About this file

214261_ELEC_3

View the file

Other files

File Type Posted
A21_W91QVN19R01840001.pdf PDF
209625_TITLE.pdf PDF
214261_STRUCTURAL-1.pdf PDF
209625_ARCH-2.pdf PDF
209625_MECH-2.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-ARCH.xlsx XLSX spreadsheet
214261_TITLE_R1.pdf PDF
214261_CIVIL-1.pdf PDF
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-CIVIL.xlsx XLSX spreadsheet
214261_ELEC_1.pdf PDF
214261_ARCH-2.pdf PDF
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-MECH.xlsx XLSX spreadsheet
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-ARCH.xlsx XLSX spreadsheet
209625_STRUC-2.pdf PDF
214261_CIVIL-2.pdf PDF
209625_ELEC.PDF PDF
209625_STRUC-1.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-MECH.xlsx XLSX spreadsheet
214261_ARCH-3.pdf PDF
214261_ARCH-1.pdf PDF
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-ELEC.xlsx XLSX spreadsheet
214261_STRUCTURAL-2.pdf PDF
214261_STRUCTURAL-3.pdf PDF
214261_ELEC_2.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-CIVIL.xlsx XLSX spreadsheet
214261_MECH-2.pdf PDF
209625_STRUC-3.pdf PDF
214261_MECH-1.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-STRU.xlsx XLSX spreadsheet
209625_ARCH-1.pdf PDF
A02_214261_CONST-OFFICE-FIRE-STATION-K16-256_MMTL-ELEC.xlsx XLSX spreadsheet
A02_209625_CONST-BAYS-FIRE-STATION-K16-256_MMTL-STRU.xlsx XLSX spreadsheet
A21_W91QVN19R0184.pdf PDF
209625_MECH-1.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE ALARM/MASS NOTIFICATION SYSTEM DIAGRAM

NOT TO SCALE

NOTES:

NFPA 72, 2013 EDITION.

PRERECORDED MESSAGES ARE IN ENGLISH AND HANGUL AT

CONTRACTOR SUBMITS SHOP DRAWINGS.

THE VOLTAGE DROP AND POWER SUPPLY CALCULATION

SHALL BE PROVIDED BY THE CONTRACTOR WHEN THE

4.

(3-FEET) FROM HVAC, HOT & COLD WATER PIPING.

ALSO CONDUITS SHALL BE RUN AWAY AT LEAST 900mmTHE FIRE ALARM SYSTEM IS CONCEPTUAL. THE

MANUFACTURER'S EQUIPMENT LISTING.

SHOP SUBMITTAL TO SHOW DETAILED INSTALLATION

MANUFACTURER'S LISTED INSTALLATION

2.

CONTRACTOR SHALL COMPLETE DESIGN AND INSTALL

13.

12.

11.

9.

SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH

AND THE MASS MESSAGE NEEDS TO HAVE PRE ALERT

PATTERN IS REQUIRED FOR FIRE ALARM EVACUATION

VOICE EVACUATION SYSTEM IN LIEU OF TEMPORAL

ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED

ELECTRICAL AND MECHANICAL SYSTEM EQUIPMENT

COORDINATE THE EXACT DEVICE LOCATIONS WITH

SWITCHES AND NON-ADDRESSABLE INITIATION

ALL TAMPER SWITCHES, FLOW SWITCHES, PRESSURE

PROHIBITED FOR ALL IDC, NAC AND SLC.

ALL CLASS "B" EXCEPTIONS IN NFPA 72, 23.4.2.2 ARE8.

7. CLASS "B" RACEWAY OF FA SYSTEM SHALL BE

SEPARATED BY A MINIMUM OF 1220mm HORIZONTAL

10. COAXIAL CABLE SHALL BE ONE PIECE BETWEEN

3.

5.

6. THE POWER CIRCUIT NUMBER DEDICATED TO FIRE

ALARM CIRCUIT AND ROOM LOCATION OF PANEL

LETTER "FIRE ALARM CIRCUIT" ON THE DEDICATED

FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED

THE FIRE ALARM/MASS NOTIFICATION SYSTEM

CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING

FIRE ALARM INTELLIGIBILITY/AUDIBILITY CALCULATION,

WIRE SIZE, CONDUIT SIZE, NO. OF WIRES FOR THE FIRE

POWER CIRCUIT BREAKER AND/OR DISCONNECT SWITCH.

SHALL BE INDICATED ON THE FIRE ALARM/MASS

BUILDING TRANSMITTER AND ANTENNA.

AND 305mm VERTICALLY.

DEVICES SHALL BE PROVIDED WITH CLASS "B"

THE SYSTEM FOR READY TO USE. THE NUMBER OF

DEVICES SHOWN IS THE MINIMUM REQUIRED AND THE

FINAL QUANTITY SHALL BE IN ACCORDANCE WITH THE

DEVICE LOCATIONS IN ACCORDANCE WITH THE

AND BUILDING ARCHITECTURAL FEATURES.

OR FM APPROVED.

SPECIFICATION SECTION 28.31.76.00.31 (FA) AND

HAVE PRE ALERT TEMPORAL PATTERN MIN 2 CYCLES

PROVIDE ADDITIONAL RELAYS AS REQUIRED.14.

18.

19.

20.

PER UFC 4-021-01.

17. THE MASS NOTIFICATION SYSTEM IS CONCEPTUAL. THE

NUMBER OF DEVICES SHOWN IS THE MINIMUM REQUIRED

AND THE FINAL QUANTITY SHALL BE IN ACCORDANCE

MANUFACTURER'S EQUIPMENT LISTING.

SHOP SUBMITTAL TO SHOW DETAILED INSTALLATION

THE MASS NOTIFICATION SYSTEM SHALL BE ENSURED THAT

LEAST FOR THE FOLLOWING ITEMS.

FOR ABBREVIATION, LEGEND, AND GENERAL NOTES

STROBES FOR MASS NOTIFICATION SHALL BE MARKED

STROBES FOR FIRE ALARM SHALL BE MARKED "FIRE"

"ALERT" IN RED LETTER AND W/AMBER LENS.

SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH

1.

AND W/CLEAR LENS.

15.

CONTINUOUS 3-10 SECOND TONE, NFPA 72, 24.4.1.2.2

& 24.4.1.8.2.

THE MASS SYSTEM ACTIVATION MUST OVERRIDE THE FIRE

ALARM NOTIFICATION APPLIANCES THE MASS SYSTEM

ON THE PANEL BY SWITCH.

THIS SEQUENCE IS REQUIRED FOR BOTH PRE-RECORDED

MASS MESSAGE IS REQUIRED TO BE ANNOUNCED

IMMEDIATELY UNTIL SHUTDOWN MANUALLY.

SPECIFICATION SECTION 28.31.76.00.31 (MNS)

THE CONTRACTOR SHALL PROVIDE THE REQUIRED

TESTING TO ACHIEVE A MINIMUM CIS SCORE 0.8 AS

16.

DEVICE LOCATIONS IN ACCORDANCE WITH THE

MANUFACTURER'S LISTED INSTALLATION

AND NFPA 72, 2013 EDITION.

APPLIANCES UNTIL MASS ALERT IS CANCELED MANUALLY

ACTIVATION MUST OVERRIDE THE FIRE ALARM NOTIFICATION

MESSAGES AND MANUAL MICROPHONE INITIATED MESSAGES.

ARE IDENTICAL TO FIRE ALARM VISUAL APPLIANCES.

23.

MASS VISUAL APPLIANCE LOCATION REQUIREMENTS

AS SHOP DRAWING SUBMITTALS.

CONTRACT DRAWINGS SHALL NOT BE SUBMITTED

ARMY AND AIR FORCE PROJECTS.

WITH ANY FIRE ALARM VISUAL APPLIANCES ON

MASS VISUAL APPLIANCES SHALL NOT BE COMBINED24.

25.

