About this file

This document contains an architectural door schedule and details for a construction project. The Puerto Rico Army National Guard requires construction of an Engineering Housing and Maintenance Shop at Camp Santiago Joint Training Center in Salinas, Puerto Rico. The project involves general construction work including installation of various rated and non-rated doors. The door schedule specifies one hundred forty-two door locations with corresponding details for type, size, materials, fire rating, glazing and hardware. Door materials include aluminum, hollow metal, steel and wood. Glazing types include clear, tempered and insulated glass. The project also includes overhead coiling doors, storefront entrances and Dutch doors. Referenced drawings provide additional framing and opening details.

This opportunity is solicited under solicitation number W912LR24B0001 for military construction of the required facility. The contractor will provide all labor, materials, tools and equipment to complete the general construction work as detailed in the statement of work. The awarding agency is the Department of the Army National Guard.

View the file

Other files

File Type Posted
OF1419 - Abstract of Offers.pdf PDF
W912LR24B0001 DPW MILCON BID TABULATION-Final.pdf PDF
W912LR24B0001 - Ammendment 003 Modification Summary.pdf PDF
W912LR24B0001 - Ammendment 003 Conform Copy.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 10 56 29.26_Amendment 02_08-Mar-2024.pdf PDF
(Revised) Questions and Answers to RFIs.xlsx XLSX spreadsheet
PRARNG_EHMS_Camp Santiago_DWG A-551_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG Q-102_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 07 42 13.23_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 10 73 16.13_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG S-503_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG A-802_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 00 00 00-TOC_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG S-200_Amendment 02_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG A-572_Amendment 02_08-Mar-2024.pdf PDF
Questions and Answers to RFIs - W912LR-24-B-0001 .xlsx XLSX spreadsheet
PRARNG_EHMS_Camp Santiago_DWG S-200_Amendment 01_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 10 73 16.13_Amendment 01_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG A-630_Amendment 01_08-Mar-2024.pdf PDF
W912LR24B0001 - Ammendment 002 (Conform Copy).pdf PDF
PRARNG_EHMS_Camp Santiago_DWG A-802_Amendment 01_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG S-503_Amendment 01_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 07 42 13.23_Amendment 01_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG A-551_Amendment 01_08-Mar-2024.pdf PDF
Geotechnical Report.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 10 56 29.26_Amendment 01_08-Mar-2024.pdf PDF
Lead Based Paint Inspection Report DPW Buildings 38 56 57.pdf PDF
PRARNG_EHMS_Camp Santiago_SPEC 00 00 00-TOC_Amendment 01_08-Mar-2024.pdf PDF
LEAD-BASED PAINT INSPECTION REPORT BLDGs 50 54 55 58.pdf PDF
Asbesto Reports DPW Buildings.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG Q-102_Amendment 01_08-Mar-2024.pdf PDF
PRARNG_EHMS_Camp Santiago_DWG A-572_Amendment 01_08-Mar-2024.pdf PDF
W912LR24B0001 - Ammendment 002 (Modification Summary).pdf PDF
DPW - Pre Proposal Conference Minutes.pdf PDF
W912LR24B0001 - Ammendment 0001.pdf PDF
DPW Site Visit Attendance List 30JAN24.pdf PDF
Site Visit Project Description DPW.pptx PPTX presentation
Pre-Proposal Site Visit Slides - DPW 30JAN24 (003).pptx - Read-Only.pptx PPTX presentation
Attachment 02 - PRARNG EHMS Camp Santiago SPECS Vol 2 of 2 REV 19-July-2023.pdf PDF
Attachement 07 - Municipality of Salinas - Const Tax Exemption.pdf PDF
Attachment 05 - PRARNG Master Plan EA Final Feb 2021.pdf PDF
W912LR-24-B-0001 DPW Solicitation.pdf PDF
Attachement 06 - PRARNG EHMS Camp Santiago DRAWINGS Final 19 July 2023.pdf PDF
Attachment 01 - PRARNG EHMS Camp Santiago SPECS Vol 1 of 2 REV 19-July-2023.pdf PDF
Attachment 04 - PR-EA Master Plan FONSI Final Signed Feb 2021.pdf PDF
Attachment 03 - Environmental Considerations-PCL Legal Translate Final.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. DOOR DETAILS ARE ON DRAWING A-631 UNLESS OTHERWISE NOTED

2. ALL WOOD DOORS SHALL BE PREFINISHED - REFER TO SPECIFICATIONS

3. ALL STEEL DOORS AND FRAMES SHALL BE PAINTED

4. DO NOT PAINT LABELS OF TESTING AGENCY ON FIRE-RATED DOORS AND FRAMES

5. ALL EXTERIOR STEEL DOORS AND FRAMES SHALL BE GALVANIZED. SOME INTERIOR

DOORS AND FRAMES ARE GALVANIZED. REFER TO DOOR SCHEDULE. WIPE COAT

GALVANIZED STEEL IS NOT ACCEPTABLE.

6. ALL FIRE-RATED DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING

7. FIRE DOORS AND FRAMES SHALL HAVE AN APPROVED LABEL OR LISTING MARK

INDICATING THE FIRE-PROTECTION RATING, WHICH IS PRIMARILY AFFIXED AT THE

FACTORY WHERE FABRICATION AND ASSEMBLY ARE PERFORMED.

8. FIRE-RATED DOOR FRAMES SHALL BE INSTALLED STRICTLY PER MANUFACTURER'S

PRINTED INSTRUCTIONS. MANUFACTURER'S PRINTED INSTRUCTIONS SHALL BE MADE

AVAILABLE TO THE INSPECTION AUTHORITY.

9. ALL EXTERIOR DOORS SHALL BE INSULATED.

10. ALL EXIT DOOR HARDWARE SHALL ALLOW DOORS TO BE OPENED IN THE DIRECTION OF

EXIT WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.

11. THE MAXIMUM EXTERIOR DOOR OPENING EFFORTS SHALL NOT EXCEED 8.5 POUNDS.

12. BOTH THE LATCHING AND DEAD BOLT DEVICES ON EXTERIOR DOORS SHALL RELEASE

WITH A SINGLE ACTION OF THE INSIDE LEVER.

13. HINGES FOR OUT-SWINGING EXTERIOR DOORS SHALL BE EQUIPPED WITH NON-

REMOVABLE HINGE PINS IF NOT SCHEDULED TO RECEIVE CONTINUOUS HINGE.

14. REMOVABLE GLAZING STOPS AT BORROW LITES SHALL BE INSTALLED ON SECURE SIDE.

15. DO NOT CAULK BACK BEND STEEL DOOR FRAMES TO GYPSUM BOARD PARTITIONS.

16. THE DOOR FRAME MANUFACTURER SHALL VERIFY ACTUAL WALL / PARTITION THICKNESS

WITH CONTRACTOR PRIOR TO FABRICATION OF DOOR FRAMES.

17. REFER TO SPECIFICATIONS FOR HARDWARE GROUPS.

DOOR SCHEDULE GENERAL NOTES

1. GALVANIZED DOOR AND FRAME

2. INSULATED DOOR

3. UNDERCUT DOOR 3/4" COORDINATE BOTTOM/UNDERCUT OF DOORS WITH FINISH

MATERIALS, THRESHOLDS, ETC.

4. OVERHEAD COILING DOOR SIZE INDICATED IS FOR FINISHED OPENING. ACTUAL DOOR

SIZE WILL BE LARGER BASED ON MANUFACTURER'S STANDARDS.

5. EXISTING OVERHEAD DOOR RELOCATED FROM EXISTING CARPENTRY SHOP (X2),

PLUMBING SHOP, AND ELECTRICAL SHOP. PROTECT DURING DEMOLITION AND

CONSTRUCTION, STORE ON SITE UNTIL INSTALLED. VERIFY DIMENSIONS AND POWER

REQUIREMENTS IN THE FIELD PRIOR TO INSTALLATION.

6. NOT USED

7. PROVIDE COAT HOOK CENTERED ON BACK SIDE OF DOOR AT 5'-6" AFF

8. POWER ASSISTED ENTRANCE DOOR

DOOR SCHEDULE REMARKS

ALUM ALUMINUM

HM HOLLOW METAL

MFR HARDWARE BY DOOR

MANUFACTURER

STL STEEL

WD SOLID CORE WOOD

GLASS TYPE SCHEDULE

1/4" CLEAR, "SAFETY" APPLICATION

1" INSULATED GLASS - OUTDOOR LITE

CLEAR FULLY TEMPERED, INDOOR LIGHT

CLEAR FULLY TEMPERED

1" INSULATED GLASS - OUTDOOR LITE

TINTED FLOAT, INDOOR LIGHT CLEAR

FULLY TEMPERED

1" INSULATED GLASS - OUTDOOR LITE

TINTED FULLY TEMPERED, INDOOR LIGHT

CLEAR LAMINATED FOR BLAST LOADS

DOOR SCHEDULE LEGEND

GLASS TYPE SCHEDULE

G1

G2

G3

G4

2" 2"

2" R

E F

E R

T O

S C

H E

D U

LE

DOOR FRAME

FINISH FLOOR

2"

2"2" R

E F

E R

T O

S C

H E

D U

LE

DOOR FRAME

FINISH FLOOR

1' - 0" 2"

2"

2" R

E F

E R

T O

S C

H E

D U

LE

DOOR FRAME

FINISH FLOOR

2"

KEYED

REMOVABLE

MULLION

G1

NOTE: FOR STOREFRONT

DOOR FRAMES REFER TO A-650

4"

REFER TO

SCHEDULE

REFER

TO SCHEDULE

REFER TO

SCHEDULE

FLUSH DOOR

FLUSH PANEL

DOOR - REFER

TO SCHEDULE

FOR MATERIAL

FULL GLASS

GLASS:

TYPE AS

SCHEDULED

ALUMINUM

STOREFRONT

ENTRANCE

DOOR

F FGOVERHEAD COILINGOH

PREFINISHE

D STEEL

SLATS

3 1/2"

1/

2"

NARROW LITE

GLASS:

TYPE AS

SCHEDULED

NL

3/

4"

FLUSH PANEL

DOOR - REFER

TO SCHEDULE

FOR MATERIAL

6"4"

REFER TO

SCHEDULE

2'

1"

R E

F E

R T

O S

C H

E D

U

LE

REFER

TO SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

REFER

TO SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

REFER

TO SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

DUTCH DOOR

FLUSH PANEL

DOOR - REFER

TO SCHEDULE

FOR MATERIAL

D

REFER

TO SCHEDULE

R E

F E

R T

O S

C H

E D

U

LE

E Q

E Q

DOOR SCHEDULE

DOOR SCHEDULE (SUPPLY WAREHOUSE OLI)

DOOR SCHEDULE (CONFERENCE/BREAK OLI)

D

C

B

A

1 2 3 4 5

Designed:

Drawn :

Checked:

Drawing No.:

Date:

Drawing Title:

Jacobs Project No.:

Scales:

P U

E R

T O

R

IC

O A

R M

Y N

A T

IO

N

A L

G U

A R

D C

A M

P S

A N

T

IA

G O

S A

L

IN

A S

P

U E

R T

O R

IC

O

E N

G

IN

E E

R

IN

G H

O U

S

IN

G

M A

IN

T

E N

A N

C E

S H

O P

E

H M

S

D3250109

DATEREV DESCRIPTION

501 North Broadway, Saint Louis, Missouri 63102

Metro Office Park 17 Street 2, Suite 400, Guaynabo, PR 00968

CH2M HILL‐

HDR JV

BID FINAL 100% DESIGN

B

IM

/U

S P

R T

B D

P

R A

R N

G P

R A

R N

G E

H M

S /P

R A

N G

E H

M S

A rc h .r v t

/7

/2

:4

:5

P

M

A-630RHY

CED

LEV

ARCHITECTURAL

DOOR SCHEDULE

2 JUNE 2023

DOOR

NO.

DOOR FRAME FIRE

RATING HARDWARE REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL

100 FG ALUM 3'-0" X 7'-0" 1 3/4" W2 ALUM D2/A651 B2/A651 D3/A651 12 8

101 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 7

102 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7

103 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7

104 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7

105 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7

106 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3

110 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 10 1, 2, 3

110b F HM 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 8 1, 2, 3

111 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 10 3

112 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 13 1, 2

113 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B2/A631 8 7

114 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B2/A631 9 7

115 F HM PR 6'-0" X 7'-0" 1 3/4" 2 HM D1/A631 C1/A631 B1/A631 45 MIN 6 1, 2

116 F HM PR 6'-0" X 7'-0" 1 3/4" 2 HM D1/A631 C1/A631 B1/A631 6 1, 2

117 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 4 1, 2

118 F HM 3'-6" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

120 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

120b EXIST STL 10'-0" X 10'-0" - - STL D5/A631 C5/A631 B4/A631 11 5

120c NL HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2

121 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 90 MIN 14

122 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

122b OH STL 16'-0" X 14'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4

122c NL HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2

123 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

123b EXIST STL 10'-0" X 10'-0" - - STL - - - 11 5

123c NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2

130 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

130b EXIST STL 10'-0" X 10'-0" - - STL - - - 11 5

130c EXIST STL 10'-0" X 10'-0" - - STL - - - 11 5

130d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

131 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

131b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4

131d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2

132 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

132b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4

132d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2

133 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

133b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4

133d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2

134 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

134b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4

134d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2

135 NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

135b F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

136 NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

1/4" = 1'-0"A1

FRAME TYPES

1/4" = 1'-0"B1

DOOR TYPES

1/4" = 1'-0"

2' 4' 8' 12'

DOOR

NO.

DOOR FRAME FIRE

RATING HARDWARE REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL

140 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

140b OH STL 16'-0" X 14'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4

140c D HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 15 1, 2

140d F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2

141 D HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 15 1, 2

141b NL HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B2/A631 3 7

142 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 8 3, 7

DOOR

NO.

DOOR FRAME FIRE

RATING HARDWARE REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL

150 FG ALUM 3'-0" X 7'-0" 1 3/4" W11 ALUM A3/A631 A4/A631 B1/A631 2

150b FG ALUM 3'-0" X 7'-0" 1 3/4" W10 ALUM A3/A631 A4/A631 B1/A631 2

150c FG ALUM 3'-0" X 7'-0" 1 3/4" W6 ALUM D2/A651 A5/A631 B1/A631 2

151 FG ALUM 3'-0" X 7'-0" 1 3/4" W10 ALUM A3/A631 A4/A631 B1/A631 2

151b FG ALUM 3'-0" X 7'-0" 1 3/4" W11 ALUM A3/A631 A4/A631 B1/A631 2

151c FG ALUM 3'-0" X 7'-0" 1 3/4" W5 ALUM D2/A651 A5/A631 B1/A631 2

1 AMENDMENT 01 03/08/24

File details come from the government source that posted it. Updated .