Drwgs_Vol_6E_6shts_W912PL-12-R-0008.pdf
PDF 14 MB Posted
- Solicitation number
- W912PL-12-R-0008
About this file
Drawings - Volume 6E
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FACP/FMCP
FAAP RM 2134
FAPS-H2A
FAPS-H3A
FAPS-H1A
FAPS-H2B
FAPS-H3B
FAPS-H1B
RM 1112
RM 2115
RM 3121
RM 1212
RM 2206
RM 3222
SMOKE WALL
NAC-H3B
SERVES
ZONE 3B
NAC-HP
SERVES HOSPITAL
PENTHOUSE
NAC-H3A
DAL
H31LS1-
SLC-H3
SLC-H3
SLC-H3
SLC-H3 SLC-H3
DA
L
NAC-H2B
SERVES
ZONE 2B
SERVES
ZONE 2A
NAC-H2A
H21LS1-
SLC-H2
SLC-H2 SLC-H2
DAL
DA
L
DAL
SLC-H2
SLC-H2
RM 2301
H21LS1-
NAC-H1B
SERVES
ZONE 1B
H11LS1-
SLC-H1
DAL
NAC-H1A
SLC-H1
SLC-H1
SERVES
ZONE 1A
SLC-H1
SLC-H1
DAL
SERVES
ZONE 3A
H32LS1-
H22LS1-
SMOKE ZONE A SMOKE ZONE B
SLC-HP
SERVES HOSPITAL
PENTHOUSE
FAPS-C2
FAPS-C3
FAPS-C1
RM 1404
RM 2464
RM 3437
NAC-C3
SLC-C3
SLC-C3
DAL
NAC-C2
SLC-C2
SLC-C2
NAC-C1
SLC-C1
SLC-C1
SERVES 3RD
FLOOR
CLINIC
C34LS1-3
C15LS2-9
C24LS1-6
SERVES
2ND FLOOR
CLINIC
SERVES 1ST
FLOOR
CLINIC
SERVES 3RD
FLOOR
HOSPITAL
SERVES 2ND
FLOOR
HOSPITAL
DAL
DA
L
SLC-C2
DAL
SERVES 1ST
FLOOR
HOSPITAL
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
PENTHOUSE
ROOF
HOSPITAL CLINIC
SLC-CP
NAC-CP
SERVES CLINIC
PENTHOUSE
NAC-C1B SLC-C1NOTIFICATION APPLIANCE CIRCUIT (NAC) SIGNALING LINE CIRCUIT (SLC)
DAL DIGITAL AUDIO LOOP (DAL), 2 HOUR RATED
CABLE INSTALLED IN METAL CONDUIT
INDICATES FLOOR: 1-FIRST FLOOR,
2-SECOND FLOOR, 3-THIRD FLOOR,
P-PENTHOUSE
INDICATES OCCUPANCY: C-CLINIC,
H-HOSPITAL, P-CENTRAL UTILITY
PLANT
NOTIFICATION APPLIANCE CIRCUIT
INDICATES FLOOR: 1-FIRST FLOOR,
2-SECOND FLOOR, 3-THIRD FLOOR,
P-PENTHOUSE
INDICATES OCCUPANCY: C-CLINIC,
H-HOSPITAL, P-CENTRAL UTILITY
PLANT
SIGNALING LINE CIRCUIT
LINE CODE LEGEND
SLC-C3
INDICATES SMOKE ZONE WHERE
APPLICABLE
SLC-C1
SLC-CP
NAC-CP
SERVES CLINIC
PENTHOUSE
FAPS-P
NAC-P
SLC-P
PLS1B-17
SERVES CUP
SL
C-
P
DA
L
DA
L
CENTRAL UTILITY PLANT
RM P1112
SLC-C1 INDICATES TWO HOUR FIRE
RATED CABLE IN METAL
CONDUIT
H11LS1-
FAAP
RM 1548
SLC-H1BSLC-H1A
SLC-H2A
SLC-H3A
SLC-H2B
SLC-H3B
MNOC
MNOC
RM 1548
RM 2134
2 2
2 2
RADIO TRANSMITTER ANTENNA.
SEE 2/FA603 FOR DETAIL.
FARP
H21LS1-16
H21LS1-15
6 8
MNOC
MNOC
RM 11C03
RM 14C03
MNOC RM 2130
MNOC RM 2301
MNOC RM 24C01
MNOC RM 31C03
MNOC RM 33C08
25S01
34S01
SLC-C3
MNOC RM P1114
SHEET NOTES:
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
NO
S
CA
LE
FA601
TY
PI
CA
L F
IR
E
AL
AR
M
CO
NN
EC
TI
ON
D
IA
GR
AM
RL
W
RL
W
KL
M
FA
NO SCALE1 TYPICAL FIRE ALARM CONNECTION DIAGRAM
1 TYPICAL NOTIFICATION APPLIANCE
CIRCUIT(S) AS REQUIRED TO SERVE
SPEAKERS AND STROBES. SEE 2/FA602 FOR
CONNECTION DIAGRAM.
2 TYPICAL SIGNALING LINE CIRCUIT(S) AS
REQUIRED. SEE 2/FA602 FOR CONNECTION
DIAGRAM.
3 REMOTE POWER SUPPLY/AMPLIFIER
CABINET(S) CONSISTING OF DIGITAL AUDIO
AMPLIFIER, POWER SUPPLIES, BATTERIES
AND CONTROL MODULES. SEE 2/FA602 FOR
CONNECTION DIAGRAM.
4 3/4" CONDUIT WITH RADIO TRANSMITTER
ANTENNA WIRING AS REQUIRED.
5 ROUTE FIRE ALARM CIRCUITS THROUGH
MECHANICAL UTILITY CANOPY BETWEEN
BUILDINGS. PROVIDE SURGE PROTECTION
ON ALL CIRCUITS AT BOTH ENDS.
6 THE VOICE NOTIFICATION SYSTEM SHALL BE
INDEPENDANT OF THE FIRE ALARM SYSTEM
AND BE CAPABLE OF AUTONOMOUS
OPERATION. THE VOICE NOTIFICATION
SYSTEM SHALL BE HOUSED IN A SEPERATE
PANEL THAT CONTAINS AN INDEPENDANT
POWER SUPPLY AND BATTERIES. IT IS
SHOWN AS A SINGLE PANEL FOR CLARITY
ONLY.
7 ONE CIRCUIT SHALL SERVE THE FIRE ALARM
CONTROL PANEL/MASS NOTIFICATION
CONTROL PANEL AND THE OTHER CIRCUIT
SHALL SERVE THE VOICE NOTIFICATION
SYSTEM PANEL POWER SUPPLIES.
8 PROVIDE WITH BATTERY BACK-UP AS
DESCRIBED IN SPECIFICATIONS SECTION
283176, PARAGRAPH 2.13.
A.
B.
C.
INSTALL ALL FIRE ALARM SYSTEM WIRING IN
3/4" CONDUIT UNLESS NOTED OTHERWISE.
CONDUIT SIZES AND QUANTITIES ARE SHOWN
FOR BIDDING PURPOSES ONLY. PROVIDE
CONDUIT SIZES, QUANTITES AND
CONFIGURATION IN ACCORDANCE WITH THE
MANUFACTURERS APPROVED SHOP
DRAWINGS.
HOSPITAL PORTION OF THE FIRE ALARM
SYSTEM SHALL BE A SURVIVABLE LEVEL 3
CABLE SYSTEM INSTALLED IN METAL CONDUIT.
SY
M
D E S
C R
IP
TI
O N
D
AT
E
FIRE ALARM SYSTEM MONITOR
MODULE FOR SUPERVISION OF
120V CONTROL CIRCUIT SERVING
THE ELEVATOR SHUNT TRIP
DEVICE. UPON LOSS OF POWER
AT THE CONTROL RELAY "FR", A
SUPERVISORY SIGNAL SHALL
ANNUNCIATE AT THE FIRE ALARM
CONTROL PANEL AND REMOTE
ANNUNCIATOR. MOUNT WITHIN
36" OF THE ELEVATOR
DISCONNECT.
FIRE ALARM CONTROL MODULE WITH FORM C
ADDRESSABLE RELAY AND CONTACTS RATED
FOR 5A, 120VAC. MOUNT IN A 4" SQUARE BOX
AND PROVIDE SOLID BARRIER TO SEPARATE
THE POWER LIMITED AND NON POWER
LIMITED WIRING. CONTACT SHALL CLOSE
UPON ACTIVATION OF DEVICES AS INDICATED
ON THE FIRE ALARM SEQUENCE OF
OPERATION. MOUNT WITHIN 36" OF THE
ELEVATOR CONTROL SWITCH. FIRE ALARM SIGNALING
LINE CIRCUIT.
MAIN DISCONNECT
ST
ST
ST
SHUNT TRIP
FUSES
PL
FR
ST
CR
KEY TEST SWITCH
LINE LOAD
FUSE FUSE
FUSE
CONTROL POWER
TRANSFORMERUL LISTED ELEVATOR CONTROL SWITCH WITH
FUSED PROTECTION FOR ELEVATOR AND SHUNT
TRIP MECHANISM. PROVIDE INTEGRAL 480V-120V
CONTROL POWER TRANSFORMER, KEY OPERATED
TEST SWITCH, FIRE SAFETY INTERFACE RELAY "CR"
(FOR ACTIVATION OF THE SHUNT TRIP FROM THE
FIRE ALARM SYSTEM), RED PILOT LIGHT "PL" (FOR
POWER "ON" INDICATION), AND SHUNT TRIP
VOLTAGE MONITORING RELAY "FR" (FOR
MONITORING OF THE SHUNT TRIP CIRCUIT FROM THE
FIRE ALARM SYSTEM). UNIT SHALL HAVE A 200,000A
SHORT CIRCUIT RATING. PROVIDE MAIN FUSES IN
ACCORDANCE WITH THE ELEVATOR MANUFACTURES
RECOMMENDATIONS.
