AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

This amendment is to provide responses to RFI's, extend the proposal response date and provide revisions to the project specif ications.

1. CONTRACT ID CODE PAGE OF PAGES

1 30

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 06-Apr-2016

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912WJ-16-R-0007

X 9B. DATED (SEE ITEM 11)

05-Feb-2016

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

06-Apr-2016

CODE

US ARMY ENGR DISTRICT, NEW ENGLAND

696 VIRGINIA ROAD

CONCORD MA 01742-2751

W912WJ 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912WJ-16-R-0007

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION 00010 - SOLICITATION CONTRACT FORM

The required response date/time has changed from 22-Apr-2016 04:30 PM to 29-Apr-2016 04:30 PM.

The contractor period of performance end date has increased by 100 days from 800 days to 900 days.

SECTION 00100 - BIDDING SCHEDULE/INSTRUCTIONS TO BIDDERS

The following have been added by full text:

AMENDMENT 4

RFI’s

1. Can a project at least 90% complete be considered as past performance?

Response: No

Revised Sections and Paragraphs of the Solicitation are as follows:

2. Section 00 80 00 1.1 (C) indicates 900 calendar days and the SF1442 indicates 800. Please confirm which is accurate.

Response: The number of calendar days is 900.

3. Based on the Commissioning specification, it appears the Commissioning Agent and all Commissioning requirements (systems & envelope) will be under the GC Contract. We’ve built many schools in Massachusetts under the guidelines of MSBA, so I just want to make sure that I’m interpreting the correctly. Generally, we see the Commissioning Agent under a separate contract with the Awarding Authority. Please confirm this is not the case on the Hanscom AFB project.

Response: Yes, as stated in Section 01 91 13, the Contractor shall provide the Commissioning Firm and the Commissioning Agent.

4. After review of the drawings, the graphical scale seems to be off from what is being called out as the scale. If the scale says 1/8" = 1'-0", then the drawing is scaled correctly; however, the graphical scale is incorrect.

Response: All drawings scale correctly based on the stated scale. There is an error on some sheets concerning the largest dimension on the graphic scale (other dimensions on the graphic scales are correct).

5. We understand that the Unified Facilities Criteria (UFC), including UFC 3-520-01 and the Unified Facilities Guide Specifications (UFGS) shall apply for purposes of bidding and project execution. Can you confirm that our understanding is accurate?

Response: Unified Facilities Criteria (UFC) including UFC 3-520-01 provide design criteria. The UFCs apply to this construction contract only to the extent referenced in the solicitation documents. The Unified Facilities Guide Specifications (UFGS) were used to create the Specifications included in the solicitation documents. The offerors shall bid on the Specifications included in the solicitation documents

Calendar Days

All references to the number of calendar days in sections L & M have been changed from 800 to 900 days.

SECTION TABLE OF CONTENTS

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

AMENDMENT 0004 OF SOLICITATION

1.1 CHANGES TO SPECIFICATIONS

1.1.1 Narrative Changes to the Specifications

-- End of Section Table of Contents --

AMENDMENT 0004 OF SOLICITATION

1.1 CHANGES TO SPECIFICATIONS

1.1.1 Narrative Changes to the Specifications

1. Section 01 00 00 GENERAL REQUIREMENTS, Subpart 1.9; replace subparagraph d with the following:

d. The superintendent shall not serve as either the Contractor Quality Control (CQC) System Manager or the Site Safety and Health Officer (SSHO).

2. Section 07 84 00 FIRESTOPPING, Subpart 1.4.2; replace Subpart 1.4.2 with the following:

1.4.2 Inspector Qualifications

The inspector shall meet the criteria contained in ASTM E699 for agencies involved in quality assurance and shall have a minimum of two years experience in construction field inspections of firestopping systems, products, and assemblies. The inspector shall be completely independent of, and divested from, the installer, the manufacturer, and the supplier of any material or item being inspected. The inspector shall not be a competitor of the installer, the contractor, the manufacturer, or supplier of any material or item being inspected. Include in the qualifications submittal a notarized statement assuring compliance with the requirements stated herein.

3. Section 07 84 00 FIRESTOPPING, Subpart 3.3.1; replace the first two sentences in Subpart

3.3.1 with the following:

For all projects, the firestopped areas shall not be covered or enclosed until inspection is complete and approved by the Contracting Officer. The inspector must inspect the applications initially to ensure adequate preparations (clean surfaces suitable for application, etc.) and periodically during the work to assure that the completed work has been accomplished according to the manufacturer's written instructions and the specified requirements.

3. Section 08 71 00 DOOR HARDWARE; add attached Hardware Sets to the end of this section.

Hardware Sets

Hanscom Primary School, Hanscom AFB, Massachusetts

Section 08 71 00 Page 29

Hardware Set No. 01

For use on door #(s):

1A00.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD EPT 628 IVE

2 EA POWER TRANSFER EPT10 689 VON

1 EA KEYED REMOVABLE

MULLION

KR4954-STAB 689 VON

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-EO 626 FAL

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-NL-OP 626 FAL

1 EA INTERFACE BOX JB7 GRAY VON

1 EA RELAY RELAY KIT-R6 VON

1 EA RIM HOUSING C953 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

2 EA OH STOP 100S 630 GLY

1 EA SURFACE CLOSER SC71 HDPA 689 FAL

1 EA SURF. AUTO

OPERATOR

9542 MS ANCLR LCN

1 EA WEATHER RING 8310-801 PLA LCN

1 EA ACTUATOR, WALL

MOUNT

8310-853T 630 LCN

1 EA ACTUATOR, WALL

MOUNT

8310-855 630 LCN

1 EA FLUSH MOUNT BOX 8310-867F 689 LCN

1 EA THRESHOLD 896S AL NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS914 900-2RS LGR VON

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by remote release via access control system or key override which will unlock electrified door.

3. Free egress from inside at all times.

4. Door position switch and request to exit connected to access control system for monitoring.

5. When door is in unlocked position, ADA operator by either ADA wall plate actuator.

Hardware Set No. 02

For use on door #(s):

1A00.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD EPT 628 IVE

1 EA POWER TRANSFER EPT10 689 VON

Section 08 71 00 Page 30

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-EO 626 FAL

1 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

1 EA OH STOP 100S 630 GLY

1 EA SURFACE CLOSER SC71 HDPA 689 FAL

1 EA THRESHOLD 896S AL NGP

1 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS914 900-2RS LGR VON

1 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by valid card credential, remote release via access control system or key override which will unlock electrified door.

3. Free egress from inside at all times.

4. Door position switch and request to exit connected to access control system for monitoring.

Hardware Set No. 03

For use on door #(s):

1C00.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD EPT 628 IVE

2 EA POWER TRANSFER EPT10 689 VON

1 EA KEYED REMOVABLE

MULLION

KR4954-STAB 689 VON

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-EO 626 FAL

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-NL-OP 626 FAL

1 EA INTERFACE BOX JB7 GRAY VON

1 EA RELAY RELAY KIT-R6 VON

1 EA RIM HOUSING C953 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

2 EA OH STOP 100S 630 GLY

1 EA SURFACE CLOSER SC71 HDPA 689 FAL

1 EA SURF. AUTO

OPERATOR

9542 MS ANCLR LCN

1 EA ACTUATOR, WALL

MOUNT

8310-853T 630 LCN

1 EA FLUSH MOUNT BOX 8310-867F 689 LCN

1 EA DESK MOUNT BUTTON 660-PB 628 SCE

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS914 900-2RS LGR VON

1 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by valid card credential, remote release via access control system or key override which will unlock electrified door.

3. Free egress from inside at all times.

Section 08 71 00 Page 31

4. Door position switch and request to exit connected to access control system for monitoring.

5. When door is in unlocked position, ADA operator by either ADA wall plate actuator.

Hardware Set No. 04

For use on door #(s):

1C00.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD EPT 628 IVE

1 EA POWER TRANSFER EPT10 689 VON

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-EO 626 FAL

1 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

1 EA OH STOP 100S 630 GLY

1 EA SURFACE CLOSER SC71 HDPA 689 FAL

1 EA THRESHOLD 896S AL NGP

1 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS914 900-2RS LGR VON

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by remote release via access control system or key override which will unlock electrified door.

3. Free egress from inside at all times.

4. Door position switch and request to exit connected to access control system for monitoring.

Hardware Set No. 05

For use on door #(s):

1F06.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

1 EA KEYED REMOVABLE

MULLION

KR4954-STAB 689 VON

1 EA PANIC HARDWARE 25-R-EO 626 FAL

1 EA PANIC HARDWARE 25-R-L-NL-QUA 626 FAL

1 EA RIM HOUSING C953 626 FAL

1 EA MORTISE CYLINDER C987 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA OH STOP 100S 630 GLY

2 EA SURFACE CLOSER SC71 HDPA 689 FAL

2 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA THRESHOLD 896S AL NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

DOOR OPERATION:

1. Door position switch to be connected to access control system for monitoring.

Section 08 71 00 Page 32

Hardware Set No. 06

For use on door #(s):

1F04.1 1F05.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

1 EA KEYED REMOVABLE

MULLION

KR4954-STAB 689 VON

1 EA PANIC HARDWARE 25-R-EO 626 FAL

1 EA PANIC HARDWARE 25-R-L-NL-QUA 626 FAL

1 EA RIM HOUSING C953 626 FAL

1 EA MORTISE CYLINDER C987 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA SURFACE CLOSER SC71 SS 689 FAL

1 SET SEALS 5050B BRN NGP

1 SET ASTRAGAL 140PA CL NGP

1 EA THRESHOLD 896S AL NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

Hardware Set No. 07

For use on door #(s):

1C05.2 1C05.3 1D00.2

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD EPT 628 IVE

2 EA POWER TRANSFER EPT10 689 VON

1 EA KEYED REMOVABLE

MULLION

KR4954-STAB 689 VON

1 EA ELEC PANIC

HARDWARE

RX-EL-25-R-EO 626 FAL

1 EA ELEC PANIC

HARDWARE

RX-EL-25-R-NL-OP 626 FAL

1 EA RIM HOUSING C953 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

2 EA OH STOP 100S 630 GLY

2 EA SURFACE CLOSER SC71 HDPA 689 FAL

1 SET SEALS 5050B BRN NGP

1 SET ASTRAGAL 140PA CL NGP

1 EA THRESHOLD 896S AL NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS914 900-2RS LGR VON

1 CARD READER BY OTHERS

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by valid credential or key override which will unlock electrified door.

Section 08 71 00 Page 33

3. Free egress from inside at all times.

4. Door position switch and request to exit connected to access control system for monitoring.

Hardware Set No. 08

For use on door #(s):

1C11.1 1D01.1 S2.1 S3.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD EPT 628 IVE

2 EA POWER TRANSFER EPT10 689 VON

1 EA KEYED REMOVABLE

MULLION

KR4954-STAB 689 VON

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-EO 626 FAL

1 EA ELEC PANIC

HARDWARE

RX-EL-24-R-NL-OP 626 FAL

1 EA RIM HOUSING C953 626 FAL

1 EA MORTISE CYLINDER C987 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

2 EA OH STOP 100S 630 GLY

2 EA SURFACE CLOSER SC71 HDPA 689 FAL

1 EA THRESHOLD 896S AL NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS914 900-2RS LGR VON

1 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by valid credential or key override which will unlock electrified door.

3. Free egress from inside at all times.

4. Door position switch and request to exit connected to access control system for monitoring.

Hardware Set No. 09

For use on door #(s):

1C00.3

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

1 EA 2 POINT LOCK MS1850-4085 628 ADA

2 EA MORTISE CYLINDER C987 626 FAL

2 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 SET PUSH/PULL BAR 9190-10"-NO 630 IVE

2 EA SURFACE CLOSER SC71 SS 689 FAL

2 EA DOOR SWEEP C627A CL NGP

1 EA THRESHOLD 896S AL NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

Section 08 71 00 Page 34

DOOR OPERATION:

1. Door position switch to be connected to access control system for monitoring.

Hardware Set No. 10

For use on door #(s):

1C01.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD 628 IVE

1 EA DEADBOLT MS1850 628 ADA

2 EA MORTISE CYLINDER C987 626 FAL

2 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

1 SET PUSH/PULL BAR 9190-10"-NO 630 IVE

1 EA SURFACE CLOSER SC71 SS 689 FAL

1 EA DOOR SWEEP C627A CL NGP

1 EA THRESHOLD 896S AL NGP

1 EA DOOR CONTACT 679-05HM BLK SCE

DOOR OPERATION:

