About this file

214261_ELEC_1

View the file

Other files

File Type Posted
A21_W91QVN19R01840001.pdf PDF
209625_TITLE.pdf PDF
214261_STRUCTURAL-1.pdf PDF
209625_ARCH-2.pdf PDF
209625_MECH-2.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-ARCH.xlsx XLSX spreadsheet
214261_TITLE_R1.pdf PDF
214261_CIVIL-1.pdf PDF
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-CIVIL.xlsx XLSX spreadsheet
214261_ARCH-2.pdf PDF
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-MECH.xlsx XLSX spreadsheet
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-ARCH.xlsx XLSX spreadsheet
209625_STRUC-2.pdf PDF
214261_ELEC_3.pdf PDF
214261_CIVIL-2.pdf PDF
209625_ELEC.PDF PDF
209625_STRUC-1.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-MECH.xlsx XLSX spreadsheet
214261_ARCH-3.pdf PDF
214261_ARCH-1.pdf PDF
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-ELEC.xlsx XLSX spreadsheet
214261_STRUCTURAL-2.pdf PDF
214261_STRUCTURAL-3.pdf PDF
214261_ELEC_2.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-CIVIL.xlsx XLSX spreadsheet
214261_MECH-2.pdf PDF
209625_STRUC-3.pdf PDF
214261_MECH-1.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-STRU.xlsx XLSX spreadsheet
209625_ARCH-1.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-ELEC.xlsx XLSX spreadsheet
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-STRU.xlsx XLSX spreadsheet
A21_W91QVN19R0184.pdf PDF
209625_MECH-1.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES

1.

2.MOUNTING HEIGHTS ABOVE FLOOR SHALL BE AS FOLLOW UNLESS OTHERWISE

NOTED ON THE DRAWING.

LIGHTING FIXTURE SEE LIGHTING FIXTURE SCHEDULE

PANELBOARD SEE SPECIFICATION

SAFETY SWITCH 1524mm TO CENTER OF THE ENCL

350mm TO CENTER OF THE ENCL

MOTOR CONTROLLER 1524mm TO CENTER OF THE ENCL

3.

4.

6.THE SOIL RESISTANCE TO GROUND FOR THE ELECTRICAL AND COMMMUNICATION

SYSTEMS SHALL BE 25 OHMS OR LESS. THE SOIL RESISTANCE TEST SHALL BE

7.

5.

CONDUCTED BY THE CONTRACTOR TO OBTAIN THE REQUIRED SOIL RESISTANCE.

INDICATEDS 2 #12AWG IN 16C

INDICATEDS 3 #12AWG IN 16C

INDICATEDS 4 #12AWG IN 16C

A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS;

1219mm TO CENTER OF THE ENCLWALL SWTICH

CONDUIT UNLESS OTHERWISE INDICATED.

ALL EQUIPMENT CONTROL WIRING SHALL BE #14 AWG. "TW" IN 16C

AND LOCATION OF THE F/A ANTENNA WITH THE CENTRAL FIRE DEPARTMENT

THE CONTRACTOR SHALL SUBMIT THE SHOP DRAWING FOR THE MOUNTING

TO TRANSMIT THE ALARM RADIO SIGNAL WAVE WITHOUT ANY OBSTRUCTION.

DETAIL OF THE F/A ANTENNA, AND COORDINATE THE MOUNTING HEIGHT

F/A EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.

THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

SCOPE OF WORKS

LEGEND, GENERAL NOTES AND

E-1

12.

13.

14.

10.

11.

8.

9.

15.

SINGLE POLE TOGGLE SWITCH, 15A-125V

L E G E N D

FLEXIBLE CONDUIT W/CONNECTORS

LIGHTING

WIRING

POWER

INTERIOR

S

SYMBOL DESCRIPTION

DESCRIPTION

DESCRIPTION

T

J

THERMOSTAT (UNDER MECH. ITEM)

JUNCTION BOX

SYMBOL

SYMBOL

F FAN MOTOR (UNDER MECH. ITEM)

