079200.Q11
076000.H02 6
061000.C11
055013.T02 1
072200.R02
053000.A01
075423.A01
072200.P02
44"
1'
- 2
077200.C03
075423.A01 061000.C12
079200.Q11
077200.C02 3
076000.H02 6
061000.C12
1 1 /2"
3'
- 0
" M
IN
IM
UM
053000.A07
072200.P02
4 072200.R02
075423.C05 075423.A01 072200.P02 072200.R02
2"
DISTANCE BETWEEN SCUPPERS
"X"
W
ID
TH
O
F C R
IC
KE
T "X
"/4
076000.U04
1/ 2"
:1 2"
1":12"
1" :1
2"
1/ 2"
:1 2"
075423.A01
076000.M04
074213.A04C
076000.M04
054000.D06C 092900.B03
054000.D06C
072200.P02 075423.A01
072200.R03 051200.E01
053000.A01
051200.A01
14053000.A01
051200.B03
051200.A0114
15 075423.A01
075423.A01 072200.P02 072200.R02 053000.A01
051200.A01
054000.C01
051200.A0114
092900.B03
072713.A01
1' - 3 1/4"
P-AE526
P-1
071353.A01
054000.D06C
042000.D03C
076000.M08076000.H02
072713.A01 092900.B01C
074213.A04C 054000.D06C
051200.A01
2' - 10" VIF
TO PRECAST
24' - 0"
072200.R02
076000.U02
(BEYOND)
076000.M04
BO PRECAST
8' - 8"
SCUPPER
14' - 4"
034500.A03
6"9 1 /2" 075423.A01
072200.R02
1 3 /4"
092423.A01 092423.A11 092900.B01C
072713.A01
H-AE504
4 3/4"
053000.A07
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE521
RO
OF
D
ET
AI
LS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
MATERIAL NOTES
034500.A03 PRECAST CONCRETE WALL
PANEL
042000.D03C CMU 8"
051200.A01 STEEL BEAM
051200.B03 STEEL TUBE COLUMN
051200.E01 STEEL ANGLE
053000.A01 STEEL DECK
053000.A07 STEEL ROOF DECK
054000.C01 STEEL STUD RUNNER TRACK
054000.D06C STEEL STUD 6"
055013.T02 ANCHOR BOLT
061000.C11 PRESSURE TREATED WOOD
BLOCKING
061000.C12 CONTINUOUS PRESSURE
TREATED WOOD BLOCKING
071353.A01 COMPOSITE, SELF-ADHERING
SHEET MEMBRANE
WATERPROOFING
072200.P02 GLASS MAT GYPSUM
PROTECTION BOARD
072200.R02 ROOF INSULATION BOARD
072200.R03 TAPERED ROOF INSULATION
072713.A01 SELF-ADHERED MEMBRANE AIR
BARRIER
074213.A04C FACTORY INSULATED WALL
PANEL 2" THICK
075423.A01 SINGLE PLY THERMOPLASTIC
ROOFING SYSTEM
075423.C05 ROOF WALKWAY PAD
076000.H02 COUNTERFLASHING
076000.M04 PARAPET COPING
076000.M08 PARAPET COPING SYSTEM
076000.U02 DOWNSPOUT
076000.U04 SCUPPER
077200.C02 EQUIPMENT SUPPORT CURB
077200.C03 EQUIPMENT TIE-DOWN PIPE
079200.Q11 SEALANT BED
092423.A01 STUCCO
092423.A11 SELF FURRING DIAMOND MESH
LATH
092900.B01C GYPSUM BOARD, GLASS MAT
FACED 5/8"
092900.B03 GLASS MAT COVERED OR
REINFORCED GYPSUM
SHEATHING
1 PER MANUFACTURER'S UPLIFT REQUIREMENTS
2 NEOPRENE PAD SET IN SEALANT
3 INSULATED, PREFABRICATED
4 R-25 MINIMUM, CONTINUOUS
5 CONTINUOUS FULL BED 1-1/2" MIN. WIDE.
6 REMOVABLE COUNTERFLASHING & FASTENERS w/
NEOPRENE GASKETS @ 12" O.C.
7 CONTINUE PILES UNDER COUNTERFLASHING.
8 APPROVED EQUIPMENT FASTENERS w/ NEOPRENE
WASHER
9 WRAP OVER TOP OF BLOCKING & DOWN EA. SIDE
CONTINUOUS UNDER CAP FLASHING
10 CONTINUOUS BRAKEMETAL LIPPED CAP FLASHING
w/ WELDED CORNERS
11 PRECAST SUPPORT BY PRECAST SUPPLIER
12 ALL ROOF WALKWAY PADS 2' X 4', TYP
13 SPLICE LAP MEMBRANE OVER COPING LEG
14 BEYOND
15 CONTINUE PLIES UP PRECAST & UNDER MODIFIED
COPING
16 METAL CAVITY CLOSURE @ END OF PRECAST
(BEYOND)
17 SEALANT CAP BEAD
18 FULL BED OF SEALANT AND SEALANT ALL AROUND
19 ALIGN THIS PORTION OF WALL WITH PRECAST
PANEL BEYOND.
20 TRANSITION TO COPING AT BOTH ENDS
21 ROOF MFR'S STANDARD EDGE DETAIL WITH CONT
CLEAT
15"10"5"2"
3"=1'-0" GRAPHIC SCALE
01"
3" = 1'-0"
EQUIPMENT CURB SUPPORT1
3" = 1'-0"
EXHAUST FAN/GRAVITY VENTILATOR
CURB2
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
3" = 1'-0"
WALK PAD DETAIL3
1/4" = 1'-0"
TYPICAL ROOF CRICKET4
1 1/2" = 1'-0"
PARAPET DETAIL5
1'-0"0
1"=1'-0" GRAPHIC SCALE
6" 2'-0"3" 4'-0"
3/4"=1'-0" GRAPHIC SCALE
6" 0 4'-0"1'-0" 2'-0"
3/4" = 1'-0"
METAL PANEL AT ROOF6
1" = 1'-0"
PRECAST PARAPET7
1/4"=1'-0" GRAPHIC SCALE
15'10'5'1'01'
30"20"10"2"0
1 1/2"=1'-0" GRAPHIC SCALE
2"
SY
M
D E S
C R
IP
TI
O N
D
AT
E
075423.A01
076000.H20
075423.Q02
055013.A02
055100.R43
055013.Z02
055013.X04 8
6"
4"
072200.P02
8" M
IN
IM
UM
10072200.R02MI
N4"
" C
LE
AR
A T
SO
LA
R
PA
NE
L S
UP
PO
RT
051200.A01
076000.Z04
076000.Z04
055013.E06
220070.C31
079200.Q01
053000.A07
072200.R02
072200.P02
MI
N4"
075423.Q02
076000.Z04
076000.Z04
8" M
IN
IM
UM
075423.A01
076000.Z02
075423.Q02
079200.Q01
079200.Q01
055013.Z02
9"
072200.P024"
10072200.R02
075423.A01 061000.C12
075423.H11
077200.A01
" M
IN
055100.A01
053000.A07 072200.R02
055200.R01
072200.P02
079200.Q02
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE522
RO
OF
D
ET
AI
LS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
1 SEE 3/P-SF505 FOR CONNECTIONS
2 3" DIA., GALVANIZED
3 ROLL PIPE FLASHING OVER TOP & FOLD DOWN INTO
PIPE EVENLY.
4 6" MIN. METAL FLANGE SET IN COMPATIBLE FULL
BED OF ROOFING SEALANT OVER BASE PLY (LAP
CAP SHEET OVER FLANGE).
5 FACTORY MOLDED PIPE BOOT FLASHING
6 REFER TO ELECTRICAL DOCUMENTS FOR CONDUIT
MOUNTING CONDITIONS AND LOCATIONS TYP.
7 CIRCULAR PLATE WELD TO PIPE TOP & GRIND
EDGES SMOOTH.
8 STAINLESS STEEL.
10 R-25 MINIMUM, CONTINUOUS
11 DRAW BAND
12 ONLY REQUIRED AT ROOF FLUE DETAIL 2/P-AE523
13 SEALANT ALL AROUND
MATERIAL NOTES
051200.A01 STEEL BEAM
053000.A07 STEEL ROOF DECK
055013.A02 STEEL PIPE
055013.E06 STEEL PLATE
055013.X04 GUY CABLES
055013.Z02 STAINLESS STEEL EYEHOOK
055100.A01 STEEL STAIR
055100.R43 PLATE CLOSURE, WELD AND
GRIND SMOOTH
055200.R01 STEEL GUARDRAIL
061000.C12 CONTINUOUS PRESSURE
TREATED WOOD BLOCKING
072200.P02 GLASS MAT GYPSUM
PROTECTION BOARD
072200.R02 ROOF INSULATION BOARD
075423.A01 SINGLE PLY THERMOPLASTIC
ROOFING SYSTEM
075423.H11 THERMOPLASTIC BASE
FLASHING
075423.Q02 MASTIC SEALANT
076000.H20 PIPE FLASHING
076000.Z02 SHEET METAL COLLAR
076000.Z04 CLAMPING RING
077200.A01 ROOF HATCH
079200.Q01 JOINT SEALANT
079200.Q02 BACKSTOP AND SEALANT
220070.C31 VENT PIPING
15"10"5"2"
3"=1'-0" GRAPHIC SCALE
01"
30"20"10"2"0
1 1/2"=1'-0" GRAPHIC SCALE
2"
3" = 1'-0"
EQUIPMENT SUPPORT / TIE DOWN/
PANELSUPPORT1
3" = 1'-0"
PLUMBING PIPE PENETRATION2
3" = 1'-0"
SMALL PIPE PENETRATION3 1 1/2" = 1'-0"
ROOF ACCESS HATCH5
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
SY
M
D E S
C R
IP
TI
O N
D
042000.W01
072113.R01
042000.W01
053000.A01
TO CMU PARAPET
24' - 0"
075423.H10034500.A03
051200.A01
072200.P02
072200.R02 5
075423.A01
4"
SLOPE DN
1/2
076000.M04
P-4
1' - 5".
SEE MECHANICAL DRAWINGS
10" DIA FLUE
079200.Q11 6
079200.Q01
076000.Z03
W/ THIMBLE MANUFACTURES REQUIREMENTS
COORDINATE ROUGH ROOF OPENING & CLEARANCES
076000.H02
072200.R02 053000.A01
072200.P02
1'
- 2
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
3"
1' -0
P-AE523
RO
OF
D
ET
AI
LS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
MATERIAL NOTES
034500.A03 PRECAST CONCRETE WALL
PANEL
042000.W01 REINFORCING STEEL
051200.A01 STEEL BEAM
053000.A01 STEEL DECK
072113.R01 BOARD THERMAL INSULATION
072200.P02 GLASS MAT GYPSUM
PROTECTION BOARD
072200.R02 ROOF INSULATION BOARD
075423.A01 SINGLE PLY THERMOPLASTIC
ROOFING SYSTEM
075423.H10 THERMOPLASTIC WALL
FLASHING
076000.H02 COUNTERFLASHING
076000.M04 PARAPET COPING
076000.Z03 DRAW BAND
079200.Q01 JOINT SEALANT
079200.Q11 SEALANT BED
1 CUSTOM PROFILE COPING CAP FORMED IN 10'-0"
LENGTHS. WITH 18 GA CLIP BELOW
2 CUSTOM COLOR, FACTORY APPLIED TO MATCH
PRECAST
3 REFER TO MECHANICAL DETAILS FOR ADDITIONAL
CURB & ROOFING INFORMATION
4 REFER TO MECHANICAL DETAILS FOR VENTILATED
JACKETED ROOF THIMBLE & FLUE STACK
5 R-25 MINIMUM, CONTINUOUS. CRICKET AT
PERIMETER
6 FULL BEAD AROUND PERIMETER
7 REFER TO DETAIL 3/P-SF501 FOR OPENING
REINFORCING
8 REMOVABLE COUNTERFLASHING
9 BOLTED MIN. 2 PER SIDE & LEVEL TO ACCOMMODATE
STACK & THIMBLE
10 CENTER FLUE AND THIMBLE OPENING BETWEEN
STEEL BEAMS
11 EXTEND ROOF MEMBRANE TO BELOW NAILER AND
SECURE. ALL SEAMS TO BE FULLY WELDED.
12 SEE STRUCTURAL DRAWINGS FOR SIZE AND NUMBER
TYP.
13 6-IN WIDE CONCEALED JOINT SPLICE W/PREFORMED
CHANNEL FOR WATER CONTROL
15"10"5"2"
3"=1'-0" GRAPHIC SCALE
01"
3" = 1'-0"
PARAPET1 3" = 1'-0"
ROOF FLUE PENETRATION2
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
SY
M
D E S
C R
IP
TI
O N
D
072113.R01
053000.A01
051200.A02
TO PARAPET
24' - 0"
075423.H10
034500.A03
1'
- 2
4"
076000.U03
1"
079200.Q11
(VARIES)
T/ STRUCTURE
20'-4"
075423.A01
6" 072200.P02
089100.K029
P-AE524
4"
SLOPE DN
1/2
076000.M04
8"
VI
F
5 3 /4"
051200.E02
1' - 5".
061000.C11
1'
- 3
1' - 4"
2" 4"
2"
10"
1'
- 0
8"
8"
B.O. SCUPPER
OPENING
6"
1"
3"
P-AE524
P-1
1'
- 8
075423.A01
072200.R02
076000.H02
079200.Q01
034500.A03
1"
072200.R02
042000.D03C
072200.R02 072200.P02
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE524
RO
OF
D
ET
AI
LS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
MATERIAL NOTES
034500.A03 PRECAST CONCRETE WALL
PANEL
042000.D03C CMU 8"
042000.W01 REINFORCING STEEL
051200.A02 STEEL WIDE FLANGE BEAM
051200.E02 STEEL PLATE
053000.A01 STEEL DECK
061000.C11 PRESSURE TREATED WOOD
BLOCKING
072113.R01 BOARD THERMAL INSULATION
072200.P02 GLASS MAT GYPSUM
PROTECTION BOARD
072200.R02 ROOF INSULATION BOARD
075423.A01 SINGLE PLY THERMOPLASTIC
ROOFING SYSTEM
075423.H10 THERMOPLASTIC WALL
FLASHING
076000.H02 COUNTERFLASHING
076000.M04 PARAPET COPING
076000.U03 CONDUCTOR HEAD
079200.Q01 JOINT SEALANT
079200.Q11 SEALANT BED
089100.K02 WIRE BIRD SCREEN
1 CUSTOM PROFILE COPING CAP FORMED IN 10'-0"
LENGTHS. WITH 18 GA CLIP BELOW
2 CUSTOM COLOR, FACTORY APPLIED TO MATCH
PRECAST
3 6" x 8" OPENING INTO CONDUCTOR HEAD
4 SCUPPER OVERFLOW OPENING, HEM EDGES ALL
AROUND OPENING.
5 SEE STRUCTURAL DRAWINGS FOR SIZE AND
NUMBER TYP.
6 CONCRETE BEAM TO MATCH OPENING HEIGHT
7 4X6 DOWNSPOUT
8 6-IN WIDE CONCEALED JOINT SPLICE W/PREFORMED
CHANNEL FOR WATER CONTROL
9 STAINLESS STEEL
10 SEALANT ALL SIDES
11 EXTEND ROOF MEMBRANE TO BELOW NAILER AND
SECURE. ALL SEAMS TO BE FULLY WELDED.
12 SHEET METAL SCUPPER OPENING
13 ONE PIECE SURFACE MOUNTED REGLET
14 CONTINUOUS BEAD
15"10"5"2"
3"=1'-0" GRAPHIC SCALE
01"
3" = 1'-0"
PARAPET DETAIL AT SCUPPER1
3" = 1'-0"
CONDUCTOR HEAD ELEVATION2
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
1 1/2" = 1'-0"
ROOF FLASHING3
30"20"10"2"0
1 1/2"=1'-0" GRAPHIC SCALE
2"
SY
M
D E S
C R
IP
TI
O N
D
TO CMU PARAPET
23' - 0"
TO CMU PARAPET
24' - 0"
(BEYOND)
034500.A01
075423.H11
SLOPE DN
4" 1/2
1 1 /2"
076000.M04
072113.R01
11".
1' - 4"1' - 2"
1'
- 3
5"
4" M
IN
4" MIN
076000.U02
092900.B01C
054000.D06C
092900.B01C
053000.A07072713.A01
076000.U01
075423.H10 061000.C11 072200.R02
072200.P02 075423.A01
074213.A04C
074213.A04C
072713.A01 092900.B01C
051200.A01
075423.A01
072200.R02 054000.D06C
P-AE526
072200.P02
092900.B01C
075423.H11
SIM
074213.A04C
054000.D06C
054000.D06C
072200.R02
051200.A01
092900.B01C
092900.B01C 072713.A01
092900.B01C
2 P-AE526
072200.P02
SIM
092900.R20
074213.A04C
OPH
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE525
RO
OF
D
ET
AI
LS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
3" = 1'-0"
LOW PARAPET1
1 SET IN SEALANT, ALL SIDES
2 SLOPE TOP OF COPING BACK TO ROOF
3 EXTEND ROOF MEMBRANE TO BELOW NAILER AND
SECURE. ALL SEAMS TO BE FULLY WELDED.
4 PROVIDE METAL SADDLE FLASHING PER DETAIL 1 &
2 ON P-AE526
5 CUSTOM PROFILE COPING CAP FORMED IN 10'-0"
LENGTHS
6 CUSTOM COLOR, FACTORY APPLIED TO MATCH
PRECAST
7 6-IN WIDE CONCEALED JOINT SPLICE W/PREFORMED
CHANNEL FOR WATER CONTROL
8 EXTEND ROOF MEMBRANE TO BELOW NAILER AND
SECURE. ALL SEAMS TO BE FULLY WELDED.
9 4" x 6"
10 METAL FLASHING
11 2" ACOUSTICAL INSULATION (ENTIRE SURFACE OF
GENERATOR INTAKE)
12 1/2" x 1/2" HARDWARE CLOTH AT ACOUSTICAL
INSULATION
13 HEM AND BEND ALL AROUND. CONTINUOUS BEAD
OF SEALANT.
MATERIAL NOTES
034500.A01 PRECAST CONCRETE SHAPE
042000.W01 REINFORCING STEEL
051200.A01 STEEL BEAM
053000.A07 STEEL ROOF DECK
054000.D06C STEEL STUD 6"
061000.C11 PRESSURE TREATED WOOD
BLOCKING
072113.R01 BOARD THERMAL INSULATION
072200.P02 GLASS MAT GYPSUM
PROTECTION BOARD
072200.R02 ROOF INSULATION BOARD
072713.A01 SELF-ADHERED MEMBRANE AIR
BARRIER
074213.A04C FACTORY INSULATED WALL
PANEL 2" THICK
075423.A01 SINGLE PLY THERMOPLASTIC
ROOFING SYSTEM
075423.H10 THERMOPLASTIC WALL
FLASHING
075423.H11 THERMOPLASTIC BASE
FLASHING
076000.M04 PARAPET COPING
076000.U01 GUTTER
076000.U02 DOWNSPOUT
092900.B01C GYPSUM BOARD, GLASS MAT
FACED 5/8"
092900.R20 SOUND ATTENUATION BATTS
3" = 1'-0"
SCUPPER CONDUCTOR HEAD ISOMETRIC2
1 1/2" = 1'-0"
GUTTER DETAIL4 1 1/2" = 1'-0"
PARAPET DETAIL5
30"20"10"2"0
1 1/2"=1'-0" GRAPHIC SCALE
2"
15"10"5"2"
3"=1'-0" GRAPHIC SCALE
01"
1 1/2" = 1'-0"
PARAPET DETAIL3
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
SY
M
D E S
C R
IP
TI
O N
D
4" Min.
054000.D06C
3/4"
074213.E05
092900.B01C
072713.A01
074213.A04C
TO FLOOR
033100.B01
074213.A04C
054000.D06C072713.A017
092900.B01C
092900.B01C
1/2
TO REVEAL
VARIES
072713.A01
074213.A04C
092900.B01C092900.B01C
075423.H10
076000.M04 075423.H11
054000.C01
054000.D06C
074213.E05
1' - 0"
. 1' - 0"
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE526
DE
TA
ILS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
1 ONE PIECE METAL SADDLE FLASHING TO MATCH
FINISH OF PARAPET COPING CAPS. INSTALL AT ALL
PARAPET HEIGHT TRANSIITIONS OVER COPING
2 MATCH SLOPE OF METAL COPING
3 MATCH DIMENSION OF METAL COPING
4 CONTINOUS PERIMETER SEAL
5 CONTINOUS 1/4" SHIM OR 1/4" SHIM AT
FASTENING-STUD LOCATIONS
6 NON-CURING BUTYL SEALANT
7 OVER VERTICAL LEG OF BASE EXTRUSION
8 GASKET BY METAL PANEL MANUFACTURER
9 CONTINUOUS BACKER AT JOINTS
10 CONCEALED BUTYL SEALANT
11 EXTEND ROOFING PAST METAL COPING
12 SEE ENLARGED DETAIL TO LEFT
13 CLOSURE FLASHING
14 HIGH TEMP, CONTINUOUS, EXTEND DOWN
OPPOSITE SIDE 2"
30"20"10"2"0
1 1/2"=1'-0" GRAPHIC SCALE
2"
6" = 1'-0"
TYPICAL METAL PANEL INSTALLATION5 6" = 1'-0"
METAL PANEL BASE4
6" = 1'-0"
COPING AT METAL PANEL3 1 1/2" = 1'-0"
CUSTOM ONE PIECE SADDLE FLASHING1
7"5"3"1"
6"=1'-0" GRAPHIC SCALE
01/2"
CUSTOM ONE PIECE SADDLE FLASHING2
MATERIAL NOTES
033100.B01 CONCRETE SLAB
054000.C01 STEEL STUD RUNNER TRACK
054000.D06C STEEL STUD 6"
072713.A01 SELF-ADHERED MEMBRANE AIR
BARRIER
074213.A04C FACTORY INSULATED WALL
PANEL 2" THICK
074213.E05 THERMAL SPACER
075423.H10 THERMOPLASTIC WALL
FLASHING
075423.H11 THERMOPLASTIC BASE
FLASHING
076000.M04 PARAPET COPING
092900.B01C GYPSUM BOARD, GLASS MAT
FACED 5/8"
SY
M
D E S
C R
IP
TI
O N
D
TOS
20' - 0"
051200.B03 092900.B01C 054000.D06C
051200.A01
075423.A01
072200.R02
053000.A07
072713.A01
072200.P02
074213.A04C 076000.H01
076000.H02 076000.Z01
8"
M in.
P-AE526
075423.H11
SIM
054000.D06C 072713.A01
051200.A01
074213.M01
2' - 11 1/2"
2'
- 0
1/ 2"
2074213.A04C
SLOPE 1/8" / 12"
092900.B01C
2' - 5" 6"
TO STEEL
10' - 0"
FF
0' - 0"
033100.A086"
- 4
054000.D06C 092900.B01C 072713.A01
051200.E03
P-AE526
074213.A04C
075423.A01 072200.R02
072713.A01 092900.B01C
054000.D06C
072200.P02
075423.H11
P-AE526
OPP.P-F
074213.A04C
TOS
26' - 0"
TO PARAPET
29' - 0"
053000.A07
033100.A09
033100.A05
033100.V01 310000.A02
033100.V01
087100.S20 079200.Q015
1/4 " 075423.A01
072200.R02
072713.A01
072200.P02
074213.A04C
076000.H02
076000.Z01
1' - 1 1/4"
125°
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE527
DE
TA
ILS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
1 1/2" = 1'-0"
FLASHING AT WALL1
1 1/2" = 1'-0"
BEAM SURROUND DETAIL2
1 1/2" = 1'-0"
LOW DETAIL AT METAL PANEL3
30"20"10"2"0
1 1/2"=1'-0" GRAPHIC SCALE
2"
1 1/2" = 1'-0"
METAL PANEL PARAPET5
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
1 16" O.C.
