W912QR21R0013_Plans_Vol8-0002.pdf

PDF 3 MB Posted

Attached to
Family Housing Renovation at WPAFB, OH
Solicitation number
W912QR21R0013
Issued by

About this file

This solicitation announcement is for a firm-fixed-price construction contract to renovate 29 family housing units at Wright-Patterson Air Force Base in Dayton, Ohio. Renovations will include modernizing and repairing building exteriors, systems, and interiors. Work includes functional improvements such as kitchen, bathroom and closet reconfigurations as well as additions to provide more living space and replacing one-car with two-car garages. The project magnitude is estimated between $25-100 million. The selection process will use a best value tradeoff evaluation of past performance, technical and price factors. The Corps of Engineers Louisville District is the issuing agency. The response due date is not provided as this is an advance notice only.

View the file

Other files

File Type Posted
W912QR21R0013_Plans_Vol8-0003.pdf PDF
W912QR21R0013_Plans_Vol1-0003.pdf PDF
W912QR21R0013_Plans_Vol4-0003.pdf PDF
W912QR21R0013_Plans_Vol6-0003.pdf PDF
W912QR21R0013_Specs_Vol1-0003.pdf PDF
W912QR21R0013_Plans_Vol2-0003.pdf PDF
W912QR21R0013_Plans_Vol5-0003.pdf PDF
W912QR21R0013_Plans_Vol3-0003.pdf PDF
W912QR21R0013_Plans_Vol7-0003.pdf PDF
W912QR21R0013_Plans_Vol3-0002.pdf PDF
W912QR21R0013_Plans_Vol6-0002.pdf PDF
W912QR21R0013_Plans_Vol2-0002.pdf PDF
W912QR21R0013_Plans_Vol4-0002.pdf PDF
W912QR21R0013_Plans_Vol9-0002.pdf PDF
W912QR21R0013_Plans_Vol7-0002.pdf PDF
W912QR21R0013_Specs_Vol1-0002.pdf PDF
W912QR21R0013_Plans_Vol5-0002.pdf PDF
W912QR21R0013_Plans_Vol2-0001.pdf PDF
W912QR21R0013_Plans_Vol9-0001.pdf PDF
W912QR21R0013_Plans_Vol1-0001.pdf PDF
Site Visit Roster.pdf PDF
W912QR21R0013_Specs_Vol1-0001.pdf PDF
W912QR21R0013_Plans_Vol4-0000.pdf PDF
W912QR21R0013_Plans_Vol2-0000.pdf PDF
W912QR21R0013_Specs_Vol1-0000.pdf PDF
W912QR21R0013_Specs_Vol3-0000.pdf PDF
W912QR21R0013_Plans_Vol5-0000.pdf PDF
W912QR21R0013_SWPPP-0000.pdf PDF
W912QR21R0013_Plans_Vol9-0000.pdf PDF
W912QR21R0013_SID-0000.pdf PDF
W912QR21R0013_Plans_Vol7-0000.pdf PDF
W912QR21R0013_Boring_Logs-0000.pdf PDF
W912QR21R0013_Plans_Vol1-0000.pdf PDF
W912QR21R0013_Plans_Vol8-0000.pdf PDF
W912QR21R0013_Plans_Vol3-0000.pdf PDF
W912QR21R0013_Plans_Vol6-0000.pdf PDF
W912QR21R0013_Specs_Vol2-0000.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

161 SF

STORAGE

362 SF

MECH RM

195 SF

LAUNDRY

CRAWL SPACE

CRAWL SPACE

H

H

I

29 29

A. DOCUMENT MOLDING TYPE AND LOCATION AND SALVAGE AND PROTECT A 24”

SECTION OF EACH TYPE, TYPICAL. RETAIN FOR SHPO.

B. DEMOLISH ALL EXISTING CABINETS, COUNTERTOPS, APPLIANCES, SINKS, AND

SHELVING THROUGHOUT.

C. DEMOLISH EXISTING CASEWORK AND BUILT-INS, DOCUMENT BUILT-INS PRIOR TO

DEMOLITION WITH PHOTO DOCUMENTATION ORGANIZED BY ADDRESS AND UNIT

TYPE, DIGITAL COPIES PROVIDED TO BASE HOUSING, ARCHITECT AND SHPO.

D. DEMOLISH ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT AND

FIXTURES COMPLETE, INCLUDING RADIATORS, BATHTUBS, SINKS, AND TOILETS

SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR FURTHER

INFORMATION.

E. DEMOLISH EXISTING PLASTER/ GYPSUM BOARD AND WALL FINISH, WALL BASE,

AND MOLDING ON ALL WALLS REQUIRING ELECTRICAL WORK AND ALL EXTERIOR

WALLS, DEMOLISH BATT INSULATION AT EXTERIOR WALLS.

F. DEMOLISH EXISTING FLOORING AND FASTENERS COMPLETE, CLEAN AND PREP

FOR NEW FINISHES.

G. DEMOLISH EXISTING CEILING COMPLETE INCLUDING INSULATION, DIFFUSERS,

RETURNS, AND LIGHTS.

H. REMOVE ALL EXISTING WINDOWS, CASEMENT AND TRIM INSPECT OPENING FOR

WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER TO

WINDOW SCHEDULES SHEET A601 FOR LOCATIONS REQUIRING REPLACEMENT

OF DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING COORDINATE WITH

STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT FRAMING AND

BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE WITH NEW AT EACH

LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE BREAKS IN THE

ENVELOPE.

I. REMOVE ALL BASEMENT WINDOWS, CASEMENT AND TRIM INSPECT OPENING

FOR WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER

TO WINDOW SCHEDULES SHEET A603 FOR LOCATIONS REQUIRING

REPLACEMENT OF DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING

COORDINATE WITH STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT

FRAMING AND BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE

WITH NEW AT EACH LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE

BREAKS IN THE ENVELOPE.

J. EXISTING TILE ROOF, UNDERLAYMENT, FLASHING, GUTTERS AND DOWNSPOUTS

TO BE REMOVED COMPLETE. CONTRACTOR TO INSPECT ALL EAVE AND GABLE

FASCIA, TRIM, AND ROOF SHEATHING AND REPLACE ALL DAMAGED MATERIAL TO

MATCH EXISTING ADJACENT; CONTRACTOR TO PROVIDE AN ALLOWANCE FOR

DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING BOARDS AND (8) EACH OF

8FT TRIM AND FASCIA BOARDS TO MATCH EXISTING ADJACENT CONSTRUCTION

PER BUILDING IN BASE BID NOTE: ALL DECORATIVE STRAPS AND SCUPPER

BOXES TO BE PROTECTED AND SALVAGED FOR REINSTALLATION.

K. EXISTING SCREENED IN PORCH ENCLOSURES TO BE DEMOLISHED COMPLETE.

REFER TO CIVIL FOR LOCATION AND QUANTITY OF SCREENED IN PORCHES TO

BE DEMOLISHED.

L. CONTRACTOR TO RETAIN UNDAMAGED BRICK FOR INFILLING OPERATIONS.

M. ALL METAL AND COPPER DEMOLISHED MUST GO TO RECYCLING CENTER,

COORDINATE BASE ENVIRONMENTAL OFFICE.

N. CONTRACTOR TO SALVAGE A 2’X2’ SECTION OF THE PLASTER WALL SYSTEM

COMPLETE AND RETAIN FOR SHPO.

O. REMOVE CLEAN AND PREP FOR RE-INSTALLATION ALL LOOSE BRICK/ PAVER &

STONEWORK. REMOVE ALL LOOSE AND SPRAWLING GROUT AND BASE @

EXISTING FRONT PORCH AND STAIR TO SOLID SUB STRUCTURE, PREP SURFACE

FOR REINSTALLATION STONEWORK TO MATCH EXISTING ADJACENT SURFACE

LEVEL. INSPECT HANDRAIL SYSTEM FOR LOOSE OR UNSTABLE CONDITIONS

REMOVE, STRIP OF FINISHES AND PREP FOR REINSTALLATION EXISTING LOOSE

OR UNSTABLE HANDRAIL SYSTEMS COMPLETE. CONTRACTOR TO MINIMIZE

DAMAGE TO SURROUNDING SURFACES TO REMAIN. AND PROVIDE ALLOWANCE

FOR 27 SF OF PORCH AND STAIR STONEWORK PER RESIDENCE ADDRESS TO BE

REMOVED AND REINSTALLED IN BASE BID. NOTE: CONTRACTOR TO PROVIDE

ALLOWANCE FOR REMOVAL AND REINSTALLATION OF ALL EXTERIOR HANDRAIL

SYSTEMS ON 10 RESIDENCES IN BASE BID. ALLOWANCE TO BE APPLIED

AS REQUIRED.

P. DEMOLISH METAL AWNINGS, FRAMES AND MOUNTING HARDWARE @ WINDOWS

AND FRONT PORCH COMPLETE. CONTRACTOR TO TUCKPOINT ALL

PENETRATIONS IN GROUT AND REPLACE ALL DAMAGED BRICK AT MOUNTING

LOCATIONS.

EXISTING WALL TO

REMAIN

EXISTING WALL TO BE

DEMOLISHED

EXISTING DOOR TO

REMAIN

EXISTING DOOR TO BE

DEMOLISHED

DEMOLISH PORTION OF WALL AS SHOWN, PROVIDE SHORING PRIOR TO

DEMOLITION AS REQUIRED. SHORING TO BE CONTINUOUS TO FOUNDATION

BELOW, COORDINATE WITH STRUCTURAL DRAWINGS.

DEMO PORTION OF WALL COMPLETE TO DIMENSION SHOWN.

DEMOLISH EXISTING INTERIOR STAIR HANDRAILS AND PICKETS, SALVAGE AND

PROTECT A 24” SECTION, RETAIN FOR SHPO.

DEMOLISH ALL EXISTING CABINETS, COUNTERTOPS, APPLIANCES, SINKS &

SHELVING & BUILT-INS THROUGHOUT, SEE DEMO NOTES A, B & C FOR FURTHER

INFORMATION.

DEMOLISH EXISTING HEARTH TILE AND MANTLE, TRIM, AND GAS LOGS, SALVAGE

GAS LOGS FOR REINSTALLATION, COORDINATE WITH MECHANICAL AND

ELECTRICAL FOR REWORK OF HOOKUPS.

DEMOLISH EXISTING DOOR AND HARDWARE COMPLETE.

DEMOLISH EXISTING WALL AS SHOWN.

REMOVE EXISTING DOOR, SALVAGE DOOR AND ALL HARDWARE FOR

REINSTALLATION. RE-FINISH AND REPAIR SALVAGED DOOR, RESTORE HARDWARE,

WEATHERSTRIPPING AND SWEEP AND REPLACE THE LOWER VERTICAL

(APPROX. 7 FT) OF HINGE AND LATCH JAMB BOARDS WITH NEW WOOD TO MATCH

EXISTING, MORTISE HINGES AND LATCH HARDWARE AS REQUIRED. PROVIDE 1

PRIMER AND 2 FINISH COATS OF PAINT. CONTRACTOR TO PROVIDE ALLOWANCE

FOR (2) 7' 2X6 JAMB BOARDS IN BASE BID, TO BE CUT TO FIT AS REQUIRED TO

MATCH EXISTING. FIELD MEASURE SIZE REQUIRED. SEE FINISH AND DOOR SCHED.

FOR MORE INFORMATION

DEMOLISH EXISTING STORM DOOR FRAME AND HARDWARE COMPLETE.

DEMOLISH EXISTING METAL WINDOW AWNING, FLASHING AND FRAMING AND

FASTENERS COMPLETE, SEE GENERAL NOTE “P” FOR FURTHER INFORMATION.

DEMOLISH EXISTING METAL FRONT PORCH ROOF, FLASHING AND FRAMING

COMPLETE, DEMO GUTTER AND DOWNSPOUT, PREP FOR NEW ROOF FRAMING,

COORDINATE WITH STRUCTURAL, SEE GENERAL NOTE “P” FOR FURTHER

INFORMATION.

DEMOLISH EXISTING PORCH COPPER ROOF AND FLASHING COMPLETE TO

SHEATHING, DEMO GUTTER AND DOWNSPOUT, INSPECT SHEATHING FOR

DAMAGED MATERIALS AND REPLACE ALL DAMAGED MATERIAL WITH MATCHING

MATERIAL SIZE AND DIM. PREPARE FOR NEW FINISHES. NOTE CONTRACTOR TO

PROVIDE ALLOWANCE FOR DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING

BOARDS TO MATCH EXISTING ADJACENT, PER RESIDENCE IN BASE BID

DEMOLISH EXISTING CONCRETE WALK AND PATIO COMPLETE. SEE CIVIL

DRAWINGS FOR SCOPE OF WORK.

DEMO EXISTING DORMER SIDING AND ROOFING, FLASHING AND UNDERLAYMENT.

INSPECT SHEATHING FOR DAMAGE AND REMOVE ALL DAMAGED MATERIAL, AND

PREP WINDOW OPENING FOR NEW FRAMING. NOTE: SCHEDULE THIS WORK SO AS

TO REPLACE WITH NEW AT EACH LOCATION ONCE AREA IS REPAIRED, SO AS TO

MINIMIZE BREAKS IN THE BUILDING ENVELOPE. CONTRACTOR TO PROVIDE

ALLOWANCE FOR DEMO AND REPLACEMENT OF ALL WINDOW SILL FRAMING AND

(4) 8FT 1x8 WALL SHEATHING AND (4) 8FT FACIA AND TRIM BOARDS TO MATCH

EXISTING PER DORMER AND TYPICAL FOR EACH RESIDENCE ADDRESS IN BASE

BID.

DEMOLISH PORTION OF WALLS AS SHOWN, PROVIDE SHORING PRIOR TO

DEMOLITION AS REQUIRED. SHORING TO BE CONTINUOUS TO FOUNDATION

BELOW OR NEARBY ADJACENT LOADBEARING STRUCTURE, COORDINATE WITH

STRUCTURAL DRAWINGS.

EXISTING METAL CHIMNEY FLUE SCREEN/CAP TO BE REMOVED AND PREP FOR

NEW SCREEN/CAP.

REMOVE ALL EXISTING WINDOWS, CASEMENT AND TRIM INSPECT OPENING FOR

WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER TO

WINDOW SCHEDULES SHEET A603 FOR LOCATIONS REQUIRING REPLACEMENT OF

DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING COORDINATE WITH

STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT FRAMING AND

BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE WITH NEW AT EACH

LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE BREAKS IN THE

ENVELOPE.

NOTES 18- 24 ARE UNIT AND ADDRESS SPECIFIC REGARDING ABATEMENT

SEE SPEC TABLE 01 02 20 FOR ABETMENT QUANTITIES

ABATE ASSUMED ASBESTOS-CONTAINING VIBRATION DAMPER (733 PEARSON, 447

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASSUMED ASBESTOS-CONTAINING CERAMIC FLOOR TILE WITH

MORTAR/MASTIC AND GROUT (733 PEARSON, 419 JOHNSON, 447 JOHNSON, 523

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASSUMED ASBESTOS-CONTAINING CERAMIC WALL TILE WITH

MORTAR/MASTIC AND GROUT (733 PEARSON, 419 JOHNSON, 447 JOHNSON, 523

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASBESTOS-CONTAINING GRAY FLOOR LEVELER (733 PEARSON).

ABATE ASBESTOS-CONTAINING YELLOW MASTIC/FLOOR LEVELER (447 JOHNSON).

ABATE ASBESTOS-CONTAINING 12"X12" TAN FLOOR TILE WITH BLACK MASTIC (523

JOHNSON).

ABATE ASBESTOS-CONTAINING 9"X9" BLACK FLOOR TILE WITH NON-ASBESTOS-

CONTAINING BLACK MASTIC (420 METZGER).

DEMOLISH ALL LOOSE BRICK/ PAVER & STONEWORK & HANDRAIL SYSTEMS AT

FRONT PORCH AND STAIR AND PREP FOR REINSTALLATION SEE DEMO NOTE “O”

FOR FURTHER INFORMATION.

DEMOLISH EXISTING SHEATHING AT HIP CRICKET AT CHIMNEY/ ROOF AREA

COMPLETE TO MAIN ROOF AND ENTRY GABLE INTERSECTION. RE-FRAME NEW

VALLEY CRICKET. MAINTAIN EXISTING EAVE COORDINATE WITH STRUCTURAL FOR

FURTHER INFORMATION.

DEMOLISH ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT AND

FIXTURES COMPLETE, INCLUDING RADIATORS, BATHTUBS, SINKS, AND TOILETS

SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR FURTHER

INFORMATION.

EXISTING WINDOW WELL COVER / MOUNTING

HARDWARE AND FRAME TO BE REMOVED

COMPLETE. CONTRACTOR TO DOCUMENT

SIZE AND PROFILE FOR REPLACEMENT

COVER TO MATCH DEMOLISHED.

CLEAN ALL EXTERIOR FOUNDATION BASEMENT WALLS. STRIP INTERIOR FACE OF

ALL FINISHES TO EXPOSE CONCRETE. PREP SURFACE AND TREAT WITH

CEMENTITIOUS WATER-PROOFING. FINISHED BASEMENT AREAS INSTALL 2X

FURRING AND SHIM AS REQUIRED FOR STRAIGHT SMOOTH AND PLUMB SURFACE.

INSTALL 1/2" GWB SHEATHING AND

SCHEDULED FINISH AS INDICATED.

EXISTING TILE ROOF, UNDERLAYMENT, FLASHING, GUTTERS AND DOWNSPOUTS

TO BE REMOVED COMPLETE. CONTRACTOR TO INSPECT ALL EAVE AND GABLE

FASCIA, TRIM, AND ROOF SHEATHING AND REPLACE ALL DAMAGED MATERIAL TO

MATCH EXISTING ADJACENT; CONTRACTOR TO PROVIDE AN ALLOWANCE FOR

DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING BOARDS & (4) 8FT FACIA

AND TRIM BOARDS TO MATCH EXISTING TO BE REPLACED IN BASE BID NOTE: ALL

DECORATIVE STRAPS AND SCUPPER BOXES TO BE PROTECTED AND SALVAGED

FOR REINSTALLATION

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

AD101

B A

S E

M E

N T

D E

M O

L

IT

IO

N

P L

A N

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

D A

Y T

O N

O

H

IO

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J W

IL

K

E R

S O

N

N B

E R

B E

R

IC

H

S D

E G

A R

O

R C

U R

R A

N

J A

N U

A R

Y

W Q

R -1

-F

-0

CERTIFIED FINAL FOR CONSTRUCTION

IM

P

R O

V E

F A

M

IL

Y H

O U

S

IN

G

P

F

IL

E N

U M

B E

R

TYPE G

GENERAL NOTES:

KEYNOTES

LEGEND

1/4" = 1'-0"A2

BASEMENT DEMOLITION PLAN

0 2' 4' 8'

A m e n d m e n t

M

A R

C H

KEYNOTES CONTINUED

03/10/21 W

2Q R

R

-0

DN

DN

DW

212 SF

LIVING RM

29 SF

BATH 3

62 SF

BATH 1

215 SF

BEDROOM 1

96 SF

FOYER

PORCH

L2

L1

L3

KITCHEN

DINING

FAMILY

HALL

CLOSET

BATH 1

DEMOLISH COLUMNS

B

B

B

B

A A E EE

D

A

A

BBCCC

C

BBB

FROM EDGE

OF EXISTING

OPENING

SEE GENERAL DEMOLITION NOTE

"O" FOR WORK THIS AREA.

SEE GENERAL DEMOLITION NOTE

"O" FOR WORK THIS AREA.

A. DOCUMENT MOLDING TYPE AND LOCATION AND SALVAGE AND PROTECT A 24”

SECTION OF EACH TYPE, TYPICAL. RETAIN FOR SHPO.

B. DEMOLISH ALL EXISTING CABINETS, COUNTERTOPS, APPLIANCES, SINKS, AND

SHELVING THROUGHOUT.

C. DEMOLISH EXISTING CASEWORK AND BUILT-INS, DOCUMENT BUILT-INS PRIOR TO

DEMOLITION WITH PHOTO DOCUMENTATION ORGANIZED BY ADDRESS AND UNIT

TYPE, DIGITAL COPIES PROVIDED TO BASE HOUSING, ARCHITECT AND SHPO.

D. DEMOLISH ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT AND

FIXTURES COMPLETE, INCLUDING RADIATORS, BATHTUBS, SINKS, AND TOILETS

SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR FURTHER

INFORMATION.

E. DEMOLISH EXISTING PLASTER/ GYPSUM BOARD AND WALL FINISH, WALL BASE,

AND MOLDING ON ALL WALLS REQUIRING ELECTRICAL WORK AND ALL EXTERIOR

WALLS, DEMOLISH BATT INSULATION AT EXTERIOR WALLS.

F. DEMOLISH EXISTING FLOORING AND FASTENERS COMPLETE, CLEAN AND PREP

FOR NEW FINISHES.

G. DEMOLISH EXISTING CEILING COMPLETE INCLUDING INSULATION, DIFFUSERS,

RETURNS, AND LIGHTS.

H. REMOVE ALL EXISTING WINDOWS, CASEMENT AND TRIM INSPECT OPENING FOR

WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER TO

WINDOW SCHEDULES SHEET A601 FOR LOCATIONS REQUIRING REPLACEMENT

OF DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING COORDINATE WITH

STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT FRAMING AND

BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE WITH NEW AT EACH

LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE BREAKS IN THE

ENVELOPE.

I. REMOVE ALL BASEMENT WINDOWS, CASEMENT AND TRIM INSPECT OPENING

FOR WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER

TO WINDOW SCHEDULES SHEET A603 FOR LOCATIONS REQUIRING

REPLACEMENT OF DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING

COORDINATE WITH STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT

FRAMING AND BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE

WITH NEW AT EACH LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE

BREAKS IN THE ENVELOPE.

J. EXISTING TILE ROOF, UNDERLAYMENT, FLASHING, GUTTERS AND DOWNSPOUTS

TO BE REMOVED COMPLETE. CONTRACTOR TO INSPECT ALL EAVE AND GABLE

FASCIA, TRIM, AND ROOF SHEATHING AND REPLACE ALL DAMAGED MATERIAL TO

MATCH EXISTING ADJACENT; CONTRACTOR TO PROVIDE AN ALLOWANCE FOR

DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING BOARDS AND (8) EACH OF

8FT TRIM AND FASCIA BOARDS TO MATCH EXISTING ADJACENT CONSTRUCTION

PER BUILDING IN BASE BID NOTE: ALL DECORATIVE STRAPS AND SCUPPER

BOXES TO BE PROTECTED AND SALVAGED FOR REINSTALLATION.

K. EXISTING SCREENED IN PORCH ENCLOSURES TO BE DEMOLISHED COMPLETE.

REFER TO CIVIL FOR LOCATION AND QUANTITY OF SCREENED IN PORCHES TO

BE DEMOLISHED.

L. CONTRACTOR TO RETAIN UNDAMAGED BRICK FOR INFILLING OPERATIONS.

M. ALL METAL AND COPPER DEMOLISHED MUST GO TO RECYCLING CENTER,

COORDINATE BASE ENVIRONMENTAL OFFICE.

N. CONTRACTOR TO SALVAGE A 2’X2’ SECTION OF THE PLASTER WALL SYSTEM

COMPLETE AND RETAIN FOR SHPO.

O. REMOVE CLEAN AND PREP FOR RE-INSTALLATION ALL LOOSE BRICK/ PAVER &

STONEWORK. REMOVE ALL LOOSE AND SPRAWLING GROUT AND BASE @

EXISTING FRONT PORCH AND STAIR TO SOLID SUB STRUCTURE, PREP SURFACE

FOR REINSTALLATION STONEWORK TO MATCH EXISTING ADJACENT SURFACE

LEVEL. INSPECT HANDRAIL SYSTEM FOR LOOSE OR UNSTABLE CONDITIONS

REMOVE, STRIP OF FINISHES AND PREP FOR REINSTALLATION EXISTING LOOSE

OR UNSTABLE HANDRAIL SYSTEMS COMPLETE. CONTRACTOR TO MINIMIZE

DAMAGE TO SURROUNDING SURFACES TO REMAIN. AND PROVIDE ALLOWANCE

FOR 27 SF OF PORCH AND STAIR STONEWORK PER RESIDENCE ADDRESS TO BE

REMOVED AND REINSTALLED IN BASE BID. NOTE: CONTRACTOR TO PROVIDE

ALLOWANCE FOR REMOVAL AND REINSTALLATION OF ALL EXTERIOR HANDRAIL

SYSTEMS ON 10 RESIDENCES IN BASE BID. ALLOWANCE TO BE APPLIED

AS REQUIRED.

P. DEMOLISH METAL AWNINGS, FRAMES AND MOUNTING HARDWARE @ WINDOWS

AND FRONT PORCH COMPLETE. CONTRACTOR TO TUCKPOINT ALL

PENETRATIONS IN GROUT AND REPLACE ALL DAMAGED BRICK AT MOUNTING

LOCATIONS.

EXISTING WALL TO

REMAIN

EXISTING WALL TO BE

DEMOLISHED

EXISTING DOOR TO

REMAIN

EXISTING DOOR TO BE

DEMOLISHED

DEMOLISH PORTION OF WALL AS SHOWN, PROVIDE SHORING PRIOR TO

DEMOLITION AS REQUIRED. SHORING TO BE CONTINUOUS TO FOUNDATION

BELOW, COORDINATE WITH STRUCTURAL DRAWINGS.

DEMO PORTION OF WALL COMPLETE TO DIMENSION SHOWN.

DEMOLISH EXISTING INTERIOR STAIR HANDRAILS AND PICKETS, SALVAGE AND

PROTECT A 24” SECTION, RETAIN FOR SHPO.

DEMOLISH ALL EXISTING CABINETS, COUNTERTOPS, APPLIANCES, SINKS &

SHELVING & BUILT-INS THROUGHOUT, SEE DEMO NOTES A, B & C FOR FURTHER

INFORMATION.

DEMOLISH EXISTING HEARTH TILE AND MANTLE, TRIM, AND GAS LOGS, SALVAGE

GAS LOGS FOR REINSTALLATION, COORDINATE WITH MECHANICAL AND

ELECTRICAL FOR REWORK OF HOOKUPS.

DEMOLISH EXISTING DOOR AND HARDWARE COMPLETE.

DEMOLISH EXISTING WALL AS SHOWN.

REMOVE EXISTING DOOR, SALVAGE DOOR AND ALL HARDWARE FOR

REINSTALLATION. RE-FINISH AND REPAIR SALVAGED DOOR, RESTORE HARDWARE,

WEATHERSTRIPPING AND SWEEP AND REPLACE THE LOWER VERTICAL

(APPROX. 7 FT) OF HINGE AND LATCH JAMB BOARDS WITH NEW WOOD TO MATCH

EXISTING, MORTISE HINGES AND LATCH HARDWARE AS REQUIRED. PROVIDE 1

PRIMER AND 2 FINISH COATS OF PAINT. CONTRACTOR TO PROVIDE ALLOWANCE

FOR (2) 7' 2X6 JAMB BOARDS IN BASE BID, TO BE CUT TO FIT AS REQUIRED TO

MATCH EXISTING. FIELD MEASURE SIZE REQUIRED. SEE FINISH AND DOOR SCHED.

FOR MORE INFORMATION

DEMOLISH EXISTING STORM DOOR FRAME AND HARDWARE COMPLETE.

DEMOLISH EXISTING METAL WINDOW AWNING, FLASHING AND FRAMING AND

FASTENERS COMPLETE, SEE GENERAL NOTE “P” FOR FURTHER INFORMATION.

DEMOLISH EXISTING METAL FRONT PORCH ROOF, FLASHING AND FRAMING

COMPLETE, DEMO GUTTER AND DOWNSPOUT, PREP FOR NEW ROOF FRAMING,

COORDINATE WITH STRUCTURAL, SEE GENERAL NOTE “P” FOR FURTHER

INFORMATION.

DEMOLISH EXISTING PORCH COPPER ROOF AND FLASHING COMPLETE TO

SHEATHING, DEMO GUTTER AND DOWNSPOUT, INSPECT SHEATHING FOR

DAMAGED MATERIALS AND REPLACE ALL DAMAGED MATERIAL WITH MATCHING

MATERIAL SIZE AND DIM. PREPARE FOR NEW FINISHES. NOTE CONTRACTOR TO

PROVIDE ALLOWANCE FOR DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING

BOARDS TO MATCH EXISTING ADJACENT, PER RESIDENCE IN BASE BID

DEMOLISH EXISTING CONCRETE WALK AND PATIO COMPLETE. SEE CIVIL

DRAWINGS FOR SCOPE OF WORK.

DEMO EXISTING DORMER SIDING AND ROOFING, FLASHING AND UNDERLAYMENT.

INSPECT SHEATHING FOR DAMAGE AND REMOVE ALL DAMAGED MATERIAL, AND

PREP WINDOW OPENING FOR NEW FRAMING. NOTE: SCHEDULE THIS WORK SO AS

TO REPLACE WITH NEW AT EACH LOCATION ONCE AREA IS REPAIRED, SO AS TO

MINIMIZE BREAKS IN THE BUILDING ENVELOPE. CONTRACTOR TO PROVIDE

ALLOWANCE FOR DEMO AND REPLACEMENT OF ALL WINDOW SILL FRAMING AND

(4) 8FT 1x8 WALL SHEATHING AND (4) 8FT FACIA AND TRIM BOARDS TO MATCH

EXISTING PER DORMER AND TYPICAL FOR EACH RESIDENCE ADDRESS IN BASE

BID.

DEMOLISH PORTION OF WALLS AS SHOWN, PROVIDE SHORING PRIOR TO

DEMOLITION AS REQUIRED. SHORING TO BE CONTINUOUS TO FOUNDATION

BELOW OR NEARBY ADJACENT LOADBEARING STRUCTURE, COORDINATE WITH

STRUCTURAL DRAWINGS.

EXISTING METAL CHIMNEY FLUE SCREEN/CAP TO BE REMOVED AND PREP FOR

NEW SCREEN/CAP.

REMOVE ALL EXISTING WINDOWS, CASEMENT AND TRIM INSPECT OPENING FOR

WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER TO

WINDOW SCHEDULES SHEET A603 FOR LOCATIONS REQUIRING REPLACEMENT OF

DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING COORDINATE WITH

STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT FRAMING AND

BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE WITH NEW AT EACH

LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE BREAKS IN THE

ENVELOPE.

NOTES 18- 24 ARE UNIT AND ADDRESS SPECIFIC REGARDING ABATEMENT

SEE SPEC TABLE 01 02 20 FOR ABETMENT QUANTITIES

ABATE ASSUMED ASBESTOS-CONTAINING VIBRATION DAMPER (733 PEARSON, 447

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASSUMED ASBESTOS-CONTAINING CERAMIC FLOOR TILE WITH

MORTAR/MASTIC AND GROUT (733 PEARSON, 419 JOHNSON, 447 JOHNSON, 523

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASSUMED ASBESTOS-CONTAINING CERAMIC WALL TILE WITH

MORTAR/MASTIC AND GROUT (733 PEARSON, 419 JOHNSON, 447 JOHNSON, 523

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASBESTOS-CONTAINING GRAY FLOOR LEVELER (733 PEARSON).

ABATE ASBESTOS-CONTAINING YELLOW MASTIC/FLOOR LEVELER (447 JOHNSON).

ABATE ASBESTOS-CONTAINING 12"X12" TAN FLOOR TILE WITH BLACK MASTIC (523

JOHNSON).

ABATE ASBESTOS-CONTAINING 9"X9" BLACK FLOOR TILE WITH NON-ASBESTOS-

CONTAINING BLACK MASTIC (420 METZGER).

DEMOLISH ALL LOOSE BRICK/ PAVER & STONEWORK & HANDRAIL SYSTEMS AT

FRONT PORCH AND STAIR AND PREP FOR REINSTALLATION SEE DEMO NOTE “O”

FOR FURTHER INFORMATION.

DEMOLISH EXISTING SHEATHING AT HIP CRICKET AT CHIMNEY/ ROOF AREA

COMPLETE TO MAIN ROOF AND ENTRY GABLE INTERSECTION. RE-FRAME NEW

VALLEY CRICKET. MAINTAIN EXISTING EAVE COORDINATE WITH STRUCTURAL FOR

FURTHER INFORMATION.

DEMOLISH ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT AND

FIXTURES COMPLETE, INCLUDING RADIATORS, BATHTUBS, SINKS, AND TOILETS

SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR FURTHER

INFORMATION.

EXISTING WINDOW WELL COVER / MOUNTING

HARDWARE AND FRAME TO BE REMOVED

COMPLETE. CONTRACTOR TO DOCUMENT

SIZE AND PROFILE FOR REPLACEMENT

COVER TO MATCH DEMOLISHED.

CLEAN ALL EXTERIOR FOUNDATION BASEMENT WALLS. STRIP INTERIOR FACE OF

ALL FINISHES TO EXPOSE CONCRETE. PREP SURFACE AND TREAT WITH

CEMENTITIOUS WATER-PROOFING. FINISHED BASEMENT AREAS INSTALL 2X

FURRING AND SHIM AS REQUIRED FOR STRAIGHT SMOOTH AND PLUMB SURFACE.

INSTALL 1/2" GWB SHEATHING AND

SCHEDULED FINISH AS INDICATED.

EXISTING TILE ROOF, UNDERLAYMENT, FLASHING, GUTTERS AND DOWNSPOUTS

TO BE REMOVED COMPLETE. CONTRACTOR TO INSPECT ALL EAVE AND GABLE

FASCIA, TRIM, AND ROOF SHEATHING AND REPLACE ALL DAMAGED MATERIAL TO

MATCH EXISTING ADJACENT; CONTRACTOR TO PROVIDE AN ALLOWANCE FOR

DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING BOARDS & (4) 8FT FACIA

AND TRIM BOARDS TO MATCH EXISTING TO BE REPLACED IN BASE BID NOTE: ALL

DECORATIVE STRAPS AND SCUPPER BOXES TO BE PROTECTED AND SALVAGED

FOR REINSTALLATION

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

AD102

S

T F

L O

O R

D E

M O

L

IT

IO

N

P L

A N

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

D A

Y T

O N

O

H

IO

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J W

IL

K

E R

S O

N

N B

E R

B E

R

IC

H

S D

E G

A R

O

R C

U R

R A

N

J A

N U

A R

Y

W Q

R -1

-F

-0

CERTIFIED FINAL FOR CONSTRUCTION

IM

P

R O

V E

F A

M

IL

Y H

O U

S

IN

G

P

F

IL

E N

U M

B E

R

TYPE G

1/4" = 1'-0"A2

1ST FLOOR DEMOLITION PLAN

0 2' 4' 8'

A m e n d m e n t

M

A R

C H

GENERAL NOTES:

KEYNOTES

LEGEND

KEYNOTES CONTINUED

03/10/21 W

2Q R

R

-0

CL

L4

BEDROOM 3

61 SF

BATH 2

HALL 2

BEDROOM 2

6 6

A

A

G G

G G

F

F

GG

A. DOCUMENT MOLDING TYPE AND LOCATION AND SALVAGE AND PROTECT A 24”

SECTION OF EACH TYPE, TYPICAL. RETAIN FOR SHPO.

B. DEMOLISH ALL EXISTING CABINETS, COUNTERTOPS, APPLIANCES, SINKS, AND

SHELVING THROUGHOUT.

C. DEMOLISH EXISTING CASEWORK AND BUILT-INS, DOCUMENT BUILT-INS PRIOR TO

DEMOLITION WITH PHOTO DOCUMENTATION ORGANIZED BY ADDRESS AND UNIT

TYPE, DIGITAL COPIES PROVIDED TO BASE HOUSING, ARCHITECT AND SHPO.

D. DEMOLISH ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT AND

FIXTURES COMPLETE, INCLUDING RADIATORS, BATHTUBS, SINKS, AND TOILETS

SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR FURTHER

INFORMATION.

E. DEMOLISH EXISTING PLASTER/ GYPSUM BOARD AND WALL FINISH, WALL BASE,

AND MOLDING ON ALL WALLS REQUIRING ELECTRICAL WORK AND ALL EXTERIOR

WALLS, DEMOLISH BATT INSULATION AT EXTERIOR WALLS.

F. DEMOLISH EXISTING FLOORING AND FASTENERS COMPLETE, CLEAN AND PREP

FOR NEW FINISHES.

G. DEMOLISH EXISTING CEILING COMPLETE INCLUDING INSULATION, DIFFUSERS,

RETURNS, AND LIGHTS.

H. REMOVE ALL EXISTING WINDOWS, CASEMENT AND TRIM INSPECT OPENING FOR

WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER TO

WINDOW SCHEDULES SHEET A601 FOR LOCATIONS REQUIRING REPLACEMENT

OF DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING COORDINATE WITH

STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT FRAMING AND

BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE WITH NEW AT EACH

LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE BREAKS IN THE

ENVELOPE.

I. REMOVE ALL BASEMENT WINDOWS, CASEMENT AND TRIM INSPECT OPENING

FOR WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER

TO WINDOW SCHEDULES SHEET A603 FOR LOCATIONS REQUIRING

REPLACEMENT OF DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING

COORDINATE WITH STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT

FRAMING AND BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE

WITH NEW AT EACH LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE

BREAKS IN THE ENVELOPE.

J. EXISTING TILE ROOF, UNDERLAYMENT, FLASHING, GUTTERS AND DOWNSPOUTS

TO BE REMOVED COMPLETE. CONTRACTOR TO INSPECT ALL EAVE AND GABLE

FASCIA, TRIM, AND ROOF SHEATHING AND REPLACE ALL DAMAGED MATERIAL TO

MATCH EXISTING ADJACENT; CONTRACTOR TO PROVIDE AN ALLOWANCE FOR

DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING BOARDS AND (8) EACH OF

8FT TRIM AND FASCIA BOARDS TO MATCH EXISTING ADJACENT CONSTRUCTION

PER BUILDING IN BASE BID NOTE: ALL DECORATIVE STRAPS AND SCUPPER

BOXES TO BE PROTECTED AND SALVAGED FOR REINSTALLATION.

K. EXISTING SCREENED IN PORCH ENCLOSURES TO BE DEMOLISHED COMPLETE.

REFER TO CIVIL FOR LOCATION AND QUANTITY OF SCREENED IN PORCHES TO

BE DEMOLISHED.

L. CONTRACTOR TO RETAIN UNDAMAGED BRICK FOR INFILLING OPERATIONS.

M. ALL METAL AND COPPER DEMOLISHED MUST GO TO RECYCLING CENTER,

COORDINATE BASE ENVIRONMENTAL OFFICE.

N. CONTRACTOR TO SALVAGE A 2’X2’ SECTION OF THE PLASTER WALL SYSTEM

COMPLETE AND RETAIN FOR SHPO.

O. REMOVE CLEAN AND PREP FOR RE-INSTALLATION ALL LOOSE BRICK/ PAVER &

STONEWORK. REMOVE ALL LOOSE AND SPRAWLING GROUT AND BASE @

EXISTING FRONT PORCH AND STAIR TO SOLID SUB STRUCTURE, PREP SURFACE

FOR REINSTALLATION STONEWORK TO MATCH EXISTING ADJACENT SURFACE

LEVEL. INSPECT HANDRAIL SYSTEM FOR LOOSE OR UNSTABLE CONDITIONS

REMOVE, STRIP OF FINISHES AND PREP FOR REINSTALLATION EXISTING LOOSE

OR UNSTABLE HANDRAIL SYSTEMS COMPLETE. CONTRACTOR TO MINIMIZE

DAMAGE TO SURROUNDING SURFACES TO REMAIN. AND PROVIDE ALLOWANCE

FOR 27 SF OF PORCH AND STAIR STONEWORK PER RESIDENCE ADDRESS TO BE

REMOVED AND REINSTALLED IN BASE BID. NOTE: CONTRACTOR TO PROVIDE

ALLOWANCE FOR REMOVAL AND REINSTALLATION OF ALL EXTERIOR HANDRAIL

SYSTEMS ON 10 RESIDENCES IN BASE BID. ALLOWANCE TO BE APPLIED

AS REQUIRED.

P. DEMOLISH METAL AWNINGS, FRAMES AND MOUNTING HARDWARE @ WINDOWS

AND FRONT PORCH COMPLETE. CONTRACTOR TO TUCKPOINT ALL

PENETRATIONS IN GROUT AND REPLACE ALL DAMAGED BRICK AT MOUNTING

LOCATIONS.

EXISTING WALL TO

REMAIN

EXISTING WALL TO BE

DEMOLISHED

EXISTING DOOR TO

REMAIN

EXISTING DOOR TO BE

DEMOLISHED

DEMOLISH PORTION OF WALL AS SHOWN, PROVIDE SHORING PRIOR TO

DEMOLITION AS REQUIRED. SHORING TO BE CONTINUOUS TO FOUNDATION

BELOW, COORDINATE WITH STRUCTURAL DRAWINGS.

DEMO PORTION OF WALL COMPLETE TO DIMENSION SHOWN.

DEMOLISH EXISTING INTERIOR STAIR HANDRAILS AND PICKETS, SALVAGE AND

PROTECT A 24” SECTION, RETAIN FOR SHPO.

DEMOLISH ALL EXISTING CABINETS, COUNTERTOPS, APPLIANCES, SINKS &

SHELVING & BUILT-INS THROUGHOUT, SEE DEMO NOTES A, B & C FOR FURTHER

INFORMATION.

DEMOLISH EXISTING HEARTH TILE AND MANTLE, TRIM, AND GAS LOGS, SALVAGE

GAS LOGS FOR REINSTALLATION, COORDINATE WITH MECHANICAL AND

ELECTRICAL FOR REWORK OF HOOKUPS.

DEMOLISH EXISTING DOOR AND HARDWARE COMPLETE.

DEMOLISH EXISTING WALL AS SHOWN.

REMOVE EXISTING DOOR, SALVAGE DOOR AND ALL HARDWARE FOR

REINSTALLATION. RE-FINISH AND REPAIR SALVAGED DOOR, RESTORE HARDWARE,

WEATHERSTRIPPING AND SWEEP AND REPLACE THE LOWER VERTICAL

(APPROX. 7 FT) OF HINGE AND LATCH JAMB BOARDS WITH NEW WOOD TO MATCH

EXISTING, MORTISE HINGES AND LATCH HARDWARE AS REQUIRED. PROVIDE 1

PRIMER AND 2 FINISH COATS OF PAINT. CONTRACTOR TO PROVIDE ALLOWANCE

FOR (2) 7' 2X6 JAMB BOARDS IN BASE BID, TO BE CUT TO FIT AS REQUIRED TO

MATCH EXISTING. FIELD MEASURE SIZE REQUIRED. SEE FINISH AND DOOR SCHED.

FOR MORE INFORMATION

DEMOLISH EXISTING STORM DOOR FRAME AND HARDWARE COMPLETE.

DEMOLISH EXISTING METAL WINDOW AWNING, FLASHING AND FRAMING AND

FASTENERS COMPLETE, SEE GENERAL NOTE “P” FOR FURTHER INFORMATION.

DEMOLISH EXISTING METAL FRONT PORCH ROOF, FLASHING AND FRAMING

COMPLETE, DEMO GUTTER AND DOWNSPOUT, PREP FOR NEW ROOF FRAMING,

COORDINATE WITH STRUCTURAL, SEE GENERAL NOTE “P” FOR FURTHER

INFORMATION.

DEMOLISH EXISTING PORCH COPPER ROOF AND FLASHING COMPLETE TO

SHEATHING, DEMO GUTTER AND DOWNSPOUT, INSPECT SHEATHING FOR

DAMAGED MATERIALS AND REPLACE ALL DAMAGED MATERIAL WITH MATCHING

MATERIAL SIZE AND DIM. PREPARE FOR NEW FINISHES. NOTE CONTRACTOR TO

PROVIDE ALLOWANCE FOR DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING

BOARDS TO MATCH EXISTING ADJACENT, PER RESIDENCE IN BASE BID

DEMOLISH EXISTING CONCRETE WALK AND PATIO COMPLETE. SEE CIVIL

DRAWINGS FOR SCOPE OF WORK.

DEMO EXISTING DORMER SIDING AND ROOFING, FLASHING AND UNDERLAYMENT.

INSPECT SHEATHING FOR DAMAGE AND REMOVE ALL DAMAGED MATERIAL, AND

PREP WINDOW OPENING FOR NEW FRAMING. NOTE: SCHEDULE THIS WORK SO AS

TO REPLACE WITH NEW AT EACH LOCATION ONCE AREA IS REPAIRED, SO AS TO

MINIMIZE BREAKS IN THE BUILDING ENVELOPE. CONTRACTOR TO PROVIDE

ALLOWANCE FOR DEMO AND REPLACEMENT OF ALL WINDOW SILL FRAMING AND

(4) 8FT 1x8 WALL SHEATHING AND (4) 8FT FACIA AND TRIM BOARDS TO MATCH

EXISTING PER DORMER AND TYPICAL FOR EACH RESIDENCE ADDRESS IN BASE

BID.

DEMOLISH PORTION OF WALLS AS SHOWN, PROVIDE SHORING PRIOR TO

DEMOLITION AS REQUIRED. SHORING TO BE CONTINUOUS TO FOUNDATION

BELOW OR NEARBY ADJACENT LOADBEARING STRUCTURE, COORDINATE WITH

STRUCTURAL DRAWINGS.

EXISTING METAL CHIMNEY FLUE SCREEN/CAP TO BE REMOVED AND PREP FOR

NEW SCREEN/CAP.

REMOVE ALL EXISTING WINDOWS, CASEMENT AND TRIM INSPECT OPENING FOR

WATER/ MOLD/ INSECT DAMAGE, REMOVE ALL DAMAGED MATERIAL REFER TO

WINDOW SCHEDULES SHEET A603 FOR LOCATIONS REQUIRING REPLACEMENT OF

DAMAGED MASONRY LINTELS, SILLS AND TUCK POINTING COORDINATE WITH

STRUCTURAL . PREP OPENING TO RECEIVE REPLACEMENT FRAMING AND

BLOCKING. NOTE: SCHEDULE THIS WORK SO AS TO REPLACE WITH NEW AT EACH

LOCATION ONCE OPENING IS REPAIRED SO AS TO MINIMIZE BREAKS IN THE

ENVELOPE.

NOTES 18- 24 ARE UNIT AND ADDRESS SPECIFIC REGARDING ABATEMENT

SEE SPEC TABLE 01 02 20 FOR ABETMENT QUANTITIES

ABATE ASSUMED ASBESTOS-CONTAINING VIBRATION DAMPER (733 PEARSON, 447

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASSUMED ASBESTOS-CONTAINING CERAMIC FLOOR TILE WITH

MORTAR/MASTIC AND GROUT (733 PEARSON, 419 JOHNSON, 447 JOHNSON, 523

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASSUMED ASBESTOS-CONTAINING CERAMIC WALL TILE WITH

MORTAR/MASTIC AND GROUT (733 PEARSON, 419 JOHNSON, 447 JOHNSON, 523

JOHNSON, 420 METZGER, 448 METZGER, 524 METZGER).

ABATE ASBESTOS-CONTAINING GRAY FLOOR LEVELER (733 PEARSON).

ABATE ASBESTOS-CONTAINING YELLOW MASTIC/FLOOR LEVELER (447 JOHNSON).

ABATE ASBESTOS-CONTAINING 12"X12" TAN FLOOR TILE WITH BLACK MASTIC (523

JOHNSON).

ABATE ASBESTOS-CONTAINING 9"X9" BLACK FLOOR TILE WITH NON-ASBESTOS-

CONTAINING BLACK MASTIC (420 METZGER).

DEMOLISH ALL LOOSE BRICK/ PAVER & STONEWORK & HANDRAIL SYSTEMS AT

FRONT PORCH AND STAIR AND PREP FOR REINSTALLATION SEE DEMO NOTE “O”

FOR FURTHER INFORMATION.

DEMOLISH EXISTING SHEATHING AT HIP CRICKET AT CHIMNEY/ ROOF AREA

COMPLETE TO MAIN ROOF AND ENTRY GABLE INTERSECTION. RE-FRAME NEW

VALLEY CRICKET. MAINTAIN EXISTING EAVE COORDINATE WITH STRUCTURAL FOR

FURTHER INFORMATION.

DEMOLISH ALL PLUMBING, MECHANICAL AND ELECTRICAL EQUIPMENT AND

FIXTURES COMPLETE, INCLUDING RADIATORS, BATHTUBS, SINKS, AND TOILETS

SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR FURTHER

INFORMATION.

EXISTING WINDOW WELL COVER / MOUNTING

HARDWARE AND FRAME TO BE REMOVED

COMPLETE. CONTRACTOR TO DOCUMENT

SIZE AND PROFILE FOR REPLACEMENT

COVER TO MATCH DEMOLISHED.

CLEAN ALL EXTERIOR FOUNDATION BASEMENT WALLS. STRIP INTERIOR FACE OF

ALL FINISHES TO EXPOSE CONCRETE. PREP SURFACE AND TREAT WITH

CEMENTITIOUS WATER-PROOFING. FINISHED BASEMENT AREAS INSTALL 2X

FURRING AND SHIM AS REQUIRED FOR STRAIGHT SMOOTH AND PLUMB SURFACE.

INSTALL 1/2" GWB SHEATHING AND

SCHEDULED FINISH AS INDICATED.

EXISTING TILE ROOF, UNDERLAYMENT, FLASHING, GUTTERS AND DOWNSPOUTS

TO BE REMOVED COMPLETE. CONTRACTOR TO INSPECT ALL EAVE AND GABLE

FASCIA, TRIM, AND ROOF SHEATHING AND REPLACE ALL DAMAGED MATERIAL TO

MATCH EXISTING ADJACENT; CONTRACTOR TO PROVIDE AN ALLOWANCE FOR

DEMO AND REPLACEMENT OF (8) 8FT 1X8 SHEATHING BOARDS & (4) 8FT FACIA

AND TRIM BOARDS TO MATCH EXISTING TO BE REPLACED IN BASE BID NOTE: ALL

DECORATIVE STRAPS AND SCUPPER BOXES TO BE PROTECTED AND SALVAGED

FOR REINSTALLATION

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

AD103

N

D F

L O

O R

D E

M O

L

IT

IO

N

P L

A N

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

D A

Y T

O N

O

H

IO

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J W

IL

K

E R

S O

N

N B

E R

B E

R

IC

H

S D

E G

A R

O

R C

U R

R A

N

J A

N U

A R

Y

W Q

R -1

-F

-0

CERTIFIED FINAL FOR CONSTRUCTION

IM

P

R O

V E

F A

M

IL

Y H

O U

S

IN

G

P

F

IL

E N

U M

B E

R

TYPE G

1/4" = 1'-0"A2

2ND FLOOR DEMOLITION PLAN

0 2' 4' 8'

A m e n d m e n t

M

A R

C H

GENERAL NOTES:

KEYNOTES

LEGEND

KEYNOTES CONTINUED

03/10/21 W

2Q R

R

-0

D2

A-301

A2

A-301

A1 A-202

D1 A-201

D1 A-202

A1

A-201STORAGE

MECH RM

LAUNDRY

CRAWL SPACE

H

H

A-401

A3

002B

A8

A-302

AD002

CRAWL SPACE

NIC

NIC

001A

AD001

EMERGENCY ESCAPE

OPENING

EMERGENCY

ESCAPE

OPENING

002A

LOUVER

A-601

A. REFER TO INTERIOR DRAWINGS FOR FINISH SCHEDULE.

B. REFER TO INTERIOR DRAWINGS FOR CABINET AND COUNTER FINISHES.

C. ALL NEW INTERIOR WALLS TO BE 2"X4" STUDS@ 16” O.C. TYPICAL WALLS

WITH 1/2" GYPSUM BOARD BOTH SIDES UNLESS NOTED OTHERWISE. SEE

WALL LEGEND

D. FIELD VERIFY ALL DIMENSIONS.

E. REFER TO ABBREVIATION LIST FOR DEFINITION OF ABBREVIATIONS. WHEN

AN ABBREVIATION IS USED BUT NOT LISTED, THE DEFINITION IN THE

SPECIFICATIONS OR REQUEST FOR PROPOSAL (RFP) SHOULD BE USED.

IN THE EVENT THAT AN ABBREVIATION IS NOT LISTED IN THE

SPECIFICATIONS OR RFP, THE INDUSTRY STANDARD DEFINITION

APPLICABLE TO THE CONTEXT SHOULD BE USED.

F. DIMENSIONS SHOWN ARE FACE TO FACE OF STUD, FACE OF CMU, FACE OF

CONCRETE OR GRID LINES (TYPICAL) UNLESS NOTED OTHERWISE.

DIMENSIONS WITH AN * SUFFIX ARE DIMENSIONED TO FACE OF EXTERIOR

WALL ASSEMBLIES.

G. DIMENSIONS MARKED AS "CLEAR" INDICATES THE DIMENSION IS FROM

FINISH TO FINISH.

H. ALL SPOT ELEVATIONS ARE ABOVE FINISHED FLOOR.

I. CONTRACTOR SHALL PREPARE ALL WALLS AND PARTITIONS AS

RECOMMENDED BY THE FINISH MANUFACTURER TO RECEIVE THE FINISHES

SPECIFIED.

J. PROVIDE SOLID BLOCKING IN LOCATIONS WHERE CABINETS ARE

SCHEDULED

K. PROVIDE SOLID IN WALL BLOCKING IN LOCATIONS SCHEDULED FOR ADA

GRAB BARS AND ALL FUTURE PLANNED ADA GRAB BAR LOCATIONS

L. ACCESSIBLE ATTIC SPACES WHERE INDICATED WILL RECEIVE, UNFINISHED

AND UN-TAPED DRYWALL ON VERTICAL FRAMING ONLY. NO FINISHES WILL

BE PROVIDED ON ROOF FRAMING.

M. ALL EXISTING AND NEW EXTERIOR WOOD, TRIM, FASCIA, SIDING, PANELING,

DRESSED LUMBER AND STUCCO TO BE CLEANED AND PREPARED TO

RECEIVE NEW PAINT OR FINISH AS OTHERWISE NOTED. CONTRACTOR TO

PROVIDE (1) PRIMER COAT & (2) FINISH COATS. SEE SPECIFICATIONS FOR

FURTHER INFORMATION REGARDING PREPARATION AND FINISH

REQUIREMENTS.

.N. CONTRACTOR TO PROVIDE FLOOR BASE, CHAIR RAIL AND PICTURE/CROWN

MOLD, PROFILE AND SIZE TO MATCH HISTORIC SALVAGED TRIM. ALL

FOYER/LIVING/FAMILY/DINING/SITTING ROOMS ON THE FIRST FLOOR TO

RECEIVE CHAIR RAIL AND ALL ROOMS TO RECEIVE FLOOR

BASE/CROWN/PICTURE MOLD ON FIRST AND SECOND FLOOR LIVING

SPACES SEE DETAIL SHEET A-503.

PAINTED WOOD CASED OPENING, TRIM PROFILE AND SIZE TO MATCH

SALVAGED HISTORIC TRIM.

NEW HANDRAIL AND PICKETS, SEE DETAIL A5/A-504.

NEW FIREPLACE INSERT AND GAS LOGS COORDINATE WITH MECHANICAL AND

ELECTRICAL DRAWINGS, SEE MANTEL DETAILS AND COORDINATE WITH

INTERIORS FOR SCHEDULED FINISHES.

NEW DOOR AND HARDWARE SEE DOOR SCHEDULE AND DETAILS.

REMOVE EXISTING DOOR, SALVAGE DOOR AND ALL HARDWARE FOR

REINSTALLATION. RE-FINISH AND REPAIR SALVAGED DOOR, RESTORE

HARDWARE, WEATHERSTRIPPING AND SWEEP AND REPLACE THE LOWER

VERTICAL (APPROX. 7 FT) OF HINGE AND LATCH JAMB BOARDS WITH NEW

WOOD TO MATCH EXISTING, MORTISE HINGES AND LATCH HARDWARE AS

REQUIRED. PROVIDE 1 PRIMER AND 2 FINISH COATS OF PAINT. CONTRACTOR

TO PROVIDE ALLOWANCE FOR (2) 7' 2X6 JAMB BOARDS IN BASE BID, TO BE

CUT TO FIT AS REQUIRED TO MATCH EXISTING. FIELD MEASURE SIZE

REQUIRED. SEE FINISH AND DOOR SCHED. FOR MORE INFORMATION

2’-0”X2’-0” FRAMED ACCESS PAINTED ¾” THICK SOLID WOOD PANEL LOCATE IN

EXISTING JOIST FRAMING, PROVIDE BLOCKING AS REQUIRED, MATCH EXISTING

JOIST MEMBER SIZE. PICTURE FRAME OPENING WITH CASING TO MATCH

DOOR CASING, PAINT TO MATCH TRIM.

PROVIDE AND INSTALL NEW FLUID-APPLIED AIR BARRIER MEMBRANE OVER

1/2" DRAINAGE MATT ON CAVITY SIDE OF ALL EXTERIOR WALLS AND PROVIDE

AND INSTALL NEW INSULATION AT ALL EXTERIOR WALLS

EXTERIOR FACE OF MASONRY WALLS TO BE CLEANED AND PREPARED FOR

COMPLETION OF TUCKPOINTING SCOPE. REFER TO SPECIFICATIONS FOR

REQUIREMENTS AND FURTHER INFORMATION. NOTE CONTRACTOR TO

PROVIDE ALLOWANCE FOR 970 SF OF TUCKPOINTING PER BUILDING IN THE

BASE BID.

NEW STANDING SEAM METAL ROOF OVER NEW FRONT PORCH ROOF

FRAMING, SEE ENLARGED DETAILS, ROOF PLAN AND STRUCTURAL DRAWINGS

FOR FURTHER INFORMATION.

NEW TILE ROOF, SEE ENLARGED DETAILS, ROOF PLAN & DETAILS FOR

FURTHER INFORMATION. TILE WEIGHT MUST NOT EXCEED EXISTING TILE

WEIGHT.

NEW 6" K-STYLE GUTTER, WITH FACTORY END CAPS AND CORNERS, AND 3"X4"

DOWNSPOUT TO MATCH EXISTING, COLOR TO BE PREFINISHED DARK BRONZE.

USE SALVAGED SCUPPERS AND STRAPS, REPLACE TO ORIGINAL LOCATIONS

PROVIDE SPLASHBLOCKS AT EACH LOCATION TYPICAL.

NEW WINDOW, CASEMENT AND TRIM, PAINT TRIM TO MATCH EXISTING

ADJACENT SEE DETAILS AND SCHEDULE FOR FURTHER INFORMATION.

REINSTALL SALVAGED & CLEANED STONEWORK @ EXISTING FRONT PORCH

AND STAIR TO MATCH EXISTING ADJACENT SURFACE LEVEL. REINSTALLED

HANDRAILS WILL BE SET IN EPOXY GROUT WITH A MINIMUM DEVELOPMENT

LENGTH OF 6" BELOW THE STONE PAVERS. PROVIDE (1) PRIMER COAT AND (2)

FINISH COATS OF PAINT (COLOR: BLACK, FINISH: SATIN.

INSTALL NEW DORMER STANDING SEAM METAL ROOF AND FLASHING, NEW 6"

K-STYLE GUTTER, WITH FACTORY END CAPS AND CORNERS, AND 3"X4"

DOWNSPOUT

PROVIDE ICE AND SNOW GUARDS ON ALL ROOFS, SEE DETAILS D1 & D6 &B1/

A-506 FOR LAYOUT AND SPECIFICATIONS FOR FURTHER INFORMATION.

NEW STORM DOOR FRAME AND HARDWARE SEE SCHEDULE FOR FURTHER

INFORMATION.

REPLACE DAMAGED TRIM AND FASCIA BOARDS AND PAINT TO MATCH

EXISTING, NOTE CONTRACTOR TO PROVIDE ALLOWANCE FOR 30 LBF /

ADDRESS OF NON-WINDOW TRIM AND FASCIA BOARDS TO BE REPLACED IN

BASE BID TYP.

PROVIDE NEW ¾” T&G PLYWOOD SUBFLOOR OVER EXISTING FLOOR JOISTS,

GLUE AND SCREW FASTENER SPACING 16” MAX @ EACH JOIST TYPICAL, SEE

STRUCTURAL FOR FURTHER INFORMATION.

PROVIDE NEW VINYL-COATED WIRE SHELVES WITH ROD AS SHOWN, ALL

CLOSETS HAVE DOUBLE STACKED SHELVES, ALL LINEN CLOSETS TO RECEIVE

3 SHELVES, ALL PANTRIES TO RECEIVE 4 SHELVES IN CONFIGURATION

SHOWN, SEE PLAN.

EXISTING CRAWL SPACE TO BE GRADED, PROVIDE A 10 MIL POLY VAPOR

BARRIER CONTINUOUS RETURN VAPOR BARRIER TO TOP OF FOUNDATION

WALL AND FASTEN TO SILL PLATE TYPICAL, TAPE ALL SEAMS. PROVIDE R-21

RIGID INSULATION @ ALL PERIMETER FOUNDATION WALLS.

2X6 INTERIOR WALL PARTITION SEE WALL LEGEND, TYPICAL INTERIOR WALL

PARTITION FOR FURTHER INFORMATION.

NEW INSULATED PAINTED METAL ACCESS DOOR, PROVIDE NEW FRAME &

MANUFACTURER PROVIDED HARDWARE. ACCESS DOOR TO CRAWL SPACES

FROM THE INTERIOR NEED TO HAVE WEATHERSTRIPPING.

WALL TO BE REPAIRED/INFILLED AND PATCHED TO MATCH ADJACENT

EXISTING CONSTRUCTION. PREPARE SURFACE FOR WALL FINISH.

WOOD PLANTATION SHUTTERS, PAINT TO MATCH TRIM TYPICAL ALL WINDOW

LOCATIONS EXCEPT BASEMENT. SEE DETAIL A6/A-501 FOR TREATMENT AT

WINDOW SHOWER LOCATIONS, ALL OTHER LOCATIONS OMIT GLASS PANEL

AND MAGNETIC CLOSURE SYSTEM.

INSTALL NEW VALLEY CRICKET OVER BATH 2 ROOM 202. SEE ROOF DETAIL

AND COORDINATE WITH STRUCTURAL FOR FURTHER INFORMATION.

INSTALL NEW WINDOW WELL COVER. PROFILE AND FRAME TO MATCH

ORIGINAL COVER.

CLEAN ALL EXTERIOR FOUNDATION BASEMENT WALLS. STRIP INTERIOR FACE

OF ALL FINISHES TO EXPOSE CONCRETE. PREP SURFACE AND TREAT

WITH CEMENTITIOUS WATERPROOFING. FINISHED BASEMENT AREAS

(LAUNDRY), INSTALL 2X FURRING AND SHIM AS REQUIRED FOR STRAIGHT

SMOOTH & PLUMB SURFACE. INSTALL ½” GWB SHEATHING AND SCHEDULED

FINISH AS INDICATED.

MAINTENANCE HOLD OFF. SEE DETAIL

C7 ON SHEET A-201.

EXISTING STUCCO AND TIMBER TO BE

REPAIRED / REPLACED AS REQUIRED,

CONTRACTOR TO ALLOW FOR 100 SF

OF THE STUCCO TO BE REMOVED AND

REINSTALLED, AND (8) 8FT SECTIONS OF

TRIM BOARDS AND CORRELATING FLASHING

TO BE REMOVED AND

REPLACED WITH NEW

FLASHING AND REDWOOD

TRIM BOARDS SIZE AND

INSTALLATION TO MATCH

EXISTING IN

THE BASE BID.

NEW DORMER SIDING AS REQUIRED BY

DEMO SCOPE OF WORK. SEE DEMO

KEYNOTE 14. NOTE: SCHEDULE THIS

WORK SO AS TO REPLACE WITH NEW

AT EACH LOCATION ONCE AREA IS

REPAIRED, SO AS TO MINIMIZE BREAKS

IN THE BUILDING ENVELOPE.

NOTE CONTRACTOR TO

PROVIDE ALLOWANCE

FOR (8) 8ft 1x8 WALL SHEATHING

BOARDS / ADDRESS OF SHEATHING TO

BE REPLACED IN BASE BID TYP.

OPENING

POCKET DOOR

INTERIOR DOOR

EXTERIOR DOUBLE

PANEL DOOR

EXTERIOR SINGLE

PANEL DOOR

DOUBLE HUNG WINDOW

CASEMENT WINDOW

NEW WALL

CONSTRUCTION

EXISTING WALL

CONSTRUCTION

1 HR DUPLEX

PARTY WALL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

A-101

B A

S E

M E

N T

P L

A N

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

D A

Y T

O N

O

H

IO

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J W

IL

K

E R

S O

N

N B

E R

B E

R

IC

H

S D

E G

A R

O

R C

U R

R A

N

J A

N U

A R

Y

W Q

R -1

-F

-0

CERTIFIED FINAL FOR CONSTRUCTION

IM

P

R O

V E

F A

M

IL

Y H

O U

S

IN

G

P

F

IL

E N

U M

B E

R

TYPE G

GENERAL NOTES: KEYNOTES

1/4" = 1'-0"A2

BASEMENT PLAN

0 2' 4' 8'

LEGEND

• ALL TYPICAL INTERIOR WALLS MAY BE FRAMED WITH WOOD OR EQUALLY SIZED

METAL STUDS AT A MAX OF 16" O.C. TYP. SEE STRUCTURAL SPECIFICATIONS

FOR ADDITIONAL REQUIREMENTS UNLESS OTHERWISE NOTED, WITH (1) LAYER

½” GYPSUM BOARD EACH SIDE. (PROVIDE GREEN BOARD @ ALL WET

LOCATIONS, PROVIDE CONCRETE BOARD AT ALL TILE LOCATIONS.) SEE

INTERIOR DRAWINGS FOR SCHEDULED FINISHES.

WALL LEGEND

A m e n d m e n t

M

A R

C H

1 1

1 1

03/10/21 W

2Q R

R

-0

DN

DW

R E

F

D2

A-301

A2

A-301

A1 A-202

D1 A-201

D1 A-202

A1 A-201

BEDROOM 1

LIVING RM

FOYER

BATH 3

BATH 1

DINING

CLOSET

HALL CLOSET

101 A

LIN

108A

LIN

106 A

HALL

FAMILY

KITCHEN

AA

B

B

B

B

B B B

C

C C C B B

A

A

D

EF EE

8 8

12 7 7

100A

106B

108B

108A

109A 101C

107A

101A

101B

106A

A-401

D4

A1

A-302

A4

A-302

A8

A-302

A7

A-303

A4

A-303

A6

A-302

A-401

D1

19 19

EGRESS WINDOW

EGRESS

DOOR

EGRESS

DOOR

NOTE: “GFCI” SHOWING GOVT. FURNISHED,

CONTRACTOR INSTALLED EQUIPMENT (OVEN,

MICROWAVE, REFRIGERATOR, DISHWASHER)

GFCI GFCI

GFCI

GFCI

UNDER

CABINET

MICROWAVE

S101A

S100A

1' - 3"

11 11

11 11

A-601

A. REFER TO INTERIOR DRAWINGS FOR FINISH SCHEDULE.

B. REFER TO INTERIOR DRAWINGS FOR CABINET AND COUNTER FINISHES.

C. ALL NEW INTERIOR WALLS TO BE 2"X4" STUDS@ 16” O.C. TYPICAL WALLS

WITH 1/2" GYPSUM BOARD BOTH SIDES UNLESS NOTED OTHERWISE. SEE

WALL LEGEND

D. FIELD VERIFY ALL DIMENSIONS.

E. REFER TO ABBREVIATION LIST FOR DEFINITION OF ABBREVIATIONS. WHEN

AN ABBREVIATION IS USED BUT NOT LISTED, THE DEFINITION IN THE

SPECIFICATIONS OR REQUEST FOR PROPOSAL (RFP) SHOULD BE USED.

IN THE EVENT THAT AN ABBREVIATION IS NOT LISTED IN THE

SPECIFICATIONS OR RFP, THE INDUSTRY STANDARD DEFINITION

APPLICABLE TO THE CONTEXT SHOULD BE USED.

F. DIMENSIONS SHOWN ARE FACE TO FACE OF STUD, FACE OF CMU, FACE OF

CONCRETE OR GRID LINES (TYPICAL) UNLESS NOTED OTHERWISE.

DIMENSIONS WITH AN * SUFFIX ARE DIMENSIONED TO FACE OF EXTERIOR

WALL ASSEMBLIES.

G. DIMENSIONS MARKED AS "CLEAR" INDICATES THE DIMENSION IS FROM

FINISH TO FINISH.

H. ALL SPOT ELEVATIONS ARE ABOVE FINISHED FLOOR.

I. CONTRACTOR SHALL PREPARE ALL WALLS AND PARTITIONS AS

RECOMMENDED BY THE FINISH MANUFACTURER TO RECEIVE THE FINISHES

SPECIFIED.

J. PROVIDE SOLID BLOCKING IN LOCATIONS WHERE CABINETS ARE

SCHEDULED

K. PROVIDE SOLID IN WALL BLOCKING IN LOCATIONS SCHEDULED FOR ADA

GRAB BARS AND ALL FUTURE PLANNED ADA GRAB BAR LOCATIONS

L. ACCESSIBLE ATTIC SPACES WHERE INDICATED WILL RECEIVE, UNFINISHED

AND UN-TAPED DRYWALL ON VERTICAL FRAMING ONLY. NO FINISHES WILL

BE PROVIDED ON ROOF FRAMING.

M. ALL EXISTING AND NEW EXTERIOR WOOD, TRIM, FASCIA, SIDING, PANELING,

DRESSED LUMBER AND STUCCO TO BE CLEANED AND PREPARED TO

RECEIVE NEW PAINT OR FINISH AS OTHERWISE NOTED. CONTRACTOR TO

PROVIDE (1) PRIMER COAT & (2) FINISH COATS. SEE SPECIFICATIONS FOR

FURTHER INFORMATION REGARDING PREPARATION AND FINISH

REQUIREMENTS.

.N. CONTRACTOR TO PROVIDE FLOOR BASE, CHAIR RAIL AND PICTURE/CROWN

MOLD, PROFILE AND SIZE TO MATCH HISTORIC SALVAGED TRIM. ALL

FOYER/LIVING/FAMILY/DINING/SITTING ROOMS ON THE FIRST FLOOR TO

RECEIVE CHAIR RAIL AND ALL ROOMS TO RECEIVE FLOOR

BASE/CROWN/PICTURE MOLD ON FIRST AND SECOND FLOOR LIVING

SPACES SEE DETAIL SHEET A-503.

PAINTED WOOD CASED OPENING, TRIM PROFILE AND SIZE TO MATCH

SALVAGED HISTORIC TRIM.

NEW HANDRAIL AND PICKETS, SEE DETAIL A5/A-504.

NEW FIREPLACE INSERT AND GAS LOGS COORDINATE WITH MECHANICAL AND

ELECTRICAL DRAWINGS, SEE MANTEL DETAILS AND COORDINATE WITH

INTERIORS FOR SCHEDULED FINISHES.

NEW DOOR AND HARDWARE SEE DOOR SCHEDULE AND DETAILS.

REMOVE EXISTING DOOR, SALVAGE DOOR AND ALL HARDWARE FOR

REINSTALLATION. RE-FINISH AND REPAIR SALVAGED DOOR, RESTORE

HARDWARE, WEATHERSTRIPPING AND SWEEP AND REPLACE THE LOWER

VERTICAL (APPROX. 7 FT) OF HINGE AND LATCH JAMB BOARDS WITH NEW

WOOD TO MATCH EXISTING, MORTISE HINGES AND LATCH HARDWARE AS

REQUIRED. PROVIDE 1 PRIMER AND 2 FINISH COATS OF PAINT. CONTRACTOR

TO PROVIDE ALLOWANCE FOR (2) 7' 2X6 JAMB BOARDS IN BASE BID, TO BE

CUT TO FIT AS REQUIRED TO MATCH EXISTING. FIELD MEASURE SIZE

REQUIRED. SEE FINISH AND DOOR SCHED. FOR MORE INFORMATION

2’-0”X2’-0” FRAMED ACCESS PAINTED ¾” THICK SOLID WOOD PANEL LOCATE IN

EXISTING JOIST FRAMING, PROVIDE BLOCKING AS REQUIRED, MATCH EXISTING

JOIST MEMBER SIZE. PICTURE FRAME OPENING WITH CASING TO MATCH

DOOR CASING, PAINT TO MATCH TRIM.

PROVIDE AND INSTALL NEW FLUID-APPLIED AIR BARRIER MEMBRANE OVER

1/2" DRAINAGE MATT ON CAVITY SIDE OF ALL EXTERIOR WALLS AND PROVIDE

AND INSTALL NEW INSULATION AT ALL EXTERIOR WALLS

EXTERIOR FACE OF MASONRY WALLS TO BE CLEANED AND PREPARED FOR

COMPLETION OF TUCKPOINTING SCOPE. REFER TO SPECIFICATIONS FOR

REQUIREMENTS AND FURTHER INFORMATION. NOTE CONTRACTOR TO

PROVIDE ALLOWANCE FOR 970 SF OF TUCKPOINTING PER BUILDING IN THE

BASE BID.

NEW STANDING SEAM METAL ROOF OVER NEW FRONT PORCH ROOF

FRAMING, SEE ENLARGED DETAILS, ROOF PLAN AND STRUCTURAL DRAWINGS

FOR FURTHER INFORMATION.

NEW TILE ROOF, SEE ENLARGED DETAILS, ROOF PLAN & DETAILS FOR

FURTHER INFORMATION. TILE WEIGHT MUST NOT EXCEED EXISTING TILE

WEIGHT.

NEW 6" K-STYLE GUTTER, WITH FACTORY END CAPS AND CORNERS, AND 3"X4"

DOWNSPOUT TO MATCH EXISTING, COLOR TO BE PREFINISHED DARK BRONZE.

USE SALVAGED SCUPPERS AND STRAPS, REPLACE TO ORIGINAL LOCATIONS

PROVIDE SPLASHBLOCKS AT EACH LOCATION TYPICAL.

NEW WINDOW, CASEMENT AND TRIM, PAINT TRIM TO MATCH EXISTING

ADJACENT SEE DETAILS AND SCHEDULE FOR FURTHER INFORMATION.

REINSTALL SALVAGED & CLEANED STONEWORK @ EXISTING FRONT PORCH

AND STAIR TO MATCH EXISTING ADJACENT SURFACE LEVEL. REINSTALLED

HANDRAILS WILL BE SET IN EPOXY GROUT WITH A MINIMUM DEVELOPMENT

LENGTH OF 6" BELOW THE STONE PAVERS. PROVIDE (1) PRIMER COAT AND (2)

FINISH COATS OF PAINT (COLOR: BLACK, FINISH: SATIN.

INSTALL NEW DORMER STANDING SEAM METAL ROOF AND FLASHING, NEW 6"

K-STYLE GUTTER, WITH FACTORY END CAPS AND CORNERS, AND 3"X4"

DOWNSPOUT

PROVIDE ICE AND SNOW GUARDS ON ALL ROOFS, SEE DETAILS D1 & D6 &B1/

A-506 FOR LAYOUT AND SPECIFICATIONS FOR FURTHER INFORMATION.

NEW STORM DOOR FRAME AND HARDWARE SEE SCHEDULE FOR FURTHER

INFORMATION.

REPLACE DAMAGED TRIM AND FASCIA BOARDS AND PAINT TO MATCH

EXISTING, NOTE CONTRACTOR TO PROVIDE ALLOWANCE FOR 30 LBF /

ADDRESS OF NON-WINDOW TRIM AND FASCIA BOARDS TO BE REPLACED IN

BASE BID TYP.

PROVIDE NEW ¾” T&G PLYWOOD SUBFLOOR OVER EXISTING FLOOR JOISTS,

GLUE AND SCREW FASTENER SPACING 16” MAX @ EACH JOIST TYPICAL, SEE

STRUCTURAL FOR FURTHER INFORMATION.

PROVIDE NEW VINYL-COATED WIRE SHELVES WITH ROD AS SHOWN, ALL

CLOSETS HAVE DOUBLE STACKED SHELVES, ALL LINEN CLOSETS TO RECEIVE

3 SHELVES, ALL PANTRIES TO RECEIVE 4 SHELVES IN CONFIGURATION

SHOWN, SEE PLAN.

EXISTING CRAWL SPACE TO BE GRADED, PROVIDE A 10 MIL POLY VAPOR

BARRIER CONTINUOUS RETURN VAPOR BARRIER TO TOP OF FOUNDATION

WALL AND FASTEN TO SILL PLATE TYPICAL, TAPE ALL SEAMS. PROVIDE R-21

RIGID INSULATION @ ALL PERIMETER FOUNDATION WALLS.

2X6 INTERIOR WALL PARTITION SEE WALL LEGEND, TYPICAL INTERIOR WALL

PARTITION FOR FURTHER INFORMATION.

NEW INSULATED PAINTED METAL ACCESS DOOR, PROVIDE NEW FRAME &

MANUFACTURER PROVIDED HARDWARE. ACCESS DOOR TO CRAWL SPACES

FROM THE INTERIOR NEED TO HAVE WEATHERSTRIPPING.

WALL TO BE REPAIRED/INFILLED AND PATCHED TO MATCH ADJACENT

EXISTING CONSTRUCTION. PREPARE SURFACE FOR WALL FINISH.

WOOD PLANTATION SHUTTERS, PAINT TO MATCH TRIM TYPICAL ALL WINDOW

LOCATIONS EXCEPT BASEMENT. SEE DETAIL A6/A-501 FOR TREATMENT AT

WINDOW SHOWER LOCATIONS, ALL OTHER LOCATIONS OMIT GLASS PANEL

AND MAGNETIC CLOSURE SYSTEM.

INSTALL NEW VALLEY CRICKET OVER BATH 2 ROOM 202. SEE ROOF DETAIL

AND COORDINATE WITH STRUCTURAL FOR FURTHER INFORMATION.

INSTALL NEW WINDOW WELL COVER. PROFILE AND FRAME TO MATCH

ORIGINAL COVER.

CLEAN ALL EXTERIOR FOUNDATION BASEMENT WALLS. STRIP INTERIOR FACE

OF ALL FINISHES TO EXPOSE CONCRETE. PREP SURFACE AND TREAT

WITH CEMENTITIOUS WATERPROOFING. FINISHED BASEMENT AREAS

(LAUNDRY), INSTALL 2X FURRING AND SHIM AS REQUIRED FOR STRAIGHT

SMOOTH & PLUMB SURFACE. INSTALL ½” GWB SHEATHING AND SCHEDULED

FINISH AS INDICATED.

MAINTENANCE HOLD OFF. SEE DETAIL

C7 ON SHEET A-201.

EXISTING STUCCO AND TIMBER TO BE

REPAIRED / REPLACED AS REQUIRED,

CONTRACTOR TO ALLOW FOR 100 SF

OF THE STUCCO TO BE REMOVED AND

REINSTALLED, AND (8) 8FT SECTIONS OF

TRIM BOARDS AND CORRELATING FLASHING

TO BE REMOVED AND

REPLACED WITH NEW

FLASHING AND REDWOOD

TRIM BOARDS SIZE AND

INSTALLATION TO MATCH

EXISTING IN

THE BASE BID.

NEW DORMER SIDING AS REQUIRED BY

DEMO SCOPE OF WORK. SEE DEMO

KEYNOTE 14. NOTE: SCHEDULE THIS

WORK SO AS TO REPLACE WITH NEW

AT EACH LOCATION ONCE AREA IS

REPAIRED, SO AS TO MINIMIZE BREAKS

IN THE BUILDING ENVELOPE.

NOTE CONTRACTOR TO

PROVIDE ALLOWANCE

FOR (8) 8ft 1x8 WALL SHEATHING

BOARDS / ADDRESS OF SHEATHING TO

BE REPLACED IN BASE BID TYP.

OPENING

POCKET DOOR

INTERIOR DOOR

EXTERIOR DOUBLE

PANEL DOOR

EXTERIOR SINGLE

PANEL DOOR

DOUBLE HUNG WINDOW

CASEMENT WINDOW

NEW WALL

CONSTRUCTION

EXISTING WALL

CONSTRUCTION

1 HR DUPLEX

PARTY WALL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

*** SAFETY PAYS ***

*** SUPPORT VALUE ENGINEERING - IT PAYS ***

F

IL

E N

A M

E

F

IL

E N

U M

B E

R

PLAN NORTH

A-102

S

T F

L O

O R

P L

A N

W R

IG

H

T -P

A T

T E

R S

O N

A F

B

D A

Y T

O N

O

H

IO

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G P

L

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

J W

IL

K

E R

S O

N

N B

E R

B E

R

IC

H

S D

E G

A R

O

R C

U R

R A

N

J A

N U

A R

Y

W Q

R -1

-F

-0

CERTIFIED FINAL FOR CONSTRUCTION

IM

P

R O

V E

F A

M

IL

Y H

O U

S

IN

G

P

F

IL

E N

U M

B E

R

TYPE G1/4" = 1'-0"A2

1ST FLOOR PLAN

0 2' 4' 8'

A m e n d m e n t

M

A R

C H

GENERAL NOTES: KEYNOTES

LEGEND

• ALL TYPICAL INTERIOR WALLS MAY BE FRAMED WITH WOOD OR EQUALLY SIZED

METAL STUDS AT A MAX OF 16" O.C. TYP. SEE STRUCTURAL SPECIFICATIONS

FOR ADDITIONAL REQUIREMENTS UNLESS OTHERWISE NOTED, WITH (1) LAYER

½” GYPSUM BOARD EACH SIDE. (PROVIDE GREEN BOARD @ ALL WET

LOCATIONS, PROVIDE CONCRETE BOARD AT ALL TILE LOCATIONS.) SEE

INTERIOR DRAWINGS FOR SCHEDULED FINISHES.

WALL LEGEND

1 1

1 1

03/10/21 W

2Q R

R

-0

A-301

A2

A-301

A1 A-202

D1 A-201

D1 A-202

A1 A-201

BEDROOM 3

BATH 2

BEDROOM 2

CL

HALL 2

STAIR

A

A

G G

G G

F

A

GG

10 10

7 7

201B

201A

202A

204A CLOSET

A-401

A1 203A

A1

A-302

A4

A-302

A8

A-302

A7

A-303

A4

A-3…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .