Volume_2_Appendix_B_pages_401_to_600.pdf
PDF 8 MB Posted
- Solicitation number
- W912WJ18B0016
About this file
Volume 2 401-600
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACTOR TO
REMOVE EXISTING
WATER TREATMENT
SYSTEM
COMPONENTS AND
PIPING.
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL PENETRATION FOR
NEW WATER SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED.
CUT AND PLUG EXISTING
WELL PIPE AND WELL PUMP
ELECTRICAL CONDUIT
WATER TIGHT AT
FOUNDATION INTERIOR
A
MC
MC
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
W N
O
F
D
U R
H A
M
M
A I
S
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
A
V
E
W
271 Main Street.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE
WELL PUMP, WELL CONTROLLER BOX
AND HYDROPNEUMATIC TANK AND
DISPOSE OF ALL MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL
BOX, REMOVE ELECTRICAL FEED WIRES
BACK TO MAIN ELECTRICAL PANEL AND
DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE
FROM EXISTING MAIN ELECTRICAL PANEL
TO NEW WATER SERVICE. SIZE AND
INSTALL IN CONFORMANCE WITH ALL
ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING
WATER TREATMENT SYSTEM
COMPONENTS IN ACCORDANCE WITH
THE SPECIFICATIONS.
SECTION A-A
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE
PIPING AND
COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED.
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING.
CUT AND PLUG EXISTING WELL
PIPE AND WELL PUMP ELECTRICAL
CONDUIT WATER TIGHT AT
FOUNDATION INTERIOR
A
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
NORTH VIEW
271 Main Street.dwg
272 Main Street
60275749
JANUARY 2018
00 20' 40'
NOTES:
1. SEPTIC SYSTEM IS LOCATED BEHIND THE CHURCH (#280 MAIN ST.) CONTRACTOR TO CONFIRM
LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#272
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 20'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-272MAIN.dwg
M
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND
PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
MB
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
272 Main St.dwg
NOTES:
1. DISCONNECT EXISTING
SUBMERSIBLE WELL
PUMP, WELL
CONTROLLER BOX AND
HYDROPNEUMATIC TANK
AND DISPOSE OF ALL
MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING
PUMP CONTROL BOX,
REMOVE ELECTRICAL
FEED WIRES BACK TO
MAIN ELECTRICAL PANEL
AND DISCONNECT WIRES
FROM PANEL.
3. INSTALL NEW COPPER
BONDING WIRE FROM
EXISTING MAIN
ELECTRICAL PANEL TO
NEW WATER SERVICE.
SIZE AND INSTALL IN
CONFORMANCE WITH ALL
ELECTRICAL CODE
REQUIREMENTS.
4. REMOVE AND DISPOSE
OF EXISTING WATER
TREATMENT SYSTEM
COMPONENTS IN
ACCORDANCE WITH THE
SPECIFICATIONS.
CONTRACTOR TO REMOVE EXISTING
WATER TREATMENT SYSTEM
COMPONENTS AND PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
MB
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
272 Main St.dwg
275 Main Street
N
60275749
JANUARY 2018
00 20' 40'
NOTES:
1. CONTRACTOR TO LOCATE THE EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#275
EXISTING WELL TO REMAIN
AND SHALL BE USED AS A
MONITORING WELL
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
NV
NV
1" = 40'
1 3
T O
D
U R
H A
M
M
A
R
E E
T
S I T
E
P
L A
SER-DUR-275MAIN.dwg
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE
PIPING AND
COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED.
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING.
CUT AND PLUG EXISTING WELL
PIPE AND WELL PUMP
ELECTRICAL CONDUIT WATER
TIGHT AT FOUNDATION
INTERIOR
NV
NV
3/16" = 1' - 0"
2 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
275 Main Street.dwg
N
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND HYDROPNEUMATIC TANK AND
DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL
PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW WATER SERVICE.
SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS IN ACCORDANCE WITH THE
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CUT AND PLUG
EXISTING WELL
WATER TIGHT AT
FOUNDATION
INTERIOR
CONNECT TO EXISTING
COLD WATER FEED PIPE
SECTION A-A
A
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED.
CONTRACTOR TO REMOVE EXISTING
WATER TREATMENT SYSTEM
COMPONENTS AND PIPING.
NV
NV
3/16" = 1' - 0"
3 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
275 Main Street.dwg
2 Main Street
R
E E
T
R
T E
M
M A
R
E E
T
R
T E
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. SEPTIC SYSTEM IS LOCATED BEHIND THE CHURCH (#280 MAIN ST.) CONTRACTOR TO CONFIRM
LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#280
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
MC
MC
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
N
SER-DUR-280MAIN.dwg
NOTE LOCATION
OF SEPTIC TANK
INSTALL WATER METER
PIT - SEE DETAIL
DRAWING C-503
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE DETAIL
1, SHEET C-503. PROVIDE
FITTINGS AND PIPING
SUPPORTS AS NEEDED
CONTRACTOR
TO REMOVE
EXISTING
WATER
COMPONENTS
AND PIPING
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
CONNECT
TO
EXISTING
COLD
WATER
FEED PIPE
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
MC
MC
3/16" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
280 Main Street.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP,
WELL CONTROLLER BOX AND HYDROPNEUMATIC TANK
AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE
DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE
ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL
PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING
MAIN ELECTRICAL PANEL TO NEW WATER SERVICE.
SIZE AND INSTALL IN CONFORMANCE WITH ALL
ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF ANY EXISTING WATER
TREATMENT SYSTEM COMPONENTS IN ACCORDANCE
WITH THE SPECIFICATIONS.
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
JT
JT
1/4" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
EAST VIEW
280 Main Street.dwg
289 Main Street
R
E E
T
R
T E
M A
R
E E
T
R
T E
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#289
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
NV
NV
1" = 40'
1 3
T O
D
U R
H A
M
M
A
R
E E
T
S I T
E
P
L A
SER-DUR-289MAIN.dwg
CONNECT
TO
EXISTING
COLD
WATER
FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED.
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CUT AND PLUG EXISTING WELL
PIPE AND WELL PUMP ELECTRICAL
CONDUIT WATER TIGHT AT
FOUNDATION INTERIOR
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING.
A
NV
NV
1/8" = 1' - 0"
2 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
289 Main Street.dwg
N
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND HYDROPNEUMATIC
TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO MAIN
ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW WATER
SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS IN ACCORDANCE
WITH THE SPECIFICATIONS.
CONNECT TO EXISTING COLD
WATER FEED PIPE
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING.
CUT AND PLUG EXISTING WELL
PIPE AND WELL PUMP ELECTRICAL
CONDUIT WATER TIGHT AT
FOUNDATION INTERIOR
NV
NV
1/4" = 1' - 0"
3 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
289 Main Street.dwg
293 Main Street
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#293
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-293MAIN.dwg
WATER SYSTEM
COMPONENTS
AND PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
NEW WATER SERVICE
PIPING AND COMPONENTS.
SEE DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
A
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
293 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP,
WELL CONTROLLER BOX AND HYDROPNEUMATIC
TANK AND DISPOSE OF ALL MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX,
REMOVE ELECTRICAL FEED WIRES BACK TO MAIN
ELECTRICAL PANEL AND DISCONNECT WIRES FROM
PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM
EXISTING MAIN ELECTRICAL PANEL TO NEW WATER
SERVICE. SIZE AND INSTALL IN CONFORMANCE
WITH ALL ELECTRICAL CODE REQUIREMENTS.
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING WELL PIPE
WATER TIGHT AT FOUNDATION INTERIOR
SECTION A-A
A
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
293 Main St.dwg
WEST VIEW
297 Main Street
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#297
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-297MAIN.dwg
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CONNECT TO
EXISTING COLD
WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG
EXISTING WELL PIPE
WATER TIGHT AT
FOUNDATION INTERIOR
MB
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
297 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP,
WELL CONTROLLER BOX AND HYDROPNEUMATIC
TANK AND DISPOSE OF ALL MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE
ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL
PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING
MAIN ELECTRICAL PANEL TO NEW WATER SERVICE.
SIZE AND INSTALL IN CONFORMANCE WITH ALL
ELECTRICAL CODE REQUIREMENTS.
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CONNECT TO EXISTING COLD
WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1,
SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS NEEDED
CUT AND PLUG EXISTING WELL
PIPE WATER TIGHT AT
FOUNDATION INTERIOR
MB
JT
1/4" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
297 Main St.dwg
298 Main Street
N
60275749
JANUARY 2018
00 20' 40'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#298
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
NV
NV
1" = 20'
1 3
T O
D
U R
H A
M
M
A
R
E E
T
S I T
E
P
L A
SER-DUR-298MAIN.dwg
PENETRATION FOR
NEW WATER
SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE DETAIL
1, SHEET C-503. PROVIDE
FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING WELL
PIPE AND WELL PUMP
ELECTRICAL CONDUIT WATER
TIGHT AT FOUNDATION
INTERIOR
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING.
CONNECT TO EXISTING
COLD WATER FEED PIPE
A
NV
NV
" = 1' - 0"
2 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
298 Main Street.dwg
N
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO
MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW
WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE
REQUIREMENTS.
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING.
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CUT AND PLUG EXISTING
WELL PIPE AND WELL PUMP
ELECTRICAL CONDUIT
WATER TIGHT AT
FOUNDATION INTERIOR
CONNECT TO EXISTING
COLD WATER FEED PIPE
NV
NV
" = 1' - 0"
3 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
298 Main Street.dwg
303 Main Street
M
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#303
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
N
SER-DUR-303MAIN.dwg
#305R
CONTRACTOR TO
REMOVE EXISTING
WATER SYSTEM
COMPONENTS AND
PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING WELL
PIPE WATER TIGHT AT
FOUNDATION INTERIOR
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
303 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX
AND HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED
WIRES BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM
PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL
PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH
ALL ELECTRICAL CODE REQUIREMENTS.
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION
INTERIOR
SECTION A-A
A
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
303 Main St.dwg
305R Main Street
M
N
60275749
APRIL 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#303
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW 1-1/2"
WATER SERVICE AND
CURB STOP - SEE
DETAIL DRAWING
C-503
MC
MC
1" = 40'
1 3
T O
D
U R
H A
M
R
S I T
E
P
L A
N
SER-DUR-305RMAIN.dwg
#305R
INSTALL WATER METER
PIT - SEE DETAIL
DRAWING C-503
1-1/2" TYPE K
COPPER WATER
SERVICE
COMPONENTS AND PIPING
CONNECT TO EXISTING COLD
WATER FEED PIPE
CORE AND SEAL PENETRATION FOR NEW
WATER SERVICE PIPE
A
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
M
NV
NV
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
305R Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER
BOX AND HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS
UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED
WIRES BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM
PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL
PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE
WITH ALL ELECTRICAL CODE REQUIREMENTS.
M
CONNECT TO EXISTING COLD
WATER FEED PIPE
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION
INTERIOR
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1,
SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS NEEDED
NV
NV
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
305R Main St.dwg
307 Main Street
M
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#307
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-307MAIN.dwg
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL PENETRATION FOR
NEW WATER SERVICE PIPE
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
JT
JT
16"
= 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
307 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE
DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES
BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO
NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL
CODE REQUIREMENTS.
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CORE AND SEAL
PENETRATION FOR
NEW WATER SERVICE
PIPE
CUT AND PLUG EXISTING WELL
PIPE WATER TIGHT AT
FOUNDATION INTERIOR
JT
JT
1/4" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
307 Main St.dwg
308 Main Street
N
60275749
JANUARY 2018
00 20' 40'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#308
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 20'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-308MAIN.dwg
CONTRACTOR TO
REMOVE EXISTING
WATER SYSTEM
COMPONENTS AND
PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL
PENETRATION
FOR NEW WATER
SERVICE PIPE
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
NEW WATER SERVICE PIPING AND COMPONENTS.
SEE DETAIL 1, SHEET C-503. PROVIDE FITTINGS AND
PIPING SUPPORTS AS NEEDED
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
308 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER
BOX AND HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS
UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL
FEED WIRES BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT
WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN
ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN
CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1,
SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS NEEDED
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CUT AND PLUG
EXISTING WELL
PIPE WATER
TIGHT AT
FOUNDATION
INTERIOR
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
308 Main St.dwg
312 Main Street
N
60275749
JANUARY 2018
00 20' 40'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#312
EXISTING WELL TO BE
ABANDONED AFTER THE NEW
WATER SERVICE IS INSTALLED
AND IN USE
INSTALL NEW WATER SERVICE
AND CURB STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 20'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-312MAIN.dwg
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING.
CONTRACTOR SHALL DISCONNECT
AND RELOCATE WATER SOFTENER
SYSTEM AS DIRECTED BY
HOMEOWNER.
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
60275749
JANUARY 2018
JT
JT
" = 1' - 0"
2 3
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
312 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO
MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO REMOVE EXISTING WATER
SYSTEM COMPONENTS AND PIPING.
CONTRACTOR SHALL DISCONNECT AND
RELOCATE WATER SOFTENER SYSTEM AS
DIRECTED BY HOMEOWNER.
CUT AND PLUG EXISTING WELL
PIPE WATER TIGHT AT FOUNDATION
INTERIOR
60275749
JANUARY 2018
JT
JT
" = 1' - 0"
3 3
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
312 Main St.dwg
313 Main Street
S T
A x x
M
J
C
L D
I
T
E
R
E S
T R
A I N
D
G
L A
N D
S
M
J
B
U T
T E
R F
Y
L V
R
E S
T R
A I N
A
N D
S
A
L V
E
B
O X
E S
M
J
G
A T
E
V
A L V
E
W
R
E S
T R
A I N
A
N D
S
A
L V
E
B
O X
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#313
EXISTING WELL TO BE ABANDONED
AFTER THE NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER SERVICE
AND CURB STOP - SEE DETAIL
DRAWING C-503
MC
MC
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
N
SER-DUR-313MAIN.dwg
OLD WELL TO BE
ABANDONED
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CONNECT TO EXISTING
COLD WATER FEED
PIPE
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
JT
JT
3/16" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
313 Main St..dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL
PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF ALL
MATERIALS UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX,
REMOVE ELECTRICAL FEED WIRES BACK TO
MAIN ELECTRICAL PANEL AND DISCONNECT
WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM
EXISTING MAIN ELECTRICAL PANEL TO NEW
WATER SERVICE. SIZE AND INSTALL IN
CONFORMANCE WITH ALL ELECTRICAL CODE
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE
PIPING AND COMPONENTS.
SEE DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER SYSTEM
COMPONENTS AND PIPING
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
JT
JT
1/4" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
313 Main St..dwg
316 Main Street
N
60275749
JANUARY 2018
00 20' 40'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#316
EXISTING WELL TO BE ABANDONED
AFTER THE NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER SERVICE
AND CURB STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 20'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-316MAIN.dwg
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER
TREATMENT SYSTEM
COMPONENTS AND PIPING
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS NEEDED
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
316 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE
WELL PUMP, WELL CONTROLLER BOX
AND HYDROPNEUMATIC TANK AND
DISPOSE OF ALL MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP
CONTROL BOX, REMOVE ELECTRICAL
FEED WIRES BACK TO MAIN
ELECTRICAL PANEL AND DISCONNECT
WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE
FROM EXISTING MAIN ELECTRICAL
PANEL TO NEW WATER SERVICE. SIZE
AND INSTALL IN CONFORMANCE WITH
ALL ELECTRICAL CODE
REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING
WATER TREATMENT SYSTEM
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CORE AND SEAL
PENETRATION
FOR NEW WATER
SERVICE PIPE
CUT AND PLUG EXISTING WELL
PIPE WATER TIGHT AT FOUNDATION
INTERIOR
CONTRACTOR TO
REMOVE EXISTING
WATER
TREATMENT
SYSTEM
COMPONENTS
AND PIPING
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
316 Main St.dwg
321 Main Street
R
E E
T
R
T E
M A
R
E E
T
R
T E
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#321
Durham Rx
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW
WATER SERVICE
AND CURB STOP -
SEE DETAIL
DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
N
SER-DUR-321MAIN.dwg
DRIVEWAY PAVEMENT
RESTORATION - SEE
DRAWING C-17
COMPONENTS AND PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING WELL PIPE
WATER TIGHT AT FOUNDATION INTERIOR
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
D u r h a m x
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
321 Main St Durham Rx.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL
PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF ALL
MATERIALS UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX,
REMOVE ELECTRICAL FEED WIRES BACK TO
MAIN ELECTRICAL PANEL AND DISCONNECT
WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM
EXISTING MAIN ELECTRICAL PANEL TO NEW
WATER SERVICE. SIZE AND INSTALL IN
COMPONENTS AND PIPING
CONNECT TO EXISTING COLD
WATER FEED PIPE
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
NEW WATER SERVICE
PIPING AND COMPONENTS.
SEE DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
SECTION A-A
A
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
D u r h m
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
321 Main St Durham Rx.dwg
SOUTH VIEW
322 Main Street
301+00
302+00
T A
L C
O T
T L
A N
E
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#322
EXISTING WELL TO BE
ABANDONED AFTER THE NEW
WATER SERVICE IS INSTALLED
AND IN USE
INSTALL NEW WATER SERVICE
AND CURB STOP - SEE DETAIL
DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
SER-DUR-322MAIN.dwg
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED.
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND
PIPING
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
N
322 Main St.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL
CONTROLLER BOX AND HYDROPNEUMATIC TANK AND
DISPOSE OF ALL MATERIALS UNLESS OTHERWISE
DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE
ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL
PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN
ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE AND
INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE
REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT
SYSTEM COMPONENTS IN ACCORDANCE WITH THE
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE
PIPING AND
COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER
TREATMENT SYSTEM
COMPONENTS AND PIPING
CUT AND PLUG
EXISTING WELL
PIPE WATER TIGHT
AT FOUNDATION
INTERIOR
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
322 Main St.dwg
325 Main Street
R
E E
T
R
T E
M A
R
E E
T
R
T E
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#325
EXISTING WELL TO BE ABANDONED
AFTER THE NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB STOP -
SEE DETAIL DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A
S I T
E
P
L A
N
SER-DUR-325MAIN.dwg
DRIVEWAY PAVEMENT
RESTORATION - SEE
DRAWING C-17
EXISTING WATER
TREATMENT SYSTEM
COMPONENTS AND PIPING
NEW WATER SERVICE
PIPING AND
COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
A
NV
NV
" = 1' - 0"
2 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
325 Main Street.dwg
N
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE
DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES
BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL
TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL
ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS
IN ACCORDANCE WITH THE SPECIFICATIONS.
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1,
SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS NEEDED.
CONNECT TO EXISTING
COLD WATER FEED PIPE
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING.
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
SECTION A-A
A
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
NV
NV
" = 1' - 0"
3 3
T O
D
U R
H A
M
M
A
R
E E
T
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
325 Main Street.dwg
7 Maple Avenue
B
A
N
D
O
N
E
X
I S
T
I N
G
W
E
L
L
T
Y
P
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#7
PROPERTY IS
ALREADY
CONNECTED TO
THE WATER
SYSTEM ON MAIN
STREET.
MC
MC
1" = 40'
1 1
T O
D
U R
H A
M
M
A P
E
S I T
E
P
L A
N
SER-DUR-7MAPLE.dwg
EXISTING WELL TO BE
ABANDONED. LOCATION
OF WELL TO BE
DETERMINED IN FIELD
13 Maple Avenue
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#13
EXISTING WELL TO BE ABANDONED
AFTER NEW WATER SERVICE IS
INSTALLED AND IN USE.
MC
MC
1" = 40'
1 3
T O
D
U R
H A
M
M
A P
E
S I T
E
P
L A
N
SER-DUR-13MAPLE.dwg
INSTALL NEW WATER SERVICE AND
CURB STOP - SEE DETAIL DRAWING
C-503. LOCATION TO BE VERIFIED
WITH THE OWNER.
CONTRACTOR TO AVOID
STONE PATIO WHEN
WELL IS ABANDONED.
