Volume_2_Appendix_B_pages_208_to_400.pdf

PDF 9 MB Posted

Attached to
New Water Distribution System in Durham and Middletown, Connecticut
Solicitation number
W912WJ18B0016
Issued by

About this file

Volume 2 208-400

View the file

Other files

File Type Posted
Bid_Abstract-signed.pdf PDF
Bid_Snapsheet.pdf PDF
Amendment_0006_-_Durham_Spec_Section_11355_Revised_15_Aug_2018.pdf PDF
Amendment_0006_-_Durham_Sheet_E3_Revised_15_Aug_2018.pdf PDF
Amendment_0006_-_Durham_Sheet_E4_Revised_15_Aug_2018.pdf PDF
Amendment_0006.pdf PDF
Amendment_0005_-_19_Maiden_Lane_Amendment.pdf PDF
Volume_2_Appendix_B_pages_401_to_600.pdf PDF
Amendment_0005_.pdf PDF
Volume_2_Appendix_C_pages_687_to_688.pdf PDF
Amendment_0005_-_Updated_Specifications.pdf PDF
Amendment_0005_-_C-505_Bid_Amendment.pdf PDF
Volume_2_Appendix_B_pages_601_to_686.pdf PDF
Volume_2_Appendix_D_pages_689_to_696.pdf PDF
Amendment_0005_-_C-4_Bid_Amendment.pdf PDF
Volume_2_Appendix_A_pages_1_to_207.pdf PDF
Amendment_0004.pdf PDF
Amendment_0003.pdf PDF
Amendment_0003_-_Change_to_Specifications.pdf PDF
Amendment_0002.pdf PDF
Amendment_0001.pdf PDF
Durham_BasisOfDesignReport_25Apr18.pdf PDF
Durham_Waterline_BODR_Appendices_25_April_2018.pdf PDF
Specifications.pdf PDF
Specs_Vol_2_Durham_Appendix_10_May_2018_Final.pdf PDF
Plans_Durham_Meadows_Waterline_10_May_2018_Final.pdf PDF
W912WJ18B0016.pdf PDF
Specs_Vol_1_Durham_Waterline_10_May_2018_Final.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX B

Water Service Work on Private Property

Details by Address

Page intentionally left blank

Drawing

Town Assessor's

Map Number Address

Residential, Commercial or Undeveloped

Water Service to Curb Stop only

Water Service Installation

(Including Meter)

Meter Pit Required

Well to be Abandoned

C‐13 16 472 Main Street Retail Yes No No No C‐13 16 475 Main Street Residential Yes No No No C‐13 16 478R Main Street Residential Yes No No No C‐13 6 484 Main Street Residential Yes No No No C‐13 6 490 Main Street Residential Yes No No No C‐13 6 514 Main Street (See Middlefield below) Undeveloped Yes No No No C‐13 6 112 Oak Terrace Residential Yes No No No C‐13 6 136 Oak Terrace Residential Yes No No No C‐13 6 7 Royal Oak Drive Residential Yes No No No C‐13 6 12 Royal Oak Drive Residential Yes No No No C‐13 6 18R Packinghouse Hill Road Residential Yes No No No C‐15 27 363 Main Street (service on Haddam Qtr Rd) Commercial Yes No No No C‐15 27 376 Main Street Commercial Yes No No No C‐15 16 384 Main Street (1) Commercial Yes No No No C‐15 16 385 Main Street (1) Residential Yes No No No C‐15 16 391 Main Street (1) Residential Yes No No No C‐15 16 395 Main Street (1) Residential Yes No No No C‐15 16 397 Main Street (1) Residential Yes No No No C‐15 16 407 Main Street (1) Residential Yes No No No C‐15 16 413 Main Street (1) Residential Yes No No No C‐15 16 417 Main Street (1) Residential Yes No No No C‐15 16 422 Main Street (1) Commercial Yes No No No C‐15 16 423 Main Street (1) Residential Yes No No No C‐15 16 425 Main Street Residential Yes No No No C‐15 16 428 Main Street Commercial Yes No No No C‐15 16 431 Main Street Residential Yes No No No C‐15 16 435 Main Street Residential Yes No No No C‐15 16 437 Main Street Residential Yes No No No C‐15 16 441 Main Street Residential Yes No No No C‐15 16 447 Main Street Residential Yes No No No C‐15 16 448 Main Street Commercial Yes No No No C‐15 16 454 Main Street Commercial Yes No No No C‐15 16 457 Main Street Residential Yes No No No C‐15 16 459 Main Street Residential Yes No No No C‐15 16 460 Main Street Residential Yes No No No C‐15 16 465 Main Street Residential Yes No No No C‐15 27 Map 27, Lot 17 Undeveloped Yes No No No C‐15 16 Map 16, Lot 2 (1) Undeveloped Yes No No No C‐15 16 Map 16, Lot 14 Undeveloped Yes No No No C‐15 16 13 Middlefield Road (1) Residential Yes ‐ 2 No No No C‐15 16 35 Winsome Road (1) Commercial Yes No No No C‐17 27 313 Main Street Residential No Yes No Yes ‐ 2 C‐17 27 316 Main Street Residential No Yes No Yes C‐17 27 321 Main Street Commercial No Yes No Yes C‐17 27 322 Main Street Residential No Yes No Yes C‐17 27 325 Main Street Commercial No Yes No Yes C‐17 27 327 Main Street Commercial Yes No No No C‐17 27 328 Main Street (service on Talcott La.) Residential Yes No No No C‐17 27 336 Main Street Commercial Yes No No No C‐17 27 339 Main Street Commercial Yes No No No C‐17 27 349 Main Street Commercial Yes No No No C‐17 27 350 Main Street Commercial Yes ‐ 3 No No No C‐17 27 357 Main Street Commercial Yes No No No C‐17 27 360 Main Street Commercial Yes No No No C‐19 38 257 Main Street Residential No Yes No Yes C‐19 38 261 Main Street Residential No Yes Yes Yes C‐19 38 262 Main Street Residential No Yes No Yes C‐19 38 265 Main Street Residential No Yes No Yes C‐19 38 267 Main Street Residential No Yes No Yes C‐19 38 268 Main Street Residential No Yes No Yes C‐19 38 271 Main Street Residential No Yes No Yes C‐19 38 272 Main Street Commercial No Yes No Yes C‐19 38 275 Main Street (2) Residential No Yes No No C‐19 38 280 Main Street Commercial No Yes Yes Yes C‐19 38 281R Main Street Undeveloped Yes No No No C‐19 27 281 Main Street Undeveloped Yes No No No C‐19 27 289 Main Street Residential No Yes No Yes C‐19 27 293 Main Street Residential No Yes No Yes C‐19 27 297 Main Street Residential No Yes No Yes

Durham Meadows Waterline RD Summary of All Properties within EPA Contract No. EP‐S1‐06‐01

Durham

Assessor's

Map Number Address

Residential, Commercial or Undeveloped

Water Service to Curb Stop only

Water Service Installation

(Including Meter)

Meter Pit Required

Well to be Abandoned

Durham Meadows Waterline RD Summary of All Properties within EPA Contract No. EP‐S1‐06‐01

C‐19 38 298 Main Street (3) Residential Yes Yes No Yes C‐19 27 303 Main Street Residential No Yes No Yes C‐19 27 305R Main Street Residential No Yes Yes Yes C‐19 27 307 Main Street Residential No Yes No Yes C‐19 38 308 Main Street Residential No Yes No Yes C‐19 38 312 Main Street Residential No Yes No Yes C‐21 38 205 Main Street Commercial No Yes No Yes C‐21 38 203R Main Street (4) Commercial No Yes Yes 2; Convert 1 to Monitoring Well C‐21 38 208 Main Street Residential No Yes No Yes C‐21 38 215 Main Street Residential No Yes No Yes C‐21 38 216 Main Street Residential No Yes No Yes C‐21 38 220 Main Street Residential No Yes No Yes C‐21 38 227 Main Street Residential No Yes No Yes C‐21 38 228 Main Street Commercial No Yes No Yes C‐21 38 228R Main Street Commercial No Yes No Shares well at 228 Main C‐21 38 233 Main Street Residential No Yes No Yes C‐21 38 235 Main Street Residential No Yes No Shares well at 233 main C‐21 38 236 Main Street Commercial No Yes No Yes C‐21 38 238 Main Street Commercial No Yes No Yes C‐21 38 239 Main Street Residential No Yes No Yes C‐21 38 242 Main Street Residential No Yes No Yes C‐21 38 243 Main Street Commercial No Yes No Yes C‐21 38 246 Main Street Residential No Yes No Yes C‐21 38 248 Main Street Residential No Yes No Yes C‐21 38 252 Main Street Residential No Yes No Yes C‐21 38 253 Main Street Residential No Yes No Yes C‐21 38 256 Main Street Residential No Yes No Yes C‐21 38 Map 38 Lot 24 Main Street Undeveloped Yes No No No C‐21 38 11 Maiden Residential No Yes No Yes C‐21 38 17 Maiden Residential No Yes No Yes C‐23 48 167 Main Street Residential No Yes No Yes C‐23 48 168 Main Street Residential No Yes No Yes C‐23 48 174 Main Street Undeveloped (5) Yes No No Yes C‐23 48 175R Main Street Residential No Yes Yes Yes C‐23 48 176 Main Street Residential No Yes No Yes C‐23 48 177R Main Street Residential No Yes No Yes C‐23 38 186 Main Street Residential No Yes No Yes C‐23 38 188 Main Street Residential No Yes No Yes C‐23 38 196 Main Street Commercial No Yes Yes Yes C‐23 38 199 Main Street Commercial No Yes No No C‐23 38 201 Main Street Commercial No Yes No No C‐23 38 202 Main Street Residential No Yes No Yes C‐23 48 Map 48 Lot 31 Main Street Undeveloped Yes No No No C‐25 48 119 Main Street Residential No Yes No Yes C‐25 48 120 Main Street Residential No Yes No Yes C‐25 48 127 Main Street Residential No Yes No Yes C‐25 48 128 Main Street Residential No No No No C‐25 48 133 Main Street Residential No No No No C‐25 48 151R Main Street Residential No Yes Yes No (6)

C‐25 48 153 Main Street Residential No Yes No Yes C‐25 48 Mill Pond Road Residential No No No 3 Total: Yes 2, Convert 1 (4)

C‐27 48 22 John's Way Residential No No No No C‐27 48 7 Maple Avenue Residential No No No Yes C‐27 48 13 Maple Avenue Residential No Yes No Yes ‐ 2 C‐27 48 29 Maple Avenue Residential No Yes No Yes C‐27 48 41 Maple Avenue Residential No No No Yes C‐27 48 10 John's Way Residential No Yes Yes Yes C‐27 48 17 John's Way Residential No No No Yes C‐27 48 30 Town House Road Commercial No No No Yes ‐ 2

C‐27/M‐111 48 Map 48, Lot 6 (Durham Fairgrounds) Commercial No No No 2 Total: Yes 1, Convert 1 (4)

C‐29 48 110 Maple Avenue Residential No Yes No Yes C‐29 48 95R Maple Avenue Residential No Yes Yes Yes C‐29 48 97R Maple Avenue Residential No Yes Yes Yes C‐29 38 109 Maple Avenue Residential No Yes Yes Yes C‐31 38 119 Maple Avenue Residential No Yes Yes Yes C‐31 38 126 Maple Avenue Residential No Yes No Yes C‐31 38 129 Maple Avenue Residential No Yes Yes No, uses well from church C‐31 38 133 Maple Avenue Residential No Yes No Yes C‐31 38 139 Maple Avenue Residential Yes No No No C‐31 37 146 Maple Avenue Residential No Yes No Yes

Assessor's

Map Number Address

Residential, Commercial or Undeveloped

Water Service to Curb Stop only

Water Service Installation

(Including Meter)

Meter Pit Required

Well to be Abandoned

Durham Meadows Waterline RD Summary of All Properties within EPA Contract No. EP‐S1‐06‐01

C‐31 37 148 Maple Avenue Residential No Yes No Yes C‐31 37 158 Maple Avenue Residential No Yes No Yes C‐31 37 162 Maple Avenue Residential No Yes No Yes C‐31 38 17 Wallingford Road Residential No Yes No Yes C‐31 38 22 Wallingford Road Residential No Yes Yes Yes C‐31 37 47 Wallingford Road Residential No Yes No Yes C‐31 37 Map 37, Lot 15 Undeveloped Yes No No Yes C‐33 37 166 Maple Avenue Residential No Yes No Yes C‐33 37 172 Maple Avenue Residential No Yes No Yes C‐33 38 173 Maple Avenue Residential No Yes No Yes C‐33 38 175 Maple Avenue Residential No Yes No Yes C‐33 37 176 Maple Avenue Residential No Yes No Yes C‐33 37 184 Maple Avenue Residential No Yes No Yes C‐33 38 187 Maple Avenue Residential No Yes No Yes C‐33 37 188 Maple Avenue Residential No Yes No Yes C‐33 37 200 Maple Avenue Residential No Yes No Yes C‐33 37 206 Maple Avenue Residential No Yes No Yes C‐33 37 212R Maple Avenue Residential No Yes Yes Yes C‐35 26 214R Maple Avenue Undeveloped Yes No No No C‐35 27 224 Maple Avenue Residential No Yes Yes Yes C‐35 26 228R Maple Avenue Residential No Yes Yes Yes C‐35 26 230 Maple Avenue Residential No Yes Yes Yes C‐35 27 235 Maple Avenue Residential No Yes No Yes C‐35 26 236 Maple Avenue Residential No Yes No Yes C‐35 26 244 Maple Avenue Residential No Yes No Yes C‐35 27 245 Maple Avenue Residential No Yes No Yes C‐35 26 254 Maple Avenue Residential No Yes No Yes C‐35 26 14 Talcott Lane Residential No Yes Yes Yes C‐35 26 25 Talcott Lane Residential No Yes No Yes C‐35 27 Map 27, Lot 8 Undeveloped Yes ‐ 3 No No Yes C‐37 38 18 Maiden Lane Residential No Yes No Yes C‐37 38 19 Maiden Lane Residential No Yes No Yes C‐37 38 24 Maiden Lane Residential No Yes No Yes C‐37 38 29 Maiden Lane Residential No Yes No Yes C‐37 38 35 Maiden Lane Residential No Yes No Yes C‐37 38 36 Maiden Lane Residential No Yes No Yes C‐39 38 63 Maiden Lane Residential No Yes No Yes C‐39 38 78 Maiden Lane Residential No Yes No Yes C‐39 38 96 Maiden Lane Undeveloped Yes No No No C‐39 38 105 Maiden Lane Residential No Yes No Yes C‐39 38 110 Maiden Lane Residential No Yes No Yes C‐39 38 114R Maiden Lane Residential No Yes Yes Yes C‐39 38 Map 39, Lot 35 Undeveloped Yes No No No C‐39 38 Map 39, Lot 34.1 Undeveloped Yes No No No C‐39 38 Map 38, Lot 29 Undeveloped Yes No No No C‐39 39 123 Maiden Lane Residential No Yes No Yes C‐41 38 191 Main Street Strong School C‐41 48 191 Main Street (south of Pickett Lane) Korn school Yes No No Yes C‐41 38 Map 38, Lot 51 Pickett Lane near cochnuag hs Yes No No Convert to Monitoring Well (4)

C‐41 38 Map 38, Lot 51 Pickett Lane North & East of Tennis Courts No No No Yes ‐ 2

C‐41 38 Map 38, Lot 51 Pickett Lane East of Tennis Courts Yes No No Yes C‐41 38 191 Main Street (south of Pickett Lane) Soccer fields

C‐43 38 191 Main Street (south of Pickett Lane) Basketball Courts

C‐43 38 191 Main Street (East of Pickett Lane) High School C‐43 38 191 Main Street (West of Pickett Lane) Korn School C‐43 38 93R Maiden Lane (Service on Pickett La.) Residential No Yes No Yes

Middletown C‐3 32 214 Talcott Ridge Drive Residential Yes No No No C‐3 32 216 Talcott Ridge Drive Residential Yes No No No C‐3 32 224 Talcott Ridge Drive Residential Yes No No No C‐5 32 182 Talcott Ridge Drive Residential No No No No C‐5 32 199 Talcott Ridge Drive Residential No No No No C‐5 32 204 Talcott Ridge Drive Undeveloped Yes No No No C‐7 32 164 Talcott Ridge Drive Residential No No No No C‐7 32 8 Watch Hill Drive Residential No No No No C‐7 32 82 Watch Hill Drive Residential No No No No C‐7 32 68 Talcott Ridge Drive Residential No No No No C‐7 32 83 Talcott Ridge Drive Residential No No No No C‐7 32 88 Talcott Ridge Drive Undeveloped Yes No No No C‐7 32 105 Talcott Ridge Drive Residential No No No No

Tie into existing fire and domestic services

Connect to existing service, meter and backflow preventer required Connect to existing service, meter and backflow preventer required Tie into existing fire and domestic services Tie into existing fire and domestic services

Assessor's

Map Number Address

Residential, Commercial or Undeveloped

Water Service to Curb Stop only

Water Service Installation

(Including Meter)

Meter Pit Required

Well to be Abandoned

Durham Meadows Waterline RD Summary of All Properties within EPA Contract No. EP‐S1‐06‐01

C‐7 32 108 Talcott Ridge Drive Undeveloped Yes No No No C‐7 32 124 Talcott Ridge Drive Residential No No No No C‐7 32 142 Talcott Ridge Drive Residential No No No No C‐9 32 Map 32, Lot 8 South Main St St. of CT No No No No C‐9 32 2156 South Main Street Residential Yes No No No C‐9 32 9 Talcott Ridge Drive Residential No No No No C‐9 32 18 Talcott Ridge Drive Undeveloped Yes No No No C‐9 32 33 Talcott Ridge Drive Residential No No No No C‐9 32 48 Talcott Ridge Drive Residential No No No No

C‐11 32 2155 South Main Street Residential Yes No No No C‐11 32 2175 South Main Street Commercial Yes No No No C‐11 32 2200 South Main Street Undeveloped Yes No No No C‐11 32 2286 South Main Street Residential Yes No No No C‐11 32 2292 South Main Street Residential Yes No No No C‐11 32 2296 South Main Street Residential Yes No No No C‐11 32 2330 South Main Street Residential Yes No No No C‐11 32 2332 South Main Street Residential Yes No No No C‐11 32 2301 South Main Street Commercial Yes No No No C‐11 32 2303 South Main Street Commercial Yes No No No C‐11 32 2329 South Main Street Residential Yes No No No C‐11 32 2337 South Main Street Residential Yes No No No C‐11 32 2345 South Main Street Residential Yes No No No C‐11 32 Map 32 Lot 48 Municipal C‐11 32 Map 32 Lot 55 Undeveloped Yes (2) No No No

C‐13 21 Route 17 (See 514 Main Street Durham) Undeveloped Yes No No No

(1) Pressure Reducing Valve required upon connection (future)

(2) Existing monitoring well at 275 Main Street to remain.

(3) There is a proposed lot split for 298 Main Street. An additional water service to the curb stop is shown.

(4) Four wells as noted will be converted to monitoring wells as specified under Section 02521. Note, the specific well to be converted for monitoring at RSD13 is TBD and will be identified by Owner.

(5) House at #174 Main Street was demolished, but well is still on site

(6) One well currently serves 151R and 153 Main Street

Middlefield

No ‐ location of water meter vault

ADDRESS DRAWING No. COMMENT

1 10 John's Way C‐27

2 17 John's Way C‐27 Property already connected to water service, well to be abandoned.

3 119 Main Street C‐25

4 120 Main Street C‐25

5 127 Main Street C‐25

6 151R Main Street C‐25

7 153 Main Street C‐25

8 167 Main Street C‐23

9 168 Main Street C‐23

10 175R Main Street C‐23

11 176 Main Street C‐23

12 177R Main Street C‐23

13 186 Main Street C‐23

14 188 Main Street C‐23

15 196 Main Street C‐23

16 199 Main Street C‐23

17 201 Main Street C‐23

18 202 Main Street C‐23

19 203 Main Street C‐21

20 205 Main Street C‐21

21 208 Main Street C‐21

22 215 Main Street C‐21

23 216 Main Street C‐21

24 220 Main Street C‐21

25 227/227A Main Street C‐21

26 233 Main Street C‐21

27 235 Main Street C‐21

28 228/228R Main Street C‐21

29 236 Main Street C‐21

30 238 Main Street C‐21

31 239 Main Street C‐21

32 242 Main Street C‐21

33 243 Main Street C‐21

34 246 Main Street C‐21

35 248 Main Street C‐21

36 252 Main Street C‐21

37 253 Main Street C‐21

38 256 Main Street C‐21

39 257 Main Street C‐19

40 261 Main Street C‐19

41 262 Main Street C‐19

Summary of Water Service Work on Private Property

42 265 Main Street C‐19

43 267 Main Street C‐19

44 268 Main Street C‐19

45 271 Main Street C‐19

46 272 Main Street C‐19

47 275 Main Street C‐19

48 280 Main Street C‐19

49 289 Main Street C‐19

50 293 Main Street C‐19

51 297 Main Street C‐19

52 298 Main Street C‐19 Additional Water Service to street line was added due to proposed lot split

53 305R Main Street C‐19

54 303 Main Street C‐19

55 307 Main Street C‐19

56 308 Main Street C‐19

57 312 Main Street C‐19

58 313 Main Street C‐17

59 316 Main Street C‐17

60 321 Main Street C‐17

61 322 Main Street C‐17

62 325 Main Street C‐17

63 7 Maple Avenue C‐25 Already Connected to Water System, Well to be Abandoned

64 13 Maple Avenue C‐27 Water Service available at property line

65 29 Maple Avenue C‐27

66 41 Maple Avenue C‐27 Already Connected to Water System, Well to be Abandoned

67 95R Maple Avenue C‐29

68 97R Maple Avenue C‐29

69 109 Maple Avenue C‐29

70 110 Maple Avenue C‐29

71 119 Maple Avenue C‐31

72 126 Maple Avenue C‐31 No Permission to Access Property, interior information not available

73 129 Maple Avenue C‐31

74 133 Maple Avenue C‐31

75 139 Maple Avenue C‐31

76 146 Maple Avenue C‐31

77 148 Maple Avenue C‐31

78 158 Maple Avenue C‐31

79 162 Maple Avenue C‐31

80 166 Maple Avenue C‐33

81 172 Maple Avenue C‐33

82 173 Maple Avenue C‐33

83 175 Maple Avenue C‐33

84 176 Maple Avenue C‐33

85 184 Maple Avenue C‐33

86 187 Maple Avenue C‐33

87 188 Maple Avenue C‐33

88 200 Maple Avenue C‐33

89 206 Maple Avenue C‐33

90 212R Maple Avenue C‐33

91 224 Maple Avenue C‐35 No Permission to Access Property, interior information not available

92 228R Maple Avenue C‐35 No Permission to Access Property, interior information not available

93 230 Maple Avenue C‐35

94 235 Maple Avenue C‐35

95 236 Maple Avenue C‐35 No Permission to Access Property, interior information not available

96 244 Maple Avenue C‐35

97 245 Maple Avenue C‐35

98 254 Maple Avenue C‐35

99 11 Maiden Lane C‐21

100 17 Maiden Lane C‐21

101 18 Maiden Lane C‐37

102 19 Maiden Lane C‐37

103 24 Maiden Lane C‐37

104 29 Maiden Lane C‐37

105 35 Maiden Lane C‐37

106 36 Maiden Lane C‐37

107 63 Maiden Lane C‐39 No Permission to Access Property, interior information not available

108 78 Maiden Lane C‐39

109 93R Maiden Lane C‐39

110 105 Maiden Lane C‐39

111 110 Maiden Lane C‐39

112 114R Maiden Lane C‐39

113 123 Maiden Lane C‐39

114 17 Wallingford Road C‐31

115 22 Wallingford Road C‐31

116 47 Wallingford Road C‐31

117 14 Talcott Lane C‐35

118 25 Talcott Lane C‐35

10 John’s Way

S

T

A

M

J

C

L

D

I

B

E

N

D

W

R

E

S

T

R

A

I N

E

G

L

A

N

D

S

S

T

A x x

M

J

C

L

D

I

W

Y

R

E

S

T

R

A

I N

A

N

D

S

M

J

G

A

T

V

A

L

V

M

J

G

A

L

R

E

S

T

R

A

I N

A

N

L

B

O

X

E

S

N

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#10

EXISTING WELL TO BE ABANDONED AFTER THE

NEW WATER SERVICE IS INSTALLED AND IN USE

INSTALL NEW 1-1/2"

WATER SERVICE

AND CURB STOP -

SEE DETAIL

DRAWING C-503.

CONTRACTOR TO

CONFIRM LOCATION

OF EXISTING SEPTIC

SYSTEM AND

CURTAIN DRAIN.

MC

MC

1" = 40'

1 3

T O

F

D

U R

H A

M

J O

H N

Y

S I T

E

P

L A

N

SER-DUR-10JOHNS.dwg

INSTALL WATER METER PIT - SEE

DETAIL DRAWING C-503

CONFIRM LOCATION OF

CURTAIN DRAIN.

1-1/2" TYPE K

COPPER WATER

SERVICE

M

CONTRACTOR TO REMOVE EXISTING

WATER TREATMENT SYSTEM

COMPONENTS AND PIPING

CONNECT TO EXISTING

COLD WATER FEED PIPE

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE

NEW WATER SERVICE

PIPING AND COMPONENTS.

SEE DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT

AT FOUNDATION INTERIOR

JT

JT

" = 1' - 0"

2 3

60275749

JANUARY 2018

T O

D

U R

H A

M

J O

H N

Y

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

I E

W

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND

HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO MAIN

ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW WATER

SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS IN

ACCORDANCE WITH THE SPECIFICATIONS.

10 John's Way.dwg

SECTION A-A

A

CONNECT TO EXISTING

COLD WATER FEED PIPE

NEW WATER SERVICE

PIPING AND

COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

CONTRACTOR TO REMOVE AND

DISPOSE OF EXISTING WATER

TREATMENT SYSTEM

COMPONENTS AND PIPING

CUT AND PLUG EXISTING WELL

PIPE WATER TIGHT AT FOUNDATION

INTERIOR

JT

JT

" = 1' - 0"

3 3

60275749

JANUARY 2018

T O

D

U R

H A

M

J O

H N

Y

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

W

WEST VIEW

10 John's Way.dwg

17 John’s Way

N

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WELL WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#17

EXISTING WELL TO BE

ABANDONED

PROPERTY IS

ALREADY

CONNECTED TO

WATER SERVICE

NV

NV

1" = 40'

1 1

T O

D

U R

H A

M

J O

H N

Y

S I T

E

P

L A

SER-DUR-17JOHNS.dwg

119 Main Street

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#119

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

MC

MC

1" = 40'

1 3

T O

D

U R

H A

M

M

A

S I T

E

P

L A

SER-DUR-119MAIN.dwg

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NEW WATER SERVICE PIPING

AND COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED.

CONNECT TO

EXISTING COLD

WATER FEED PIPE

A

CUT AND PLUG

EXISTING WELL PIPE

AND WELL PUMP

ELECTRICAL CONDUIT

WATER TIGHT AT

FOUNDATION

INTERIOR

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX, AND

HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE

DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES

BACK TO MAIN ELECTRICAL PANEL, AND DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO

NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL

CODE.REQUIREMENTS.

NV

NV

3/16" = 1' - 0"

2 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

119 Main Street.dwg

NEW WATER SERVICE PIPING

AND COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED.

CUT AND PLUG EXISTING WELL

PIPE AND WELL PUMP ELECTRICAL

CONDUIT WATER TIGHT AT

FOUNDATION INTERIOR

CORE AND SEAL

PENETRATION

FOR NEW

WATER SERVICE

PIPE

CONNECT TO EXISTING

COLD WATER FEED PIPE

NV

NV

3/16" = 1' - 0"

3 3

T O

D

U R

H A

M

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

119 Main Street.dwg

120 Main Street

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#120

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER SERVICE AND CURB STOP - SEE

DETAIL DRAWING C-503. NOTE: TOWN RECORDS INDICATE

THIS PROPERTY WAS ONCE CONNECTED TO DCWS.

CONTRACTOR MAY ENCOUNTER AN OLD WATER SERVICE

LATERAL.

MC

MC

1" = 40'

1 3

T O

D

U R

H A

M

M

A

S I T

E

P

L A

SER-DUR-120MAIN.dwg

CONNECT TO

EXISTING COLD

WATER FEED

PIPE

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE.

LOCATION ON EAST SIDE OF

HOUSE TO AVOID SEPTIC

TANKS

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT AT

FOUNDATION INTERIOR

UNDER STAIRS

A

CONTRACTOR TO REMOVE

EXISTING WATER

TREATMENT SYSTEM

COMPONENTS AND PIPING

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL

CONTROLLER BOX, AND HYDROPNEUMATIC TANK AND DISPOSE OF

ALL MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL

FEED WIRES BACK TO MAIN ELECTRICAL PANEL, AND DISCONNECT

WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN

ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN

CONFORMANCE WITH ALL ELECTRICAL CODE.REQUIREMENTS.

4. REMOVE AND DISPOSE OF ANY WATER TREATMENT SYSTEM

COMPONENTS IN ACCORDANCE WITH THE SPECIFICATIONS.

NV

NV

" = 1' - 0"

2 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

120 Main Street.dwg

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT AT

FOUNDATION INTERIOR

CONTRACTOR TO REMOVE EXISTING

WATER TREATMENT SYSTEM

COMPONENTS AND PIPING

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE ON

EAST SIDE OF

HOUSE TO AVOID

SEPTIC TANKS

NEW WATER SERVICE

PIPING AND

COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED

CONNECT TO

EXISTING

COLD WATER

FEED PIPE

NV

NV

" = 1' - 0"

3 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

120 Main Street.dwg

127 Main Street

JANUARY 2018

00 20' 40'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#127

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE.

NOTE WELL IS LOCATED IN

BASEMENT

NV

NV

1" = 20'

1 3

T O

D

U R

H A

M

M

A

S I T

E

P

L A

N

SER-DUR-127MAIN.dwg

CONTRACTOR TO VERIFY

LOCATION OF EXISTING

WATER SERVICE AND

CURB STOP - SEE DETAIL

DRAWING C-503

CONNECT TO EXISTING COLD

WATER FEED PIPE

NEW WATER SERVICE PIPING

AND COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED.

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

CONTRACTOR TO REMOVE EXISTING

WATER SYSTEM COMPONENTS AND

PIPING.

CUT AND PLUG EXISTING WELL

WATER TIGHT AT FOUNDATION

INTERIOR

A

N

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX, AND

HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE

DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK

TO MAIN ELECTRICAL PANEL, AND DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO

NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL

CODE.REQUIREMENTS.

NV

NV

3/16" = 1' - 0"

2 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

127 Main Street.dwg

CUT AND PLUG EXISTING WELL

WATER TIGHT AT FOUNDATION

INTERIOR

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NEW WATER SERVICE PIPING

AND COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED.

CONNECT TO EXISTING

COLD WATER FEED PIPE

REMOVE AND DISPOSE

OF ALL WATER SYSTEM

COMPONENTS

NV

NV

1/4" = 1' - 0"

3 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

127 Main Street.dwg

151R and 153 Main Street

R

E

R

T

E

209+25

M

M

I

P

N

E

M

A

R

E

T

E

N

60275749

APRIL 2018

00 20' 40'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#153

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW 1-1/2"

WATER SERVICES

AND CURB STOPS -

SEE DETAIL DRAWING

C-503

NV

NV

1" = 20'

1 5

T O

D

U R

H A

M

M

A

S I T

E

P

L A

N

SER-DUR-153 & 151RMAIN.dwg

#151R

INSTALL WATER

METER - SEE DETAIL

DRAWING C-503

1-1/2" TYPE K

SERVICES

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT AT

FOUNDATION INTERIOR

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CONNECT TO EXISTING

COLD WATER FEED PIPE

CONTRACTOR TO

REMOVE EXISTING

PIPING

A

NV

NV

" = 1' - 0"

2 5

151 Main Street (153 in pictures).dwg

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL

CONTROLLER BOX, AND HYDROPNEUMATIC TANK AND DISPOSE OF

ALL MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL

FEED WIRES BACK TO MAIN ELECTRICAL PANEL, AND DISCONNECT

WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN

ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN

CONFORMANCE WITH ALL ELECTRICAL CODE.REQUIREMENTS.

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT AT

FOUNDATION INTERIOR

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CONNECT TO EXISTING

COLD WATER FEED PIPE

CONTRACTOR TO

REMOVE EXISTING

PIPING

NV

NV

" = 1' - 0"

3 5

PENETRATION FOR

NEW WATER

SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CONTRACTOR TO REMOVE EXISTING

WATER TREATMENT SYSTEM

COMPONENTS AND PIPING

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT AT

FOUNDATION INTERIOR

A

CONNECT TO EXISTING COLD

WATER FEED PIPE

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL

CONTROLLER BOX, AND HYDROPNEUMATIC TANK AND DISPOSE OF

ALL MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL

FEED WIRES BACK TO MAIN ELECTRICAL PANEL, AND DISCONNECT

WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN

ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN

CONFORMANCE WITH ALL ELECTRICAL CODE.REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM

COMPONENTS IN ACCORDANCE WITH THE SPECIFICATIONS.

NV

NV

" = 1' - 0"

4 5

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

153 Main Street (151 in pictures).dwg

CONNECT TO EXISTING

COLD WATER FEED PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CONTRACTOR TO REMOVE

AND DISPOSE OF EXISTING

WATER TREATMENT SYSTEM

COMPONENTS AND PIPING

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT AT

FOUNDATION INTERIOR

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE

NV

NV

" = 1' - 0"

5 5

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

167 Main Street

N

60275749

JANUARY 2018

00 20' 40'

NOTES:

1. CONTRACTOR MAY ENCOUNTER OLD DURHAM WATER SERVICE ON THE PROPERTY.

2. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

3. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

4. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

5. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#167

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

JT

JT

1" = 20'

1 3

T O

D

U R

H A

M

M

A

S I T

E

P

L A

SER-DUR-167MAIN.dwg

CONTRACTOR TO REMOVE

EXISTING WATER

TREATMENT SYSTEM

COMPONENTS AND PIPING

CONNECT TO EXISTING

COLD WATER FEED PIPE

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1, SHEET

C-503. PROVIDE FITTINGS AND PIPING

SUPPORTS AS NEEDED

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT

AT FOUNDATION INTERIOR

JT

JT

" = 1' - 0"

2 3

60275749

APRIL 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

N

167 Main St.dwg

NOTES:

1. DISCONNECT EXISTING WELL PUMP, WELL CONTROLLER BOX AND

HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS

OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL

FEED WIRES BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT

WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN

ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN

CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM

COMPONENTS IN ACCORDANCE WITH THE SPECIFICATIONS..

CONNECT TO EXISTING

COLD WATER FEED PIPE

NEW WATER SERVICE PIPING

AND COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND PIPING

SUPPORTS AS NEEDED

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

CONTRACTOR TO REMOVE EXISTING

WATER TREATMENT SYSTEM

COMPONENTS AND PIPING

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT

AT FOUNDATION INTERIOR

SECTION A-A

A

JT

JT

1/4" = 1' - 0"

3 3

60275749

APRIL 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

W

167 Main St.dwg

NORTH VIEW

168 Main Street

N

60275749

JANUARY 2018

00 20' 40'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#168EXISTING WELL (ACCESS IN

BASEMENT) TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

JT

JT

1" = 20'

1 4

T O

D

U R

H A

M

M

A

S I T

E

P

L A

N

SER-DUR-168MAIN.dwg

RESTORE

DRIVEWAY

PAVEMENT

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS NEEDED

CUT AND PLUG

EXISTING WELL PIPE

WATER TIGHT AT

FOUNDATION

INTERIOR

CONTRACTOR TO REMOVE

EXISTING WATER

TREATMENT SYSTEM

COMPONENTS AND PIPING

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

A

B

JT

JT

" = 1' - 0"

2 4

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

168 Main St.dwg

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP,

WELL CONTROLLER BOX AND HYDROPNEUMATIC

TANK AND DISPOSE OF ALL MATERIALS UNLESS

OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX,

REMOVE ELECTRICAL FEED WIRES BACK TO MAIN

ELECTRICAL PANEL AND DISCONNECT WIRES FROM

PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM

EXISTING MAIN ELECTRICAL PANEL TO NEW WATER

SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH

ALL ELECTRICAL CODE REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER

TREATMENT SYSTEM COMPONENTS IN

CONNECT TO EXISTING

COLD WATER FEED PIPE

CUT AND PLUG EXISTING WELL

PIPE WATER TIGHT AT

FOUNDATION INTERIOR

CONTRACTOR TO REMOVE EXISTING

WATER TREATMENT SYSTEM COMPONENTS

AND PIPING

JT

JT

" = 1' - 0"

3 4

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

E

W

168 Main St.dwg

SECTION B-B

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1, SHEET

C-503. PROVIDE FITTINGS AND PIPING

SUPPORTS AS NEEDED

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

JT

JT

" = 1' - 0"

4 4

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

E

W

168 Main St.dwg

175R Main Street

P

I C

K

E

N

E

N

60275749

APRIL 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION

OF EXISTING SEPTIC SYSTEM AND

AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL

CONDITION.

3. EXISTING WATER SERVICE PIPE AND

WELL PUMP POWER DUCT TO BE CUT

AND CAPPED WATERTIGHT AT WELL

AND BUILDING INTERIOR AND

ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING

SUBMERSIBLE WELL PUMP FROM

WELL UNLESS OTHERWISE DIRECTED.

#175R

EXISTING WELL

TO BE

ABANDONED

AFTER THE NEW

WATER SERVICE

IS INSTALLED

AND IN USE

INSTALL NEW 1-1/2"

WATER SERVICE AND

CURB STOP - SEE

DETAIL DRAWING

C-503

NV

NV

1" = 40'

1 3

T O

D

U R

H A

M

R

E E

T

S I T

E

P

L A

N

SER-DUR-175RMAIN.dwg

INSTALL WATER

METER PIT - SEE

DETAIL DRAWING

C-503

1-1/2" TYPE K

CORE AND SEAL PENETRATION

FOR NEW WATER SERVICE PIPE

CUT AND PLUG EXISTING WELL

PIPE AND WELL PUMP ELECTRICAL

CONDUIT WATER TIGHT AT

FOUNDATION INTERIOR

NEW WATER SERVICE PIPING

AND COMPONENTS. SEE DETAIL

1, SHEET C-503. PROVIDE

FITTINGS AND PIPING SUPPORTS

AS NEEDED.

A

1/4" = 1' - 0"

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER

BOX, AND HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS

UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED

WIRES BACK TO MAIN ELECTRICAL PANEL, AND DISCONNECT WIRES

FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL

PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE

WITH ALL ELECTRICAL CODE.REQUIREMENTS.

N

T O

D

U R

H A

M

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

CONNECT TO EXISTING

COLD WATER FEED PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS NEEDED.

CUT AND PLUG EXISTING WELL PIPE

AND WELL PUMP ELECTRICAL

CONDUIT WATER TIGHT AT

FOUNDATION INTERIOR

1/4" = 1' - 0"

T O

D

U R

H A

M

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

176 Main Street

M

N

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#176

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

JT

JT

1" = 40'

1 3

T O

D

U R

H A

M

M

A

S I T

E

P

L A

N

SER-DUR-176MAIN.dwg

EXISTING INACTIVE WELL

TO BE ABANDONED

RESTORE

CONTRACTOR TO REMOVE EXISTING

WATER TREATMENT SYSTEM

COMPONENTS AND PIPING

CONNECT TO

EXISTING COLD

WATER FEED

PIPE

CORE AND

SEAL

PENETRATION

FOR NEW

WATER

SERVICE PIPE

NEW WATER SERVICE PIPING AND COMPONENTS. SEE

DETAIL 1, SHEET C-503. PROVIDE FITTINGS AND PIPING

SUPPORTS AS NEEDED

CUT AND PLUG EXISTING WELL PIPE WATER

TIGHT AT FOUNDATION INTERIOR

JT

JT

" = 1' - 0"

2 3

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND HYDROPNEUMATIC TANK AND

DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL

PANEL AND DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE

AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS IN ACCORDANCE WITH THE

SPECIFICATIONS.

176 Main St.dwg

CONTRACTOR TO

REMOVE EXISTING

WATER TREATMENT

SYSTEM

COMPONENTS AND

PIPING

CONNECT TO EXISTING

COLD WATER FEED PIPE

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS NEEDED

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT AT

FOUNDATION INTERIOR

JT

JT

" = 1' - 0"

3 3

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

W

176 Main St.dwg

177R Main Street

N

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#177R

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

JT

JT

1" = 40'

1 3

T O

D

U R

H A

M

S I T

E

P

L A

SER-DUR-177RMAIN.dwg

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NEW WATER SERVICE

PIPING AND COMPONENTS.

SEE DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED

CUT AND PLUG

EXISTING WELL PIPE

WATER TIGHT AT

FOUNDATION INTERIOR

A

JT

JT

" = 1' - 0"

2 3

60275749

JANUARY 2018

T O

D

U R

H A

M

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND

HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO

MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW

WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE

REQUIREMENTS.

177R Main St.dwg

CONNECT TO EXISTING

COLD WATER FEED PIPE

CONTRACTOR TO REMOVE

EXISTING WATER SYSTEM

COMPONENTS AND PIPING.

CUT AND PLUG EXISTING

WELL PIPE AND WELL PUMP

ELECTRICAL CONDUIT

WATER TIGHT AT

FOUNDATION INTERIOR

NV

NV

" = 1' - 0"

3 3

60275749

JANUARY 2018

T O

D

U R

H A

M

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

177R Main St.dwg

186 Main Street

N

60275749

JANUARY 2018

00 20' 40'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#186

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

JT

JT

1" = 20'

1 3

T O

D

U R

H A

M

M

A

S I T

E

P

L A

N

SER-DUR-186MAIN.dwg

RESTORE

CONTRACTOR TO REMOVE

EXISTING WATER TREATMENT

SYSTEM COMPONENTS AND

PIPING

CONNECT TO EXISTING

COLD WATER FEED PIPE

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1, SHEET

C-503. PROVIDE FITTINGS AND PIPING

SUPPORTS AS NEEDED

CUT AND PLUG

EXISTING WELL PIPE

WATER TIGHT AT

FOUNDATION

INTERIOR

A

JT

JT

" = 1' - 0"

2 3

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

186 Main St.dwg

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND HYDROPNEUMATIC TANK AND

DISPOSE OF ALL MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL

PANEL AND DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE

AND INSTALL IN CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS IN ACCORDANCE WITH THE

CONNECT TO EXISTING COLD

WATER FEED PIPE

CORE AND SEAL PENETRATION

FOR NEW WATER SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS NEEDED

CUT AND PLUG EXISTING

WELL PIPE WATER TIGHT

AT FOUNDATION INTERIOR

JT

JT

" = 1' - 0"

3 3

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

W

186 Main St.dwg

188 Main Street

M

M

A

R

E

T

N

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#188

EXISTING WELL TO BE

ABANDONED AFTER THE

NEW WATER SERVICE IS

INSTALLED AND IN USE

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

JT

JT

1" = 40'

1 4

T O

D

U R

H A

M

M

A

S I T

E

P

L A

N

SER-DUR-188MAIN.dwg

RESTORE

DRIVEWAY

PAVEMENT

INSTALL NEW WATER SERVICE 10' FROM

THE PROPERTY LINE TO ALLOW FOR

USE OF FRONT YARD FOR FUTURE

REPLACEMENT OF SEPTIC SYSTEM

10'

CONTRACTOR TO

REMOVE EXISTING

WATER TREATMENT

SYSTEM

COMPONENTS AND

PIPING

CONNECT TO

EXISTING COLD

WATER FEED PIPE

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE

NEW WATER

SERVICE PIPING

AND COMPONENTS.

SEE DETAIL 1,

SHEET C-503.

PROVIDE FITTINGS

AND PIPING

SUPPORTS AS

NEEDED

CUT AND PLUG

EXISTING WELL PIPE

WATER TIGHT AT

FOUNDATION INTERIOR

B

JT

JT

" = 1' - 0"

2 4

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

188 Main St.dwg

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND HYDROPNEUMATIC TANK AND DISPOSE OF ALL

MATERIALS UNLESS OTHERWISE DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL PANEL AND

DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL TO NEW WATER SERVICE. SIZE AND INSTALL IN

CONFORMANCE WITH ALL ELECTRICAL CODE REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS IN ACCORDANCE WITH THE SPECIFICATIONS.

CONTRACTOR TO REMOVE EXISTING

WATER TREATMENT SYSTEM

COMPONENTS AND PIPING

CUT AND PLUG EXISTING WELL PIPE WATER

TIGHT AT FOUNDATION INTERIOR

SECTION A-A

A

JT

JT

1/4" = 1' - 0"

3 4

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

W

188 Main St.dwg

SOUTH VIEW

SECTION B-B

NEW WATER SERVICE

PIPING AND COMPONENTS.

SEE DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND

PIPING SUPPORTS AS

NEEDED

CONNECT TO EXISTING

COLD WATER FEED PIPE

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

JT

JT

1/4" = 1' - 0"

4 4

60275749

JANUARY 2018

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

W

188 Main St.dwg

EAST VIEW

196 Main Street

M

N

60275749

APRIL 2018

00 20' 40'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OFEXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#196

EXISTING WELL TO BE

ABANDONED AFTER THE NEW

WATER SERVICE IS INSTALLED

AND IN USE

INSTALL NEW 2"

WATER SERVICE AND

CURB STOP - SEE

DETAIL DRAWING

C-503.

NV

NV

1" = 40'

1 3

T O

D

U R

H A

M

M

A

R

E E

T

S I T

E

P

L A

N

SER-DUR-196MAIN.dwg

INSTALL WATER

METER PIT - SEE

DETAIL DRAWING

C-503.

2" TYPE K

COPPER

WATER

CONTRACTOR TO REMOVE

EXISTING WATER TREATMENT

SYSTEM COMPONENTS AND

PIPING

CONNECT TO EXISTING COLD

WATER FEED PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CUT AND PLUG EXISTING WELL PIPE

AND WELL PUMP ELECTRICAL

CONDUIT AT INTERIOR

INSTALL NEW WATER SERVICE IN

EXISTING CONDUIT USED FOR

WELL PIPE AND SEAL OPENING AT

FOUNDATION INTERIOR

NV

NV

1/4" = 1' - 0"

2 3

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

196 Main Street.dwg

60275749

JANUARY 2018

NOTES:

1. DISCONNECT EXISTING SUBMERSIBLE WELL PUMP, WELL CONTROLLER BOX AND

HYDROPNEUMATIC TANK AND DISPOSE OF ALL MATERIALS UNLESS OTHERWISE

DIRECTED.

2. DISCONNECT EXISTING PUMP CONTROL BOX, REMOVE ELECTRICAL FEED WIRES

BACK TO MAIN ELECTRICAL PANEL AND DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL

TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL

ELECTRICAL CODE REQUIREMENTS.

4. REMOVE AND DISPOSE OF EXISTING WATER TREATMENT SYSTEM COMPONENTS IN

CONNECT TO EXISTING

COLD WATER FEED PIPE

NEW WATER SERVICE PIPING

AND COMPONENTS. SEE

DETAIL 1, SHEET C-503.

PROVIDE FITTINGS AND PIPING

SUPPORTS AS NEEDED.

CUT EXISTING WELL PIPE AND

WELL PUMP ELECTRICAL CONDUIT

A

INSTALL NEW WATER SERVICE IN

EXISTING CONDUIT USED FOR

WELL PIPE AND SEAL OPENING AT

FOUNDATION INTERIOR

NV

NV

1/4" = 1' - 0"

3 3

T O

D

U R

H A

M

M

A

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

E L

E V

A T

I O

N

V

I E

W

JANUARY 2018

199 Main Street

M

A

R

E

T

N

60275749

JANUARY 2018

00 20' 40'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS OTHERWISE

DIRECTED.

#199

DISCONNECT EXISTING

WATER SERVICE FROM #203R

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

NV

NV

1" = 40'

1 3

T O

D

U R

H A

M

M

A

R

E E

T

S I T

E

P

L A

SER-DUR-199MAIN.dwg

WATER FEED

PIPE

CORE AND SEAL

PENETRATION FOR

NEW WATER

SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CUT AND PLUG EXISTING

PIPE WATER TIGHT AT

FOUNDATION INTERIOR

A

CONTRACTOR TO REMOVE

EXISTING WATER METER AND

PIPING

NV

NV

3/16" = 1' - 0"

2 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

199 Main Street.dwg

N

NOTES:

1. REMOVE EXISTING SERVICE FROM 203R MAIN STREET.

2. REMOVE ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL PANEL, AND

DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL

TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL

ELECTRICAL CODE.REQUIREMENTS.

CONNECT TO EXISTING

COLD WATER FEED PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1, SHEET

C-503. PROVIDE FITTINGS AND PIPING

SUPPORTS AS NEEDED.

CUT AND PLUG EXISTING PIPE

WATER TIGHT AT FOUNDATION

INTERIOR

CONTRACTOR TO REMOVE

EXISTING WATER METER AND

PIPING

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NV

NV

3/16" = 1' - 0"

3 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

199 Main Street.dwg

201 Main Street

N

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE FROM 203R MAIN STREET TO BE CUT AND CAPPED WATERTIGHT

AT BUILDING INTERIOR AND ABANDONED IN PLACE.

#201

DISCONNECT EXISTING

WATER SERVICE FROM #203R

INSTALL NEW WATER

SERVICE AND CURB

STOP - SEE DETAIL

DRAWING C-503

NV

NV

1" = 40'

1 3

T O

D

U R

H A

M

M

A

R

E E

T

S I T

E

P

L A

N

SER-DUR-201MAIN.dwg

LOCATE AND AVOID

WASTEWATER PIPE

FROM BUILDING

WATER FEED

PIPE

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NEW WATER SERVICE PIPING AND

COMPONENTS. SEE DETAIL 1,

SHEET C-503. PROVIDE FITTINGS

AND PIPING SUPPORTS AS

NEEDED

CUT AND PLUG EXISTING PIPE

WATER TIGHT AT FOUNDATION

INTERIOR

A

CONTRACTOR TO

REMOVE EXISTING VALVE

AND PIPING

NV

NV

" = 1' - 0"

2 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

W

201 Main Street.dwg

NOTES:

1. REMOVE EXISTING SERVICE FROM 203R MAIN STREET.

2. REMOVE ELECTRICAL FEED WIRES BACK TO MAIN ELECTRICAL PANEL, AND

DISCONNECT WIRES FROM PANEL.

3. INSTALL NEW COPPER BONDING WIRE FROM EXISTING MAIN ELECTRICAL PANEL

TO NEW WATER SERVICE. SIZE AND INSTALL IN CONFORMANCE WITH ALL

ELECTRICAL CODE.REQUIREMENTS.

CONNECT TO EXISTING

COLD WATER FEED PIPE

NEW WATER

SERVICE PIPING

AND COMPONENTS.

SEE DETAIL 1,

SHEET C-503.

PROVIDE FITTINGS

AND PIPING

SUPPORTS AS

NEEDED.

CUT AND PLUG EXISTING PIPE

WATER TIGHT AT FOUNDATION

INTERIOR

CONTRACTOR TO REMOVE

EXISTING VALVE AND PIPING

CORE AND SEAL

PENETRATION FOR NEW

WATER SERVICE PIPE

NV

NV

" = 1' - 0"

3 3

T O

D

U R

H A

M

M

A

R

E E

T

I N

T E

R I O

R

S

E R

V I C

E

C

O N

N E

C T

I O

N S

P L

E

201 Main Street.dwg

202 Main Street

N

60275749

JANUARY 2018

00 40' 80'

NOTES:

1. CONTRACTOR TO CONFIRM LOCATION OF EXISTING SEPTIC SYSTEM AND AVOID AREA.

2. RESTORE LANDSCAPING TO ORIGINAL CONDITION.

3. EXISTING WATER SERVICE PIPE AND WELL PUMP POWER DUCT TO BE CUT AND CAPPED

WATERTIGHT AT WELL AND BUILDING INTERIOR AND ABANDONED IN PLACE.

4. REMOVE AND DISPOSE OF EXISTING SUBMERSIBLE WELL PUMP FROM WELL UNLESS…