22. FIRE ALARM SYMBOLS FROM NEPA 170 SHALL BE

AND ALL VISUAL APPLIANCES WITHIN THE SAME ROOM

ALL AUDIBLE APPLIANCES WITHIN THE BUILDING21.

SHALL BE SYNCHRONIZED.

VOICE EVACUATION SPEAKERS, NEPA 72.

AUDIBLE APPLIANCES SHALL PROVIDE THE STANDARD

TEMPORAL PATTERN UNLESS NFPA 101 REQUIRES

USED.

26. SHOW WEATHERPROOF EXTERIOR SPEAKERS AT ALL

EXTERIOR DOORS OR EXTERIOR GATHERING AREAS.

SHALL BE UL LISTED OFF-THE-SHELF-EQUIPMENT AND

ALL BACK-UP AMPLIFIERS WIRING AND ARRANGEMENT27.

SHALL BE TESTED TO THE STANDARDS OF UL OR RM AS

REQUIRED BY UFC 4-21-01, PARAGRAPH 4-4.3.

BOTH KOREAN AND ENGLISH.

THE MAN SHALL HAVE PRERECORDED MASSAGES IN28.

APPLICABLE CODE, SPECIFICATIONS AND

REQUIREMENTS AND WIRE COUNT.

ALARM AND DETECTION SYSTEM.

NOTIFICATION CONTROL PANEL COVER.

MODULES.

SYSTEM. VOICE EVACUATION MESSAGE NEEDS TO

REQUIRED.

WITH THE APPLICABLE CODE, SPECIFICATIONS AND

REQUIREMENTS AND WIRE COUNT.

OF 20% SPARE ADDRESSES FOR FUTURE USE.

FIRE ALARM SYSTEM OF EACH SLC TO HAVE A MINIMUM29.

SEE SHEET NO. E-1.

2) INTRUDER/HOSTILE PERSON SIGHTED WITHIN/AROUND THE BUILDING

1) BOMB THREAT OR ACTUAL BOMB WITHIN/AROUND THE BUILDING

3) OCCUPANTS DIRECTED TO TAKE COVER WITHIN THE BUILDING

6) "ALL CLEAR" MESSAGE

TEST8)

THE BUILDING

CARBON MONOXIDE GAS DETECTION MESSAGE WITHIN/AROUND 7)

THE LOCAL AREA

5) EMERGENCY WEATHER CONDITIONS APPROPRIATE FOR

NORMAL MAIN ENTRANCE/EXIT

4) EVACUATION OF THE BUILDING USING EXITS OTHER THAN THE

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SYSTEM DIAGRAM

FIRE ALARM/MASS NOTIFICATION

ELECTRICAL

E-11

24VDC, BUILT-IN ADDRESSABLE POINTS MODULES AS REQ'D,

(AS REQ'D) & MICROPHONE. NEMA 1 ENCL

DIGITAL VOICE PANEL W/AMPLIFIER & BACK UP AMPLIFIER

BATTERY CHAREGER, POWER MODULES PANEL (AS REQ'D) AND

SYNCHRONIZATION CONTROL MODULE, POWER SUPPLY,

PROGRAMMABLE MODULE & RELAYS, LCD ANNUNCIATOR,

FIRE ALARM/MASS NOTIFICATION CONTROL PANEL (FMCP),

COMBINED ADDRESSABLE

DIGITAL VOICE MODULE, MICROPHONE, BATTERY,

FIRE ALARM/MASS NOTIFICATION

CONTROL PANEL (FMCP)

FTR

16#14 IN 21C(FOR SIGNAL)

2#12 IN 16C(FOR POWER)

(PROGRAM OF D-21 MONACO

BUILDING TRANSMITTER

BT-XM AT LEAST 16 ZONES)

#6 "BC" IN 21C

GROUND CONDUCTOR

COAXIAL CABLE

W/CONNECTORS IN 16C

OMNI-DIRECTION TYPE

FIRE ALARM ANTENNA

W/MOUNTING BRACKET

GROUND ROD, COPPER CLAD

WITH WELDING CONNECTION

STEEL, 19mmdia x 3000mmLG

SG

G ~

G

CONTROL PANEL & BOOSTER PANEL)