SAFETY SWITCH

C CONTROL CIRCUIT

3-WAY SWITCH, 15A-125V

AND GOVERNMENT INSTALLED

GOVERNMENT FURNISHED

GFGI

WEATHERPROOFWP

LA LIGHTNING ARRESTER

EXPLOSIONPROOFEP

DISTRIBUTIONDIST

GROUND FAULT PROTECTIONGFP

A AMPERE

AC ALTERNATING CURRENT

AF/AT AMPERE FRAME/AMPERE TRIP

AWG AMERICAN WIRE GAUGE

BC BARE COPPER

BLDG BUILDING

BRKR BREAKER

C CONDUIT

CB CIRCUIT BREAKER

CKT CIRCUIT

CONN CONNECTION

CT CURRENT TRANSFORMER

DET(S) DETAIL(S)

DIAG DIAGRAM

DISC DISCONNECT

DWG(S) DRAWING(S)

EA EACH

EM EMERGENCY

ENCL ENCLOSURE

EXST EXISTING

F/A FIRE ALARM

FL FLOOR

FLUOR FLUORESCENT

FXTR FIXTURE

GEN GENERATOR

GND GROUND

HP HORSE POWER

HZ HERTZ

INCAND INCANDESCENT

INSTL INSTALLATION

J-BOX JUNCTION BOX

K KILO

KV KILO VOLT

KVA KILO VOLT AMPERE

LTG LIGHTING

MAG MAGNETIC

MAX MAXIMUM

MIN MINIMUM OR MINUTE

MTG MOUNTING

NO NUMBER

O/H OVER HEAD

PH PHASE

PNLBD PANELBOARD

PRIM PRIMARY

PWR POWER

Q'TY QUANTITY

RCPT RECEPTACLE

REQ'D REQUIRED

SCHED SCHEDULE

SEC SECONDARY

SPEC SPECIFICATION

STD STANDARD

SW SWITCH

TEL TELEPHONE

TYP TYPICAL

U/G UNDERGROUND

V VOLT

VA VOLT AMPERE

W WATT

W/ WITH

XFMR TRANSFORMER

& AND

CABNET TYPE, RATED WATT ON LTG SCHEDULE

LED LIGHTING FIXTURE, WALL MOUNTED OR UNDER

ON LTG SCHEDULE, WET LOCATION

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

FAULT PROTECTED TYPE

DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED

PANELBOARD

HOMERUN CIRCUIT TO PANELBOARD

TYPE OF MTG ON LTG SCHEDULE

EXTERIOR LED LIGHTING FIXTURE, RATED WATT &

TYPE

DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING

ABBREVIATION

THE COTNRACTOR SHALL SUBMIT A SHOP DRAWING OF HVAC SYSTEM

IN ACCORDANCE WITH SEQUENCE OF OPERATION INDICATED ON THE

MECHANICAL DRAWINGS.

ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2-#12AWG

WIRES IN 16C CONDUIT UNLESS OTHERWISE INDICATED.

THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR

ELECTRICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.

CATV BEFORE CONSTRUCTION.

CONTRACTOR SHALL COORDINATE WITH AREA MP, DO IMO, SIGNAL BRIGADE,

AND GOVERNMENT ACCEPTANCE.

PANELBOARD DOOR, REQUIRED BEFORE FINAL BUILDING INSPECTION

CONTRACTOR SHALL MAKE CIRCUIT CHARTS AND ATTACH THEM TO

FIRE CODE AND SPECIFICATIONS.

OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,

ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS

OR RENOVATION.

CONDITION AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFING ALL EXISTING

FIXTURE A MINIMUM DISTANCE OF 458mm.

FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING

FACP

FTR

AUXILIARY

DESCRIPTIONSYMBOL

STROBES

WALL MOUNTED SPEAKER /COMBO. (FA+MNS)VISUAL

BUILDING TRANSMITTER UNIT FOR FIRE ALARM

SYSTEM

L

PHOTOCELL

WP

FAULT PROTECTED TYPE, WEATHER PROOF

DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED

TYPE

SINGLE RECEPTACLE, 2P-3W-20A-125V, GROUNDING

L

L

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

W/EMERGENCY BATTERY UNIT

L

W/EMERGENCY UNIT TYPE

QUADPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

ON LTG SCHEDULE

LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG

L

L

UNITS.

CERTIFICATE FROM MANUFACTURER FOR LED LIGHTING FIXTURES AND POWER

CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE 10YEARS WARRANTY

16.

THE GRADING LINE OF NEW DUCTS WILL BE LIMITED TO THE

WIDTH OF DUCT EXCAVATION.

AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.

TO THEIR ORIGINAL CONDITION AND OPERATION DURING

ALL DAMAGED AREA INCLUDING SODDING, UTILITIES, STRUCTURES

THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING

LIGHTING CONTACTOR, SEL SW (H-O-A)

THE MANUFACTURER AND MODEL OF NEW BUILDING TRANSMITTER EQUIPMENT

IN THE CENTRAL FIRE DEPARTMENT.

THE EQUIPMENT SHOULD BE TESTED WITH THE RECEIVING SYSTEM(D21)

SHALL BE COORDINATED WITH THE CENTRAL FIRE DEPARTMENT.

RECEPTACLE

FIRE ALARM CONTROL PANEL

AND WALL

WIRING CONCEALED OR EXPOSED IN/ON THE CEILING

CEILING OR CONCEALED IN NEW WALL.

ALL WIRING SHALL BE CONCEALED ABOVE CEILING WHEN THE ROOM HAS

SCOPE OF WORK

3S

A. NEW WORK ( L )

1.

2.

3.

4.

5.

8.

ASSOCIATED WIRE & CONDUIT.

INSTALL NEW PA SYSTEM INCLUDING SPEAKERS W/ ACCESSORIES AND

7.

ACCESSORIES AND ASSOCIATED WIRE & CONDUIT.

INSTALL NEW CATV SYSTEM INCLUDING CATV OUTLETS W/COVER PLATES,

TEST WELLS.

INSTALL NEW GROUNDING SYSTEM INCLUDING GROUNDING RODS, WIRE AND 6.

4-WAY SWITCH, 15A-125V4S

TYPE OF MTG ON LTG SCHEDULE

EXTERIOR FLOOD LED LIGHTING FIXTURE, RATED WATT &

ON LTG SCHEDULE

LED LIGHTING FIXTURE, HIGH BAY LIGHT, RATED WATT

MTG ON LTG SCHEDULE

EMERGENCY LIGHTING FIXTURE, RATED WATT & TYPE OF

EXIT SIGN

TYPE (KOREAN TYPE)

DUPLEX RECEPTACLE, 2P-3W-20A-220V, GROUNDING

TYPE WITH PLUG

SINGLE RECEPTACLE, 2P-3W-20A-240V, GROUNDING

TYPE WITH PLUG

SINGLE RECEPTACLE, 4P-4W-30A-250V, GROUNDING

TYPE WITH PLUG

SINGLE RECEPTACLE, 3P-4W-50A-250V, GROUNDING

TYPE WITH PLUG

SINGLE RECEPTACLE, 3P-4W-30A-250V, GROUNDING

W/COVER PLATES ASSOCIATED WIRING & CONDUITS.

INSTALL NEW PANEL BOARDS, DRY TYPE TRANSFORMER, RECEPTACLES

ACCESSORIES AND ASSOCIATED WIRE & CONDUIT.

OUTLETS W/COVER PLATES, TELEPHONE TERMINAL BOARD, EQUIPMENT RACK

INSTALL NEW TELEPHONE SYSTEM DEVICES SUCH AS TELEPHONE/DATA

AND ASSOCIATED WIRING AND CONDUIT.

(15 OR 75 CANDELA), MICROPHONE, SPEAKER (WATTAGE AS REQ'D) DEVICE

MODULE, BUILDING TRANSMITTER, ANTENNA, VISUAL/SIGNAL STROBES

BOOSTER PANEL, MANUAL PULL STATION, SMOKE DETECTOR & RELAY

NOTIFICATION SYSTEM DEVICES SUCH AS FIREA ALARM MASS NOTIFICATION

INSTALL ADDRESSABLE FIRE ALARM CONTROL AND MASS

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

TAK, YS

214621

CONTROL/POWER WIRES AND CONDUITS FOR MECHANICAL HVAC SYSTEM.

INSTALL NEW SAFETY SWTICH, MOTOR CONTROLLERS, JUNCTION BOXES,

LIGHTING SWITCHES, ASSOCIATED WIRES AND CONDUITS.

INSTALL NEW INTERIOR LIGHTING FIXTURES, EXIT LIGHTS, EXTERIOR LIGHTS,

UP

OUT OF CONTRACT

OUT OF CONTRACT

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-2

UP

LAUNDRY

STAIR-2

UP

UP

LAUNDRY

STAIR-2

S

S

S

S

S

SS

SS

S

L1-3

S

LL L L L

L

L

L L

L

L

L

L L L L L

L

L

L

L L

L L L L L

L

L L L L

S

S

S3

SHOWER

TOILET

WOMEN

JC

LAUNDRY

MEN TOILET

SHOWER

MECH RM

STORAGE

SUPPLY

MEDICAL

COMM RM

TRAINING RM

PHYSICAL

STAIR-2

CORRIDOR-1

FIRE INSPECTORS

DORM DORM DORM

"L1"L1-1

L1-5

104 103 102

S S S S

L

DN

STAIR-2

DN

S S

S

S

S

SSSS L2-1

L2-5

LL L L

LL

L

L L L

LL

LLLL

L

L L

L

L

L

S

S

DAYROOM

KIT/DINING

CHIEF SUITE

STAIR-2

STAIR-1

TOILET

OFFICE

OFFICE

LEADER

SHIFT

CORRIDOR-2

DISPATCH

"L2"

L2-3

L

S

SHOWER

TOILET

STAIR-1

SCALE: 1/100

NEW 1ST FLOOR LIGHTING PLAN

SCALE: 1/100

NEW 2ND FLOOR LIGHTING PLAN

AT ALARM/WATCH RM(102)

TO ALARM LIGHT SWITCH

KEY PLAN

EWC

UP

JC

STAIR-2

REF

S S

BY OTHER PROJECT

PANEL "LC" TO BE INSTALLED

LIGHTING CONTACTOR

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

TAK, YS

214621

NEW 1ST AND 2ND FLOOR LIGHTING PLAN

101.6mm m m

NS-15

ELECTRICAL: 120 VAC, 50/60 HZ

MOUNTING: 21mm PIPE/SURFACE

LENS HALVES

OF TWO IMPACT-RESISTANT POLYCARBONATE

BURN STEADILY. EACH LIGHT MODULE CONSISTS

360 VISUAL SIGNAL, INDIVIDUAL LIGHT MODULES SET TO

RED ALARM LIGHT, LED, 10 WATTS, 120V

99.8mm

RED

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-3

CEILING SURFACE/PENDANT MOUNTED LIGHT EMITTING DIODE (LED)

NS-12

FIXTURE, 1PH, 120V, 45W, UL LISTED, WITH CONVERTER AND

ACCESSORIES AS REQUIRED, (NS-6a) & EM UNIT(NS-6b)

415 415

FIXTURE, 1PH, 120V, 12W, WITH CONVERTER &

CEILING RECESSED LIGHT EMITTING DIODE (LED)

143.9mm

.3 m m

210mm

NS-10

ACCESSORIES, AS REQUIRED UL LISTED POWER UNIT,

DIODE(LED) EXIT LIGHT FIXTURE 1PH, 120V, 4.99W

WALL SURFACE MOUNTED LIGHT EMITTING

NS-7

NS-4a & 4b NS-6a & 6b

NS-8

100 WALL

NS-9

245mm

254mm

NS-5a & 5b

CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)

CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)

FIXTURE, 1PH, 120V, 18W, WITH CONVERTER & ACCESSORIES,

CEILING SURFACE MOUNTED LIGHT EMITTING DIODE (LED) FIXTURE, 1PH, 120V, 18W, WITH CONVERTER & ACCESSORIES

WALL SURFACE MOUNTED LIGHT EMITTING DIODE (LED)

WET LOCATION SHOWER LIGHT TRIM, UL LISTED POWER UNIT

AS REQUIRED, UL LISTED POWER UNIT

FIXTURE, 1PH, 120V, 25W, UL LISTED, WITH CONVERTER &

CEILING RECESSED MOUNTED LIGHT EMITTING DIODE (LED)

NS-11a & NS-11b

WALL MOUNTED LIGHT EMITTING DIODE(LED) LIGHT

FIXTURE, 1PH, 120V, 45W, UL LISTED, WITH CONVERTER &

ACCESSORIES AS REQUIRED, (NS-4a) & WITH EM UNIT (NS-4b) FIXTURE, 1PH, 120V, 50W, UL LISTED, WITH CONVERTER &

ACCESSORIES, (NS-5a) & WITH EM UNIT (NS-5b) AS REQUIRED

ACCESSORIES AS REQUIRED, (NS-11a) & WITH EM UNIT (NS-11b)

NS-3

(MAX. INPUT), BATTERY BACK-UP WITH BATTERY CHARGER

WALL MOUNTED LED LIGHT FIXTURE, 1PH, 120V, 22W LED

LAMP, CONVERTER & ACCESSORIES AS REQUIRED,

WET LOCATION TYPE, UL LISTED POWER UNIT

WET LOCATIONS TYPE(IP66), UL LISTED

FIXTURE, 1PH, 120V, 60 WATT, CONVERTER AND ACCESSORIES

W/ EMERGENCY UNIT

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

TAK, YS

LIGHTING FIXTURE DETAILS

R O O M

NO NAME TYPE WATT SHT

REMARKSQTY MOUNTING

STD. DET. NO. 40-06-04

PENDANT MOUNTED

PENDANT MOUNTED

DORM (TYP)

107 CEILING RECESSED 1

PHYSICAL TRNG RM

LAUNDRY

JANITOR CLOSET

111 WOMEN'S TOILET

MECH RM

CEILING RECESSED 1

CEILING RECESSED 1

STAIR-1 1NS-6B

CEILING RECESSED 1

1 152mm ABOVE MIRROR

1 152mm ABOVE DOOR

CEILING RECESSED 1

CEILING RECESSED 2

201 CHIEF SUITE

CEILING RECESSED 1

1 152mm ABOVE MIRROR

202 TOLET

CEILING RECESSED 5

CEILING RECESSED 1

204 STAIR-2 CEILING RECESSED 2

CEILING RECESSED 2205

1 152mm ABOVE DOOR

CEILING RECESSED 2

CEILING RECESSED 1

CEILING RECESSED 1

CEILING RECESSED 1

1 152mm ABOVE MIRROR

208 TOILET

CEILING RECESSED 1

CEILING RECESSED 1

209 SHIFT LEADER OFFICE

CEILING RECESSED 1

CEILING RECESSED 1

210 OFFICE

EXTERIOR - 1 152mm ABOVE DOOR

CEILING SURFACE

PHOTO CONTROL

COMM ROOM

1 CEILING SURFACE

CEILING SURFACE

MTD BELOW DUCT WORKS

F

IR

S T F

L O

O R

S E

C O

N D F

L O

O R

TYPE

LAMP

TO

DAYROOM

KITCHEN/DINING/

FLOOR

4658mm ABOVE FINISH

FLOOR

2500mm ABOVE FINISH

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

LED

LED

NS-4A

NS-4B

LED

LED

NS-6A

NS-6B 45

LED NS-4B 45

NS-7 18LED

LED

LED

NS-6A

NS-6B

LED

LED NS-8

NS-4B

LED 45

LED

LED NS-12

LED

NS-9

LED

LED

NS-4A

NS-4B 45

NS-8 18LED

LED

LED

LED NS-5A

NS-5B 50

LED NS-6B 45

LED

LED

LED NS-3 4.99

NS-11B

NS-11A 25

LED

LED NS-5A

NS-5B 50

18LED

NS-4B 45LED

18NS-8LED

NS-5A

NS-5B

50LED

LED

LED

LED NS-5B

NS-5A 50

NS-9 22

FIRE INSPECTORS105 LED

LED NS-4B

NS-4A 45

45 1

1 CEILING RECESSED

CEILING RECESSED

LED

LED NS-4B

NS-4A 45

45 1

3 CEILING RECESSED

CEILING RECESSED

MEN'S TOILET

LED

LED NS-8

NS-4B 45

18 1

1 CEILING RECESSED

152mm ABOVE MIRROR

BATTERY PACK UNIT

WITH EMERGENCY

110 SHOWER LED NS-7 18 2 CEILING RECESSED

112 SHOWER LED NS-7 18 CEILING RECESSED2

LED

LED

NS-11A

NS-11B 25

25 2

2 CEILING RECESSED

CEILING RECESSED

BATTERY PACK UNIT

WITH EMERGENCY

MED SUPPLY STORAGE LED NS-4B 45 1 CEILING RECESSED BATTERY PACK UNIT

WITH EMERGENCY

NS-3LED 4.99 1 152mm ABOVE DOOR - EXIT SIGN

NS-4a

- EXIT SIGN

DISPATCH

SHOWER

LIGHTING FIXTURE SCHEDULE (EXTENDED BUIDLING)