1. Door position switch to be connected to access control system for monitoring.

Hardware Set No. 11

For use on door #(s):

1C11.2 1D01.2

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

2 SET PUSH/PULL BAR 9190-10"-NO 630 IVE

2 EA SURFACE CLOSER SC71 DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

2 EA SILENCER SR64 GRY IVE

Hardware Set No. 12

For use on door #(s):

1A01.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD EPT 628 IVE

1 EA POWER TRANSFER EPT10 689 VON

1 EA EU STOREOOM LOCK MA881HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

Section 08 71 00 Page 35

1 EA SURFACE CLOSER SC71 DS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

3 EA SILENCER SR64 GRY IVE

1 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS902 LGR SCE

1 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by valid credential or key override which will unlock electrified door.

3. Free egress from inside at all times.

4. Door position switch and request to exit connected to access control system for monitoring.

Hardware Set No. 13

For use on door #(s):

1A01.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 14

For use on door #(s):

1A01.3

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Section 08 71 00 Page 36

Hardware Set No. 15

For use on door #(s):

1A02.1 1A04.1 1A04.2 1A05.1 1A06.1 1A07.1 1A08.1 1A09.1 1A10.1 1A11.1 1C07.1 1C21.1 1C22.1 1C23.1 1C24.1 1D02.1 1D04.1 1D06.1 1D06.2 1D08.1 1D12.1 1D12.2 1E02.1 1E04.1 1E04.2 1E08.1 1E08.2 1E10.1 2G05.1 2G07.1 2G11.1 2H07.1 2H08.1 2I02.1 2I06.1 2I11.1 2J10.1 2J12.1 2J13.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA WALL STOP WS406CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 16

For use on door #(s):

1C02.1 1C02.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

Hardware Set No. 17

For use on door #(s):

1F02.1 1F03.1 1F03.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD 628 IVE

1 EA FIRE EXIT HARDWARE F-25-R-L-QUA 626 FAL

1 EA RIM HOUSING C953 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 HDPA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 5075B BRN NGP

Section 08 71 00 Page 37

Hardware Set No. 18

For use on door #(s):

1F01.1 1F04.3 1F06.3 2G06.1 2I10.1 2J14.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA STOREROOM LOCK MA581HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 5075B BRN NGP

Hardware Set No. 19

For use on door #(s):

1F06.2 1F06.4

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD 628 IVE

1 EA FIRE EXIT HARDWARE F-25-R-L-BE-QUA 626 FAL

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 5075B BRN NGP

Hardware Set No. 20

For use on door #(s):

1A12.1 1C08.4 1E06.2 2I12.1 2I13.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA STOREROOM LOCK MA581HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

Section 08 71 00 Page 38

Hardware Set No. 21

For use on door #(s):

1F00.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

6 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 SET AUTO FLUSH BOLT FB41P 630 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA STOREROOM LOCK MA581HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA COORDINATOR COR7G 626 IVE

2 EA SURFACE CLOSER SC71 DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA ASTRAGAL 5070 BRN NGP

Hardware Set No. 22

For use on door #(s):

1C05.4 1C15.1 1C17.1 1C18.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA STOREROOM LOCK MA581HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 23

For use on door #(s):

1C06.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

8 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 SET AUTO FLUSH BOLT FB41P 630 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA STOREROOM LOCK MA581HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA COORDINATOR COR X FL 628 IVE

2 EA MOUNTING BRACKET MB 689 IVE

2 EA SURFACE CLOSER SC71 DSHO 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 EA ASTRAGAL 5070 BRN NGP

Section 08 71 00 Page 39

Hardware Set No. 24

For use on door #(s):

1C06.2 1C07.2 1C19.1 1C20.1 1D10.1 1E11.1 2H09.1 2H13.1 2J06.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA PRIVACY LOCK MA321 QG 626 FAL

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 25

For use on door #(s):

1A15.1 1C08.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP/HOLDER FS495 626 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 26

For use on door #(s):

1C08.3

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

6 EA HINGE 5BB1 4.5 X 4.5 652 IVE

2 EA MANUAL FLUSH BOLT FB458 626 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA OH STOP 90S 630 GLY

2 EA SILENCER SR64 GRY IVE

Section 08 71 00 Page 40

Hardware Set No. 27

For use on door #(s):

1C08.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA WALL STOP WS406CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 28 - Sound Seals

For use on door #(s):

1C09.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 107NA CL NGP

1 EA DOOR BOTTOM 522N AL NGP

1 EA SADDLE THRESHOLD 413 719 NGP

Hardware Set No. 29 - Sound Seals

For use on door #(s):

1C09.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

6 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

2 EA MANUAL FLUSH BOLT FB458 626 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA OH STOP 90S J 630 GLY

1 SET SEALS 107NA CL NGP

2 EA ASTRAGAL 5070 BRN NGP

2 EA DOOR BOTTOM 522N AL NGP

1 EA SADDLE THRESHOLD 413 719 NGP

Section 08 71 00 Page 41

Hardware Set No. 30

For use on door #(s):

1C09.3

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

6 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 SET AUTO FLUSH BOLT FB41P 630 IVE

1 EA DUST PROOF STRIKE DP2 626 IVE

1 EA CLASSROOM LOCK MA561HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA COORDINATOR COR X FL 628 IVE

2 EA MOUNTING BRACKET MB 689 IVE

2 EA SURFACE CLOSER SC71 DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA ASTRAGAL 5070 BRN NGP

Hardware Set No. 31

For use on door #(s):

1D00.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

2 EA DUMMY PUSH BAR 250 626 FAL

2 EA SHEAR LOCK GF3000 DSM/MBS 335 SCE

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

2 EA SURFACE CLOSER SC71 DSHO 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

2 EA SILENCER SR64 GRY IVE

1 EA POWER SUPPLY PS902 FA900 KL900 LGR SCE

2 CARD READER BY OTHERS

DOOR OPERATION:

1. Door normally unlocked from both sides.

2. During building secure lock-down magnets can be remotely locked which will secure the doors.

3. During this time authorized access thru opening from either direction by valid card credential.

4. Magnets are also wired to fire alarm system and will release immediately upon fire alarm activation.

Section 08 71 00 Page 42

Hardware Set No. 32 - Classrooms

For use on door #(s):

1D03.1 1D05.1 1D07.1 1D09.1 1D11.1 1D13.1 1E01.1 1E03.1 1E05.1 1E09.1 2G01.1 2G02.1 2G04.1 2G08.1 2G10.1 2H02.1 2H02.2 2I01.1 2I03.1 2I05.1 2I09.1 2J01.1 2J03.1 2J07.1 2J09.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA OH STOP 90S 630 GLY

1 SET SEALS 5075B BRN NGP

1 EA DOOR BOTTOM 522N AL NGP

1 EA SADDLE THRESHOLD 413 719 NGP

Hardware Set No. 33 - Classrooms

For use on door #(s):

1E07.1 2I07.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 107NA CL NGP

1 EA DOOR BOTTOM 522N AL NGP

1 EA SADDLE THRESHOLD 413 719 NGP

Hardware Set No. 34

For use on door #(s):

2H00.1 2J00.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD EPT 628 IVE

2 EA POWER TRANSFER EPT10 689 VON

1 EA ELEC FIRE EXIT

HARDWARE

RX-FSA-F-25-V-L-LBR-QUA 626 FAL

1 EA ELEC FIRE EXIT

HARDWARE

RX-FSA-F-25-V-L-LBR-QUA 626 FAL

1 EA RIM HOUSING C953 626 FAL

Section 08 71 00 Page 43

2 EA SURFACE CLOSER SC71 DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA ASTRAGAL 5070 BRN NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS902 FA900 KL900 LGR SCE

1 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally closed and secure from the stair side of door.

2. Lever trim held in locked position by signal from fire alarm and will release upon fire alarm activation for immediate access to any floor.

3. Authorized entry onto floor by valid credential.

4. Request to exit in lock and door position switch to be connected to access control panel for monitoring.

5. Free egress from the push side of door at all times.

Hardware Set No. 35

For use on door #(s):

2H00.3

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD EPT 628 IVE

1 EA PASSAGE SET MA101 QG 626 FAL

1 EA SHEAR LOCK GF3000 DSM/MBS 335 SCE

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA POWER SUPPLY PS902 FA900 KL900 LGR SCE

2 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally unlocked from both sides.

2. During building secure lock-down magnets can be remotely locked which will secure the doors.

3. During this time authorized access thru opening from either direction by valid card credential.

4. Magnets are also wired to fire alarm system and will release immediately upon fire alarm activation.

Hardware Set No. 36

For use on door #(s):

1C05.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

1 EA PANIC HARDWARE CD-25-V-EO-LBR 626 FAL

1 EA PANIC HARDWARE CD-25-V-NL-OP-LBR 626 FAL

1 EA RIM HOUSING C953 626 FAL

2 EA MORTISE CYLINDER C987 626 FAL

Section 08 71 00 Page 44

3 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

2 EA SURFACE CLOSER SC71 DSHO 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

1 SET ASTRAGAL 140PA CL NGP

2 EA DOOR BOTTOM 522N AL NGP

1 EA SADDLE THRESHOLD 413 719 NGP

2 EA SILENCER SR64 GRY IVE

Hardware Set No. 37

For use on door #(s):

1E06.1 2G03.1 2G03.2 2G09.1 2G09.2 2I04.1 2I04.2 2I08.1 2I08.2 2J02.1 2J02.2 2J08.1 2J08.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA OH STOP 450S J 630 GLY

1 EA WALL STOP WS406CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 38

For use on door #(s):

1C16.1 2H10.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA STOREROOM LOCK MA581HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DSHO 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

3 EA SILENCER SR64 GRY IVE

Section 08 71 00 Page 45

Hardware Set No. 39

For use on door #(s):

1C14.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA OH STOP 90S J 630 GLY

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 40

For use on door #(s):

S2.2 S2.3 S3.2 S3.3

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD EPT 628 IVE

2 EA POWER TRANSFER EPT10 689 VON

2 EA ELEC FIRE EXIT

HARDWARE

RX-FSA-F-25-V-L-LBR-QUA 626 FAL

2 EA SURFACE CLOSER SC71 DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA ASTRAGAL 5070 BRN NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS902 FA900 KL900 LGR SCE

1 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally closed and secure from the stair side of door.

2. Lever trim held in locked position by signal from fire alarm and will release upon fire alarm activation for immediate access to any floor.

3. Authorized entry onto floor by valid credential.

4. Request to exit in lock and door position switch to be connected to access control panel for monitoring.

5. Free egress from the push side of door at all times.

Section 08 71 00 Page 46

Hardware Set No. 41

For use on door #(s):

1F04.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA STOREROOM LOCK MA581HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 5075B BRN NGP

Hardware Set No. 42

For use on door #(s):

S1.2 S1.3

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD EPT 628 IVE

1 EA POWER TRANSFER EPT10 689 VON

1 EA ELEC FIRE EXIT

HARDWARE

RX-FSA-F-25-R-L-QUA 626 FAL

1 EA SURFACE CLOSER SC71 RW/PA 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA POWER SUPPLY PS902 FA900 KL900 LGR SCE

1 EA CARD READER FURNISHED BY SECURITY VENDOR

DOOR OPERATION:

1. Door normally closed and secure from the stair side of door.

2. Lever trim held in locked position by signal from fire alarm and will release upon fire alarm activation for immediate access to any floor.

3. Authorized entry onto floor by valid credential.

4. Request to exit in lock and door position switch to be connected to access control panel for monitoring.

5. Free egress from the push side of door at all times.

Section 08 71 00 Page 47

Hardware Set No. 43

For use on door #(s):

1A15.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DSHO 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 44 - Classrooms

For use on door #(s):

1C10.1 2H06.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA WALL STOP WS406CCV 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA DOOR BOTTOM 522N AL NGP

1 EA SADDLE THRESHOLD 413 719 NGP

Hardware Set No. 45

For use on door #(s):

S1.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

2 EA FIRE EXIT HARDWARE F-25-V-L-LBR-QUA 626 FAL

2 EA RIM HOUSING C953 626 FAL

2 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

2 EA SURFACE CLOSER SC71 DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

Section 08 71 00 Page 48

Hardware Set No. 46

For use on door #(s):

2H02.3

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA CLASSROOM LOCK MA561HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

Hardware Set No. 47

For use on door #(s):

1C10.2 1C25.1 1D03.2 1D05.2 1D07.2 1D09.2 1D11.2 1D13.2 1E01.2 1E03.2 1E05.2 1E07.2 1E09.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA PASSAGE SET MA101 QG 626 FAL

1 EA WALL STOP WS406CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 48

For use on door #(s):

1E00.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD EPT 628 IVE

2 EA POWER TRANSFER EPT10 689 VON

1 EA ELEC PANIC

HARDWARE

RX-EL-25-V-EO-LBR 626 FAL

1 EA ELEC PANIC

HARDWARE

RX-EL-25-V-NL-OP-LBR 626 FAL

1 EA RIM HOUSING C953 626 FAL

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

2 EA SURFACE CLOSER SC71 DSHO 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

2 EA SILENCER SR64 GRY IVE

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS914 900-2RS LGR VON

1 EA CARD READER FURNISHED BY SECURITY VENDOR

Section 08 71 00 Page 49

DOOR OPERATION:

1. Door normally closed and secure.

2. Entry from secure side by valid credential or key override which will unlock electrified door.

3. Free egress from inside at all times.

4. Door position switch and request to exit connected to access control system for monitoring.

Hardware Set No. 49

For use on door #(s):

1C26.2

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA PRIVACY LOCK MA321 QG 626 FAL

1 EA WALL STOP WS406CCV 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 50

For use on door #(s):

1C26.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

1 EA PASSAGE SET MA101 QG 626 FAL

1 EA OH STOP 90S J 630 GLY

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 51

For use on door #(s):

2I00.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA CONT. HINGE 224HD 628 IVE

2 EA FIRE EXIT HARDWARE F-25-V-L-BE-LBR-QUA 626 FAL

1 EA RIM HOUSING C953 626 FAL

2 EA SHEAR LOCK GF3000 DSM/MBS 335 SCE

2 EA SURFACE CLOSER SC71 DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

1 SET SEALS 5075B BRN NGP

1 EA ASTRAGAL 5070 BRN NGP

2 EA DOOR CONTACT 679-05HM BLK SCE

1 EA POWER SUPPLY PS902 FA900 KL900 LGR SCE

1 EA CARD READER FURNISHED BY SECURITY VENDOR

Section 08 71 00 Page 50

DOOR OPERATION:

1. Door normally unlocked from both sides.

2. During building secure lock-down magnets can be remotely locked which will secure the doors.

3. During this time authorized access thru opening from either direction by valid card credential.

4. Magnets are also wired to fire alarm system and will release immediately upon fire alarm activation.

Hardware Set No. 52

For use on door #(s):

2G00.1 2G00.2 2H00.2 2H01.2 2J04.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HW HINGE 5BB1HW 4.5 X 4.5 NRP 630 IVE

1 EA CLASSROOM LOCK MA561HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 SS 689 FAL

1 EA THRESHOLD 896S AL NGP

1 EA DOOR CONTACT 679-05HM BLK SCE

Hardware Set No. 53

For use on door #(s):

2H02.4

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

2 EA SPRING HINGE 3SP1 4.5 X 4.5 652 IVE

4 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 SET CONST LATCHING

BOLT

FB62 630 IVE

1 EA CLASSROOM LOCK MA561HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA COORDINATOR COR X FL 628 IVE

1 EA MOUNTING BRACKET MB 689 IVE

1 EA SURFACE CLOSER SC71 DEL DS 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

Section 08 71 00 Page 51

Hardware Set No. 54

For use on door #(s):

1A11.2

Provide each DD door(s) with the following:

Qty Description Catalog Number Finish Mfr

4 EA HINGE 5BB1 4.5 X 4.5 652 IVE

1 EA DUTCH DOOR BOLT 054 626 IVE

1 EA PASSAGE TIME-OUT

LOCK

L9010 per XL12-631 RHR 626 SCH

1 EA WALL STOP/HOLDER FS495

(Mount wall holder near top of upper door leaf)

626 IVE

1 EA WALL STOP WS406CCV 630 IVE

4 EA SILENCER SR64 GRY IVE

Hardware Set No. 55

For use on door #(s):

2H05.1

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

3 EA HINGE 5BB1 4.5 X 4.5 NRP 652 IVE

1 EA DORMITORY/OFFICE

LOCK

MA571HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 DS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

3 EA SILENCER SR64 GRY IVE

Hardware Set No. 56

For use on door #(s):

1C03.1

Provide each PR door(s) with the following:

Qty Description Catalog Number Finish Mfr

6 EA HW HINGE 5BB1HW 4.5 X 4.5 652 IVE

2 EA DUMMY PUSH BAR 250 626 FAL

2 EA SHEAR LOCK MAGNET GF3000 DSM/MBS 628 SCE

2 EA 90 DEG OFFSET PULL 8190 10" O 630 IVE

1 EA SURFACE CLOSER SC71 DSHO 689 FAL

1 EA SURFACE CLOSER SC71 HDPA 689 FAL

2 EA KICK PLATE 8400 10" X 1" LDW B4E 630 IVE

2 EA FIRE/LIFE WALL MAG SEM7850 689 LCN

1 SET SEALS 5075B BRN NGP

1 EA ASTRAGAL 5070 BRN NGP

1 EA POWER SUPPLY PS902 FA900 KL900 LGR SCE

2 EA CARD READER FURNISHED BY SECURITY VENDOR

Section 08 71 00 Page 52

DOOR OPERATION:

1. Doors normally unlock and push pull operation.

2. Doors held open on wall magnets connected to fire alarm system.

3. In lock down mode door will close and security magnets will hold doors secure.

4. Card reader on either side will momentarily release security magnet for passage.

5. Security magnets connected to fire alarm system for immediate release.

Hardware Set No. 57

For use on door #(s):

S1.4

Provide each SGL door(s) with the following:

Qty Description Catalog Number Finish Mfr

1 EA CONT. HINGE 224HD 628 IVE

1 EA STORE DOOR LOCK MA371HD7 QG 626 FAL

1 EA PERMANENT KEYED

CORE

TO MATCH EXISTING KEY SYSTEM 626 FAL

1 EA SURFACE CLOSER SC71 SS 689 FAL

1 EA KICK PLATE 8400 10" X 2" LDW B4E 630 IVE

1 SET SEALS 5050B BRN NGP

1 EA THRESHOLD 896S AL NGP

1 EA DOOR CONTACT 679-05HM BLK SCE

DOOR OPERATION:

1. Door position switch to be connected to access control system for monitoring.

-- End of Section --

SECTION SF 30 BLOCK 14 CONTINUATION PAGE.pdf
A. PROPOSAL SUBMISSION (Section L)
NOTE: All pages, including cover letters, table of contents pages, tables, illustrations and appendices (but not tabs) and past performance information submitted in support of the proposal will be considered in the page calculation. Cross-referencing...
B. DISCUSSIONS
D. FACTORS TO BE EVALUATED
FACTOR 1 – TECHNICAL EXPERIENCE
FACTOR 2 –MANAGEMENT PLAN
FACTOR 3 – PAST PERFORMANCE
FACTOR 4 - SMALL BUSINESS PARTICIPATION:
E. EVALUATION APPROACH
Table 4. Small Business Participation Factor Rating Definitions
FACTOR 5. PRICE
FINAL SELECTION
APPENDIX A
TO BE COMPLETED BY CLIENT
Please provide responses to the questions above (if applicable) and additional remarks. Furthermore, please provide a brief narrative addressing specific strengths, weaknesses, deficiencies, or other comments which may assist our office in evaluating ...
APPENDIX B
(c) Please indicate the total percentage of participation to be performed by each type of subcategory small business. The percentage of work performed by Small Businesses that qualify in multiple small business categories may be counted in each category:
(d) List principle supplies/services to be performed by each Small Business category (Not providing supplies/services for each category will result in a weakness). Also include the subcontractors Cage Code and Duns Number:
Additional Important Note for Other than U.S. Small Businesses ONLY (i.e. Large Businesses).
APPENDIX C
APPENDIX D

File details come from the government source that posted it. Updated .