2 ON 1/4" SPACER
3 SHEET METAL PLATE
4 2-HOUR PROTECTED STRUCTURE AT ROOMS P-1131
AND P-1132
5 EDGE OF PRECAST BEYOND
6 EDGE OF CMU BEYOND
7 SEE 2/P-SB501 FOR FOUNDATION AND SLAB
8 SEE CIVIL DRAWING FOR SIDEWALK
9 ALIGN SLAB EDGE AT OPENING
10 DOOR FRAME TO COVER WALL JOINT
11 ALIGN WITH BUILDING FACE
12 CLOSURE PANEL, SEE MECHAICAL DRAWINGS.
MATERIAL NOTES
033100.A05 CONCRETE FLOOR
033100.A08 CONCRETE CURB
033100.A09 CONCRETE FOUNDATION WALL
033100.V01 VAPOR BARRIER
051200.A01 STEEL BEAM
051200.B03 STEEL TUBE COLUMN
051200.E03 STEEL PLATE, BENT
053000.A07 STEEL ROOF DECK
054000.D06C STEEL STUD 6"
072200.P02 GLASS MAT GYPSUM
PROTECTION BOARD
072200.R02 ROOF INSULATION BOARD
072713.A01 SELF-ADHERED MEMBRANE AIR
BARRIER
074213.A04C FACTORY INSULATED WALL
PANEL 2" THICK
074213.M01 METAL TRIM
075423.A01 SINGLE PLY THERMOPLASTIC
ROOFING SYSTEM
075423.H11 THERMOPLASTIC BASE
FLASHING
076000.H01 METAL FLASHING
076000.H02 COUNTERFLASHING
076000.Z01 TERMINATION BAR
079200.Q01 JOINT SEALANT
087100.S20 THRESHOLD
092900.B01C GYPSUM BOARD, GLASS MAT
FACED 5/8"
310000.A02 FILL MATERIAL
3" = 1'-0"
DOOR/LOUVER SILL AT THICK PRECAST4
1 1/2" = 1'-0"
METAL PANEL BASE6
SY
M
D
ES
C R
IP
TI
O N
D
5"
055013.T03 051200.E01
083323.A01 083323.B01
042000.D03C
042000.A01
042000.D06
042000.W01
081113.D016
042000.W01
6 081113.D01
042000.D03C
042000.G02
081113.T01
042000.A01
042000.D06
042000.W01
H-AE565
SEE WALL TYPE
042000.G10
EQ EQ
2" 1/2
081113.D04
MASONRY SIZE
042000.D03C
042000.G10
061000.C03
2"
081113.D04
TO MASONRY
OPENING
14' - 0"
083323.B03
083323.B01 083323.A01
5" M
IN
1' - 1"
079200.Q01
034500.A03
1' - 4 1/2"
MI
N4"
3/4
083323.C01 033100.A05
083323.A01 083323.B01 034500.A03 8
SLOPE 1/4"
055013.E01
033100.V01
2"
042000.D03C
081113.D04
042000.W01
042000.D07
081113.D01
042000.D07
042000.G02
034500.A03 072200.R02
079200.Q01
4"
081113.T01
054000.D01
079200.Q01 2"
074213.A04C
079200.Q01
5 3 /4"
081113.D01
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
3"
1' -0
P-AE541
DO
OR
A
ND
W
IN
DO
W
D
ET
AI
LS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
3" = 1'-0"
COILING DOOR JAMB DETAIL3
3" = 1'-0"
INTERIOR DOOR HEAD4
3" = 1'-0"
INTERIOR DOOR JAMB5
3" = 1'-0"
INTERIOR WINDOW HEAD6
3" = 1'-0"
INTERIOR WINDOW SILL8
MATERIAL NOTES
033100.A05 CONCRETE FLOOR
033100.V01 VAPOR BARRIER
034500.A03 PRECAST CONCRETE WALL
PANEL
042000.A01 MASONRY UNIT
042000.D03C CMU 8"
042000.D06 CMU LINTEL
042000.D07 CMU BULLNOSE
042000.G02 GROUT
042000.G10 GROUT SOLID
042000.W01 REINFORCING STEEL
051200.E01 STEEL ANGLE
054000.D01 STEEL STUD
055013.E01 STEEL ANGLE
055013.T03 EXPANSION BOLT
061000.C03 WOOD SHIM
072200.R02 ROOF INSULATION BOARD
074213.A04C FACTORY INSULATED WALL
PANEL 2" THICK
079200.Q01 JOINT SEALANT
081113.D01 STEEL DOOR FRAME
081113.D04 STEEL GLAZED OPENING FRAME
081113.T01 MASONRY ANCHOR
083323.A01 OVERHEAD ROLLING DOOR
083323.B01 ROLLING DOOR GUIDES
083323.B03 ROLLING DOOR HOOD
083323.C01 BOTTOM BAR/WEATHER SEAL
1 1" HM GLAZING STOP
2 2" x 2" x 1/4" GALVANIZED ANGLE EMBEDDED
3 SETTING BLOCK @ SILLS
4 AT FIRE RATED CONDITIONS, PROVIDE RATED
ASSEMBLY
6 WRAP AROUND MASONRY FRAME, GALVANIZED
7 PER DOOR MANUFACTURER
8 BEYOND
9 SEE STRUCTURAL DRAWINGS FOR REINFORCING
10 BENT PLATE 13X4X1/4" HEAD AND JAMBS
11 4X4X3/8
12 OPTIONAL - NOTCHED PRECAST LINTEL MAY ALSO
BE USED TO ALIGN WITH MASONRY COURSING.
13 JAMB COVER EXTRUSION
14 EDGE OF PRECAST BEYOND
15 PRECAST THICKNESS AND STEEL CONNECTIONS BY
PRECAST CONCRETE MANUFACTURER
16 MATCH INTERIOR FRAME WIDTH
17 MIN 3/8" DIA ANCHOR WITH 2 5/8" MIN EMBEDMENT @
2'-0" OC MAX
18 DRIP REVEAL
15"10"5"2"
3"=1'-0" GRAPHIC SCALE
01"
3" = 1'-0"
OVERHEAD DOOR HEAD DETAIL1
3" = 1'-0"
OVERHEAD DOOR SILL DETAIL2
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
3" = 1'-0"
INTERIOR WINDOW JAMB7
3" = 1'-0"
EXTERIOR DOOR JAMB9
3" = 1'-0"
EXTERIOR DOOR JAMB AT PANEL10
SY
M
D
ES
C R
IP
TI
O N
D
P-1
P-D
081116.A01
042000.D07
042000.D03C
079200.Q02
079200.Q01 061000.C03
072113.R01
(1/2" WIDE)
042000.D063
079200.Q02 089100.A01
072113.R01
079200.Q02
072113.R01
089100.A01
042000.D03C
2 1 /2"
3 1/2"
034500.A03
089100.A01 11
072113.R01
079200.Q02
051200.B03
089100.A01
089100.A01
P-F.1
054000.D04C
092900.B01C
089100.A01 1
P-F
079200.Q02
072713.A01
074213.A04C
1/2
1" 079200.Q01
1 089100.A01
051200.E01 4" X 4" X 1/2"
033100.A09
033100.A05
033100.V01
310000.A02 033100.V01
033100.J05 033100.B01
087100.S20
079200.Q01
042000.A01
042000.D06
042000.W01
034500.A03
079200.Q01
081113.D01
4"
079200.Q01
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE542
DO
OR
A
ND
LO
UV
ER
D
ET
AI
LS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
15"10"5"2"
3"=1'-0" GRAPHIC SCALE
01"
1 1/2" = 1'-0"
DOOR JAMB - EXTERIOR4
MATERIAL NOTES
033100.A05 CONCRETE FLOOR
033100.A09 CONCRETE FOUNDATION WALL
033100.B01 CONCRETE SLAB
033100.J05 PREFORMED JOINT FILLER
033100.V01 VAPOR BARRIER
034500.A03 PRECAST CONCRETE WALL
PANEL
042000.A01 MASONRY UNIT
042000.D03C CMU 8"
042000.D06 CMU LINTEL
042000.D07 CMU BULLNOSE
042000.W01 REINFORCING STEEL
051200.B03 STEEL TUBE COLUMN
051200.E01 STEEL ANGLE
054000.D04C STEEL STUD 4"
061000.C03 WOOD SHIM
072113.R01 BOARD THERMAL INSULATION
072713.A01 SELF-ADHERED MEMBRANE AIR
BARRIER
074213.A04C FACTORY INSULATED WALL
PANEL 2" THICK
079200.Q01 JOINT SEALANT
079200.Q02 BACKSTOP AND SEALANT
081113.D01 STEEL DOOR FRAME
081116.A01 GLAZED ALUMINUM STOREFRONT
SYSTEMS
087100.S20 THRESHOLD
089100.A01 EXTRUDED ALUMINUM WALL
LOUVER
092900.B01C GYPSUM BOARD, GLASS MAT
FACED 5/8"
310000.A02 FILL MATERIAL
3" = 1'-0"
LOUVER HEAD1
3" = 1'-0"
LOUVER JAMB END CONDITION2
3" = 1'-0"
LOUVER SILL AT WALL3 3" = 1'-0"
INTERMEDIATE JAMB6
3" = 1'-0"
LOUVER HEAD5
1 SEE LOUVER ELEVATIONS FOR LOUVER TYPES
2 STRUCTURAL SUPPORT FOR LOUVER
3 SEE STRUCTURAL DRAWINGS FOR REINFORCING
4 TRIM AND CLOSURE PIECES TO MATCH METAL
PANELS
5 COLUMN BEYOND
6 ALL STEEL SUPPORT FOR LOUVERS (EXCEPT
COLUMNS) SHALL BE REMOVEABLE TO ALLOW
REPLACEMENT OF MECHANICAL OR ELECTRICAL
EQUIPMENT
7 MATCH INTERIOR FRAME WIDTH
8 PRECAST LINTEL (NOTCHED) MAY ALSO BE USED TO
ALIGN WITH MASONRY COURSING.
9 CONT CLEAT. FASTEN 2" BELOW TO SLAB EDGE
10 SILL PAN WITH END DAMS AND BACK DAMS. FULLY
SEALED AND CORNERS SET IN FULL BEAD OF
SEALANT.
11 24 GA SS SHEET METAL SILL FLASHING TO SPAN
WALL CAVITY
12 CONT CLEAT
13 SEPARATION IS REQUIRED BETWEEN LOUVERS FOR
PROPER ATTACHMENT OF MECHANICAL EQUIPMENT
14 RECESSED FLOOR MAT
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. DIMENSIONS ARE TO COLUMN GRID, FACE OF
MASONRY/ CONCRETE/PRECAST, FACE OF METAL
STUD
C. ALL ACT THIS BUILDING 9'-0" AFF UON.
D. ALL GYP BD. CEILINGS AND SOFFITS THIS BUILDING
8'-6" AFF UON.
E. SEE SHEET H-AE521 FOR TYPICAL SEALANT AND
DRAIN INSTALLATION REQUIRED ON ALL PRECAST
PANELS
30"20"10"2"0
1 1/2"=1'-0" GRAPHIC SCALE
2"
3" = 1'-0"
LOUVER SILL AT FLOOR7
3" = 1'-0"
DOOR SILL8
3" = 1'-0"
EXTERIOR DOOR HEAD9
SY
M
D
ES
C R
IP
TI
O N
D
DOOR SCHEDULE REMARKS
1. OVERHEAD COILING DOOR, POWER OPERATED.
2. EXIT DEVICE REQUIRED (PANIC HARDWARE)
3. HEAVY DUTY DOOR
4. MAXIMUM DUTY DOOR
G50
8'
- 0
9' - 4"
055013.K02 5
L50 L53L52
7' - 4"
0" 2'
- 0
8' - 0"
14' - 4".
089100.A01 089100.A01 089100.A01
7' - 2".7' - 2".
4'
- 0
8'
- 0
6'
- 0
8'
- 0
2'
- 0
2'
- 0
8'
- 0
4'
- 0
2 2
P-AE542
P-AE542
P-AE542
P-AE542
P-AE542
P-AE542
P-AE542
P-AE542
P-AE542
L51
6' - 4"
089100.A01
3'
- 4
P-AE542
P-AE542
L54
1' - 4"
089100.A01
8 8
1'
- 4
"18
0"
P-AE542
S51
5' - 10"
WIDTH
DOOR
HE
IG
HT
DO
OR
3'
- 4
3'
- 8
081116.A01 5
9'
- 0
088100.A22
088100.A22
ALL EXTERIOR GLASS COLOR EGL-1
B50 B51
084423.A01081113.D04
3'
- 4
3'
- 4
2"4' - 0"2"
2" 3'
- 8
2"
2" 3'
- 8
2"
2" 6' - 0"2"
P-AE541
P-AE541
P-AE541
P-AE541
P-AE541
P-AE541088100.A12088100.A04
SINGLE
PAIR
FRAME W/ SIDELITE
2"
DO
OR
H
EI
GH
T
2"
WIDTH
DOOR2"
2"
DO
OR
H
EI
GH
T
2"DOOR WIDTHS2"
2"
DO
OR
H
EI
GH
T
2"3' - 0"2"
DOOR WIDTH
2"
088100.A04
F G FG
(FLUSH) (HALF GLASS) (FULL GLASS)
OHC
(OVERHEAD COILING)
N
(NARROW GLASS)
6" 6" 6" 6" 8"8"8"8"
6" 3'
- 0
6" 8"
8" 3'
- 0
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1/ 4"
1'
-0
P-AE601
DO
OR
S
CH
ED
UL
E
MN
H
De sig ne r
RL
B
P-
AE
DOOR SCHEDULE
DOOR NO
DOOR FRAME
RATING
(MIN)
HDWR
SET
DETAILS
REMARKS
TYP
E WIDTH HEIGHT MATERIAL TYPE MATERIAL TYPE HEAD JAMB
P1100.1 Pr 3' - 0" 8' - 0" HM F HM 2 90 18 9/P-AE542 9/P-AE541 4, SILL 4/P-AE527
P1100.2 3' - 0" 8' - 0" HM F HM 1 15 9/P-AE542 9/P-AE541 4, SILL 4/P-AE527
P1100.3 10' - 0" 14' - 0" STL OHC STL - 19 1/-P-AE541 3/P-AE541 1, SILL 2/P-AE541 P1101.1 Pr 3' - 0" 8' - 0" HM F HM 2 1 9/P-AE542 9/P-AE541 4, SILL 4/P-AE527 P1102.1 Pr 3' - 0" 8' - 0" HM F HM 2 237 4/P-AE541 5/P-AE541 3
P1102.2 10' - 0" 14' - 0" STL OHC STL - 149 1/-P-AE541 3/P-AE541 SILL 2/P-AE541
P1103 3' - 6" 8' - 0" HM F HM 1 90 15 9/P-AE542 9/P-AE541 4, SILL 4/P-AE527
P1104 3' - 6" 8' - 0" HM F HM 1 90 15 9/P-AE542 9/P-AE541 4, SILL 4/P-AE527
P1105.1 Pr 4' - 0" 8' - 0" HM F HM 2 238 4/P-AE541 5/P-AE541 3
P1105.2 4' - 0" 8' - 0" HM F HM 1 20 9/P-AE542 9/P-AE541 4, SILL 4/P-AE527
P1105.3 7' - 0" 10' - 0" STL OHC STL - 19 1/-P-AE541 SIM 3/P-AE541 SIM 1, SILL 2/P-AE541 P1105.4 7' - 0" 10' - 0" STL OHC STL - 19 1/-P-AE541 SIM 3/P-AE541 SIM 1, SILL 2/P-AE541 P1105.5 7' - 0" 10' - 0" STL OHC STL - 19 1/-P-AE541 SIM 3/P-AE541 SIM 1, SILL 2/P-AE541 P1105.6 7' - 0" 10' - 0" STL OHC STL - 19 1/-P-AE541 SIM 3/P-AE541 SIM 1, SILL 2/P-AE541
P1105.7 4' - 0" 8' - 0" HM F HM 1 20 9/P-AE542 9/P-AE541 4, SILL 4/P-AE527
P1110 3' - 0" 8' - 0" HM F HM 1 236 4/P-AE541 5/P-AE541 3
P1111 3' - 0" 8' - 0" HM F HM 1 236 4/P-AE541 5/P-AE541
P1112 3' - 0" 8' - 0" HM F HM 1 241 4/P-AE541 5/P-AE541 3
P1113 3' - 0" 8' - 0" HM G HM 1 243 4/P-AE541 5/P-AE541 3
P1114.1 3' - 0" 8' - 0" HM G HM 1 244 4/P-AE541 5/P-AE541
P1114.2 3' - 0" 8' - 0" HM F HM 1 244 4/P-AE541 5/P-AE541
P1115 3' - 0" 8' - 0" HM G HM 1 244 4/P-AE541 5/P-AE541
P1116 3' - 0" 8' - 0" HM F HM 1 245 4/P-AE541 5/P-AE541
P1118 3' - 6" 8' - 0" HM F HM 1 242 4/P-AE541 5/P-AE541 3
P1119 3' - 0" 8' - 0" HM F HM 7 246 4/P-AE541 5/P-AE541
P1120 3' - 0" 8' - 0" HM F HM 7 246 4/P-AE541 5/P-AE541
P1130.1 3' - 4" 9' - 0" AL FG AL S51 21 3/P-AE511 4/P-AE542 SILL 8/P-AE542
P1130.2 3' - 4" 9' - 0" AL FG AL S51 21 3/P-AE511 4/P-AE542 SILL 8/P-AE542
P1131.1 3' - 0" 8' - 0" HM F HM 1 90 240 4/P-AE541 5/P-AE541 2, 3
P1131.2 Pr 3' - 0" 8' - 0" HM F HM 2 1 9/P-AE542 9/P-AE541 2,4, SILL 4/P-AE527
P1131.3 3' - 0" 8' - 0" HM F HM 1 90 239 4/P-AE541 5/P-AE541 2, 3
P1132.1 3' - 0" 8' - 0" HM F HM 1 90 240 4/P-AE541 5/P-AE541 2, 3
P1132.2 Pr 3' - 0" 8' - 0" HM F HM 2 1 9/P-AE542 9/P-AE541 2, 4, SILL 4/P-AE527
P1133.1 3' - 0" 8' - 0" HM F HM 1 90 239 4/P-AE541 5/P-AE541 2, 3
P1133.2 Pr 3' - 0" 8' - 0" HM F HM 2 1 9/P-AE542 9/P-AE541 2,4, SILL 4/P-AE527
P1134.1 3' - 0" 8' - 0" HM F HM 1 90 239 4/P-AE541 5/P-AE541 2, 3
P1134.2 3' - 0" 8' - 0" HM F HM 1 90 239 4/P-AE541 5/P-AE541 2, 3
P1134.3 Pr 3' - 0" 8' - 0" HM F HM 2 1 9/P-AE542 9/P-AE541 2, 4, SILL 4/P-AE527
P1135 3' - 0" 8' - 0" HM F HM 1 22 4/P-AE525 10/P-AE541 4, SILL 8/P-AE542
P1140 Pr 3' - 0" 8' - 0" HM N HM 2 18 4/P-AE525 SIM 10/P-AE541 4, SILL 8/P-AE542
P1141 4' - 0" 8' - 0" HM F HM 1 45 239 4/P-AE541 5/P-AE541 2, 3
P1142 Pr 3' - 0" 8' - 0" HM N HM 2 18 4/P-AE525 SIM 10/P-AE541 4, SILL 8/P-AE542
A. REFER TO SHEETS GI009 AND GI010 FOR GENERAL
ABBREVIATIONS AND ARCHITECTURAL SYMBOLS.