119 1NS-6B FLOOR

2500mm ABOVE FINISH

LED 45CORRIDOR-3

CORRIDOR-1

CORRIDOR-2

RED ALARM LIGHT LED 10 6NS-15

150 mm BELOW CEILING

WALL MOUNTED

RED ALARM LIGHT 6NS-15 10LED

150 mm BELOW CEILING

WALL MOUNTED

60EXTERIOR

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

BATTERY PACK UNIT

WITH EMERGENCY

PHOTO CONTROL

PHOTO CONTROL

NS-7 CEILING SURFACE

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-4

G N

C

OFF

AUTO

H

WIRES

CONTROL

#14 AWG

NOT TO SCALE

CONTACTOR "LC" CONNECTION DIAGRAM

NEW EXTERIOR LIGHTING

P P -1

CONNECT TO NEW EXTERIOR LIGHTS

SW IN NEMA 1 ENCL

120V, COIL HAND-OFF-AUTO SEL.

MECHANICALLY HELD CONTACTS,

W/ 2P,20A,12OV, N.O.

TO BE INSTALLED BY OTHER PROJECT

NEW LIGHTING CONTRACTOR "LC"

FACING NORTH

1500W, 120V, ORIENTED

TO BE INSTALLED BY OTHER PROJECT,

NEW PHOTOELECTRIC CELL

CEILING RECESSED 1

BATTERY PACK UNIT

WITH EMERGENCY

LED NS-10 12

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

TAK, YS

214621

DIAGRAM

LIGHTING CONTACTOR CONNECTION

LIGHTING FIXTURR SCHEDULE & EXTERIOR

UP

DN

OUT OF CONTRACT

OUT OF CONTRACT

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-5

UP

JC

STAIR-2

EWC

UP

UP

JC

STAIR-2

"W P

"WP"

TOILET

WOMEN

JC

LAUNDRY

SHOWER

MECH RM

STORAGE

SUPPLY

MEDICAL

COMM RM

TRAINING RM

PHYSICAL

STAIR-2

CORRIDOR-1

FIRE INSPECTORS

DORM DORM

DORM

"L1"

"P3"

L1-2L1-4

L1-6

L1-8

L1-9

L1-9,10

L1-11

L1-12 L1-13

L1-14

L1-15

P3-1

P3-2

P3-3

"MDP""EM"

IN 21mm C

2-#10 AWG, 1-#10 (G)

104 103

L1-24

DC

3PH, 60HZ, PRI: 208V, SEC: 220/380V

NEW DRY TYPE TRANSFORMER

15KVA/ NEW 4#AWG8 & 1#10(G) IN 27C

CONTROL SYSTEM(MECH ITEM)

GAS LEAK DETECTOR, ASV &

DNDN DN

DAYROOM

KIT/DINING

CHIEF SUITE

STAIR-2

211 204

STAIR-1

TOILET

OFFICE

OFFICE

LEADER

SHIFT

CORRIDOR-2

SHOWER

TOILET

DISPATCH

"L2"

L2-2

P3-4

L2-4

L2-6

L2-8

L2-12

L2-13

P3-5

P3-6

L2-11

L2-10

IN 27mm C

2-#8 AWG, 1-#10 (G)

SCALE: 1/100

NEW 1ST FLOOR POWER PLAN

SCALE: 1/100

NEW 2ND FLOOR POWER PLAN

M3-19

KEY PLAN

EWC

UP

JC

STAIR-2

REF

S S

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

TAK, YS

NEW 1ST AND 2ND FLOOR POWET PLAN

E-1
E-2
E-3
E-4
E-5