Amendment 0008 Attachment 11699393.pdf

PDF 298 KB Posted

Attached to
Construction Services of a Power Generation Microgrid at Cape Cod Space Force Station in Bourne, MA
Solicitation number
W912WJ26RA003
Issued by

About this file

This document is a technical specification section for a Power Generation Microgrid project at Cape Cod Space Force Station in Bourne, Massachusetts. The specification details electrical protection and power distribution equipment requirements for the microgrid installation.

The document specifies circuit breaker requirements including ground fault protection with adjustable settings, enclosed circuit breakers to UL 489 standards with specified voltage and current ratings, and motor short-circuit protectors (MSCPs) compliant with UL 508 and UL 489 and NFPA 70 standards. For transformers, the specification requires NEMA ST 20 general purpose, dry-type, self-cooled, ventilated units housed in NEMA 1 enclosures. Transformer tap requirements include two 2.5 percent taps above and four 2.5 percent taps below nominal capacity for units 15 kVA and larger. Insulation systems must meet 220 degrees C for transformers 15 kVA and greater with temperature rise not exceeding 80 degrees C under full-rated load in maximum 40-degree ambient conditions, or 180 degrees C for units 10 kVA and smaller with equivalent temperature constraints. Transformers are specified with 480V primary and either 80 or 115 degrees C temperature rise, with kVA ratings from 37.5 to 100 for single phase or 30 to 500 for three-phase energy efficient type, subject to compliance with 10 CFR 431, Subpart K efficiency standards.

View the file

Other files

File Type Posted
Amendment 0009 Updated Sheet Vol 1 CU-201.pdf PDF
Amendment 0009 Update Sheet X-601.pdf PDF
Amendment 0009 Updated Sheet 3-T-112.pdf PDF
Amendment 0009.pdf PDF
Amendment 0009 Update Sheet Vol 4 ES103 and ES501.pdf PDF
Amendment 0008 Attachment 11680669.pdf PDF
Amendment 0008 Attachment 11699397.pdf PDF
Amendment 0008 Attachment 11692148.pdf PDF
Amendment 0008 Attachment 11690371.pdf PDF
Amendment 0008 Attachment 11699407.pdf PDF
Amendment 0008 Attachment 11680816.pdf PDF
Amendment 0008 Attachment 11699385.pdf PDF
Amendment 0008 Attachment 11676438.pdf PDF
Amendment 0008 Submission Requirements and Evaluation Criteria.pdf PDF
Amendment 0008 Attachment 11699366.pdf PDF
Amendment 0008 Attachment 11712612.pdf PDF
Amendment 0008 Attachment 11699373.pdf PDF
Amendment 0007.pdf PDF
Amendment 0006.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0004 Submission Requirements and Evaluation.pdf PDF
Amendment 0003.pdf PDF
Attachment A - Joint Venture Agreement.pdf PDF
Amendment 0002.pdf PDF
Attachment B - Past Performance Questionnaire.pdf PDF
Attachment C - Small Business Participation Commitment Document.pdf PDF
Amendment 0001.pdf PDF
Amendment 0001 - Submission Requirements and Evaluation Criteria.pdf PDF
Submission Requirements and Evaluation Criteria.pdf PDF
Site Security Requirements.pdf PDF
JA 03 - Fire Alarm System (Redacted).pdf PDF
Solicitation W912WJ26RA003.pdf PDF
JA 02 - Disconnect Switches (Redacted).pdf PDF
JA 01 - Power Filters (Redacted).pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .