Recovery design/build waterline, rickenbacker army enclave, columbus, ohio

Award Notice Posted

Solicitation number
W91364-10-R-2000
Agency
Awarded
to The Rudolph / Libbe Companies Inc
Set-aside
No set-aside

Opportunity facts

Contract number
W91364-05-D-0014-0043 Federal contract award
NAICS code
236210 Industrial Building Construction
PSC
Not on record
Place of performance
Rickenbacker Army Enclave Columbus, Ohio 43217, United States

Notice details come from SAM.gov. Updated .

Notice text

 RECOVERY - PER FAR 5.7 THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY; THEREFORE FAR 5.203 DOES NOT APPLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER THE FOLLOWING CURRENT OHIO NATIONAL GUARD MULTIPLE AWARD TASK ORDER CONTRACTS: W91364-05-D-0001, Toltest INC W91364-05-D-0002, Syska Hennessy Group, W91364-05-D-0006, Rock Industries INC W91364-05-D-0008, McTech Corp W91364-05-D-0009, Four Seasons Environmental, Inc W91364-05-D-0010, Sherrick/Woolpert, INC (Joint Venture) W91364-05-D-0011, Northwind Engineering, LLC W91364-05-D-0012, Q.B.S., INC W91364-05-D-0014, Rudolph/Libbe Companies INC W91364-05-D-0015, LDV, INC W91364-05-D-0016, Braun Enterprises, INC W91364-05-D-0017, W91364-05-D-0020, Versar Inc W91364-05-D-0021, Lusk Mechanical Contractors INC.   The design, permitting, site preparation, construction of the system will consist of the following tasks: Separate the existing RAE water lines from the old loop system and abandon them in place, ensuring minimal disruption of service to all customers. Replace the abandoned loop system with approximately 6,000' of new water line. The new line must be capable of providing clean, palatable water to all RAE customers. In addition to meeting the RAE's domestic needs, the water line must also supply enough water to meet the enclave's industrial and fire protection needs. The system must be capable of delivering and sustaining approximately 125psi to all customers. All lateral, service branch feeders to RAE facilities must be replaced. The new system must have a master meter. Each serviced facility must have a smart reader that can be remotely read by the City of Columbus. Obtain all Permits.  Provide As-Built Drawings, Equipment Warranties, Maintenance Manuals, and all other supporting documentation associated with new RAE water distribution system. Restore the work site to pre-existing work conditions, i.e. repair/replace all asphalt, concrete, grass, etc.

Files

File Type Posted
Fig. 7.1.pdf PDF
Divider Sheets.doc DOC document
CHAPTER 6 FIREPROTECTION TABLES TABLE 6.7.pdf PDF
CHAPTER 7 SANITARY TABLES TABLE 7.3.pdf PDF
Appendix A - ANG.pdf PDF
Army CHAPTER 7 SANITARY TABLES TABLE 7.2.pdf PDF
Table of Contents.pdf PDF
CHAPTER 6 WATER SYSTEM TABLES TABLE 6.3.pdf PDF
CHAPTER 6 WATER SYSTEM TABLES TABLE 6.5.pdf PDF
Army report_final.pdf PDF
CHAPTER 6 FIREPROTECTION TABLES TABLE 6.8pdf.pdf PDF
CHAPTER 4 POPULATION TABLES.xls XLS spreadsheet
ANG Report-final.pdf PDF
CHAPTER 6 WATER SYSTEM TABLES TABLE 6.1.pdf PDF
CHAPTER 7 SANITARY TABLES TABLE 7.4.pdf PDF
CHAPTER 6 FIREPROTECTION TABLES.xls XLS spreadsheet
Army Table of Contents.pdf PDF
MATOC DB Offering Instruction and Evaluation.doc DOC document
CHAPTER 6 FIREPROTECTION TABLES TABLE 6.10.pdf PDF
CHAPTER 7 SANITARY TABLES.xls XLS spreadsheet
Report Cover.doc DOC document
utility site drawing.TIF TIF image
C100-C105.dwg DWG drawing
CHAPTER 7 SANITARY TABLES TABLE 7.2.pdf PDF
rae_water_sow.doc DOC document
Army Fig. 6.1.pdf PDF
Fig. 3.1.pdf PDF
CHAPTER 6 WATER SYSTEM TABLES TABLE 6.4.pdf PDF
CHAPTER 6 WATER SYSTEM TABLES.xls XLS spreadsheet
CHAPTER 7 SANITARY TABLES TABLE 7.5.pdf PDF
Army 20-yr LIFE CYCLE.xls XLS spreadsheet
Army CHAPTER 7 SANITARY TABLES TABLE 7.1.pdf PDF
CHAPTER 6 FIREPROTECTION TABLES TABLE 6.6.pdf PDF
CHAPTER 6 WATER SYSTEM TABLES TABLE 6.2.pdf PDF
EXHIBIT ABC.doc DOC document
20-yr LIFE CYCLE.xls XLS spreadsheet
Army Fig. 3.1.pdf PDF
Fig. 6.2.pdf PDF
CHAPTER 6 FIREPROTECTION TABLES TABLE 6.9.pdf PDF
Report Cover.pdf PDF
Army CHAPTER 6 WATER SYSTEM TABLES-BB.xls XLS spreadsheet
Responses to draft report Review Comments .pdf PDF
Army CHAPTER 6 WATER SYSTEM TABLES-TABLE 6.1.pdf PDF
Fig. 6.1.pdf PDF
Army CHAPTER 6 FIREPROTECTION TABLES TABLE 6.4.pdf PDF
CHAPTER 7 SANITARY TABLES TABLE 7.1.pdf PDF
EXHIBIT E.doc DOC document
Exhibit D.doc DOC document
Army CHAPTER 6 FIREPROTECTION TABLES-BB.xls XLS spreadsheet
Appendix A-Army.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors