Drwgs_Vol_6E_6shts_W912PL-12-R-0008.pdf

PDF 14 MB Posted

Attached to
Fort Irwin Replacement Hospital, Fort Irwin, San Bernardino County, California
Solicitation number
W912PL-12-R-0008
Issued by

About this file

Drawings - Volume 6E

View the file

Other files

File Type Posted
am9_W912PL-12-R-0008.pdf PDF
am8_W912PL-12-R-0008.pdf PDF
Amended J A Redacted Version_13Feb2012.pdf PDF
am7_W912PL-12-R-0008.pdf PDF
am7_W912PL-12-R-0008.pdf PDF
PART2of4AM-06_DRAW.pdf PDF
PART4of4AM-06_DRAW.pdf PDF
PART3of4AM-06_DRAW.pdf PDF
PART1of4AM-06_DRAW.pdf PDF
am6_W912PL-12-R-0008.pdf PDF
PART2of3-DRAW-AM 5 - 02-02-12.pdf PDF
PART1of3-DRAW-AM 5 - 02-02-12.pdf PDF
AM-05_SPECS.pdf PDF
PART3of3-DRAW-AM 5 - 02-02-12.pdf PDF
am4_W912PL-12-R-0008.pdf PDF
Hospital Business Forum-Site Walk Attendee list 01-18-12.pdf PDF
am3_W912PL-12-R-0008.pdf PDF
am2_W912PL-12-R-0008.pdf PDF
am1_W912PL-12-R-0008.pdf PDF
J A_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_5A_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_5B_150 shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1F_30 shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3D_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_4B_97shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_4A_150shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1C_25shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1D_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_5C_202shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6F_5shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_2B_173shts_W912PL-12-R-0008.pdf PDF
Spec_Vol 1_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6D_112shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6C_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6A_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3A_25shts_W912PL-12-R-0008.pdf PDF
Spec_Vol 3_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_6B_100shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3C_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1E_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_2A_200shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3E_105shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1A_50shts_W912PL-12-R-0008.pdf PDF
Spec_Vol 2_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_1B_50shts_W912PL-12-R-0008.pdf PDF
Drwgs_Vol_3B_25shts_W912PL-12-R-0008.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FACP/FMCP

FAAP RM 2134

FAPS-H2A

FAPS-H3A

FAPS-H1A

FAPS-H2B

FAPS-H3B

FAPS-H1B

RM 1112

RM 2115

RM 3121

RM 1212

RM 2206

RM 3222

SMOKE WALL

NAC-H3B

SERVES

ZONE 3B

NAC-HP

SERVES HOSPITAL

PENTHOUSE

NAC-H3A

DAL

H31LS1-

SLC-H3

SLC-H3

SLC-H3

SLC-H3 SLC-H3

DA

L

NAC-H2B

SERVES

ZONE 2B

SERVES

ZONE 2A

NAC-H2A

H21LS1-

SLC-H2

SLC-H2 SLC-H2

DAL

DA

L

DAL

SLC-H2

SLC-H2

RM 2301

H21LS1-

NAC-H1B

SERVES

ZONE 1B

H11LS1-

SLC-H1

DAL

NAC-H1A

SLC-H1

SLC-H1

SERVES

ZONE 1A

SLC-H1

SLC-H1

DAL

SERVES

ZONE 3A

H32LS1-

H22LS1-

SMOKE ZONE A SMOKE ZONE B

SLC-HP

SERVES HOSPITAL

PENTHOUSE

FAPS-C2

FAPS-C3

FAPS-C1

RM 1404

RM 2464

RM 3437

NAC-C3

SLC-C3

SLC-C3

DAL

NAC-C2

SLC-C2

SLC-C2

NAC-C1

SLC-C1

SLC-C1

SERVES 3RD

FLOOR

CLINIC

C34LS1-3

C15LS2-9

C24LS1-6

SERVES

2ND FLOOR

CLINIC

SERVES 1ST

FLOOR

CLINIC

SERVES 3RD

FLOOR

HOSPITAL

SERVES 2ND

FLOOR

HOSPITAL

DAL

DA

L

SLC-C2

DAL

SERVES 1ST

FLOOR

HOSPITAL

FIRST FLOOR

SECOND FLOOR

THIRD FLOOR

PENTHOUSE

ROOF

HOSPITAL CLINIC

SLC-CP

NAC-CP

SERVES CLINIC

PENTHOUSE

NAC-C1B SLC-C1NOTIFICATION APPLIANCE CIRCUIT (NAC) SIGNALING LINE CIRCUIT (SLC)

DAL DIGITAL AUDIO LOOP (DAL), 2 HOUR RATED

CABLE INSTALLED IN METAL CONDUIT

INDICATES FLOOR: 1-FIRST FLOOR,

2-SECOND FLOOR, 3-THIRD FLOOR,

P-PENTHOUSE

INDICATES OCCUPANCY: C-CLINIC,

H-HOSPITAL, P-CENTRAL UTILITY

PLANT

NOTIFICATION APPLIANCE CIRCUIT

INDICATES FLOOR: 1-FIRST FLOOR,

2-SECOND FLOOR, 3-THIRD FLOOR,

P-PENTHOUSE

INDICATES OCCUPANCY: C-CLINIC,

H-HOSPITAL, P-CENTRAL UTILITY

PLANT

SIGNALING LINE CIRCUIT

LINE CODE LEGEND

SLC-C3

INDICATES SMOKE ZONE WHERE

APPLICABLE

SLC-C1

SLC-CP

NAC-CP

SERVES CLINIC

PENTHOUSE

FAPS-P

NAC-P

SLC-P

PLS1B-17

SERVES CUP

SL

C-

P

DA

L

DA

L

CENTRAL UTILITY PLANT

RM P1112

SLC-C1 INDICATES TWO HOUR FIRE

RATED CABLE IN METAL

CONDUIT

H11LS1-

FAAP

RM 1548

SLC-H1BSLC-H1A

SLC-H2A

SLC-H3A

SLC-H2B

SLC-H3B

MNOC

MNOC

RM 1548

RM 2134

2 2

2 2

RADIO TRANSMITTER ANTENNA.

SEE 2/FA603 FOR DETAIL.

FARP

H21LS1-16

H21LS1-15

6 8

MNOC

MNOC

RM 11C03

RM 14C03

MNOC RM 2130

MNOC RM 2301

MNOC RM 24C01

MNOC RM 31C03

MNOC RM 33C08

25S01

34S01

SLC-C3

MNOC RM P1114

SHEET NOTES:

NOTES:

KEY NOTES 00

Sheet Reference Number

AP

PR

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

NO

S

CA

LE

FA601

TY

PI

CA

L F

IR

E

AL

AR

M

CO

NN

EC

TI

ON

D

IA

GR

AM

RL

W

RL

W

KL

M

FA

NO SCALE1 TYPICAL FIRE ALARM CONNECTION DIAGRAM

1 TYPICAL NOTIFICATION APPLIANCE

CIRCUIT(S) AS REQUIRED TO SERVE

SPEAKERS AND STROBES. SEE 2/FA602 FOR

CONNECTION DIAGRAM.

2 TYPICAL SIGNALING LINE CIRCUIT(S) AS

REQUIRED. SEE 2/FA602 FOR CONNECTION

DIAGRAM.

3 REMOTE POWER SUPPLY/AMPLIFIER

CABINET(S) CONSISTING OF DIGITAL AUDIO

AMPLIFIER, POWER SUPPLIES, BATTERIES

AND CONTROL MODULES. SEE 2/FA602 FOR

CONNECTION DIAGRAM.

4 3/4" CONDUIT WITH RADIO TRANSMITTER

ANTENNA WIRING AS REQUIRED.

5 ROUTE FIRE ALARM CIRCUITS THROUGH

MECHANICAL UTILITY CANOPY BETWEEN

BUILDINGS. PROVIDE SURGE PROTECTION

ON ALL CIRCUITS AT BOTH ENDS.

6 THE VOICE NOTIFICATION SYSTEM SHALL BE

INDEPENDANT OF THE FIRE ALARM SYSTEM

AND BE CAPABLE OF AUTONOMOUS

OPERATION. THE VOICE NOTIFICATION

SYSTEM SHALL BE HOUSED IN A SEPERATE

PANEL THAT CONTAINS AN INDEPENDANT

POWER SUPPLY AND BATTERIES. IT IS

SHOWN AS A SINGLE PANEL FOR CLARITY

ONLY.

7 ONE CIRCUIT SHALL SERVE THE FIRE ALARM

CONTROL PANEL/MASS NOTIFICATION

CONTROL PANEL AND THE OTHER CIRCUIT

SHALL SERVE THE VOICE NOTIFICATION

SYSTEM PANEL POWER SUPPLIES.

8 PROVIDE WITH BATTERY BACK-UP AS

DESCRIBED IN SPECIFICATIONS SECTION

283176, PARAGRAPH 2.13.

A.

B.

C.

INSTALL ALL FIRE ALARM SYSTEM WIRING IN

3/4" CONDUIT UNLESS NOTED OTHERWISE.

CONDUIT SIZES AND QUANTITIES ARE SHOWN

FOR BIDDING PURPOSES ONLY. PROVIDE

CONDUIT SIZES, QUANTITES AND

CONFIGURATION IN ACCORDANCE WITH THE

MANUFACTURERS APPROVED SHOP

DRAWINGS.

HOSPITAL PORTION OF THE FIRE ALARM

SYSTEM SHALL BE A SURVIVABLE LEVEL 3

CABLE SYSTEM INSTALLED IN METAL CONDUIT.

SY

M

D E S

C R

IP

TI

O N

D

AT

E

FIRE ALARM SYSTEM MONITOR

MODULE FOR SUPERVISION OF

120V CONTROL CIRCUIT SERVING

THE ELEVATOR SHUNT TRIP

DEVICE. UPON LOSS OF POWER

AT THE CONTROL RELAY "FR", A

SUPERVISORY SIGNAL SHALL

ANNUNCIATE AT THE FIRE ALARM

CONTROL PANEL AND REMOTE

ANNUNCIATOR. MOUNT WITHIN

36" OF THE ELEVATOR

DISCONNECT.

FIRE ALARM CONTROL MODULE WITH FORM C

ADDRESSABLE RELAY AND CONTACTS RATED

FOR 5A, 120VAC. MOUNT IN A 4" SQUARE BOX

AND PROVIDE SOLID BARRIER TO SEPARATE

THE POWER LIMITED AND NON POWER

LIMITED WIRING. CONTACT SHALL CLOSE

UPON ACTIVATION OF DEVICES AS INDICATED

ON THE FIRE ALARM SEQUENCE OF

OPERATION. MOUNT WITHIN 36" OF THE

ELEVATOR CONTROL SWITCH. FIRE ALARM SIGNALING

LINE CIRCUIT.

MAIN DISCONNECT

ST

ST

ST

SHUNT TRIP

FUSES

PL

FR

ST

CR

KEY TEST SWITCH

LINE LOAD

FUSE FUSE

FUSE

CONTROL POWER

TRANSFORMERUL LISTED ELEVATOR CONTROL SWITCH WITH

FUSED PROTECTION FOR ELEVATOR AND SHUNT

TRIP MECHANISM. PROVIDE INTEGRAL 480V-120V

CONTROL POWER TRANSFORMER, KEY OPERATED

TEST SWITCH, FIRE SAFETY INTERFACE RELAY "CR"

(FOR ACTIVATION OF THE SHUNT TRIP FROM THE

FIRE ALARM SYSTEM), RED PILOT LIGHT "PL" (FOR

POWER "ON" INDICATION), AND SHUNT TRIP

VOLTAGE MONITORING RELAY "FR" (FOR

MONITORING OF THE SHUNT TRIP CIRCUIT FROM THE

FIRE ALARM SYSTEM). UNIT SHALL HAVE A 200,000A

SHORT CIRCUIT RATING. PROVIDE MAIN FUSES IN

ACCORDANCE WITH THE ELEVATOR MANUFACTURES

RECOMMENDATIONS.

FR

FA

LEGEND

PILOT LIGHT TO VISUALLY INDICATE PRESENCE OF CONTROL

VOLTAGE.

SHUNT TRIP VOLTAGE MONITORING RELAY.

SHUNT TRIP COIL.

CONTROL RELAY TO ISOLATE THE FIRE ALARM CONTACTS "FA"

FROM THE SHUNT TRIP COIL DUTY.

CR

PL

FR

ST

CR

P

AOM

DH

AIM

TS

AIM

FS

AOM

AHU1.1

ST-AHU1.1

AOM

VFD1

VFD

VFD1

6SIGNALING LINE CIRCUIT (SLC)

AOMEL

INSTALL ALL WIRING IN 3/4" CONDUIT UNLESS OTHERWISE NOTED.

AOM

AOM

AOM

AD

AOM

DL

AIM

EL

EL4

FACP NOTE:

DH

AOMAIMAOMAIM

TS

PIV

AOM

FAPS

NOTIFICATION APPLIANCE

CIRCUIT (NAC)

AOM

AIM

THE DESIGNATED LEVEL FOR ELEVATOR RECALL SHALL BE LEVEL 2. ALTERNATE LEVEL #1 SHALL BE LEVEL 1. ALTERNATE LEVEL #2 SHALL BE LEVEL 3. ALTERNATE LEVEL #3 SHALL BE LEVEL 4 FOR ELEVATOR 8 ONLY. WHERE AN INITIATING DEVICE ACTIVATES ELEVATOR RECALL, THE ELEVATOR SHALL RECALL TO THE DESIGNATED LEVEL. IF THE DESIGNATED LEVEL LOBBY SMOKE DETECTOR IS IN ALARM, THEN THE ELEVATOR

SHALL RECALL TO THE NEXT AVAILABLE ALTERNATE LEVEL NOT IN ALARM.

DEFINITIONS:

DESIGNATED LEVEL – THE PRIMARY LEVEL OF RECALL FOR FIREFIGHTERS’ SERVICE AS DESCRIBED IN NFPA 72, CHAPTER 21.3.

ALTERNATE LEVEL – A LEVEL OTHER THAN THE DESIGNATED LEVEL AS DESCRIBED IN NFPA 72, CHAPTER 21.3.

ELEVATOR RECALL PRIORITY

TYP. SPEAKER IN

STAIRWELL

NOTIFICATION APPLIANCE

CIRCUIT (NAC)

TYP. JUNTION BOX

LOCATED IN ELEVATOR

MACHINE ROOM

ELEVATOR TRAVELING CABLE

E TYP. ELEVATOR CAB

SPEAKER

AOM

AIM

FM-200

FM-200

AIM

38 40

AOM

FCU/FDDC

H1KLQ1C-24

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ1C-15

NOTE: ALL SHUNT TRIP WIRING SHALL BE #12 AWG. PROVIDE WIRING IN 1/2" CONDUIT.

FIRE ALARM CONTROL

MODULE CONTACT

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ1C-19

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ1C-23

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ1C-16

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ1C-20

H1KLQ2C-35

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ2C-3

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ2C-7

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ2C-11

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ2C-6

C

SHUNT TRIP COIL,

CIRCUIT H1KLQ2C-10

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

FIRE ALARM CONTROL

MODULE CONTACT

NOTES:

KEY NOTES 00

Sheet Reference Number

AP

PR

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

NO

T

TO

S

CA

LE

FA602

TY

PI

CA

L F

IR

E

AL

AR

M

DE

VI

CE

C

ON

NE

CT

IO

N

DI

AG

RA

M

RL

W

RL

W

KL

M

FA

NTS1 ELEVATOR SHUTDOWN INTERFACE DIAGRAM

19 PROVIDE MONITOR MODULES FIRE PUMP

ALARM SIGNALS AS INDICATED ON THE FIRE

ALARM SEQUENCE OF OPERATION MATRIX.

PROVIDE QUANTITY AS REQUIRED. MOUNT

MODULE WITHIN 36" OF FIRE PUMP

CONTROL PANEL. REFER TO SHEET FA604

AND FA605 FOR FIRE ALARM SYSTEM

SEQUENCE OF OPERATION MATRIX.

20 TYPICAL DOOR ACCESS CONTROL SYSTEM

EQUIPMENT CABINET.

21 CONTROL MODULE FOR DEACTIVATION OF

DOOR LOCKS IN EGRESS PATHS. MODULE

SHALL BE LOCATED WITHIN 36" OF ACCESS

CONTROL SYSTEM EQUIPMENT CABINET.

22 TYPICAL CONNECTION TO KITCHEN

EQUIPMENT GAS SUPPLY SOLENOID VALVE.

MOUNT WITHIN 36" OF DEVICE IT SERVES.

23 CONTROL MODULE FOR SHUT-OFF OF GAS

SUPPLY TO KITCHEN EQUIPMENT.

24 TYPICAL CONNECTION TO KITCHEN HOOD

FIRE SUPPRESSION SYSTEM.

25 LOCATE MONITOR MODULE WITHIN 36" OF

KITCHEN HOOD WHICH IT SERVES.

26 TYPICAL CONNECTION TO SHUNT TRIP COIL

IN CIRCUIT BREAKER SERVING KITCHEN

EQUIPMENT.

27 CONTROL MODULE FOR ACTIVATION OF

SHUNT TRIP COIL IN CIRCUIT BREAKER

SERVING KITCHEN EQUIPMENT. MOUNT

WITHIN 36" OF DEVICE IT SERVES.

28 CONTROL MODULE FOR INTERFACE WITH

THE DATA CENTER MASTER CONTROL

PANEL. MOUNT WITHIN 36" OF CONTROL

PANEL.

29 DATA CENTER COMPUTER ROOM AIR

CONDITIONING UNIT (CAC) MASTER

CONTROL PANEL.

30 TYPICAL HVAC SYSTEM "DDC" PANEL.

31 CONTROL MODULE FOR FIRE ALARM

INTERFACE WITH HVAC CONTROL SYSTEM.

PROVIDE A CONTROL MODULE FOR EACH

HVAC SYSTEM CONTROL PANEL. THE

CONTROL MODULE SHALL ALERT THE HVAC

CONTROL SYSTEM OF A FIRE ALARM FAN

SHUT-DOWN EVENT. MOUNT MODULE

WITHIN 36" OF HVAC CONTROL PANEL.

32 FIRE PUMP CONTROL PANEL.

33 REFER TO P-FA112 FOR LOCATION.

34 CONTROL MODULE FOR ACTIVATION OF

FM-200 CLEAN AGENT SYSTEM CONTROL

PANEL. MOUNT WITHIN 36" OF CONTROL

PANEL.

35 MONITOR MODULE FOR MONITORING OF

FM-200 CLEAN AGENT CONTROL PANEL.

MOUNT WITHIN 36" OF CONTROL PANEL.

36 CLEAN AGENT CONTROL PANEL "FM-200".

37 TYPICAL MONITOR MODULE FOR

SUPERVISION OF THE FIRE PUMP CIRCUIT

BREAKER DISCONNECTING MEANS. MOUNT

WITHIN 36" OF CIRCUIT BREAKER. A

SUPERVISORY SIGNAL SHALL BE SENT

WHENEVER THE CIRCUIT BREAKER IS

PLACED IN THE "OPEN" POSITION.

38 TYPICAL CIRCUIT BREAKER

DISCONNECTING MEANS SERVING THE FIRE

PUMP CONTROLLER/AUTOMATIC TRANSFER

SWITCH.

39 TYPICAL CONTROL MODULE FOR FAN COIL

UNIT SHUTDOWN. MOUNT WITHIN 36" OF

FAN COIL UNIT CONTROLLER.

40 TYPICAL FAN COIL UNIT CONTROLLER.

1 TYPICAL MOTOR STARTER SERVING HVAC

SYSTEM FAN.

2 CONTROL MODULE FOR FAN SHUT-DOWN.

LOCATE WITHIN 36" OF MOTOR STARTER OR

VARIABLE FREQUENCY DRIVE.

3 TYPICAL VARIABLE FREQUENCY DRIVE

SERVING HVAC SYSTEM FAN.

4 CONTROL MODULE SHALL RELEASE THE

HOLD-OPEN DOORS UPON ACTIVATION OF

THE FIRE ALARM SYSTEM. MODULE SHALL

BE LOCATED ABOVE FINISHED ACCESSIBLE

CEILING WITHIN 36" OF DOOR. WHERE

CEILING SPACE IS NOT ACCESSIBLE THE

MODULE SHALL BE FLUSH MOUNTED IN THE

CEILING WITHIN 36" OF DOOR.

5 TYPICAL 24V DOOR HOLD-OPEN DEVICE

SUPPLIED WITH DOOR HARDWARE.

POWERED FROM THE FIRE ALARM SYSTEM.

6 CONNECT TO ADDITIONAL DEVICES, SEE

FIRE ALARM FLOOR PLANS FOR QUANTITY.

7 LOCATE MONITOR MODULE WITHIN 36" OF

THE FLOW OR TAMPER SWITCH WHICH IT

SERVES.

8 TYPICAL ELEVATOR CONTROLLER.

9 PROVIDE THREE CONTROL MODULES FOR

EACH ELEVATOR CONTROLLER FOR THE

FOLLOWING FUNCTIONS: MOUNT WITHIN 36"

OF ELEVATOR CONTROLLER.

a. EL1 - MODULE SHALL ACTIVATE RECALL

TO THE DESIGNATED LEVEL FOR

ACTUATION OF ELEVATOR LOBBY SMOKE

DETECTORS OTHER THAN THE DESIGNATED

LEVEL LOBBY.

b. EL2 - MODULE SHALL ACTIVATE RECALL

TO THE ALTERNATE LEVEL FROM

ACTUATION OF ELEVATOR LOBBY SMOKE

DETECTORS AT THE DESIGNATED LEVEL

LOBBY.

c. EL3 - MODULE SHALL ACTIVATE THE

FIREFIGHTERS HELMET SIGNAL WHEN

RECALL IS INITIATED BY THE SMOKE

DETECTOR IN THE ELEVATOR MACHINE

ROOM OR HOISTWAY.

10 CONTROL MODULE FOR ACTIVATION OF THE

POCKET MOUNTED FIRE DOOR. CONTROL

MODULE SHALL TRIGGER THE DOOR TO

AUTOMATICALLY CLOSE UPON ACTIVATION

OF THE BUILDING'S FIRE ALARM SYSTEM.

MOUNT THE CONTROL MODULE WITHIN 36"

OF THE FIRE DOOR CONTROL PANEL.

11 CONTROL MODULE FOR ACTIVATION OF

ELEVATOR SHUNT TRIP DEVICE. MOUNT

WITHIN 36" OF ELEVATOR SWITCH. SEE

1/FA602 FOR CONNECTION DIAGRAM.

12 TYPICAL POCKET FIRE DOOR CONTROLLER.

13 ELEVATOR CONTROL SWITCH. SEE 1/FA602

FOR CONNECTION DIAGRAM.

14 TYPICAL AUTOMATIC DOOR OPERATOR

LOCATED IN CORRIDOR RATED WALL.

15 CONTROL MODULE SHALL DEACTIVATE THE

AUTOMATIC DOOR UPON ACTIVATION OF

THE FIRE ALARM SYSTEM. MODULE SHALL

BE LOCATED ABOVE FINISHED ACCESSIBLE

CEILING WITHIN 36" OF DOOR CONTROLLER.

WHERE CEILING SPACE IS NOT ACCESSIBLE,

THE MODULE SHALL BE FLUSH MOUNTED IN

THE CEILING WITHIN 36" OF THE DOOR

CONTROLLER.

16 MONITOR MODULE FOR MONITORING OF

THE ELEVATOR SHUNT TRIP POWER

CIRCUIT. MOUNT WITHIN 36" OF ELEVATOR

SWITCH. SEE 1/FA602 FOR CONNECTION

DIAGRAM.

17 TYPICAL FIRE ALARM POWER

SUPPLY/AMPLIFIER CABINET SERVING

NOTIFICATION DEVICES. SEE SHEET

1/FA601 AND 1/FA603 FOR ADDITIONAL

CONNECTIONS AND REQUIREMENTS.

18 SIGNALING LINE CIRCUIT (SLC) BACKBONE

NTS2 TYPICAL FIRE ALARM DEVICE CONNECTION DIAGRAM

NOT TO SCALE3 KITCHEN EQUIPMENT SHUNT TRIP WIRING DIAGRAMS

SY

M

D E S

C R

IP

TI

O N

D

DAA FCPS

C C

I

I

120V LIFE SAFETY CIRCUIT, SEE SHEET

FA601

CONTROL MODULE

FOR ACTIVATION

OF STROBES

INCOMING SIGNALING LINE CIRCUIT

(SLC) BACKBONE FROM FACP/FMCP

AUDIO CONTROL LOOP

TO ADDITIONAL FAPS

CLASS A BACKBONE WIRING

DIGITAL AUDIO AMPLIFIER

WITH BATTERY BACKUP

TYPICAL ISOLATION MODULE

TYPICAL REMOTE FIRE

ALARM CONTROL UNIT

AUDIO CONTROL LOOP

TO ADDITIONAL FAPS

OUTGOING SIGNALING LINE CIRCUIT

(SLC) BACKBONE TO FACP/FMCP

CLASS A BACKBONE

WIRING

POWER SUPPLIES WITH

BATTERY BACKUP

TYPICAL CLASS A SPEAKER

CIRCUIT SERVING SMOKE ZONE.

TYPICAL CLASS A STROBE

CIRCUIT SERVING SMOKE ZONE.

TYPICAL NOTIFICATION APPLIANCE CIRCUIT,

SEE SHEET FA601 FOR QUANTITY OF CIRCUITS.

TYPICAL CLASS A SIGNALING LINE

CIRCUIT AND POWER CIRCUIT SERVING

SMOKE ZONE DEVICES, SEE SHEET

FA601 FOR QUANTITY OF CIRCUITS.

CONTROL MODULE

FOR ACTIVATION

OF SPEAKERS

NOTES:

KEY NOTES 00

Sheet Reference Number

AP

PR

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

NT

S

FA603

TY

PI

CA

L F

IR

E

AL

AR

M

CO

NN

EC

TI

ON

D

IA

GR

AM

RL

W

RL

W

KL

M

FA

NTS1 FIRE ALARM REMOTE POWER SUPPLY/AMPLIFIER CABINET (FAPS) CONNECTION DIAGRAM

NTS2 FIRE ALARM TRANSMITTER ANTENNA MOUNTING DETAIL

1 FIRE ALARM SYSTEM ANTENNA.

2 TWO HOLE CONDUIT STRAP.

3 LIGHTNING ARRESTOR MOUNTED ON

ANTENNA MAST.

4 ANTENNA CABLE.

5 TYPICAL WEATHER HEAD.

6 1 5/8" SQUARE CHANNEL STEEL.

MECHANICALLY SECURE TO ANTENNA

MOUNTING RACK AS REQUIRED.

7 ANTENNA CABLE DOWN TO FIRE ALARM

RADIO TRANSMITTER PANEL IN ROOM 2134.

SEE H-FA121 FOR LOCATION. ROUTE

ANTENNA CABLE IN 1" CONDUIT FROM

ROOM 4102 TO FIRE ALARM RADIO

TRANSMITTER.

8 PROVIDE #6 AWG INSULATED COPPER

GROUND CONDUCTOR. BOND TO NEAREST

COMMUNICATIONS GROUND BUS (TGB).

9 ANTENNA MAST.

10 SEE H-AE547 FOR RACK DETAIL.

11 TYPICAL CONDUIT TO COMMUNICATIONS

ROOM 4102. SEE SHEET H-ET141 FOR

ADDITIONAL INFORMATION.

SY

M

D E S

C R

IP

TI

O N

D

FIRE ALARM SYSTEM

SEQUENCE OF OPERATION MATRIX

SYSTEM INPUTS

SY

ST

EM

O

UT

PU

TS

ACTIVATE FIRE ALARM NOTIFICATION APPLIANCE

STROBE LIGHTS AND SPEAKERS (SEE NOTE B AND

E)

MA

NU

AL

P

UL

L S

TA

TI

ON

W

AT

ER

F

LO

W

S W

IT

CH

SP

RI

NK

LE

R

VA

LV

E

TA

MP

ER

S

W

IT

CH

W

AT

ER

F

LO

W

S W

IT

CH

EL

EV

AT

OR

MA

CH

IN

E

RO

OM

CO

MP

UT

ER

R

OO

M

DU

CT

M

OU

NT

ED

SM

OK

E

DE

TE

CT

OR

GR

OU

ND

F

AU

LT

CO

ND

UC

TO

R

BR

EA

K

DISPLAY ALARM INDICATION AT FACP AND FAAP

TRANSMIT ALARM SIGNAL TO THE FIRE

DEPARTMENT

RECORD INFORMATION ON CPU

EL

EV

AT

OR

M

AC

HI

NE

R

OO

M

SM

OK

E

DE

TE

CT

OR

EL

EV

AT

OR

LO

BB

Y

SM

OK

E

DE

TE

CT

OR

PR

IM

AR

Y

LE

VE

L

EL

EV

AT

OR

LO

BB

Y

SM

OK

E

DE

TE

CT

OR

AL

TE

RN

AT

E

LE

VE

L

AR

EA

S

MO

KE

D

ET

EC

TO

RS

SM

OK

E

DE

TE

CT

OR

A

T

HE

LD

O

PE

N

SM

OK

E

DO

OR

O

R

FI

RE

S

HU

TT

ER

DU

CT

M

OU

NT

ED

S

MO

KE

D

ET

EC

TO

R

AC

TI

VA

TI

ON

O

F

LO

CA

L O

PE

RA

TO

RS

CO

NS

OL

E

PR

E-

RE

CO

RD

ED

M

ES

SA

GE

(L

OC

MA

SS

N

OT

IF

IC

AT

IO

N

LIV

E

VO

IC

E

ME

SS

AG

E

(L

OC

EL

EV

AT

OR

S

HU

NT

T

RI

P

CO

IL

LO

SS

O F

PO

W

ER

PO

ST

IN

DI

CA

TI

NG

V

AL

VE

KI

TC

HE

N

HO

OD

S

UP

PE

SI

ON

S

YS

TE

M

DISPLAY SUPERVISION CONDITION AT FACP AND

FAAP

TRANSMIT SUPERVISORY SIGNAL TO THE FIRE

DEPARTMENT

DISPLAY TROUBLE CONDITION AT FACP AND FAAP

TRANSMIT TROUBLE SIGNAL TO BASE FIRE

DEPARTMENT

DE-ENERGIZE HELD OPEN DOORS IN ASSOCIATED

SMOKE ZONE

INITIATE ELEVATOR RECALL, PRIMARY LEVEL

INITIATE ELEVATOR RECALL, ALTERNATE LEVEL

ACTIVATE MASS NOTIFICATION STROBES

OVERRIDE PRE-RECORDED DIGITIZED VOICE

MESSAGE

SHUT DOWN AIR HANDLING UNITS AND EXHAUST

FANS ON FLOOR IN ALARM

DISCONNECT POWER TO ASSOCIATED ELEVATOR

SHUT DOWN KITCHEN HOOD AIR SUPPLY FAN

OVERRIDE THE LOCAL OPERATING CONSOLE

ACTIVATE CLOSURE OF FIRE PARTITION

SHUT DOWN COMPUTER ROOM POWER PANEL 19

FI

RE

A

LA

RM

S

YS

TE

M

LIV

E

VO

IC

E

ME

SS

AG

E

AC

TI

VA

TI

ON

O

F

MA

SS

N

OT

IF

IC

AT

IO

N

SY

ST

EM

A

UT

ON

OM

OU

S

CO

NT

RO

L

UN

IT

P

RE

-R

EC

OR

DE

D

ME

SS

AG

E

AC

TI

VA

TI

ON

O

F

AR

EA

O

F

RE

FU

GE

TE

LE

PH

ON

E

ST

AT

IO

N

SM

OK

E

DE

TE

CT

OR

A

T

FI

RE

P

AR

TI

TI

ON

FI

RE

P

UM

P

RU

NN

IN

G

FI

RE

P

UM

P

LO

SS

O

F

PH

AS

E

FI

RE

P

UM

P

PH

AS

E

RE

VE

RS

AL

AC

TI

VA

TI

ON

O

F

MA

SS

N

OT

IF

IC

AT

IO

N

SY

ST

EM

A

UT

ON

OM

OU

S

CO

NT

RO

L

UN

IT

LI

VE

V

OI

CE

M

ES

SA

GE

FI

RE

P

UM

P

CO

NE

CT

ED

T

O

AL

TE

RN

AT

E

SO

UR

CE

A B C D E F G H I J K L M N O P Q R S T U V W X Y AA BB

AC

TI

VA

TI

ON

O

F

TH

E

CO

MP

UT

ER

RO

OM

C

LE

AN

A

GE

NT

S

YS

TE

M

DD

CO

MP

UT

ER

R

OO

M

CL

EA

N

AG

EN

T

SY

ST

EM

C

OM

MO

N

TR

OU

BL

E

CC EE

FI

RE

P

UM

P

DI

SC

ON

NE

CT

O

PE

N

SHEET NOTES:

NOTES:

Sheet Reference Number

AP

PR

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1 :

FA604

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

TI

ON

S

EQ

UE

NC

E

OF

O

PE

RA

TI

ON

RL

W

RL

W

KL

M

FA

A. THE HVAC SYSTEMS THE SURGERY AREA SHALL

BE SHUT DOWN ONLY BY SUPPLY DUCT

MOUNTED

SMOKE DETECTORS SERVING THE SURGERY

AREA.

B. CLINIC: THE CLINIC PORTION OF THE FACILITY

SHALL USE A GENERAL ALARM EVACUATION

SCHEME. UPON ACTIVATION OF THE SYSTEM

INPUTS AS INDICATED ON THIS MATRIX, ALL OF

THE FIRE ALARM NOTIFICATION APPLIANCE

STROBES AND SPEAKERS SHALL BE ACTIVATED

THROUGHOUT THE ENTIRE CLINIC. THE VOICE

ALARM MESSAGE IN THE CLINIC SHALL EVACUATE

THE ENTIRE CLINIC. A CODED AUDIO MESSAGE

SHALL BE DISTRIBUTED TO THE FIRE ALARM

SPEAKERS IN THE HOSPITAL AND CUP, THE

STROBES LOCATED OUTSIDE OF THE CLINIC

SMOKE ZONES SHALL NOT BE ACTIVATED. THE

CODED MESSAGE SHALL BE AS DIRECTED BY THE

CONTRACTING OFFICER AND POST FIRE CHIEF.

HOSPITAL: THE HOSPITAL PORTION OF THE

FACILITY SHALL USE A "DEFEND IN PLACE" TYPE

PARTIAL EVACUATION SCHEME FOR THE HOSPITAL

OCCUPANCY ONLY. UPON ACTIVATION OF THE

SYSTEM INPUTS AS INDICATED ON THIS MATRIX,

ONLY THE FIRE ALARM NOTIFICATION APPLIANCE

STROBES AND SPEAKERS LOCATED WITHIN THE

SMOKE ZONE UNDER ALARM SHALL BE

ACTIVATED. A CODED AUDIO MESSAGE SHALL BE

DISTRIBUTED TO THE FIRE ALARM SPEAKERS IN

ALL OTHER SMOKE ZONES IN THE HOSPITAL,

CLINIC AND CUP, THE STROBES LOCATED

OUTSIDE OF THE SMOKE ZONE UNDER ALARM

SHALL NOT BE ACTIVATED. THE CODED MESSAGE

SHALL BE AS DIRECTED BY THE CONTRACTING

OFFICER AND POST FIRE CHIEF.

CUP: THE CUP PORTION OF THE FACILITY

SHALL USE A GENERAL ALARM EVACUATION

SCHEME. UPON ACTIVATION OF THE SYSTEM

INPUTS AS INDICATED ON THIS MATRIX, ALL OF

THE FIRE ALARM NOTIFICATION APPLIANCE

STROBES AND SPEAKERS SHALL BE ACTIVATED

THROUGHOUT THE ENTIRE CUP. THE VOICE

ALARM MESSAGE IN THE CUP SHALL EVACUATE

THE ENTIRE CUP. A CODED AUDIO MESSAGE

SHALL BE DISTRIBUTED TO THE FIRE ALARM

SPEAKERS IN THE HOSPITAL AND CLINIC, THE

STROBES LOCATED OUTSIDE OF THE CUP

SHALL NOT BE ACTIVATED. THE CODED MESSAGE

SHALL BE AS DIRECTED BY THECONTRACTING

OFFICER AND POST FIRE CHIEF.

C. REFER TO SHEET FA602 FOR ADDITIONAL

REQUIREMENTS.

D. ALARMS WITHIN THE CLINIC SHALL NOT ACTIVE

NOTIFICATION APPLIANCE STROBES/SPEAKERS

OR SHUT DOWN HVAC FANS IN THE HOSPITAL.

ALARMS WITHIN THE HOSPITAL SHALL NOT ACTIVE

NOTIFICATION APPLIANCE STROBES/SPEAKERS

OR SHUT DOWN HVAC FANS IN THE CLINIC.

E. THE SPEAKERS LOCATED IN THE STAIRWELLS

AND THE ELEVATOR CABS SHALL ONLY BE

ACTIVATED BY USING THE LIVE ANNOUNCEMENT

MICROPHONES. THESE SPEAKERS SHALL NOT BE

ACTIVATED AUTOMATICALLY.

SY

M

D E S

C R

IP

TI

O N

D

FIRE ALARM SYSTEM

SEQUENCE OF OPERATION MATRIX

SYSTEM INPUTS

SY

ST

EM

O

UT

PU

TS

MA

NU

AL

P

UL

L S

TA

TI

ON

W

AT

ER

F

LO

W

S W

IT

CH

SP

RI

NK

LE

R

VA

LV

E

TA

MP

ER

S

W

IT

CH

W

AT

ER

F

LO

W

S W

IT

CH

EL

EV

AT

OR

MA

CH

IN

E

RO

OM

CO

MP

UT

ER

R

OO

M

DU

CT

M

OU

NT

ED

SM

OK

E

DE

TE

CT

OR

GR

OU

ND

F

AU

LT

CO

ND

UC

TO

R

BR

EA

K

EL

EV

AT

OR

M

AC

HI

NE

R

OO

M

SM

OK

E

DE

TE

CT

OR

EL

EV

AT

OR

LO

BB

Y

SM

OK

E

DE

TE

CT

OR

PR

IM

AR

Y

LE

VE

L

EL

EV

AT

OR

LO

BB

Y

SM

OK

E

DE

TE

CT

OR

AL

TE

RN

AT

E

LE

VE

L

AR

EA

S

MO

KE

D

ET

EC

TO

RS

SM

OK

E

DE

TE

CT

OR

A

T

HE

LD

O

PE

N

SM

OK

E

DO

OR

O

R

FI

RE

S

HU

TT

ER

DU

CT

M

OU

NT

ED

S

MO

KE

D

ET

EC

TO

R

AC

TI

VA

TI

ON

O

F

LO

CA

L O

PE

RA

TO

RS

CO

NS

OL

E

PR

E-

RE

CO

RD

ED

M

ES

SA

GE

(L

OC

MA

SS

N

OT

IF

IC

AT

IO

N

LIV

E

VO

IC

E

ME

SS

AG

E

(L

OC

EL

EV

AT

OR

S

HU

NT

T

RI

P

CO

IL

LO

SS

O F

PO

W

ER

PO

ST

IN

DI

CA

TI

NG

V

AL

VE

KI

TC

HE

N

HO

OD

S

UP

PE

SI

ON

S

YS

TE

M

DISCONNECT POWER AND FUEL SOURCE FROM

KITCHEN COOKING EQUIPMENT

MUTE PUBLIC ADDRESS SYSTEM SPEAKERS

SHUT-OFF POWER TO AUTOMATIC MOTORIZED

DOORS IN EGRESS PATH OF ASSOCIATED SMOKE

ZONE IN ALARM

ACTIVATE SELECTED MASS NOTIFICATION

PRE-RECORDED MESSAGE

TEMPORARILY OVERRIDE FIRE ALARM AUDIBLE

AND VISUAL SIGNALS AND DISPLAY A DISTINCT

SUPERVISORY SIGNAL AT THE FACP

ACTIVATE LIVE MASS NOTIFICATION VOICE

ANNOUNCEMENT

SHUT DOWN COMPUTER ROOM AIR

CONDITIONING UNIT 20

FI

RE

A

LA

RM

S

YS

TE

M

LIV

E

VO

IC

E

ME

SS

AG

E

AC

TI

VA

TI

ON

O

F

MA

SS

N

OT

IF

IC

AT

IO

N

SY

ST

EM

A

UT

ON

OM

OU

S

CO

NT

RO

L

UN

IT

P

RE

-R

EC

OR

DE

D

ME

SS

AG

E

CO

MP

UT

ER

R

OO

M

CL

EA

N

AG

EN

T

SY

ST

EM

C

OM

MO

N

TR

OU

BL

E

SM

OK

E

DE

TE

CT

OR

A

T

FI

RE

P

AR

TI

TI

ON

FI

RE

P

UM

P

RU

NN

IN

G

FI

RE

P

UM

P

LO

SS

O

F

PH

AS

E

FI

RE

P

UM

P

PH

AS

E

RE

VE

RS

AL

AC

TI

VA

TI

ON

O

F

MA

SS

N

OT

IF

IC

AT

IO

N

SY

ST

EM

A

UT

ON

OM

OU

S

CO

NT

RO

L

UN

IT

LI

VE

V

OI

CE

M

ES

SA

GE

FI

RE

P

UM

P

CO

NE

CT

ED

T

O

AL

TE

RN

AT

E

SO

UR

CE

A B C D E F G H I J K L M N O P Q R S T U V W X Y AA BB

ACTIVATE FIRE FIGHTERS SERVICE VISUAL

SIGNAL INTERMITTENTLY

ACTIVATE FIRE FIGHTERS SERVICE VISUAL

SIGNAL STEADY

CLOSE SMOKE/FIRE DAMPERS IN ASSOCIATED

SMOKE ZONE

CLOSE FIRE/SMOKE DAMPERS SERVING

COMPUTER ROOM

AC

TI

VA

TI

ON

O

F

TH

E

CO

MP

UT

ER

RO

OM

C

LE

AN

A

GE

NT

S

YS

TE

M

CC

31ACTIVATE AREA OF REFUGE BASE STATION IN

FACP/FMCP

AC

TI

VA

TI

ON

O

F

AR

EA

O

F

RE

FU

GE

TE

LE

PH

ON

E

ST

AT

IO

N

DD

SHEET NOTES:

NOTES:

Sheet Reference Number

AP

PR

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

1 :

FA605

FI

RE

A

LA

RM

M

AS

S

NO

TI

FI

CA

TI

ON

S

EQ

UE

NC

E

OF

O

PE

RA

TI

ON

RL

W

RL

W

KL

M

FA

SY

M

D E S

C R

IP

TI

O N

D

AT

E

A. THE HVAC SYSTEMS THE SURGERY AREA SHALL

BE SHUT DOWN ONLY BY SUPPLY DUCT

MOUNTED

SMOKE DETECTORS SERVING THE SURGERY

AREA.

B. CLINIC: THE CLINIC PORTION OF THE FACILITY

SHALL USE A GENERAL ALARM EVACUATION

SCHEME. UPON ACTIVATION OF THE SYSTEM

INPUTS AS INDICATED ON THIS MATRIX, ALL OF

THE FIRE ALARM NOTIFICATION APPLIANCE

STROBES AND SPEAKERS SHALL BE ACTIVATED

THROUGHOUT THE ENTIRE CLINIC. THE VOICE

ALARM MESSAGE IN THE CLINIC SHALL EVACUATE

THE ENTIRE CLINIC. A CODED AUDIO MESSAGE

SHALL BE DISTRIBUTED TO THE FIRE ALARM

SPEAKERS IN THE HOSPITAL AND CUP, THE

STROBES LOCATED OUTSIDE OF THE CLINIC

SMOKE ZONES SHALL NOT BE ACTIVATED. THE

CODED MESSAGE SHALL BE AS DIRECTED BY THE

CONTRACTING OFFICER AND POST FIRE CHIEF.

HOSPITAL: THE HOSPITAL PORTION OF THE

FACILITY SHALL USE A "DEFEND IN PLACE" TYPE

PARTIAL EVACUATION SCHEME FOR THE HOSPITAL

OCCUPANCY ONLY. UPON ACTIVATION OF THE

SYSTEM INPUTS AS INDICATED ON THIS MATRIX,

ONLY THE FIRE ALARM NOTIFICATION APPLIANCE

STROBES AND SPEAKERS LOCATED WITHIN THE

SMOKE ZONE UNDER ALARM SHALL BE

ACTIVATED. A CODED AUDIO MESSAGE SHALL BE

DISTRIBUTED TO THE FIRE ALARM SPEAKERS IN

ALL OTHER SMOKE ZONES IN THE HOSPITAL,

CLINIC AND CUP, THE STROBES LOCATED

OUTSIDE OF THE SMOKE ZONE UNDER ALARM

SHALL NOT BE ACTIVATED. THE CODED MESSAGE

SHALL BE AS DIRECTED BY THE CONTRACTING

OFFICER AND POST FIRE CHIEF.

CUP: THE CUP PORTION OF THE FACILITY

SHALL USE A GENERAL ALARM EVACUATION

SCHEME. UPON ACTIVATION OF THE SYSTEM

INPUTS AS INDICATED ON THIS MATRIX, ALL OF

THE FIRE ALARM NOTIFICATION APPLIANCE

STROBES AND SPEAKERS SHALL BE ACTIVATED

THROUGHOUT THE ENTIRE CUP. THE VOICE

ALARM MESSAGE IN THE CUP SHALL EVACUATE

THE ENTIRE CUP. A CODED AUDIO MESSAGE

SHALL BE DISTRIBUTED TO THE FIRE ALARM

SPEAKERS IN THE HOSPITAL AND CLINIC, THE

STROBES LOCATED OUTSIDE OF THE CUP

SHALL NOT BE ACTIVATED. THE CODED MESSAGE

SHALL BE AS DIRECTED BY THECONTRACTING

OFFICER AND POST FIRE CHIEF.

C. REFER TO SHEET FA602 FOR ADDITIONAL

REQUIREMENTS.

D. ALARMS WITHIN THE CLINIC SHALL NOT ACTIVE

NOTIFICATION APPLIANCE STROBES/SPEAKERS

OR SHUT DOWN HVAC FANS IN THE HOSPITAL.

ALARMS WITHIN THE HOSPITAL SHALL NOT ACTIVE

NOTIFICATION APPLIANCE STROBES/SPEAKERS

OR SHUT DOWN HVAC FANS IN THE CLINIC.

E. THE SPEAKERS LOCATED IN THE STAIRWELLS

AND THE ELEVATOR CABS SHALL ONLY BE

ACTIVATED BY USING THE LIVE ANNOUNCEMENT

MICROPHONES. THESE SPEAKERS SHALL NOT BE

ACTIVATED AUTOMATICALLY.

B

B

B

B

B

B

B

B B B B B B B B B B B

B B B B B B B B B B B

B B B B

A A

A A

A A

A

A A A A A A A

A A A A A A A

A

A

A

A

A

A

AA AAA A A A A

A

A

A

A

A

A

B B

B B

DN

DN

DN1

DN1

DN1

DN2

DN2

GL

GL

GL GL

GL

GL

GL

GL

1 2

3 4 5.6

5.9

7 8 9 10

A.3

Z

B

C

D

E.1

E.3

E.9

F.4

GL

20'-0" MAXIMUM. TYPICAL

FOR ALL PERIMETER STRIKE

TERMINATION DEVICES

B

B

B

B

B

B

B

B

B B

B B B B

B

B

B

B

B

B

B

B B B B

B B

B

B

B

GL

GL

GL

GL

GL

GL GL

DN5

DN5

GL

GL

GL

GL

DN

2 2

GLDN5

DN5

DN1

DN2

DN1

DN2

DN1

ELEVATION: 67'-2"

ELEVATION: 48'-0"

ELEVATION: 35'-0"

DN

DN1

DN5

DN1

DN1

3 4

DN1

A. PROVIDE BONDING CONNECTION TO ALL ROOF

DRAINS AND VENT PIPES.

B. USE EXOTHERMIC WELD CONNECTIONS FOR

ALL CONNECTIONS BELOW GRADE.

C. ALL LIGHTNING PROTECTION COMPONENTS

SHALL BE CLASS I, UNLESS OTHERWISE NOTED.

D. PROVIDE BONDING CONNECTION TO ALL METAL

BODIES LOCATED ON ROOF, INCLUDING

METALLIC LADDERS.

E. REFER TO SPECIFICATIONS SECTION

264101.0010 FOR ADDITIONAL REQUIREMENTS.

SHEET NOTES:

NOTES:

N

50'0 10' 30'

1/16"=1'-0" GRAPHIC SCALE

10'

KEY PLAN

A

B

P

HOSPITALCLINIC

H

V

KEY NOTES 00

Sheet Reference Number

AP

PR

C O

R

PS

O F

EN

G

IN

EE

R S

D

EP

AR

TM

EN

T

O F

TH

E

AR

M

Y

SA

C

R

AM

EN

TO

, C

AL

IF

O

R N

IA

FO

R

T

IR

W

IN

C

AL

IF

O

R N

IA

D es ig ne d by

D ra w n by

D es ig n fil e no

D at e:

R ev ie w ed b y:

S ub m itt ed b y:

Fi le n am e:

S pe c N o:

D ra w in g C od e:

P lo t d at e:

D w g sc al e:

R ev

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

FO

R

T

IR

W

IN

H O

S P

IT

AL

R

EP

L A

C

EM

EN

T

4 3 2 1

C

B

A

SHEET OF 1985

Sacramento District

8-

- 0

D

EC

EM

BE

R, RO

N

W . L

OW

RY

I52 1-

As in dic ate d

H-EQ15A

LIG

HT

NI

NG

P

RO

TE

CT

IO

N

PL

AN

HO

SP

IT

AL

Au tho r

De sig ne r

Ch ec ke r

H-

EQ

A

1 REFER TO SHEET H-EQ15B FOR CONTINUATION.

2 TO AMBULANCE SHELTER. REFER TO 3/EQ401

FOR CONTINUATION.

3 ROUTE DOWN CONDUCTOR DOWN TO GRADE,

IN 1" PVC CONDUIT, CONCEALED INSIDE STEEL

TUBE SUPPORT.

4 MOUNT AIR TERMINAL TO TOP OF TRELLIS

BEAM. SECURE TERMINAL BASE IN PLACE WITH

AN APPLICATION OF ADHESIVE COMPOUND

THAT IS COMPATIBLE WITH TRELLIS.

SY

M

D E S

C R

IP

TI

O N

D

600 VOLUME 6 COVER
602 EG001-003
EG001 - ELECTRICAL SYMBOLS LEGEND AND ABBREVIATIONS
EG002 - ELECTRICAL SYMBOLS LEGEND
EG003 - ELECTRICAL SYMBOLS LEGEND
604 EG004-006
EG004 - TELECOMMUNICATIONS SYMBOL LEGEND
EG005 - TELECOMMUNICATIONS SYMBOL LEGEND
EG006 - FIRE ALARM SYMBOL LEGEND
606 ES100
608 ED100s
ED101 - ELECTRICAL SITE UTILITY KEY PLAN - DEMOLITION
ED102 - ELECTRICAL SITE UTILITY KEY PLAN - DEMOLITION
610 ES101-120
ES100 - ELECTRICAL SITE UTILITY KEY PLAN
ES101 - ELECTRICAL SITE UTILITY PLAN
ES102 - ELECTRICAL SITE UTILITY PLAN
ES103 - ELECTRICAL SITE UTILITY PLAN
ES104 - ELECTRICAL SITE UTILITY PLAN
ES105 - ELECTRICAL SITE UTILITY PLAN
ES106 - ELECTRICAL SITE UTILITY PLAN
ES107 - ELECTRICAL SITE UTILITY PLAN
ES108 - ELECTRICAL SITE UTILITY PLAN
ES109 - ELECTRICAL SITE UTILITY PLAN
ES110 - ELECTRICAL SITE UTILITY PLAN
ES111 - ELECTRICAL SITE UTILITY PLAN
ES112 - ELECTRICAL SITE UTILITY PLAN
ES113 - ELECTRICAL SITE UTILITY PLAN
ES114 - ELECTRICAL SITE UTILITY PLAN
ES115 - ELECTRICAL SITE UTILITY PLAN
ES116 - ELECTRICAL SITE UTILITY PLAN
ES117 - ELECTRICAL SITE UTILITY PLAN
ES118 - ELECTRICAL SITE UTILITY PLAN
ES119 - ELECTRICAL SITE UTILITY PLAN
ES120 - ELECTRICAL SITE UTILITY PLAN
612 ES121-138
ES121 - ELECTRICAL SITE UTILITY PLAN
ES122 - ELECTRICAL SITE UTILITY PLAN
ES123 - ELECTRICAL SITE UTILITY PLAN
ES124 - ELECTRICAL SITE UTILITY PLAN
ES125 - ELECTRICAL SITE UTILITY PLAN
ES126 - ELECTRICAL SITE UTILITY PLAN
ES127 - ELECTRICAL SITE UTILITY PLAN
ES128 - ELECTRICAL SITE UTILITY PLAN
ES129 - ELECTRICAL SITE UTILITY PLAN
ES130 - ELECTRICAL SITE UTILITY PLAN
ES131 - ELECTRICAL SITE UTILITY PLAN
ES132 - ELECTRICAL SITE UTILITY PLAN
ES133 - ELECTRICAL SITE UTILITY PLAN
ES134 - ELECTRICAL SITE UTILITY PLAN
ES135 - ELECTRICAL SITE UTILITY PLAN
ES136 - ELECTRICAL SITE UTILITY PLAN
ES137 - ELECTRICAL SITE UTILITY PLAN
ES138 - ELECTRICAL SITE UTILITY PLAN
614 ES200s
ES201 - OVERALL SOLAR ARRAY KEYPLAN
ES202 - SOLAR ARRAY PLAN
ES203 - SOLAR ARRAY PLAN
616 ES300s
ES300 - SITE LIGHTING KEY PLAN
ES301 - SITE LIGHTING
ES302 - SITE LIGHTING
ES303 - SITE LIGHTING
ES304 - SITE LIGHTING
ES305 - SITE LIGHTING
ES306 - SITE LIGHTING
ES307 - SITE LIGHTING
ES308 - SITE LIGHTING
ES309 - SITE LIGHTING
ES310 - SITE LIGHTING
ES311 - SITE LIGHTING
ES312 - SITE LIGHTING
618 ES400s
ES401 - ENLARGED ADN BUILDING PLAN
ES404 - ENLARGED PREPACKAGED INVERTER BUILDINGS
ES405 - ENLARGED PLANS
ES406 - ENLARGED PLANS
ES407 - ENLARGED PLANS
620 ES500s
ES501 - SITE DETAILS
ES502 - SITE DETAILS
ES503 - SITE DETAILS
ES504 - SITE DETAILS
ES505 - SITE DETAILS
ES506 - SITE DETAILS
ES507 - SITE DETAILS
ES508 - SITE DETAILS
ES509 - SITE DETAILS
ES510 - SITE DETAILS
ES511 - SITE DETAILS
ES512 - SITE DETAILS
622 ES800s
ES801 - SITE UTILITY SCHEDULES
ES802 - SITE UTILITY SCHEDULES
ES803 - SITE UTILITY SCHEDULES
ES804 - SITE UTILITY SCHEDULES
ES805 - SITE UTILITY SCHEDULES
ES806 - SITE UTILITY SCHEDULES
624 H-EL100s-400s
H-EL111 - LEVEL 1, ZONE 1, FLOOR PLAN - LIGHTING
H-EL112 - LEVEL 1, ZONE 2, FLOOR PLAN - LIGHTING
H-EL113 - LEVEL 1, ZONE 3, FLOOR PLAN - LIGHTING
H-EL114 - LEVEL 1, ZONE 4, FLOOR PLAN - LIGHTING
H-EL115 - LEVEL 1, ZONE 5, FLOOR PLAN – LIGHTING
H-EL121 - LEVEL 2, ZONE 1, FLOOR PLAN - LIGHTING
H-EL122 - LEVEL 2, ZONE 2, FLOOR PLAN - LIGHTING
H-EL123 - LEVEL 2, ZONE 3, FLOOR PLAN - LIGHTING
H-EL124 - LEVEL 2, ZONE 4, FLOOR PLAN - LIGHTING
H-EL125 - LEVEL 2, ZONE 5, FLOOR PLAN – LIGHTING
H-EL131 - LEVEL 3, ZONE 1, FLOOR PLAN - LIGHTING
H-EL132 - LEVEL 3, ZONE 2, FLOOR PLAN - LIGHTING
H-EL133 - LEVEL 3, ZONE 3, FLOOR PLAN - LIGHTING
H-EL134 - LEVEL 3, ZONE 4, FLOOR PLAN - LIGHTING
H-EL135 - LEVEL 3, ZONE 5, FLOOR PLAN – LIGHTING
H-EL141 - LEVEL 4, ZONE 1, FLOOR PLAN - LIGHTING
H-EL142 - LEVEL 4, ZONE 2, FLOOR PLAN - LIGHTING
H-EL144 - LEVEL 4, ZONE 4, FLOOR PLAN - LIGHTING
H-EL301 - LIGHTING SECTION PLANS
H-EL302 - LIGHTING SECTION PLANS
H-EL303 - LIGHTING SECTION PLANS
H-EL401 - LIGHTING ENLARGED PLANS
H-EL402 - LIGHTING ENLARGED PLANS
H-EL403 - LIGHTING ENLARGED PLANS
H-EL404 - LIGHTING ENLARGED PLANS
626 EL500s-800s
EL501 - LIGHTING FIXTURE DETAILS
EL502 - LIGHTING FIXTURE DETAILS
EL503 - LIGHTING FIXTURE DETAILS
EL504 - LIGHTING FIXTURE DETAILS
EL505 - LIGHTING FIXTURE DETAILS
EL506 - LIGHTING FIXTURE DETAILS
EL507 - LIGHTING FIXTURE DETAILS
EL508 - LIGHTING FIXTURE DETAILS
EL509 - LIGHTING FIXTURE DETAILS
EL510 - LIGHTING FIXTURE DETAILS
EL511 - LIGHTING FIXTURE DETAILS
EL512 - LIGHTING FIXTURE DETAILS
EL601 - LIGHTING CONTROL DETAILS
EL602 - LIGHTING CONTROL DETAILS
EL603 - LIGHTING CONTROL DETAILS
EL604 - LIGHTING CONTROL DETAILS
EL605 - LIGHTING CONTROL DETAILS
EL606 - LIGHTING CONTROL DETAILS
EL607 - LIGHTING CONTROL DETAILS
EL701 - LIGHTING FIXTURE SCHEDULE
EL702 - LIGHTING FIXTURE SCHEDULE
EL703 - SITE LIGHTING FIXTURE SCHEDULE
EL801 - RELAY PANEL SCHEDULES
EL802 - RELAY PANEL SCHEDULES
628 H-EP100s-400s
H-EP111 - LEVEL 1, ZONE 1, FLOOR PLAN - POWER
H-EP112 - LEVEL 1, ZONE 2, FLOOR PLAN - POWER
H-EP113 - LEVEL 1, ZONE 3, FLOOR PLAN - POWER
H-EP114 - LEVEL 1, ZONE 4, FLOOR PLAN - POWER
H-EP115 - LEVEL 1, ZONE 5, FLOOR PLAN - POWER
H-EP121 - LEVEL 2, ZONE 1, FLOOR PLAN - POWER
H-EP122 - LEVEL 2, ZONE 2, FLOOR PLAN - POWER
H-EP123 - LEVEL 2, ZONE 3, FLOOR PLAN - POWER
H-EP124 - LEVEL 2, ZONE 4, FLOOR PLAN - POWER
H-EP125 - LEVEL 2, ZONE 5, FLOOR PLAN - POWER
H-EP131 - LEVEL 3, ZONE 1, FLOOR PLAN - POWER
H-EP132 - LEVEL 3, ZONE 2, FLOOR PLAN - POWER
H-EP133 - LEVEL 3, ZONE 3, FLOOR PLAN - POWER
H-EP134 - LEVEL 3, ZONE 4, FLOOR PLAN - POWER
H-EP135 - LEVEL 3, ZONE 5, FLOOR PLAN - POWER
H-EP141 - LEVEL 4, ZONE 1, FLOOR PLAN - POWER
H-EP142 - LEVEL 4, ZONE 2, FLOOR PLAN - POWER
H-EP143 - LEVEL 4, ZONE 3, FLOOR PLAN - POWER
H-EP144 - LEVEL 4, ZONE 4, FLOOR PLAN - POWER
H-EP401 - ENLARGED FLOOR PLANS
H-EP402 - ENLARGED FLOOR PLANS
H-EP403 - ENLARGED FLOOR PLANS
H-EP404 - ENLARGED FLOOR PLANS
H-EP405 - ENLARGED FLOOR PLANS
H-EP406 - ENLARGED FLOOR PLANS
H-EP407 - ENLARGED FLOOR PLANS
H-EP408 - ENLARGED FLOOR PLANS
H-EP409 - ENLARGED ELEVATOR MACHINE ROOM POWER PLANS
H-EP410 - ENLARGED OPERATING ROOM POWER PLANS
H-EP411 - ENLARGED PLANS - SURGICAL EQUIPMENT LAYOUT
H-EP412 - ELEVATIONS AND CIRCUITING SCHEDULES - SURGICAL BOOMS
H-EP413 - ENLARGED LABORATORY POWER PLANS
H-EP414 - ENLARGED UPS AND DATA ROOM POWER PLANS
H-EP415 - ENLARGED NORTH KITCHEN-SERVERY SUITE POWER PLAN
H-EP416 - ENLARGED SOUTH KITCHEN-SERVERY SUITE POWER PLAN
H-EP417 - ENLARGED X-RAY ROOM POWER PLANS
H-EP418 - ENLARGED TYPICAL PATIENT ROOM POWER PLANS
H-EP419 - HEADWALL RECEPTACLE CIRCUITING SCHEDULES
H-EP420 - ENLARGED EYELANE ROOM POWER PLANS
H-EP421 - CT SCAN EQUIPMENT DRAWINGS
H-EP422 - CT SCAN EQUIPMENT DRAWINGS
H-EP423 - CT SCAN EQUIPMENT DRAWINGS
H-EP424 - CT SCAN EQUIPMENT DRAWINGS
630 EP500s-800s
EP501 - ELECTRICAL DETAILS
EP502 - ELECTRICAL DETAILS
EP503 - ELECTRICAL DETAILS
EP504 - SWITCHGEAR ELEVATIONS - CUP
EP505 - SWITCHGEAR ELEVATIONS - HOSPITAL
EP506 - SWITCHBOARD ELEVATIONS - CLINIC
EP507 - ATS TERMINAL CABINET DETAILS
EP508 - AUTOMATIC TRANSFER SWITCH WIRING DIAGRAM
EP509 - CENTRAL UTILITY PLANT ELECTRICAL DETAILS
EP510 - GENERATOR REMOTE ANNUNCIATOR PANEL
EP511 - GENERATOR FUEL - OIL TRANSFER PUMP CONTROL ROOM
EP512 - GENERATOR ELEVATION DETAIL
EP513 - POWER MONITORING SYSTEM RISER DIAGRAM
EP514 - POWER MONITORING SYSTEM RISER DIAGRAM
EP515 - SWITCHBOARD ELEVATIONS
EP516 - MISCELLANEOUS CONNECTION DIAGRAMS
EP517 - ELECTRICAL DETAILS
EP518 - ELECTRICAL DETAILS
EP601 - SINGLE LINE DIAGRAMS - UTILITY SERVICE
EP602 - SINGLE LINE DIAGRAMS - CUP NORMAL POWER
EP603 - SINGLE LINE DIAGRAMS - CUP ESSENTIAL POWER
EP604 - SINGLE LINE DIAGRAMS - CUP ESSENTIAL POWER
EP605 - SINGLE LINE DIAGRAMS - HOSPITAL NORMAL POWER
EP606 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER
EP607 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER
EP608 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER
EP609 - SINGLE LINE DIAGRAMS - HOSPITAL ESSENTIAL POWER
EP610 - SINGLE LINE DIAGRAMS - CLINIC NORMAL POWER
EP611 - SINGLE LINE DIAGRAMS - CLINIC NORMAL POWER
EP612 - SINGLE LINE DIAGRAMS - CLINIC NORMAL POWER
EP613 - SINGLE LINE DIAGRAMS - CLINIC ESSENTIAL POWER
EP614 - SINGLE LINE DIAGRAMS - CLINIC ESSENTIAL POWER
EP615 - SINGLE LINE DIAGRAMS - PHOTOVOLTAICS
EP616 - SINGLE LINE DIAGRAMS - PHOTOVOLTAICS
EP617 - SINGLE LINE DIAGRAM - PHOTOVOLTAICS
EP618 - HOSPITAL ELECTRICAL GROUND BUS CONNECTION RISER
EP619 - OVERALL GROUNDING DIAGRAM
EP701 - ELECTRICAL SCHEDULES
EP702 - ELECTRICAL SCHEDULES
EP703 - ELECTRICAL SCHEDULES
EP704 - ELECTRICAL SCHEDULES
EP705 - ELECTRICAL SCHEDULES
EP706 - ELECTRICAL SCHEDULES
EP707 - ELECTRICAL SCHEDULES
EP800 - ELECTRICAL PANEL SCHEDULES
EP801 - ELECTRICAL PANEL SCHEDULES
EP802 - ELECTRICAL PANEL SCHEDULES
EP803 - ELECTRICAL PANEL SCHEDULES
EP804 - ELECTRICAL PANEL SCHEDULES
EP805 - ELECTRICAL PANEL SCHEDULES
EP806 - ELECTRICAL PANEL SCHEDULES
EP807 - ELECTRICAL PANEL SCHEDULES
EP808 - ELECTRICAL PANEL SCHEDULES
EP809 - ELECTRICAL PANEL SCHEDULES
EP810 - ELECTRICAL PANEL SCHEDULES
EP811 - ELECTRICAL PANEL SCHEDULES
EP812 - ELECTRICAL PANEL SCHEDULES
EP813 - ELECTRICAL PANEL SCHEDULES
EP814 - ELECTRICAL PANEL SCHEDULES
EP815 - ELECTRICAL PANEL SCHEDULES
EP816 - ELECTRICAL PANEL SCHEDULES
EP817 - ELECTRICAL PANEL SCHEDULES
EP818 - ELECTRICAL PANEL SCHEDULES
EP819 - ELECTRICAL PANEL SCHEDULES
EP820 - ELECTRICAL PANEL SCHEDULES
EP821 - ELECTRICAL PANEL SCHEDULES
