The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is procuring comprehensive electrical system inspection, testing, and maintenance services for the Brooklyn VA Medical Center and St. Albans Community Living Center in New York. The contract requires contractors to perform detailed electrical system testing in compliance with NFPA and Joint Commission standards, including circuit breaker maintenance, switchgear testing, infrared scanning, and annual load bank testing for fifteen generators across multiple buildings. Qualified contractors must demonstrate at least five years of continuous experience in electrical maintenance within healthcare or equivalent industrial settings and possess NETA or NICET certifications. The evaluation will consider technical capability statements, pricing details, past performance information, and required representations and certifications. The original proposal deadline was November 12, 2025, which was extended to November 17, 2025, and subsequently to November 18, 2025, at 4:30 PM EST, with the question submission period closing on November 10, 2025 at 12:00 PM.

This solicitation is designated as a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB), and the estimated contract value is up to $19 million. The base period runs from December 1, 2025, through November 30, 2026, with four one-year option periods extending through November 30, 2030. The scope of work encompasses comprehensive maintenance of electrical infrastructure including switchgear, transformers, circuit breakers, automatic transfer switches, and fifteen generators located across multiple buildings at both facilities. Annual maintenance activities will be conducted consecutively within an eight-weekend period per campus, with contractors responsible for oil changes per manufacturer specifications, temporary power accommodations, oil containment, and off-site disposal. The contract will be administered by the Department of Veterans Affairs Network Contracting Office located in Buffalo, New York, with work performed at the Brooklyn VA Medical Center at 800 Poly Place and the St. Albans Community Living Center at 179-00 Linden Boulevard in New York.

Notice text

Electrical System Inspection, Testing and Maintenance at the Brooklyn VA Medical Center and St Albans Community Living Center

Files

File Type Posted
Brooklyn Breakers .docx DOCX document
36C24226Q0023 0003.docx DOCX document
36C24226Q0023 0002.docx DOCX document
36C24226Q0023 0001.docx DOCX document
Attachment B.docx DOCX document
Attachment A.docx DOCX document
WD 2015-4187 Rev. 33.pdf PDF
36C24226Q0023_1.docx DOCX document

Notice history

Notice Type Posted
J059--Electrical System Inspection, Testing and Maintenance Award Award Notice
This notice Latest solicitation Solicitation
J059--BK/SA Electrical ITM Service Pre-Solicitation
J059--Electrical ITM Service (Base 4) Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J061--SOURCES SOUGHT NOTICE - Triennial Electrical Inspection Testing and Maintenance Services Requirement - Louis A Johnson VA Medical Center 36C24527Q0039 Department of Veterans Affairs Louis A Johnson VA Medical Center Clarksburg, West Virginia 26301, United States · NAICS 238210 Veterans Integrated Service Network 5 No set-aside
J061--triennial electrical maintenance - amendment 4 POP: 12/01/2026 - 11/30/2027 plus 4 option years Slvhcs New Orleans, Louisiana 70119, United States · NAICS 238210 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
J061--electrical testing (solicitation) Hampton, Virginia 23667, United States · NAICS 238210 Veterans Integrated Service Network 6 Total Small Business
657A5-26-111, Triennial Electrical Testing Marion, Illinois 62959, United States · NAICS 238210 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business Sole Source
J061--Triennial Circuit Breaker and Feeder Testing NAICS 238210 Veterans Integrated Service Network 21 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors