H312--RLRVAMC Fire Alarm Testing/Monitoring

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C25026Q0002
Agency
Veterans Integrated Service Network 10 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
561621 Security Systems Services (except Locksmiths)
PSC
H312 Inspection- Fire Control Equipment
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 is seeking comprehensive fire alarm testing and monitoring services for the Richard L. Roudebush Veterans Affairs Medical Center (RLRVAMC) in Indianapolis, Indiana. The procurement requires a contractor to provide annual and semi-annual inspections, testing, certification, and 24/7 UL-listed central station monitoring of complex fire alarm systems across two campus locations. Key requirements include technicians certified to NICET Level 2 or 3 with specific experience in Siemens XLSV and Honeywell Silent Knight fire alarm systems, compliance with NFPA 72 standards and Joint Commission requirements, and comprehensive electronic documentation submitted within 14 days of service completion. The contractor must perform disruptive testing after normal business hours and provide daily phone line testing using Plain Old Telephone Services (POTS), with current monitoring services provided by General Monitoring. The solicitation was posted on July 11, 2025, with proposals due by August 15, 2025.

This procurement is designated as a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside with a NAICS code of 561621 and size standard of $25 million. The contract structure includes a base year from October 15, 2025, to October 14, 2026, with four additional one-year option periods, potentially extending the total contract duration to five years. The scope encompasses extensive fire alarm system components including 149 tamper switches, 244 manual initiating devices, 821 smoke detectors, and 694 strobes/sirens/bells/horns across multiple buildings. Services will be performed at two locations: the main RLRVAMC campus at 1481 W. 10th Street and the Cold Springs Road Campus in Indianapolis, Indiana. General Monitoring is identified as the current incumbent providing monitoring services for the facility's fire alarm systems.

Notice text

RLRVAMC Fire Alarm Testing/Monitoring

Attachments

Files attached to this notice, newest first
File Type Posted
36C25026Q0002 0002.docx DOCX document
36C25026Q0002 0001.docx DOCX document
36C25026Q0002.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
H312--RLRVAMC Fire Alarm Testing/Monitoring Award Award Notice
H312--RLRVAMC Fire Alarm Testing/Monitoring This notice · Latest solicitation Solicitation
H312--RLRVAMC Fire Alarm Testing/Monitoring Original Pre-Solicitation