The Department of the Navy's Naval Facilities Engineering Command seeks design-build proposals to replace the radiant heating system and exhaust fan in Building 362, Dam Neck Annex, Virginia Beach, Virginia, with pre-proposal questions due December 2, 2026 and proposals due December 15, 2026. The procurement is a Total Small Business set-aside restricted to MACC Group ML-C00081 (contracts N4008524D0030 through N4008524D0038 and N4008524D0069) under the Design-Build/Design-Bid-Build MACC for projects primarily in the Hampton Roads area of responsibility. Eligible holders named in the notice are CJW Contractors, Inc., Addon Services LLC, Bay Electric Co., Inc., ENCON Desbuild JV3 LLC, Mark Turner Construction, MIG WMJ JV1 LLC, Ocean Construction Services, SAW Eastern JV, VIRTEXCO Corporation, and Within Interior Design, Inc. DBA Tazewell Contracting.

Amendment 0001, issued November 18, 2026, extended the pre-proposal question deadline from November 27 to December 2, 2026 and the proposal deadline from December 7 to December 15, 2026, both at 2:00 PM EST. Submissions go through PIEE as PDFs and must include a cover page, the Price Schedule Form (Attachment G), acknowledged amendments, and SAM.gov Representations and Certifications. Late submissions are not accepted.

Work is performed at Building 362 on NAS Oceana's Dam Neck Annex, Virginia Beach, VA 23460. Scope includes demolishing five existing radiant heaters and associated natural gas piping, installing natural gas-fired radiant heaters (minimum 80 MBh) and unit heaters (minimum 600 MBh), replacing one 10,000 cfm rooftop exhaust fan, installing two High Volume Low Speed fans, and providing DDC controls with fire alarm integration. The roof system is replaced with R-20 minimum insulation and up to twelve six-inch pipe penetrations. The Designer of Record must be a licensed architect or engineer whose seals appear on all design drawings. The QC Manager requires five years of combined experience and current NAVFAC Contractor Quality Management certification. Building 362 remains operational, so utility outages must be scheduled in advance. Work hours are Monday through Friday, 0730 to 1600, excluding federal holidays, and personnel access runs through DBIDS with base passes and escorts.

Performance period is 455 calendar days from task order award, with liquidated damages of $259.53 per calendar day for delay. The estimated price range is $1 million to $5 million. Award is lowest-price to the responsible offeror. The bid bond must equal at least 20 percent of the offer price or $3 million, whichever is less. Performance and payment bonds are due 15 calendar days after award, and offers must remain valid for 180 days. Wage Determination VA20260167 applies. NAICS is 236220, Commercial and Institutional Building Construction, and PSC is Z2AZ.

Notice text

2 versions

Update #2 · Latest ·

PIEE DESCRIPTION: REPLACE RADIANT HEATING SYSTEM AND EXHAUST FAN, BLDG. 362 DAM NECK ANNEX, VIRGINIA BEACH, VA. See General Requirements and all applicable attachments. This solicitation and all applicable attachments are restricted to MACC GROUP: ML-C00081 (N4008524D0030-0038 AND N4008524D0069) only under the DESIGN-BUILD (DB)/DESIGN-BIDBUILD (DBB), INDEFINITE DELIVERY/INDEFINITE QUANTITY (ID/IQ) MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) SMALL BUSINESS SET ASIDE CONSTRUCTION PROJECTS PRIMARILY IN THE HAMPTON ROADS, VIRGINIA AOR. Login to PIEE and search N4008527R0037 to obtain more details.

Update #1 ·

PIEE DESCRIPTION: REPLACE RADIANT HEATING SYSTEM AND EXHAUST FAN, BLDG. 362 DAM NECK ANNEX, VIRGINIA BEACH, VA. See General Requirements and all applicable attachments. This solicitation and all applicable attachments are restricted to MACC GROUP: ML-C00081 (N4008524D0030-0038 AND N4008524D0069) only under the DESIGN-BUILD (DB)/DESIGN-BIDBUILD (DBB), INDEFINITE DELIVERY/INDEFINITE QUANTITY (ID/IQ) MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) SMALL BUSINESS SET ASIDE CONSTRUCTION PROJECTS PRIMARILY IN THE HAMPTON ROADS, VIRGINIA AOR. Login to PIEE and search N4008527R0037 to obtain more details.

Files

Show all 11

Similar open opportunities

Opportunity Agency Set-aside Responses due
Replace HVAC equipment, building 501, DAM neck annex NAICS 236220 Naval Facilities Engineering Command No set-aside
Replace HVAC System and Components at CAD593 Cheatham Annex, Williamsburg, VA, Naval Weapons Station Yorktown. 23691 · NAICS 236220 Naval Facilities Engineering Command Total Small Business
NTX Energy Center Heaters, Fans & Light Replacement Dallas, Texas 75216, United States · NAICS 238220 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
NNSY DD4 Duct Insulation Replacement Naval Support Activity Portsmouth, Virginia 23709 · NAICS 236210 Naval Facilities Engineering Command No set-aside
RM16-1405 building 592 renovations Philadelphia Navy Yard, PA Philadelphia, Pennsylvania 19112, United States · NAICS 236220 Naval Facilities Engineering Command Competitive 8(a)

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors