214261_MECH-1.pdf
PDF 3 MB Posted
- Solicitation number
- W91QVN19R0184
About this file
214261_MECH-1
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
SYMBOLS AND ABBREVIATIONS
MECHANICAL MATERIAL INDICATIONS &
M E C H A N I C A L M A T E R I A L I N D I C A T I O N S & S Y M B O L S
NTS
PD
Pa
OS&Y
OXY
OD
OAIL
OA
QT
PRV
PPM
POL
POC
PLMB
PH
PG
RT
RPM
RH
RDTR
RA
R12, R22
QTY
A B B R E V I A T I O N S
SBM
SAN
SA
SCH
FLOWMETER, ORIFICEBUTTERFLY
REFRIGERANT LIQUID
CHILLED WATER SUPPLY
CHILLED WATER RETURN
AIR COOLED CONDENSING UNIT
AIR CONDITION UNIT (S)
APPARATUS DEW POINT
AIR CONDITION (-ING,-ED)
CHILLED/HOT WATER RETURN
AMERICAN WIRE GAUGE
PRESSURE, BAROMETRIC
CUBIC METER PER HOUR
CHILLED/HOT WATER SUPPLY
CAPACITYCAP
CONNECTION
CONTINUE
COMPRESSOR
CUBIC METER
CPRSR
CONN
CONT
CU M
CHILLED WATER
CAST IRON PIPE
CIRCUIT
CLASSIFICATION
COOLING LOAD
COEFFICIENT
COUNTER CLOCKWISE
CLASS
CLG LOAD
COEF
CMH
CIP
CCW
CHW
CKT
ACV ALARM CHECK VALVE
AVERAGEAVG
BOILING POINT
CENTIGRADE
BAROMETER(-TRIC)
BRAKE HORSEPOWER
BP
BHP
C
BARO PR
AWG
BARO
ALUMINUM
ALTITUDE
AMBIENT
AIR HANDLING UNIT
AMPERE(AMP, AMPS)
APPROXIMATEAPPROX
ALT
AMB
AMP
AIR COND
ADP
AL
AHU
AIR COOLED
ACCU
ACLD
ACU
CHR
C/HWR
C/HWS
CHS
RL
D DRAIN
DIAMETER, INSIDE
ISOMETRIC
IRON PIPE SIZE
JOULE
THERMAL CONDUCTIVITY
KILOGRAM
KILOGRAM PER SQ. CENTIMETER (GAUGE)
KILOGRAM PER SQ. CENTIMETER
KILOGRAM PER SQ. CENTIMETER (ABSOLUTE)
KILOCALORIE PER HOUR
EXPANSION JOINT
EXPLOSION PROOF
FIRE HOSE CABINET
FULL LOAD AMPERES
ENTERING WATER TEMP
EVAPORAT (-E,-ING,-ED,-OR)
EXTERNAL STATIC PRESSURE
FACE AREA OR FRESH AIRFA
FHC
FHY
FLA
FIRE HYDRANT
ESP
EXPJT
EWT
EVAP
EP
EQPT
ENT
EFF
EQUIPMENT
ENTERING
EFFICIENCY
KG/SQ CM
KG/SQ CM A
KG/SQ CM G
KG
KCAL/HR
J
K
ID
ISO
IPS
NO
N.O.
NIC
NPT
MPS
NC
N/A
N.C.
MAX
MIN
MPH
MM
NOT IN CONTRACT
NATIONAL TAPER PIPE (THREAD)
NUMBER
NORMALLY OPEN
MINIMUM OR MINUTE
METERS PER HOUR
METERS PER SECOND
NORMALLY CLOSED
NOISE CRITERIA
NOT APPLICABLE
MAXIMUM
MILLIMETER R
FEMALE PIPE THREAD
FUEL OIL
GALVANIZED STEEL
GAGE OR GAUGE
FIXTURE
FEED WATER PUMP
FACE VELOCITY
FLUSH VALVE
FREQUENCY
FIBERGLASS REINFORCED PLASTIC
HORIZONTAL
HOT WATER HEATER
HOT WATER
HOUR(S)
HORSEPOWER
MERCURY
HEAD
HOSE BIBB
HERTZ
GRAMS
FRPCWP CIRCULATING WATER PUMP
DIRECT EXPANSION
DRY PIPE VALVE
EQUIVALENT DIRECT RADIATION
ENTERING AIR TEMPERATURE
DOUBLE POLE DOUBLE THROW
DEWPOINT TEMPERATURE
DRY BULB TEMPERATURE
DECIBEL OR DRY BULB
DIESEL OILDO
ECON
ECC
EAT
EDR
DX
DPV
DPDT
DPT
ECONOMIZER
ECCENTRIC
o
DIFF
DIAG
DIA or
DIV
DBT
DB
DIFFERENCE
DIAGRAM
DIAMETER
DIVISION
DEGREE
HR
HORIZ
HWH
HW
HZ
HP
HG
HD
HB
GALVS
GA
GR
FXTR
FWP
FVEL
FV
CUBIC MILLIMETER
CLOCKWISE OR COLD WATER
COEFFICIENT, VALVE FLOWCv
CU MM
CW
PLUG VALVE
THREE WAY
FPT
FO
FREQ
GATE, ANGLE
GATE, GLOBE
GLOBE
GATE
CONTROL
KJ KILOJOULE
LH
LT
LWT
LPS
M
LL
LPD
LPH
LM
LAV
LAT
LBS
LG
KW
KWH
L
LATENT HEAT
LEAVING WATER TEMPERATURE
LITERS PER HOUR
LITERS PER SECOND
LAUNDRY TRAY
METERS
LIQUID LINE
LITERS PER DAY
LINEAR METER
LEAVING AIR TEMPERATURE
LAVATORY
POUNDS
LENGTH
KILOWATT
KILOWATT HOUR
LITERS
P
FLOWMETER, VENTURI
FLOW SWITCH
PRESSURE SWITCH
PRESSURE GAUGE AND COCK
PUMP (INDICATE USE)
STRAINER
STRAINER, BLOW OFF
KG/SM
KG/SM A
KG/SM G
PS
P
OFM
FS
VFM
KILOGRAM PER SQ. METER
KILOGRAM PER SQ. METER (ABSOLUTE)
KILOGRAM PER SQ. METER (GAUGE)
JACKET WATER RETURN
MEDIUM PRESSURE STEAM
MEDIUM PRESSURE CONDENSATE
LOW PRESSURE STEAM
LOW PRESSURE CONDENSATE
BOILER BLOW DOWN
PUMPED CONDENSATE
JACKET WATER SUPPLY
VACUUM PUMP DISCHARGE
FUEL OIL TANK VENT
CONDENSATE WATER SUPPLY
CONDENSATE WATER RETURN
MEDIUM TEMPERATURE HOT WATER SUPPLY
MEDIUM TEMPERATURE HOT WATER RETURN
LOW TEMPERATURE HOT WATER SUPPLY
LOW TEMPERATURE HOT WATER RETURN
PIPE TO BE REMOVED
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
LPS
CONTROL AIR MAIN
air conditioning and refrigeration
RD
RS
(NAME)E
(NAME)
M
EXISTING PIPE
COMPRESSED AIR
VACUUM (AIR)
HWR
VAC
A
MTWS
MTWR
HWS
FOD FUEL OIL DRAIN
FOR
CS
CR
FOV
FOG
FOS FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL GAUGE
PC
VPD
MU
LPC
BBD
MAKE UP WATER
MPS
MPC
JWR
JWS
heating
PIPING
CHECK, SWINGSANITARY DRAIN
PITCH OR PIPE, UP(U), DOWN(D)
FLOOR SINK (200mm x 200mm)
PIPE SLEEVE WITH FIRE STOPPING
VENT THRU ROOF
BFP
valves : (for selective actuators)
PLAN
HOSE BIBB
AIR LINEA
BALL
ELEV.
BACKFLOW PREVENTER
PIPE SLEEVE
(NAME)
ACID
200mm x 200mm
SURFACE CLEANOUT
FLOOR CLEANOUT
FLOOR DRAIN
CHEMICAL SUPPLY PIPES
FUNNEL DRAIN, OPEN
FCO
FD
SCO
FLOOR OR GRADE
FLOOR OR GRADE
CONDENSATE DRAIN BELOW
CONDENSATE DRAIN ABOVE
ACID WASTE
GASG
CD
CD
AIR VENT, MANUAL
AIR VENT, AUTOMATIC
W/ MEASURING TAP
EXPANSION LOOP
EXPANSION JOINT
BALL JOINT
ANCHOR, MAIN
ANCHOR, INTERMEDIATE
ALIGNMENT GUIDE
AIR SEPARATOR
FLEXIBLE CONNECTOR
SQUARE HEAD BALANCING COCK
EJ
S
MV
AVV
CHECK, NON-SLAM
CONTROL, ELECTRIC-PNEUMATIC
CONTROL, PNEUMATIC-ELECTRIC
QUICK OPENING
PRESSURE REDUCING
NEEDLE
LOCK SHIELD
HOSE END DRAIN
SAFETY
RELIEF
SQUARE HEAD BALANCING COCK
QUICK CLOSING, FUSIBLE LINK
R
S
PE
EP
plumbing
COLD WATER
HOT WATER RETURN
HOT WATER SUPPLY
VENT
MOTOR ELECTRIC
DIAPHRAGM
valves, special duty :
SOLENOIDS
valve actuators
M
FDAD
QUANTITY
SANITARY
SUBMERSIBLE
SUPPLY AIR
SCHEDULE
RADIATOR
REFRIGERATION TON
REVOLUTIONS PER MINUTE
RELATIVE HUMIDITY
RETURN AIR
THERMAL RESISTANCE
REFRIGERANT (12, 22, ETC)
OUTSIDE AIR INTAKE LOUVER
PRESSURE DROP OR DIFFERENCE
PRESSURE REDUCING VALVE
PHASE (ELECTRIC)
PERCENT
PARTS PER MILLION
POINT OF CONNECTION
PLUMBING
PETROLEUM, OIL AND LUBRICANTS
QUART
OUTSIDE SCREW & YOKE
DIAMETER, OUTSIDE
PRESSURE GAGE
POLE
PASCAL
OXYGEN
ALARM CHECK VALVE
SIDEWALL SPRINKLER
PENDENT SPRINKLER
UPRIGHT SPRINKLER
FIRE DEPARTMENT CONNECTION
PRE-ACTION VALVE
NOT TO SCALE
OUTSIDE AIR
(2-WAY SHOWN)
DRY-PIPE VALVE
VARIABLE AIR VOLUMEVAV
VENTILATION
PRESSURE, DYNAMIC(VELOCITY)
WATER-COOLED
WATER CLOSET
WATTHOUR OR WATER HEATER
WET BULB TEMPERATURE
WATERPROOF
WSHR
WCLD
WTRPRF
WH
WT
W/
WD
WC
WBT
WEIGHT
WITH
WASHER
WIDTH
VP
VOL
WB
W
VISC
VERT
VENT
VEL
VOLUME
WET BULB
WATT
VISCOSITY
VERTICAL
VELOCITY
MANUAL VOLUME DAMPER
SMOKE DAMPER (PROVIDE ACCESS DOOR)
PNEUMATIC OPERATED DAMPER
VLV
V
VAC
M
VALVE
VOLT
VACUUM
SPLITTER DAMPER
SD
AD
VD
grilles, registers and diffusers :
SG
SR
600/300
300x150
200mm NCD
FIGURE IS ON TOP
810mm x 400mm dampers
ELBOW, TURNED DOWN
REDUCER, CONCENTRIC
REDUCER, ECCENTRIC (STRAIGHT, INVERT)
REDUCER, ECCENTRIC (STRAIGHT, DOWN)
TEE, OUTLET DOWN
TEE, SINGLE SWEEP
sprinkler
UNION, SCREWED
UNION, FLANGED
TEE, OUTLET UP
TEE
LATERAL
CONNECTION, BOTTOM
CONNECTION, TOP
ELBOW, TURNED UP
BUSHING
CAP
WELDED
FLANGED
SOLDERED
SCREWED BELL AND SPIGOT
SOLVENT CEMENT
SOUND ATTENUATOR
DETECTORS, FIRE AND/OR SMOKE
ELECTRIC MOTOR OPERATED DAMPER
FIRE DAMPER (PROVIDE ACCESS DOOR)
BACKDRAFT DAMPER
BDD
S
TRANSITION
TURNING VANES
SF
CHANGE OF ELEVATION, RISE(R), DOWN(D)
DUCT SECTION, NEGATIVE PRESS., FIRST
ACCESS DOOR, VERTICAL OR HORIZONTAL
COWL, (GOOSENECK) AND FLASHING
ACOUSTICAL LINING
FLEXIBLE DUCT
FLEXIBLE CONNECTIONFC
FIGURE IS ON TOP
R
AD
47.2
TG
94.4
UC 13mm
DG
500/300L
DUCT WORK
810mm x 400mm
810mm x 400mm
THERMOSTAT, ELECTRIC
TRAP, ELECTRIC (INDICATE TYPE)
fitting :
R
THERMOMETER
EXHAUST AIR GRILLE OR REGISTER, CEILING
DUCT SECTION, POSITIVE PRESS., FIRST
DIRECTION OF FLOW
SR
DIFFUSER, LINEAR
RETURN AIR GRILLE OR REGISTER, CEILING
CEILING DIFFUSER, SQUARE TYPE
CEILING DIFFUSER, ROUND TYPE (200mm
(600mm x 300mmH, 472 LPS)
UNDERCUT DOOR (13mm, 47.2 LPS)
DOOR GRILLE (300mmx150mmH)
NECK DIAMETER)
TRANSFER GRILLE ASSEMBLY
LOUVER, DOOR OR WALL
(500mmWx300mmH, 94.4 LPS)
RG
RR
SUPPLY AIR GRILLE OR REGISTER, SIDEWALL
EXHAUST AIR GRILLE OR REGISTER, CEILING
SUPPLY AIR GRILLE OR REGISTER, CEILING
ER
SG
EG
EXISTING WORK TO BE REMOVED.
POINT OF CONNECTION NEW TO EXISTING
OR END OF DEMOLITION WORK
EXISTING WORK TO REMAIN.(E)
(R) REMOVE EXIST WORK
STAINLESS STEELSTS
SEC
SF
SG SPECIFIC GRAVITY
SAFETY FACTOR
SECOND
SL
SLPD
SLPS
SLPH
SP
SM
SPEC
SPDT
SPECIFICATION
SQUARE METER
STATIC PRESSURE
SENSIBLE LOAD
SQ
SSF
SST
SSU
ST
STD
STL
STOR STORAGE
STAINLESS STEEL
SQUARE
STEAM
STANDARD
STEEL
SPR SPRINKLER
SH SENSIBLE HEAT
SAYBOLT SECONDS FUROL
SAYBOLT SECONDS UNIVERSAL
LPD, STANDARD CONDITIONS
LPS, STANDARD CONDITIONS
LPH, STANDARD CONDITIONS
SINGLE POLE DOUBLE THROW
SYM
TD
TEMP
THK
THERM
TONS
TSTAT
SYMBOL
TEMPERATURE
THERMOMETER
THICKNESS
THERMOSTAT
UH
UR
UNIT HEATER
URINAL
TYP TYPICAL
HEAT TRANSFER COEFFICIENT
TEMPERATURE DIFFERENCE
TONS OF REFRIGERATION
SUCT SUCTION
C
A
B
S E T
ID
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
CHONG, ST
214621
M-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
GENERAL NOTES & SCOPE OF WORK
SCOPE OF WORK
CONTRUCTION WORK(L-WORK)
HVAC SYSTEM
SPRINKLER WORK
PLUMBING WORK
1. INSTALL WET TYPE SPRINKLER SYSTEM AND ASSOCIATED PIPING, AS INDICATED ON PLANS
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PIPING SYSTEMS SHALL BE FLUSHED, PURGED & CLEANED PER SPECS REQUIREMENTS
AND FLUSHED UNTIL ALL WATER BEING FLUSHED IS CLEAR AS TAP WATER.
ALL AIR DUCT DIMENSION SHOWN ARE INDICATED AS ACTUAL INSIDE DIMENSIONS.
DUCTWORK SHALL BE PATCHED OR RESTORED TO MATCH ADJACENT SURFACE OR AREAS.
TO SMACNA STATIC PRESSURE CLASS 500PA AND DUCTWORK SHALL MEET THE REQUIREMENTS
ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED ACCORDING
OF SEAL CLASS C.
CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE
THE EXISTING EQUIPMENT ANY EQUIPMENT, DUCT WORK, PIPING ETC. DAMAGED DUE TO
THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED OR REPLACED BY
THE CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH
THE EXISTING CONDITIONS, EQUIPMENT, FINISHES, ETC., PRIOR TO START OF WORK.
IF ANY DISCREPANCY IS DETECTED, IT SHOULD BE BROUGHT TO THE CONTRACTING OFFICER'S
REPRESENTATIVE ATTENTION WITH RECOMMENDATIONS FOR PROPER CORRECTIONS FOR
LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. APPROXIMATE
SHOP DRAWING SHALL NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.
NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWINGS.
ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED PER SPEC.
ALL WALL/FLOOR/ROOF OPENINGS RESULTED FROM THE REMOVAL OF PIPING AND
CONTRACTING OFFICER'S APPROVAL.
AND SHALL BE VERIFIED AT THE JOB SITE.
THIS CONTRACTOR.
GENERAL NOTES
PATCHED OR RESTORED TO MATCH ADJACENT SURFACE OR AREA.
ANY OPENING RESULT FROM THE REMOVAL WORK THAT'S NOT TO BE RE-USED SHALL BE
ALL HVAC PIPING/DUCTWORK TO BE REMOVED SHALL INCLUDE ALL IT'S ACCESSORIES
SUCH AS ANCHORS, HANGERS/SUPPORT, ETC.
SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACTLY
FIELD CONDITIONS. SUCH DETAILS SHALL BE PREPARED IN THE FIELD BY THE CONTRACTOR
ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE
CONTRACTING OFFICER FOR APPROVAL.
THE EXIST DUCTWORK AND INSTALL NEW DUCTWORK AND MAKE ALL NECESSARY DUCT
IF THE EXIST DUCT ELEVATION IS CONFLICTED WITH NEW PIPING INSTALLATION, REMOVE
THE EXIST DUCTWORK AND PIPING ELEVATION/LOCATION.
PRIOR TO INSTALL NEW HVAC AND PLUMBING PIPING CONTRACTOR MUST COORDINATE WITH
CONNECTION TO FUNCTION AS ORIGINALLY INTENDED.
CONCRETE REMOVAL AND RESTORATION SHALL CONFORM TO SPEC.
ALL GAS METERS, REGULATORS, GAS LEAK DETECTOR AND GAS PIPING SHALL BE INSTALLED
IN ACCORDANCE WITH LOCAL CODES AND CITY GAS COMPANY'S RECOMMENDATIONS.
1. INSTALL OUTDOOR & INDOOR SPLIT SYSTEM HEAT PUMP UNITS, OUTSIDE AIR UNIT, PIPING, CONC PAD
2. INSTALL GAS FIRED HOT WATER BOILER, FLUE VENT, COMBUSTION AIR INTAKE, GAS LEAK DETECTION CONTROL PANEL, GAS GONG, GAS LEAK DETECTOR, SHUT UP VALVE, GAS METER CABINET, GAS METER, GAS REGULATOR, VALVE CABINET
HOT WATER CIRC. PUMP, AIR SEPARATOR, EXPANSION TANK, CONC. PAD, ASSOCIATED PIPING AND ACCESSORIES.
4. INSTALL EXHAUST FANS ASSPCIATED DUCTWORKS, BACKFLOW PREVENTER & PRESSURE REDUCING STATION
AS INDICATED ON PLANS.
AS INDICATED ON PLANS.
1. INSTALL GAS FIRED DOMESTIC HOT WATER HEATER, FLUE VENT, COMBUSTION AIR INTAKE, DOMESTIC HOT WATER CIRC. PUMP, DOMESTIC HOT WATER RECIRC PUMP, CONC PAD, ASSOCIATED PIPING AND ACCESSORIES AS INDICATED ON PLAN.
3. INSTALL SEWER, VENT PIPING, FLOOR DRAIN, FLOOR CLEANOUT AND ACCESSORIES INDICATED ON PLANS.
4. INSTALL ELECTRIC WATER COOLER, EMERGENCY SHOWER AND EYEWASH, DOMESTIC HOT WATER STORAGE TANK, EXPANSION TANK, ASSOCIATED PIPING AND ACCESSORIES AS INDICATED ON PLANS.
5. INSTALL PLUMBING FIXTURES, ASSOCIATED PIPING AND ACCESORIES AS INDICATED ON PLANS.
O.A INTAKE LOUVER W/BIRDSCREEN AND MOTORIZED DAMPER, HOT WATER PIPING, INSULATION AND ACCESSORIES.
ACCESSORIES AS INDICATED ON PLANS.
2. INSTALL HOT AND COLD WATER PIPING INCLUDING VALVES, HOSS BIBBS, WATER HAMMER ARRESTS, INSULATION AND
3. INSTALL ELECTRIC WALL HEATERS, ELECTRIC UNIT HEATERS, RANG HOOD, UNIT HEATERS, SPLIT AIR CONDITIONING UNIT, DUCTWORKS, DIFFUSERS, CONTROL, PIPING, DUCTWORKS AND ACCESSORIES AS INDICATED ON PLANS.
GAS FILTER, AUTOMATIC SHUT OFF VALVE, HVAC PIPING W/INSULATION, CONC PAD AND GAS PIPING AS INDICATED ON PLANS.
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-3
208/ 1/ 60 R-410A
AS PER MANUFACTURER RECOMMENDATIONS.
3 SIMILAR TO LG MULTI V 5 MODEL ARUM121BTE5 OR APPROVED EQUAL.
129,000114,000
REFRIGERANT
TYPE
R-410A
HEATING CAPACITY SHALL BE BASED ON 8 DEG C
INDOOR HEAT PUMP UNITS 321MULTI V 5 HEAT PUMP1
T Y P EITEM NO SERVICE
RATED HEATING CAP.
(BTU/H)
REMARKSQTY.
OUTDOOR SPLIT SYSTEM HEAT PUMP UNIT
OHPU
ALL HEAT PUMP UNITS REFRIGERANT PIPING SHALL BE INSTALLED AS PER MANUFACTURER RECOMMENDATIONS.
COOLING CAPACITY SHALL BE BASED ON 35 DEG C2
1NOTES :
(BTU/H)
RATED COOLING CAP.
TYPE
REFRIGERANT
HEATING CAPACITY SHALL BE BASED ON 8 DEG C
COOLING CAP.
(BTU/H)
NOTES : 1
2 COOLING CAPACITY SHALL BE BASED ON 35 DEG C
ALL HEAT PUMP UNITS REFRIGERANT PIPING SHALL BE INSTALLED
HPU
INDOOR SPLIT SYSTEM HEAT PUMP UNIT
QTY. REMARKS
POWER INPUT
(W)
VOLT/PH/HZ
(BTU/H)
HEATING CAP. CFM
SERVICEITEM NO T Y P E
1 1 2
COMPRESSOR
HSS DC SCROLL
TYPE
3208/ 1/ 60 R-410A 2
HPU
2 1
ELECTRICAL
MOP(A) MCA(A)
40 30.9
QTY
FAN
TYPE
PROPELLER
QTY
(H/M/L)
VOLT/PH/HZ
208/ 3/ 60
208/ 1/ 60 R-410A
HPU
1 1
208/ 1/ 60 R-410A
HPU
3 1
21,50019,100 57
208/ 1/ 60
417/381/348
R-410A
HPU
2-WAY CEILING CASSETTE TYPE
6,1005,500 30
208/ 1/ 60
265/247/212
R-410A
HPU
4-WAY CEILING CASSETTE TYPE
8,5007,500 30
208/ 1/ 60
265/247/212
R-410A
HPU
4-WAY CEILING CASSETTE TYPE
10,9009,600 30283/265/2514-WAY CEILING CASSETTE TYPE
(BTU/H) (BTU/H)
COOLING CAP
VOLT/PH/HZ REMARKS
(CFM)
HEATING CAP AIR FLOW RATE ELECTRICAL DATA
2 664/519/519 16948,100 46,115
TYPE
CEILING EMBEDDED TYPE
TYPE
REFRIGERANT
R-410A
MCA MOP
151.5
AS PER MANUFACTURER RECOMMENDATIONS
ALL HEAT PUMP UNITS REFRIGERANT PIPING SHALL BE INSTALLED
HEATING CAPACITY SHALL BE BASED ON 8 DEG C
COOLlNG CAPACITY SHALL BE BASED ON 35 DEG C SIMILAR TO LG MODEL ARNU483BRZ4 OR APPROVED EQUAL. 1 2 3
1 2 3
OUTSIDE AIR UNIT
ITEM NO Q'TY
OAU
208/ 1/ 60
ELECTRICAL DATA
MCA MOP
0.84
0.25
0.25
0.25
5 8SIMILAR TO LG MULTIV MODEL ARNU183TSA4 OR APPROVED EQUAL.
9SIMILAR TO LG MULTIV MODEL ARNU053TRC4 OR APPROVED EQUAL.
10SIMILAR TO LG MULTIV MODEL ARNU073TRC4 OR APPROVED EQUAL.
SIMILAR TO LG MULTIV MODEL ARNU093TRC4 OR APPROVED EQUAL.
CHIEF SUITE
MEDICAL SUPPLY STORAGE
OFFICE/SHIFT LEADER OFFICE/DISPATCH
PHYSICAL TRAINING RM
4 SIMILAR TO LG MULTIV MODEL ARNU073TUC4 OR APPROVED EQUAL.
SIMILAR TO LG MULTIV MODEL ARNU123TRC4 OR APPROVED EQUAL.
SIMILAR TO LG MULTIV MODEL ARNU153TQC4 OR APPROVED EQUAL.
1-WAY CEILING CASSETTE TYPE 8,5007,500 40290/258/226 0.23
13,60012,300 30307/283/2474-WAY CEILING CASSETTE TYPE 0.25
17,10015,400 30388/353/3284-WAY CEILING CASSETTE TYPE 0.25
NOTES :
OHPU
1 206,000184,000 R-410AINDOOR HEAT PUMP UNITS 421MULTI V 5 HEAT PUMP HSS DC SCROLL80 57.9 2 PROPELLER 2208/ 3/ 60
4 SIMILAR TO LG MULTI V 5 MODEL ARUM192BTE5 OR APPROVED EQUAL.
208/ 1/ 60 R-410A
HPU
1 115 2 1127,30024,200 33600/530/4594-WAY CEILING CASSETTE TYPE 0.19
POWER PLUG-IN CODE 12
SIMILAR TO LG MULTIV MODEL ARNU243TPC4 OR APPROVED EQUAL.
SIMILAR TO LG MULTIV MODEL ARNU283TPC4 OR APPROVED EQUAL.3
SIMILAR TO LG MODEL ARNU963B8Z4 OR APPROVED EQUAL. 4
DORMS
FIRE INSPECTORS
CORRIDORS
KIT/DINING DAYROOM
M E C H A N I C A L E Q U I P M E N T S C H E D U L E-1
EQUIPMENT SCHEDULE - 1
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
NOTE :
PREFABRICATED ROOF CURB.4
FANS
ITEM NO Q'TY SERVICE TYPE REMARKS
HP(Pa)(LPS)
RPM
ESPAIR CAP
VOLT/PH/HZ
FAN MOTOR
W/DISCONNECT SWITCH
BIRD SCREENW/BACKDRAFT DAMPER 3
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-4
DAY ROOM
(MM)
750Wx450D
TYPE
W/BACKDRAFT DAMPER
HOOD VENTED TYPE
STAINLESS STEEL
115/1/60
LIGHTING(75W)WASHABLE FILTER1 2 BUILT-IN CONTROL SWITCH3
RANGE HOODS
Q'TYITEM NO
FAN MOTORFAN
CAPACITY
(LPS)
75.5
SERVICE
2.0 AMPS 1
VOLT/PH/HZPOWER
HOOD SIZE
32 &
REMARKS
PROVIDE UNIT MTD. DISCONNECT SWITCH.EUH
POWER(KW)
HEATING ELEMENT CAP
VOLT/PH/HZ
208/1/60
REMARKS
TYPE
SERVICEQTY
NO
ELECTRIC UNIT HEATER
HORIZONTAL
T Y P E
DISCHARGE
ITEM FAN CAPACITY
165.2 1/100 208/1/601,600
RPM HP VOLT/PH/HZAIR CAP.(LPS)
ELECTRIC WALL HEATERS
ITEM NO QTY SERVICE T Y P E
WALL MTD
ELEMENT CAPACITY
120/ 1/ 601,500
TOTAL
VOLT/PH/HZ
REMARKS
(WATTS) AMPERAGE
12.5
UNITS SHALL BE PROVIDED WITH DISCONNECT
SWITCH AND INTEGRAL THERMOSTAT.
TOILET RM AND DRYING RM
1 CEMENT LINED
TYPE
STEEL ROUND HORIZONTAL
T Y P E
DOMESTIC HOT WATER STORAGE TANK
NO
ITEM
DT
QTY.SERVICE (DIAxOVERALL
TANK SIZE
LENGTH) (LIT.)
TANK CAP. REMARKS
DOMESTIC H.W
SYSTEM
915 DIA x 1,800 LONG1,136
EF
1 62.3 1,750 120/1/60 2 31
WALL MOUNTED TYPE,
DIRECT DRIVEN, CENTRIFUGAL FAN
1,230 1/4EXHAUST AIR FAN FOR MECH RM
EF
1 62.3 1,320 120/1/60 2 31
ROOF MOUNTED TYPE,
DIRECT DRIVEN, CENTRIFUGAL FAN
1/4
EXHAUST AIR FAN FOR MECH TOILET, SHOWER
LAUNDRY AND JC
EF
1 62.3 1,550 120/1/60 2 31
DIRECT DRIVEN, CENTRIFUGAL FAN
1/40
EXHAUST AIR FAN FOR FIRE INSPECTORS
AND DORM 35
EF
1 62.3 1,750 120/1/60 2 31
ROOF MOUNTED TYPE,
DIRECT DRIVEN, CENTRIFUGAL FAN
1/4
EXHAUST AIR FAN FOR FIRE INSPECTORS
AND DORM 700 4
EF
1 62.3 1,050 120/1/60 2 31
WALL MOUNTED TYPE,
DIRECT DRIVEN, CENTRIFUGAL FANSTORAGE
EXHAUST AIR FAN FOR MEDICAL SUPPLY
35 1/100
IN-LINE TYPE
RH KIT/DINING
BF
1 62.3 120/1/60 2 31
DIRECT DRIVEN, CENTRIFUGAL FAN
70EXHAUST AIR FAN FOR LAUNDRY
IN-LINE TYPE
0.72AMPS
MECH RM
M E C H A N I C A L E Q U I P M E N T S C H E D U L E-2
EH
EES
D E S C R I P T I O N
EMERGENCY SHOWER AND EYEWASH
Q'TY
ITEM
NO
ENCON MODEL NO. 01052155 OR APPROVED EQUAL.
A SILENCING SWITCH, AND A FLASHING STROBE LIGHT FOR EACH EES.
WATER FLOW-INITATED ALARM TO INCLUDE A LOCAL AUDIBLE SIGNAL DEVICE,
INLET WATER = 1-1/4"(32mm), 20GPM (1.3LPS)
EYE WASH HEAD AND SPRAY, SHOWER OPERATED BY
BRASSTOKE ASSEMBLY WITH TWIN AREATED
200mm DIAMETER SHOWER HEAD CHROME PLATED
UNIT SHALL BE COMPLETELY SELF CONTAINED. (32)
PULL CHAIN AND EYE WASH BY PUSH HANDLE,
- DISPLAYS RED BLINKING ALARM LIGHT WHEN ACTIVATED.
- TO INCLUDE INTERMITTENT PULSING SOUND WHEN
ACTIVATED, LOCAL RESET BUTTON TO SILENCE THE
AUDIBLE ALARM.
- UNIT SHALL BE FACTORY INSULATED.
EQUIPMENT SCHEDULE - 2
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
M-5
PER MANUFACTURER RECOMMENDATIONS.
ALL AC UNITS REFRIGERANT PIPING SHALL BE INSTALLED 1 CAPACITY SHALL BE BASED ON 35 DEG C
5 INDOOR EVAPORATOR UNIT CARRIER MODEL 40MVC-009 AND
OUTDOOR UNIT CARRIER MODEL 38MVC-009 OR APPROVED EQUAL.
N O T E :
SPLIT AIR CONDITIONING UNIT
QTY. REMARKS
CONDENSER FAN
VOLT/PH/HZ
POWERPOWER QTY
OUTDOOR UNIT
POWER VOLT/PH/HZ
QTY
(KW)
COOLING CAP
(LPS)
INDOOR EVAPORATOR UNIT
COMPRESSORSERVICEITEM NO T Y P E
AIR CAP.
SHALL BE PROVIDED WITH LOW AMBIENT KIT.3
EFFICIENCY
MIN.
(SEER)
PACKAGED SPLIT AIR COOLED TYPE
ACU
1 153.4
2.70
(0.75 TON)
1.10 FLA 35 DC 1 7.5 RLA
40.0 LRA
1 115/1/600.6 FLA 13.0
HIGH WALL DUCT FREE SPLIT COOLING SYSTEM
WITH REMOTE ELECTRONIC CONTROLLER.
21 43 5COMM RM
ITEM
NO
PUMPS
DOMESTIC HOT WATER
CIRC. PUMP
P
Q'TY
PIPE MOUNTED IN-LINE, DIRECT DRIVE
CENTRIFUGAL TYPE
SERVICE TYPE
0.19 41.8 1/4 115/1/60 1,725
(LPS)
CAPACITY
(KPa)
HEAD
HP VOLT/PH/HZ
MOTOR
RPM REMARKS
DOMESTIC HOT WATER
RECIRC. PUMP
P
PIPE MOUNTED IN-LINE, DIRECT DRIVE
CENTRIFUGAL TYPE
0.62 77.5 1/2 115/1/60 1,725
EXPANSION TANK
Q'TY
ET
SERVICE TYPE
ACCEPTANCE VOL.
(LITS)
REMARKS
PRESSURE(KPa)
WORKINGITEM
NO
206.8DIAPHRAGM TYPE
HEATING WATER
SYSTEM
ELECTRIC WATER COOLER
DESCRIPTIONQ'TYITEM NO
MODEL : HALSEY TAYLER HTHB-HVRGRN8BL-WF OR APPROVED EQUAL.
STANDARD 1010.
EITHER PUSH PADS ONE OF THE TWO AND BUILT-IN PRESSURE REGULATOR. MECHANICALLY AIR
COOLED WITH AIR COOLED CONDENSER & COMPRESSOR SHALL CONFORM TO ADA/ARI
BI-LEVEL WALL MOUNTED TYPE, BUBBLER SHALL BE ACTIVATED BY DEPRESSING
POWER : 10 AMPS, 115 V, 1 PH, 60 HZ.
CAPACITY : 30.3 LPH, 32.2 DEG C TO 10 DEG C.
EWC
M E C H A N I C A L E Q U I P M E N T S C H E D U L E-3
TYPEITEM NO SERVICE
Q'TY
HEAT
RECOVERY
ELEC. POWER
SUPPLY
TEMP RISE
TEMP
REMARKS
EFFICIENCY
CASCADE
SYSTEM2
DWH BLDG. DOMESTIC
HOT WATER SYSTEM
CMHkW
OUTPUT
GROSS
CMH
GAS
INPUT
VOLT/PH/HZFLA ? ?
2,882.8112 29.14 120/1/60 60.0 16.7 97.0
CSA CERTIFY PRODUCT OR APPROVED EQAL.
NAVIEN CONDENSING WATER HEATER MODEL NPE-240S X 2EA,
CIRC. PUMP
P
CENTRIFUGAL TYPE
3.5 150 208/3/60 1,800
HOT WATER BASE MOUNTED END SUCTION
PRESSURE (KPa)
MAX WORKING
AIR SEPARATOR
ITEM NO Q'TY
AS
PIPE SIZE
TYPESERVICE
INLET
REMARKS
OUTLET
206.965 DIAPIPE MOUNTED 65 DIA W/ BUILT-IN STRAINERHOT WATER SYSTEM
ET
1 206.884DIAPHRAGM TYPE
DOMESTIC WATER
SYSTEM
CMH
B
ITEM NO
BLDG. HEATING SYSTEM1
SERVICEQ'TY TYPE
VOLT/PH/HZ
120/1/60
ELEC. POWER
12.86
GAS
INPUT
kW
OUTPUT
GROSS
FLA ?
SUPPLY
80.0
WATER TEMP
kPa
WORKING
PRESS REMARKS
92.0
EFFICIENCY
CASCADE
SYSTEM
206.85
CSA CERTIFY PRODUCT, ASME CERTIFY PRODUCT OR APPROVED EQAL.
NAVIEN CONDENSING BOILER MODEL NCB-210 X 3EA,
GAS FIRED HOT WATER BOILER
GAS FIRED DOMESTIC HOT WATER HEATER
EQUIPMENT SCHEDULE - 3
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
LADDER
TRUCK
OPER
SUV
EWC
UP
UP
JC SHOWER
FIRE
ENGINE
OPER
SUV
FIRE
ENGINE
EH
EH
EUH
300x200
200x150 x
200x100
200x150
EF
EG-2, 150x150
7LPS(TYPE OF 5)
EG-2, 150x150
35LPS(TYPE OF 3)
EF
35LPS(TYPE OF 3)
EG-2, 150x150
40LPS
EG-2, 200x200 250x150
EF
O .A
AND MOTORIZED DAMPER
LOUVER W/BIRDSCREEN
260x260 O.A INTAKE
BACKDRAFT DAMPER
WALL CAP WITH
BF
BOOSTER FAN
150 DIA.
AND MOTORIZED DAMPER
LOUVER W/BIRDSCREEN
300x300 O.A INTAKE 200x150
(OUTDOOR UNIT)
AIR CONDITIONING UNIT
ACU
CONC. PAD
ACU
S
A
25 20
E
E
32 40 25
CONN, TO EXIST COLD WATER LINE
SEE CIV. DWG.
80 32
65 40
P DOMESTIC HOT WATER
CIRC. PUMP
INTAKE (W/ WIRE MESH)
150mmDIA COMBUSTION AIR
DOMESTIC HOT WATER
RE-CIRC. PUMP
P
STORAGE TANK
DOMESTIC HOT WATERDT
DWH
CONC. PAD
CONC. PAD
MOUNTED ON CEILING
GAS LEAK DETECTOR
150mm FLUE VENT
UP THRU ROOF SEE DETAIL
AUTOMATIC SHUT OFF VALVE
G
M
G
SEE CIV. DWG.
CONN, TO GAS LINE
GAS ALARM GONG
GAS LEAK DETECTION CONTROL PANEL
GAS FILTER
GAS REGULATOR
VALVE CABINET
GAS METER
GAS METER CABINET
SHUT UP VALVE
P
3CIRC. PUMP
HOT WATER
AS
AIR SEPARATOR
ET
EXPANSION TANK
E
ET
EXPANSION TANK
BACKFLOW PREVENTER &
PRESSURE REDUCING STATION
200mm FLUE VENT
UP THRU ROOF SEE DETAIL
200mmDIA COMBUSTION AIR
INTAKE (W/ WIRE MESH)
65 65
B
HEATING BOILER
GAS FIRED HOT WATER
HOT HEATER
GAS FIRED DOMESTIC
ROOM
FIRE INSPECTORS
102103104
DORM DORM DORM
CORRIDOR-2
TRAINING RM
PHYSICAL
STAIR-2
COMM RM
SHOWER
TOILET
WOMEN
JC
LAUNDRY
MEN TOILET
SHOWER
MECH RM
STORAGE
SUPPLY
MEDICAL
STAIR-1
142 101
APPARATUS-2
SCALE : 1 / 100
NEW 1ST FL HVAC PLAN - 1
- SCALE : 1 / 50 M-6
200DIA
200DIA
FROM SECOND FLOOR
RISERS TO & FROM
65 HWS/HWR PIPE
SEE
ENLARGED MECH ROOM PLAN
1.
NOTES:
CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC SYSTEM.
OF EQUIPMENTS, DUCTWORKS AND PIPING IN FIELD(TYP)
PRIOR TO EQUIPMENTS, DUCTWORKS AND PIPING INSTALLATION.
NEW 1ST FL HVAC PLAN-1, ENLARGED
MECH ROOM PLAN, CO/NITROGEN AND
NOTES
S W
M6
M6
M6
M M
T
OUT OF CONTRACT
TV
VDVD
VD
VD
VD
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
DN DN
EF
350x250 EXHAUST DUCT
RISER FROM FIRST FLOOR
EG-2
150x150
35LPS
V.D
V.D
200x100
200x100
200x150
300x150300x200
300x150
200x150 x
35LPS(TYPE OF 2)
EG-2, 150x150
115LPS
RG-1, 250x250
(TYP)
VOLUME DAMPER
115LPS
EG-1, 250x250
125LPS
EG-1, 250x250
VD
180LPS
EG-2, 350x350
EF
RISER FROM FIRST FLOOR
250x150 EXHAUST DUCT
200x150
RH
300x150
V D
125LPS
RG-1, 250x250
VD VD
EH
EH
FROM SECOND FLOOR
RISERS TO & FROM
65 HWS/HWR PIPE
TOILET
OFFICE
OFFICE
LEADER
SHIFT
DISPATCH
SHOWER
TOILET
CORRIDOR-3
DAYROOM
KITCHEN/DINING
CHIEF SUITE
STAIR-2
STAIR-1
APPARATUS
(BELOW)
SCALE : 1 / 100
NEW 2ND FL HVAC PLAN - 2
M-7
1.
NOTES:
CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC SYSTEM.
OF EQUIPMENTS, DUCTWORKS AND PIPING IN FIELD(TYP)
PRIOR TO EQUIPMENTS, DUCTWORKS AND PIPING INSTALLATION.
NEW 2ND FL HVAC PLAN-2 AND NOTES
M7
M M
M M
OUT OF CONTRACT
V.D
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
LADDER
TRUCK
OPER
SUV
UP
UP
JC
FIRE
ENGINE
OPER
SUV
APPARATUS
FIRE
ENGINE
O .A
MD
OAU
AND MOTORIZED DAMPER
LOUVER W/BIRDSCREEN
600x300 O.A INTAKE
150x100
V.D
200x150200x200250x200 150x100150x100
150x100 150x100 x x
100x100
V.D
V.D
V.D
V.D
44.4LPS(TYPE OF 5)
CD, 100DIA.
33.3LPS(TYPE OF 2)
CD, 75DIA.
ROOM
FIRE INSPECTORS
102103104
DORM DORM DORM
CORRIDOR-2
TRAINING RM
PHYSICAL
COMM RM
MECH RM
STORAGE
SUPPLY
MEDICAL
STAIR-1
SHOWER
JC
LAUNDRY
MEN TOILET
SHOWER
TOILET
WOMEN
APPARATUS-2
STAIR-2
SCALE : 1 / 100
NEW 1ST FL HVAC PLAN - 3
M-8
1.
NOTES:
CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION
2.
OF DUCTWORKS IN FIELD(TYP)
CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK.
PRIOR TO DUCTWORK INSTALLATION.
NEW 1ST FL HVAC PLAN-3 AND NOTES
M8
M M
T
OUT OF CONTRACT
V.D
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
DN DN
TOILET
MEN
MD
150x100
100x100 200x150 x 0 200x150
150x100
250x200200x150
150x100100x100
VD
VD
VD
VD VD
VD
VD
AND MOTORIZED DAMPER
LOUVER W/BIRDSCREEN
600x300 O.A INTAKE
OAU
58.3LPS(TYPE OF 4)
CD, 100DIA.
38.8LPS(TYPE OF 2)
CD, 75DIA.
TOILET
OFFICE
OFFICE
LEADER
SHIFT
DISPATCH
SHOWER
TOILET
CORRIDOR-3
DAYROOM
KITCHEN/DINING
CHIEF SUITE
STAIR-2
STAIR-1
APPARATUS
(BELOW)
SCALE : 1 / 100
NEW 2ND FL HVAC PLAN - 4
M-9
1.
NOTES:
CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION
2.
OF DUCTWORKS IN FIELD(TYP)
CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK.
PRIOR TO DUCTWORK INSTALLATION.
NEW 2ND FL HVAC PLAN-4 AND NOTES
M9
M M
M M
OUT OF CONTRACT
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
MECHANICAL
LADDER
TRUCK
OPER
SUV
UP
UP
JC
STAIR-1
STAIR-2
FIRE
ENGINE
OPER
SUV
FIRE
ENGINE
O .A
40mm CONDENSATE DRAIN
HPUHPUHPUHPU
OAU
HPU
HPU
OHPU
OHPU
HPU
RG: O 12.7
RL: O 6.35
RG: O 12.7
RL: O 6.35
RG: O 12.7
RL: O 6.35RL: O 9.52
RG: O 19.05
RL: O 9.52
RG: O 15.88
RG: O 15.88
RL: O 9.52
RG: O 12.7
RL: O 6.35 RL: O 9.52
RG: O 15.88
RL: O 9.52
RG: O 15.88
RG: O 28.58
RL: O 12.7
RG: O 28.58
RL: O 15.88
RL: O 6.35
RG: O 12.7
D: O32
D: O25
D: O25
D: O25
D: O25
RL: O 6.35
RG: O 12.7
RG: O 12.7
RL: O 6.35
ROOM
FIRE INSPECTORS
102103104
DORM DORM DORM
CORRIDOR-2
TRAINING RM
PHYSICAL
COMM RM
MECH RM
STORAGE
SUPPLY
MEDICAL
STAIR-1
SHOWER
JC
LAUNDRY
MEN TOILET
SHOWER
TOILET
WOMEN
APPARATUS-2
STAIR-2
SCALE : 1 / 100M10
NEW 1ST FL HVAC PLAN - 5
T
TTT
T
T
T
M-10
1.
NOTES:
CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION
2.
OF HEAT PUMP SYSTEM IN FIELD(TYP)
CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HEATPUMP SYSTEM.
PRIOR TO HEATPUMP SYSTEM INSTALLATION.
NEW 1ST FL HVAC PLAN-5 AND NOTES
13 10 10 10
M M
T
OUT OF CONTRACT
DORMITORY OF NEW FIRE STATION, K16
CONSTRUCT BUILDING FOR OFFICES AND
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M1 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M2 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M3 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M4 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M5 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M6 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M7 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M8 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M9 |
| 214621_CONSTRUCT BUILDING FOR OFFICES AND DORMITORY OF NEW FIRE STATION, K16_M10 |