FR
FA
LEGEND
PILOT LIGHT TO VISUALLY INDICATE PRESENCE OF CONTROL
VOLTAGE.
SHUNT TRIP VOLTAGE MONITORING RELAY.
SHUNT TRIP COIL.
CONTROL RELAY TO ISOLATE THE FIRE ALARM CONTACTS "FA"
FROM THE SHUNT TRIP COIL DUTY.
CR
PL
FR
ST
CR
P
AOM
DH
AIM
TS
AIM
FS
AOM
AHU1.1
ST-AHU1.1
AOM
VFD1
VFD
VFD1
6SIGNALING LINE CIRCUIT (SLC)
AOMEL
INSTALL ALL WIRING IN 3/4" CONDUIT UNLESS OTHERWISE NOTED.
AOM
AOM
AOM
AD
AOM
DL
AIM
EL
EL4
FACP NOTE:
DH
AOMAIMAOMAIM
TS
PIV
AOM
FAPS
NOTIFICATION APPLIANCE
CIRCUIT (NAC)
AOM
AIM
THE DESIGNATED LEVEL FOR ELEVATOR RECALL SHALL BE LEVEL 2. ALTERNATE LEVEL #1 SHALL BE LEVEL 1. ALTERNATE LEVEL #2 SHALL BE LEVEL 3. ALTERNATE LEVEL #3 SHALL BE LEVEL 4 FOR ELEVATOR 8 ONLY. WHERE AN INITIATING DEVICE ACTIVATES ELEVATOR RECALL, THE ELEVATOR SHALL RECALL TO THE DESIGNATED LEVEL. IF THE DESIGNATED LEVEL LOBBY SMOKE DETECTOR IS IN ALARM, THEN THE ELEVATOR
SHALL RECALL TO THE NEXT AVAILABLE ALTERNATE LEVEL NOT IN ALARM.
DEFINITIONS:
DESIGNATED LEVEL – THE PRIMARY LEVEL OF RECALL FOR FIREFIGHTERS’ SERVICE AS DESCRIBED IN NFPA 72, CHAPTER 21.3.
ALTERNATE LEVEL – A LEVEL OTHER THAN THE DESIGNATED LEVEL AS DESCRIBED IN NFPA 72, CHAPTER 21.3.
ELEVATOR RECALL PRIORITY
TYP. SPEAKER IN
STAIRWELL
NOTIFICATION APPLIANCE
CIRCUIT (NAC)
TYP. JUNTION BOX
LOCATED IN ELEVATOR
MACHINE ROOM
ELEVATOR TRAVELING CABLE
E TYP. ELEVATOR CAB
SPEAKER
AOM
AIM
FM-200
FM-200
AIM
38 40
AOM
FCU/FDDC
H1KLQ1C-24
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ1C-15
NOTE: ALL SHUNT TRIP WIRING SHALL BE #12 AWG. PROVIDE WIRING IN 1/2" CONDUIT.
FIRE ALARM CONTROL
MODULE CONTACT
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ1C-19
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ1C-23
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ1C-16
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ1C-20
H1KLQ2C-35
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ2C-3
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ2C-7
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ2C-11
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ2C-6
C
SHUNT TRIP COIL,
CIRCUIT H1KLQ2C-10
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
FIRE ALARM CONTROL
MODULE CONTACT
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
NO
T
TO
S
CA
LE
FA602
TY
PI
CA
L F
IR
E
AL
AR
M
DE
VI
CE
C
ON
NE
CT
IO
N
DI
AG
RA
M
RL
W
RL
W
KL
M
FA
NTS1 ELEVATOR SHUTDOWN INTERFACE DIAGRAM
19 PROVIDE MONITOR MODULES FIRE PUMP
ALARM SIGNALS AS INDICATED ON THE FIRE
ALARM SEQUENCE OF OPERATION MATRIX.
PROVIDE QUANTITY AS REQUIRED. MOUNT
MODULE WITHIN 36" OF FIRE PUMP
CONTROL PANEL. REFER TO SHEET FA604
AND FA605 FOR FIRE ALARM SYSTEM
SEQUENCE OF OPERATION MATRIX.
20 TYPICAL DOOR ACCESS CONTROL SYSTEM
EQUIPMENT CABINET.
21 CONTROL MODULE FOR DEACTIVATION OF
DOOR LOCKS IN EGRESS PATHS. MODULE
SHALL BE LOCATED WITHIN 36" OF ACCESS
CONTROL SYSTEM EQUIPMENT CABINET.
22 TYPICAL CONNECTION TO KITCHEN
EQUIPMENT GAS SUPPLY SOLENOID VALVE.
MOUNT WITHIN 36" OF DEVICE IT SERVES.
23 CONTROL MODULE FOR SHUT-OFF OF GAS
SUPPLY TO KITCHEN EQUIPMENT.
24 TYPICAL CONNECTION TO KITCHEN HOOD
FIRE SUPPRESSION SYSTEM.
25 LOCATE MONITOR MODULE WITHIN 36" OF
KITCHEN HOOD WHICH IT SERVES.
26 TYPICAL CONNECTION TO SHUNT TRIP COIL
IN CIRCUIT BREAKER SERVING KITCHEN
EQUIPMENT.
27 CONTROL MODULE FOR ACTIVATION OF
SHUNT TRIP COIL IN CIRCUIT BREAKER
SERVING KITCHEN EQUIPMENT. MOUNT
WITHIN 36" OF DEVICE IT SERVES.
28 CONTROL MODULE FOR INTERFACE WITH
THE DATA CENTER MASTER CONTROL
PANEL. MOUNT WITHIN 36" OF CONTROL
PANEL.
29 DATA CENTER COMPUTER ROOM AIR
CONDITIONING UNIT (CAC) MASTER
CONTROL PANEL.
30 TYPICAL HVAC SYSTEM "DDC" PANEL.
31 CONTROL MODULE FOR FIRE ALARM
INTERFACE WITH HVAC CONTROL SYSTEM.
PROVIDE A CONTROL MODULE FOR EACH
HVAC SYSTEM CONTROL PANEL. THE
CONTROL MODULE SHALL ALERT THE HVAC
CONTROL SYSTEM OF A FIRE ALARM FAN
SHUT-DOWN EVENT. MOUNT MODULE
WITHIN 36" OF HVAC CONTROL PANEL.
32 FIRE PUMP CONTROL PANEL.
33 REFER TO P-FA112 FOR LOCATION.
34 CONTROL MODULE FOR ACTIVATION OF
FM-200 CLEAN AGENT SYSTEM CONTROL
PANEL. MOUNT WITHIN 36" OF CONTROL
PANEL.
35 MONITOR MODULE FOR MONITORING OF
FM-200 CLEAN AGENT CONTROL PANEL.
MOUNT WITHIN 36" OF CONTROL PANEL.
36 CLEAN AGENT CONTROL PANEL "FM-200".
37 TYPICAL MONITOR MODULE FOR
SUPERVISION OF THE FIRE PUMP CIRCUIT
BREAKER DISCONNECTING MEANS. MOUNT
WITHIN 36" OF CIRCUIT BREAKER. A
SUPERVISORY SIGNAL SHALL BE SENT
WHENEVER THE CIRCUIT BREAKER IS
PLACED IN THE "OPEN" POSITION.
38 TYPICAL CIRCUIT BREAKER
DISCONNECTING MEANS SERVING THE FIRE
PUMP CONTROLLER/AUTOMATIC TRANSFER
SWITCH.
39 TYPICAL CONTROL MODULE FOR FAN COIL
UNIT SHUTDOWN. MOUNT WITHIN 36" OF
FAN COIL UNIT CONTROLLER.
40 TYPICAL FAN COIL UNIT CONTROLLER.
1 TYPICAL MOTOR STARTER SERVING HVAC
SYSTEM FAN.
2 CONTROL MODULE FOR FAN SHUT-DOWN.
LOCATE WITHIN 36" OF MOTOR STARTER OR
VARIABLE FREQUENCY DRIVE.
3 TYPICAL VARIABLE FREQUENCY DRIVE
SERVING HVAC SYSTEM FAN.
4 CONTROL MODULE SHALL RELEASE THE
HOLD-OPEN DOORS UPON ACTIVATION OF
THE FIRE ALARM SYSTEM. MODULE SHALL
BE LOCATED ABOVE FINISHED ACCESSIBLE
CEILING WITHIN 36" OF DOOR. WHERE
CEILING SPACE IS NOT ACCESSIBLE THE
MODULE SHALL BE FLUSH MOUNTED IN THE
CEILING WITHIN 36" OF DOOR.
5 TYPICAL 24V DOOR HOLD-OPEN DEVICE
SUPPLIED WITH DOOR HARDWARE.
POWERED FROM THE FIRE ALARM SYSTEM.
6 CONNECT TO ADDITIONAL DEVICES, SEE
FIRE ALARM FLOOR PLANS FOR QUANTITY.
7 LOCATE MONITOR MODULE WITHIN 36" OF
THE FLOW OR TAMPER SWITCH WHICH IT
SERVES.
8 TYPICAL ELEVATOR CONTROLLER.
9 PROVIDE THREE CONTROL MODULES FOR
EACH ELEVATOR CONTROLLER FOR THE
FOLLOWING FUNCTIONS: MOUNT WITHIN 36"
OF ELEVATOR CONTROLLER.
a. EL1 - MODULE SHALL ACTIVATE RECALL
TO THE DESIGNATED LEVEL FOR
ACTUATION OF ELEVATOR LOBBY SMOKE
DETECTORS OTHER THAN THE DESIGNATED
LEVEL LOBBY.
b. EL2 - MODULE SHALL ACTIVATE RECALL
TO THE ALTERNATE LEVEL FROM
ACTUATION OF ELEVATOR LOBBY SMOKE
DETECTORS AT THE DESIGNATED LEVEL
LOBBY.
c. EL3 - MODULE SHALL ACTIVATE THE
FIREFIGHTERS HELMET SIGNAL WHEN
RECALL IS INITIATED BY THE SMOKE
DETECTOR IN THE ELEVATOR MACHINE
ROOM OR HOISTWAY.
10 CONTROL MODULE FOR ACTIVATION OF THE
POCKET MOUNTED FIRE DOOR. CONTROL
MODULE SHALL TRIGGER THE DOOR TO
AUTOMATICALLY CLOSE UPON ACTIVATION
OF THE BUILDING'S FIRE ALARM SYSTEM.
MOUNT THE CONTROL MODULE WITHIN 36"
OF THE FIRE DOOR CONTROL PANEL.
11 CONTROL MODULE FOR ACTIVATION OF
ELEVATOR SHUNT TRIP DEVICE. MOUNT
WITHIN 36" OF ELEVATOR SWITCH. SEE
1/FA602 FOR CONNECTION DIAGRAM.
12 TYPICAL POCKET FIRE DOOR CONTROLLER.
13 ELEVATOR CONTROL SWITCH. SEE 1/FA602
FOR CONNECTION DIAGRAM.
14 TYPICAL AUTOMATIC DOOR OPERATOR
LOCATED IN CORRIDOR RATED WALL.
15 CONTROL MODULE SHALL DEACTIVATE THE
AUTOMATIC DOOR UPON ACTIVATION OF
THE FIRE ALARM SYSTEM. MODULE SHALL
BE LOCATED ABOVE FINISHED ACCESSIBLE
CEILING WITHIN 36" OF DOOR CONTROLLER.
WHERE CEILING SPACE IS NOT ACCESSIBLE,
THE MODULE SHALL BE FLUSH MOUNTED IN
THE CEILING WITHIN 36" OF THE DOOR
CONTROLLER.
16 MONITOR MODULE FOR MONITORING OF
THE ELEVATOR SHUNT TRIP POWER
CIRCUIT. MOUNT WITHIN 36" OF ELEVATOR
SWITCH. SEE 1/FA602 FOR CONNECTION
DIAGRAM.
17 TYPICAL FIRE ALARM POWER
SUPPLY/AMPLIFIER CABINET SERVING
NOTIFICATION DEVICES. SEE SHEET
1/FA601 AND 1/FA603 FOR ADDITIONAL
CONNECTIONS AND REQUIREMENTS.
18 SIGNALING LINE CIRCUIT (SLC) BACKBONE
NTS2 TYPICAL FIRE ALARM DEVICE CONNECTION DIAGRAM
NOT TO SCALE3 KITCHEN EQUIPMENT SHUNT TRIP WIRING DIAGRAMS
SY
M
D E S
C R
IP
TI
O N
D
DAA FCPS
C C
I
I
120V LIFE SAFETY CIRCUIT, SEE SHEET
FA601
CONTROL MODULE
FOR ACTIVATION
OF STROBES
INCOMING SIGNALING LINE CIRCUIT
(SLC) BACKBONE FROM FACP/FMCP
AUDIO CONTROL LOOP
TO ADDITIONAL FAPS
CLASS A BACKBONE WIRING
DIGITAL AUDIO AMPLIFIER
WITH BATTERY BACKUP
TYPICAL ISOLATION MODULE
TYPICAL REMOTE FIRE
ALARM CONTROL UNIT
AUDIO CONTROL LOOP
TO ADDITIONAL FAPS
OUTGOING SIGNALING LINE CIRCUIT
(SLC) BACKBONE TO FACP/FMCP
CLASS A BACKBONE
WIRING
POWER SUPPLIES WITH
BATTERY BACKUP
TYPICAL CLASS A SPEAKER
CIRCUIT SERVING SMOKE ZONE.
TYPICAL CLASS A STROBE
CIRCUIT SERVING SMOKE ZONE.
TYPICAL NOTIFICATION APPLIANCE CIRCUIT,
SEE SHEET FA601 FOR QUANTITY OF CIRCUITS.
TYPICAL CLASS A SIGNALING LINE
CIRCUIT AND POWER CIRCUIT SERVING
SMOKE ZONE DEVICES, SEE SHEET
FA601 FOR QUANTITY OF CIRCUITS.
CONTROL MODULE
FOR ACTIVATION
OF SPEAKERS
NOTES:
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
NT
S
FA603
TY
PI
CA
L F
IR
E
AL
AR
M
CO
NN
EC
TI
ON
D
IA
GR
AM
RL
W
RL
W
KL
M
FA
NTS1 FIRE ALARM REMOTE POWER SUPPLY/AMPLIFIER CABINET (FAPS) CONNECTION DIAGRAM
NTS2 FIRE ALARM TRANSMITTER ANTENNA MOUNTING DETAIL
1 FIRE ALARM SYSTEM ANTENNA.
2 TWO HOLE CONDUIT STRAP.
3 LIGHTNING ARRESTOR MOUNTED ON
ANTENNA MAST.
4 ANTENNA CABLE.
5 TYPICAL WEATHER HEAD.
6 1 5/8" SQUARE CHANNEL STEEL.
MECHANICALLY SECURE TO ANTENNA
MOUNTING RACK AS REQUIRED.
7 ANTENNA CABLE DOWN TO FIRE ALARM
RADIO TRANSMITTER PANEL IN ROOM 2134.
SEE H-FA121 FOR LOCATION. ROUTE
ANTENNA CABLE IN 1" CONDUIT FROM
ROOM 4102 TO FIRE ALARM RADIO
TRANSMITTER.
8 PROVIDE #6 AWG INSULATED COPPER
GROUND CONDUCTOR. BOND TO NEAREST
COMMUNICATIONS GROUND BUS (TGB).
9 ANTENNA MAST.
10 SEE H-AE547 FOR RACK DETAIL.
11 TYPICAL CONDUIT TO COMMUNICATIONS
ROOM 4102. SEE SHEET H-ET141 FOR
ADDITIONAL INFORMATION.
SY
M
D E S
C R
IP
TI
O N
D
FIRE ALARM SYSTEM
SEQUENCE OF OPERATION MATRIX
SYSTEM INPUTS
SY
ST
EM
O
UT
PU
TS
ACTIVATE FIRE ALARM NOTIFICATION APPLIANCE
STROBE LIGHTS AND SPEAKERS (SEE NOTE B AND
E)
MA
NU
AL
P
UL
L S
TA
TI
ON
W
AT
ER
F
LO
W
S W
IT
CH
SP
RI
NK
LE
R
VA
LV
E
TA
MP
ER
S
W
IT
CH
W
AT
ER
F
LO
W
S W
IT
CH
EL
EV
AT
OR
MA
CH
IN
E
RO
OM
CO
MP
UT
ER
R
OO
M
DU
CT
M
OU
NT
ED
SM
OK
E
DE
TE
CT
OR
GR
OU
ND
F
AU
LT
CO
ND
UC
TO
R
BR
EA
K
DISPLAY ALARM INDICATION AT FACP AND FAAP
TRANSMIT ALARM SIGNAL TO THE FIRE
DEPARTMENT
RECORD INFORMATION ON CPU
EL
EV
AT
OR
M
AC
HI
NE
R
OO
M
SM
OK
E
DE
TE
CT
OR
EL
EV
AT
OR
LO
BB
Y
SM
OK
E
DE
TE
CT
OR
PR
IM
AR
Y
LE
VE
L
EL
EV
AT
OR
LO
BB
Y
SM
OK
E
DE
TE
CT
OR
AL
TE
RN
AT
E
LE
VE
L
AR
EA
S
MO
KE
D
ET
EC
TO
RS
SM
OK
E
DE
TE
CT
OR
A
T
HE
LD
O
PE
N
SM
OK
E
DO
OR
O
R
FI
RE
S
HU
TT
ER
DU
CT
M
OU
NT
ED
S
MO
KE
D
ET
EC
TO
R
AC
TI
VA
TI
ON
O
F
LO
CA
L O
PE
RA
TO
RS
CO
NS
OL
E
PR
E-
RE
CO
RD
ED
M
ES
SA
GE
(L
OC
MA
SS
N
OT
IF
IC
AT
IO
N
LIV
E
VO
IC
E
ME
SS
AG
E
(L
OC
EL
EV
AT
OR
S
HU
NT
T
RI
P
CO
IL
LO
SS
O F
PO
W
ER
PO
ST
IN
DI
CA
TI
NG
V
AL
VE
KI
TC
HE
N
HO
OD
S
UP
PE
SI
ON
S
YS
TE
M
DISPLAY SUPERVISION CONDITION AT FACP AND
FAAP
TRANSMIT SUPERVISORY SIGNAL TO THE FIRE
DEPARTMENT
DISPLAY TROUBLE CONDITION AT FACP AND FAAP
TRANSMIT TROUBLE SIGNAL TO BASE FIRE
DEPARTMENT
DE-ENERGIZE HELD OPEN DOORS IN ASSOCIATED
SMOKE ZONE
INITIATE ELEVATOR RECALL, PRIMARY LEVEL
INITIATE ELEVATOR RECALL, ALTERNATE LEVEL
ACTIVATE MASS NOTIFICATION STROBES
OVERRIDE PRE-RECORDED DIGITIZED VOICE
MESSAGE
SHUT DOWN AIR HANDLING UNITS AND EXHAUST
FANS ON FLOOR IN ALARM
DISCONNECT POWER TO ASSOCIATED ELEVATOR
SHUT DOWN KITCHEN HOOD AIR SUPPLY FAN
OVERRIDE THE LOCAL OPERATING CONSOLE
ACTIVATE CLOSURE OF FIRE PARTITION
SHUT DOWN COMPUTER ROOM POWER PANEL 19
FI
RE
A
LA
RM
S
YS
TE
M
LIV
E
VO
IC
E
ME
SS
AG
E
AC
TI
VA
TI
ON
O
F
MA
SS
N
OT
IF
IC
AT
IO
N
SY
ST
EM
A
UT
ON
OM
OU
S
CO
NT
RO
L
UN
IT
P
RE
-R
EC
OR
DE
D
ME
SS
AG
E
AC
TI
VA
TI
ON
O
F
AR
EA
O
F
RE
FU
GE
TE
LE
PH
ON
E
ST
AT
IO
N
SM
OK
E
DE
TE
CT
OR
A
T
FI
RE
P
AR
TI
TI
ON
FI
RE
P
UM
P
RU
NN
IN
G
FI
RE
P
UM
P
LO
SS
O
F
PH
AS
E
FI
RE
P
UM
P
PH
AS
E
RE
VE
RS
AL
AC
TI
VA
TI
ON
O
F
MA
SS
N
OT
IF
IC
AT
IO
N
SY
ST
EM
A
UT
ON
OM
OU
S
CO
NT
RO
L
UN
IT
LI
VE
V
OI
CE
M
ES
SA
GE
FI
RE
P
UM
P
CO
NE
CT
ED
T
O
AL
TE
RN
AT
E
SO
UR
CE
A B C D E F G H I J K L M N O P Q R S T U V W X Y AA BB
AC
TI
VA
TI
ON
O
F
TH
E
CO
MP
UT
ER
RO
OM
C
LE
AN
A
GE
NT
S
YS
TE
M
DD
CO
MP
UT
ER
R
OO
M
CL
EA
N
AG
EN
T
SY
ST
EM
C
OM
MO
N
TR
OU
BL
E
CC EE
FI
RE
P
UM
P
DI
SC
ON
NE
CT
O
PE
N
SHEET NOTES:
NOTES:
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1 :
FA604
FI
RE
A
LA
RM
M
AS
S
NO
TI
FI
CA
TI
ON
S
EQ
UE
NC
E
OF
O
PE
RA
TI
ON
RL
W
RL
W
KL
M
FA
A. THE HVAC SYSTEMS THE SURGERY AREA SHALL
BE SHUT DOWN ONLY BY SUPPLY DUCT
MOUNTED
SMOKE DETECTORS SERVING THE SURGERY
AREA.
B. CLINIC: THE CLINIC PORTION OF THE FACILITY
SHALL USE A GENERAL ALARM EVACUATION
SCHEME. UPON ACTIVATION OF THE SYSTEM
INPUTS AS INDICATED ON THIS MATRIX, ALL OF
THE FIRE ALARM NOTIFICATION APPLIANCE
STROBES AND SPEAKERS SHALL BE ACTIVATED
THROUGHOUT THE ENTIRE CLINIC. THE VOICE
ALARM MESSAGE IN THE CLINIC SHALL EVACUATE
THE ENTIRE CLINIC. A CODED AUDIO MESSAGE
SHALL BE DISTRIBUTED TO THE FIRE ALARM
SPEAKERS IN THE HOSPITAL AND CUP, THE
STROBES LOCATED OUTSIDE OF THE CLINIC
SMOKE ZONES SHALL NOT BE ACTIVATED. THE
CODED MESSAGE SHALL BE AS DIRECTED BY THE
CONTRACTING OFFICER AND POST FIRE CHIEF.
HOSPITAL: THE HOSPITAL PORTION OF THE
FACILITY SHALL USE A "DEFEND IN PLACE" TYPE
PARTIAL EVACUATION SCHEME FOR THE HOSPITAL
OCCUPANCY ONLY. UPON ACTIVATION OF THE
SYSTEM INPUTS AS INDICATED ON THIS MATRIX,
ONLY THE FIRE ALARM NOTIFICATION APPLIANCE
STROBES AND SPEAKERS LOCATED WITHIN THE
SMOKE ZONE UNDER ALARM SHALL BE
ACTIVATED. A CODED AUDIO MESSAGE SHALL BE
DISTRIBUTED TO THE FIRE ALARM SPEAKERS IN
ALL OTHER SMOKE ZONES IN THE HOSPITAL,
CLINIC AND CUP, THE STROBES LOCATED
OUTSIDE OF THE SMOKE ZONE UNDER ALARM
SHALL NOT BE ACTIVATED. THE CODED MESSAGE
SHALL BE AS DIRECTED BY THE CONTRACTING
OFFICER AND POST FIRE CHIEF.
CUP: THE CUP PORTION OF THE FACILITY
SHALL USE A GENERAL ALARM EVACUATION
SCHEME. UPON ACTIVATION OF THE SYSTEM
INPUTS AS INDICATED ON THIS MATRIX, ALL OF
THE FIRE ALARM NOTIFICATION APPLIANCE
STROBES AND SPEAKERS SHALL BE ACTIVATED
THROUGHOUT THE ENTIRE CUP. THE VOICE
ALARM MESSAGE IN THE CUP SHALL EVACUATE
THE ENTIRE CUP. A CODED AUDIO MESSAGE
SHALL BE DISTRIBUTED TO THE FIRE ALARM
SPEAKERS IN THE HOSPITAL AND CLINIC, THE
STROBES LOCATED OUTSIDE OF THE CUP
SHALL NOT BE ACTIVATED. THE CODED MESSAGE
SHALL BE AS DIRECTED BY THECONTRACTING
OFFICER AND POST FIRE CHIEF.
C. REFER TO SHEET FA602 FOR ADDITIONAL
REQUIREMENTS.
D. ALARMS WITHIN THE CLINIC SHALL NOT ACTIVE
NOTIFICATION APPLIANCE STROBES/SPEAKERS
OR SHUT DOWN HVAC FANS IN THE HOSPITAL.
ALARMS WITHIN THE HOSPITAL SHALL NOT ACTIVE
NOTIFICATION APPLIANCE STROBES/SPEAKERS
OR SHUT DOWN HVAC FANS IN THE CLINIC.
E. THE SPEAKERS LOCATED IN THE STAIRWELLS
AND THE ELEVATOR CABS SHALL ONLY BE
ACTIVATED BY USING THE LIVE ANNOUNCEMENT
MICROPHONES. THESE SPEAKERS SHALL NOT BE
ACTIVATED AUTOMATICALLY.
SY
M
D E S
C R
IP
TI
O N
D
FIRE ALARM SYSTEM
SEQUENCE OF OPERATION MATRIX
SYSTEM INPUTS
SY
ST
EM
O
UT
PU
TS
MA
NU
AL
P
UL
L S
TA
TI
ON
W
AT
ER
F
LO
W
S W
IT
CH
SP
RI
NK
LE
R
VA
LV
E
TA
MP
ER
S
W
IT
CH
W
AT
ER
F
LO
W
S W
IT
CH
EL
EV
AT
OR
MA
CH
IN
E
RO
OM
CO
MP
UT
ER
R
OO
M
DU
CT
M
OU
NT
ED
SM
OK
E
DE
TE
CT
OR
GR
OU
ND
F
AU
LT
CO
ND
UC
TO
R
BR
EA
K
EL
EV
AT
OR
M
AC
HI
NE
R
OO
M
SM
OK
E
DE
TE
CT
OR
EL
EV
AT
OR
LO
BB
Y
SM
OK
E
DE
TE
CT
OR
PR
IM
AR
Y
LE
VE
L
EL
EV
AT
OR
LO
BB
Y
SM
OK
E
DE
TE
CT
OR
AL
TE
RN
AT
E
LE
VE
L
AR
EA
S
MO
KE
D
ET
EC
TO
RS
SM
OK
E
DE
TE
CT
OR
A
T
HE
LD
O
PE
N
SM
OK
E
DO
OR
O
R
FI
RE
S
HU
TT
ER
DU
CT
M
OU
NT
ED
S
MO
KE
D
ET
EC
TO
R
AC
TI
VA
TI
ON
O
F
LO
CA
L O
PE
RA
TO
RS
CO
NS
OL
E
PR
E-
RE
CO
RD
ED
M
ES
SA
GE
(L
OC
MA
SS
N
OT
IF
IC
AT
IO
N
LIV
E
VO
IC
E
ME
SS
AG
E
(L
OC
EL
EV
AT
OR
S
HU
NT
T
RI
P
CO
IL
LO
SS
O F
PO
W
ER
PO
ST
IN
DI
CA
TI
NG
V
AL
VE
KI
TC
HE
N
HO
OD
S
UP
PE
SI
ON
S
YS
TE
M
DISCONNECT POWER AND FUEL SOURCE FROM
KITCHEN COOKING EQUIPMENT
MUTE PUBLIC ADDRESS SYSTEM SPEAKERS
SHUT-OFF POWER TO AUTOMATIC MOTORIZED
DOORS IN EGRESS PATH OF ASSOCIATED SMOKE
ZONE IN ALARM
ACTIVATE SELECTED MASS NOTIFICATION
PRE-RECORDED MESSAGE
TEMPORARILY OVERRIDE FIRE ALARM AUDIBLE
AND VISUAL SIGNALS AND DISPLAY A DISTINCT
SUPERVISORY SIGNAL AT THE FACP
ACTIVATE LIVE MASS NOTIFICATION VOICE
ANNOUNCEMENT
SHUT DOWN COMPUTER ROOM AIR
CONDITIONING UNIT 20
FI
RE
A
LA
RM
S
YS
TE
M
LIV
E
VO
IC
E
ME
SS
AG
E
AC
TI
VA
TI
ON
O
F
MA
SS
N
OT
IF
IC
AT
IO
N
SY
ST
EM
A
UT
ON
OM
OU
S
CO
NT
RO
L
UN
IT
P
RE
-R
EC
OR
DE
D
ME
SS
AG
E
CO
MP
UT
ER
R
OO
M
CL
EA
N
AG
EN
T
SY
ST
EM
C
OM
MO
N
TR
OU
BL
E
SM
OK
E
DE
TE
CT
OR
A
T
FI
RE
P
AR
TI
TI
ON
FI
RE
P
UM
P
RU
NN
IN
G
FI
RE
P
UM
P
LO
SS
O
F
PH
AS
E
FI
RE
P
UM
P
PH
AS
E
RE
VE
RS
AL
AC
TI
VA
TI
ON
O
F
MA
SS
N
OT
IF
IC
AT
IO
N
SY
ST
EM
A
UT
ON
OM
OU
S
CO
NT
RO
L
UN
IT
LI
VE
V
OI
CE
M
ES
SA
GE
FI
RE
P
UM
P
CO
NE
CT
ED
T
O
AL
TE
RN
AT
E
SO
UR
CE
A B C D E F G H I J K L M N O P Q R S T U V W X Y AA BB
ACTIVATE FIRE FIGHTERS SERVICE VISUAL
SIGNAL INTERMITTENTLY
ACTIVATE FIRE FIGHTERS SERVICE VISUAL
SIGNAL STEADY
CLOSE SMOKE/FIRE DAMPERS IN ASSOCIATED
SMOKE ZONE
CLOSE FIRE/SMOKE DAMPERS SERVING
COMPUTER ROOM
AC
TI
VA
TI
ON
O
F
TH
E
CO
MP
UT
ER
RO
OM
C
LE
AN
A
GE
NT
S
YS
TE
M
CC
31ACTIVATE AREA OF REFUGE BASE STATION IN
FACP/FMCP
AC
TI
VA
TI
ON
O
F
AR
EA
O
F
RE
FU
GE
TE
LE
PH
ON
E
ST
AT
IO
N
DD
SHEET NOTES:
NOTES:
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
1 :
FA605
FI
RE
A
LA
RM
M
AS
S
NO
TI
FI
CA
TI
ON
S
EQ
UE
NC
E
OF
O
PE
RA
TI
ON
RL
W
RL
W
KL
M
FA
SY
M
D E S
C R
IP
TI
O N
D
AT
E
A. THE HVAC SYSTEMS THE SURGERY AREA SHALL
BE SHUT DOWN ONLY BY SUPPLY DUCT
MOUNTED
SMOKE DETECTORS SERVING THE SURGERY
AREA.
B. CLINIC: THE CLINIC PORTION OF THE FACILITY
SHALL USE A GENERAL ALARM EVACUATION
SCHEME. UPON ACTIVATION OF THE SYSTEM
INPUTS AS INDICATED ON THIS MATRIX, ALL OF
THE FIRE ALARM NOTIFICATION APPLIANCE
STROBES AND SPEAKERS SHALL BE ACTIVATED
THROUGHOUT THE ENTIRE CLINIC. THE VOICE
ALARM MESSAGE IN THE CLINIC SHALL EVACUATE
THE ENTIRE CLINIC. A CODED AUDIO MESSAGE
SHALL BE DISTRIBUTED TO THE FIRE ALARM
SPEAKERS IN THE HOSPITAL AND CUP, THE
STROBES LOCATED OUTSIDE OF THE CLINIC
SMOKE ZONES SHALL NOT BE ACTIVATED. THE
CODED MESSAGE SHALL BE AS DIRECTED BY THE
CONTRACTING OFFICER AND POST FIRE CHIEF.
HOSPITAL: THE HOSPITAL PORTION OF THE
FACILITY SHALL USE A "DEFEND IN PLACE" TYPE
PARTIAL EVACUATION SCHEME FOR THE HOSPITAL
OCCUPANCY ONLY. UPON ACTIVATION OF THE
SYSTEM INPUTS AS INDICATED ON THIS MATRIX,
ONLY THE FIRE ALARM NOTIFICATION APPLIANCE
STROBES AND SPEAKERS LOCATED WITHIN THE
SMOKE ZONE UNDER ALARM SHALL BE
ACTIVATED. A CODED AUDIO MESSAGE SHALL BE
DISTRIBUTED TO THE FIRE ALARM SPEAKERS IN
ALL OTHER SMOKE ZONES IN THE HOSPITAL,
CLINIC AND CUP, THE STROBES LOCATED
OUTSIDE OF THE SMOKE ZONE UNDER ALARM
SHALL NOT BE ACTIVATED. THE CODED MESSAGE
SHALL BE AS DIRECTED BY THE CONTRACTING
OFFICER AND POST FIRE CHIEF.
CUP: THE CUP PORTION OF THE FACILITY
SHALL USE A GENERAL ALARM EVACUATION
SCHEME. UPON ACTIVATION OF THE SYSTEM
INPUTS AS INDICATED ON THIS MATRIX, ALL OF
THE FIRE ALARM NOTIFICATION APPLIANCE
STROBES AND SPEAKERS SHALL BE ACTIVATED
THROUGHOUT THE ENTIRE CUP. THE VOICE
ALARM MESSAGE IN THE CUP SHALL EVACUATE
THE ENTIRE CUP. A CODED AUDIO MESSAGE
SHALL BE DISTRIBUTED TO THE FIRE ALARM
SPEAKERS IN THE HOSPITAL AND CLINIC, THE
STROBES LOCATED OUTSIDE OF THE CUP
SHALL NOT BE ACTIVATED. THE CODED MESSAGE
SHALL BE AS DIRECTED BY THECONTRACTING
OFFICER AND POST FIRE CHIEF.
C. REFER TO SHEET FA602 FOR ADDITIONAL
REQUIREMENTS.
D. ALARMS WITHIN THE CLINIC SHALL NOT ACTIVE
NOTIFICATION APPLIANCE STROBES/SPEAKERS
OR SHUT DOWN HVAC FANS IN THE HOSPITAL.
ALARMS WITHIN THE HOSPITAL SHALL NOT ACTIVE
NOTIFICATION APPLIANCE STROBES/SPEAKERS
OR SHUT DOWN HVAC FANS IN THE CLINIC.
E. THE SPEAKERS LOCATED IN THE STAIRWELLS
AND THE ELEVATOR CABS SHALL ONLY BE
ACTIVATED BY USING THE LIVE ANNOUNCEMENT
MICROPHONES. THESE SPEAKERS SHALL NOT BE
ACTIVATED AUTOMATICALLY.
B
B
B
B
B
B
B
B B B B B B B B B B B
B B B B B B B B B B B
B B B B
A A
A A
A A
A
A A A A A A A
A A A A A A A
A
A
A
A
A
A
AA AAA A A A A
A
A
A
A
A
A
B B
B B
DN
DN
DN1
DN1
DN1
DN2
DN2
GL
GL
GL GL
GL
GL
GL
GL
1 2
3 4 5.6
5.9
7 8 9 10
A.3
Z
B
C
D
E.1
E.3
E.9
F.4
GL
20'-0" MAXIMUM. TYPICAL
FOR ALL PERIMETER STRIKE
TERMINATION DEVICES
B
B
B
B
B
B
B
B
B B
B B B B
B
B
B
B
B
B
B
B B B B
B B
B
B
B
GL
GL
GL
GL
GL
GL GL
DN5
DN5
GL
GL
GL
GL
DN
2 2
GLDN5
DN5
DN1
DN2
DN1
DN2
DN1
ELEVATION: 67'-2"
ELEVATION: 48'-0"
ELEVATION: 35'-0"
DN
DN1
DN5
DN1
DN1
3 4
DN1
A. PROVIDE BONDING CONNECTION TO ALL ROOF
DRAINS AND VENT PIPES.
B. USE EXOTHERMIC WELD CONNECTIONS FOR
ALL CONNECTIONS BELOW GRADE.
C. ALL LIGHTNING PROTECTION COMPONENTS
SHALL BE CLASS I, UNLESS OTHERWISE NOTED.
D. PROVIDE BONDING CONNECTION TO ALL METAL
BODIES LOCATED ON ROOF, INCLUDING
METALLIC LADDERS.
E. REFER TO SPECIFICATIONS SECTION
264101.0010 FOR ADDITIONAL REQUIREMENTS.
SHEET NOTES:
NOTES:
N
50'0 10' 30'
1/16"=1'-0" GRAPHIC SCALE
10'
KEY PLAN
A
B
P
HOSPITALCLINIC
H
V
KEY NOTES 00
Sheet Reference Number
AP
PR
C O
R
PS
O F
EN
G
IN
EE
R S
D
EP
AR
TM
EN
T
O F
TH
E
AR
M
Y
SA
C
R
AM
EN
TO
, C
AL
IF
O
R N
IA
FO
R
T
IR
W
IN
C
AL
IF
O
R N
IA
D es ig ne d by
D ra w n by
D es ig n fil e no
D at e:
R ev ie w ed b y:
S ub m itt ed b y:
Fi le n am e:
S pe c N o:
D ra w in g C od e:
P lo t d at e:
D w g sc al e:
R ev
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
FO
R
T
IR
W
IN
H O
S P
IT
AL
R
EP
L A
C
EM
EN
T
4 3 2 1
C
B
A
SHEET OF 1985
Sacramento District
8-
- 0
D
EC
EM
BE
R, RO
N
W . L
OW
RY
I52 1-
As in dic ate d
H-EQ15A
LIG
HT
NI
NG
P
RO
TE
CT
IO
N
PL
AN
HO
SP
IT
AL
Au tho r
De sig ne r
Ch ec ke r
H-
EQ
A
1 REFER TO SHEET H-EQ15B FOR CONTINUATION.
2 TO AMBULANCE SHELTER. REFER TO 3/EQ401
FOR CONTINUATION.
