Design-build (DB), P-1476U new fire apparatus BAY cheatham annex, naval weapons station yorktown, virginia
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- N40085-26-R-0131
- Agency
-
Naval Facilities Engineering Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Yorktown, Virginia, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Navy Naval Facilities Engineering Command seeks design-build services for a new fire apparatus bay at Cheatham Annex, Naval Weapons Station Yorktown, Virginia, with proposals due June 9, 2026. This procurement is restricted to holders of the Design-Build/Design-Bid-Build (DB/DBB) Multiple Award Construction Contract (MACC) under contract numbers N4008524D0030-38 and 0069 covering general construction in the Hampton Roads, Virginia area—no open competition.
Place of performance is Yorktown, Virginia. The facility comprises approximately 3,136 gross square feet (56' × 56' footprint) with two medium apparatus bays accommodating a Quint 25 Single Rear Axle fire apparatus (maximum GAWR 33,500 lbs), plus supporting spaces including protective equipment laundry with NFPA 1850-compliant extractors and drying cabinets, PPE gear storage with 11 lockers, decontamination room with eye/face wash and drench shower per UFC 4-730-10 Table 4-1, ADA-compliant unisex restroom, and mechanical room. The existing fire station must remain fully operational 24/7 during construction.
Design must be 100% electric with no natural gas or propane, demonstrate 30% energy reduction below baseline per UFC 1-200-02 and FC 1-300-09N, and employ mandatory Building Information Modeling per Section 01 33 10.05 20. HVAC systems must include thermostatically controlled electric infrared heaters maintaining minimum temperature above freezing; emergency fixtures must maintain 85°F water temperature. The prime contractor must achieve CMMC Level 1 by proposal submission. Construction completion is 800 days after award. The base bid covers primary facility construction, supporting facilities, excavation and disposal of 1,500 tons of impacted soil (including PFAS contamination), treatment of 25,000 gallons of contaminated dewatering effluent, undercut and replacement of 1,500 cubic yards of geotechnically unsuitable subgrade, and demolition of buried concrete and debris (75 tons). Three optional line items include two additional overhead doors, CMU exterior wall backup system, and Furniture, Fixtures, and Equipment (Government-estimated at $28,836 plus contractor handling fee not to exceed 5%). Award evaluation will be based on total proposed price for all line items. Contract POC is Chamel Adams (chamel.r.adams.civ@us.navy.mil). NAICS 236220; PSC Y1JZ.
Notice text
Please note: this solicitation and all applicable attachments are restricted to MACC holders (N4008524D0030-38, 0069) under the Design-Build (DB)/Design-Bid-Build (DBB), Indefinite Delivery/Indefinite Quantity (ID/IQ) Multiple Award Construction Contract (MACC) General Construction in the Hampton Roads, Virginia Area of Responsibility.
Files
Show all 16
Notice history
| Notice | Type | Posted |
|---|---|---|
| Design-build (DB), P-1476U new fire apparatus BAY cheatham annex, naval weapons station yorktown, virginia | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Replace radiant heating system and exhaust fan, bldg. 362 DAM neck annex, virginia beach, VA | Naval Facilities Engineering Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity