Attachment J - 4_FS_SpaceTabMaster - Final.xlsx
XLSX spreadsheet 27 KB Posted
- Attached to
- DESIGN-BUILD (DB), P-1476U NEW FIRE APPARATUS BAY CHEATHAM ANNEX, NAVAL WEAPONS STATION YORKTOWN, VIRGINIA
- Solicitation number
- N40085-26-R-0131
About this file
This is a Space Tabulation document that outlines the architectural and programmatic requirements for a new Fire Apparatus Bay facility at Naval Weapons Station Yorktown, Cheatham Annex, Williamsburg, Virginia. The facility design encompasses a total gross area of 3,136 square feet (approximately 56' x 56' footprint) with a net area of 2,503 square feet, calculated using a 1.25 net-to-gross conversion factor. The design must accommodate two medium non-ARFF apparatus bays serving as the primary functional space at 1,872 square feet total.
Supporting spaces required include a fire riser closet (20 SF), protective equipment laundry room with extractor, dryer, and drying rack (142 SF), PPE gear storage and maintenance area with 11 storage lockers (136 SF), decontamination room with utility sink and shower (40 SF), unisex ABA-compliant toilet (40 SF), transition vestibule with minimum 6-foot depth walk-off mat per UFC requirements (58 SF), secure equipment storage with shelving (85 SF), and mechanical room (110 SF). The document specifies ideal dimensions for each space and notes that design-build contractors must provide actual areas in both square feet and square meters in their proposals. A conceptual floor plan diagram detailing adjacencies is referenced in the solicitation attachments.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Space Tabs
| Space Tabulation | ||||||
| Space Name | # of spaces | Unit SF (Net) | Total SF (Net) | Total SQM (Net) | Ideal Dimensions | Remarks |
| Maintenance & Apparatus | ||||||
| 100 - Apparatus Bay | 2 | 936 | 1872 | 173.91 | SEE UFC | Two (2) Medium Apparatus Bays (non ARFF) |
| 101 - Fire Riser Closet | 1 | 20 | 20 | 1.86 | 2'x10' | |
| 102 - Protective Equipment Laundry | 1 | 142 | 142 | 13.19 | 10'x14' | PPE EXTRACTOR , DRYER, DRYING RACK & FOLDING TABLE (FFE) |
| 103 - PPE Gear Storage\Maintenance | 1 | 136 | 136 | 12.63 | 10'x13' | 11 PPE Gear Storage Lockers (FFE) |
| 103A - Decontamination | 1 | 40 | 40 | 3.72 | 5.5'x7' | Utility Sink and Decontamination Shower |
| 104 - Unisex Toilet | 1 | 40 | 40 | 3.72 | 5.5'x7' | ABA Toilet and Sink |
| 105 - Transition Vestibule | 1 | 58 | 58 | 5.39 | 5.5'x10' | Provide 6' minimum depth walk off mat per UFC requirements. |
| 106 - Secure Storage | 1 | 85 | 85 | 7.90 | 8.5'x10' | Shelving & equipment FFE |
| 107 - Mechanical Room | 1 | 110 | 110 | 10.22 | 9'x12' |
| Subtotal Net Area | 2503 | 232.54 | |
| Net to Gross Factor | 1.25 | ||
| TOTAL GROSS AREA | 3136 | 0.00 | 56'x56' Aproximate Footprint |
| The design build contractor shall provide actual area in both square feet and square meters in proposals. | |||
| See ATT (01) CONCEPTUAL FLOOR PLAN DIAGRAM in Part 6 Attachments for adjacencies. |
&"Calibri,Regular"P1476U Construct New Fire Apparatus Bay at CAD 119 Naval Weapons Station Yorktown, Cheatham Annex, Williamsburg, VA &"Calibri,Regular"WON 1832581