3 ROUTE DOWN CONDUCTOR DOWN TO GRADE,
IN 1" PVC CONDUIT, CONCEALED INSIDE STEEL
TUBE SUPPORT.
4 MOUNT AIR TERMINAL TO TOP OF TRELLIS
BEAM. SECURE TERMINAL BASE IN PLACE WITH
AN APPLICATION OF ADHESIVE COMPOUND
THAT IS COMPATIBLE WITH TRELLIS.
SY
M
D E S
C R
IP
TI
O N
D
| 600 VOLUME 6 COVER |
| 602 EG001-003 |
| EG001 - ELECTRICAL SYMBOLS LEGEND AND ABBREVIATIONS |
| EG002 - ELECTRICAL SYMBOLS LEGEND |
| EG003 - ELECTRICAL SYMBOLS LEGEND |
| 604 EG004-006 |
| EG004 - TELECOMMUNICATIONS SYMBOL LEGEND |
| EG005 - TELECOMMUNICATIONS SYMBOL LEGEND |
| EG006 - FIRE ALARM SYMBOL LEGEND |
| 606 ES100 |
| 608 ED100s |
| ED101 - ELECTRICAL SITE UTILITY KEY PLAN - DEMOLITION |
| ED102 - ELECTRICAL SITE UTILITY KEY PLAN - DEMOLITION |
| 610 ES101-120 |
| ES100 - ELECTRICAL SITE UTILITY KEY PLAN |
| ES101 - ELECTRICAL SITE UTILITY PLAN |
| ES102 - ELECTRICAL SITE UTILITY PLAN |
| ES103 - ELECTRICAL SITE UTILITY PLAN |
| ES104 - ELECTRICAL SITE UTILITY PLAN |
| ES105 - ELECTRICAL SITE UTILITY PLAN |
| ES106 - ELECTRICAL SITE UTILITY PLAN |
| ES107 - ELECTRICAL SITE UTILITY PLAN |
| ES108 - ELECTRICAL SITE UTILITY PLAN |
| ES109 - ELECTRICAL SITE UTILITY PLAN |
| ES110 - ELECTRICAL SITE UTILITY PLAN |
| ES111 - ELECTRICAL SITE UTILITY PLAN |
| ES112 - ELECTRICAL SITE UTILITY PLAN |
| ES113 - ELECTRICAL SITE UTILITY PLAN |
| ES114 - ELECTRICAL SITE UTILITY PLAN |
| ES115 - ELECTRICAL SITE UTILITY PLAN |
| ES116 - ELECTRICAL SITE UTILITY PLAN |
| ES117 - ELECTRICAL SITE UTILITY PLAN |
| ES118 - ELECTRICAL SITE UTILITY PLAN |
| ES119 - ELECTRICAL SITE UTILITY PLAN |
| ES120 - ELECTRICAL SITE UTILITY PLAN |
| 612 ES121-138 |
| ES121 - ELECTRICAL SITE UTILITY PLAN |
| ES122 - ELECTRICAL SITE UTILITY PLAN |
| ES123 - ELECTRICAL SITE UTILITY PLAN |
| ES124 - ELECTRICAL SITE UTILITY PLAN |
| ES125 - ELECTRICAL SITE UTILITY PLAN |
| ES126 - ELECTRICAL SITE UTILITY PLAN |
| ES127 - ELECTRICAL SITE UTILITY PLAN |
| ES128 - ELECTRICAL SITE UTILITY PLAN |
| ES129 - ELECTRICAL SITE UTILITY PLAN |
| ES130 - ELECTRICAL SITE UTILITY PLAN |
| ES131 - ELECTRICAL SITE UTILITY PLAN |
| ES132 - ELECTRICAL SITE UTILITY PLAN |
| ES133 - ELECTRICAL SITE UTILITY PLAN |
| ES134 - ELECTRICAL SITE UTILITY PLAN |
| ES135 - ELECTRICAL SITE UTILITY PLAN |
| ES136 - ELECTRICAL SITE UTILITY PLAN |
| ES137 - ELECTRICAL SITE UTILITY PLAN |
| ES138 - ELECTRICAL SITE UTILITY PLAN |
| 614 ES200s |
| ES201 - OVERALL SOLAR ARRAY KEYPLAN |
| ES202 - SOLAR ARRAY PLAN |
| ES203 - SOLAR ARRAY PLAN |
| 616 ES300s |
| ES300 - SITE LIGHTING KEY PLAN |
| ES301 - SITE LIGHTING |
| ES302 - SITE LIGHTING |
| ES303 - SITE LIGHTING |
| ES304 - SITE LIGHTING |
| ES305 - SITE LIGHTING |
| ES306 - SITE LIGHTING |
| ES307 - SITE LIGHTING |
| ES308 - SITE LIGHTING |
| ES309 - SITE LIGHTING |
| ES310 - SITE LIGHTING |
| ES311 - SITE LIGHTING |
| ES312 - SITE LIGHTING |
| 618 ES400s |
| ES401 - ENLARGED ADN BUILDING PLAN |
| ES404 - ENLARGED PREPACKAGED INVERTER BUILDINGS |
| ES405 - ENLARGED PLANS |
| ES406 - ENLARGED PLANS |
| ES407 - ENLARGED PLANS |
| 620 ES500s |
| ES501 - SITE DETAILS |
| ES502 - SITE DETAILS |
| ES503 - SITE DETAILS |
| ES504 - SITE DETAILS |
| ES505 - SITE DETAILS |
| ES506 - SITE DETAILS |
| ES507 - SITE DETAILS |
| ES508 - SITE DETAILS |
| ES509 - SITE DETAILS |
| ES510 - SITE DETAILS |
| ES511 - SITE DETAILS |
| ES512 - SITE DETAILS |
| 622 ES800s |
| ES801 - SITE UTILITY SCHEDULES |
| ES802 - SITE UTILITY SCHEDULES |
| ES803 - SITE UTILITY SCHEDULES |
| ES804 - SITE UTILITY SCHEDULES |
| ES805 - SITE UTILITY SCHEDULES |
| ES806 - SITE UTILITY SCHEDULES |
| 624 H-EL100s-400s |
| H-EL111 - LEVEL 1, ZONE 1, FLOOR PLAN - LIGHTING |
| H-EL112 - LEVEL 1, ZONE 2, FLOOR PLAN - LIGHTING |
| H-EL113 - LEVEL 1, ZONE 3, FLOOR PLAN - LIGHTING |
| H-EL114 - LEVEL 1, ZONE 4, FLOOR PLAN - LIGHTING |
| H-EL115 - LEVEL 1, ZONE 5, FLOOR PLAN – LIGHTING |
| H-EL121 - LEVEL 2, ZONE 1, FLOOR PLAN - LIGHTING |
| H-EL122 - LEVEL 2, ZONE 2, FLOOR PLAN - LIGHTING |
| H-EL123 - LEVEL 2, ZONE 3, FLOOR PLAN - LIGHTING |
| H-EL124 - LEVEL 2, ZONE 4, FLOOR PLAN - LIGHTING |
| H-EL125 - LEVEL 2, ZONE 5, FLOOR PLAN – LIGHTING |
| H-EL131 - LEVEL 3, ZONE 1, FLOOR PLAN - LIGHTING |
| H-EL132 - LEVEL 3, ZONE 2, FLOOR PLAN - LIGHTING |
| H-EL133 - LEVEL 3, ZONE 3, FLOOR PLAN - LIGHTING |
| H-EL134 - LEVEL 3, ZONE 4, FLOOR PLAN - LIGHTING |
| H-EL135 - LEVEL 3, ZONE 5, FLOOR PLAN – LIGHTING |
| H-EL141 - LEVEL 4, ZONE 1, FLOOR PLAN - LIGHTING |
| H-EL142 - LEVEL 4, ZONE 2, FLOOR PLAN - LIGHTING |
| H-EL144 - LEVEL 4, ZONE 4, FLOOR PLAN - LIGHTING |
| H-EL301 - LIGHTING SECTION PLANS |
| H-EL302 - LIGHTING SECTION PLANS |
| H-EL303 - LIGHTING SECTION PLANS |
| H-EL401 - LIGHTING ENLARGED PLANS |
| H-EL402 - LIGHTING ENLARGED PLANS |
| H-EL403 - LIGHTING ENLARGED PLANS |
| H-EL404 - LIGHTING ENLARGED PLANS |
| 626 EL500s-800s |
| EL501 - LIGHTING FIXTURE DETAILS |
| EL502 - LIGHTING FIXTURE DETAILS |
| EL503 - LIGHTING FIXTURE DETAILS |
| EL504 - LIGHTING FIXTURE DETAILS |
| EL505 - LIGHTING FIXTURE DETAILS |
| EL506 - LIGHTING FIXTURE DETAILS |
| EL507 - LIGHTING FIXTURE DETAILS |
| EL508 - LIGHTING FIXTURE DETAILS |
| EL509 - LIGHTING FIXTURE DETAILS |
| EL510 - LIGHTING FIXTURE DETAILS |
| EL511 - LIGHTING FIXTURE DETAILS |
| EL512 - LIGHTING FIXTURE DETAILS |
| EL601 - LIGHTING CONTROL DETAILS |
| EL602 - LIGHTING CONTROL DETAILS |
| EL603 - LIGHTING CONTROL DETAILS |
| EL604 - LIGHTING CONTROL DETAILS |
| EL605 - LIGHTING CONTROL DETAILS |
| EL606 - LIGHTING CONTROL DETAILS |
| EL607 - LIGHTING CONTROL DETAILS |
| EL701 - LIGHTING FIXTURE SCHEDULE |
| EL702 - LIGHTING FIXTURE SCHEDULE |
| EL703 - SITE LIGHTING FIXTURE SCHEDULE |
| EL801 - RELAY PANEL SCHEDULES |
| EL802 - RELAY PANEL SCHEDULES |
| 628 H-EP100s-400s |
| H-EP111 - LEVEL 1, ZONE 1, FLOOR PLAN - POWER |
| H-EP112 - LEVEL 1, ZONE 2, FLOOR PLAN - POWER |
| H-EP113 - LEVEL 1, ZONE 3, FLOOR PLAN - POWER |
| H-EP114 - LEVEL 1, ZONE 4, FLOOR PLAN - POWER |
| H-EP115 - LEVEL 1, ZONE 5, FLOOR PLAN - POWER |
| H-EP121 - LEVEL 2, ZONE 1, FLOOR PLAN - POWER |
| H-EP122 - LEVEL 2, ZONE 2, FLOOR PLAN - POWER |
| H-EP123 - LEVEL 2, ZONE 3, FLOOR PLAN - POWER |
| H-EP124 - LEVEL 2, ZONE 4, FLOOR PLAN - POWER |
| H-EP125 - LEVEL 2, ZONE 5, FLOOR PLAN - POWER |
| H-EP131 - LEVEL 3, ZONE 1, FLOOR PLAN - POWER |
| H-EP132 - LEVEL 3, ZONE 2, FLOOR PLAN - POWER |
| H-EP133 - LEVEL 3, ZONE 3, FLOOR PLAN - POWER |
| H-EP134 - LEVEL 3, ZONE 4, FLOOR PLAN - POWER |
| H-EP135 - LEVEL 3, ZONE 5, FLOOR PLAN - POWER |
| H-EP141 - LEVEL 4, ZONE 1, FLOOR PLAN - POWER |
| H-EP142 - LEVEL 4, ZONE 2, FLOOR PLAN - POWER |
| H-EP143 - LEVEL 4, ZONE 3, FLOOR PLAN - POWER |
| H-EP144 - LEVEL 4, ZONE 4, FLOOR PLAN - POWER |
| H-EP401 - ENLARGED FLOOR PLANS |
| H-EP402 - ENLARGED FLOOR PLANS |
| H-EP403 - ENLARGED FLOOR PLANS |
| H-EP404 - ENLARGED FLOOR PLANS |
| H-EP405 - ENLARGED FLOOR PLANS |
| H-EP406 - ENLARGED FLOOR PLANS |