(INSTALLED BESIDE FIRE ALARM

(RATED AS REQ'D) (TYPICAL)

SURGE PROTECTOR

2#12 & 1#12(G) IN 16C

GROUND ROD, COPPER CLAD

GROUNDING SYSTEM #6, "BC" IN 21C

CONN TO BLDG ELECTRODE

STEEL, 19mmdiax3000mmLG

WITH WELDING CONNECTION AND

ENCLOSURE

LIGHTNING ARRESTER

W/WEATHER-PROOF

W/BATTERY & BATTERY

CHARGER, NEMA 1 ENCL

F

F

TS

J

TS

J

PS

J

125125125

TS

J

CO

F

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

SB

F

125124120122 F

M

EXT

WP

101117116115114101113112111101110109 F

M

EXT

WP

108107106105121104103102

F M

EXT

WP

119121118

F

"L3-24"

WALL MOUNTED "WP" TYPE,

NOTIFICATION SPEAKER

FIRE ALARM/MASS

(WATTAGE AS REQ'D) (TYPICAL)

W/WORDS "FIRE" + MNS-AMBER STROBE

W/WORDS "ALERT") VISUAL SIGNAL STROBES

AS REQ'D)/COMBO. (FA-CLEAR STROBE

WALL MOUNTED SPEAKER (WATTAGE

SHALL BE DE-RATED AS REQUIRED) (TYPICAL)

TAMPER SWITCH

(UNDER MECH ITEM) (TYPICAL)

FOR SPRINKLER SYSTEM

W/ADDRESSABLE MODULE

(UNDER MECH ITEM)

FOR SPRINKLER SYSTEM

W/ADDRESSABLE MODULE

PRESSURE SWITCH

(15 or 75 CANDELA MINIMUM, AMBER STROBE

LOC

TO FMCP

EXIST BUILIDNG

EXPANDED BUILDING

EXISTING FIRE ALARM/MNS SYSTEM

NEW FIRE ALARM/MNS SYSTEM

6#14 & 1#12(G) IN 16C

F

109 115 107 113

F

103102

106 105

SB

SB

SB

SB

F

TS

J

TS

J

TS

J

115 115 115

PS

J

CO

F

F

F

209205 210201203205 F

M

EXT

WP

F

M

EXT

WP

111114101101 F

M

EXT

WP

101101

F 101101

FIRE ALARM/MASS NOTIFICATION

BOOSTER PANEL (FMBP)

ADDRESSABLE MANUAL

PULL STATION (TYPICAL)

ADDRESSABLE SMOKE DETECTOR

W/ SOUNDER BASE (TYPICAL)

DETECTOR

ADDRESSABLE CARBON MONOXIDE

ADDRESSABLE SMOKE DETECTOR

BATTERY & BATTERY CHARGER, etc. NEMA 1 ENCL

GROUND LOOP ISOLATION AND TRANSIENT PROTECTION

BOOSTER PANEL, 1PH, 120VAC INPUT, 6A(MAX)

@24VDC OUTPUT W/CLASS"A" AS REQ'D WITH

SLC MODULE AS REQ'D, POWER MODULE PANEL (AS REQ'D)

AMPLIFIER(AS REQ'D) CONFIGURATION PROGRAMMABLE RELAYS,

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

TAK, YS

214621

EWC

UP

UP

STAIR-2

EWC

UP

UP

STAIR-2

STORAGE

SUPPLY

MEDICAL

STAIR-1

117TRAINING RM

PHYSICAL

STAIR-2

CORRIDOR-1

DORM DORM

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-12

G

G

G

G

GGGGG

GGG

GROUND TEST WELL

G

G

G

G

G

G

1#4/0 "BC" (TYPICAL)

G G G

G

(TYPICAL)

G

MDP

(TYP)

6000mm(MAX)