EP822 - ELECTRICAL PANEL SCHEDULES
EP823 - ELECTRICAL PANEL SCHEDULES
EP824 - ELECTRICAL PANEL SCHEDULES
EP825 - ELECTRICAL PANEL SCHEDULES
EP826 - ELECTRICAL PANEL SCHEDULES
EP827 - ELECTRICAL PANEL SCHEDULES
EP828 - ELECTRICAL PANEL SCHEDULES
EP829 - ELECTRICAL PANEL SCHEDULES
EP830 - ELECTRICAL PANEL SCHEDULES
EP831 - ELECTRICAL PANEL SCHEDULES
EP832 - ELECTRICAL PANEL SCHEDULES
EP833 - ELECTRICAL PANEL SCHEDULES
EP834 - ELECTRICAL PANEL SCHEDULES
EP835 - ELECTRICAL PANEL SCHEDULES
EP836 - ELECTRICAL PANEL SCHEDULES
EP837 - ELECTRICAL PANEL SCHEDULES
EP838 - ELECTRICAL PANEL SCHEDULES
EP839 - ELECTRICAL PANEL SCHEDULES
EP840 - ELECTRICAL PANEL SCHEDULES
EP841 - ELECTRICAL PANEL SCHEDULES
EP842 - ELECTRICAL PANEL SCHEDULES
EP843 - ELECTRICAL PANEL SCHEDULES
EP844 - ELECTRICAL PANEL SCHEDULES
EP845 - ELECTRICAL PANEL SCHEDULES
632 H-ET100s
H-ET110 - LEVEL 1 PUBLIC ADDRESS ZONE PLANS
H-ET110A - LEVEL 1, AREA A - COMMUNICATION ZONE ALLOCATION FLOOR PLAN
H-ET110B - LEVEL 1 , AREA B - COMMUNICATION ZONE ALLOCATION FLOOR PLAN
H-ET111 - LEVEL 1, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS
H-ET112 - LEVEL 1, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS
H-ET113 - LEVEL 1, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS
H-ET114 - LEVEL 1, ZONE 4, FLOOR PLAN - TELECOMMUNICATIONS
H-ET115 - LEVEL 1, ZONE 5, FLOOR PLAN - TELECOMMUNICATIONS
H-ET120 - LEVEL 2 PUBLIC ADDRESS ZONE PLANS
H-ET120A - LEVEL 2, AREA A - COMMUNICATION ZONE ALLOCATION FLOOR PLAN
H-ET120B - LEVEL 2 , AREA B - COMMUNICATION ZONE ALLOCATION FLOOR PLAN
H-ET121 - LEVEL 2, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS
H-ET122 - LEVEL 2, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS
H-ET123 - LEVEL 2, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS
H-ET124 - LEVEL 2, ZONE 4, FLOOR PLAN - TELECOMMUNICATIONS
H-ET125 - LEVEL 2, ZONE 5, FLOOR PLAN – TELECOMMUNICATIONS
H-ET130 - LEVEL 3 PUBLIC ADDRESS ZONE PLANS
H-ET130A - LEVEL 3 , AREA A - COMMUNICATION ZONE ALLOCATION FLOOR PLAN
H-ET130B - LEVEL 3 , AREA B - COMMUNICATION ZONE ALLOCATION FLOOR PLAN
H-ET131 - LEVEL 3, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS
H-ET132 - LEVEL 3, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS
H-ET133 - LEVEL 3, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS
H-ET134 - LEVEL 3, ZONE 4, FLOOR PLAN – TELECOMMUNICATIONS
H-ET135 - LEVEL 3, ZONE 5, FLOOR PLAN – TELECOMMUNICATIONS
H-ET141 - LEVEL 4, ZONE 1, FLOOR PLAN - TELECOMMUNICATIONS
H-ET142 - LEVEL 4, ZONE 2, FLOOR PLAN - TELECOMMUNICATIONS
H-ET143 - LEVEL 4, ZONE 3, FLOOR PLAN - TELECOMMUNICATIONS
H-ET144 - LEVEL 4, ZONE 4, FLOOR PLAN – TELECOMMUNICATIONS
634 H-ET400s
H-ET401 - ENLARGED FLOOR PLANS
H-ET402 - ENLARGED FLOOR PLANS
H-ET403 - ENLARGED FLOOR PLANS
H-ET404 - ENLARGED FLOOR PLANS
H-ET405 - ENLARGED FLOOR PLANS
H-ET406 - ENLARGED FLOOR PLANS
H-ET407 - ENLARGED FLOOR PLANS
H-ET408 - ENLARGED FLOOR PLANS
H-ET409 - ENLARGED FLOOR PLANS
H-ET410 - ENLARGED FLOOR PLANS
H-ET411 - ENLARGED FLOOR PLANS
H-ET412 - ENLARGED FLOOR PLANS
H-ET413 - ENLARGED FLOOR PLANS
H-ET414 - ENLARGED FLOOR PLANS
H-ET415 - ENLARGED FLOOR PLANS
H-ET416 - ENLARGED FLOOR PLANS
H-ET417 - ENLARGED FLOOR PLANS
H-ET418 - ENLARGED FLOOR PLANS
H-ET419 - ENLARGED FLOOR PLANS
H-EY111 - LEVEL 1, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
636 ET500s-800s
ET501 - TELECOMMUNICATIONS DETAILS
ET502 - TELECOMMUNICATIONS DETAILS
ET503 - TELECOMMUNICATIONS DETAILS
ET504 - TELECOMMUNICATIONS DETAILS
ET505 - TELECOMMUNICATIONS DETAILS
ET506 - TELECOMMUNICATIONS DETAILS
ET601 - OUTSIDE PLANT CABLE ENTRANCE RISER DIAGRAM - ADN
ET602 - OUTSIDE PLANT CABLE ENTRANCE RISER DIAGRAM - HOSPITAL
ET603 - VOICE AND DATA BACKBONE RISER DIAGRAM - HOSPITAL
ET604 - VOICE AND DATA BACKBONE RISER DIAGRAM - CLINIC
ET605 - VOICE AND DATA HORIZONTAL CONNECTION DIAGRAM
ET606 - TELECOMMUNICATIONS RISER DIAGRAMS
ET607 - TELECOMMUNICATIONS GROUNDING DIAGRAM
ET608 - TELEVISION RISER DIAGRAM
ET609 - PUBLIC ADDRESS RISER DIAGRAM
ET610 - PUBLIC ADDRESS SYSTEM RISER DIAGRAM
ET801 - HOSPITAL NURSE CALL SCHEDULES
ET802 - HOSPITAL NURSE CALL SCHEDULES
ET803 - HOSPITAL NURSE CALL SCHEDULES
ET804 - CLINIC NURSE CALL SCHEDULES
ET805 - CLINIC NURSE CALL SCHEDULES
638 H-EY100s
H-EY111 - LEVEL 1, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY112 - LEVEL 1, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY113 - LEVEL 1, ZONE 3, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY114 - LEVEL 1, ZONE 4, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY115 - LEVEL 1, ZONE 5, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY121 - LEVEL 2, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY122 - LEVEL 2, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY123 - LEVEL 2, ZONE 3, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY124 - LEVEL 2, ZONE 4, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY125 - LEVEL 2, ZONE 5, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY131 - LEVEL 3, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY132 - LEVEL 3, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY133 - LEVEL 3, ZONE 3, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY134 - LEVEL 3, ZONE 4, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY135 - LEVEL 3, ZONE 5, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY141 - LEVEL 4, ZONE 1, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY142 - LEVEL 4, ZONE 2, FLOOR PLAN - ELECTRONIC SECURITY SYSTEM
H-EY143 - LEVEL4, ZONE 3 FLOOR PLAN - ELECTRONIC SECURITY SYSTEMS
H-EY144 - LEVEL4, ZONE 4 FLOOR PLAN - ELECTRONIC SECURITY SYSTEMS
640 EY500s-800s
EY501 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY502 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY503 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY504 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY505 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY506 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY507 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY508 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY509 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY510 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY511 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY512 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY513 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY514 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY515 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY516 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY517 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY518 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY519 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY520 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY521 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY522 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY523 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY524 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY525 - ELECTRONIC SECURITY DOOR CONTROL DETAILS
EY601 - ELECTRONIC SECURITY DETAILS
EY602 - ELECTRONIC SECURITY DETAILS
EY701 - ELECTRONIC SECURITY SYSTEM NETWORK RISER DIAGRAM
EY702 - ELECTRONIC SECURITY SYSTEM NETWORK RISER DIAGRAM
EY703 - ELECTRONIC SECURITY SYSTEM TYPICAL CONNECTION DIAGRAMS
EY801 - ELECTRONIC SECURITY SCHEDULES
EY802 - ELECTRONIC SECURITY SCHEDULES
EY803 - ELECTRONIC SECURITY SCHEDULES
642 H-FA100s
H-FA111 - LEVEL 1, ZONE 1, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA112 - LEVEL 1, ZONE 2, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA113 - LEVEL 1, ZONE 3, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA114 - LEVEL 1, ZONE 4, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA115 - LEVEL 1, ZONE 5, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA121 - LEVEL 2, ZONE 1, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA122 - LEVEL 2, ZONE 2, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA123 - LEVEL 2, ZONE 3, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA124 - LEVEL 2, ZONE 4, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA125 - LEVEL 2, ZONE 5, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION
H-FA131 - LEVEL 3, ZONE 1, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA132 - LEVEL 3, ZONE 2, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA133 - LEVEL 3, ZONE 3, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA134 - LEVEL 3, ZONE 4, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION
H-FA135 - LEVEL 3, ZONE 5, FLOOR PLAN - FIRE ALARM-MASS NOTIFICATION
H-FA141 - LEVEL 4, ZONE 1, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION
H-FA142 - LEVEL 4, ZONE 2, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION
H-FA143 - LEVEL 4, ZONE 3, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION
H-FA144 - LEVEL 4, ZONE 4, FLOOR PLAN – FIRE ALARM-MASS NOTIFICATION
644 FA600s
FA601 - TYPICAL FIRE ALARM CONNECTION DIAGRAM
FA602 - TYPICAL FIRE ALARM DEVICE CONNECTION DIAGRAM
FA603 - TYPICAL FIRE ALARM CONNECTION DIAGRAM
FA604 - FIRE ALARM MASS NOTIFICATION SEQUENCE OF OPERATION
FA605 - FIRE ALARM MASS NOTIFICATION SEQUENCE OF OPERATION
646 H-EQ100s
H-EQ15A - LIGHTNING PROTECTION PLAN - HOSPITAL
H-EQ15B - LIGHTNING PROTECTION PLAN - CLINIC
648 EQ400s-500s
EQ401 - LIGHTNING PROTECTION ENLARGED PLANS
EQ501 - LIGHTNING PROTECTION DETAILS
EQ502 - LIGHTNING PROTECTION DETAILS
EQ503 - LIGHTNING PROTECTION DETAILS