PART3of4AM-06_DRAW.pdf

PDF 8 MB Posted

Attached to
Fort Irwin Replacement Hospital, Fort Irwin, San Bernardino County, California
Solicitation number
W912PL-12-R-0008
Issued by

About this file

Amendment 6 - Part 3 of 4 amended drawings

View the file

Other files

File Type Posted
am9_W912PL-12-R-0008.pdf PDF
am8_W912PL-12-R-0008.pdf PDF
Amended J A Redacted Version_13Feb2012.pdf PDF
am7_W912PL-12-R-0008.pdf PDF
am7_W912PL-12-R-0008.pdf PDF
PART2of4AM-06_DRAW.pdf PDF
PART4of4AM-06_DRAW.pdf PDF
PART1of4AM-06_DRAW.pdf PDF
am6_W912PL-12-R-0008.pdf PDF
PART2of3-DRAW-AM 5 - 02-02-12.pdf PDF
PART1of3-DRAW-AM 5 - 02-02-12.pdf PDF
AM-05_SPECS.pdf PDF
PART3of3-DRAW-AM 5 - 02-02-12.pdf PDF
am4_W912PL-12-R-0008.pdf PDF
Hospital Business Forum-Site Walk Attendee list 01-18-12.pdf PDF
am3_W912PL-12-R-0008.pdf PDF
am2_W912PL-12-R-0008.pdf PDF
am1_W912PL-12-R-0008.pdf PDF
J A_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_5A_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_5B_150 shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1F_30 shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3D_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_4B_97shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_4A_150shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1C_25shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6E_6shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1D_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_5C_202shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6F_5shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_2B_173shts_W912PL-12-R-0008.pdf PDF
Spec_Vol 1_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6D_112shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6C_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6A_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3A_25shts_W912PL-12-R-0008.pdf PDF
Spec_Vol 3_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6B_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3C_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1E_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_2A_200shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3E_105shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1A_50shts_W912PL-12-R-0008.pdf PDF
Spec_Vol 2_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1B_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3B_25shts_W912PL-12-R-0008.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

9'

- 0

" M

IN

R

20°

(V

AR

IE

S)

2'

- 0

1/ 8"

2' - 7"

9' - 0" 5' - 0"

12' - 0" 6' - 0"

18' - 0" (PARKING SPACE)

107326.B02

107326.B01 107326.B01

AS010

AS010

SIM

14' - 0"

9 033100.A06

AS003

TO STEEL

13' - 0"7

034501.A04

AS010

4' - 0"9' - 0"9' - 0"9' - 0"4' - 0"

35' - 0"

107326.B02 107326.B01

EQEQEQ

2 5

107326.C01

107326.B01

AS010

4' - 0"9' - 0"9' - 0"9' - 0"4' - 0"

EMP-5

EMP-5

AS003

034501.A04

034501.A04

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

As in dic ate d

AM-06

AS010

PA

RK

IN

G

TR

EL

LIS

D

ET

AI

LS

Au tho r

De sig ne r

Ch ec ke r

AS

1 FRONT OF PARKING SPACE

2 CORRUGATED PERFORATED ALUMINUM

PANEL (10% OPEN). FINISH TO MATCH

CANOPY SYSTEM

3 TAPER BEAMS

4 CANTILEVER

5 PARKING STRIPE BELOW

6 PAVEMENT

7 ADJUST HEIGHT AS REQUIRED TO

MAINTAIN LEVEL STRUCTURE @ GRADE

VARIATIONS

8 OPEN

9 CONCRETE FOOTING PER STRUCTURAL

DWGS.

10 NOT USED.

11 LIGHT FIXTURE, REFER TO ELECTRICAL

DRAWINGS

12 SECURITY CAMERA, REFER TO

ELECTRICAL SITE UTILITY DRAWINGS FOR

LOCATIONS AND QUANTITIES

13 ELECTRICAL BACK BOX, SEE ELECTRICAL

DRAWINGS

14 JUNCTION BOX AND LED POWER SUPPLY.

15 RIGID ELECTRICAL CONDUIT, SECURE AS

REQUIRED. PAINT TO MATCH STRUCTURE.

16 ELECTRICAL CONDUIT TO HANDHOLE, SEE

ELECTRICAL SITE DRAWINGS FOR

LOCATION.

17 ELECTRICAL CONDUIT TRANSITIONS.

18 LOW VOLTAGE CABLE. PROVIDE

GROMMETS TO AT ALL CABLE

PENTRATIONS THROUGH STRUCTURE.

19 VIDEO SURVEILLANCE SYSTEM POWER

SUPPLIES. PAINT TO MATCH STRUCTURE.

20 CONCRETE WHEEL STOP BELOW. SEE

CIVIL DRAWINGS

MATERIAL NOTES

033100.A06 CONCRETE FOOTING

034501.A04 PRECAST CONCRETE BASE

107326.B01 SUPPORT STRUCTURE

107326.B02 COLUMN

107326.C01 ROOF PANEL

A. REFER TO SHEETS AS003 AND AS004

FOR LAYOUT OF PARKING TRELLIS

CANOPY

B. REFER TO SPECIFICATION SECTION

107326 FOR PARKING TRELLIS CANOPY

FABRICATION & ENGINEERING

C. FABRICATOR MUST FOLLOW DESIGN

INTENT OF THESE DRAWINGS

D. FOR ADDITIONAL INFORMATION ON

EXTERIOR MATERIALS SEE

SPECIFICATION SECTION 090690

E. WHERE COLOR IS SHOWN AS BEING

SPECIFIC TO ONE MANUFACTURER, AN

EQUIVALENT COLOR BY ANOTHER

MANUFACTURER MAY BE SUBMITTED

FOR APPROVAL. MANUFACTURERS AND

MATERIALS SPECIFIED ARE NOT

INTENDED TO LIMIT THE SELECTION OF

EQUAL COLORS FROM OTHER

MANUFACTURERS.

F. PROVIDE STAINLESS STEEL SCREWS

AND ANTIGALVANIC PADS OR COATING

TO SEPARATE ALL METAL EQUIPMENT

AND CONDUIT MOUNTED TO ALUMINUM

CANOPY SYSTEM

3/8" = 1'-0"

SECTION3

3/8" = 1'-0"

FRAMING PLAN1 3" = 1'-0"

SECTION DETAIL4

3/8" = 1'-0"

FRONT ELEVATION2

EXTERIOR COLOR SCHEDULE

EMP-5 EXTERIOR METAL PANEL, CENTRIA

SUNDANCE AM, COLOR: 9962 XL SILVER

GRAY

EPC-1 SPEC SECTION: 34500 / PRECAST LIGHT

3/8"=1'-0" GRAPHIC SCALE

1'01' 3' 5' 9'

15"10"5"2"

3"=1'-0" GRAPHIC SCALE

01"

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

OU

S

CH

AN

GE

S

-0 7-

BK

H

AS011

N2288139.7413 E6955240.4247 6

055913.A01

034500.A01

1' - 0"

FOR RAMP LENGTH

SEE CIVIL DRAWINGS 1' - 0"

1'

- 9

1'

- 3

3'

- 0

055200.R06

AS011

Sim

AS011

25°

25°

25°

25°

25°

25°

25°

5°

R 276"

R 432"

R 252"

034500.A01

033100.A06

N2288139.7413 E6955240.4247

033100.A06

TYP.

TYP.

EQ

EQ

EQ

EQ

EQ

1' - 8"

9'

- 0

034500.A01

034500.A01

EQ. 12' - 11 7/8" EQ.

17' - 8 5/8"

EPC-1

EMP-5

055913.A01

033100.A06

7'

- 1

3' - 0" SQUARE4' - 0" SQUARE 1'

- 4

1'

- 0

033000.A05033000.A05

033000.A05

033100.A06

3'

- 0

1'

- 3

1'

- 9

4" 6"

1 3/4" 2 3/4"

9"

1"

2"

10"

R 1" 1/4" 1"

3"

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

As in dic ate d

AM-06

AS011

TR

EL

LIS

P

LA

N

AN

D

DE

TA

ILS

Au tho r

De sig ne r

Ch ec ke r

AS

1/8" = 1'-0"

CIRCULAR TRELLIS PLAN - 22

25'0 5' 15'

1/8"=1'-0" GRAPHIC SCALE

5'

1" = 1'-0"

TYP SITE RAMP HANDRAIL4

N

1 POSTS AT 5' MAX

2 1 1/2" OD PIPE, SEE SPECIFICATIONS FOR

FINISH

4 1" RECESS

5 SLOPE PER CIVIL DRAWINGS

6 COORDINATE WITH HARDSCAPE PATTERN

ON LH104

7 ALUMINUM PROFILE

8 REFER TO DETAIL 6/H-AE420

9 4 #5 EACH WAY AT BOTTOM

10 3 #5 EACH WAY AT BOTTOM

7'-6"5'2'-6"6"0

1/2"=1'-0" GRAPHIC SCALE

6"

3'-6"1'-6"6"0

1"=1'-0" GRAPHIC SCALE

6"

A. REFER TO SHEETS AS003 AND AS004

FOR LAYOUT OF PARKING TRELLIS

CANOPY

B. REFER TO SPECIFICATION SECTION

107326 FOR PARKING TRELLIS CANOPY

FABRICATION & ENGINEERING

C. FABRICATOR MUST FOLLOW DESIGN

INTENT OF THESE DRAWINGS

D. FOR ADDITIONAL INFORMATION ON

EXTERIOR MATERIALS SEE

SPECIFICATION SECTION 090690

E. WHERE COLOR IS SHOWN AS BEING

SPECIFIC TO ONE MANUFACTURER, AN

EQUIVALENT COLOR BY ANOTHER

MANUFACTURER MAY BE SUBMITTED

FOR APPROVAL. MANUFACTURERS AND

MATERIALS SPECIFIED ARE NOT

INTENDED TO LIMIT THE SELECTION OF

EQUAL COLORS FROM OTHER

MANUFACTURERS.

F. PROVIDE STAINLESS STEEL SCREWS

AND ANTIGALVANIC PADS OR COATING

TO SEPARATE ALL METAL EQUIPMENT

AND CONDUIT MOUNTED TO ALUMINUM

CANOPY SYSTEM

MATERIAL NOTES

033000.A05 CONCRETE FLOOR

033100.A06 CONCRETE FOOTING

034500.A01 PRECAST CONCRETE SHAPE

055200.R06 ALUMINUM TUBE HANDRAIL

055913.A01 TRELLIS FRAMING SYSTEM

1/8" = 1'-0"

CIRCULAR TRELLIS PLAN - 11

1/2" = 1'-0"

TRELLIS SECTION3

EXTERIOR COLOR SCHEDULE

EMP-5 EXTERIOR METAL PANEL, CENTRIA

SUNDANCE AM, COLOR: 9962 XL SILVER

GRAY

EPC-1 SPEC SECTION: 34500 / PRECAST LIGHT

1" = 1'-0"

SECTION5

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

OU

S

CH

AN

GE

S

-0 7-

BK

H

1" = 1'-0"

TRELLIS PROFILES6

1 1

AS

057300.A03

AS012

057300.A03 TYP.34 033100.A12

033100.J01 5

10' - 0" TYP. 30' - 0" TYP.

EQ. EQ. EQ.

AS

057300.A03 TYP.3

033100.A12 4

033100.J01 5

10' - 0" TYP. 2

057300.A03 TYP.

H-AE542

SIM

2'

- 6

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

As in dic ate d

AM-06

AS012

SI

TE

D

ET

AI

LS

Au tho r

De sig ne r

Ch ec ke r

AS

25'0 5' 15'

1/8"=1'-0" GRAPHIC SCALE

5'

A. ARCHITECTURAL SITE PLAN PROVIDED

FOR OVERALL COORDINATION. REFER

TO CIVIL, LANDSCAPE AND

ENGINEERING SITE PLANS FOR

CONSTRUCTION DOCUMENT

INFORMATION.

B. REFER TO H-AG610 FOR EXTERIOR

SIGNAGE SCHEDULE AND H-AG506 -

H-AG508A FOR DETAILS

1 GRADE, SEE CIVIL DRAWINGS

2 TOP OF WALL, SEE CIVIL DRAWINGS

3 REFER TO 6/H-AE542

4 PROVIDE TEXTURED CONCRETE COATING

ON ALL EXPOSED SURFACES

5 REFER TO 5 & 8/H-AE521

MATERIAL NOTES

033100.A12 CONCRETE RETAINING WALL

033100.J01 CONSTRUCTION JOINT

057300.A03 STAINLESS STEEL DECORATIVE RAILING

1/8" = 1'-0"

SCREEN WALL ELEVATION1

1/8" = 1'-0"

SCREEN WALL ELEVATION2 1/8" = 1'-0"

SCREEN WALL ELEVATION3

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

OU

S

CH

AN

GE

S

-0 7-

BK

H

1/2" = 1'-0"

CUP SCREEN WALL SECTION4

A

B.1 E G I K.3

1.1

27' - 7 1/2" 14' - 8 1/2" 14' - 8 1/2" 27' - 7 1/2"

2"

7 1

/2"

NCOIC PM

CHIEF PM

FORMS

RECEPT

101A

MECH (AHU)

MASK FIT

HEAR TECH

OH PROVIDER

CONF / CLASS

AUDIOBOOTH

OH EQUIP

EXAM / EKG

COMM

F TLT

M TLT

PH RN TECH

NCOIC PDH

PH RN

PDH EXAM

PH RN

IMMUNIZATION

2B

2A

WAIT

CORRIDOR

CO

RR

ID

OR

CORRIDOR

CO

RR

ID

OR

SOILED UTILITY

ELEC

100E

REF LINE

M-AE113

R

EF

L

IN

E

M -A

E1

REF LINE

M-AE113

M-AE401

JANITOR

E03A

B00D

E03A

E03A E03AE03A

E03A

2M-AE501

TYP

TYP

WORK

E03A

B00D

RECORDS

TYP

SHEET NOTES:

N

25'0 5' 15'

1/8"=1'-0" GRAPHIC SCALE

5'

1 2

3 4

KEY PLAN

M

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

8"

1' -0

AM-06

M-AE111

FL

OO

R

PL

AN

, A

RE

A

MN

H

TJ

H

PA

W

M-

AE

1 REMOVE CONCRETE SLAB IN THIS AREA TO INSTALL

OR DEMOLISH PLUMBING. REINSTALL VAPOR

BARRIER AND 6" CONCRETE SLAB. PROVIDE #4

BARS @ 18" EA. WAY & DOWEL INTO ADJACENT SLAB

WITH EPOXY GROUT. THIS IS TYPICAL IN ALL FOUR

AREAS OF THE FLOOR PLAN.

2 CURRENTLY EXISTING WALLS EXTEND TO

UNDERSIDE OF GYP BD DECK AT UNDERSIDE OF

TRUSS. THESE EXISTING WALLS NEED TO BE

UPGRADED TO BECOME SMOKE TIGHT. SHALL BE

CAULKED AND SEALED AT ALL HOLES, GAPS AND

PENETRATIONS.

3 PAINT TO MATCH WALLS

4 EMERGENCY SHOWER

A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL

ABBREVIATIONS AND ARCHITECTURAL SYMBOLS

B. DIMENSIONS ARE TO COLUMN GRID, FACE OF

MASONRY OR CONCRETE, FACE OF METAL STUD

UON.

C. ALL INTERIOR PARTITIONS ARE TYPE E03A UNO. SEE

SHEETS H-AE561 THRU H-AE565 FOR PARTITION

TYPES

D. ALL DIMENSIONS FOR OPENING SIZES ARE NOMINAL

E. DIMENSIONS SHOWN FOR EXISTING BUILDING ARE

APPROXIMATE AND SHOULD BE VERIFIED. EXISTING

COLUMN LINE DIMENSION ARE FOR REFERENCE

ONLY

F. PATCH EXISTING WALLS AT ALL LOCATIONS WHERE

ADJACENT PARTITIONS ARE REMOVED.

G. PATCH CONCRETE FLOORS AT ALL PLUMBING PIPE

REMOVAL, TYP.

H. SEE M-AE501 FOR TYPICAL DETAILS WHERE NEW

AND EXISTING PARTITIONS MEET.

I. WHERE EXISTING ROOMS ARE CONVERTED TO

SMOKE TIGHT, SEAL ALL WALL PENETRATIONS.

PROVIDE NEW SMOKE SEALS AND CLOSERS AT

EXISTING DOORS.

J. PATCH WALLS AT LOCATIONS OPENED FOR

PLUMBING WORK AND WALLS WHERE SINKS

REMOVED. Sy m De sc rip tio n

Da te

Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0

7-

BK

H

1.1

CONF / CLASS

CLR02

AUDIOBOOTH

PEHS3

RECORDS

SRE01

101A

RECEPT

RECP1

EXIST MECH (AHU)

F TLT

TLTF2

EXAM / EKG

EXRG1

PDH EXAM

EXRG1

COMM

M TLT

TLTM2

NCOIC PDH

OFD01

PH RN

EYVS1

HEAR TECH

OFA03

100E

ELEC

MRS01

VISION SCREEN

LBIH1108

NCOIC PM

OFA02

CHIEF PM

OFA02

IMMUNIZATION

SRS01

FORMS/COPY

RPR01

WORK

OFA03

A

A

A

C E0

C

T0

C

L0

A5145

A5145

A5145

A5145

M0045

A5145

A5145

M

A5145

A5145

A5145

A5145

A1066 A5080

P5210 P2450 A5145

A5145

A1066 A5080

L2250

A

A

A

A

A5180A

A

E

CS150

A5080

4"

WAIT

A5

0A

102613.R01

102613.R01

102613.R01

102613.R01

10' - 10"

8'

- 1

1" 4"

M-QE200

C

Q

1'

- 3

OH PROVIDER

SRS01

A

A

A1066 A5080

A1066 A5080

A

A

A

A

PH RN

OFA03

A5145

A5145

A1066 A5080

PH RN TECH

SRE01

C S1

A5180A

C S1

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE111

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

Au tho r

De sig ne r

Ch ec ke r

M-

QE

MATERIAL NOTES

102613.R01 HANDRAIL

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

O.3 Q S U W.9

1.1

IH OFFICE

OFD01

IH TECH

EXRG1

EH OFFICE

OFD01

ONLINE FORMS

OFA03

PDH EQUIP

SRE01

516A

TLT

TLTU1

516B

TLT

TLTU1

WATER LAB

OFA02

WATER LAB

LBWA1

EH EQUIP

SRE01

NCO EH

OFA02

INTERVIEW

OFA02

IH LAB

LBIH1

EH TECH

OFA02

MECH (BOILER)

CORRIDOR

OFA03

MECH (CHILLER)

MULTIPURPOSE

OFA03

IH EQUIP

SRE01

EH TECH

OPIR1

MECH (AHU)

A

A

A5145

A5145

CS150

C03J0

CE030

A1066

A5080

C04P0

CT070

C0044

C03H0

CE030

CE030

A

A

A

A

45 A

A

A5180A

M-QE200 3

P2000 P2450

A

E

L2210

1'

- 8

A

A

M0400

F3060

P

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE112

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

Au tho r

De sig ne r

Ch ec ke r

M-

QE

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

IMD INSTRUCT

OFA03

OIC EDUCATION

OFA02

CHIEF HET

OFA02

NCO INSTRUCT

OFA03

STORAGE

COMC1

INSTRUCTORS

OFA03

STORAGE

SRS01

COPY/FILES

RPR01

COPY/FILES

FILE1

RECEPT

RECP1

STORAGE

ENEL01

200E

ELEC

SRSE1

CLASS

CLR01

COMP TRAINING

CLR03

CONF

CLR01

A5145

A5145

A5145

A5145

M0400

F3

M0400

F3060

5' - 2 1/2" 14' - 6"

102613.R01

102613.C12

102613.R01

102613.R01

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE113A

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

3A

Au tho r

De sig ne r

Ch ec ke r

M-

QE

3A

MATERIAL NOTES

102613.C12 SURFACE MOUNTED RESILIENT

CORNER GUARDS

102613.R01 HANDRAIL

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

K.3

L

CLERK

OFA03

COPY

RPR01

FILE

FILE1

SIPR

SSS01

MTF EMER MNGR

OFA02

WAIT

WRC01

SEC

OFA02

A

A

102613.R01

102613.C12

102613.R01

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE113B

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

3B

Au tho r

De sig ne r

Ch ec ke r

M-

QE

3B

MATERIAL NOTES

102613.C12 SURFACE MOUNTED RESILIENT

CORNER GUARDS

102613.R01 HANDRAIL

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

L

NCO MOBILIZ

OFA02

SECURITY MNGR

SEC01

CMD MEDCO

OFA02

SUPPLY SGT

OFA02

NCOIC PTMS

OFA02

1SGT

OFA02

A5145

A5145

A

A

A

A

A5145

A5145

A

A

A5145

A5145

311A

STAFF TLT

311B

PAT TLT

102613.R01

102613.R01

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE113C

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

3C

Au tho r

De sig ne r

Ch ec ke r

M-

QE

3C

MATERIAL NOTES

102613.C12 SURFACE MOUNTED RESILIENT

CORNER GUARDS

102613.R01 HANDRAIL

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

O.3N

L

M O

BADGES

OFA02

CONF

CRA01

STORAGE

SRS01

WAIT

WRC01

A

A

M

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE114A

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

4A

Au tho r

De sig ne r

Ch ec ke r

M-

QE

4A

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

O.3 Q S U W.9

OPEN OFFICE

OFA03

OPEN OFFICE

OFA03

OPEN OFFICE

OFA03

OPEN OFFICE

OFA03

M TLT

TLTM2

F TLT

TLTF2

615A

COMM

LOUNGE

SL001

CHIEF RMD

OFA02

CHIEF BUDGET

OFA02

COPY

RPR01

ASSIST

SEC01

OPEN OFFICE

OFA03

FILES

FILE1

ELEC

TLT

TLTU1

A5145

A5145

A

F3050

CT070

C04P0

C02D0

CB020

C02C0

A5080

A5145

A5145

A5145

A5145

P

P

A5

9A

A

A5

9B

A5

0A

A1

A5

1' - 4"

OPEN OFFICE

OFA03

M-QE2001

CB020

102613.C12

102613.C12

102613.R01

102613.R01102613.C12

CS150A

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE114B

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

4B

Au tho r

De sig ne r

Ch ec ke r

M-

QE

4B

MATERIAL NOTES

102613.C12 SURFACE MOUNTED RESILIENT

CORNER GUARDS

102613.R01 HANDRAIL

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

L

M O

MTF EMER MNGR

OFA02

AMAP

OFA02

NCO TDY

OFA02

COPY

RPR01

MEPRS

OFA03

LOUNGE

SL001

CHIEF PERS

OFA02

CHIEF PTMS

OFA02

DEP CHIEF PERS

OFA02

PERS CLERK

OFA03

TLT

TLTU1

TLT

TLTU1

JAN

JANC1

FILES

FILE1

COPY

RPR01

HR

OFA02

CHIEF MNPWR

OFA02

A5145

A5145

A

80 C T0

C

P0

C

D

C B0

C

C

A

F3

A5145

A5145

A5145

A5145

A5145

A5145

A

A

A

A

A

A

A

A

A

A

PERS CLERK

OFA03

P

A

P

A5

9A

A5

A5

9B

A5

0A

A

A

P

00 A5

9A

A5

A5

9B

A5

0A

A

A

1' - 3 1/2" 1' - 3"

M-QE200

C B0

102613.R01

102613.R01

102613.R01

102613.C12 102613.C12

C S1

A

A.

B.

C.

D.

SEE B4/H-QE200 FOR EQUIPMENT MOUNTING HEIGHTS

SEE A4/H-QE200 FOR TYPICAL TOILET ROOM

ELEVATIONS AND ADDITIONAL DIMENSIONS.

VERIFY LOCATION OF BULLETIN OR MARKER BOARDS

WITH RESIDENT ENGINEER PRIOR TO INSTALLATION OF

BLOCKING. PROVIDE WALL FINISH BEHIND THESE

ITEMS.

SEE SPEC SECTION 11 70 00 FOR EQUIPMENT AND

CASEWORK SCHEDULES.

LEGEND:

CATEGORY A, E AND F

CATEGORY C

CATEGORY A, CEILING MOUNTED

CATEGORY DESCRIPTION

CONTRACTOR FURNISHED AND

CONTRACTOR INSTALLED

A

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

C

GOVERNMENT FURNISHED AND

CONTRACTOR INSTALLED

E

GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED

F

CORNER GUARD, TYPICAL.

SEE DETAILS 9/H-QE500

HANDRAIL, TYPICAL. SEE DETAIL

10/H-QE500

E. CATEGORY C ITEMS ARE SCREENED AND

SHOWN FOR COORDINATION PURPOSES

ONLY - NOT IN CID CONTRACT

SHEET NOTES:

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

1A

KEY PLAN

M

1B 2A 2B

3A 3B

3C 4B4A

4C

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

M-QE114C

EQ

UI

PM

EN

T

PL

AN

, A

RE

A

4C

Au tho r

De sig ne r

Ch ec ke r

M-

QE

4C

MATERIAL NOTES

102613.C12 SURFACE MOUNTED RESILIENT

CORNER GUARDS

102613.R01 HANDRAIL

Sy m

De sc rip tio n Da te Ap pr ov ed

NO

TE

R

EV

IS

IO

N

-0 7-

BK

V-1

034500.A03

051200.A01 092423.A01

033100.A05

EPC-1

034500.A03

EPC-1

TOP

VARIES

V-AE502

075423.A01 072200.P02

072200.R02

053000.A07

092200.D81

TOC

VARIES7

033100.V01

310000.C02

310000.C01

310000.A02

V-1

051200.A01

033100.A05

033100.A06

051200.B03

092423.A01

075423.A01

076000.M04

TOP

VARIES

V-AE502

2 SIM.

072200.P02

072200.R02 053000.A07

092200.D81

099000.A02 5

033100.G01

TOC

VARIES

310000.C02 310000.C01 310000.A02

033100.V01

031500.J05

051200.E10

051200.E01

TOC

0' - 0"

V-B

034500.A03

034500.A01

3/4

3/

4" 1/2

" 1' - 0"

8'

- 0

2' - 0"

033100.A06

079200.Q02

V-AE502

1 SIM.

9'

- 0

051200.E10 051200.E01

033100.G01033100.G01

051200.B03

051200.A02

TOC

0' - 0"

V-B

034500.A01

034500.A03

3/4

4" 1'

- 5 1/

4"

1'

- 1

0"

1/2

3/

4" 3/4

8'

- 0

079200.Q02

1' - 0" 1' - 0"

EPC-1

9'

- 0

033100.G01 033100.A06

051200.E01 051200.E10

034500.A03

3' - 6"

5'

- 0

1'

- 0

1'

- 0

2' - 10"

051200.E10

055013.T03 051200.E01

051200.B03

2' - 0"

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

2"

1' -0

AM-06

V-AE312

W

AL

L S

EC

TI

ON

S

PK

L

GT

S

Ch ec ke r

V-

AE

1/2" = 1'-0"

WALL SECTION 22 1/2" = 1'-0"

WALL SECTION 11

1 BEYOND

2 OPENING THROUGH PRECAST,

REFER TO ELEVATIONS

3 SEE STRUCTURAL DWGS FOR BEAM

SIZE & LOCATION

4 PROVIDE BACKER ROD & SEALANT

AT ALL PANEL JOINTS

5 APPLY COATING TO "UNFINISHED"

PRECAST SURFACES ONLY

6 UNFINISHED SIDE OF PRECAST

PANEL SHALL FACE INTERIOR

TYPICAL

7 REFER TO CIVIL GRADING PLANS

FOR FINISHED ELEVATIONS

8 TOC DATUM 0'-0" = 2522.29. FIN SLAB

SLOPES FOR DRAINAGE. REFER TO

CIVIL DRAWINGS FOR GRADING &

ADDITIONAL INFORMATION

9 STEEL DOWLS SET IN EPOXY. SIZE

AND QUANITY TO BE DETERMINED

BY CONCRETE PRECASTER.

10 6" X 3 1/2" X 3/8" STAINLESS STEEL.

11 PRECAST CONCRETE SIGN WALL.

EPC-1

12 SEE 1/V-AE502 SIM FOR

CONTINUATION

13 WF-3.5 SEE V-SB601

A. SEE SHEETS GI009 AND GI010 FOR GENERAL

ABBREVIATIONS AND ARCHITECTURAL

SYMBOLS.

B. REFER TO CIVIL DRAWINGS FOR FINISH

GRADE.

EXTERIOR FINISH SCHEDULE

EPC-1 EXTERIOR PRECAST PANEL,

GATE PRECAST KISSIMMEE, MIX

PCI 113 SANDBLAST

7'-6"5'2'-6"6"0

1/2"=1'-0" GRAPHIC SCALE

6"

MATERIAL NOTES

031500.J05 PREFORMED JOINT FILLER

033100.A05 CONCRETE FLOOR

033100.A06 CONCRETE FOOTING

033100.G01 GROUT SOLID

033100.V01 VAPOR BARRIER

034500.A01 PRECAST CONCRETE SHAPE

034500.A03 PRECAST CONCRETE WALL

PANEL

051200.A01 STEEL BEAM

051200.A02 STEEL WIDE FLANGE BEAM

051200.B03 STEEL TUBE COLUMN

051200.E01 STEEL ANGLE

051200.E10 EMBEDDED STEEL PLATE

053000.A07 STEEL ROOF DECK

055013.T03 EXPANSION BOLT

072200.P02 GLASS MAT GYPSUM

PROTECTION BOARD

072200.R02 ROOF INSULATION BOARD

075423.A01 SINGLE PLY THERMOPLASTIC

ROOFING SYSTEM

076000.M04 PARAPET COPING

079200.Q02 BACKSTOP AND SEALANT

092200.D81 FURRING CHANNEL,

HAT-SHAPED

092423.A01 STUCCO

099000.A02 TEXTURED COATING

310000.A02 FILL MATERIAL

310000.C01 CAPILLARY WATER BARRIER

310000.C02 SAND CUSHION

1/2" = 1'-0"3 WALL SECTION @ SCREENWALL

1/2" = 1'-0"4 WALL SECTION AT SCREENWALL OPENING

1/2" = 1'-0"5 RAISED FOUNDATION

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

O U

S

CH

AN

GE

S

-0 7-

BK

P-A

P-B

P-C

P-4 P-3 P-1

40' - 8"

6'

0"

0"

91' - 0"

WF-4.0

W F-

2.

W F-

4.

WF-2.0

WF-2.0

W F-

4.

50' - 4"

REF LINE

P-SB102

WF-2.0

WF-2.0W

F-

2.

W F-

2.

W F-

2.

SJI

SJI

SJI

SJI

SJI

SJI

SJI

SJI SJI

SJI

SJI

SJI

SJI

SJI

SJI

SJI

SJI

SJI SJI

SJI

SJI

SJI

SJI SJI

SJI

SJI

SJI

SJI SJI

SJI

SJI

SJI

SJI SJI

SJI

SJI

SJI

SJI

SJI SJI

SJI

SJI

SJI

SJI SJI SJI SJI

SJI

SJI

SJI SJI

SJI

SJI

SJI

SJI

SJI SJI SJI SJI

SJI SJI SJI

SJI SJI SJI SJI

SJI SJI SJI

F-7.0 F-7.0 F-7.0

F-7.0

F-7.0

F-7.0

F-7.0

F-7.0F-7.0F-7.0F-6.0X11.0

SJI SJI

SIM

N.3

8.5 9.2 10.1 11 12

P-SB503

P-SB501

P-SB501

P-SB501

P-SB503

P-SB503

P-SB501

P-SB503

P-SB503 2

P-SB503

P-SB501

9'

/2

HSS8X8X3/8

F-5.0

HSS8X8X3/8

F-5.0

HSS8X8X3/8

F-5.0

HSS8X8X3/8

F-5.0

P-SF401

TC-1

TC-1

TC-1

TC-1

1' - 6 1/2"13' - 4"

TC-1

TC-1

TC-1

TC-1

TC-1

TC-1

TC-1

TC-1

SF

-2

'-0

SF

-2

'-0

SF

-2

'-0

SF

-2

'-0

SF

-2

'-0

P-SB503

P-SB503

P-SB503

SF -2'-0"

SF -2'-0"

SF -2'-0"

SF -2'-0"

SF -2'-0"

T/FTG

-4'-0"

T/FTG

-6'-0"

T/FTG

-8'-0"

T/FTG

-10'-0"

T/FTG

-12'-0"

T/FTG

-12'-0"

P-SF401

2 ABOVE

W F-

2.

WF-2.0

F-6.0X11.0 F-7.0

F-7.0

F-7.0

F-7.0 F-7.0

16' - 5 1/2" 5' - 0" 9' - 9" 9' - 9" 9' - 9" 8' - 5 1/2"

1'

3" 9'

0"

9'

0" 1'

3"

6' - 8 1/2" 5' - 0"

8 8

8 8

8 8

8 8

TC-1

9C-1 F-4.0

(TYP 12 LOCATIONS)

TC-1

P-SB502

P-SB502

P-SB502

M J

M J

MJ

MJ

MJ

MJ

MJ

SIM

T/FTG

-6'-0"

P-SB503

P-SB502

P-SB503

P-A.8

P-A.3

WF-2.0

P-SB503

P-SB503

P-SB503

(TYP 9

LOCATIONS)

A.

B.

C.

D.

E.

F.

SEE SG000 SERIES FOR STRUCTURAL

NOTES, ABBREVIATIONS AND SYMBOLS.

SEE SB500 SERIES FOR FOUNDATION

SECTIONS AND DETAILS.

SEE SF600 SERIES FOR SCHEDULES AND

DIAGRAMS.

COORDINATE SLAB RECESSES, FINISHES,

JOINTS, ETC. w/ ARCH DRAWINGS.

COORDINATE FOUNDATIONS WITH OTHER

TRADES. STEP OR SLEEVE FOUNDATIONS

AS NEEDED, SEE SB500 SERIES.

DIMENSIONS ARE TO COLUMN GRID, FACE

OF MASONRY OR CONCRETE, OR

CENTERLINE OF STRUCTURAL STEEL, UNO.

0'-0" (REF) = 2508.33' (ACTUAL)

T/SLAB (TYP UNO)

-2'-0"

T/FTG (TYP UNO)

6" CONCRETE SLAB REINF w/ #4 @ 12" OC

EW OVER DAMP 2" PROTECTIVE SAND

CUSHION AND 15 MIL POLY SHEET VAPOR

RETARDER OVER 4" CAPILLARY WATER

BARRIER ON COMPACTED SUBGRADE.

8" CMU WALL GROUT SOLID & REINF w/ #6 @

24" OC VERT & MATCHING DOWEL AT

CORNERS, INTERSECTIONS AND EACH SIDE

OF WALL OPENINGS AND BOND BEAMS w/

#5 @ 40" OC HORIZ. PROVIDE POURED

CONC BOND BEAM @ 14'-8". SEE DETAIL 7/P-

SF505. COORDINATE w/ PRECAST PANEL

ELEVATION.

16"x16" REINFORCED CONCRETE COLUMNS

C-1 SUPPORTING PRECAST PANELS. TOP

OF COL = 14'-0".

8" CMU WALL REINF w/ #5 @ 48" OC VERT &

MATCHING DOWEL AT CORNERS,

INTERSECTIONS AND EACH SIDE OF WALL

OPENINGS AND #5 @ 48" OC HORIZ.

8" (ACTUAL DEPTH) CONC SLAB REINF w/ #6 @ 10" OC EW OVER 20'-0"x8'-0"x12'-0" DEEP

SUMP PIT. SEE 6 & 7/P-SB503 COORDINATE

OPENING SIZES AND LOCATIONS w/MEP.

3'-0" x 3'-0" x 2'-0" SUMP. DETAIL 9/P-SB501

SIMILAR.

EQUIPMENT PAD TYPE A PER DETAIL

2/P-SB502.

EQUIPMENT PAD PER TYPE D PER DETAIL

2/P-SB502.

COOLING TOWER SUPPORT LOCATIONS TO

BE COORDINATED w/ MEP &

MANUFACTURER REQUIREMENTS. SEE

DETAIL 2/P-SF505.

TC-1: CONCRETE TIE COLUMN SEE DETAIL

6/P-SB502 AND 3/P-SF601.

SEE CIVIL FOR COORDINATES AT

GRIDLINES PA-P4.

MJ: MASONRY JOINT, SEE DETAIL 4/P-SB502.

KEY NOTES:

12" CONCRETE PAD FOR PIPE SUPPORTS,

REINF w/ #6 @ 12" OC EACH WAY T&B. SEE

DETAIL 2/P-SB502 SIMILAR. COORDINATE

LOCATIONS AND SIZES w/ MEP.

N

25'0 5' 15'

1/8"=1'-0" GRAPHIC SCALE

5'

KEY PLAN

P

SHEET NOTES:

NOTES:

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

8"

1' -0

AM-06

P-SB101

LE

VE

L 1 , Z

ON

E

1 - F

OU

ND

AT

IO

N

AN

D

SL

AB

O

N

GR

AD

E

PL

AN

SV

W

AJ

W

SL

S

P-

SB

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

OU

S

CH

AN

GE

S 1-

-1

BK

H

AD

DE

D

NO

TE

-0 7-

BK

H

BASE PLATE

HSS 10x10

COLUMN DIAMETERANCHORS HOLE MIN WASHER

DIAMETER

BASE PLATE SCHEDULE

PL-1 1/2"x18"x18" (4) 1 1/4"DIA 2 1/16" 2 7/8"

TO

A

B 4"

C

LR

COL

SEE PLAN & SCHED FOR SIZE & REINF

6'' P

RO

J

SE

E

FT

G

SC

HE

D

SEE SCHEDULE

BASE PLATE,

6" MIN CLR

COL BLOCKOUT (SEE PLAN)

1 1 /2'

1 1/2''

2'' NON-SHRINK GROUT

SEE PLAN

T/FTG

SEE PLAN

T/SLAB

3" CLR

3'' C

LR

F1554, 36 KSI THRD ROD ANCHORS

SEE SCHEDULE

PROVIDE ZINC COATING

ON ALL STEEL. SEE NOTE

S-11 ON SHEET P-SG002

1/4

HEAVY

HEX NUT

HOLE, SEE SCHEDULE

HEAVY HEX NUT & 3/8'' PL WASHER (T&B),

SEE SCHEDULE FOR SIZEFILL SOLID w/

CONCRETE UNO

C L I

C L I tw

"tw" SAME

AS COL

THICKNESS

TACK NUT

TO THRD

ROD

HSS 8x8 PL-1 1/2"x16"x16" (4) 1"DIA 1 13/16" 2 3/8"

COMPACTED SUBGRADE

2" PROTECTIVE SAND

CUSHION

4" CAPILLARY WATER

BARRIER

HSS 4x4 PL-3/4"x12"x12" (4) 3/4"DIA 1 5/16" 1 7/8"

2" C

LR

VAPOR

RETARDER

#4 BOT EW @ 12" OC

GRADE, SEE ARCH & CIVIL

CHAMFER

#5 EW T&B @ 12" OC

#3 EW @ 8" OC MAX

LIMITS OF

EQUIPMENT

BLDG SLAB

LIMITS OF

EQUIPMENT

CHAMFER

EXP JT MATERIAL

LIMITS OF

EQUIPMENT

ON SLAB

ISOLATED GENERATOR PAD

AT GRADE

A

B

C

SE

E

PL

AN

6" UN

O

12" UNO

CT

R

SE

E

PL

AN

3" C

LR

UN

O

0'

- 6

6" MIN

6" MIN

0'

- 8

3" C

LR

0' - 8"

UN

O

0'

- 6

1'

- 0

COMPACTED

SUBGRADE

2" PROTECTIVE

SAND

CUSHION

4" CAPILLARY

WATER

BARRIER

#3 EW @ 8" OC MAX

LIMITS OF

EQUIPMENT

BLDG SLAB

CHAMFER

ON SLABD

SE

E

PL

AN

4" UN

O

6" MIN

CT

R

COMPACTED

SUBGRADE

2" PROTECTIVE

SAND

CUSHION

4" CAPILLARY

WATER

BARRIER

2'

0"

VAPOR RETARDER

VAPOR RETARDER

#3 @ 12" OC

@ PERIMETER

#3 @ 12" OC

@ PERIMETER

STD 90° HK

#4 TIES FOR #11 BAR OR LARGER

#3 TIES FOR ALL OTHER BARS

MAX SPACING = LEAST COLUMN

DIMENSION OR:

10" OC MAX FOR #5 BARS

12" OC MAX FOR #6 & #7 BARS

16" OC FOR #8 BARS OR LARGER

NOTE: ALL COL VERTS SHALL

BE SHOP OFFSET BENT, EVEN IF

COL SIZE DOES NOT CHANGE.

SLOPE OF INCLINED PORTION SHALL

NOT EXCEED 1 IN 6. WHERE OFFSET

EXCEEDS 3" SEPARATE DOWELS

SHALL BE PROVIDED.

2" C

LR

SP

AC

ES

TY

P

TI

E

SP

AC

IN

G

2- 1/2

3"

EQ

EQ

1/2

T

YP

T

IE

S P

LA

P, S

EE

S

CH

ED

MATCHING DWL.

1"

3" 3"

SC

HE

D

SE

E

PL

AN

3" C

LR3" CLR

SEE PLAN & SCHED FOR SIZE & REINF

T/ COL

SEE PLAN

T/ FTG

SEE PLAN

PROVIDE PLASTIC SPACER OR

SLAB BOLSTER (4 SIDES) AT

TOP OF LAP & AT TOP OF FORM

TERMINATE COL REINF

w/STD 90DEGREE HOOK

C-1 16"x16"

8-#7 VERT

2-#3 TIES

"B" BARS T & B

FTG REINF

RW-1

(h) MAXMARK W tL1 A B b VERT

REINF

"A" BARS T & B

VERT REINF w/ MATCHING DWL

SEE ARCH FOR

SCORES/REVEALS

VERT REINF

WEEPHOLES AND/OR GRAVEL

& DRAINAGE PIPE, SEE CIVIL

CONTR TO EXERCISE CARE

AND/OR PROVIDE BRACING

TO PREVENT OVERLOADING

WALL DURING BACKFILL

OPERATION

2x4 CONT

KEYWAY

T/WALL

SEE PLAN

RETAINING WALL SCHEDULE

"W" "L1" "b" 3" CLR

2" CLR

LA

P

PE

R

SC

HE

D

2" C

LR

3"

C

LR

T/FTG

SEE PLAN

"t" h (

MA

X)

CO

OR

D w/ C

IV

IL

FO

R

LO

CA

TI

ON

S 1'

-6 " M

IN

-6" MIN, 3'-6" MAX (COORD

w/ CIVIL & ARCH)

SEE CIVIL FOR

GRADES @ HIGH SIDE

SEE CIVIL FOR

GRADES @

LOW SIDE

3'-0" 4'-0" 12"8" 8" #5@12" (#4@12" OC HORIZ)#5@12" 4-#4

3/4" CHAMFER (TYP)

h = GRADE DIFFERENTIAL FROM HIGH TO LOW SIDES.

3/8"x1" VERT JT ES

OF TIE BEAM

REINF CONT @ CONTROL JT

IN CONC TIE BEAM

REINF FILLED CELL ES

OF JT w/ 1-#5 VERT

KEEP JT FREE OF DEBRIS

DURING CONST

BACK-UP ROD AND

CAULK PER ARCH

STOP REINF IN

KNOCK-OUT BLK BM

1''

MJ

3/8'' JT

NOTE: 30'-0'' OC (MAX) TYP-UNO

STOP JT REINF

ON ES OF JT

MJ

3/8'' JT

3/8'' JT

AT TIE BM/BM

AT LINTEL BLOCK BM

AT FOUNDATION

NOTE:

EXTEND COL TO

UPPERMOST TIE BM &

TERM REINF w/ STD

HK 6" FROM T/BM

4-#6 VERT w/

#3 TIES @ 8" OC

STD 90° HK

DWLS TO MATCH

COL REINF w/

2-#3 TIESTURN 1/2 BLK

ON EDGE

EVERY 2ND

COURSE

PROVIDE SLAB BOLSTER

OR PLASTIC SPACER

4 SIDES (AT TOP &

MID-HT) MIN TO

MAINTAIN REQD

CONC COVER

1' - 4"

0'

- 8

" 0' - 1 1/2" CLR TO TIES - TYP

LA

P, S

EE

S

CH

ED

WALL FTG COL FTG, SEE PLAN

T/FTG

SEE PLAN

TC-1

T/FTG

SEE PLAN

ARCHITECTURAL

PRECAST, SEE ARCH

FOR SIZE & REINF

SEE PLAN & SCHED

GROUT SOLID

BELOW GRADE

POURED CONC AT

STEEL CONN,

PROVIDE MIN 4"

COVER FOR STEEL

SEE ARCH

T/PRECAST

C L I

GRADE OR

PAVEMENT,

SEE CIVIL

SEE DETAIL 1/P-SB503

FOR TYP CONN AT FTG.

ONE PER PANEL

GROUT SOLID

BELOW GRADE

3/16

TYP ARCH

SEE

COL

ARCH

SEE

L-6x3 1/2x5/16x0'-4"

LONG (LLH), ONE

PER PANEL

HSS COL, SEE PLAN

EMBED BY

PRECAST MFR

SEE DETAIL

1/P-SB502

FOR BASE PL

& ANCHORS

3/16

TYP

SC

H

ED

SE

E

FT

G

3" CLR TYP

3" C

LR

2"

C

LR

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

3/

4"

1' -0

AM-06

P-SB502

FO

UN

DA

TI

ON

S

EC

TI

ON

S

AN

D

DE

TA

ILS

SV

W

AJ

W

SL

S

P-

SB

3/4" = 1'-0"

HSS COLUMN/FTG DETAIL1

3/4" = 1'-0"

TYP EQUIPMENT SUPPORT PADS2

3/4"=1'-0" GRAPHIC SCALE

6" 0 4'-0"1'-0" 2'-0"

NO SCALE

CONCRETE COLUMN DIAGRAM3

3/4" = 1'-0"

RETAINING WALL DETAIL5

3/4" = 1'-0"

MASONRY JOINT (MJ) DETAIL4

3/4" = 1'-0"

TYP TIE COLUMN DETAIL6 3/4" = 1'-0"

SECTION AT PRECAST COLUMN WRAP7

Sy m

De sc rip tio n Da te Ap pr ov ed

AD

DE

D

RE

BA

R

-0

7-

BK

H

FF

0' - 0"

TO STEEL

10' - 0"

13 P-AE527

074213.A04C

TO PARAPET

11' - 10"

1/2" / 12"

P-AE525

P-AE525

P-AE502

076000.U01 076000.U02

092900.B01C 054000.D06C 072713.A01

033100.A08

061000.C11

054000.D06C 076000.M04

P-AE525

054000.D04C

033100.V01

P-AE527

074213.A04C

075423.A01

FUEL PUMP

P1135

P-AE542

310000.A02 310000.C01

310000.C02

TO PANEL

36' - 10"

074213.A04C

075423.A01

SIM

11 1/4"

FF

0' - 0"

TO PRECAST

29' - 0"

TO STRUCTURE

26' - 0"

TO LOUVER

18' - 0"

074213.A04C

054000.D06C

092900.B01C

072713.A01

092900.B01C

P-AE527

P-AE503

P-AE542

033100.V01

75°

OPH

GENERATORS

P1134

310000.A02

310000.C01

310000.C02

P-F

P-AE542

076000.M04

075423.A01

051200.A06 089100.A01

P-AE542

6 SIM

FF

0' - 0"

P-C

TO PRECAST WALL

14' - 0"

034500.A03

P-AE501

TYP

H-AE504

310000.C01 19

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

3/

8"

1' -0

AM-06

P-AE312

W

AL

L S

EC

TI

ON

S

Au tho r

De sig ne r

Ch ec ke r

P-

AE

3/8" = 1'-0"

WALL SECTION 66

3/8" = 1'-0"

WALL SECTION 77

MATERIAL NOTES

033100.A08 CONCRETE CURB

033100.V01 VAPOR BARRIER

034500.A03 PRECAST CONCRETE WALL

PANEL

051200.A06 STEEL TUBE

054000.D04C STEEL STUD 4"

054000.D06C STEEL STUD 6"

061000.C11 PRESSURE TREATED WOOD

BLOCKING

072713.A01 SELF-ADHERED MEMBRANE AIR

BARRIER

074213.A04C FACTORY INSULATED WALL

PANEL 2" THICK

075423.A01 SINGLE PLY THERMOPLASTIC

ROOFING SYSTEM

076000.M04 PARAPET COPING

076000.U01 GUTTER

076000.U02 DOWNSPOUT

089100.A01 EXTRUDED ALUMINUM WALL

LOUVER

092900.B01C GYPSUM BOARD, GLASS MAT

FACED 5/8"

310000.A02 FILL MATERIAL

310000.C01 CAPILLARY WATER BARRIER

310000.C02 SAND CUSHION

1 PRECAST CONCRETE WALL BEYOND

2 R-25, UNDER ROOF PROTECTION BOARD

3 CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS

4 2" SAND CUSHION ON VAPOR BARRIER

5 4" GRAVEL

6 GENERATOR EXHAUST PIPE. EXTEND BEYOND

PRECAST PANEL

7 METAL WALL PANEL (BEYOND)

9 SEALANT AND CLOSURE PANEL BY METAL PANEL

MANUFACTURER.

10 STRUCTURAL COLUMN BEYOND

11 FLOOR TRENCH WITH COVER

12 SILL PAN WITH END DAMS

13 CONCRETE SIDEWALK

14 CONCRETE EQUIPMENT PAD

15 SEE MECHANICAL DRAWINGS FOR AIR INTAKE AND

BLANK OFF PANEL LOCATIONS.

16 16" 0C

17 GRAVEL, SEE CIVIL DRAWINGS

18 LGHT FIXTURE, SEE ELECTRICAL DRAWINGS

19 1" DIA DRAINAGE HOLES AT 8'-0" OC ALONG EAST

WALL

A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL

ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.

B. REFER TO CIVIL DRAWINGS FOR FINISH GRADE

C. PARAPET DIMENSIONS ON THIS SHEET ARE TO TOP

OF CMU OR METAL PANEL. COPING AND NAILERS

OCCUR ABOVE THIS DIMENSIONED HEIGHT.

D. COORDINATE STRUCTURAL CONNECTIONS OF

PRECAST CONCRETE PANELS WITH CMU.

CONNECTIONS VARY BY MANUFACTURER.

E. REFER TO PRECAST ELEVATIONS FOR REVEAL

LOCATIONS

F. SEE GENERAL NOTES ON P-SG001 AND P-SG002

INCLUDING NOTES ON SHALLOW FOUNDATIONS AND

OVEREXCAVATING.

3/8"=1'-0" GRAPHIC SCALE

1'01' 3' 6' 10'

3/8" = 1'-0"

WALL SECTION 88

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

O U

S

CH

AN

GE

S 1-

-1

BK

H

MI

SC

EL

LA

NE

O U

S

CH

AN

GE

S

-0 7-

BK

H

033100.A01

033100.V01

TRENCH

- 2' - 0"

BOTTOM OF

2' - 0" (NOT TO SCALE)

LEVEL 1

0' - 0"

031500.J07

055013.W21

071700.A01

051200.E01

033100.A05033100.A05

055013.W35 (36" X 36")

FF

0' - 0"

0"

1' - 0"

3'

- 0

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

042000.A01

031500.J07

071700.A01

6"

067133.A01

SIM

P-AE502

067133.A01

067133.A01

055013.W35

BO SUMP

VARIES

H-AE518

033100.G01

P-AE502

1'

- 8

067133.A01

055013.W35

3' - 0" CLEAR

093000.V01 093000.W01 220070.C01

093000.C05

093000.V01

2"

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

As in dic ate d

AM-06

P-AE502

MI

SC

EL

LA

NE

OU

S

DE

TA

ILS

Au tho r

De sig ne r

Ch ec ke r

P-

AE

1 NOT USED

2 TOP LADDER REQUIRED AT ALL FLOOR HATCH

LOCATIONS

3 WELL IS 33' DEEP UNDER PUMP HOUSE

4 NOT USED

5 RECESSED FLOOR SLAB IN BATHROOM AND

SHOWER. SEE ALSO STRUCTURAL DRAWINGS.

6 ANCHOR STRAPS BY DOOR SUPPLIER

7 WRAP WITH FILTER FABRIC AND SECURE WITH SS

WIRE

8 WITH INTEGRAL WEEPS

9 WALL BEYOND

10 SEE 2/P-AE503 FOR SHOWER VALVE (ABOVE)

DETAIL

11 CENTER LADDER INSIDE HATCH. ALIGN WITH

LADDER ABOVE.

12 SEE FINISH SCHEDULE FOR HEIGHT OF TILE

13 SLOPE FLOOR TO DRAIN

14 MUD SLAB

3" = 1'-0"

TRENCH DETAIL3

MATERIAL NOTES

031500.J07 WATERSTOP

033100.A01 CAST-IN-PLACE CONCRETE

033100.A05 CONCRETE FLOOR

033100.G01 GROUT SOLID

033100.V01 VAPOR BARRIER

042000.A01 MASONRY UNIT

051200.E01 STEEL ANGLE

055013.W21 ALUMINUM TRENCH COVER

055013.W35 ALUMINUM FLOOR HATCH

067133.A01 FRP LADDER

071700.A01 BENTONITE WATERPROOFING

SYSTEM

093000.C05 MARBLE THRESHOLD

093000.V01 WATERPROOF MEMBRANE

093000.W01 REINFORCING WIRE FABRIC

220070.C01 SHOWER FLOOR DRAIN

3" = 1'-0"

FLOOR HATCH DETAIL2

1" = 1'-0"

LADDER DETAIL4 1" = 1'-0"

LADDER PLAN DETAIL5

1'-0"0

1"=1'-0" GRAPHIC SCALE

6" 2'-0"3" 4'-0"

15"10"5"2"

3"=1'-0" GRAPHIC SCALE

01"

3" = 1'-0"

RECESSED SHOWER DETAIL6

A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL

ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.

B. DIMENSIONS ARE TO COLUMN GRID, FACE OF

MASONRY/ CONCRETE/PRECAST, FACE OF METAL

STUD

C. ALL ACT THIS BUILDING 9'-0" AFF UON.

D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING

8'-6" AFF UON.

E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND

DRAIN INSTALLATION REQUIRED ON ALL PRECAST

PANELS

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

O U

S

CH

AN

GE

S 1-

-1

BK

H

NO

TE

C

HA

NG

E

-0

7-

BK

H

075423.A01

076000.H20

075423.Q02

055013.A02

055100.R43

055013.Z02

055013.X04 8

6"

4"

072200.P02

8" M

IN

IM

UM

10072200.R02MI

N4"

" C

LE

AR

A T

SO

LA

R

PA

NE

L S

UP

PO

RT

051200.A01

076000.Z04

076000.Z04

055013.E06

220070.C31

079200.Q01

053000.A07

072200.R02

072200.P02

MI

N4"

075423.Q02

076000.Z04

076000.Z04

8" M

IN

IM

UM

075423.A01

076000.Z02

075423.Q02

079200.Q01

079200.Q01

055013.Z02

9"

072200.P024"

10072200.R02

075423.A01

075423.H11

077200.A01

" M

IN

055100.A01

053000.A07 072200.R02

077200.R01

072200.P02

079200.Q02

055013.E03

055013.E06 15

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

As in dic ate d

AM-06

P-AE522

RO

OF

D

ET

AI

LS

Au tho r

De sig ne r

Ch ec ke r

P-

AE

1 SEE 3/P-SF505 FOR CONNECTIONS

2 3" DIA., GALVANIZED

3 ROLL PIPE FLASHING OVER TOP & FOLD DOWN INTO

PIPE EVENLY.

4 6" MIN. METAL FLANGE SET IN COMPATIBLE FULL

BED OF ROOFING SEALANT OVER BASE PLY (LAP

CAP SHEET OVER FLANGE).

5 FACTORY MOLDED PIPE BOOT FLASHING

6 REFER TO ELECTRICAL DOCUMENTS FOR CONDUIT

MOUNTING CONDITIONS AND LOCATIONS TYP.

7 CIRCULAR PLATE WELD TO PIPE TOP & GRIND

EDGES SMOOTH.

8 STAINLESS STEEL.

10 R-25 MINIMUM, CONTINUOUS

11 DRAW BAND

12 ONLY REQUIRED AT ROOF FLUE DETAIL 2/P-AE523

13 SEALANT ALL AROUND

14 4'-0" X 4'-0" ROOF SCUTTLE, TYPICAL.

15 CONTINUOUS PLATE SURROUND 3/16"X5" HIGH

16 ANGLE FRAME SURROUNDS OPENING. SEE

STRUCTURAL DRAIWNGS.

17 SEE 6/H-AE546 FOR AXONOMETRIC VIEW

MATERIAL NOTES

051200.A01 STEEL BEAM

053000.A07 STEEL ROOF DECK

055013.A02 STEEL PIPE

055013.E03 CONTINUOUS STEEL ANGLE

055013.E06 STEEL PLATE

055013.X04 GUY CABLES

055013.Z02 STAINLESS STEEL EYEHOOK

055100.A01 STEEL STAIR

055100.R43 PLATE CLOSURE, WELD AND

GRIND SMOOTH

072200.P02 GLASS MAT GYPSUM

PROTECTION BOARD

072200.R02 ROOF INSULATION BOARD

075423.A01 SINGLE PLY THERMOPLASTIC

ROOFING SYSTEM

075423.H11 THERMOPLASTIC BASE

FLASHING

075423.Q02 MASTIC SEALANT

076000.H20 PIPE FLASHING

076000.Z02 SHEET METAL COLLAR

076000.Z04 CLAMPING RING

077200.A01 ROOF HATCH

077200.R01 ROOF ACCESS RAILING SYSTEM

079200.Q01 JOINT SEALANT

079200.Q02 BACKSTOP AND SEALANT

220070.C31 VENT PIPING

15"10"5"2"

3"=1'-0" GRAPHIC SCALE

01"

30"20"10"2"0

1 1/2"=1'-0" GRAPHIC SCALE

2"

3" = 1'-0"

EQUIPMENT SUPPORT / TIE DOWN/

PANELSUPPORT1

3" = 1'-0"

PLUMBING PIPE PENETRATION2

3" = 1'-0"

SMALL PIPE PENETRATION3 1 1/2" = 1'-0"

ROOF ACCESS HATCH5

A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL

ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.

B. DIMENSIONS ARE TO COLUMN GRID, FACE OF

MASONRY/ CONCRETE/PRECAST, FACE OF METAL

STUD

C. ALL ACT THIS BUILDING 9'-0" AFF UON.

D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING

8'-6" AFF UON.

E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND

DRAIN INSTALLATION REQUIRED ON ALL PRECAST

PANELS

Sy m

De sc rip tio n Da te Ap pr ov ed

MI

SC

EL

LA

NE

O U

S

CH

AN

GE

S

-0 7-

BK

H

M

WATER TREAT

P1102

GAS

P1103

GAS

P1104

P-1P-3

P-A

P-B

P-2

FS-1

FS-1

FS-1

FD-3

FD-3

FS-1

6"

6"

LP

LP

FS-1

FS-1

FCO

6"

6"

3"

3"

4"

3/4" 3/4" 1/2"

EW-2

RO

1.1

RO

1.2

2 1/2"

2"

1 1/4"

EW-2

PP6220

PP6220

PP6022

ETP

P1.1

6"

6"

CF

1.1

CF

1.2

CF

1.3

6" 6"

1/2" 1/2"

1/2"

3/4"

LP

R O

RO

R O

R O

RO

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1/

4"

1' -0

AM-06

P-PP4001

EN

LA

RG

ED

P

LA

NS

PL

UM

BI

NG

AL

B

TC

C

MJ

T

P-

PP

1/4" = 1'-0"

ENLARGED PLANS - PLUMBING1

1 WATER TREATMENT FUTURE BYPASS.

2 36" x 36" x 24" BLOWDOWN/BACKWASH SUMP.

3 LP EMERGENCY CONNECTION. PROVIDE DOUBLE

CHECK FILLER VALVE.

4 CHEMICAL INJECTION PIPING. REFER TO DIVISION

22 SPECIFICATIONS.

5 MEDICAL GAS EQUIPMENT.

6 CHILLER.

7 HVAC PUMP PACKAGE.

8 3/4"SHW UP TO SOLAR ARRAY.

9 LP METER CAPABLE OF READING 19,000 MBTUH.

10 LP REGULATOR. INLET PRESSURE = 10 PSIG,

OUTLET PRESSURE = 2 PSIG, FLOW = 7,200 CFH.

A REFER TO PP5000 SERIES SHEETS FOR

DETAILS, PP6000 SERIES SHEETS FOR RISER

DIAGRAMS, PP7000 SERIES SHEETS FOR

SEQUENCES, AND PP8000 SERIES SHEETS FOR

SCHEDULES.

N

1/4"=1'-0" GRAPHIC SCALE

15'10'5'1'01'

KEY PLAN

P

Sy m

De sc rip tio n Da te Ap pr ov ed

RE

VI

SE

D

PI

PI

N G

-0 7-

BK

H

RC-16 FOOTING SIZES SHOWN ARE FOR FOOTINGS CONSTRUCTED WITH

SIDE FORMS. IF SOIL MATERIAL CAN HOLD A VERTICAL SHAPE, THE

SOIL CAN BE USED AS AN EARTH FORM PROVIDED OVERALL

FOOTING WIDTH IS INCREASED 4", AND CODE COVER INCREASED

BY 2”. ALL SLOUGHED MATERIAL SHALL BE REMOVED FROM

EXCAVATION BEFORE AND DURING PLACEMENT OF CONCRETE.

RC-17 USE THE STRUCTURAL DRAWINGS, INCLUDING REVISIONS AND

ADDENDA, IN CONJUNCTION WITH REVIEWED SHOP DRAWINGS

FOR PLACEMENT OF REINFORCING.

RC-18 SLEEVE ALL PENETRATIONS THROUGH BEAMS AND SLABS

INDIVIDUALLY. CORE DRILLING SHALL NOT BE PERMITTED. SUBMIT

LOCATION AND SIZE OF SLEEVES THROUGH BEAMS TO

CONTRACTING OFFICER FOR REVIEW PRIOR TO CASTING

CONCRETE.

RC-19 NO REINFORCING BARS SHALL BE CUT TO ACCOMMODATE THE

INSTALLATION OF ANCHORS, EMBEDS OR OTHER ITEMS.

RC-20 ALL EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE PRIOR

TO CONCRETE PLACEMENT.

RC-21 PLACEMENT OF CONDUIT AND PIPES IN CONCRETE SHALL

CONFORM TO ACI 318 (6.3).

RC-22 PLACE CONCRETE PER ACI 304. USE INTERNAL MECHANICAL

VIBRATION FOR ALL CONCRETE. LIMIT MAXIMUM FREE FALL DROP

OF COLUMN OR WALL CONCRETE TO 6'-0". IN SLABS, BEAMS,

FOOTINGS, ETC., LIMIT FREE FALL DROP TO 3'-0". ALL

PRECAUTIONS SHOULD BE TAKEN TO AVOID SEGREGATION OF

CONCRETE DURING PLACEMENT.

RC-23 WEDGE BOLTS SHALL CONFORM TO THE REQUIREMENTS OF THE

LATEST ACI 355.2 AND PROVIDE THE FOLLOWING ALLOWABLE

LOADS FOR 4-3/4" EMBEDMENT DEPTH IN 4000 PSI CONCRETE:

TENSION 5.2K, SHEAR 5.4K. INSTALLATION SHALL BE BY QUALIFIED

RC-24 ADHESIVE ANCHORS SHALL CONFORM TO THE LATEST ACI 355.4

AND PROVIDE THE FOLLOWING MINIMUM STRENGTHS FOR 3/4" DIA

A307 THREADED ROD: CRACKED CONCRETE BOND STRENGTH OF 710

PSI. INSTALLATION SHALL BE BY QUALIFIED PERSONNEL AND

INSTALLATION SHALL BE IN ACCORDANCE WITH THE

RC-25 HEADED STUD ANCHORS AND STUD WELDING SHALL CONFORM

TO AWS D1.1 “STRUCTURAL WELDING CODE”, TYPE B MADE FROM

ASTM A108, AND HAVE A MINIMUM TENSILE STRENGTH OF 65KSI.

RC-2 STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301

SPECIFICATIONS AND SHALL DEVELOP THE FOLLOWING

MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS:

FOOTINGS 4,000 PSI (TYPE II OR TYPE V CEMENT)

COLUMNS AND WALLS 4,000 PSI

BEAMS AND SLABS 4,000 PSI

RETAINING WALLS 4,000 PSI (TYPE II OR TYPE V CEMENT)

ALL OTHER CONCRETE 4,000 PSI

RC-3 USE REGULAR WEIGHT CONCRETE. SUBMIT DESIGN MIX FOR

REVIEW PRIOR TO PLACEMENT OF CONCRETE. ALL MIX DESIGNS

MUST CLEARLY INDICATE INTENDED USE AND LOCATION. MIXES

RC-4 STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 AND HAVE

THE FOLLOWING SLUMPS & AGGREGATE REQUIREMENTS:

LOCATION SLUMP MAX. AGGREGATE

FOUNDATIONS, WALLS, 2" ± 1" ASTM #67

FOOTINGS AND SLABS

RC-5 FLYASH, WHEN USED, SHALL BE NOT LESS THAN 20 PERCENT OR

MORE THAN 35 PERCENT BY WEIGHT OF THE TOTAL CEMENTITIOUS

RC-6 ALL PUMPED CONCRETE WITH #67 AGGREGATE IS TO CONTAIN A

HIGH RANGE WATER REDUCING AGENT. MINIMUM SIZE OF

DISCHARGE TO BE 4" I.D.

RC-7 CHAMFER ALL EDGES OF EXPOSED CONCRETE 3/4" UNLESS

NOTED OTHERWISE.

RC-8 ALL REINFORCING STEEL SHALL BE DETAILED, FABRICATED AND

INSTALLED IN ACCORDANCE WITH ACI 318 AND ACI DETAILING

MANUAL, ACI-315 MOST CURRENT EDITIONS.

RC-9 REINFORCING STEEL SHALL BE NEW DEFORMED BARS THAT ARE

FREE FROM RUST, SCALE AND OIL AND CONFORM TO ASTM A615,

GRADE 60, WITH MINIMUM YIELD STRENGTH = 60,000 PSI.

RC-10 SHOP DRAWINGS FOR PLACEMENT SHALL BE SUBMITTED FOR

REVIEW PRIOR TO REBAR FABRICATION.

RC-11 WELDED WIRE FABRIC SHALL CONFORM TO ASTM-A185.

RC-12 LAP CONTINUOUS REINFORCING AS NOTED IN THE LAP SPLICE

SCHEDULE. LAP CONT. BOTTOM STEEL OVER SUPPORT AND CONT.

TOP STEEL AT MIDSPAN UNLESS OTHERWISE SPECIFIED.

RC-13 TERMINATE ALL DISCONTINUOUS TOP BARS WITH STANDARD 90

DEGREE HOOK (PLACED VERTICALLY) UNLESS NOTED

OTHERWISE.

RC-14 AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS & STRIP

FOOTINGS, PROVIDE CORNER BARS OF SAME SIZE AND QUANTITY

(U.N.O.) AS HORIZONTAL STEEL. REFER TO TYPICAL DETAIL.

RC-15 PROVIDE THE FOLLOWING CONCRETE COVERAGES OVER

REINFORCING (U.N.O.):

FOOTINGS: BOTTOM AND SIDES 3" CLR.

TOP 2” CLR.

BEAMS & COLUMNS (TO TIES): INTERIOR 1 1/2" CLR.

SLABS: (TOP AND BOTTOM STEEL)

INTERIOR 3/4" CLR.

EXTERIOR…