J063--Fire Alarm and Testing Inspection FY 2027 Services Procurement - 541 Engineering - VAMC CLEVELAND
Open Solicitation Posted
- Solicitation number
- 36C25027Q0033
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 541350 Building Inspection Services
- Place of performance
- Department of Veteran Affairs Louis Stokes VA Medical Center Cleveland, Ohio 44106, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 10, through VA Network Contracting Office 10, seeks fire alarm testing and inspection services for the Cleveland VA Medical Center, with quotations due December 8, 2026 at 12:00 PM ET. The procurement is set aside for Service-Disabled Veteran-Owned Small Businesses, and requests for information are due December 1, 2026 at 12:00 PM ET.
Place of performance is 10701 East Boulevard, Cleveland, Ohio 44106. The work covers the facility's Notifier fire alarm system across a 2-million-square-foot campus under NAICS 541350 (Building Inspection Services) and PSC J063, with a small business size standard of $11.5 million. The firm-fixed-price base period runs January 1, 2027 through December 31, 2027, with four one-year options through December 31, 2030.
Offerors must show at least five years of successful experience with Notifier systems of similar size and complexity during the seven years preceding the closing date, and must hold current Notifier dealer certification and programming capability. Contractors must provide Notifier parts and technical support access and CLSS Gateway report generation at no additional cost to the Government. Work must comply with NFPA 72 (2022 edition) and Joint Commission requirements and includes contractor-supplied scissor lifts for atrium smoke detector testing at 40-foot ceilings, water flow and tamper switch testing with operational valve activation, and weekend live pull-station testing. Submissions require a completed VAAR 852.219-75 Notice of Limitations on Subcontracting certification, which states that 50% of contract value cannot be subcontracted, along with SAM certifications.
Evaluation uses five factors: Technical Approach and Scheduling; Personnel and Safety Resources; Notifier System Capability; Relevant Experience and Past Performance; and Price. Non-price factors combined are weighted more heavily than price in a best-value award.
Notice text
2 versions
Update #2 · Latest ·
11/24/2026 - Removed duplicate combined solicitation document
Update #1 ·
42
Effective Date: 01/15/2026 Revision: 03
Opportunities Description
Combined Synopsis Solicitation Cleveland VAMC Fire Alarm Testing and Inspection
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Veterans Integrated Service Network 2 | No set-aside | |
| Northern California Area Office (NCAO) Fire Alarm | — | Service-Disabled Veteran-Owned Small Business | |
| J012--Fire Suppression System Maintenance and | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| Boise VAMC Fire Alarm System Maintenance | Veterans Integrated Service Network 20 | No set-aside | |
| Z1DA--Upgrade Fire Alarm System Construction 676-22-110 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities