2

F2

F2

F2

F2

F2

F2

F2

F2

(NL)

X

X

X

X

SD

S

OC

S

OC

S D

S D

OC

OC

OC

OC

OC

DL

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

OC

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

(NL)

K

S D

S D

(NL)

S D

S D

S D

S D

S D

S D

S D

(NL)

(NL)

(NL)

S

OC

(NL)

(NL)

OC

OC

F3

S

(NL)(NL)

(NL)

(NL)

S

(NL) (NL)

(NL)

(NL)

(NL)

(NL)

(NL)

(NL)

(NL)

(NL)

(NL)

(NL)

(NL)

S

S

S

S

(NL)

S

S

103102

205 205

207207

OC

1N4A-12

1N4B-12,14p.c.

1N4B-12,14p.c.

F2

E.101

REVISED LIGHTING PLAN

WHW

MDR

SCALE:

E101

REVISED LIGHTING PLAN

1/8"=1'-0"N

O R

TH

16'8'4'8' 0

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

DESIGNED

WORK ORDER NO.

DRAWN

OFFICE OF

FACILITY MANAGEMENT

ISSUED BY

AMP-300

DATE

FEDERAL AVIATION ADMINISTRATION

PREPARED BY

REV DATE

DEPARTMENT OF TRANSPORTATION

APPROVED BY

DESCRIPTION APP'DCHECK

OF

SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520. No part of this record may be disclosed to persons without a "need to know", as defined in 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR parts 15 and 1520.

SMALL ARCHITECTS

07 JAN 2022

MARSHALL G. MAGGARD

REVIEWED BY

DRAWING NO.

ISSUED FOR CONSTRUCTION SUBMISSION

Z R

H D

P .C

C

E R

T

IF

IC

A

T E

O F

A U

T H

O R

IZ

A

T

IO

N C

A

E X

P

IR

A T

IO

N

D A

T E

J

U N

E

{\C 1;

H

SM

A0 3\

\A c

2020-004873

\pxqc;232-PTS FIRE SUPPRESSION SYSTEM AND LIGHTING RENOVATION

%%UREVISED LIGHTING GENERAL NOTES

EXISTING 3-WAY SWITCHES TO REMAIN AND IN USE.

REPLACE EXISTING SWITCH WITH NEW

NEW 3-WAY SWITCH TO CONTROL LIGHTS INDICATED.

TO SPARE 1P20A BREAKER IN EXISTING EMERGENCY PANEL "1E4A"

NEW CEILING MOUNTED OCCUPANCY

INSTALL NEW LIGHT

TO PREVENT

EXTEND ELECTRICAL CIRCUITING

CIRCUIT LIGHTS IN ROOM 101A WITH LIGHTS IN ROOM 101 AS INDICATED.

01 G.000 Cover Sheet-COVER
COVER
02 Gsheets_30x42 G.002 (1)
03 G.002 SITE PLAN G.001 (1)
04 AD.101 RCP Demo Plan-AD.101
AD.101
05 A.101 Reflected Ceiling Plan-A.101
A.101
FA-1 FIRE ALARM DEMO PLAN
FA-2 FIRE ALARM PLAN
FA-3 FIRE ALARM RISER MATRIX
FA-4 FIRE ALARM DETAILS
FA-5 FIRE ALARM TESTING
FS-1 FIRE SPRINKLER DEMO PLAN
FS-2 FIRE SPRINKLER PLAN
FS-3 FIRE SPRINKLER SCHEMATICS
FS-4 FIRE SPRINKLER DETAILS
FS-5 FIRE SPRINKLER TESTING
x-Electrical drawings_1-5-2022
E.001 ELECTRICAL LEGEND & LIGHT FIXTURE SCHEDULE
E.002 ELECTRICAL SITE PLAN
ED.101 DEMOLITION LIGHTING PLAN
E.101 REVISED LIGHTING PLAN

File details come from the government source that posted it. Updated .