| H-EP407 - ENLARGED FLOOR PLANS |
| H-EP408 - ENLARGED FLOOR PLANS |
| H-EP409 - ENLARGED ELEVATOR MACHINE ROOM POWER PLANS |
| H-EP410 - ENLARGED OPERATING ROOM POWER PLANS |
| H-EP411 - ENLARGED PLANS - SURGICAL EQUIPMENT LAYOUT |
| H-EP412 - ELEVATIONS AND CIRCUITING SCHEDULES - SURGICAL BOOMS |
| H-EP413 - ENLARGED LABORATORY POWER PLANS |
| H-EP414 - ENLARGED UPS AND DATA ROOM POWER PLANS |
| H-EP415 - ENLARGED NORTH KITCHEN-SERVERY SUITE POWER PLAN |
| H-EP416 - ENLARGED SOUTH KITCHEN-SERVERY SUITE POWER PLAN |
| H-EP417 - ENLARGED X-RAY ROOM POWER PLANS |
| H-EP418 - ENLARGED TYPICAL PATIENT ROOM POWER PLANS |
| H-EP419 - HEADWALL RECEPTACLE CIRCUITING SCHEDULES |
| H-EP420 - ENLARGED EYELANE ROOM POWER PLANS |
| H-EP421 - CT SCAN EQUIPMENT DRAWINGS |
| H-EP422 - CT SCAN EQUIPMENT DRAWINGS |
| H-EP423 - CT SCAN EQUIPMENT DRAWINGS |
| H-EP424 - CT SCAN EQUIPMENT DRAWINGS |
| 630 EP500s-800s |
| EP501 - ELECTRICAL DETAILS |
| EP502 - ELECTRICAL DETAILS |
| EP503 - ELECTRICAL DETAILS |
| EP504 - SWITCHGEAR ELEVATIONS - CUP |
| EP505 - SWITCHGEAR ELEVATIONS - HOSPITAL |
| EP506 - SWITCHBOARD ELEVATIONS - CLINIC |
| EP507 - ATS TERMINAL CABINET DETAILS |
| EP508 - AUTOMATIC TRANSFER SWITCH WIRING DIAGRAM |
| EP509 - CENTRAL UTILITY PLANT ELECTRICAL DETAILS |
| EP510 - GENERATOR REMOTE ANNUNCIATOR PANEL |
| EP511 - GENERATOR FUEL - OIL TRANSFER PUMP CONTROL ROOM |
| EP512 - GENERATOR ELEVATION DETAIL |
| EP513 - POWER MONITORING SYSTEM RISER DIAGRAM |
| EP514 - POWER MONITORING SYSTEM RISER DIAGRAM |
| EP515 - SWITCHBOARD ELEVATIONS |
| EP516 - MISCELLANEOUS CONNECTION DIAGRAMS |
| EP517 - ELECTRICAL DETAILS |
| EP518 - ELECTRICAL DETAILS |
| EP601 - SINGLE LINE DIAGRAMS - UTILITY SERVICE |
| EP602 - SINGLE LINE DIAGRAMS - CUP NORMAL POWER |
| EP603 - SINGLE LINE DIAGRAMS - CUP ESSENTIAL POWER |
| EP604 - SINGLE LINE DIAGRAMS - CUP ESSENTIAL POWER |
| EP605 - SINGLE LINE DIAGRAMS - HOSPITAL NORMAL POWER |
| EP606 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER |
| EP607 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER |
| EP608 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER |
| EP609 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER |
| EP610 - SINGLE LINE DIAGRAMS - CLINIC NORMAL POWER |
| EP611 - SINGLE LINE DIAGRAMS - CLINIC NORMAL POWER |
| EP612 - SINGLE LINE DIAGRAMS - CLINIC NORMAL POWER |
| EP613 - SINGLE LINE DIAGRAMS - CLINIC ESSENTIAL POWER |
| EP614 - SINGLE LINE DIAGRAMS - CLINIC ESSENTIAL POWER |
| EP615 - SINGLE LINE DIAGRAMS - PHOTOVOLTAICS |
| EP616 - SINGLE LINE DIAGRAMS - PHOTOVOLTAICS |
| EP617 - SINGLE LINE DIAGRAM - PHOTOVOLTAICS |
| EP618 - HOSPITAL ELECTRICAL GROUND BUS CONNECTION RISER |
| EP619 - OVERALL GROUNDING DIAGRAM |
| EP701 - ELECTRICAL SCHEDULES |
| EP702 - ELECTRICAL SCHEDULES |
| EP703 - ELECTRICAL SCHEDULES |
| EP704 - ELECTRICAL SCHEDULES |
| EP705 - ELECTRICAL SCHEDULES |
| EP706 - ELECTRICAL SCHEDULES |
| EP707 - ELECTRICAL SCHEDULES |
| EP800 - ELECTRICAL PANEL SCHEDULES |
| EP801 - ELECTRICAL PANEL SCHEDULES |
| EP802 - ELECTRICAL PANEL SCHEDULES |
| EP803 - ELECTRICAL PANEL SCHEDULES |
| EP804 - ELECTRICAL PANEL SCHEDULES |
| EP805 - ELECTRICAL PANEL SCHEDULES |
| EP806 - ELECTRICAL PANEL SCHEDULES |
| EP807 - ELECTRICAL PANEL SCHEDULES |
| EP808 - ELECTRICAL PANEL SCHEDULES |
| EP809 - ELECTRICAL PANEL SCHEDULES |
| EP810 - ELECTRICAL PANEL SCHEDULES |
| EP811 - ELECTRICAL PANEL SCHEDULES |
| EP812 - ELECTRICAL PANEL SCHEDULES |
| EP813 - ELECTRICAL PANEL SCHEDULES |
| EP814 - ELECTRICAL PANEL SCHEDULES |
| EP815 - ELECTRICAL PANEL SCHEDULES |
| EP816 - ELECTRICAL PANEL SCHEDULES |
| EP817 - ELECTRICAL PANEL SCHEDULES |
| EP818 - ELECTRICAL PANEL SCHEDULES |
| EP819 - ELECTRICAL PANEL SCHEDULES |
| EP820 - ELECTRICAL PANEL SCHEDULES |
| EP821 - ELECTRICAL PANEL SCHEDULES |
| EP822 - ELECTRICAL PANEL SCHEDULES |
| EP823 - ELECTRICAL PANEL SCHEDULES |
| EP824 - ELECTRICAL PANEL SCHEDULES |
| EP825 - ELECTRICAL PANEL SCHEDULES |
| EP826 - ELECTRICAL PANEL SCHEDULES |
| EP827 - ELECTRICAL PANEL SCHEDULES |
| EP828 - ELECTRICAL PANEL SCHEDULES |
| EP829 - ELECTRICAL PANEL SCHEDULES |
| EP830 - ELECTRICAL PANEL SCHEDULES |
| EP831 - ELECTRICAL PANEL SCHEDULES |
| EP832 - ELECTRICAL PANEL SCHEDULES |
| EP833 - ELECTRICAL PANEL SCHEDULES |
| EP834 - ELECTRICAL PANEL SCHEDULES |
| EP835 - ELECTRICAL PANEL SCHEDULES |
| EP836 - ELECTRICAL PANEL SCHEDULES |
| EP837 - ELECTRICAL PANEL SCHEDULES |
| EP838 - ELECTRICAL PANEL SCHEDULES |
| EP839 - ELECTRICAL PANEL SCHEDULES |
| EP840 - ELECTRICAL PANEL SCHEDULES |
| EP841 - ELECTRICAL PANEL SCHEDULES |
| EP842 - ELECTRICAL PANEL SCHEDULES |
| EP843 - ELECTRICAL PANEL SCHEDULES |
| EP844 - ELECTRICAL PANEL SCHEDULES |
| EP845 - ELECTRICAL PANEL SCHEDULES |
| 632 H-ET100s |
| H-ET110 - LEVEL 1 PUBLIC ADDRESS ZONE PLANS |
| H-ET110A - LEVEL 1, AREA A - COMMUNICATION ZONE ALLOCATION FLOOR PLAN |
| H-ET110B - LEVEL 1 , AREA B - COMMUNICATION ZONE ALLOCATION FLOOR PLAN |
| H-ET111 - LEVEL 1, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET112 - LEVEL 1, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET113 - LEVEL 1, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET114 - LEVEL 1, ZONE 4, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET115 - LEVEL 1, ZONE 5, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET120 - LEVEL 2 PUBLIC ADDRESS ZONE PLANS |
| H-ET120A - LEVEL 2, AREA A - COMMUNICATION ZONE ALLOCATION FLOOR PLAN |
| H-ET120B - LEVEL 2 , AREA B - COMMUNICATION ZONE ALLOCATION FLOOR PLAN |
| H-ET121 - LEVEL 2, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET122 - LEVEL 2, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET123 - LEVEL 2, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET124 - LEVEL 2, ZONE 4, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET125 - LEVEL 2, ZONE 5, FLOOR PLAN – TELECOMMUNICATIONS |
| H-ET130 - LEVEL 3 PUBLIC ADDRESS ZONE PLANS |
| H-ET130A - LEVEL 3 , AREA A - COMMUNICATION ZONE ALLOCATION FLOOR PLAN |
| H-ET130B - LEVEL 3 , AREA B - COMMUNICATION ZONE ALLOCATION FLOOR PLAN |
| H-ET131 - LEVEL 3, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET132 - LEVEL 3, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET133 - LEVEL 3, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET134 - LEVEL 3, ZONE 4, FLOOR PLAN – TELECOMMUNICATIONS |
| H-ET135 - LEVEL 3, ZONE 5, FLOOR PLAN – TELECOMMUNICATIONS |
| H-ET141 - LEVEL 4, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET142 - LEVEL 4, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET143 - LEVEL 4, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS |
| H-ET144 - LEVEL 4, ZONE 4, FLOOR PLAN – TELECOMMUNICATIONS |
| 634 H-ET400s |
| H-ET401 - ENLARGED FLOOR PLANS |
| H-ET402 - ENLARGED FLOOR PLANS |
| H-ET403 - ENLARGED FLOOR PLANS |
| H-ET404 - ENLARGED FLOOR PLANS |
| H-ET405 - ENLARGED FLOOR PLANS |
| H-ET406 - ENLARGED FLOOR PLANS |
| H-ET407 - ENLARGED FLOOR PLANS |
| H-ET408 - ENLARGED FLOOR PLANS |
| H-ET409 - ENLARGED FLOOR PLANS |
| H-ET410 - ENLARGED FLOOR PLANS |
| H-ET411 - ENLARGED FLOOR PLANS |
| H-ET412 - ENLARGED FLOOR PLANS |
| H-ET413 - ENLARGED FLOOR PLANS |
| H-ET414 - ENLARGED FLOOR PLANS |
| H-ET415 - ENLARGED FLOOR PLANS |
| H-ET416 - ENLARGED FLOOR PLANS |
| H-ET417 - ENLARGED FLOOR PLANS |
| H-ET418 - ENLARGED FLOOR PLANS |
| H-ET419 - ENLARGED FLOOR PLANS |
| H-EY111 - LEVEL 1, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| 636 ET500s-800s |
| ET501 - TELECOMMUNICATIONS DETAILS |
| ET502 - TELECOMMUNICATIONS DETAILS |
| ET503 - TELECOMMUNICATIONS DETAILS |
| ET504 - TELECOMMUNICATIONS DETAILS |
| ET505 - TELECOMMUNICATIONS DETAILS |
| ET506 - TELECOMMUNICATIONS DETAILS |
| ET601 - OUTSIDE PLANT CABLE ENTRANCE RISER DIAGRAM - ADN |
| ET602 - OUTSIDE PLANT CABLE ENTRANCE RISER DIAGRAM - HOSPITAL |
| ET603 - VOICE AND DATA BACKBONE RISER DIAGRAM - HOSPITAL |
| ET604 - VOICE AND DATA BACKBONE RISER DIAGRAM - CLINIC |
| ET605 - VOICE AND DATA HORIZONTAL CONNECTION DIAGRAM |
| ET606 - TELECOMMUNICATIONS RISER DIAGRAMS |
| ET607 - TELECOMMUNICATIONS GROUNDING DIAGRAM |
| ET608 - TELEVISION RISER DIAGRAM |
| ET609 - PUBLIC ADDRESS RISER DIAGRAM |
| ET610 - PUBLIC ADDRESS SYSTEM RISER DIAGRAM |
| ET801 - HOSPITAL NURSE CALL SCHEDULES |
| ET802 - HOSPITAL NURSE CALL SCHEDULES |
| ET803 - HOSPITAL NURSE CALL SCHEDULES |
| ET804 - CLINIC NURSE CALL SCHEDULES |
| ET805 - CLINIC NURSE CALL SCHEDULES |
| 638 H-EY100s |
| H-EY111 - LEVEL 1, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY112 - LEVEL 1, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY113 - LEVEL 1, ZONE 3, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY114 - LEVEL 1, ZONE 4, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY115 - LEVEL 1, ZONE 5, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY121 - LEVEL 2, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY122 - LEVEL 2, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY123 - LEVEL 2, ZONE 3, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY124 - LEVEL 2, ZONE 4, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY125 - LEVEL 2, ZONE 5, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY131 - LEVEL 3, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY132 - LEVEL 3, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY133 - LEVEL 3, ZONE 3, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY134 - LEVEL 3, ZONE 4, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY135 - LEVEL 3, ZONE 5, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY141 - LEVEL 4, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY142 - LEVEL 4, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM |
| H-EY143 - LEVEL4, ZONE 3 FLOOR PLAN - ELECTRONIC SECURITY SYSTEMS |
| H-EY144 - LEVEL4, ZONE 4 FLOOR PLAN - ELECTRONIC SECURITY SYSTEMS |
| 640 EY500s-800s |
| EY501 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY502 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY503 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY504 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY505 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY506 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY507 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY508 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY509 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY510 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY511 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY512 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY513 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY514 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY515 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY516 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY517 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY518 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY519 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY520 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY521 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY522 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY523 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY524 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY525 - ELECTRONIC SECURITY DOOR CONTROL DETAILS |
| EY601 - ELECTRONIC SECURITY DETAILS |
| EY602 - ELECTRONIC SECURITY DETAILS |
| EY701 - ELECTRONIC SECURITY SYSTEM NETWORK RISER DIAGRAM |
| EY702 - ELECTRONIC SECURITY SYSTEM NETWORK RISER DIAGRAM |
| EY703 - ELECTRONIC SECURITY SYSTEM TYPICAL CONNECTION DIAGRAMS |
| EY801 - ELECTRONIC SECURITY SCHEDULES |
| EY802 - ELECTRONIC SECURITY SCHEDULES |
| EY803 - ELECTRONIC SECURITY SCHEDULES |
| 642 H-FA100s |
| H-FA111 - LEVEL 1, ZONE 1, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA112 - LEVEL 1, ZONE 2, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA113 - LEVEL 1, ZONE 3, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA114 - LEVEL 1, ZONE 4, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA115 - LEVEL 1, ZONE 5, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA121 - LEVEL 2, ZONE 1, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA122 - LEVEL 2, ZONE 2, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA123 - LEVEL 2, ZONE 3, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA124 - LEVEL 2, ZONE 4, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA125 - LEVEL 2, ZONE 5, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION |
| H-FA131 - LEVEL 3, ZONE 1, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA132 - LEVEL 3, ZONE 2, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA133 - LEVEL 3, ZONE 3, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA134 - LEVEL 3, ZONE 4, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION |
| H-FA135 - LEVEL 3, ZONE 5, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION |
| H-FA141 - LEVEL 4, ZONE 1, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION |
| H-FA142 - LEVEL 4, ZONE 2, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION |
| H-FA143 - LEVEL 4, ZONE 3, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION |
| H-FA144 - LEVEL 4, ZONE 4, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION |
| 644 FA600s |
| FA601 - TYPICAL FIRE ALARM CONNECTION DIAGRAM |
| FA602 - TYPICAL FIRE ALARM DEVICE CONNECTION DIAGRAM |
| FA603 - TYPICAL FIRE ALARM CONNECTION DIAGRAM |
| FA604 - FIRE ALARM MASS NOTIFICATION SEQUENCE OF OPERATION |
| FA605 - FIRE ALARM MASS NOTIFICATION SEQUENCE OF OPERATION |
| 646 H-EQ100s |
| H-EQ15A - LIGHTNING PROTECTION PLAN - HOSPITAL |
| H-EQ15B - LIGHTNING PROTECTION PLAN - CLINIC |
| 648 EQ400s-500s |
| EQ401 - LIGHTNING PROTECTION ENLARGED PLANS |
| EQ501 - LIGHTNING PROTECTION DETAILS |
| EQ502 - LIGHTNING PROTECTION DETAILS |
| EQ503 - LIGHTNING PROTECTION DETAILS |