J063--Fire Alarm and Testing Inspection FY 2027 Services Procurement - 541 Engineering - VAMC CLEVELAND

Open Solicitation Posted

Solicitation number
36C25027Q0033
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
541350 Building Inspection Services
Place of performance
Department of Veteran Affairs Louis Stokes VA Medical Center Cleveland, Ohio 44106, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 10, through VA Network Contracting Office 10, seeks fire alarm testing and inspection services for the Cleveland VA Medical Center, with quotations due December 8, 2026 at 12:00 PM ET. The procurement is set aside for Service-Disabled Veteran-Owned Small Businesses, and requests for information are due December 1, 2026 at 12:00 PM ET.

Place of performance is 10701 East Boulevard, Cleveland, Ohio 44106. The work covers the facility's Notifier fire alarm system across a 2-million-square-foot campus under NAICS 541350 (Building Inspection Services) and PSC J063, with a small business size standard of $11.5 million. The firm-fixed-price base period runs January 1, 2027 through December 31, 2027, with four one-year options through December 31, 2030.

Offerors must show at least five years of successful experience with Notifier systems of similar size and complexity during the seven years preceding the closing date, and must hold current Notifier dealer certification and programming capability. Contractors must provide Notifier parts and technical support access and CLSS Gateway report generation at no additional cost to the Government. Work must comply with NFPA 72 (2022 edition) and Joint Commission requirements and includes contractor-supplied scissor lifts for atrium smoke detector testing at 40-foot ceilings, water flow and tamper switch testing with operational valve activation, and weekend live pull-station testing. Submissions require a completed VAAR 852.219-75 Notice of Limitations on Subcontracting certification, which states that 50% of contract value cannot be subcontracted, along with SAM certifications.

Evaluation uses five factors: Technical Approach and Scheduling; Personnel and Safety Resources; Notifier System Capability; Relevant Experience and Past Performance; and Price. Non-price factors combined are weighted more heavily than price in a best-value award.

Notice text

2 versions

Update #2 · Latest ·

11/24/2026 - Removed duplicate combined solicitation document

Update #1 ·

42

Effective Date: 01/15/2026 Revision: 03

Opportunities Description

Combined Synopsis Solicitation Cleveland VAMC Fire Alarm Testing and Inspection

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC NAICS 561621 Veterans Integrated Service Network 2 No set-aside
Northern California Area Office (NCAO) Fire Alarm NAICS 561621 — Service-Disabled Veteran-Owned Small Business
J012--Fire Suppression System Maintenance and Richard L. Roudebush Vamc 1481 W 10th Street Indianapolis, Indiana 46202, United States · NAICS 811310 Veterans Integrated Service Network 10 Service-Disabled Veteran-Owned Small Business
Boise VAMC Fire Alarm System Maintenance Boise, Idaho 83702, United States · NAICS 561621 Veterans Integrated Service Network 20 No set-aside
Z1DA--Upgrade Fire Alarm System Construction 676-22-110 Tomah, Wisconsin 54660, United States · NAICS 238210 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors