Drwgs_Vol_5A_50shts_W912PL-12-R-0008.pdf
PDF 19 MB Posted
- Solicitation number
- W912PL-12-R-0008
About this file
Drawings - Volume 5A
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet Reference Number
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
FORT IRWIN HOSPITAL REPLACEMENT
FORT IRWIN, CALIFORNIA
A pp ro ve d:
P re pa re d U nd er th e
D ire ct io n of
C hi ef , E ng in ee rin g D iv is io n:
D at e:
C ol
. C or ps o f E ng in ee rs
D is tri ct
E ng in ee r
D
EC
EM
BE
R, Los Angeles District
8-
-0
RO
N
W . L
OW
RYRON W. LOWRY
RLF/AECOM
ARCHITECT
C.ALLAN BAMFORTH, JR.
ENGINEER - SURVEYOR, LTD.
CIVIL
DEBORAH MONTEFERRANTE
MAI LANDSCAPE ARCHITECTS
LANDSCAPE ARCHITECT
STEVEN L. SHELT
ALLAN AND CONRAD, INC.
STRUCTURAL ENGINEER
LAWRENCE P. LAMMERS
LAMMERS & ASSOCIATES
MATERIALS MANAGEMENT
AND AUTO. TRANSPORTATION
BARRY EARL FIEDLER
RLF/AECOM
MECHANICAL
KENDALL LEE MASON
RLF/AECOM
ELECTRICAL
BUFORD M. LOVETT
LOVETT CONSULTANTS
FIRE PROTECTION
RICHARD E. GARRIOTT
R
IC
K
PO
EP
PE
LM
AN
W
IL
LI
AM
J . L
EA
D
Y
BARRY EARL FIEDLER
RLF/AECOM
PLUMBING
I52 1-
GI000.5
CO
VE
R
SH
EE
T
PK
L
GT
S
PA
W
VO
LU
ME
GI
0.5
PN_NO: 70354
FY_NO: 2012
VOLUME 5
BID DOCUMENTS
DECEMBER 02, 2011
Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
GI005.1
IN
DE
X
OF
D
RA
W
IN
GS
PK
L
De sig ne r
BK
H
VO
LU
ME
GI
5.1
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
HOSPITAL / CLINIC - CONT:
MECHANICAL
VOLUME 5 MECHANICAL - CONT.
ENLARGED PLANS
H-MH4001 HVAC DUCTWORK ENLARGED PLAN 1210
H-MH4002 HVAC DUCTWORK ENLARGED PLAN 1211
H-MH4003 HVAC DUCTWORK ENLARGED PLAN 1212
H-MH4004 HVAC DUCTWORK ENLARGED PLAN 1213
H-MH4005 HVAC DUCTWORK ENLARGED PLAN 1214
H-MH4006 HVAC DUCTWORK ENLARGED PLAN 1215
H-MH4007 HVAC DUCTWORK ENLARGED PLAN 1216
H-MH4008 HVAC DUCTWORK ENLARGED PLAN 1217
H-MH4009 HVAC DUCTWORK ENLARGED PLAN 1218
H-MH4010 HVAC DUCTWORK ENLARGED PLAN 1219
H-MH4011 ENLARGED SHAFT PLANS 1220
H-MH4012 ENLARGED SHAFT PLANS 1221
H-MH4013 ENLARGED SHAFT PLANS 1222
H-MH4014 ENLARGED SHAFT PLANS 1223
H-MH4015 ENLARGED SHAFT PLANS 1224
H-MH4016 ENLARGED SHAFT PLANS 1225
H-MH4017 SECTIONS 1226
H-MH4018 SECTIONS 1227
H-MH4019 SECTIONS 1228
H-MH4020 SECTIONS 1229
H-MH4021 SECTIONS 1230
H-MH4022 SECTIONS 1231
H-MH4023 SECTIONS 1232
H-MH4024 SECTIONS 1233
H-MH4025 SECTIONS 1234
H-MH4026 SECTIONS 1235
H-MH4027 SECTIONS 1236
H-MH4028 SECTIONS 1237
H-MH4029 SECTIONS 1238
H-MH4030 SECTIONS 1239
H-MH4031 SECTIONS 1240
H-MH4032 SECTIONS 1241
H-MH4033 SECTIONS 1242
H-MH4034 SECTIONS 1243
H-MH4035 SECTIONS 1244
H-MH4036 SECTIONS 1245
H-MH4037 SECTIONS 1246
H-MH4038 SECTIONS 1248
H-MH4039 SECTIONS 1247
H-MH4040 SECTIONS 1249
H-MH4041 SECTIONS 1250
H-MH4042 SECTIONS 1251
H-MH4043 SECTIONS 1252
H-MH4044 SECTIONS 1253
H-MH4045 SECTIONS 1254
H-MH4046 SECTIONS 1255
H-MH4047 AHU COMPONENT LAYOUTS 1256
H-MH4048 AHU COMPONENT LAYOUTS 1257
H-MH4049 AHU COMPONENT LAYOUTS 1258
H-MH4050 AHU COMPONENT LAYOUTS 1259
H-MP4001 HVAC PIPING ENLARGED PLAN 1260
H-MP4002 HVAC PIPING ENLARGED PLAN 1261
H-MP4003 HVAC PIPING ENLARGED PLAN 1262
H-MP4004 HVAC PIPING ENLARGED PLAN 1263
H-MP4005 HVAC PIPING ENLARGED PLAN 1264
H-MP4006 HVAC PIPING ENLARGED PLAN 1265
H-MP4007 HVAC PIPING ENLARGED PLAN 1266
SYMBOLS AND ABBREVIATIONS
MH001 MECHANICAL SYMBOLS AND ABBREVIATIONS 1170
MH002 MECHANICAL SYMBOLS AND ABBREVIATIONS 1171
SHEET NOTES
MH003 MECHANICAL TYPICAL SHEET NOTES 1172
MH004 MECHANICAL TYPICAL SHEET NOTES 1173
AHU ZONING PLAN
MH1AB AHU ZONING PLANS 1174
HVAC PLAN
H-MH1011 LEVEL 1, ZONE 1 - HVAC DUCTWORK PLAN 1175
H-MH1012 LEVEL 1, ZONE 2 - HVAC DUCTWORK PLAN 1176
H-MH1013 LEVEL 1, ZONE 3 - HVAC DUCTWORK PLAN 1177
H-MH1014 LEVEL 1, ZONE 4 - HVAC DUCTWORK PLAN 1178
H-MH1015 LEVEL 1, ZONE 5 - HVAC DUCTWORK PLAN 1179
H-MH1021 LEVEL 2, ZONE 1 - HVAC DUCTWORK PLAN 1180
H-MH1022 LEVEL 2, ZONE 2 - HVAC DUCTWORK PLAN 1181
H-MH1023 LEVEL 2, ZONE 3 - HVAC DUCTWORK PLAN 1182
H-MH1024 LEVEL 2, ZONE 4 - HVAC DUCTWORK PLAN 1183
H-MH1025 LEVEL 2, ZONE 5 - HVAC DUCTWORK PLAN 1184
H-MH1031 LEVEL 3, ZONE 1 - HVAC DUCTWORK PLAN 1185
H-MH1032 LEVEL 3, ZONE 2 - HVAC DUCTWORK PLAN 1186
H-MH1033 LEVEL 3, ZONE 3 - HVAC DUCTWORK PLAN 1187
H-MH1034 LEVEL 3, ZONE 4 - HVAC DUCTWORK PLAN 1188
H-MH1035 LEVEL 3, ZONE 5 - HVAC DUCTWORK PLAN 1189
H-MH1051 LEVEL 5, ZONE 1 - PENTHOUSE ROOF PLAN 1190
HVAC PLAN
H-MH104A LEVEL 4, ZONE A - HVAC DUCTWORK PLAN 1191
H-MH104B LEVEL 4, ZONE B - HVAC DUCTWORK PLAN 1192
PIPING PLAN
H-MP1011 LEVEL 1, ZONE 1 - HVAC PIPING PLAN 1193
H-MP1012 LEVEL 1, ZONE 2 - HVAC PIPING PLAN 1194
H-MP1013 LEVEL 1, ZONE 3 - HVAC PIPING PLAN 1195
H-MP1014 LEVEL 1, ZONE 4 - HVAC PIPING PLAN 1196
H-MP1015 LEVEL 1, ZONE 5 - HVAC PIPING PLAN 1197
H-MP1021 LEVEL 2, ZONE 1 - HVAC PIPING PLAN 1198
H-MP1022 LEVEL 2, ZONE 2 - HVAC PIPING PLAN 1199
H-MP1023 LEVEL 2, ZONE 3 - HVAC PIPING PLAN 1200
H-MP1024 LEVEL 2, ZONE 4 - HVAC PIPING PLAN 1201
H-MP1025 LEVEL 2, ZONE 5 - HVAC PIPING PLAN 1202
H-MP1031 LEVEL 3, ZONE 1 - HVAC PIPING PLAN 1203
H-MP1032 LEVEL 3, ZONE 2 - HVAC PIPING PLAN 1204
H-MP1033 LEVEL 3, ZONE 3 - HVAC PIPING PLAN 1205
H-MP1034 LEVEL 3, ZONE 4 - HVAC PIPING PLAN 1206
H-MP1035 LEVEL 3, ZONE 5 - HVAC PIPING PLAN 1207
PIPING PLAN
H-MP104A LEVEL 4, ZONE A - HVAC PIPING PLAN 1208
H-MP104B LEVEL 4, ZONE B - HVAC PIPING PLAN 1209
GENERAL
GI000.5 COVER SHEET VOLUME 5 1169
GI005.1 INDEX OF DRAWINGS VOLUME 5 15
GI005.2 INDEX OF DRAWINGS VOLUME 5 CONT. 16
GI005.3 INDEX OF DRAWINGS VOLUME 5 CONT. 17
GI005.4 INDEX OF DRAWINGS VOLUME 5 CONT. 18
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
GI005.2
IN
DE
X
OF
D
RA
W
IN
GS
PK
L
De sig ne r
BK
H
VO
LU
ME
CO
NT
GI
5.2
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
VOLUME 5 CONT.
HOSPITAL / CLINIC - CONT:
MECHANICAL CONT.