WITH WELDING CONNECTION

COPPER CLAD STEEL

19mmdia x 3000mmLG, (300mm SLACK)

POINT

WELDING

EXOTHERMIC

APPROVED EQUAL

ERICO CAT. "LPC790"

GROUNDING ROD CLAMP

GROUNDING ROD WELL

GROUND ROD,

GROUND WIRE

(TYPICAL)

#4/0 "BC"

GROUND TEST WELL DETAIL

NOT TO SCALE

CAP

GL

NON-ABSORPTING FILTER MATERIAL

VERY RESISTANT TO ACIDS AND CHEMICALS,

ERICO CAT. "T416B" APPROVED EQUAL

CONSTRUCTED OF HIGH DENSITY POLYETHYLENE,

ERICO NO. "FRCB15-16" APPROVED EQUAL

FLAT PLAIN COPPER BRAID CABLE,

STANDARD WIRE DIAMETER: 0.15mm, SCALE :

19mmdia x 3000mmLG WITH

GROUND ROD, COPPER CLAD STEEL,

WELDING CONNECTION (TYPICAL)

1#2 "BC" IN 21C(TYPICAL)

NEW 1ST FL GROUNDING SYSTEM PLAN

SCALE :

G

G

G

G

G

1#2 "BC" IN 21C

G

GROUND TEST WELL DETAIL

NEW 1ST FL GROUNDING SYSTEM PLAN &

103 102

1/100

G

FIRE INSPECTORS

DORM

MECH RM

APPARATUS

KEY PLAN

EWC

UP

JC

STAIR-2

REF

S S

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

LAUNDRY

JC SHOWER SHOWER

SCALE: 1/100

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-13

APPARATUS

(BELOW)

DN DN

TOILET

SCALE: 1/100

DN DN

TOILET

UP

UP

LAUNDRY

JC SHOWER

STAIR-2

SHOWER

EWC

UP

JC

STAIR-2

REF

S S

KEY PLAN

SS

PA S

S V R

P A

S

V

PA

V

S

PA S

P A

V R

R R

S

P A

S PA

V R

PA PA S PA

V R V R

SS

P A

S

PA S PA

P A

S PA

P A

P A

S

WP

S

S

S

S

WP

P A

P A

MECH RM

STORAGE

SUPPLY

MEDICAL

STAIR-1

COMM RM

TRAINING RM

PHYSICAL

STAIR-2

CORRIDOR-1

FIRE INSPECTORS

DORM

DORM DORM

DAYROOM

KIT/DINING

CHIEF SUITE

STAIR-2

STAIR-1

TOILET

OFFICE

OFFICE

LEADER

SHIFT

CORRIDOR-2

SHOWER

TOILET

DISPATCH

TV TV

TV

TV

8T

TV

T V

TV

TV

T V

4T TV

TV

T V

TV

CEILING FOR THE MAINTENANCE.

INSTALLED ABOVE THE CEILING SHALL BE MARKED ON THE

THE LOCATION OF PULL BOX WITH COUPLERS WHICH IS

8.

THE CONTRACTOR TO MEET THE REQUIREMENT OF CATV dB.

INITIAL TESTING OF CATV SYSTEM SHALL BE PERFORMED BY7.

6.

5.

4.

CATV PANEL; ONE VENT HIGH AND ONE VENT LOW.

PROVIDE DIAGONAL VENTS ON OPPOSITE SIDE OF3.

RETURN PATH(2-WAY) CAPABILITIES.

ALL CATV MATERIAL AND EQUIPMENT MUST HAVE2.

CABLE, etc. SHALL BE COMPATIBLE WITH THE

EXISTING BASE CATV SYSTEM. IT SHALL BE

THE SPECIFICATION OF MATERIALS SUCH AS CATV

OUTLET TAP UNITS, SPLITTERS, AMPLIFIER, COAXIAL

COORDINATED WITH BASE CATV PERSONNEL.

COORDINATE LOCATION OF "NODE EQUIPMENT" WITH

SPLITTERS, AND TAP-OFF'S ARE TO BE 2WAY AND

C-COR LINE EXTENDER, DIRECTIONAL COUPLERS,

RETURN PATH 5-42MHZ, TO INCLUDE ALL

OPERATE IN THE RANGE FROM 5 TO 860MHZ,

30 DAYS PRIOR TO PERFORMING FINAL ACCEPTANCE TESTING.

CONTRACTORS WILL COORDINATE WITH BASE CATV PERSONNEL

RESULTS WILL BE RECORDED AND AVAILABLE AT THE FINAL

PROJECTS ON USFK INSTALLATIONS FOR QUALITY ASSURANCE.

THEN, BASE CATV PERSONNEL WILL INSPECT/TEST ALL

COORDINATION WITH BASE CATV PERSONNEL ON THE TYPE OF

CABLE MATERIAL AND PASSIVE DEVICES TO BE USED MUST

BE AGREED UPON BY BASE CATV PERSONNEL, CONTRACTOR,

AND ANY QUALITY ASSURANCE BRANCH PERSONNEL i.e.

BASE CONTRACTOR PRIOR TO START OF WORK.

ATTENUATION'S TO COMPENSATE FOR dbMV LEVELS.

ACCEPTANCE INSPECTION.

CORPS OF ENGINEERS, KORO, BASE CATV PERSONNEL PRIOR

1.

NOTES

9.

CATV SYSTEM DIAGRAM

NOT TO SCALE

TO ORDERING.

AMP

(5-1000MHZ) (TYPICAL)

DEVICE ABOVE CORRIDOR CEILING

WITH 8-WAY TAP OFF AND LOCKING

CTC

EXT

G

PULL BOX (300mmx300mmx200mmD)

(TYPICAL)

WALL MOUNTED TYPE TV OUTLET

W/"0"dB LOSS FACE PLATE &

F-81 BARREL TYPE CONNECTOR

(MH:+450mm BELOW CEILING)

(TYPICAL)

QUAD SHIELDED IN 21C

COAXIAL CABLE RG 11/U

1218 1218

TV TV TV

112 110 109

(TYPICAL)

QUAD SHIELDED IN 16C

COAXIAL CABLE RG 6/U

LOCATED (TYPICAL)

WHICH DEVICE IS

ROOM NUMBER

TV TV TV

105 106 107

EXIST CATV DISTRIBUTION CABINET

TV TV TV

203203

TV

TV TV

TV

TV

TV

103105

TV

TV

TV

TV

120119

TV

TV

TV

104113

TV

TV TV

PA

TV

(5-1000MHZ) (TYPICAL)

DEVICE ABOVE CORRIDOR CEILING

WITH 4-WAY TAP OFF AND LOCKING

PULL BOX (300mmx300mmx200mmD)

EXIST U/G CCTV LINE

(TYPICAL)

QUAD SHIELDED IN 21C

COAXIAL CABLE RG 6/U

NEW UNSHIELDED CABLE

2EA OF 2-PAIR, #14AWG IN 21C

(TYPICAL)

QUAD SHIELDED IN 21C

COAXIAL CABLE RG 11/U

(TYPICAL)

QUAD SHIELDED IN 21C

COAXIAL CABLE RG 11/U

NEW UNSHIELDED CABLE

2EA OF 2-PAIR, #14AWG IN 21C

(TYPICAL)

V R

(TYPICAL)

WALL MOUNTED TYPE TV OUTLET

W/"0"dB LOSS FACE PLATE &

F-81 BARREL TYPE CONNECTOR

(MH:+450mm BELOW CEILING)

S

NEW 2ND FLOOR PA & CATV SYSTEM PLAN

103 102

(TYP)

PA VOLUME CONTROL

(TYP)

PA LOUDSPEAKER

WEATHERPROOF

WALL MOUNT

NEW 1ST FLOOR PA & CATV SYSTEM PLAN

9WATTS (TYP)

LOUD SPEAKER,

MOUNTED CONE TYPE

CEILING RECESS

CORRIDOR-3

EXISTING BUILDING S-256

EXTENDED BUILDING S-256

EXIST CATV DISTRIBUTION CABINET

APPARATUS

EXIST BUILDING

TO CATV CABINET AT

EXIST BUILDING

TO CATV CABINET AT

EXIST BUIDLING

TO PA SYSTEM AT RM102,

PLAN/ CATV SYSTEM DIAGRAM

NEW 1ST & 2ND FL. PA & CATV SYSTEM

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

STAIR-2

SCALE: 1/100

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-14

APPARATUS

(BELOW)

DN DN

TOILET

SCALE: 1/100

DN DN

TOILET

UP

UP

STAIR-2

EWC

UP

JC

STAIR-2

REF

S S

T

T

/LT

/L

T /L T /L

T /L

T T B

LAN

T/L

T/L

T /L

T /L

T /L

T /L T /L

T /L

T /L

T/L

T/L

SHOWER

TOILET

WOMEN

JC

LAUNDRY

MEN TOILET

SHOWER

MECH RM

STORAGE

SUPPLY

MEDICAL

STAIR-1

COMM RM

TRAINING RM

PHYSICAL

STAIR-2

CORRIDOR-1

FIRE INSPECTORS DORM DORM DORM

DAYROOM

KIT/DINING

CHIEF SUITE

STAIR-2

STAIR-1

TOILET

OFFICE

OFFICE

LEADER

SHIFT

CORRIDOR-2

SHOWER

TOILET

DISPATCH

(TYP)

1-TEL/1-LAN OUTLET, CAT6

(305W x 152D X LENGTH AS REQ'D)

STEEL LADDER TYPE CABLE TRAY

NEW 2ND FLOOR LAN/TEL SYSTEM PLAN

FEC

AT 1ST FLR

TO COMM ROOM

105 104 103 102

NEW 1ST FLOOR LAN/TEL SYSTEM PLAN

APPARATUS

RACK IN COMM RM (115) AT EXISTING BUILDING S-256

FROM EQUIPMENT RACK IN COMM ROOM (116) TO EQUIPMENT

PATCH CORDS (19 SET OF CAT6 CABLE IN 53C.) FOR DATA

2-4PAIR, #24AWG, CAT-6

TEL WIRE IN 27C

TO BE TERMINATED AT

PATCH PANELS(TYP)

2-4PAIR, #24AWG, CAT-6

TEL WIRE IN 27C

TO BE TERMINATED AT

PATCH PANELS(TYP)

SYSTEM PLAN

NEW 1ST & 2ND FLOOR LAN/TEL

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

EXOTHERMIC WELDING, LISTED COMPRESSION TWO-

1. THE CONNECTIONS OF THE BONDING CONDUCTOR FOR

TELECOMMUNITIONS TO THE TMGB SHALL UTILIZE

HOLE LUGS, SUITABLE AND EQUIVALENT TWO-HOLE

FINISHED FLOOR AND SHALL BE PLACED WITHIN 75mm

3. ENTRANCE CONDUITS SHALL EXTEND 150mm ABOVE

"MP" GROUNDING BUS BAR

1#6 "BC" IN 21C

NOT TO SCALE

STAMP FACING OUT" TO ENSURE THAT THEY CAN BE

4. TEST RESULTS WILL BE PROVIDED IAW THE MOST RECENT

REVISION OF THE ANSI/TIA/EIA-568.

5. LABEL ALL DROPS IAW TIA/EIA-606-A.

6. LABEL ALL GROUNDS IAW I3A.

LUGS ARE PREFERRED.

FIELD VERIFIED.

OF A WALL.

TGB

CONN TO TMGB

1#6 "BC" IN 27C

(100mm x 450mmLG x 6.4mmTHK)

GROUND BUS BAR(TGB)

TMGB

G

(TYPICAL)

CABLE SUPPORT

1-12 STRAND SINGLE MODE

FIBER OPTIC CABLE

1-12 STRAND FIBER OPTIC

110TYPE TERMINAL BLOCK

(2-100PAIR) FOR TEL

(TYPICAL)

1#6 "BC" IN 16C QUAD-PLEX RECEPTACLE

2P-3W-125V-20A GND TYPE

WITH DEDICATED CIRCUIT

(TYPICAL)

(305W x 152D X LENGTH AS REQ'D)

G

FOR TELEPHONE

1-48PORT PATCH PANEL

(MH: +3000mm AFF)

STEEL LADDER TYPE CABLE TRAY

AS REQ'D

PROVIDE PATCH CORDS

HUB(N.I.C)

TELEPHONE EQUIPMENT CABINET

1-48PORT PATCH PANEL

FOR DATA

W/ RACK MOUNTED 6-SINGLE

REAR RECEPTACLE, ON-OFF

SWITCH & CORD, 2P-3W-20A-125V

POWER SURGE PROTECTION

GROUND BUS BAR(TGB)

TELECOMMUNICATION

G

TELEPHONE TERMINAL BOARD ("TTB")

TELECOMMUNICATION MAIN

PTB

RECEPTACLES

(1-100PAIR)

ENTRANCE TERMINAL BLOCK

110 TYPE PROTECTED

1-100PAIR, #24AWG TEL CABLE

103C CONDUIT SLEEVE

G

2. "PLYWOOD WILL BE INSTALLED WITH FIRE RATED

NOTE.

SHALL BE COORDINATED WITH BASE SIGNAL COMPANY.

SYSTEM AND WIRING FOR GOVERNMENT APPROVAL. TELECOMMUNCATION WORK

7. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DETAILED TELECOMMUNICATION

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ELECTRICAL

E-15

TGB

1#6 "BC" IN 27C

G

T

2-4PAIR, #24AWG, CAT-6

TEL WIRE IN 27C

PATCH PANELS

TO BE TERMINATED AT

(305W x 152D X LENGTH AS REQ'D)

FOR TELEPHONE

1-48PORT PATCH PANEL

TO EACH DATA OUTLET AS REQ'D

TO EACH TEL OUTLET AS REQ'D

(MH: +3000mm AFF)

STEEL LADDER TYPE CABLE TRAY

TELEPHONE EQUIPMENT CABINET

1-48PORT PATCH PANEL

FOR DATA

W/ RACK MOUNTED 6-SINGLE

REAR RECEPTACLE, ON-OFF

SWITCH & CORD, 2P-3W-20A-125V

POWER SURGE PROTECTION

GROUND BUS BAR(TGB)

TELECOMMUNICATION

RECEPTACLES

L1-18

EXIST/NEW TELECOMMUNICATION SYSTEM DIAGRAM

TGB

EXISTING BLDG COMM ROOM 115

(3000mmWx2400mmHx19mmTHK FIRE RATED PLTWOOD)

EXIST

EXIST

EXIST

EXIST

EXIST

EXIST

EXIST

CONNENTED TO MAIN PANELBOARD

NEW

G

CROSS CONNECTION CORD

AS REQ'D PLUS 25% SPARES

TO BE FURNISHED BY THE

CONTRACTOR

PATCH PANEL W/"SC"

CONNECTOR

EXIST

NEW

EXIST

EXIST

NEW BLDG COMM ROOM 116

EXIST

EXIST

NEW

NEW

NEW

NEW

NEW

NEW

L1-19

QUAD-PLEX RECEPTACLE

2P-3W-125V-20A GND TYPE

WITH DEDICATED CIRCUIT

NEW

NEWCONN TO TMGB

SYSTEM DIAGRAM

EXIST/NEW TELECOMMUNICATION

CABLES IN 53C.) FOR DATA

NEW PATCH CORDS (19 SET OF CAT6

TO 110 TERMINAL BLOCK AT NEW COMM RM 116

NEW 50 PAIR TELEPHONE CABLE IN 27C

K-16

DOMITORY OF NEW FIRE STAION

CONSTRUCT BUILDING FOR OFFICES AND

E-11
E-12
E-13
E-14
E-15

File details come from the government source that posted it.