B. PROVIDE 1/2" UNDERCUT FOR ALL INTERIOR DOORS
C. DOOR HARDWARE SETS FOR WOOD AND METAL
DOORS ARE SPECIFIED IN SECTION 087100
D. DOOR HARDWARE SETS FOR ALUMINUM/ GLASS
DOORS ARE SPECIFIED IN SECTION 087100
E. ALUMINUM FRAME PROFILES ARE GENERIC, REFER
TO SPECIFICATIONS FOR PERFORMANCE
REQUIREMENTS
F. HOLLOW METAL FRAME PROFILES ARE GENERIC,
REFER TO SPECIFICATIONS FOR PERFORMANCE
REQUIREMENTS
G. DOOR AND WINDOW DIMENSIONS GIVEN ARE
NOMINAL. FRAMING ROUGH OPENING SIZES TO BE
COORDINATED.
H. ALL EXTERIOR GLAZING SHALL BE LOW-E COATED,
INSULATED, LAMINATED, UON, SEE EXTERIOR
BUILDING ELEVATIONS FOR COLOR LOCATIONS
I. ALL EXTERIOR DOOR GLAZING SHALL BE GREEN
TINTED, LAMINATED GLASS TO MATCH MAIN
GLAZING.
J. ALL EXTERIOR WINDOW AND STOREFRONT FRAMES
SHALL HAVE 2 COAT FINISH.
K. ALL INTERIOR BORROWED LITE GLAZING IS CLEAR,
TEMPERED GLASS (088100.C02) UON
L. OPTIONAL NOTCHED PRECAST LINTEL WITH 2"
RECESS ABOVE DOORS IN MASONRY WALLS MAY
BE USED TO ACCOMODATE MASONRY DIMENSIONS.
M. ALL HOLLOW METAL FRAMES AND DOORS IN THIS
BUILDING ARE GALVANIZED
1/4" = 1'-0"
GATE ELEVATIONS5 1/4" = 1'-0"
LOUVER ELEVATIONS FOR BUILDING P1
1/4" = 1'-0"
STOREFRONT (TYPE S)6
1/4" = 1'-0"
BORROWED LITE ELEVATIONS FOR
BUILDING P4
1/4"=1'-0" GRAPHIC SCALE
15'10'5'1'01'
1 2-HOUR FRAME AND GLAZING
2 PROVIDE STEEL SUPPORT BEHIND ALL LOUVER
PANEL JOINTS AND MULLIONS.
4 ALIGN JOINTS WITH SURROUNDING METAL PANEL
JOINTS OR PRECAST REVEALS
5 FACTORY APPLIED FINISH, SEE SPECIFICATIONS.
6 4X4 TUBE
7 1 " SQUARE PICKETS AT 4" OC
8 ALIGN WITH TOP OF DOORS
9 SEPARATION IS REQUIRED BETWEEN SIDES OF
LOUVERS FOR PROPER ATTACHMENT OF
MECHANICAL EQUIPMENT. SEE 6/P-AE542
10 PROVIDE INSULATED R-10 METAL BLANK-OFF PANELS
PER MANUFACTURER STANDARD IN AREAS NOT USED
BY MECHANICAL DUCTS. REFER TO MECHANICAL
DRAWINGS FOR LOCATION OF BLANK-OFF PANELS.
SEE ALSO ARCHITECTURE DETAIL 9B/H-AE502 SIM.
MATERIAL NOTES
055013.K02 ALUMINUM GATE
081113.D04 STEEL GLAZED OPENING FRAME
081116.A01 GLAZED ALUMINUM
STOREFRONT SYSTEMS
084423.A01 GLAZED STEEL CURTAIN WALL
088100.A04 CLEAR TEMPERED GLASS
088100.A12 FIRE-RATED SAFETY GLASS
088100.A22 INSULATING-LAMINATED GLASS
UNIT
089100.A01 EXTRUDED ALUMINUM WALL
LOUVER
1/4" = 1'-0"
DOOR FRAME ELEVATIONS2
1/4" = 1'-0"
DOOR PANEL ELEVATIONS3
SY
M
D
ES
C R
IP
TI
O N
D
FF
0' - 0"
P-AP-BP-CP-DP-EP-F.1
PC-224
PC-214
PC212A
PC-222C
PC-205
PC-218PC-225
PC-215
PC-213
PC-215
PC-213
PC-215
PC-225PC-220A
PC-209PC-212
PC-222C
PC-212
PC-222APC-222PC-222PC-222PC-222
PC-211
PC-222
PC-211FPC-211 PC-208A PC-208PC-227
PC-233 PC-219
PC-206
PC-219
PC-215
PC-220PC-220
PC-204
PC-229
PC-211C
PC-230
PC-206PC-201
PC-201
P-F
TO PRECAST
24' - 0"
PANEL JOINT
14' - 0"
FF
0' - 0"
P-1 P-3 P-4P-0.5
PC-221
PC-210
PC-222C
PC-212
PC-222 PC-222 PC-222 PC-222
PC-211 PC-211F PC-211 PC-211
PC-222D
PC-212
PC-222
PC-211D
PC-223
PC-211E
PC-202
PC-228PC-238 PC-238 PC-238 PC-238 PC-238
P-2
FF
0' - 0"
P-A P-B P-C P-D P-E P-F.1
PC-212
PC-222C PC-222 PC-222 PC-222 PC-222 PC-222B
PC-211F PC-212PC-212
PC-222A
PC-211
PC-222
PC-211
PC-222
PC-212
PC-222CPC-222PC-222
PC-212A
PC-222C
PC-212
PC-222APC-222PC-222
PC-203
PC-217
PC-212
PC-222A
PC-211F PC-211 PC-211
PC-204
PC-229PC-231
PC-216PC-236
PC-231
PC-216
PC-211A
PC-227
PC-233
PC-201
PC-201
PC-211A
P-F
A
A
RECESSED PANEL EPC-2
PRECAST PANEL LEGEND
PANEL EPC-1
SEE PANEL ELEVATIONS FOR DIMENSIONS
SEE ELEVATIONS FOR COLORS
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
3/
1'
-0
P-AE701
PR
EC
AS
T
BU
ILD
IN
G
EL
EV
AT
IO
NS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
3/32" = 1'-0"
EAST ELEVATION1
3/32" = 1'-0"
NORTH ELEVATION2
A. FIELD VERIFY ALL PANEL SIZES PRIOR TO
FABRICATION
B. ALL HORIZONTAL PANEL DIMENSIONS ARE FROM
CENTER OF JOINT (REVEAL)
C. THESE ELEVATIONS ARE FOR REFERENCE ONLY.
DO NOT USE AS SHOP DRAWINGS.
D. PORTIONS OF THE BUILDING REMOVED FOR PANEL
CLARITY.
E. COORDINATE WITH ARCHITECTURAL AND
ENGINEERING DRAWINGS FOR DOORS, WINDOWS,
LOUVERS, MASONRY OPENINGS, PIPE
PENETRATIONS, ETC. NOT ALL OPENINGS ARE
SHOWN.
F. COORDINATE EXACT DIMENSION FROM TOP OF
FOOTING TO FINISHED FLOOR
3/32" = 1'-0"
WEST ELEVATION3
1 SEE P-AE403 FOR CONNECTOR CANOPY PRECAST
2 AROUND CORNER
3 SEE BUILDING ELEVATIONS FOR SCUPPER
LOCATIONS. CENTER IN PANEL
4 OPENING FOR MECHANICAL PIPING. APROX 3'-0" X
6'-0"
3/32"=1'-0" GRAPHIC SCALE
18'10'2'01' 42'26'
SY
M
D E S
C R
IP
TI
O N
D
FF
0' - 0"
P-BP-C
PC-238 PC-238 PC-238PC-238PC-238PC-238PC-238
FF
0' - 0"
P-1P-3P-4 P-0.5
PC-235
PC-235
PC-235
PC-237
PC-234
PC-238PC-238PC-238PC-238PC-238PC-238A
PC-232A
PC-226A PC-226
PC-232
1 1
P-2 P-0.1P-0.3 P-0.2P-0.4
RECESSED PANEL EPC-2
PRECAST PANEL LEGEND
PANEL EPC-1
SEE PANEL ELEVATIONS FOR DIMENSIONS
SEE ELEVATIONS FOR COLORS
P-0.1 P-0.3P-0.2
PC-300 PC-300 PC-301 PC-300 PC-300
PC-303PC-303
PC-302
PC-302
P-0.4
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
3/
1'
-0
P-AE702
PR
EC
AS
T
BU
ILD
IN
G
EL
EV
AT
IO
NS
Au tho r
De sig ne r
Ch ec ke r
P-
AE
3/32" = 1'-0"
PRECAST ELEVATION - YARD - EAST2
A. FIELD VERIFY ALL PANEL SIZES PRIOR TO
FABRICATION
B. ALL HORIZONTAL PANEL DIMENSIONS ARE FROM
CENTER OF JOINT (REVEAL)
C. THESE ELEVATIONS ARE FOR REFERENCE ONLY.
DO NOT USE AS SHOP DRAWINGS.
D. PORTIONS OF THE BUILDING REMOVED FOR PANEL
CLARITY.
E. COORDINATE WITH ARCHITECTURAL AND
ENGINEERING DRAWINGS FOR DOORS, WINDOWS,
LOUVERS, MASONRY OPENINGS, PIPE
PENETRATIONS, ETC. NOT ALL OPENINGS ARE
SHOWN.
F. COORDINATE EXACT DIMENSION FROM TOP OF
FOOTING TO FINISHED FLOOR
3/32" = 1'-0"
SOUTH ELEVATION1
1 AROUND CORNER
2 SOLID CORNER SHAPE
3/32"=1'-0" GRAPHIC SCALE
18'10'2'01' 42'26'
3/32" = 1'-0"
PRECAST ELEVATION -PUMP HOUSE3
TYPICAL OF FOUR ELEVATIONS
SY
M
D E S
C R
IP
TI
O N
D
3' - 7 1/2"
8'
- 0
2'
- 0
0"
OPENING
PC-201 PC-202 PC-203 PC-204 PC-205 PC-206
4' - 2"
0" 2'
- 0
0"
4' - 6"
0" 2'
- 0
0"
5' - 9"
0"
7' - 9 1/2" 8' - 0 1/2"
0" 2'
- 0
0"
0" 2'
- 0
0"OPENING
2 2 2
EQ EQ
PC-208
OPENING
8' - 8"
0" 2'
- 0
0"
8' - 8"
0" 2'
- 0
0"
0" 2'
- 0
0"
9' - 1"
0" 2'
- 0
0"
10' - 0"
PC-209 PC-210 PC-211
2 2 2 2
PC-208A (OH) PC-211A, PC-211B, PC-211C,
PC-211D, PC-211E, PC-211F
(OPENINGS VARY)
PC-213
10' - 0"
0" 2'
- 0
0"
PC-212
11' - 8"
2'
- 0
6'
- 0
2'
- 0
0"
11' - 11"
11' - 7 1/2"11' - 3 1/2"
0" 2'
- 0
0"
0" 2'
- 0
0"
0" 2'
- 0
0"
PC-214 PC-215 PC-216
OPENING
OPENING
EQ EQ
EQ EQ
(PANEL CONFIGURATION MAY BE MODIFIED FOR SHIPPING.)
PC-207
9' - 11"
2'
- 0
2'
- 8
2'
- 1
5'
- 3
2'
- 0
0"
2 TYP
RECESSED PANEL EPC-2
PRECAST PANEL LEGEND
PANEL EPC-1
SEE PANEL ELEVATIONS FOR DIMENSIONS
SEE ELEVATIONS FOR COLORS
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE703
PR
EC
AS
T
PA
NE
L E
LE
VA
TI
ON
S
Au tho r
De sig ne r
Ch ec ke r
P-
AE
A. FIELD VERIFY ALL PANEL SIZES PRIOR TO
FABRICATION
B. ALL HORIZONTAL PANEL DIMENSIONS ARE FROM
CENTER OF JOINT (REVEAL)
C. THESE ELEVATIONS ARE FOR REFERENCE ONLY.
DO NOT USE AS SHOP DRAWINGS.
D. PORTIONS OF THE BUILDING REMOVED FOR PANEL
CLARITY.
E. COORDINATE WITH ARCHITECTURAL AND
ENGINEERING DRAWINGS FOR DOORS, WINDOWS,
LOUVERS, MASONRY OPENINGS, PIPE
PENETRATIONS, ETC. NOT ALL OPENINGS ARE
SHOWN.
F. COORDINATE EXACT DIMENSION FROM TOP OF
FOOTING TO FINISHED FLOOR
1/4"=1'-0" GRAPHIC SCALE
15'10'5'1'01'
1/4" = 1'-0"
PRECAST PANEL ELEVATIONS1
1 FINISHED FLOOR
2 REVEAL SEE 6/P-AE501
SY
M
D E S
C R
IP
TI
O N
D
4' - 11 1/2"
2'
- 0
6'
- 0
2'
- 0
0"
8' - 0 1/2"
2'
- 0
6'
- 0
2'
- 0
0"
2'
- 0
6'
- 0
2'
- 0
0"
8' - 8" 9' - 1"
2'
- 0
6'
- 0
2'
- 0
0"
10' - 0"
2'
- 0
6'
- 0
2'
- 0
0"
PC-222
PC-221PC-220PC-219PC-217
2 2 2 2 2 2
PC-218
2'
- 0
6'
- 0
2'
- 0
7' - 9 1/2"
PC-220A (SCUPPER)
PC-222A, 222B, 222C, 222D
10' - 8"
2'
- 0
6'
- 0
2'
- 0
0"
2'
- 0
6'
- 0
2'
- 0
0"
11' - 3 1/2" 11' - 7 1/2"
2'
- 0
6'
- 0
2'
- 0
0"
PC-223 PC-224 PC-225
2 2 2
4' - 2"
1'
- 0
6'
- 0
2'
- 0
9'
- 0
5' - 9"
1'
- 0
6'
- 0
2'
- 0
9'
- 0
10' - 0"
1'
- 0
6'
- 0
2'
- 0
9'
- 0
11' - 11"
1'
- 0
6'
- 0
2'
- 0
9'
- 0
PC-231PC-230PC-229PC-228
OPENING
2 2 2
EQ EQ
4' - 1"
PC-237
75°
PC-237 PANEL SECTION
4 1
/4" 2'
- 0 1/
4" 6'
- 3 1/
2" 2'
- 0 1/
4"
9' - 10"
2'
- 0
6'
- 0
2'
- 0
0"
15' - 3 1/2"
2'
- 0
6'
- 0
2'
- 0
0"
PC-232 PC-233
2 215° 15°
PC-232A (OH) PC-233A (OH)
7' - 2"
0" 2'
- 0
0"
12' - 7"
0" 2'
- 0
0"
PC-227PC-226
12 215° 15°
PC-226A (OH)
4' - 1" 9' - 0 1/2"
0" 2'
- 0
0"
PC-235PC-234
2 2
10' - 0"
PC-236
0" 2'
- 0
0"
75°
PC-234 PANEL SECTION
5 3 /4"
1'
- 1
1 3 /4"
4 1 /2"
9' - 9"
2'
- 0
2'
- 8
2'
- 1
5'
- 3
2'
- 0
0"
2' - 2 1/2"1' - 7"2' - 2"1' - 7"2' - 2 1/2"
PC-238
RE
CE
SS
RECESS
RE
CE
SS
RECESS
2 TYP
8'
- 6
1/ 2"
1'
- 6
PC-238A (ADJUST PANEL WIDTH)
RECESSED PANEL EPC-2
PRECAST PANEL LEGEND
PANEL EPC-1
SEE PANEL ELEVATIONS FOR DIMENSIONS
SEE ELEVATIONS FOR COLORS
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
P-AE704
PR
EC
AS
T
PA
NE
L E
LE
VA
TI
ON
S
Au tho r
De sig ne r
Ch ec ke r
P-
AE
1/4"=1'-0" GRAPHIC SCALE
15'10'5'1'01'
A. FIELD VERIFY ALL PANEL SIZES PRIOR TO
FABRICATION
B. ALL HORIZONTAL PANEL DIMENSIONS ARE FROM
CENTER OF JOINT (REVEAL)
C. THESE ELEVATIONS ARE FOR REFERENCE ONLY.
DO NOT USE AS SHOP DRAWINGS.
D. PORTIONS OF THE BUILDING REMOVED FOR PANEL
CLARITY.
E. COORDINATE WITH ARCHITECTURAL AND
ENGINEERING DRAWINGS FOR DOORS, WINDOWS,
LOUVERS, MASONRY OPENINGS, PIPE
PENETRATIONS, ETC. NOT ALL OPENINGS ARE
SHOWN.
F. COORDINATE EXACT DIMENSION FROM TOP OF
FOOTING TO FINISHED FLOOR
1/4" = 1'-0"
PRECAST PANEL ELEVATIONS1
1 FINISHED FLOOR
2 REVEAL SEE 6/P-AE501
SY
M
D E S
C R
IP
TI
O N
D
PC-300 PC-301 PC-303
PC-302
7' - 0" 7' - 7"
5' - 7"
15°15°
5' - 1"
5 3/4"
1 1
2 2
EQ
EQ
EQ
EQ
EQ
16' - 7 1/2"
EQ
EQ
EQ
EQ
EQ
16' - 7 1/2"
8"
10"
PC-300 PC-301
EQ
EQ
EQ
EQ
EQ
7 3
/4"
7 1 /4"
75°
75°
3'
- 9
1/ 2"
3'
- 1
3/ 4"
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1/ 4"
1'
-0
P-AE705
PR
EC
AS
T
PA
NE
L E
LE
VA
TI
ON
S
Au tho r
De sig ne r
Ch ec ke r
P-
AE
A. FIELD VERIFY ALL PANEL SIZES PRIOR TO
FABRICATION
B. ALL HORIZONTAL PANEL DIMENSIONS ARE FROM
CENTER OF JOINT (REVEAL)
C. THESE ELEVATIONS ARE FOR REFERENCE ONLY.
DO NOT USE AS SHOP DRAWINGS.