MI7025 SCHEMATIC CONTROL DIAGRAMS 1329
MI7026 CONTROL SEQUENCES 1330
MI7027 CONTROL SEQUENCES 1331
MI7028 CONTROL SEQUENCES 1332
MI7029 SCHEMATIC CONTROL DIAGRAMS 1333
MI7030 SCHEMATIC CONTROL DIAGRAMS 1334
MI7031 CONTROL SEQUENCES 1335
MI7032 CONTROL SEQUENCES 1336
MI7033 CONTROL SEQUENCES 1337
MI7034 SCHEMATIC CONTROL DIAGRAMS 1338
MI7035 SCHEMATIC CONTROL DIAGRAMS 1339
MI7036 CONTROL SEQUENCES 1340
MI7037 CONTROL SEQUENCES 1341
MI7038 CONTROL SEQUENCES 1342
MI7039 SCHEMATIC CONTROL DIAGRAMS 1343
MI7040 CONTROL SEQUENCES 1344
MI7041 CONTROL SEQUENCES 1345
MI7042 SCHEMATIC CONTROL DIAGRAMS 1346
MI7043 SCHEMATIC CONTROL DIAGRAMS 1347
MI7044 CONTROL SEQUENCES 1348
MI7045 SCHEMATIC CONTROL DIAGRAMS AND SEQUENCES 1349
MI7046 SCHEMATIC CONTROL DIAGRAMS 1350
MI7047 SCHEMATIC CONTROL DIAGRAMS 1351
MI7048 CONTROL SEQUENCES 1352
MI7049 SCHEMATIC CONTROL DIAGRAMS 1353
MI7050 CONTROL SEQUENCES 1354
MI7051 SCHEMATIC CONTROL DIAGRAMS 1355
MI7052 CONTROL SEQUENCES 1356
MI7053 SCHEMATIC CONTROL DIAGRAMS 1357
MI7054 CONTROL SEQUENCES 1358
MI7055 SCHEMATIC CONTROL DIAGRAMS AND SEQUENCES 1359
MI7056 SCHEMATIC CONTROL DIAGRAMS AND SEQUENCES 1360
MI7057 SCHEMATIC CONTROL DIAGRAMS 1361
MI7058 SCHEMATIC CONTROL DIAGRAMS 1362
MI7059 CONTROL SEQUENCES 1363
MI7060 SCHEMATIC CONTROL DIAGRAMS AND SEQUENCES 1364
MI7061 SCHEMATIC CONTROL DIAGRAMS AND SEQUENCES 1365
MI7062 SCHEMATIC CONTROL DIAGRAMS AND SEQUENCES 1366
MI7063 SCHEMATIC CONTROL DIAGRAMS AND SEQUENCES 1367
MI7064 SCHEMATIC CONTROL DIAGRAMS 1368
MI7065 CONTROL SEQUENCES 1369
MI7066 SCHEMATIC CONTROL DIAGRAMS 1370
MI7067 CONTROL SEQUENCES 1371
MI7068 CONTROL TRENDING AND ALARMS 1372
MI7069 CONTROL TRENDING AND ALARMS 1373
MI7070 CONTROL TRENDING AND ALARMS 1374
MI7071 CONTROL TRENDING AND ALARMS 1375
MECHANICAL SCHEDULES
MH8001 MECHANICAL SCHEDULES 1376
MH8002 MECHANICAL SCHEDULES 1377
MH8003 MECHANICAL SCHEDULES 1378
MH8004 MECHANICAL SCHEDULES 1379
MH8005 MECHANICAL SCHEDULES 1380
MH8006 MECHANICAL SCHEDULES 1381
MH8007 MECHANICAL SCHEDULES 1382
MH8008 MECHANICAL SCHEDULES 1383
MH8009 MECHANICAL SCHEDULES 1384
MH8010 MECHANICAL SCHEDULES 1385
MH8011 MECHANICAL SCHEDULES 1386
MH8012 MECHANICAL SCHEDULES 1387
MH8013 MECHANICAL SCHEDULES 1388
MH8014 MECHANICAL SCHEDULES 1389
MH8015 MECHANICAL SCHEDULES 1390
MH8016 MECHANICAL SCHEDULES 1391
MH8017 MECHANICAL SCHEDULES 1392
MH8018 MECHANICAL SCHEDULES 1393
MH8019 MECHANICAL SCHEDULES 1394
MH8020 MECHANICAL SCHEDULES 1395
DETAILS
MH5001 HVAC DETAILS 1267
MH5002 HVAC DETAILS 1268
MH5003 HVAC DETAILS 1269
MH5004 HVAC DETAILS 1270
MH5005 HVAC DETAILS 1271
MH5006 HVAC DETAILS 1272
MH5007 HVAC DETAILS 1273
MH5008 HVAC DETAILS 1274
MH5009 HVAC DETAILS 1275
MH5010 HVAC DETAILS 1276
MP5001 HVAC PIPING DETAILS 1277
MP5002 HVAC PIPING DETAILS 1278
MP5003 HVAC PIPING DETAILS 1279
MP5004 HVAC PIPING DETAILS 1280
MP5005 HVAC PIPING DETAILS 1281
MP5006 HVAC PIPING DETAILS 1282
MP5007 HVAC PIPING DETAILS 1283
MP5008 HVAC PIPING DETAILS 1284
MP5009 HVAC PIPING DETAILS 1285
MP5010 HVAC PIPING DETAILS 1286
MP5011 HVAC PIPING DETAILS 1287
MP5012 HVAC PIPING DETAILS 1288
MP5013 HVAC PIPING DETAILS 1289
MP5014 HVAC PIPING DETAILS 1290
MP5015 HVAC PIPING DETAILS 1291
SCHEMATIC FLOW DIAGRAM
MH6001 SCHEMATIC FLOW DIAGRAM - DUCTWORK 1292
MH6002 SCHEMATIC FLOW DIAGRAM - DUCTWORK 1293
MH6003 SCHEMATIC FLOW DIAGRAM - DUCTWORK 1294
MH6004 SCHEMATIC FLOW DIAGRAM - DUCTWORK 1295
MP6001 SCHEMATIC FLOW DIAGRAM - CHILLED/CONDENSER WATER 1296
MP6002 SCHEMATIC FLOW DIAGRAM - CHILLED WATER 1297
MP6003 SCHEMATIC FLOW DIAGRAM - CHILLED WATER 1298
MP6004 SCHEMATIC FLOW DIAGRAM - HEATING WATER 1299
MP6005 SCHEMATIC FLOW DIAGRAM - HEATING WATER 1300
MP6006 SCHEMATIC FLOW DIAGRAM - HEATING WATER 1301
MP6007 SCHEMATIC FLOW DIAGRAM - GENERATOR FUEL OIL SYSTEM 1302
MP6008 SCHEMATIC FLOW DIAGRAM - BOILER BURNER GAS TRAIN 1303
CONTROLS
MI7000 CONTROLS SYSTEMS LEGEND 1304
MI7001 DDC SYSTEM ARCHITECTURE 1305
MI7002 DDC SYSTEM ARCHITECTURE 1306
MI7003 DDC SYSTEM ARCHITECTURE 1307
MI7004 SCHEMATIC CONTROL DIAGRAMS 1308
MI7005 SCHEMATIC CONTROL DIAGRAMS 1309
MI7006 SCHEMATIC CONTROL DIAGRAMS 1310
MI7007 CONTROL SEQUENCES 1311
MI7008 CONTROL SEQUENCES 1312
MI7009 SCHEMATIC CONTROL DIAGRAMS 1313
MI7010 SCHEMATIC CONTROL DIAGRAMS 1314
MI7011 SCHEMATIC CONTROL DIAGRAMS 1315
MI7012 CONTROL SEQUENCES 1316
MI7013 SCHEMATIC CONTROL DIAGRAMS 1317
MI7014 SCHEMATIC CONTROL DIAGRAMS 1318
MI7015 SCHEMATIC CONTROL DIAGRAMS 1319
MI7016 SCHEMATIC CONTROL DIAGRAMS 1320
MI7017 CONTROL SEQUENCES 1321
MI7018 SCHEMATIC CONTROL DIAGRAMS 1322
MI7019 SCHEMATIC CONTROL DIAGRAMS 1323
MI7020 CONTROL SEQUENCES 1324
MI7021 CONTROL SEQUENCES 1325
MI7022 CONTROL SEQUENCES 1326
MI7023 CONTROL SEQUENCES 1327
MI7024 SCHEMATIC CONTROL DIAGRAMS 1328
CONTROLS - CONT:
SY
M
D
ES
C R
IP
TI
O N
D
Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
GI005.3
IN
DE
X
OF
D
RA
W
IN
GS
PK
L
De sig ne r
BK
H
VO
LU
ME
CO
NT
GI
5.3
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
HOSPITAL / CLINIC - CONT:
PLUMBING
VOLUME 5 CONT.
PP5009 PLUMBING DETAILS 1457
PP5010 PLUMBING DETAILS 1458
PP5011 PLUMBING DETAILS 1459
PP5012 PLUMBING DETAILS 1460
PP5013 PLUMBING DETAILS 1461
PP5014 PLUMBING DETAILS 1462
PP5015 PLUMBING DETAILS 1463
PP5101 MEDICAL GAS DETAILS 1464
PP5102 MEDICAL GAS DETAILS 1465
PP5103 MEDICAL GAS DETAILS 1466
PP5104 MEDICAL GAS DETAILS 1467
RISER DIAGRAMS
PP6001 SANITARY RISER DIAGRAMS 1468
PP6002 SANITARY RISER DIAGRAMS 1469
PP6003 SANITARY RISER DIAGRAMS 1470
PP6004 SANITARY RISER DIAGRAMS 1471
PP6005 SANITARY RISER DIAGRAMS 1472
PP6006 SANITARY RISER DIAGRAMS 1473
PP6007 SANITARY RISER DIAGRAMS 1474
PP6008 SANITARY RISER DIAGRAMS 1475
PP6009 SANITARY RISER DIAGRAMS 1476
PP6010 SANITARY RISER DIAGRAMS 1477
PP6011 SANITARY RISER DIAGRAMS 1478
PP6012 SANITARY RISER DIAGRAMS 1479
PP6013 SANITARY RISER DIAGRAMS 1480
PP6014 SANITARY RISER DIAGRAMS 1481
PP6015 SANITARY RISER DIAGRAMS 1482
PP6016 SANITARY RISER DIAGRAMS 1483
PP6017 SANITARY RISER DIAGRAMS 1484
PP6018 SANITARY RISER DIAGRAMS 1485
PP6019 SANITARY RISER DIAGRAMS 1486
PP6020 SANITARY RISER DIAGRAMS 1487
PP6021 SANITARY RISER DIAGRAMS 1488
PP6022 SANITARY RISER DIAGRAMS 1489
PP6023 SANITARY RISER DIAGRAMS 1490
PP6024 SANITARY RISER DIAGRAMS 1491
RISER DIAGRAMS
PP6101 RAINWATER RISER DIAGRAMS 1492
PP6102 RAINWATER RISER DIAGRAMS 1493
PP6103 RAINWATER RISER DIAGRAMS 1494
RISER DIAGRAMS
PP6201 DOMESTIC WATER RISER DIAGRAMS 1495
PP6202 DOMESTIC WATER RISER DIAGRAMS 1496
PP6203 DOMESTIC WATER RISER DIAGRAMS 1497
PP6204 DOMESTIC WATER RISER DIAGRAMS 1498
PP6205 DOMESTIC WATER RISER DIAGRAMS 1499
PP6206 DOMESTIC WATER RISER DIAGRAMS 1500
PP6207 DOMESTIC WATER RISER DIAGRAMS 1501
PP6208 DOMESTIC WATER RISER DIAGRAMS 1502
PP6209 DOMESTIC WATER RISER DIAGRAMS 1503
PP6210 DOMESTIC WATER RISER DIAGRAMS 1504
PP6211 DOMESTIC WATER RISER DIAGRAMS 1505
PP6212 DOMESTIC WATER RISER DIAGRAMS 1506
PP6213 DOMESTIC WATER RISER DIAGRAMS 1507
PP6214 DOMESTIC WATER RISER DIAGRAMS 1508
PP6215 DOMESTIC WATER RISER DIAGRAMS 1509
PP6216 DOMESTIC WATER RISER DIAGRAMS 1510
PP6217 DOMESTIC WATER RISER DIAGRAMS 1511
PP6218 DOMESTIC WATER RISER DIAGRAMS 1512
PP6219 DOMESTIC WATER RISER DIAGRAMS 1513
PP6220 DOMESTIC WATER RISER DIAGRAMS 1514
PP6221 DOMESTIC WATER RISER DIAGRAMS 1515
PP6222 DOMESTIC WATER RISER DIAGRAMS 1516
PP6223 DOMESTIC WATER RISER DIAGRAMS 1517
GENERAL
H-PP0001 PLUMBING SYMBOLS AND ABBREVIATIONS 1396
H-PP0002 PLUMBING SYMBOLS AND ABBREVIATIONS 1397
PLUMBING SITE PLANS
H-PS1001 PLUMBING SITE PLANS 1398
H-PS1002 PLUMBING SITE PLANS 1399
PLUMBING FLOOR PLANS
H-PP1001 BELOW SLAB, ZONE 1 - PLUMBING PLAN 1400
H-PP1002 BELOW SLAB, ZONE 2 - PLUMBING PLAN 1401
H-PP1003 BELOW SLAB, ZONE 3 - PLUMBING PLAN 1402
H-PP1004 BELOW SLAB, ZONE 4 - PLUMBING PLAN 1403
H-PP1005 BELOW SLAB, ZONE 5 - PLUMBING PLAN 1404
H-PP1011 LEVEL 1, ZONE 1 - PLUMBING PLAN 1405
H-PP1012 LEVEL 1, ZONE 2 - PLUMBING PLAN 1406
H-PP1013 LEVEL 1, ZONE 3 - PLUMBING PLAN 1407
H-PP1014 LEVEL 1, ZONE 4 - PLUMBING PLAN 1408
H-PP1015 LEVEL 1, ZONE 5 - PLUMBING PLAN 1409
H-PP1021 LEVEL 2, ZONE 1 - PLUMBING PLAN 1410
H-PP1022 LEVEL 2, ZONE 2 - PLUMBING PLAN 1411
H-PP1023 LEVEL 2, ZONE 3 - PLUMBING PLAN 1412
H-PP1024 LEVEL 2, ZONE 4 - PLUMBING PLAN 1413
H-PP1025 LEVEL 2, ZONE 5 - PLUMBING PLAN 1414
H-PP1031 LEVEL 3, ZONE 1 - PLUMBING PLAN 1415
H-PP1032 LEVEL 3, ZONE 2 - PLUMBING PLAN 1416
H-PP1033 LEVEL 3, ZONE 3 - PLUMBING PLAN 1417
H-PP1034 LEVEL 3, ZONE 4 - PLUMBING PLAN 1418
H-PP1035 LEVEL 3, ZONE 5 - PLUMBING PLAN 1419
H-PP1041 LEVEL 4, ZONE 1 - PLUMBING PLAN 1420
H-PP1042 LEVEL 4, ZONE 2 - PLUMBING PLAN 1421
H-PP1043 LEVEL 4, ZONE 3 - PLUMBING PLAN 1422
H-PP1044 LEVEL 4, ZONE 4 - PLUMBING PLAN 1423
H-PP1045 LEVEL 4, ZONE 5 - PLUMBING ROOF PLAN 1424
H-PP1051 LEVEL 5, ZONE 1 - PLUMBING ROOF PLAN 1425
H-PP1052 LEVEL 5, ZONE 2 - PLUMBING ROOF PLAN 1426
H-PP1053 LEVEL 5, ZONE 3 - PLUMBING ROOF PLAN 1427
H-PP1054 LEVEL 5, ZONE 4 - PLUMBING ROOF PLAN 1428
MEDICAL GAS FLOOR PLANS
H-PP1111 LEVEL 1, ZONE 1 - MEDICAL GAS PLAN 1429
H-PP1112 LEVEL 1, ZONE 2 - MEDICAL GAS PLAN 1430
H-PP1113 LEVEL 1, ZONE 3 - MEDICAL GAS PLAN 1431
H-PP1114 LEVEL 1, ZONE 4 - MEDICAL GAS PLAN 1432
H-PP1115 LEVEL 1, ZONE 5 - MEDICAL GAS PLAN 1433
H-PP1121 LEVEL 2, ZONE 1 - MEDICAL GAS PLAN 1434
H-PP1122 LEVEL 2, ZONE 2 - MEDICAL GAS PLAN 1435
H-PP1123 LEVEL 2, ZONE 3 - MEDICAL GAS PLAN 1436
H-PP1124 LEVEL 2, ZONE 4 - MEDICAL GAS PLAN 1437
H-PP1125 LEVEL 2, ZONE 5 - MEDICAL GAS PLAN 1438
H-PP1131 LEVEL 3, ZONE 1 - MEDICAL GAS PLAN 1439
H-PP1132 LEVEL 3, ZONE 2 - MEDICAL GAS PLAN 1440
H-PP1133 LEVEL 3, ZONE 3 - MEDICAL GAS PLAN 1441
ENLARGED PLUMBING PLANS
H-PP4001 ENLARGED PLANS - PLUMBING 1442
H-PP4002 ENLARGED PLANS - PLUMBING 1443
H-PP4003 ENLARGED PLANS - PLUMBING 1444
H-PP4004 ENLARGED PLANS - PLUMBING 1445
H-PP4005 PLUMBING PLAN - MRI 1446
ENLARGED MED GAS PLANS
H-PP4101 ENLARGED PLANS - MED GAS 1447
H-PP4102 ENLARGED PLANS - MED GAS 1448
DETAILS
PP5001 PLUMBING DETAILS 1449
PP5002 PLUMBING DETAILS 1450
PP5003 PLUMBING DETAILS 1451
PP5004 PLUMBING DETAILS 1452
PP5005 PLUMBING DETAILS 1453
PP5006 PLUMBING DETAILS 1454
PP5007 PLUMBING DETAILS 1455
PP5008 PLUMBING DETAILS 1456
PLUMBING - CONT:
SY
M
D
ES
C R
IP
TI
O N
D
Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
GI005.4
IN
DE
X
OF
D
RA
W
IN
GS
PK
L
De sig ne r
BK
H
VO
LU
ME
CO
NT
GI
5.4
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
INDEX OF DRAWINGS
SHEET NUMBER SHEET NAME SEQUENCE REVISION REVISION DATE REVISION DESCRIPTION
HOSPITAL / CLINIC - CONT:
VOLUME 5 CONT.
PLUMBING - CONT.
GENERAL
H-FX0001 FIRE SUPPRESSION SYMBOLS AND ABBREVIATIONS 1535
SITE PLANS
H-FS1001 FIRE SUPPRESSION SITE PLANS 1536
ZONING PLANS
H-FX1010 LEVEL 1 FIRE SUPPRESSION ZONING PLAN 1537
H-FX1020 LEVEL 2 FIRE SUPPRESSION ZONING PLAN 1538
H-FX1030 LEVEL 3 FIRE SUPPRESSION ZONING PLAN 1539
H-FX1040 LEVEL 4 FIRE SUPPRESSION ZONING PLAN 1540
FIRE SUPPRESSION FLOOR PLANS
H-FX1011 LEVEL 1, ZONE 1 - FIRE SUPPRESSION PLAN 1541
H-FX1012 LEVEL 1, ZONE 2 - FIRE SUPPRESSION PLAN 1542
H-FX1013 LEVEL 1, ZONE 3 - FIRE SUPPRESSION PLAN 1543
H-FX1014 LEVEL 1, ZONE 4 - FIRE SUPPRESSION PLAN 1544
H-FX1015 LEVEL 1, ZONE 5 - FIRE SUPPRESSION PLAN 1545
H-FX1021 LEVEL 2, ZONE 1 - FIRE SUPPRESSION PLAN 1546
H-FX1022 LEVEL 2, ZONE 2 - FIRE SUPPRESSION PLAN 1547
H-FX1023 LEVEL 2, ZONE 3 - FIRE SUPPRESSION PLAN 1548
H-FX1024 LEVEL 2, ZONE 4 - FIRE SUPPRESSION PLAN 1549
H-FX1025 LEVEL 2, ZONE 5 - FIRE SUPPRESSION PLAN 1550
H-FX1031 LEVEL 3, ZONE 1 - FIRE SUPPRESSION PLAN 1551
H-FX1032 LEVEL 3, ZONE 2 - FIRE SUPPRESSION PLAN 1552
H-FX1033 LEVEL 3, ZONE 3 - FIRE SUPPRESSION PLAN 1553
H-FX1034 LEVEL 3, ZONE 4 - FIRE SUPPRESSION PLAN 1554
H-FX1035 LEVEL 3, ZONE 5 - FIRE SUPPRESSION PLAN 1555
H-FX1041 LEVEL 4, ZONE 1 - FIRE SUPPRESSION PLAN 1556
H-FX1042 LEVEL 4, ZONE 2 - FIRE SUPPRESSION PLAN 1557
H-FX1043 LEVEL 4, ZONE 3 - FIRE SUPPRESSION PLAN 1558
H-FX1044 LEVEL 4, ZONE 4 - FIRE SUPPRESSION PLAN 1559
DETAILS
FX5001 FIRE SUPPRESSION DETAILS 1560
FX5002 FIRE SUPPRESSION DETAILS 1561
FX5003 FIRE SUPPRESSION DETAILS 1562
FX5004 FIRE SUPPRESSION DETAILS 1563
FX5005 FIRE SUPPRESSION DETAILS 1564
RISER DIAGRAMS
FX6001 FIRE SUPPRESSION RISER DIAGRAMS 1565
SCHEDULES
FX8001 FIRE SUPPRESSION SCHEDULES 1566
FIRE SUPPRESSION
RISER DIAGRAMS
PP6301 MEDICAL GAS RISER DIAGRAMS 1518
PP6302 MEDICAL GAS RISER DIAGRAMS 1519
PP6303 MEDICAL GAS RISER DIAGRAMS 1520
PP6304 MEDICAL GAS RISER DIAGRAMS 1521
PP6305 MEDICAL GAS RISER DIAGRAMS 1522
PP6306 MEDICAL GAS RISER DIAGRAMS 1523
PP6307 MEDICAL GAS RISER DIAGRAMS 1524
PP6308 MEDICAL GAS RISER DIAGRAMS 1525
RISER DIAGRAMS
PP6401 LP GAS RISER DIAGRAM 1526
SEQUENCES
PP7001 PLUMBING SEQUENCES 1527
PP7002 PLUMBING SEQUENCES 1528
PP7101 MEDICAL GAS SEQUENCES 1529
PP7102 MEDICAL GAS SEQUENCES 1530
SCHEDULES
PP8001 PLUMBING SCHEDULES 1531
PP8002 PLUMBING SCHEDULES 1532
PP8003 PLUMBING SCHEDULES 1533
PP8004 PLUMBING SCHEDULES 1534
SY
M
D
ES
C R
IP
TI
O N
D
EF
CO2
PM
73° F 28° F
110° F
WINTER DRY BULB
SUMMER WET BULB (MCWB)
SUMMER DRY BULB
OUTDOOR (CRITICAL):
DESIGN CONDITIONS
GRILLE MARK
DIFFUSER, REGISTER,
EQUIPMENT MARK
GENERAL IDENTIFICATION
EXTENT OF ABBREVIATIONS USED.
REFER TO FLOOR PLANS AND DETAILS FOR
NOTE:
AIR VALVE MARK
AIR VALVE IDENTIFIER
AIR QUANTITY (CFM)
AIR QUANTITY
EQUIPMENT TYPE
SCHEDULE REFERENCE
TYPE
POINT OF REMOVAL - DEMOLITION
POINT OF CONNECTION BETWEEN NEW AND EXISTING CONSTRUCTION
DEMOLITION OF PIPING, DUCTWORK AND EQUIPMENT (DASHED)
EXISTING PIPING, DUCTWORK AND EQUIPMENT TO REMAIN (SCREENED)
72° F 28° F
106° F
WINTER DRY BULB
SUMMER WET BULB (MCWB)
SUMMER DRY BULB
OUTDOOR (NON-CRITICAL):
ABOVE FINISHED FLOOR
AV AIR VALVE
MV MEDICAL VACUUM
ET EXPANSION TANK
CS CLEAN STEAM
PLUMBING PIPINGPL
BG BELOW GROUND
HVAC DESIGNATION
AFF
TRANSFER GRILLETG
NPTS NATIONAL PIPE THREAD STANDARD
PRESSURIZATION MONITORPM
KEF KITCHEN EXHAUST FAN
AFM AIR FLOW MEASURING STATION
DOMESTIC HOT WATER RETURNDHWR REFRIGERANT SUCTION
SIDEWALL SUPPLY REGISTER
SIDEWALL TRANSFER GRILLE
TANK, THERMOSTAT
SWITCH, SOFT WATER
STATIC PRESSURE, SPRINKLER PIPE
SECONDARY RAINWATER
SIDEWALL REGISTER
POUNDS PER SQUARE INCH (ABSOLUTE)
POUNDS PER SQUARE INCH (GAGE)
REGULATING VALVE/POWER ROOF VENTILATOR
RAINWATER LEADER
REVERSE OSMOSIS
REGISTER/REGULATING
POLYVINYL CHLORIDE
PRESSURE REDUCING VALVE/PRESSURE
PLUMBING DRAIN INSTITUTE
SIDEWALL EXHAUST REGISTER
SMOKE/FIRE DAMPER
SMOKE DAMPER, SMOKE DETECTOR,
REHEAT, RELATIVE HUMIDITY
RETURN AIR REGISTER
SUPPLY AIR, SOUND ATTENUATOR
PNEUMATIC CONTROL DAMPER
PNEUMATIC CONTROL VALVE
PRESSURE REDUCING STATION
ROTATIONS PER MINUTE
SOIL
OPPOSED BLADE DAMPER
OVERFLOW DRAIN
OXYGEN
OUTSIDE AIR
TRENCH DRAIN
TEMPERATURE
STRAINER
STEAM FILTER
STORM
SERVICE SINK
SQUARE
SUPPLY GRILLE
SHOWER
SUPPLY FAN
STORM DRAIN
SANITARY
RAINWATER
ROOF TOP UNIT
REHEAT COIL
RETURN FAN
REQUIRED
REFERENCE
ROOF DRAIN
RETURN AIR, RELIEF AIR
PROPELLER
PRESSURE
PHASE
ORAL EVAC
OPERATING
PUMP
PLATE FRAME HEAT EXCHANGER
CB CATCH BASIN
GTV GATE VALVE
FCO
EXH
FA
EWT
ESP
ER
ENT
ENCL
ELEV
EFF
ELEC
DW
ECD
EF
EAT
E/A
DWV
E
DWG
DDC
DG
DH
DEG
DD
DB
DC
CW
DA
CU
CT
CP
CSW
CONN
CO
CH
CI
CEP
CGA
CENT
CDWR
CD
ENTERING WATER TEMPERATURE
FLOOR CLEAN OUT
EXHAUST
FIRE ALARM
EXHAUST REGISTER
EXTERNAL STATIC PRESSURE
ENCLOSE (ENCLOSURE)
ENTERING
EFFICIENCY
ELEVATION
ELECTRIC
NCC
NO.
NO
NC
MPS
N
MED
MH
MIN
MD
NOISE CRITERIA/NORMALLY CLOSED
NORMALLY OPEN/NITROUS OXIDE
NITROGEN CONTROL CABINET
NUMBER
METRES PER SECOND
NITROGEN
MANHOLE
MANUAL DAMPER
MINIMUM
MEDICAL
TD
TEMP
T
SW
STR
STF
STG
ST
SSR
SRW
SS
DOMESTIC WATER (PLUMBING)
DRAIN, WASTE AND VENT PIPING
EXISTING TO REMAIN
ENTERING AIR TEMPERATURE
ELECTRIC CONTROL DAMPER
EXHAUST FAN
EXHAUST AIR
DRAWING
DUCT HEATER
DIRECT DIGITAL CONTROL
DIRECT DRIVE, DECK DRAIN
DIGITAL CONTROLLER
DEGREE
DOOR GRILLE
DRY BULB
LED
MAX
MA
LWT
M
LFD
LPS
IPS
KW
L
LD
INV
HZ
ID
CONDENSING UNIT
COOLING TOWER
CONDENSATE PUMP
COLD SOFT WATER
COLD WATER
DENTAL AIR
CONNECTION
CLEAN OUT
COMPRESSED GAS ASSOCIATION
CENTRAL ENERGY PLANT
CHILLED WATER
CEILING DIFFUSER
CENTRIFUGAL
CONDENSER WATER PUMP
CAST IRON
HX
HWHR
HWH
HW
HSW
HPCW
HVAC
HP
HOR
HOA
HD
HC
HB
GW
H
LIGHT EMITTING DIODE
LEAVING WATER TEMPERATURE
LAMINAR FLOW DIFFUSER
LITERS PER SECOND
MEDICAL AIR
MAXIMUM
METER
HERTZ (CYCLES PER SECOND)
IRON PIPE SIZE
KILOWATT
LINEAR DIFFUSER
LITER
INDIRECT DRAIN
INVERT
SER
SR
SQ
SH
SP
S/FD
SG
SF
SA
SD
SAN
RWL
S
RW
HIGH PRESSURE COLD WATER (DOMESTIC)
HEATING/VENTILATING/AIR CONDITIONING
HOT WATER, HEATING WATER
HORSEPOWER, HEAT PUMP
HOT WATER RETURN
HOT WATER SUPPLY
HEAT EXCHANGER
HOT SOFT WATER
HAND-OFF-AUTOMATIC
HORIZONTAL
HUB DRAIN
HANDICAPPED
HOSE BIBB
GREASE WASTE
HUMIDIFIER
RS
RTU
RR
RPM
RO
RHC
RH
RF
REQD
REG
REF
RD
RA
PVC
PRV
B
BV
CAC
CAP
C
BC
BP
BDD
AUTO
ATC
AS
AP
AHU
AFG
AD
AC
HVAC
COMPUTER ROOM AIR CONDITIONER
AUTOMATIC TEMPERATURE CONTROL
ACCESS DOOR, AIR DRYER, AREA DRAIN
BOILER
CONVERTER, DEGREE CELSIUS
BALANCING VALVE
BACKFLOW PREVENTER
BACK DRAFT DAMPER
BUILDING CONTROLLER
CAPACITY
ABOVE FINISHED GRADE
AIR HANDLING UNIT
ACCESS PANEL
AIR SEPARATOR
AUTOMATIC
FV
GPS
GRV
GLV
GN
GIV
FW
G
F/SD
FS
FO
FFE
FMS
FM
FLR
AIR CONDITIONING UNIT
DESIGNATION
FD
FCU
HVAC
FLUSH VALVE
GRAVITY RELIEF VENTILATOR
GRAVITY INTAKE VENTILATOR
GRAMS PER SECOND
GLOBE VALVE
GENERATOR
GRILLE, GRAMS
FIRE WATER
FINISHED FLOOR ELEVATION
FLOW MEASURING STATION
FIRE/SMOKE DAMPER
FLOOR SINK
FLAT OVAL
FLOW METER
FLOOR(ING)
PSIG
PH
PROP
PRS
PRESS
PCV
PDI
PCD
PSIA
PFHX
P
OPER
OE
OBD
OD
FIRE DAMPER, FLOOR DRAIN
DESIGNATION
FAN COIL UNIT
OA
O
HVAC
UR URINAL
VACUUM BRAKER
VOLUME DAMPER
VARIABLE FREQUENCY DRIVE
VENT, VOLT
VAC
VFD
VD
VB
V
VACUUM
THERMOMETER
THERMOSTATIC MIXING VALVE
TOTAL STATIC PRESSURE
UNIT HEATER
TAMPER SWITCH
WATER PRESSURE DROP
WELDED WIRE FABRIC
WET BULB
WALL HYDRANT
WALL CLEANOUT
WATER CLOSET
WATER HAMMER ARRESTOR
WATER METER
VENT THROUGH ROOF
TRAP PRIMER, STEAM TRAP
WC
WWF
UN
WPD
WH
WM
WHA
WCO
UNION
TSP
UH
TS
TMV
VTR
W
WB
WASTE
TP
DESIGNATION
TH
DIFFERENTIAL PRESSURE SWITCHDPS
DIFFERENTIAL PRESSURE TRANSMITTERDPT
PT PRESSURE TRANSMITTER
SST STAINLESS STEEL
REFRIGERANT LIQUID LINERL
CD
CARBON DIOXIDE MONITOR
PRESSURIZATION MONITOR
1.0
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1' -0
MH001
ME
CH
AN
IC
AL
S
YM
BO
LS
A
ND
A
BB
RE
VI
AT
IO
NS
JA
A
BE
F
JB
H
MH
SY
M
D
ES
C R
IP
TI
O N
D
T
H
DESIGNATION
FUEL OIL SUPPLY
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
DESIGNATION
CHEMICAL FEEDCF
HVAC PIPING
DRAIN
CHILLED WATER RETURN
CHILLED WATER SUPPLY
FUEL OIL RETURN
FUEL OIL FILL
CHWR
CHWS
D
CWS
VENT
MAKE-UP WATER (DOMESTIC COLD WATER)
MRI CHILLED WATER RETURN
MRI CHILLED WATER SUPPLY
V
CW
MCWR
MCWS
COMPRESSED AIR
BUTTERFLY
CHECK - SWING GATE
CHECK - SPRING LOADED
BALL
CA
VALVES
GLOBE
GLOBE - ANGLE PATTERN
GATE
DESIGNATIONDUCTWORK
SMOKE DETECTOR
12X6
DUCT CONNECTION
HUMIDITY SENSOR
ROOM SENSOR (TEMPERATURE/HUMIDITY)
CEILING DIFFUSER - BOTTOM
LINEAR SLOT DIFFUSER
FIGURE IS SIDE SHOWN
RECTANGULAR DUCT, FIRST
STANDARD BRANCH TAKEOFF
DESIGNATION
SQUARE SUPPLY AIR DIFFUSER
DUCTWORK
EXHAUST AIR REGISTER
RETURN AIR REGISTER/GRILLE
TRANSFER AIR REGISTER/GRILLE
SUPPLY AIR DUCT - SECTION
ELBOW TURNED UP
ELBOW TURNED DOWN
RETURN AIR DUCT - SECTION
EXHAUST AIR DUCT - SECTION
24Ø
VERTICAL POSITION
HORIZONTAL POSITION
F/SD VERTICAL POSITION
F/SD HORIZONTAL POSITION
TRANSITION - ECCENTRIC
FIRE DAMPERS
COMBINATION FIRE/SMOKE DAMPER
DUCT ACCESS DOOR
ROUND DUCT, DIAMETER SHOWN
TRANSITION - CONCENTRIC
HUMIDIFIER
TOP/SIDE/BOTTOM
DUCT TRANSITION.
WITH REHEAT COIL
REHEAT COIL / COOLING COIL
VARIABLE AIR VOLUME TERMINAL UNIT
RECTANGULAR/SQUARE TO ROUND
TEE TURNED UP
LEAF TYPE
TEE TURNED DOWN
MANUAL DAMPER - SINGLE
MANUAL DAMPER - OPPOSED BLADE
FLEXIBLE CONNECTION
TYPE (UNLESS NOTED OTHERWISE)
MOTOR ACTIVATED CONTROL DAMPER
OFFSET IN DUCTWORK - UPUP
OFFSET IN DUCTWORK - DOWN
TURNING VANES - SQUARE ELBOW
DN
NOTE: REFER TO FLOOR PLANS AND DETAILS FOR
EXTENT OF SYMBOLS AND ABBREVIATION USED.
DESIGNATIONPIPING SPECIALITIES
DIRECTION OF PIPING PITCH
DIRECTION OF FLOW
DESIGNATION
FLOW BALANCING
VALVES-SPECIAL DUTY
SAFETY RELIEF
LUBRICATED PLUG
DESIGNATION
TEE (TURNED UP)
TEE (TURNED DOWN)
PIPE FITTINGS
PRESSURE REDUCING/REGULATING
PRESSURE GAGE
STRAINER - Y PATTERN
PRESSURE GAGE W/ SNUBBER
THERMOMETER
FLOW METER
STEAM TRAP (BUCKET)
PRESSURE AND TEST FITTING
UNION - GROUND JOINT
REDUCER - CONCENTRIC
CAPPED LINE
BLIND FLANGED CAP
PLUGGED LINE
SPOOL PIECE - FLANGED
FLANGED
VALVE IN RISER
SCREWED/SOLDERED/WELDED
ELBOW (90°)
ELBOW (45°)
ELBOW (TURNED UP)
ELBOW (TURNED DOWN)
REDUCER - ECCENTRIC, STRAIGHT CROWN
REDUCER - ECCENTRIC, STRAIGHT INVERT
TEE
ELBOW (BASE)
(1" BALL VALVE AND CAP)
STRAINER - Y PATTERN WITH BLOWDOWN
FLEXIBLE CONNECTION - ELASTOMERIC
CWR
FOS
FOR
FOF
STATIC PRESSURE TRANSMITTERDPT
CONCEALED COVER PLATE FOR ACCESS TO
REMOTE ACTUATOR OF MANUAL BALANCE
DAMPERS ABOVE HARD CEILING
CARBON DIOXIDE MONITOR
CLEAN STEAMCS
HIGH PRESSURE STEAM (PSIG)
LOW PRESSURE CONDENSATE RETURNLPC
LOW PRESSURE STEAM (PSIG)LPS(15)
PUMPED CONDENSATEPC
HIGH PRESSURE CONDENSATE RETURN
MEDIUM PRESSURE CONDENSATE RETURN
MEDIUM PRESSURE STEAM (PSIG)
MPC
MPS(60)
HPC
HPS(90)
CO2
HOT WATER SUPPLYHWS
HWR HOT WATER RETURN
REFRIGERANT SUCTIONRS
REFRIGERANT LIQUIDRL
STEAM TRAP (FLOAT & THERMOSTATIC)
THREE-WAY CONTROL VALVE
TWO-WAY CONTROL VALVE
RADIUS ELBOW
S
PRESSURIZATION MONITORPM
FIRE WALL LEGEND
VALVES-SPECIAL DUTY DESIGNATION
DESIGNATION
AIR VENT - MANUAL
PIPING SPECIALITIES
EXPANSION LOOP
AUTOMATIC AIR VENT W/BALL VALVE
ANCHOR - PIPING
ALIGNMENT PIPE GUIDES
FLEXIBLE CONNECTION - BRAIDED
AV
MV
MAKE-UP WATER (DOMESTIC SOFT WATER)SW
SD
FIGURE IS SIDE SHOWN
FLAT OVAL DUCT, FIRST
18X12Ø
FLAT OVAL RADIUS ELBOW
WELDED BLACK STEEL DUCT
DIRECTION OF FLOW
SMOKE PARTITION
SMOKE BARRIER
1 HOUR FIRE BARRIER
1 HOUR SMOKE BARRIER
2 HOUR FIRE BARRIER
2 HOUR SMOKE BARRIER
1HRFS
2HRFS
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
MH002
ME
CH
AN
IC
AL
S
YM
BO
LS
A
ND
A
BB
RE
VI
AT
IO
NS
JA
A
BE
F
JB
H
MH
SY
M
D
ES
C R
IP
TI
O N
D
DRAWINGS. CONDUCT REMOVAL/CAPPING
REQUIREMENTS INDICATED ON DUCT INSTALLATION
COORDINATE DUCT REMOVAL WITH CAPPING
SEQUENTIALLY TO MINIMIZE SYSTEM DOWNTIME.
8.
OR EXHAUST FANS. SUBMIT REPORT TO
AND SHALL INCLUDE A LIST OF SERVICES
REMAIN AND SERVED BY NEW SUPPLY, RETURN
BOLD TYPE, FOR AREAS WITH DUCTWORK TO
MEASURE EXISTING AIR VOLUMES, INDICATED BY
D. AIR TERMINAL VALVES AND/OR REHEAT
B. VALVES, CONTROL AND MANUAL TYPE.
RETAIN AND RETURN THE FOLLOWING EQUIPMENT
MINIMUM OF 14 DAYS PRIOR TO INTENDED ACTION
CONTRACTING OFFICER PRIOR TO
7.
C. METERS AND GAUGES.
A. CONTROL EQUIPMENT.
6.
REMOVAL. NOTIFICATION SHALL BE PROVIDED A
SYSTEMS FOR EQUIPMENT AND DUCTWORK
OFFICER PRIOR TO SHUTDOWN OF AIR
OBTAIN APPROVAL FROM CONTRACTING
SERVICE TO ADJACENT AREAS AT TIMES THAT
PERFORM WORK THAT MAY INTERRUPT ANY
DUCTWORK AND PIPING DEMOLITION WITH AREAS
TEMPORARY PARTITIONS, TEMPORARY CAPS,
COORDINATE SEQUENCE OF CONSTRUCTION,
CONSTRUCTION AND LIMITS OF WORK SPACE.
ADDITIONAL INFORMATION REGARDING
REFER TO ARCHITECTURAL PHASING PLANS FOR
WILL NOT DISRUPT FACILITY OPERATION.
5.
4.
3.
CONDITIONS THAT MAY AFFECT NEW WORK.
OFFICER OF ANY VARIATIONS IN EXISTING
DEMOLITION. NOTIFY CONTRACTING
CONDITIONS PRIOR TO PROCEEDING WITH
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
DUCTWORK AND EQUIPMENT INDICATED ARE
2.
1.
TO PROTECT EXISTING DUCTWORK FROM
CONSTRUCTION AT RETURN AND EXHAUST GRILLES
PROVIDE ADDITIONAL TEMPORARY FILTERS DURING
CONSTRUCTION DEBRIS AND DUST.
9.
EXISTING.
RECORD DISCREPANCIES ON RECORD DRAWINGS.
CONSTRUCTION PERIOD.
TO BE MAINTAINED IN OPERATION DURING THE
AFFECTED, SCHEDULE OF WORK, AND PLANNED
START DATE.
TO OWNER:
COILS.
PROCEEDING WITH DEMOLITION WORK.
SYMBOLS AND ABBREVIATIONS.
REFER TO SHEET MH001 AND MH002 FOR MECHANICAL10.
DEMOLITION DUCTWORK SHEET NOTES
DRAWINGS. CONDUCT REMOVAL/CAPPING
REQUIREMENTS INDICATED ON PIPING INSTALLATION
COORDINATE PIPE REMOVAL WITH CAPPING
SEQUENTIALLY TO MINIMIZE SYSTEM DOWNTIME.
8.
PRIOR TO PROCEEDING WITH DEMOLITION WORK.
AND SHALL INCLUDE A LIST OF SERVICES
SUBMIT REPORT TO CONTRACTING OFFICER
PIPING TO REMAIN AND SERVED BY NEW PIPING.
MEASURE EXISTING FLOWS FOR AREAS WITH
D. AIR TERMINAL VALVES AND/OR REHEAT
B. VALVES, CONTROL AND MANUAL TYPE.
RETAIN AND RETURN THE FOLLOWING EQUIPMENT
MINIMUM OF 14 DAYS PRIOR TO INTENDED ACTION
7.
C. METERS AND GAUGES.
A. CONTROL EQUIPMENT.
6.
REMOVAL. NOTIFICATION SHALL BE PROVIDED A
SYSTEMS FOR EQUIPMENT AND PIPING
OFFICER PRIOR TO SHUTDOWN OF WATER
OBTAIN APPROVAL FROM CONTRACTING
SERVICE TO ADJACENT AREAS AT TIMES THAT
PERFORM WORK THAT MAY INTERRUPT ANY
DUCTWORK AND PIPING DEMOLITION WITH AREAS
TEMPORARY PARTITIONS, TEMPORARY CAPS,
COORDINATE SEQUENCE OF CONSTRUCTION,
CONSTRUCTION AND LIMITS OF WORK SPACE.
ADDITIONAL INFORMATION REGARDING
REFER TO ARCHITECTURAL PHASING PLANS FOR
WILL NOT DISRUPT FACILITY OPERATION.
5.
4.
3.
CONDITIONS THAT MAY AFFECT NEW WORK.
OFFICER OF ANY VARIATIONS IN EXISTING
DEMOLITION. NOTIFY CONTRACTING
CONDITIONS PRIOR TO PROCEEDING WITH
CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
PIPING AND EQUIPMENT INDICATED ARE
2.
1.
EXISTING.
RECORD DISCREPANCIES ON RECORD DRAWINGS.
CONSTRUCTION PERIOD.
TO BE MAINTAINED IN OPERATION DURING THE
AFFECTED, SCHEDULE OF WORK, AND PLANNED
START DATE.
TO OWNER:
COILS.
10.
DEMOLITION HVAC PIPING SHEET NOTES
1.
RENOVATION DUCTWORK SHEET NOTES
AGENCY AT START OF RENOVATION.
SCHEDULE OF WORK,AND PLANNED START DATE.
CONSTRUCTION PERIOD.
VALVES AND AIR TERMINALS.
TILE CEILINGS ARE CONSIDERED NON-ACCESSIBLE.
ARCHITECTURAL APPROVAL.
AT THE SITE.
CONSTRUCTION DEBRIS AND DUST.
17. PROVIDE ADDITIONAL TEMPORARY FILTERS DURING
CONSTRUCTION AT RETURN AND EXHAUST GRILLES
TO PROTECT EXISTING DUCTWORK FROM
16. REFER TO DUCTWORK SPECIFICATIONS FOR DUCT
CONSTRUCTION MATERIALS AND PRESSURE CLASS.
IN RELATION TO OCCUPIED AREAS. UTILIZING A
MAGNEHELIC PRESSURE GAUGE OR OTHER
QUANTITIES. REPLACE SHEAVES WHEN REQUIRED.
PLANS. FINAL LOCATION REQUIRES
2.
3.
5.
4.
6.
7.
8.
9.
10.
DUCT SIZES NOTED INDICATE MINIMUM INSIDE DIMENSIONS.
MINIMUM DUCT SIZE IS 10X6 EXCEPT WHERE
SPECIFICALLY INDICATED OTHERWISE.
DUCTWORK LOCATIONS SHOWN ARE SCHEMATIC.
REFER TO SPECIFICATIONS FOR SHOP DRAWING
AND COORDINATION DRAWING REQUIREMENTS. DO
NOT PROCEED WITH INSTALLATION OF DUCTWORK
COORDINATE CEILING DIFFUSER, REGISTER AND
GRILLE LOCATIONS WITH REFLECTED CEILING
SIDEWALL REGISTERS AND LINEAR TYPE DIFFUSERS
SHALL BE INSTALLED PLUMB AND LEVEL ALONG A
COMMON ELEVATION IN SPACE SERVED.
INSIDE AREAS OF DUCTWORK VISIBLE THROUGH
DIFFUSERS, REGISTERS, GRILLES AND LOUVERS
PROVIDE ACCESS DOORS IN DUCTWORK FOR
VISUAL INSPECTION OF ALL CONTROL DAMPERS,
TEMPERATURE CONTROL DEVICES, SMOKE
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE
GENERAL CONSTRUCTION SUBSTRATES FOR
MAINTENANCE AND ADJUSTMENT OF ALL
CONCEALED DAMPERS, AIR CONTROL DEVICES,
WOOD, GYPSUM DRYWALL AND CONCEALED SPLINE
REFER TO TYPICAL DETAIL SHEETS FOR GENERAL
DUCTWORK CONSTRUCTION, INSTALLATION,
ASSEMBLY DETAILS, AND CONNECTIONS TO AIR
REFER TO MECHANICAL PIPING FLOOR PLANS FOR
THERMOSTAT AND TEMPERATURE SENSOR LOCATIONS.
UNTIL APPROVED SHOP DRAWINGS ARE AVAILABLE
SHALL BE PAINTED FLAT BLACK.
DETECTORS, FIRE DAMPERS AND SMOKE DAMPERS.
EQUIPMENT AND DUCTWORK ACCESS DOORS.
11.
12.
14.
15.
13.
REFER TO ARCHITECTURAL PHASING PLANS FOR
ADDITIONAL INFORMATION REGARDING NEW
CONSTRUCTION AND LIMITS OF WORK SPACE.
COORDINATE SEQUENCE OF NEW CONSTRUCTION,
DUCTWORK AND PIPING INSTALLATION WITH AREAS
TO BE MAINTAINED IN OPERATION DURING THE
PERFORM WORK THAT MAY INTERRUPT ANY
SERVICE TO ADJACENT AREAS AT TIMES THAT
OBTAIN APPROVAL FROM CONTRACTING OFFICER
PRIOR TO SHUTDOWN OF AIR SYSTEMS FOR EQUIPMENT
AND DUCTWORK INSTALLATION. NOTIFICATION SHALL BE
PROVIDED A MINIMUM OF 14 DAYS PRIOR TO INTENDED
BALANCE EXISTING AND NEW BRANCH DUCTS,
QUANTITIES INDICATED BY BOLD TYPE. ADJUST
AIR SYSTEMS FOR SCHEDULED PHASING AIR
OBSERVE PRESSURIZATION OF ADJACENT OCCUPIED
SPACES ON A DAILY BASIS TO MAINTAIN THE
AREA OF RENOVATION AT A NEGATIVE PRESSURE
APPROVED METHOD AT TEMPORARY PARTITION
WALLS. AIR QUANTITIES SHALL BE SET AND
MEASURED BY A CERTIFIED TEST AND BALANCE
TEMPORARY PARTITIONS, TEMPORARY CAPS,
WILL NOT DISRUPT FACILITY OPERATION.
ACTION AND SHALL INCLUDE LIST OF SERVICES AFFECTED,
DIFFUSERS, REGISTERS, AND GRILLES FOR NEW AIR
1.
RENOVATION HVAC PIPING SHEET NOTES SEISMIC/ANTITERRORISM FORCE PROTECTION NOTES:
14 DAYS PRIOR TO INTENDED ACTION AND SHALL
SCHEDULED PHASING WATER QUANTITIES.
BOLD TYPE. ADJUST WATER SYSTEMS FOR
BRANCH PIPING FOR NEW FLOWS INDICATED BY
PRIOR TO DEMOLITION. REBALANCE EXISTING
BALANCE EXISTING PIPING TO FLOWS MEASURED
SCHEDULE OF WORK, AND PLANNED START DATE.
INCLUDE A LIST OF SERVICES AFFECTED,
11.
OFFICER PRIOR TO SHUTDOWN OF SYSTEMS
COORDINATE WITH LIFE SAFETY PLANS. REFER TO
NOTIFICATION SHALL BE PROVIDED A MINIMUM OF
FOR EQUIPMENT AND PIPING INSTALLATION.
OBTAIN APPROVAL FROM CONTRACTING
WILL NOT DISRUPT FACILITY OPERATION.
SERVICE TO ADJACENT AREAS AT TIMES THAT
PERFORM WORK THAT MAY INTERRUPT ANY
CONSTRUCTION PERIOD.
MAINTAINED IN OPERATION DURING THE
10.
9.
PIPING INSTALLATION WITH AREAS TO BE
TEMPORARY PARTITIONS, TEMPORARY CAPS,
COORDINATE SEQUENCE OF NEW CONSTRUCTION,
CONSTRUCTION AND LIMITS OF WORK SPACE.
ADDITIONAL INFORMATION REGARDING NEW
TYPICAL PIPE SLEEVE DETAILS.
PENETRATIONS THROUGH RATED ASSEMBLIES.
PROVIDE FIRE RATED SLEEVES FOR PIPING
REFER TO ARCHITECTURAL PHASING PLANS FOR8.
7.
UNDER 3.0 GPM SHALL BE 3/4" UNLESS
CONCEALED VALVES, FLOW CONTROL DEVICES AND
PIPING LOCATIONS SHOWN ARE SCHEMATIC. REFER
COORDINATION DRAWING REQUIREMENTS. DO NOT
CEILINGS ARE CONSIDERED NON-ACCESSIBLE.
GYPSUM DRYWALL AND CONCEALED SPLINE TILE
EQUIPMENT. REFER TO SPECIFICATIONS. WOOD,
MAINTENANCE AND ADJUSTMENT OF ALL
GENERAL CONSTRUCTION SUBSTRATES FOR
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE
APPROVED SHOP DRAWINGS ARE AVAILABLE AT
PROCEED WITH INSTALLATION OF PIPING UNTIL
THE SITE.
6.
TO SPECIFICATIONS FOR SHOP DRAWING AND
CONNECTIONS AND ASSEMBLY DETAILS.
ADDITIONAL VALVING, ACCESSORIES, EQUIPMENT
REFER TO TYPICAL DETAIL SHEETS FOR
MOUNT ROOM THERMOSTATS/SENSORS AT
SPECIFICALLY NOTED OTHERWISE.
4.
5.
48 INCHES AFF.
3.
REFER TO DIVISION 23 SPECIFICATIONS FOR ALL
BRANCH PIPING SIZES NOT SHOWN ON PLANS
MINIMUM BRANCH PIPING SIZE SHALL BE 3/4".
PIPING CONSTRUCTION AND INSTALLATION
REQUIREMENTS.
2.
SYMBOLS AND ABBREVIATIONS.
REFER TO SHEET MH001 AND MH002 FOR MECHANICAL
9.
AFFECTED BY DEMOLITION AREAS. REPLACE AT THE
PROVIDE STRAINERS AT EXISTING PUMPS
END OF EACH PHASE.
AND HIGH POINTS IN THE PIPING SYSTEMS.
PROVIDE DRAIN AND MANUAL AIR VENTS AT LOW12.
SUPPORT OF PIPING, DUCTWORK, AND EQUIPMENT SHALL
SEISMIC SPECIFICATIONS. PROVIDE NON-SEISMIC SUPPORTS AT
WITH SPECIFICATIONS.
1.
ATTACHMENTS TO STRUCTURE FOR SUSPENDED PIPING,
PLACE CONCRETE RIBS ONLY. FOR LOCATIONS WHERE
STEEL TO BRIDGE BETWEEN RIBS FOR CONNECTION POINTS.
2.
BE AS INDICATED ON DETAIL SHEETS AND AS REQUIRED BY THE
ADDITIONAL INTERVALS, IN EXCESS OF THAT REQUIRED TO COMPLY
DUCTWORK, AND EQUIPMENT SHALL BE MADE CAST IN
CAST IN PLACE RIBS ARE NOT AVAILABLE, USE ANGLE
3.
4.
ALL FLOOR MOUNTED MECHANICAL EQUIPMENT WITH VIBRATION
ISOLATION SHALL BE EQUIPPED WITH SEISMIC RESTRAINTS
AND SEISMIC SNUBBERS.
SHOP DRAWING FOR SEISMIC REQUIREMENTS ARE REQUIRED,
REFER TO SPECIFICATIONS. DO NOT PROCEED UNTIL SHOP
DRAWINGS ARE APPROVED AND AVAILABLE AT THE SITE.
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1' -0
MH003
ME
CH
AN
IC
AL
T
YP
IC
AL
S
HE
ET
N
OT
ES
JA
A
BE
F
JB
H
MH
SY
M
D
ES
C R
IP
TI
O N
D
REFER TO SCHEDULES FOR DUCT CONSTRUCTION
MATERIALS AND PRESSURE CLASS.
11.
AND COORDINATION DRAWING REQUIREMENTS. DO
TEMPERATURE CONTROL DEVICES, SMOKE
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE
GENERAL CONSTRUCTION SUBSTRATES FOR
MAINTENANCE AND ADJUSTMENT OF ALL
CONCEALED DAMPERS, AIR CONTROL DEVICES,
WOOD, GYPSUM DRYWALL AND CONCEALED SPLINE
REFER TO TYPICAL DETAIL SHEETS FOR GENERAL
DUCTWORK CONSTRUCTION, INSTALLATION,
ASSEMBLY DETAILS AND, CONNECTIONS TO AIR
REFER TO MECHANICAL PIPING FLOOR PLANS FOR
THERMOSTAT AND TEMPERATURE SENSOR
EQUIPMENT AND DUCTWORK ACCESS DOORS.
10.
9.
DETECTORS, FIRE DAMPERS AND SMOKE DAMPERS.
8.
NOT PROCEED WITH INSTALLATION OF DUCTWORK
COORDINATE CEILING DIFFUSER, REGISTER AND
GRILLE LOCATIONS WITH REFLECTED CEILING
SIDEWALL REGISTERS AND LINEAR TYPE DIFFUSERS
SHALL BE INSTALLED PLUMB AND LEVEL ALONG A
INSIDE AREAS OF DUCTWORK VISIBLE THROUGH
DIFFUSERS, REGISTERS, GRILLES AND LOUVERS
PROVIDE ACCESS DOORS IN DUCTWORK FOR
VISUAL INSPECTION OF ALL CONTROL DAMPERS,
UNTIL APPROVED SHOP DRAWINGS ARE AVAILABLE
COMMON ELEVATION IN SPACE SERVED.
SHALL BE PAINTED FLAT BLACK.
7.
6.
4.
5.
DUCT SIZES NOTED INDICATE MINIMUM INSIDE
MINIMUM DUCT SIZE IS 10X6 EXCEPT WHERE
DUCTWORK LOCATIONS SHOWN ARE SCHEMATIC.
REFER TO SPECIFICATIONS FOR SHOP DRAWING
SPECIFICALLY INDICATED OTHERWISE.
3.
2.
PLANS. FINAL LOCATION REQUIRES
DUCT HANGERS TO BE INSTALLED 4 FEET ON
CENTER WHERE DUCTWORK TAKES UP MORE THAN
12.
60 PERCENT OF THE CEILING GRID. COORDINATE
AREAS WITH CONTRACTING OFFICER AND
CEILING CONTRACTOR TO UTILIZE DUCT HANGERS
VALVES AND AIR TERMINALS.
AT THE SITE.
ARCHITECTURAL APPROVAL.
TEE CEILINGS ARE CONSIDERED NON-ACCESSIBLE.
LOCATIONS.
FOR SUSPENDED CEILINGS.
DIMENSIONS.
1.
DUCTWORK SHEET NOTES
THE DUCT CONFIGURATION(S) SHOWN. INCLUDING TURNS
AND CONFIGURATION OF PATHWAY, ARE INTENDED TO
13.
MITIGATE NOISE TRANSMISSION, AND THAT THE
CONTRACTOR'S DUCTWORK SHOP DRAWING SHOULD REFLECT
EQUIVALENT ATTENUATING CHARACTERISTICS.
CONTRACTOR SHALL MODIFY DUCTWORK GAUGE OR PROVIDE
ANGLE STIFFENERS TO DUCTWORK TO PREVENT VIBRATION
14.
AND FLEXING OF THE DUCTWORK SYSTEMS.
1.
HVAC PIPING SHEET NOTES
1.
ENLARGED PLAN SHEET NOTES
COORDINATE WITH LIFE SAFETY PLANS. REFER TO
TYPICAL PIPE SLEEVE DETAILS.
PENETRATIONS THROUGH RATED ASSEMBLIES.
PROVIDE FIRE RATED SLEEVES FOR PIPING7.
UNDER 3.0 GPM SHALL BE 3/4" UNLESS
CONCEALED VALVES, FLOW CONTROL DEVICES AND
PIPING LOCATIONS SHOWN ARE SCHEMATIC. REFER
COORDINATION DRAWING REQUIREMENTS. DO NOT
CEILINGS ARE CONSIDERED NON-ACCESSIBLE.
GYPSUM DRYWALL AND CONCEALED SPLINE TILE
EQUIPMENT. REFER TO SPECIFICATIONS. WOOD,
MAINTENANCE AND ADJUSTMENT OF ALL
GENERAL CONSTRUCTION SUBSTRATES FOR
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE
APPROVED SHOP DRAWINGS ARE AVAILABLE AT
PROCEED WITH INSTALLATION OF PIPING UNTIL
THE SITE.
6.
TO SPECIFICATIONS FOR SHOP DRAWING AND
CONNECTIONS AND ASSEMBLY DETAILS.
ADDITIONAL VALVING, ACCESSORIES, EQUIPMENT
REFER TO TYPICAL DETAIL SHEETS FOR
MOUNT ROOM THERMOSTATS/SENSORS/MONITORS
SPECIFICALLY NOTED OTHERWISE.
4.
5.
AT 48 INCHES AFF.
3.
REFER TO DIVISION 23 SPECIFICATIONS FOR ALL
BRANCH PIPING SIZES NOT SHOWN ON PLANS
MINIMUM BRANCH PIPING SIZE SHALL BE 3/4".
PIPING CONSTRUCTION AND INSTALLATION
REQUIREMENTS.
2.
ACCESSORIES AND ASSEMBLY DETAILS.
SAFETY PLANS. REFER TO TYPICAL PIPE SLEEVE DETAILS.
DUCTWORK AND PIPING TO MECHANICAL EQUIPMENT SHALL
MATERIALS AND PRESSURE CLASS.
REFER TO SCHEDULES FOR DUCT CONSTRUCTION9.
THROUGH RATED ASSEMBLIES. COORDINATE WITH LIFE
PROVIDE FIRE RATED SLEEVES FOR PIPING PENETRATIONS
EQUIPMENT SERVICE CLEARANCES TO OTHER COMPONENTS
COMPONENTS FOR MECHANICAL DUCTWORK, PIPING AND
COORDINATE INSTALLATION OF TEMPERATURE CONTROL
8.
7.
6.
SMOKE DETECTORS, FIRE DAMPERS AND SMOKE DAMPERS.
WITH INSTALLATION OF DUCTWORK, PIPING AND CONNECTED
DUCTWORK AND PIPING LOCATIONS SHOWN ARE SCHEMATIC.
DUCT SIZES NOTED INDICATE MINIMUM INSIDE DIMENSIONS.
AT THE SITE. INDICATE EQUIPMENT ACCESS REQUIREMENTS.
AND PIPING CONSTRUCTION, INSTALLATION, VALVING,
REFER TO TYPICAL DETAIL SHEETS FOR GENERAL DUCTWORK
OF ALL CONTROL DAMPERS, TEMPERATURE CONTROL DEVICES,
PROVIDE ACCESS DOORS IN DUCTWORK FOR VISUAL INSPECTION
5.
4.
EQUIPMENT UNTIL APPROVED SHOP DRAWINGS ARE AVAILABLE
COORDINATION DRAWING REQUIREMENTS. DO NOT PROCEED
REFER TO SPECIFICATIONS FOR SHOP DRAWING AND
SHALL BE 3/4" UNLESS SPECIFICALLY NOTED OTHERWISE.
SIZE OF ACCESS DOORS SCHEDULED ON FIRE DAMPER
INSTALLATION DETAILS.
BE INSTALLED IN A MANNER THAT DOES NOT OBSTRUCT
MINIMUM BRANCH PIPING SIZE SHALL BE 3/4". BRANCH
3.
2.
PIPING SIZES NOT SHOWN ON PLANS UNDER 3.O GPM
OR EQUIPMENT.
CONSTRUCTION AND INSTALLATION REQUIREMENTS.
REFER TO DIVISION 23 SPECIFICATIONS FOR ALL PIPING10.
EQUIPMENT.
1.
SCHEMATIC FLOW DIAGRAM SHEET NOTES
REFER TO DIVISION 23 SPECIFICATIONS FOR ALL PIPING
PIPING SIZES NOT SHOWN ON PLANS UNDER 3.0 GPM SHALL
3.
2.
EQUIPMENT CONNECTIONS AND ASSEMBLY DETAILS.
CONSTRUCTION, INSTALLATION, VALVING, ACCESSORIES,
REFER TO TYPICAL DETAIL SHEETS FOR GENERAL PIPING
MINIMUM BRANCH PIPING SIZE SHALL BE 3/4". BRANCH
CONSTRUCTION AND INSTALLATION REQUIREMENTS.
BE 3/4" UNLESS SPECIFICALLY NOTED OTHERWISE.
COMMUNICATION POINTS REQUIRED WITH CONTROL DRAWINGS.
COMPONENTS FOR MECHANICAL PIPING AND EQUIPMENT, AND
COORDINATE INSTALLATION OF TEMPERATURE CONTROL4.
REFER TO MI7 SHEETS.
EQUIPMENT LOCATIONS.
REFER TO PLAN SHEETS AND ENLARGED PLAN SHEETS FOR5.
1.
SITE PLAN SHEET NOTES
OF DIVISION 02 SPECIFICATIONS FOR THE GROUNDWATER
ELEVATION.
REFER TO THE SOIL BORINGS INCLUDED IN ATTACHMENTS
HOT AND CHILLED WATER PIPING CONSTRUCTION AND
REFER TO DIVISION 23 SPECIFICATIONS FOR ABOVE GROUND
CONSTRUCTION AND INSTALLATION EXTERIOR TO BUILDINGS
SPECIFICATIONS FOR HOT AND CHILLED WATER PIPING
REFER TO NOTATIONS ON THIS DRAWING AND DIVISION 23
SYMBOLS AND ABBREVIATIONS. REFER TO SHEET PL0001
REFER TO SHEET MH001 AND MH002 FOR MECHANICAL
INSTALLATION INTERIOR TO BUILDINGS.
FOR PLUMBING SYMBOLS AND ABBREVIATIONS.
4.
3.
AND STRUCTURES.
2.
AND HIGH POINTS IN THE PIPING SYSTEMS.
PROVIDE DRAIN AND MANUAL AIR VENTS AT LOW8.
AND HIGH POINTS IN THE PIPING SYSTEMS.
PROVIDE DRAIN AND MANUAL AIR VENTS AT LOW11.
AND HIGH POINTS IN THE PIPING SYSTEMS.
PROVIDE DRAIN AND MANUAL AIR VENTS AT LOW6.
FOR MECHANICAL WALL MOUNTED
REFER TO INTERIOR ELEVATIONS AND EQUIPMENT ELEVATIONS9.
DEVICE LOCATIONS (i.e.: THERMOSTATS/HUMIDISTATS, CONTROL PANELS)
ALL DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED
IN A FURRED CHASE OR ABOVE SUSPENDED CEILING.
15.
UNDER THE ARCHITECTURAL SPECIFICATIONS.
ACCESS PANELS SHALL BE FURNISHED AND INSTALLED
UNDER THE ARCHITECTURAL SPECIFICATIONS.
ACCESS PANELS SHALL BE FURNISHED AND INSTALLED
CONCEALED IN A FURRED CHASE OR ABOVE
ALL PIPE IN FINISHED ROOMS OR SPACES SHALL BE10.
SUSPENDED CEILING.
AND AIR.
SHALL BE MADE TO PROVIDE COUNTERFLOW BETWEEN WATER
WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING COILS7.
OF OBSTRUCTIONS TO PERMIT EQUIPMENT REMOVAL AT
MAINTAIN SERVICE WALKWAYS WITHIN PENTHOUSE CLEAR12.
ACCESS PANELS AND LOUVERS IN THE FUTURE.
EQUIPMENT ROOMS UNLESS INDICATED OR NOTED OTHERWISE.
MAINTAIN MINIMUM CLEARANCE HEIGHT OF 7'-6" AT PENTHOUSE AND13.
FOR MECHANICAL WALL MOUNTED
REFER TO INTERIOR ELEVATIONS AND EQUIPMENT ELEVATIONS16.
DEVICE LOCATIONS (i.e.: SIDEWALL DEVICES, ETC.)
NOT INDICATED ON DUCTWORK PLANS.
REFER TO PIPING PLANS FOR ROOM SENSORS AND CO2 SENSORS17.
AT 48 INCHES AFF.
MOUNT ROOM THERMOSTATS/SENSORS/MONITORS18.
CO2 SENSORS NOT INDICATED ON PIPING PLANS.
REFER TO DUCTWORK PLANS FOR MONITORS, ROOM SENSORS AND11.
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1' -0
MH004
ME
CH
AN
IC
AL
T
YP
IC
AL
S
HE
ET
N
OT
ES
JA
A
BE
F
JB
H
MH
SY
M
D
ES
C R
IP
TI
O N
D
HOSPITALCLINIC
HOSPITALCLINIC HOSPITALCLINIC
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1' -0
MH1AB
AH
U
ZO
NI
NG
P
LA
NS
JA
A
BE
F
JB
H
MH
1A
B
LEVEL 2LEVEL 1 LEVEL 3
AHU-3.1
AHU-3.2
AHU-3.4
AHU-3.3
AHU-2.1
AHU-2.2
AHU-2.4
AHU-2.3
AHU-2.5
AHU-1.2
AHU-1.1
AHU-1.5
AHU-1.4
AHU-1.3
AHU-C.1
SURGERY
CMS
NUTRITIONAL CARE
FACILITIES MANAGMENT
LOGISTICS
RADIOLOGY
LAB
PHARMACY
EMERGENCY
OPTOMETRY
WOMEN'S HEALTH
PRIMARY CARE
CAREER COUNSELOR
TRICARE
SURGERY CLINIC
MED / SURG UNIT
MANGED CARE
BEHAVIORAL HEALTH
PAD (PRIVATE)
QUALITY MANAGEMENT
COMMAND
LDRP UNIT
CUP ADMIN
CENTRAL UTILITY PLANT
AHU ZONING PLANS1
V
SY
M
D
ES
C R
IP
TI
O N
D
UP
SD
SD
SD
COMM
COMM
COMM
JAN
JAN
MED STOR
CLEAN
DECONTAM
OR
ORTHO EQUIP
ORTHO OR
CAST STG
SCRUB
SUBSTERILE
STERILE CORE
EQUIP
LITTER
11C08a
CLEAN LINEN
11C09a
SOILED LINEN
PROCTO EQUIP
PROCTO EXAM
SC WASH
(CLEAN)
F LKR
M LKR
SHR
1114a
SHR
1113a
LOUNGE
ANES WORK
MED STOR
1148 CHIEF ANES
EMPTY G
FULL G
NCOIC
RN SUPER
OR TECH
DECONTAM
JAN
STERILIZATION
JAN
1203STERILE STOR
VEND
11C03a
NORMAL
POWER
ATS
EMERGENCY
POWER
ELEC
SC WASH
(DIRTY)
ATM
11C03a
F TLT
M TLT
CAREER
COUNSELOR
WAIT
TLT
TLT
EL 1 EL 2 EL 3
CORR
11C08
CORR
11C09
ELEV LOBBY
CORR
11C11
CORR
11C07
CORR
11C06
CORR
11C05
CORR
11C12
CORR
11C03
CORR
11C04
CORR
11C02
ELEV LOBBY
EL 4
EL 5
EL 6
ELEVATOR
MACHINES
STAIR 1
11S01
ELEV MACH RM
ELEVATOR
MACHINES
RE
F
LIN
E
H- M H
RE
F
LIN
E
H- M H
REF LINE
H-MH1013
REF LINE
H-MH1013
20x2620x26
33X14Ø
30X14Ø
DN
33X14Ø
UP
DN
DN
x1
DN
DN
DN
UP
DN
DN
UP
DN
UP
DN
DN
DN
UP
28x12
UP
UP
UP
32x14
CD-A
CD-A
14x
1.2.11
DN
8ø
DN
1.2.10
10x8
CD-A
CD-A
CD-A
DN
DN
CD-C
x8
CD-A
DN
CD-A
CD-A
CD-A
1.2.9
X1
4Ø
DN
DN
CD-A
DN
UP
CD-A
x6 x8
1.2.14
UP
18X10Ø
X8
Ø
CD-D
CD-A
140CD-A
10x8
1.2.12
1.2.13
CD-C
CD-A
1.2.8
UP
CD-A
CD-A
CD-C
1.2.6
CD-D
10x8
CD-A
16x10
DN
8ø
28x14 10 x8
CD-A
CD-C
1.2.7
22x10 x1
UP
RR-D
RR-A
RR-C
14x6
DN
12x6
RR-A
x1
24x10
UP
RR-A
UP
RR-A
18x8
DN
DN18x8
12x6
RR-A
12x6
RR-A
14x6
RR-A
UP
RR-A
RR-C
RR-A
14x6
12x8 x1
DN
ER-C
DN
ER-D
UP
DN
UPER-A
x1
20x10 x1
ER-C
DN
16x8 x6 x8
ER-A
ER-A
UP
ER-C
32x14
CD-A
SSR-A
10X6/120
CD-A
12x8 16x8
CD-A
1.1.16
DN
14X8Ø
10x8
CD-A
CD-A
1.1.15
CD-A
CD-A
185305
1.1.17
X8
Ø
8ø
14X8Ø
X8
Ø
1.1.18
DN
CD-A
CD-A
x8
DN
CD-A
SSR-A
10X6/90
SSR-A
10X6/80 x8
DN
UP
18x8
SSR-A
10X8/340
CD-A
DN
1.1.11
SSR-A
10X8/270
10x8 270 1.1.1314x8 420
1.1.14
CD-A
10ø
14X8Ø
10ø
DN
1.1.12
CD-C
CD-C
SSR-A
12X8/410 ø
CD-A
8ø
1.1.8
DN
CD-C
CD-C
CD-A
CD-A
CD-A
10ø
X1
4Ø
X1
4Ø
X1
4Ø
SSR-A
10X6/80
DN
UP
DNCD-A
1.1.1 x8
10x8
33X14Ø
SSR-A
10X6/80
CD-A
20X12Ø 33 X1
4Ø x6
28x10
CD-A
CD-A
CD-A
1.5.18
14x10
38x18
33X14Ø
33X14Ø
28x12
10x6 10x6
14x6
SRR-A
10X6/120
SRR-A
10X6/80
UP
RR-A
UP
SRR-A
10X6/210
1.1.9 410
1.1.10
UP
DN
x8
RR-A
x1
18x10
SRR-A
10X6/140
12x6
RR-A
12x8
SRR-A
10X6/90
18x10
RR-A
SRR-A
10X6/70
24x10
RR-A
x1
20x10
16x8
DN
UP
RR-A
12x6 x8 x8
RR-A
RR-A
10x8
25X12Ø
SRR-A
10X6/80
RR-A
x6
RR-A
ER-D
UP
16x8 x8
ER-C
ER-C
UP
x6
DN
16x10 16x10
DN
UP
14x6
16x8
UP
ER-C
ER-C
12x6 x8
10x8
12x6
ER-C
ER-C
UP
ER-C
ER-C
10x8 x8
32x12
ER-D
80ER-D
10x8
10x6
14x6
H-MH4008
FD FD
10x8
FD
FD
12x8
FD
(2)FD
(2) FD
10x6
RR-A
H-MH4022
H-MH4023
H-MH4023
FD
16x8
28x10
UP
40x16
10x8
RR-A
x1
UP
x8
UP
33X14Ø x1
14x6
14x8 20 x1
012x8
10x8 x6
12x8
40x26 12x8
28x10
UP
14x8
20x10
FCU
G
FCU
G
DPT
DPT
F/SD-2
FCU
H
FCU
D
FCU
F
FCU
B
FCU
E
FD
FCU
F
FCU
I x1
10x6 x6
15X10Ø
X1
2Ø x6
28x12 12x6 x1
10x6
12x10
1.2.15
SSR-A
12X8/405
SSR-A
12X8/400
24x8 12x8 x8
SSR-A
16X16/1500
SSR-A
16X16/1500
36x12 x1
6 16 x1
SSR-A
16X16/1500
SSR-A
16X16/1500 x1 x1
16x16
6 7 8 9 10
A
B
C
D
E.1
6.7
A.3
Z
5.9
7.4
7.7
4.5
6.2 6.25
Z.1
E
UP 18
x8 x6
14x6
14x6
UP
33X14Ø
28x14
DN
28x14 32x14
12x8
UP
DN
14x8 14x8
14x8 14x8 x8
This is the start of the file's text. The full file is on GovTribe.