This document provides details for a federal solicitation seeking renovation services for a fire suppression system at the Mike Monroney Aeronautical Center in Oklahoma City, Oklahoma. The scope of work includes upgrading the fire suppression, fire alarm system, ceiling system and lighting for the Powered Flight Training facility and must meet all requirements in the project drawings, specifications and direction from the Contracting Officer's Representative. The contractor must pre-order materials to be on-site prior to phasing start dates to accomplish the upgrades in each phase of work. All work will be overseen by the Department of Transportation Federal Aviation Administration Franchise Acquisition Services and must be completed at the specified facility location.

View the file

Other files

File Type Posted
98-0225PS600.pdf PDF
98-0225PS710.pdf PDF
Sidewalk Canopy _98-0225PL502.pdf PDF
98-0225PS002.pdf PDF
98-0225PS601.pdf PDF
98-0225PS700.pdf PDF
98-0225PS603.pdf PDF
98-0225PS003.pdf PDF
98-0225PS604.pdf PDF
98-0225PS100.pdf PDF
98-0225PS703.pdf PDF
98-0225PS301.pdf PDF
98-0225PS005.pdf PDF
98-0225PS702.pdf PDF
98-0225PS711.pdf PDF
98-0225PS701.pdf PDF
Past Performance Survey.pdf PDF
98-0225PS602.pdf PDF
98-0225PS004.pdf PDF
6973GH-22-R-00075-0001.pdf PDF
98-0225PS300.pdf PDF
213000 FIRE PUMP ENCLOSURE.pdf PDF
SHEET FS-6 FIRE WATER PLAN.pdf PDF
Pre Bid RFIs with Responses.pdf PDF
Past Performance Survey.pdf PDF
Client Authorization Letter.pdf PDF
PTS Fire and Lighting Reno-20220107_Dwgs.pdf PDF
SF 25 Performance Bond.pdf PDF
Wage Rate Determination - 25 Feb 22.pdf PDF
6973GH-22-R-00075.pdf PDF
Contractors Release.pdf PDF
SF25A - Payment Bond.pdf PDF
SOW WO 20-004873 PTS Replace Fire Suppression 1-21-22.pdf PDF
Operational Controls.pdf PDF
Chapter_33-Construction Safety.pdf PDF
PTS Fire and Lighting Reno_220107_Specs.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

STRUCTURAL GENERAL NOTES

AutoCAD SHX Text S001

AutoCAD SHX Text

AutoCAD SHX Text

PC

AutoCAD SHX Text

BEY

AutoCAD SHX Text

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

AutoCAD SHX Text

FEDERAL AVIATION ADMINISTRATION

AutoCAD SHX Text

AUGUST 29, 2003

AutoCAD SHX Text 405/478-5353 www.atkinsbenham.com

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

WORK ORDER NO.

AutoCAD SHX Text

FACILITY MANAGEMENT

AutoCAD SHX Text 98-0225

AutoCAD SHX Text

OFFICE OF

AutoCAD SHX Text

ISSUED BY

AutoCAD SHX Text

AMP-400B

AutoCAD SHX Text

AMP-400-E-98-0225

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

PREPARED BY

AutoCAD SHX Text

ATKINS BENHAM, INC.

AutoCAD SHX Text

REVIEWED BY

AutoCAD SHX Text

REV

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DEPARTMENT OF TRANSPORTATION

AutoCAD SHX Text

9400 NORTH BROADWAY

AutoCAD SHX Text

OKLAHOMA CITY, OKLAHOMA

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

JON BERKMAN

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

APP'D

AutoCAD SHX Text

CHECK

AutoCAD SHX Text

SUPPORT FACILITY

AutoCAD SHX Text

POWER TRAINING AND

AutoCAD SHX Text

AutoCAD SHX Text 8/29/03

AutoCAD SHX Text

ISSUE FOR BID

AutoCAD SHX Text %%uD. MASONRY

AutoCAD SHX Text ALL MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530.1(1999), "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES." DESIGN IS BASED ON ALL MASONRY RECEIVING FULL FIELD INSPECTION.

AutoCAD SHX Text PROVIDE CORNER BARS IN OUTSIDE FACE OF ALL FOUNDATION WALLS, STEM WALLS AND RETAINING WALLS EQUAL IN SIZE AND SPACING TO MAIN HORIZONTAL REINFORCING. EXTEND INSIDE FACE REINFORCING OF ALL WALLS TO OUTSIDE FACE AND BEND TO A STANDARD ACI 90 DEGREE HOOK.

AutoCAD SHX Text PROVIDE 2-#5 BARS EACH SIDE AND EACH FACE OF OPENINGS THROUGH WALLS OR SLABS UNLESS NOTED OTHERWISE. BARS SHALL EXTEND 24" PAST OPENING.

AutoCAD SHX Text SHOP DRAWINGS SHALL BE SUBMITTED WITH REINFORCING STEEL DETAILED IN ACCORDANCE WITH ACI 315-99.

AutoCAD SHX Text

FORMING AND EMBEDMENTS SHALL MEET THE FOLLOWING:

AutoCAD SHX Text SLABS-ON-GRADE SHALL HAVE CONSTRUCTION JOINTS, CONTROL JOINTS (SAWED JOINTS) AND ISOLATION JOINTS LOCATED AS SHOWN ON THE DRAWINGS.

AutoCAD SHX Text WHERE NECESSARY, VERTICAL CONSTRUCTION JOINTS SHALL BE LOCATED WITHIN THE CENTER ONE-THIRD OF THE SPAN. ALL JOINTS SHALL BE THOROUGHLY CLEANED AND PURPOSELY ROUGHENED TO 1/4" AMPLITUDE AND COATED WITH AN EPOXY TYPE BONDING AGENT PRIOR TO PLACING ADJACENT CONCRETE. JOINTS IN EXPOSED CONCRETE SHALL BE PROVIDED WITH A MAXIMUM SPACING OF 15 FEET.

AutoCAD SHX Text NO ALUMINUM SHALL BE EMBEDDED IN CONCRETE. PRIOR WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER IS REQUIRED FOR ANY CONDUIT OR PIPING TO BE EMBEDDED IN CONCRETE. WHERE ALLOWED CONDUITS AND PIPING EMBEDDED IN CONCRETE SHALL BE SPACED A MINIMUM OF FOUR DIAMETERS APART AND THE MAXIMUM OUTSIDE DIAMETER SHALL BE LESS THAN 30 PERCENT OF THE MEMBER THICKNESS PLACED BETWEEN LAYERS OF REINFORCING.

AutoCAD SHX Text CURING FOR CONCRETE SURFACES NOT IN CONTACT WITH FORMS, SHALL BE IN ACCORDANCE WITH THE PROCEDURES LISTED IN THE SPECIFICATIONS AND SHALL BE APPLIED IMMEDIATELY AFTER COMPLETION OF PLACEMENT AND FINISHING.

AutoCAD SHX Text

CONCRETE MASONRY UNITS (CMU) MATERIALS SHALL BE:

AutoCAD SHX Text ALL CONCRETE MASONRY UNITS (CMU) SHALL BE TWO CELL NORMAL WEIGHT AGGREGATE UNITS WITH A SPECIFIED MINIMUM COMPRESSIVE STRENGTH OF 2150 psi ON NET AREA, 1000 psi ON GROSS AREA AT 28 DAYS CONFORMING TO ASTM C90-00.

AutoCAD SHX Text SLABS-ON-GRADE TO RECEIVE FLOOR FINISHING SYSTEM SHALL BE FINISHED AND PREPARED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

AutoCAD SHX Text

FORMS OR TOOLED TO 1" RADIUS ON SLABS UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED 1" INSIDE

AutoCAD SHX Text SEISMIC USE GROUP I SPECTRAL RESPONSE COEFFICIENT SS = 0.371 S = 0.371 = 0.371 SPECTRAL RESPONSE COEFFICIENT S1 = 0.088 1 = 0.088 = 0.088 SITE CLASSIFICATION D MAX. SPECTRAL RESPONSE COEFFICIENT SDS = 0.20 DS = 0.20 = 0.20 MAX. SPECTRAL RESPONSE COEFFICIENT SD1 = 0.10 D1 = 0.10 = 0.10 SEISMIC DESIGN CATEGORY C METHOD OF DESIGN EQUIVALENT LATERAL FORCE PROCEDURE

AutoCAD SHX Text DESIGN BEARING PRESSURE (NET) IS 3,000 psf FOR FOUNDATIONS BEARING ON UNDISTURBED FIRM SOIL OR APPROVED ENGINEERED FILL MATERIAL. BEARING MATERIALS WILL BE VERIFIED BY A LICENSED GEOTECHNICAL ENGINEER.

AutoCAD SHX Text FOUNDATION REINFORCING SHALL BE SUPPORTED FROM ABOVE OR WITH 3" SBP (CONTINUOUS BOTTOM PLATE) AT 48" ON CENTER (MAX.) WHILE DEPOSITING CONCRETE IN FORMS.

AutoCAD SHX Text ALL FOUNDATION WALLS, STEM WALLS, RETAINING WALLS, PILASTERS AND PEDESTALS ARE DESIGNED WITH, AND SHALL HAVE, FORMED SIDES.

AutoCAD SHX Text MOISTURE CONTENT IN FOOTING EXCAVATIONS SHALL BE MAINTAINED UNTIL FOOTINGS ARE PLACED. FOOTINGS SHALL BE POURED AS SOON AS PRACTICAL AFTER EXCAVATIONS ARE COMPLETED.

AutoCAD SHX Text RETAINING WALLS AND FOUNDATION WALLS WHICH ARE TO RECEIVE FILL ON EACH SIDE OF THE WALL SHALL BE BACKFILLED SIMULTANEOUSLY ON EACH SIDE OF THE WALL IN APPROXIMATELY EQUAL LIFTS WITH A MAXIMUM DIFFERENTIAL HEIGHT OF 1'-0"

AutoCAD SHX Text E.

AutoCAD SHX Text D.

AutoCAD SHX Text C.

AutoCAD SHX Text B.

AutoCAD SHX Text 2.

AutoCAD SHX Text A.

AutoCAD SHX Text 1.

AutoCAD SHX Text

1. NO ALLOWANCE MADE FOR FUTURE EXTENSIONS OR ADDITIONS.

AutoCAD SHX Text FOUNDATIONS DESIGNED IN ACCORDANCE WITH RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL REPORT TITLED "SUBSURFACE EXPLORATION REPORT, PROPOSED (PDS BUILDING & ESS ADDITION" PREPARED FOR THIS PROJECT BY TERRACON, DATED MAY 20, 2003.

AutoCAD SHX Text %%uB. SOIL PREPARATION AND FOUNDATIONS:

AutoCAD SHX Text ALL EXCAVATION, FILL, COMPACTION AND GRADING OF THE SITE SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS AND THE RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL REPORT.