CONTRACTOR TO REMOVE
EXISTING WATER
TREATMENT SYSTEM
COMPONENTS AND PIPING.
CONTRACTOR SHALL
DISCONNECT AND
RELOCATE WATER
SOFTENER SYSTEM AS
DIRECTED BY HOMEOWNER.
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE DETAIL
1, SHEET C-503. PROVIDE
FITTINGS AND PIPING SUPPORTS
AS NEEDED
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
SUPPORT PIPE
ALONG CEILING
JT
JT
1/8" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
N
13 Maple Ave.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE
WELL PUMP, WELL CONTROLLER BOX
AND HYDROPNEUMATIC TANK AND
DISPOSE OF ALL MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP
CONTROL BOX, REMOVE ELECTRICAL
FEED WIRES BACK TO MAIN
ELECTRICAL PANEL AND DISCONNECT
WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE
FROM EXISTING MAIN ELECTRICAL
PANEL TO NEW WATER SERVICE. SIZE
AND INSTALL IN CONFORMANCE WITH
ALL ELECTRICAL CODE
REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING
WATER TREATMENT SYSTEM
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE
PIPING AND
COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
CORE AND SEAL
PENETRATION
FOR NEW WATER
SERVICE PIPE
CONTRACTOR TO
REMOVE EXISTING
WATER TREATMENT
SYSTEM COMPONENTS
AND PIPING.
CONTRACTOR SHALL
DISCONNECT AND
RELOCATE WATER
SOFTENER SYSTEM AS
DIRECTED BY
HOMEOWNER.
CUT AND PLUG EXISTING WELL
PIPE WATER TIGHT AT FOUNDATION
INTERIOR
JT
JT
1/4" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
13 Maple Ave.dwg
29 Maple Avenue
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#29
EXISTING WELL TO BE
ABANDONED AFTER THE
NEW WATER SERVICE IS
INSTALLED AND IN USE
PROPERTY HAS A CAPPED WATER
CONNECTION ON THE SOUTH SIDE OF
THE PROPERTY. EXTEND WATER
SERVICE FROM THE EXISTING WATER
SERVICE - SEE DETAIL DRAWING C-503
MC
MC
1" = 40'
1 1
T O
D
U R
H A
M
M
A P
E
S I T
E
P
L A
SER-DUR-29MAPLE.dwg
CONTRACTOR TO
REMOVE EXISTING
WATER SYSTEM
COMPONENTS AND
PIPING
CONNECT TO EXISTING
COLD WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG
EXISTING WELL
PIPE WATER
TIGHT AT
FOUNDATION
INTERIOR
JT
JT
1/8" = 1' - 0"
1 2
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
29 Maple Ave.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE
DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO
MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW
REQUIREMENTS
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1,
SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS
NEEDED
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO REMOVE EXISTING
WATER SYSTEM COMPONENTS AND
PIPING
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
JT
JT
1/8" = 1' - 0"
2 2
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
29 Maple Ave.dwg
41 Maple Avenue
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. IF IT STILL REMAINS, EXISTING WELL SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND
CAPPED WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#41
EXISTING WELL TO BE
ABANDONED (CURRENTLY
NOT IN USE)
PROPERTY IS ALREADY
CONNECTED TO THE
EXISTING WATER SYSTEM
MC
MC
1" = 40'
1 1
T O
D
U R
H A
M
M
A P
E
S I T
E
P
L A
SER-DUR-41MAPLE.dwg
95R Maple Avenue
M
60275749
APRIL 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO LOCATE AND AVOID UNDERGROUND ELECTRICAL AND CABLE FROM MAIN
STREET TO HOUSE.
2. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
3. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
4. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
5. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#95R
EXISTING WELL TO BE
ABANDONED AFTER THE NEW
WATER SERVICE IS INSTALLED
AND IN USE
INSTALL NEW 2" WATER SERVICE
AND CURB STOP - SEE DETAIL
DRAWING C-503
MC
MC
1" = 40'
1 3
T O
D
U R
H A
M
P
E
S I T
E
P
L A
N
SER-DUR-95RMAPLE.dwg
INSTALL WATER METER
PIT - SEE DETAIL DRAWING
C-503
M
A
2" TYPE K COPPER
WATER SERVICE
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING
CONNECT TO
EXISTING COLD
WATER FEED PIPE
CORE AND SEAL
PENETRATION
FOR NEW WATER
SERVICE PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING WELL
PIPE WATER TIGHT AT
FOUNDATION INTERIOR
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
95R Maple Avenue.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE
WELL PUMP, WELL CONTROLLER BOX AND
HYDROPNEUMATIC TANK AND DISPOSE OF
ALL MATERIALS UNLESS OTHERWISE
DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL
BOX, REMOVE ELECTRICAL FEED WIRES
BACK TO MAIN ELECTRICAL PANEL AND
DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE
FROM EXISTING MAIN ELECTRICAL PANEL
TO NEW WATER SERVICE. SIZE AND
INSTALL IN CONFORMANCE WITH ALL
ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING
WATER TREATMENT SYSTEM
COMPONENTS IN ACCORDANCE WITH THE
CONNECT TO
EXISTING COLD
WATER FEED PIPE
CORE AND SEAL PENETRATION
FOR NEW WATER SERVICE PIPE
CUT AND PLUG EXISTING WELL PIPE
WATER TIGHT AT FOUNDATION INTERIOR
NEW WATER SERVICE PIPING AND COMPONENTS.
SEE DETAIL 1, SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS NEEDED
CONTRACTOR TO
REMOVE EXISTING
WATER TREATMENT
SYSTEM
COMPONENTS AND
PIPING
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
95R Maple Avenue.dwg
97R MAPLE AVENUE
P
E
M
M A
P
E
N
60275749
APRIL 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#97R
EXISTING WELL TO BE ABANDONED
AFTER THE NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW 1-1/2"
WATER SERVICE AND
CURB STOP - SEE
DETAIL DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
P
E
S I T
E
P
L A
N
SER-DUR-97RMAPLE.dwg
INSTALL WATER METER PIT - SEE
DETAIL DRAWING C-503
1-1/2" TYPE K
COPPER
WATER
CONTRACTOR
TO REMOVE
EXISTING
WATER
TREATMENT
SYSTEM
COMPONENTS
AND PIPING
CONNECT TO
EXISTING COLD
WATER FEED PIPE
CORE AND SEAL
PENETRATION FOR
NEW WATER
SERVICE PIPE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
A
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
P
E
N U
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
97R Maple Avenue.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL
CONTROLLER BOX AND HYDROPNEUMATIC TANK AND
DISPOSE OF ALL MATERIALS UNLESS OTHERWISE
DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE
ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL
PANEL AND DISCONNECT WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING
MAIN ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE
AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL
CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT
SYSTEM COMPONENTS IN ACCORDANCE WITH THE
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND PIPING SUPPORTS
AS NEEDED
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
SECTION A-A
A
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
P
E
N U
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
97R Maple Avenue.dwg
109 Maple Avenue
M
N
60275749
APRIL 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSAL OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#109
EXISTING WELL TO BE ABANDONED
AFTER THE NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW 2"
WATER SERVICE
AND CURB STOP -
SEE DETAIL
DRAWING C-503
JT
JT
1" = 40'
1 3
T O
D
U R
H A
M
M
A P
E
S I T
E
P
L A
N
SER-DUR-109MAPLE.dwg
INSTALL WATER METER PIT - SEE
DETAIL DRAWING C-503
2" TYPE K COPPER
WATER SERVICE
COLD WATER FEED
PIPE
NEW WATER SERVICE PIPING
AND COMPONENTS. SEE
DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED.
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT
AT FOUNDATION INTERIOR
CONTRACTOR TO
REMOVE EXISTING
WATER TREATMENT
SYSTEM COMPONENTS
AND PIPING
A
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
JT
JT
" = 1' - 0"
2 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
109 Maple Ave.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER
BOX AND HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS
UNLESS OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL
FEED WIRES BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT
WIRES FROM PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL
PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE
WITH ALL ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM
COMPONENTS IN ACCORDANCE WITH THE SPECIFICATIONS.
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1,
SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS
NEEDED
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND
PIPING
SECTION A-A
A
JT
JT
" = 1' - 0"
3 3
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
109 Maple Ave.dwg
110 Maple Avenue
M
M g i l i n
P o l e
N
60275749
JANUARY 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#110
EXISTING WELL TO BE ABANDONED
AFTER THE NEW WATER SERVICE IS
INSTALLED AND IN USE
INSTALL NEW WATER
SERVICE AND CURB
STOP - SEE DETAIL
DRAWING C-503.
MC
MC
1" = 40'
1 4
T O
D
U R
H A
M
M
A P
E
S I T
E
P
L A
SER-DUR-110MAPLE.dwg
B
CUT AND PLUG
EXISTING WELL PIPE
WATER TIGHT AT
FOUNDATION INTERIOR
NEW WATER SERVICE PIPING AND
COMPONENTS. SEE DETAIL 1, SHEET
C-503. PROVIDE FITTINGS AND PIPING
SUPPORTS AS NEEDED
CONNECT TO EXISTING
COLD WATER FEED PIPE
CONTRACTOR TO
REMOVE EXISTING
WATER TREATMENT
SYSTEM COMPONENTS
AND PIPING
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
JT
JT
" = 1' - 0"
2 4
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
P L
E
W
110 Maple Ave.dwg
NOTES:
1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP,
WELL CONTROLLER BOX AND HYDROPNEUMATIC
TANK AND DISPOSE OF ALL MATERIALS UNLESS
OTHERWISE DIRECTED.
2. DISCONNECT EXISTING PUMP CONTROL BOX,
REMOVE ELECTRICAL FEED WIRES BACK TO MAIN
ELECTRICAL PANEL AND DISCONNECT WIRES FROM
PANEL.
3. INSTALL NEW COPPER BONDING WIRE FROM
EXISTING MAIN ELECTRICAL PANEL TO NEW WATER
SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH
ALL ELECTRICAL CODE REQUIREMENTS.
4. REMOVE AND DISPOSE OF EXISTING WATER
TREATMENT SYSTEM COMPONENTS IN
ACCORDANCE WITH THE SPECIFICATIONS.
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO
REMOVE EXISTING
WATER TREATMENT
SYSTEM COMPONENTS
AND PIPING
CUT AND PLUG EXISTING WELL PIPE
WATER TIGHT AT FOUNDATION
INTERIOR
CONNECT TO EXISTING COLD WATER FEED PIPE
NEW WATER SERVICE
PIPING AND COMPONENTS.
SEE DETAIL 1, SHEET C-503.
PROVIDE FITTINGS AND
PIPING SUPPORTS AS
NEEDED
JT
JT
3 4
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
110 Maple Ave.dwg
SOUTH VIEW
" = 1' - 0"
SECTION B-B
M
CORE AND SEAL
PENETRATION FOR NEW
WATER SERVICE PIPE
CONTRACTOR TO REMOVE
EXISTING WATER TREATMENT
SYSTEM COMPONENTS AND PIPING
CUT AND PLUG EXISTING
WELL PIPE WATER TIGHT AT
FOUNDATION INTERIOR
CONNECT TO EXISTING
COLD WATER FEED PIPE
NEW WATER SERVICE PIPING AND COMPONENTS.
SEE DETAIL 1, SHEET C-503. PROVIDE FITTINGS
AND PIPING SUPPORTS AS NEEDED
JT
JT
4 4
60275749
JANUARY 2018
T O
D
U R
H A
M
M
A P
E
I N
T E
R I O
R
S
E R
V I C
E
C
O N
N E
C T
I O
N S
E L
E V
A T
I O
N
V
I E
W
110 Maple Ave.dwg
WEST VIEW
" = 1' - 0"
Page intentionally left blank
119 Maple Avenue
J
L
V
E
S
T
R
A
I
N
A
N
L
X
M
M
A
S
T
N
U
L
E
A
L
V
E
S
T
A
H
E
C
N
60275749
APRIL 2018
00 40' 80'
NOTES:
1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.
2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.
3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED
WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.
4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE
DIRECTED.
#119
EXISTING WELL TO BE ABANDONED AFTER THE
NEW…