D. PORTIONS OF THE BUILDING REMOVED FOR PANEL
CLARITY.
E. COORDINATE WITH ARCHITECTURAL AND
ENGINEERING DRAWINGS FOR DOORS, WINDOWS,
LOUVERS, MASONRY OPENINGS, PIPE
PENETRATIONS, ETC. NOT ALL OPENINGS ARE
SHOWN.
F. COORDINATE EXACT DIMENSION FROM TOP OF
FOOTING TO FINISHED FLOOR
1/4"=1'-0" GRAPHIC SCALE
15'10'5'1'01'
1 FINISHED FLOOR
2 REVEAL SEE 6/P-AE501
3 COORDINATE DIMENSION WITH
FOUNDATION PC-303
ISOMETRIC VIEW
SY
M
D E S
C R
IP
TI
O N
D
SHEET NOTES:
NOTES:
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
P-AF601
FI
NI
SH
S
CH
ED
UL
E
MT
I
MT
I
CM
E
P-
AF
A COLOR DESIGNATIONS SHALL BE AS INDICATED IN
SPECIFICATION SECTION 090690 COLOR
SCHEDULE
B REFER TO CEILING PLANS P-AE131 THROUGH
P-AE133 FOR FINISH LOCATIONS.
C ALL HOLLOW METAL DOORS AND FRAMES TO BE
PAINTED PT-4 UNLESS OTHERWISE NOTED.
D PAINT THE FRONT AND UNDERSIDE OF THE
CEILING THE SAME COLOR UNLESS OTHERWISE
NOTED.
E REFER TO DETAIL 5/H-IN213 FOR WALL TILE
PATTERN.
F REFER TO SPECIFICATION SECTION 09 06 90
COLOR SCHEDULE FOR LIST OF CASEWORK AND
MILLWORK FINISHES.
FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASE
WALLS
CEILING
FINISH
REMARKSNORTH EAST SOUTH WEST
P1100 HEATING EQUIPMENT CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1101 STORAGE CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1102 WATER TREAT CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1103 GAS CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1104 GAS CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1105 COOLING EQUIPMENT CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1110 STOCK STORAGE RT-2 RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1111 REPAIR PARTS RT-2 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 --- P1112 COMM EQ RT-2 RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1113 CORR RT-2 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 --- P1114 WORK/CONTROL RT-2 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 --- P1115 BREAK RT-2 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 --- P1116 TLT PFT-1 MT-2 / PWT-7 PWT-7 PWT-7 PWT-7 PWT-7 PT-1e 1 P1117 CORR RT-2 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 / PT-1b --- P1118 MECHANICAL CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1119 OFFICE CPT-1 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 --- P1120 PLANT MGR CPT-1 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 --- P1130 CORR RT-2/WM-1 RB-1 PT-2b PT-2b PT-2b PT-2b ACT-1 --- P1131 ATS CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1132 EMERGENCY POWER CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1133 NORMAL SOURCE CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1134 GENERATORS CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1135 FUEL PUMP CS RB-1 PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1140 DOMESTIC EQUIP CS -- PT-2b -- -- -- PT-1b 2 P1141 ELECT CS -- PT-2b PT-2b PT-2b PT-2b PT-1b 2 P1142 FIRE PUMP CS -- -- -- PT-2b PT-2b PT-1b 2
FINISH ABBREVIATIONS
ACT ACOUSTICAL CEILING TILE
CPT CARPET TILE
CS CONCRETE, SEALED
PFT PORCELAIN FLOOR TILE
PT PAINT
MT METAL TRIM
PWT PORCELAIN WALL TILE
RB RUBBER BASE
RT RUBBER TILE
WM WALK OFF MAT
a FLAT b EGGSHELL c SATIN d SEMI-GLOSS e EPOXY
FINISH REMARKS
1 USE ALL REQUIRED TRIM PIECES FOR A
COMPLETE INSTALLATION
2 PAINT EXPOSED STRUCTURE IN ALL
ROOMS WITHOUT CEILINGS
SY
M
D
ES
C R
IP
TI
O N
D
UP
HEATING
EQUIPMENT
P1100
STORAGE
P1101
WATER TREAT
P1102
GAS
P1103
GAS
P1104
COOLING
EQUIPMENT
P1105
COOLING
TOWER YARD
P1106
A1
A1
A1
A1
XBC
XBC XBC XBC
XBC
XBC
XBC
REF LINE
P-AG112
REF LINE
P-AG112
A1
A1
N
25'0 5' 15'
1/8"=1'-0" GRAPHIC SCALE
5'
KEY PLAN
P
SHEET NOTES:
NOTES:
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1/ 8"
1'
-0
P-AG111
SI
GN
AG
E
PL
AN
, L
EV
EL
1, Z
ON
E
AC
D
CM
E
CM
E
P-
AG
SIGN TYPES
A1 PRIMARY ROOM IDENTIFICATION
C1 RESTROOM IDENTIFICATION
H1 FACILITIES MANAGEMENT DOOR TAG
XBC EXTERIOR WALL MOUNTED ENTRANCE SIGN
A. SEE SHEET P-AG601 FOR SIGNAGE SCHEDULES
B. REFER TO SHEETS H-AG501 THROUGH H-AG511
FOR SIGN DETAIL ELEVATIONS AND MOUNTING
HEIGHTS
C. FACILITIES ENGINEER TO VERIFFY SIGN MESSAGE
SCHEDULE PRIOR TO FABRICATION.
D. VERIFY ROOM NUMBERING SYSTEM WITH
FACILITIES ENGINEER PRIOR TO FABRICATION
SY
M
D E S
C R
IP
TI
O N
D
EMERGENCY
POWER
P1132
PLANT MGR
P1120BREAK
P1115
STOCK
STORAGE
P1110
OFFICE
P1119
REPAIR PARTS
P1111 WORK /
CONTROL
P1114
NORMAL
SOURCE
P1133
GENERATORS
P1134
ATS
P1131
FUEL PUMP
P1135
MECHANICAL
P1118
CORR
P1130
CORR
P1113
CORR
P1117
COMM EQ
P1112
TLT/LKR
P1116
A1
A1 A1
A1
A1A1
A1 A1
A1 A1
XBC
XBC
XBC
XBC
XBC
XBC
XBC
C1
A1 A1
A1
A1
REF LINE
P-AG111 A1
A1
A1
A1
A1 A1
P1142
FIRE PUMP
P1140
DOMESTIC EQUIP
P1141
ELECT
XBC
A1
XBC
N
25'0 5' 15'
1/8"=1'-0" GRAPHIC SCALE
5'
KEY PLAN
P
SHEET NOTES:
NOTES:
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1/ 8"
1'
-0
P-AG112
SI
GN
AG
E
PL
AN
, L
EV
EL
1, Z
ON
E 2 &
AC
D
CM
E
CM
E
P-
AG
SIGN TYPES
A1 PRIMARY ROOM IDENTIFICATION
C1 RESTROOM IDENTIFICATION
H1 FACILITIES MANAGEMENT DOOR TAG
XBC EXTERIOR WALL MOUNTED ENTRANCE SIGN
A. SEE SHEET P-AG601 FOR SIGNAGE SCHEDULES
B. REFER TO SHEETS H-AG501 THROUGH H-AG511
FOR SIGN DETAIL ELEVATIONS AND MOUNTING
HEIGHTS
C. FACILITIES ENGINEER TO VERIFFY SIGN MESSAGE
SCHEDULE PRIOR TO FABRICATION.
D. VERIFY ROOM NUMBERING SYSTEM WITH
FACILITIES ENGINEER PRIOR TO FABRICATION
SY
M
D E S
C R
IP
TI
O N
D
SHEET NOTES:
NOTES:
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
P-AG601
SI
GN
AG
E
SC
HE
DU
LE
AC
D
CM
E
CM
E
P-
AG
A. REFER TO SHEETS P-AG111 AND
P-AG112 FOR SIGNAGE LOCATION
PLANS
B. REFER TO SHEETS H-AG501
THROUGH H-AG511 FOR SIGN DETAIL
ELEVATIONS AND MOUNTING
HEIGHTS
C. FACILITIES ENGINEER TO VERIFFY
SIGN MESSAGE SCHEDULE PRIOR TO
FABRICATION
D. VERIFY ROOM NUMBERING SYSTEM
WITH FACILITIES ENGINEER PRIOR
TO FABRICATION
ROOM ID SIGN SCHEDULE LEVEL 1-A1
ARCH
ROOM # ARCH ROOM NAME
SIGN
TYPE
SIGN
ROOM # SIGN MESSAGE 1
DOOR
TAG
FF
P1100 HEATING EQUIPMENT A1 P1100 HEATING EQUIPMENT P1100
P1100 HEATING EQUIPMENT A1 P1100…