AutoCAD SHX Text LOAD COMBINATIONS ARE IN ACCORDANCE ASCE 7-98, "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" IN COMBINATION WITH "AISC SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS" (APRIL 15, 1997) AND ACI 318-99, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE."

AutoCAD SHX Text

SOIL SUPPORTED FOUNDATIONS-

AutoCAD SHX Text 3.

AutoCAD SHX Text A.

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text

LOAD COMBINATIONS-

AutoCAD SHX Text A.

AutoCAD SHX Text 5.

AutoCAD SHX Text 6.

AutoCAD SHX Text 5.

AutoCAD SHX Text D.

AutoCAD SHX Text C.

AutoCAD SHX Text B.

AutoCAD SHX Text A.

AutoCAD SHX Text E.

AutoCAD SHX Text 4.

AutoCAD SHX Text D.

AutoCAD SHX Text GRAVITY LOADS DETERMINED IN ACCORDANCE WITH ASCE 7-98, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES LOCATION UNIFORM CONCENTRATED LIVE LOAD LIVE LOAD* SLABS-ON-GRADE MECHANICAL ROOMS LABORATORY SPACES ROOF *2000 LB. CONCENTRATED LOAD APPLIED ON ANY 2.5 FT. x 2.5 FT. FLOOR AREA.

AutoCAD SHX Text SNOW LOADS DETERMINED IN ACCORDANCE WITH ASCE 7-98, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES. GROUND SNOW LOAD Pg = 10 PSF TERRAIN CATEGORY C (ASCE 6.5.3) EXPOSURE FACTOR Ce = 0.9 (ASCE TABLE 7-2, FULLY EXPOSED) THERMAL FACTOR Ct = 1.0 (ASCE TABLE 7-3, ALL STRUCTURES UNO) IMPORTANCE FACTOR I = 1.0 (ASCE TABLE 7-4, CATEGORY III) FLAT ROOF SNOW LOAD Pf = 6.3 (Pf = 0.7CeCtIPg) NO RAIN-ON-SNOW SURCHARGE LOAD IN ACCORDANCE WITH ASCE 7-98.

AutoCAD SHX Text

A. WIND LOAD LOADS DETERMINED IN ACCORDANCE WITH ASCE 7-98, MINIMUM

AutoCAD SHX Text

SEISMIC LOAD IN ACCORDANCE WITH 2000 INTERNATIONAL BUILDING CODE

AutoCAD SHX Text

I = 1.0 (CATEGORY II)

AutoCAD SHX Text 4.

AutoCAD SHX Text

LATERAL LOADS-

AutoCAD SHX Text

WIND IMPORTANCE FACTOR

AutoCAD SHX Text

DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.

AutoCAD SHX Text B.

AutoCAD SHX Text

BASIC WIND SPEED

AutoCAD SHX Text

WIND EXPOSURE

AutoCAD SHX Text V = 90 mph

AutoCAD SHX Text C

AutoCAD SHX Text 3.

AutoCAD SHX Text 200 psf

AutoCAD SHX Text 125 psf

AutoCAD SHX Text C.

AutoCAD SHX Text 2000 lb*

AutoCAD SHX Text BUILDING CODE - 2000 INTERNATIONAL BUILDING CODE WITH APPLICABLE OKAHOMA CITY, OKLAHOMA CODE SUPPLIMENTS.

AutoCAD SHX Text %%uA. DESIGN CRITERIA:

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text 100 psf

AutoCAD SHX Text A.

AutoCAD SHX Text PROVIDE GROUT FILLED BOND BEAM AT LOCATIONS INDICATED ON SECTIONS AND DETAILS AND AT THE TOP OF THE WALL OR PARAPET, AT THE BOTTOM OF THE WALL, AT TOP OF ALL OPENINGS, BELOW ALL OPENINGS, AT ALL BEARING LOCATIONS AND INTERMEDIATELY AT EVERY SIXTH COURSE (48" O.C.). BOND BEAMS SHALL BE REINFORCED AS FOLLOWS-

AutoCAD SHX Text WALL TYPE BOND BEAM REINF. (WxHxL)

AutoCAD SHX Text

REINFORCING SHALL MEET THE FOLLOWING LAP, SPLICE, AND EMBEDDMENT REQUIREMENTS:

AutoCAD SHX Text

LAP OR SPLICE

AutoCAD SHX Text

LENGTH IN WALL

AutoCAD SHX Text FOUNDATION DOWELS SHALL EXTEND A MINIMUM OF A LAP LENGTH INTO THE MASONRY WALLS UNLESS NOTED OTHERWISE.

AutoCAD SHX Text PROVIDE CORNER BARS AT ALL WALL CORNERS AND INTERSECTIONS, OF EQUAL NUMBER, BAR SIZE AND SPACING AS HORIZONTAL REINFORCING BARS UNLESS OTHERWISE NOTED (#4 MIN.).

AutoCAD SHX Text 5.

AutoCAD SHX Text #4

AutoCAD SHX Text #5

AutoCAD SHX Text #6

AutoCAD SHX Text #7

AutoCAD SHX Text #8

AutoCAD SHX Text

REINF. BAR SIZE

AutoCAD SHX Text

8X8X16 CMU BLOCK

AutoCAD SHX Text B.

AutoCAD SHX Text

DOWELS INTO FOUNDATION

AutoCAD SHX Text

STD. ACI HOOK

AutoCAD SHX Text 8"

AutoCAD SHX Text 10"

AutoCAD SHX Text 12"

AutoCAD SHX Text 14"

AutoCAD SHX Text 16"

AutoCAD SHX Text 24"

AutoCAD SHX Text 35"

AutoCAD SHX Text 40"

AutoCAD SHX Text 25"

AutoCAD SHX Text 30"

AutoCAD SHX Text 17"

AutoCAD SHX Text 29"

AutoCAD SHX Text 35"

AutoCAD SHX Text 21"

AutoCAD SHX Text 25"

AutoCAD SHX Text

EMBEDMENT WITH

AutoCAD SHX Text

STRAIGHT EMBEDMENT

AutoCAD SHX Text 2 - #4

AutoCAD SHX Text

EACH END OF A WALL.

AutoCAD SHX Text ALL MORTAR SHALL BE TYPE "S" WITH A MINIMUM MORTAR COMPRESSIVE STRENGTH OF 1800 psi AT 28 DAYS CONFORMING TO ASTM C270. THE MINIMUM COMPRESSIVE STRENGTH (f'm) OF A PRISM ASSEMBLED OF CMU AND MORTAR SHALL BE 1500 psi ON THE NET AREA AT 28 DAYS.

AutoCAD SHX Text GROUT SHALL CONFORM TO ASTM A476 WITH 3/8" AGGREGATED WITH THE FOLLOWING REQUIREMENTS-

AutoCAD SHX Text

LOCATION MINIMUM F'C UNIT WEIGHTC UNIT WEIGHT UNIT WEIGHT

AutoCAD SHX Text

REINFORCING STEEL SHALL MEET THE REQUIREMENTS OF ASTM A615/A615M GRADE 60.

AutoCAD SHX Text PROVIDE VERTICAL REINFORCING (NORMAL REINFORCING) IN GROUT FILLED CELLS IN ALL WALLS AS FOLLOWS UNLESS OTHERWISE NOTED-

AutoCAD SHX Text CELLS CONTAINING STEEL SHALL BE FILLED SOLIDLY WITH GROUT. THERE SHALL BE A FOUNDATION DOWEL FOR EACH VERTICAL REINFORCING BAR (NORMAL REINFORCING).

AutoCAD SHX Text PROVIDE AN ADDITIONAL VERTICAL REINFORCING BAR WITH FOUNDATION DOWEL IN GROUT FILLED CELL, OF SAME SIZE AND LENGTH AS THE NORMAL REINFORCING BAR, AT THE FOLLOWING LOCATIONS:

AutoCAD SHX Text

EACH SIDE OF A CONTROL OR ISOLATION JOINT.

AutoCAD SHX Text

INTERSECTION OF EXTERIOR WALLS.

AutoCAD SHX Text

EACH SIDE OF WALL OPENING.

AutoCAD SHX Text

EACH BEAM BEARING LOCATION.

AutoCAD SHX Text

HORIZONTAL WALL REINFORCING-

AutoCAD SHX Text

WALL TYPE REINF. IN

AutoCAD SHX Text

CMU GROUT

AutoCAD SHX Text 5.

AutoCAD SHX Text 4.

AutoCAD SHX Text 4.

AutoCAD SHX Text 3.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text B.

AutoCAD SHX Text

8" CMU

AutoCAD SHX Text

VERTICAL REINFORCING-

AutoCAD SHX Text 3.

AutoCAD SHX Text A.

AutoCAD SHX Text D.

AutoCAD SHX Text

%%UGENERAL STRUCTURAL NOTES

AutoCAD SHX Text C.

AutoCAD SHX Text B.

AutoCAD SHX Text 2000 psi

AutoCAD SHX Text

150 PCF

AutoCAD SHX Text

FILLED CELLS SPACING (INCHES)

AutoCAD SHX Text #4

AutoCAD SHX Text

AutoCAD SHX Text

MAXIMUM

AutoCAD SHX Text

LOCATION CLEAR COVER CLEAR COVER CLEAR COVER (IN.)

AutoCAD SHX Text REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615 GRADE 60. WELDING OF REINFORCING IS PROHIBITED.

AutoCAD SHX Text

CONCRETE REINFORCING SHALL MEET THE FOLLOWING:

AutoCAD SHX Text ALL REINFORCING SHALL BE CONTINUOUS. CONTINUOUS BARS SHALL LAP IN ACCORDANCE WITH ACI 318-99, UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

INTERIOR SLAB-ON-GRADE (COVER FROM TOP OF SLAB)

AutoCAD SHX Text

EXPOSED TO EARTH OR WEATHER #5 AND SMALLER

AutoCAD SHX Text

EXPOSED TO EARTH OR WEATHER #6 AND LARGER

AutoCAD SHX Text B.

AutoCAD SHX Text

CAST AGAINST EARTH

AutoCAD SHX Text 3.

AutoCAD SHX Text A.

AutoCAD SHX Text 1 1/2

AutoCAD SHX Text 1 1/2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LOCATION MINIMUM F'C UNIT WEIGHTC UNIT WEIGHT UNIT WEIGHT

AutoCAD SHX Text

28 DAY CONCRETE COMPRESSIVE STRENGTHS-

AutoCAD SHX Text

THE CONCRETE REQUIREMENTS ARE -

AutoCAD SHX Text

ALL STRUCTURAL CONCRETE DESIGNED IN ACCORDANCE WITH ACI 318-99.

AutoCAD SHX Text %%uC. CAST IN PLACE CONCRETE:

AutoCAD SHX Text CONCRETE CLEAR COVER OVER REINFORCING SHALL BE IN ACCORDANCE WITH ACI 318-99, LISTED BELOW, UNLESS OTHERWISE NOTED:

AutoCAD SHX Text

RETAINING WALLS

AutoCAD SHX Text

EXTERIOR SLAB-ON-GRADE

AutoCAD SHX Text

INTERIOR SLAB-ON-GRADE

AutoCAD SHX Text B.

AutoCAD SHX Text

FOUNDATION WALLS

AutoCAD SHX Text

FOUNDATIONS

AutoCAD SHX Text 2.

AutoCAD SHX Text A.

AutoCAD SHX Text 1.

AutoCAD SHX Text 4000 psi

AutoCAD SHX Text 4000 psi

AutoCAD SHX Text 4000 psi

AutoCAD SHX Text 3000 psi

AutoCAD SHX Text 4000 psi

AutoCAD SHX Text

150 PCF

AutoCAD SHX Text

150 PCF

AutoCAD SHX Text

150 PCF

AutoCAD SHX Text

150 PCF

AutoCAD SHX Text

150 PCF

AutoCAD SHX Text STEEL FRAMING CONNECTIONS SHALL BE TIGHTENED AND COLUMNS SHALL BE LEVELED AND GROUTED IN PLACE BEFORE DECKING IS ATTACHED TO FRAMING.

AutoCAD SHX Text ALL WELDING SHALL BE IN ACCORDANCE WITH THE AWS D1.1 WELDING CODE, LATEST EDITION. ALL WELDS SHALL USE E70XX ELECTRODES.

AutoCAD SHX Text CONNECTION BOLTS SHOWN IN DRAWINGS SHALL BE 3/4" DIA. A325 BEARING TYPE "N", UNLESS OTHERWISE NOTED.

AutoCAD SHX Text NO HOLES SHALL BE CUT THRU STEEL BEAMS IN FIELD UNLESS APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD.

AutoCAD SHX Text

STEEL JOISTS MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE.

AutoCAD SHX Text STEEL JOISTS SHALL BE FIELD WELDED OR BOLTED TO SUPPORTING MEMBERS AS INDICATED ON THE DRAWING EXCEPT PROVIDE BOLTED CONNECTIONS WHERE COLUMNS ARE NOT FRAMED IN TWO DIRECTIONS OR UNLESS OTHERWISE NOTED.

AutoCAD SHX Text ALL JOIST BRIDGING SHALL BE PERMANENTLY INSTALLED BEFORE CONSTRUCTION LOADS ARE APPLIED. EACH LINE OF BRIDGING SHALL BE ANCHORED AT ENDS TO WALLS OR BEAMS.

AutoCAD SHX Text TOP AND BOTTOM JOIST CHORDS ARE NOT DESIGNED FOR CONCENTRATED LOADS. PLACE LOADS AT PANEL JOINTS OR FIELD WELD L2x2x3/16" AT WEB MEMBER BETWEEN TOP AND BOTTOM CHORDS FROM POINT OF LOAD TO NEAREST PANEL POINT ON OPPOSITE CHORD. REFER TO DETAIL 11/S004.

AutoCAD SHX Text

STEEL ROOF DECKS SHALL COMPLY WITH THE STEEL DECK INSTITUTE REQUIREMENTS.

AutoCAD SHX Text

15. STRUCTURAL STEEL, STEEL JOISTS SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE

AutoCAD SHX Text REQUIREMENTS OF THE CURRENT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION STEEL ERECTION

AutoCAD SHX Text

29 CFR, SUBPART R.

AutoCAD SHX Text STEEL JOISTS SHALL MEET THE LATEST JOINT AISC/STEEL JOIST INSTITUTE SPECIFICATIONS.

AutoCAD SHX Text BOLTED DIAGONAL BRIDGING IF SHOWN ON PLANS, SHALL BE BOLTED AT THE INTERSECTION OF THE TWO ANGLES BETWEEN JOISTS.

AutoCAD SHX Text ALL HANGERS SUPPORTING MECHANICAL EQUIPMENT, ETC., FROM THE CHORD OF STEEL JOISTS SHALL BE LOCATED AT PANEL POINTS OF THE JOIST. WHERE HANGERS ARE NOT LOCATED AT PANEL POINTS, THE JOIST SHALL BE REINFORCED WITH ANGELS BETWEEN THE PANEL POINTS AS SHOWN ON DETAIL 11/S004.

AutoCAD SHX Text STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE, STANDARDS AND AISC SPECIFICATIONS, NINTH EDITION.

AutoCAD SHX Text STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS UNLESS OTHERWISE NOTED ON THE DRAWINGS:

AutoCAD SHX Text ALL BOLTED CONNECTIONS REQUIRING SLIP CRITICAL TYPE PRETENSIONED BOLTS WILL BE INDICATED AS (S.C.). DIRECT TENSION INDICATORS (DTI) WASHERS SHALL NOT BE USED. TENSION CONTROL BOLTS MAY BE USED.

AutoCAD SHX Text ALL CONNECTIONS NOT DETAILED OR OTHERWISE NOTED SHALL BE DESIGNED BY THE FABRICATOR. SHOP DRAWINGS AND CONNECTION CALCULATIONS SHALL BE SUBMITTED BEARING THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF OKLAHOMA. NON-COMPOSITE BEAMS SHEAR CONNECTIONS SHALL BE STANDARD AISC CONNECTIONS AND SHALL BE DESIGNED FOR THE SPAN USING THE "ALLOWABLE UNIFORM LOAD IN KIPS FOR BEAMS LATERALLY SUPPORTED" LOAD DIVIDED BY 2, FOUND IN SECTION 2, "ALLOWABLE LOADS ON BEAMS" OF THE AISC NINTH EDITION MANUAL OF STEEL CONSTRUCTION PLUS ANY AXIAL LOAD INDICATED ON THE DRAWINGS. DESIGN SHALL BE BASED ON BEARING TYPE BOLTED CONNECTIONS WITH BOLTS "SNUG TIGHT" PER AISC. WELDED TYPE CONNECTIONS SHALL BE APPROVED FOR USE PRIOR TO SUBMITTAL OF SHOP DRAWINGS.

AutoCAD SHX Text B.

AutoCAD SHX Text

STRUCTURAL STEEL CONNECTIONS-

AutoCAD SHX Text A.

AutoCAD SHX Text

STRUCTURAL TUBING

AutoCAD SHX Text

ANCHOR BOLTS

AutoCAD SHX Text

STRUCTURAL BOLTS

AutoCAD SHX Text 3.

AutoCAD SHX Text

STRUCTURAL WIDE FLANGE SHAPES (A572 GRADE 50 MAY BE SUBSTITUTED)

AutoCAD SHX Text

STRUCTURAL SHAPES AND PLATES

AutoCAD SHX Text

PIPE

AutoCAD SHX Text

%%UTYPE

AutoCAD SHX Text 2.

AutoCAD SHX Text A500

AutoCAD SHX Text A307

AutoCAD SHX Text A325

AutoCAD SHX Text B

AutoCAD SHX Text

46 KSI

AutoCAD SHX Text A992

AutoCAD SHX Text A36

AutoCAD SHX Text A53

AutoCAD SHX Text

B TYPE E

AutoCAD SHX Text

%%UASTM

AutoCAD SHX Text

%%UGRADE

AutoCAD SHX Text

50 KSI

AutoCAD SHX Text

36 KSI

AutoCAD SHX Text

35 KSI

AutoCAD SHX Text

%%UFY MIN.

AutoCAD SHX Text BOND BEAM REINFORCING SHALL BE CONTINUOUS THROUGHOUT, EXCEPT AT CONTROL AND ISOLATION JOINTS IT SHALL BE AS FOLLOWS:

AutoCAD SHX Text INTERMEDIATE BOND BEAM REINFORCING SHALL BE DISCONTINUOUS AT CONTROL JOINTS. REINFORCEMENT IN BOND BEAMS AT FLOOR AND ROOF DIAPHRAGM LEVELS SHALL BE CONTINUOUS THROUGH CONTROL JOINTS.

AutoCAD SHX Text

ALL BOND BEAM REINFORCING SHALL BE DISCONTINUOUS AT ISOLATION JOINTS.

AutoCAD SHX Text LOCATION AND DETAILS OF CONTROL AND ISOLATION JOINTS IN REINFORCED MASONRY SHALL BE AS SHOWN ON THE STRUCTURAL AND/OR ARCHITECTURAL DRAWINGS (REFER TO DETAIL 3 ON SHEET S-003). THE MAXIMUM SPACING OF CONTROL OR ISOLATION JOINTS SHALL BE AT A LENGTH TO HEIGHT RATIO OF 4 TO 1 OR 24' ON CENTER, WHICHEVER IS LESS.

AutoCAD SHX Text

MASONRY UNITS IN CONTACT WITH SOIL SHALL HAVE VOIDS FILLED WITH GROUT.

AutoCAD SHX Text LINTELS SHALL CONSIST OF GROUT FILLED BOND BEAMS AS SHOWN IN DETAIL 5/S002 UNLESS OTHERWISE NOTED.

AutoCAD SHX Text ALL LINTELS SHALL EXTEND NOT LESS THAN 40 BAR DIA. OR 24", WHICHEVER IS GREATER, BEYOND THE CORNER OF THE OPENING.

AutoCAD SHX Text VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO MAINTAIN A CLEAR UNOBSTRUCTED CONTINUOUS VERTICAL CELL NOT LESS THAN 2" x 3" IN PLAN DIMENSIONS.

AutoCAD SHX Text CELLS WHICH CONTAIN REINFORCING STEEL (VERTICAL CELLS, BOND BEAMS, LINTELS, AND PILASTERS) SHALL BE FILLED SOLIDLY WITH GROUT.

AutoCAD SHX Text VERTICAL AND HORIZONTAL BARS AROUND PERIMETER OF OPENINGS SHALL EXTEND NOT LESS THAN 40 BAR DIAMETERS OR 24", WHICHEVER IS LARGER, BEYOND THE CORNER OF THE OPENING.

AutoCAD SHX Text 10.

AutoCAD SHX Text %%uE. STRUCTURAL STEEL:

AutoCAD SHX Text 11.

AutoCAD SHX Text 12.

AutoCAD SHX Text 1.

AutoCAD SHX Text B.

AutoCAD SHX Text 9.

AutoCAD SHX Text A.

AutoCAD SHX Text 8.

AutoCAD SHX Text 7.

AutoCAD SHX Text 6.

AutoCAD SHX Text 11.

AutoCAD SHX Text 14.

AutoCAD SHX Text 13.

AutoCAD SHX Text 12.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 9.

AutoCAD SHX Text 10.

AutoCAD SHX Text 8.

AutoCAD SHX Text 7.

AutoCAD SHX Text 6.

AutoCAD SHX Text 4.

AutoCAD SHX Text 5.

AutoCAD SHX Text D.

AutoCAD SHX Text C.

AutoCAD SHX Text

AutoCAD SHX Text 20 psf

AutoCAD SHX Text

4. PROVIDE A FOUR INCH LAYER OF COMPACTED FINE AGGREGATE CAPILLARY WATER BARRIER OVER A

AutoCAD SHX Text 10 MIL VAPOR RETARDER SYSTEM OVER A ONE INCH LAYER OF COMPACTED FINE AGGREGATE CAPILLARY WATER

AutoCAD SHX Text BARRIER OVER A SIX INCH LAYER OF COMPACTED COARSE AGGREGATE CAPILLARY WATER BARRIER BETWEEN

AutoCAD SHX Text SLABS ON GRADE AND COMPACTED FILL SUB-BASE. FINE AGGREGATE MATERIAL SHALL BE AN UNWASHED

AutoCAD SHX Text

MINIMUM YIELD STRENGTH, FY = 50 KSI.

AutoCAD SHX Text

REQUIREMENTS OF ASTM A653. STRUCTURAL MEMBERS SHALL HAVE A

AutoCAD SHX Text

FROM CORROSION-RESISTANT STEEL, CORRESPONDING TO THE

AutoCAD SHX Text

2. ALL COLD-FORMED METAL FRAMING (CFMF) MEMBERS SHALL BE FORMED

AutoCAD SHX Text ACCORDANCE WITH TI 809-07 ANb 1996 AISI COLD-FORMED STEEL

AutoCAD SHX Text

1. COLD-FORMED METAL FRAMING (CFMF) HAS BEEN DESIGNED IN

AutoCAD SHX Text

SPECIFICATIONS AND SUPPLEMENTS.

AutoCAD SHX Text

WORK.

AutoCAD SHX Text

PLANS OR DETAILS WILL NOT BE PERMITTED AND WILL BE REJECTED

AutoCAD SHX Text

REPRODUCTION OF STRUCTURAL CONTRACT DOCUMENTS AS ERECTION

AutoCAD SHX Text

CONTRACTOR, SUBCONTRACTOR, SUPPLIER OR DISTRIBUTOR.

AutoCAD SHX Text

1. SHOP DRAWINGS SHALL BE ORIGINAL DRAWINGS, PREPARED BY

AutoCAD SHX Text

WITHOUT CHECKING.

AutoCAD SHX Text

OTHERWISE NOTED AND REINFORCED WITH #4 BARS ON 12" CENTERS

AutoCAD SHX Text

EACH WAY, 1 1/2" FROM TOP OF SLAB. WHEN THE PAD EXCEEDS 10" IN

AutoCAD SHX Text

AND BOTTOM. ANCHOR PAD TO SLAB WITH #4 DOWELS AT 24" ON CENTER

AutoCAD SHX Text

3. CONTRACTOR SHALL SUPPLY ALL ITEMS FOR ATTACHING MECHANICAL AND

AutoCAD SHX Text

ATTACHMENTS AND LOCATIONS OF THE EQUIPMENT WITH THE STRUCTURAL

AutoCAD SHX Text

4. SUBSTITUTION OF EXPANSION ANCHORS FOR EMBEDDED ANCHORS SHOWN

AutoCAD SHX Text

ON THE DRAWINGS WILL NOT BE PERMITTED UNLESS APPROVED BY THE

AutoCAD SHX Text

5. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING ADDITIONAL SERVICES

AutoCAD SHX Text

A. VERIFICATION OF ALL DIMENSIONS, ELEVATIONS, OPENING

AutoCAD SHX Text

TO EXISTING BUILDING.

AutoCAD SHX Text

SIZES, AND MECHANICAL EQUIPMENT WEIGHTS PRIOR TO STARTING

AutoCAD SHX Text

B. VERIFICATION OF ALL DIMENSIONS AND MEMBER SIZES RELATING

AutoCAD SHX Text

C. VERIFICATION OF ALL FLOOR DEPRESSIONS AND OFFSETS WITH

AutoCAD SHX Text

THICKNESS, REINFORCE WITH #4 BARS ON 12" CENTERS EACH WAY TOP

AutoCAD SHX Text

EACH WAY CAST OR EPOXIED INTO SUPPORTING SLAB. REFER TO 1/S003.

AutoCAD SHX Text

ELECTRICAL EQUIPMENT TO THE BUILDING STRUCTURE TO RESIST ALL

AutoCAD SHX Text

LOADS INCLUDING SEISMIC FORCES. ATTACHMENT SHALL BE MADE SO

AutoCAD SHX Text

AS NOT TO OVER STRESS STRUCTURAL MEMBERS. COORDINATE THE

AutoCAD SHX Text

SHOP DRAWINGS. REFER TO THE MECHANICAL AND ELECTRICAL

AutoCAD SHX Text

DRAWINGS FOR ADDITIONAL REQUIREMENTS.

AutoCAD SHX Text

CONTRACTING OFFICER IN ADVANCE.

AutoCAD SHX Text

2. UNLESS REQUIRED OR SHOWN OTHERWISE, CONCRETE PADS FOR MECHANICAL

AutoCAD SHX Text

AND ELECTRICAL EQUIPMENT ON FLOORS SHALL BE 4" HIGH UNLESS

AutoCAD SHX Text

DRAWINGS.

AutoCAD SHX Text

D. REMOVE ALL ABANDONED FOUNDATIONS, UTILITIES, PIPELINES,

AutoCAD SHX Text

ETC. THAT INTERFERE WITH NEW CONSTRUCTION.

AutoCAD SHX Text

E. REVIEW AND APPROVE ALL SHOP DRAWINGS PRIOR TO SUBMITTAL

AutoCAD SHX Text

CLEARLY NOTING CHANGES MADE WHICH DO NOT COMPLY WITH DESIGN

AutoCAD SHX Text

F. PROVIDE TEMPORARY BRACING AND SHORING AS REQUIRED FOR

AutoCAD SHX Text

STABILITY DURING CONSTRUCTION.

AutoCAD SHX Text

6. PLANS, SECTIONS, AND DETAILS ARE NOT TO BE SCALED FOR

AutoCAD SHX Text

DETERMINATION OF QUANTITIES, LENGTHS, OR FIT OF MATERIALS.

AutoCAD SHX Text

7. SEE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR

AutoCAD SHX Text

SPECIFICATIONS ARE COMPLEMENTARY, NEITHER IS MEANT TO STAND

AutoCAD SHX Text

ALONE FOR ANY PORTION OF THE WORK DESCRIBED HEREIN. ANY

AutoCAD SHX Text

CONFLICT BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED

AutoCAD SHX Text

9. FIRST FLOOR INTERIOR SLAB ON GRADE SHALL NOT BE POURED UNTIL

AutoCAD SHX Text

10. SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH THE

AutoCAD SHX Text

ROOF IS IN PLACE.

AutoCAD SHX Text

SIZE AND LOCATION OF ALL OPENINGS, SLEEVES, CURBS, PADS,

AutoCAD SHX Text

INSERTS, ETC. NOT SHOWN ON STRUCTURAL DRAWINGS. BEFORE

AutoCAD SHX Text

FABRICATION OF MATERIALS, COORDINATE WITH MECHANICAL AND

AutoCAD SHX Text

ELECTRICAL EQUIPMENT REQUIREMENTS.

AutoCAD SHX Text

8. CONSTRUCTION DOCUMENTS CONSIST OF THESE DRAWINGS AND A

AutoCAD SHX Text

SEPARATE BOOK OF SPECIFICATIONS. THE DRAWINGS AND

AutoCAD SHX Text

IMMEDIATELY TO THE CONTRACTING OFFICER.

AutoCAD SHX Text

REQUIREMENTS OF THE BUILDING CODE.

AutoCAD SHX Text

ARCHITECTURAL DRAWINGS.

AutoCAD SHX Text

%%UF. COLD-FORMED METAL FRAMING (CFMF):

AutoCAD SHX Text

%%UG. MISCELLANEOUS:

AutoCAD SHX Text

#10 PER ASTM D448.

AutoCAD SHX Text

5. REFER TO ARCH. SERIES DRAWINGS AND PROVIDE PERIMETER FOUNDATION INSULATION.

AutoCAD SHX Text NATIVE SOILS SHALL BE OVEREXCAVATED TO A MINIMUM DEPTH OF 1'-6" IMMEDIATELY BELOW THE FINISH SUBGRADE ELEVATION AND REPLACED WITH A COMPACTED LOW VOLUME CHANGE SOIL IN ACCORDANCE WITH GEOTECHNICAL REPORT.

AutoCAD SHX Text F.

AutoCAD SHX Text 13.

AutoCAD SHX Text

COORDINATE W/ARCH. SERIES DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.

AutoCAD SHX Text 14.

AutoCAD SHX Text

STEEL ROOF DECK SHALL BE 1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

" DEEP, 18 GA., WIDE RIB METAL DECKING, GALVANIZED. DECKING

AutoCAD SHX Text SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI, A MINIMUM I OF 0.292 IN. /FT., A MINIMUM

AutoCAD SHX Text Sp OF 0.318 IN. /FT., AND A MINIMUM Sn OF 0.327 IN. /FT. DECKING SHALL RECEIVE A

AutoCAD SHX Text GALVANIZED FINISH PER SPECIFICATION. DECKING SHALL BE CONTINUOUS OVER A MINIMUM OF

AutoCAD SHX Text THREE SUPPORTS. DECKING SHALL BE ATTACHED TO SUPPORTING MEMBERS AND ADJACENT PANELS

AutoCAD SHX Text

AS FOLLOWS:

AutoCAD SHX Text

NO. OF END SUPPORT (PERPENDICULAR AND PARALLEL 5 7

AutoCAD SHX Text

5/8" DIAMETER PUDDLE WELDS

AutoCAD SHX Text

#10 TEK SCREW SIDELAP CONNECTION EQUALLY SPACED 4" O.C. 4" O.C.

AutoCAD SHX Text

BETWEEN SUPPORTS

AutoCAD SHX Text

%%U24" PANEL%%U %%U36" PANEL

AutoCAD SHX Text

6. ADDITIONAL LOADS:

AutoCAD SHX Text ROOF STRUCTURE HAS BEEN DESIGNED FOR AN EQUIVALENT SURCHARGE LOAD OF 30 PLF IN THE

AutoCAD SHX Text LONGITUDINAL DIRECTION AT A MINIMUM SPACING OF 3'-0" O.C. FOR THE ADDITION OF FUTURE

AutoCAD SHX Text

ELECTRICAL CABLE AND CONDUIT IN THE HIGH BAY ROOF ABOVE ROOMS 101, 102 AND 103.