Attachment A.docx
DOCX document 23 KB Posted
- Attached to
- J059--BK/SA Electrical ITM Service Federal contract opportunity
- Solicitation number
- 36C24226Q0023
About this file
This document appears to be an attachment (Attachment A.docx) detailing electrical system components and infrastructure for the Brooklyn VA Medical Center. The file comprehensively lists electrical distribution equipment across multiple buildings, including switchgear, transformers, panels, busways, transfer switches, and circuit breakers located in various building locations such as B-120, B-301, B-401, and the Chiller Plant.
The attachment corresponds to Solicitation Number 36C24226Q0023 for "Electrical ITM Service" issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2. The scope involves electrical system inspection, testing, and maintenance at the Brooklyn VA Medical Center and St. Albans Community Living Center. Specific testing requirements are noted for busways, including connection torque verification, exterior cleaning, and infrared scanning at connection points, with minimal additional testing mandated.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Brooklyn Breakers .docx | DOCX document | |
| 36C24226Q0023 0003.docx | DOCX document | |
| 36C24226Q0023 0002.docx | DOCX document | |
| 36C24226Q0023 0001.docx | DOCX document | |
| Attachment B.docx | DOCX document | |
| WD 2015-4187 Rev. 33.pdf | ||
| 36C24226Q0023_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Brooklyn
| Designation |
| Location |
| Drwg. |
| Solar Panels and associated Distribution System |
| Building 1 Roof |
| SWGR – A Busway |
| G-422 |
| E-304 |
| SWGR – B Busway |
| G-422 |
| E-304 |
| SWGR – A (15 CB; 2 Spare slots) |
| G-422 |
| E-304 |
| SWGR – B (18 CB; 2 Spare slots) |
| G-422 |
| E-304 |
| SB Panel |
| G-422 |
| SBL Panel |
| G-422 |
| Fire Pump Disconnect Switch (Infrared Only) |
| G-422 |
| E-304 |
| Fire Pump 125HP CB |
| G-672 |
| E1.01 |
| HDPE-1A |
| G-672 |
| E1.01 |
| HDPE-1B |
| G-672 |
| E1.01 |
| HDPE-1D |
| G-671 |
| E1.01 |
| HDP-1CA |
| G-672 |
| E1.01 |
| HDP-1CB |
| G-672 |
| E1.01 |
| SWGR- OPC Busway |
| G-672 |
| E1.01 |
| SWGR- OPC |
| G-672 |
| E1.01 |
| HDP-LSG |
| G-672 |
| E1.01 |
| EDP-A |
| G-672a |
| E1.01 |
| EDP-B |
| G-672a |
| E1.01 |
| ATS-1 |
| G-672a |
| E1.01 |
| ATS-2 |
| G-672 |
| E1.01 |
| ATS-3 |
| G-672a |
| E1.01 |
| ATS-4 |
| G-672a |
| E1.01 |
| ATS-5 |
| G-672a |
| E1.01 |
| ATS-6 |
| G-672a |
| E1.01 |
| ATS-7 |
| G-672a |
| E1.01 |
| ATS-8 (Fire Alarm Fuse Cutout) |
| G-672 |
| E1.01 |
| ATS-9 (Fire Pump) |
| G-672a |
| E1.01 |
| ATS-10 |
| G-672a |
| E1.01 |
| ATS-11 |
| G-672a |
| E1.01 |
| ATS-12 |
| G-672a |
| E1.01 |
| ATS-13 |
| G-672a |
| E1.01 |
| DB-A Panel |
| B-200A (A Closet) |
| Large Junction Box |
| B-200A (A Closet) |
| Federal Pacific Xfrmer 500 KVA |
| B-200A (A Closet) |
T4T500CSE
| A Panel |
| B-200A (A Closet) |
| Xfrmer #9T2309872 |
| B-619 |
| Xfrmer #9T23Q9871G15 |
| B-619 |
| Siemens Feeder D Panel |
| B-127 (D Closet) |
| DB-D Panel |
| B-127 (D Closet) |
| Xfrmer #T41500CSE |
| B-127 (D Closet) |
| Xfrmer – 500 KVA |
| B-124 |
| Feeder C Panel |
| B-124 (C Closet) |
| Sub C Panel |
| B-124 (C Closet) |
| DB-C Panel |
| B-124 (C Closet) |
| Federal Pacific 500KVA T4T500CSE |
| B-120 (B Closet) |
| Square D – 30 KVA |
| B-120 (B Closet) |
| Feeder B – PP (Siemens) |
| B-120 (B Closet) |
| Sub B Panel |
| B-120 (B Closet) |
| Square D 75kVA Xfrmr |
| B-120 (B Closet) |
| EDP Panel |
| B-120 (B Closet) |
| 480-B Panel |
| B-120 (B Closet) |
| DB-B Panel |
| B-120 (B Closet) |
| Square D 75kVA Disconnect Switch |
| B-120 (B Closet) |
| ATS-1 |
| B-301 |
| ATS-2 |
| B-301 |
| ATS-3 |
| B-301 |
| ATS-4 |
| B-301 |
| EDP Panel |
| B-301 |
| LED PB |
| B-301 |
| Xfrmr 112.5kVA T4T112CSE |
| B-301 |
| HEDPB |
| B-301 |
| Xfrmr 150kVA T4T150CSE |
| B-301 |
| Xfrmr 150kVA Disconnect |
| B-301 |
| Siemens PanelBoards |
| B-401 |
| Switchboard DP-BB |
| B-401 |
| TI-I 300KVA Xfrmer |
| B-401 |
| 75kVA 9T23B3874G03 |
| B-401 |
| 208V SWBD |
| B-401 |
| Switchboard DP-B |
| B-401 |
| Switchboard DP-A |
| B-401 |
| DP-B (Siemens) |
| B-401 |
| PP-B Panel |
| B-401 |
| Junction Box 277/480V |
| B-401 |
| Junction Bx (by exit door) |
| B-401 |
| Fire Pump Power Transfer Switch |
| B-400 (Cage) |
| 3000A Main Circuit Breaker for Generator |
| Building 4- Gen rm |
| ATS-G1 |
| Building 4- Gen rm |
| Safety Switch |
| Building 4- Gen rm |
| ATS Transfer Switch |
| Room 231 |
| MTS – 14 |
| Chiller Plant |
| 900 TON Carrier |
| Chiller Plant |
| 200Ton Chiller Disconnect Switch |
| Chiller Plant |
| GE Power Panelboards |
| Chiller Plant |
| Xfrmr #9T23Q9872 |
| Chiller Plant |
| 4-MCCE-2 |
| Chiller Plant |
| General Electric MCC |
| Chiller Plant |
| T4-O 300KVA Transformer T4T300CSE |
| Boiler Plant |
| Switchboard A&B |
| Boiler Plant |
| Switchboard L |
| Boiler Plant |
| Switchboard L-1 |
| Boiler Plant |
For Busways, check all connections for proper torque. Tighten where required. Clean exterior housing as needed. IR scan visible portions where busway enters equipment and at connection points. No other testing required.