PRARNG_EHMS_Camp Santiago_DWG A-630_Amendment 01_08-Mar-2024.pdf
PDF 131 KB Posted
- Solicitation number
- W912LR24B0001
- Issued by
-
Department of the Army National Guard
About this file
This file contains an architectural door schedule and details for the PRARNG Engineering Housing and Maintenance Shop project at Camp Santiago Joint Training Center, Salinas, Puerto Rico. The schedule lists over 150 door entries specifying door and frame materials, sizes, ratings, and hardware. Door materials include aluminum, hollow metal, and steel. Frame details are indicated on drawing A-631, and hardware groups are specified separately.
The related federal contract opportunity is solicitation number W912LR24B0001 for construction of the Department of Public Works Engineering Housing and Maintenance Shop building at Camp Santiago Joint Training Center. The contractor will provide all labor, materials, equipment, and incidentals for general construction work as detailed in the statement of work. The awarding agency is the Department of the Army National Guard.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. DOOR DETAILS ARE ON DRAWING A-631 UNLESS OTHERWISE NOTED
2. ALL WOOD DOORS SHALL BE PREFINISHED - REFER TO SPECIFICATIONS
3. ALL STEEL DOORS AND FRAMES SHALL BE PAINTED
4. DO NOT PAINT LABELS OF TESTING AGENCY ON FIRE-RATED DOORS AND FRAMES
5. ALL EXTERIOR STEEL DOORS AND FRAMES SHALL BE GALVANIZED. SOME INTERIOR
DOORS AND FRAMES ARE GALVANIZED. REFER TO DOOR SCHEDULE. WIPE COAT
GALVANIZED STEEL IS NOT ACCEPTABLE.
6. ALL FIRE-RATED DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING
7. FIRE DOORS AND FRAMES SHALL HAVE AN APPROVED LABEL OR LISTING MARK
INDICATING THE FIRE-PROTECTION RATING, WHICH IS PRIMARILY AFFIXED AT THE
FACTORY WHERE FABRICATION AND ASSEMBLY ARE PERFORMED.
8. FIRE-RATED DOOR FRAMES SHALL BE INSTALLED STRICTLY PER MANUFACTURER'S
PRINTED INSTRUCTIONS. MANUFACTURER'S PRINTED INSTRUCTIONS SHALL BE MADE
AVAILABLE TO THE INSPECTION AUTHORITY.
9. ALL EXTERIOR DOORS SHALL BE INSULATED.
10. ALL EXIT DOOR HARDWARE SHALL ALLOW DOORS TO BE OPENED IN THE DIRECTION OF
EXIT WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
11. THE MAXIMUM EXTERIOR DOOR OPENING EFFORTS SHALL NOT EXCEED 8.5 POUNDS.
12. BOTH THE LATCHING AND DEAD BOLT DEVICES ON EXTERIOR DOORS SHALL RELEASE
WITH A SINGLE ACTION OF THE INSIDE LEVER.
13. HINGES FOR OUT-SWINGING EXTERIOR DOORS SHALL BE EQUIPPED WITH NON-
REMOVABLE HINGE PINS IF NOT SCHEDULED TO RECEIVE CONTINUOUS HINGE.
14. REMOVABLE GLAZING STOPS AT BORROW LITES SHALL BE INSTALLED ON SECURE SIDE.
15. DO NOT CAULK BACK BEND STEEL DOOR FRAMES TO GYPSUM BOARD PARTITIONS.
16. THE DOOR FRAME MANUFACTURER SHALL VERIFY ACTUAL WALL / PARTITION THICKNESS
WITH CONTRACTOR PRIOR TO FABRICATION OF DOOR FRAMES.
17. REFER TO SPECIFICATIONS FOR HARDWARE GROUPS.
DOOR SCHEDULE GENERAL NOTES
1. GALVANIZED DOOR AND FRAME
2. INSULATED DOOR
3. UNDERCUT DOOR 3/4" COORDINATE BOTTOM/UNDERCUT OF DOORS WITH FINISH
MATERIALS, THRESHOLDS, ETC.
4. OVERHEAD COILING DOOR SIZE INDICATED IS FOR FINISHED OPENING. ACTUAL DOOR
SIZE WILL BE LARGER BASED ON MANUFACTURER'S STANDARDS.
5. EXISTING OVERHEAD DOOR RELOCATED FROM EXISTING CARPENTRY SHOP (X2),
PLUMBING SHOP, AND ELECTRICAL SHOP. PROTECT DURING DEMOLITION AND
CONSTRUCTION, STORE ON SITE UNTIL INSTALLED. VERIFY DIMENSIONS AND POWER
REQUIREMENTS IN THE FIELD PRIOR TO INSTALLATION.
6. NOT USED
7. PROVIDE COAT HOOK CENTERED ON BACK SIDE OF DOOR AT 5'-6" AFF
8. POWER ASSISTED ENTRANCE DOOR
DOOR SCHEDULE REMARKS
ALUM ALUMINUM
HM HOLLOW METAL
MFR HARDWARE BY DOOR
MANUFACTURER
STL STEEL
WD SOLID CORE WOOD
GLASS TYPE SCHEDULE
1/4" CLEAR, "SAFETY" APPLICATION
1" INSULATED GLASS - OUTDOOR LITE
CLEAR FULLY TEMPERED, INDOOR LIGHT
CLEAR FULLY TEMPERED
1" INSULATED GLASS - OUTDOOR LITE
TINTED FLOAT, INDOOR LIGHT CLEAR
FULLY TEMPERED
1" INSULATED GLASS - OUTDOOR LITE
TINTED FULLY TEMPERED, INDOOR LIGHT
CLEAR LAMINATED FOR BLAST LOADS
DOOR SCHEDULE LEGEND
GLASS TYPE SCHEDULE
G1
G2
G3
G4
2" 2"
2" R
E F
E R
T O
S C
H E
D U
LE
DOOR FRAME
FINISH FLOOR
2"
2"2" R
E F
E R
T O
S C
H E
D U
LE
DOOR FRAME
FINISH FLOOR
1' - 0" 2"
2"
2" R
E F
E R
T O
S C
H E
D U
LE
DOOR FRAME
FINISH FLOOR
2"
KEYED
REMOVABLE
MULLION
G1
NOTE: FOR STOREFRONT
DOOR FRAMES REFER TO A-650
4"
REFER TO
SCHEDULE
REFER
TO SCHEDULE
REFER TO
SCHEDULE
FLUSH DOOR
FLUSH PANEL
DOOR - REFER
TO SCHEDULE
FOR MATERIAL
FULL GLASS
GLASS:
TYPE AS
SCHEDULED
ALUMINUM
STOREFRONT
ENTRANCE
DOOR
F FGOVERHEAD COILINGOH
PREFINISHE
D STEEL
SLATS
3 1/2"
1/
2"
NARROW LITE
GLASS:
TYPE AS
SCHEDULED
NL
3/
4"
FLUSH PANEL
DOOR - REFER
TO SCHEDULE
FOR MATERIAL
6"4"
REFER TO
SCHEDULE
2'
1"
R E
F E
R T
O S
C H
E D
U
LE
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
DUTCH DOOR
FLUSH PANEL
DOOR - REFER
TO SCHEDULE
FOR MATERIAL
D
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
E Q
E Q
DOOR SCHEDULE
DOOR SCHEDULE (SUPPLY WAREHOUSE OLI)
DOOR SCHEDULE (CONFERENCE/BREAK OLI)
D
C
B
A
1 2 3 4 5
Designed:
Drawn :
Checked:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
P U
E R
T O
R
IC
O A
R M
Y N
A T
IO
N
A L
G U
A R
D C
A M
P S
A N
T
IA
G O
S A
L
IN
A S
P
U E
R T
O R
IC
O
E N
G
IN
E E
R
IN
G H
O U
S
IN
G
M A
IN
T
E N
A N
C E
S H
O P
E
H M
S
D3250109
DATEREV DESCRIPTION
501 North Broadway, Saint Louis, Missouri 63102
Metro Office Park 17 Street 2, Suite 400, Guaynabo, PR 00968
CH2M HILL‐
HDR JV
BID FINAL 100% DESIGN
B
IM
/U
S P
R T
B D
P
R A
R N
G P
R A
R N
G E
H M
S /P
R A
N G
E H
M S
A rc h .r v t
/7
/2
:4
:5
P
M
A-630RHY
CED
LEV
ARCHITECTURAL
DOOR SCHEDULE
2 JUNE 2023
DOOR
NO.
DOOR FRAME FIRE
RATING HARDWARE REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL
100 FG ALUM 3'-0" X 7'-0" 1 3/4" W2 ALUM D2/A651 B2/A651 D3/A651 12 8
101 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 7
102 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7
103 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7
104 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7
105 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3 7
106 NL HM TEMPERED 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 3
110 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 10 1, 2, 3
110b F HM 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 8 1, 2, 3
111 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 10 3
112 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 13 1, 2
113 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B2/A631 8 7
114 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B2/A631 9 7
115 F HM PR 6'-0" X 7'-0" 1 3/4" 2 HM D1/A631 C1/A631 B1/A631 45 MIN 6 1, 2
116 F HM PR 6'-0" X 7'-0" 1 3/4" 2 HM D1/A631 C1/A631 B1/A631 6 1, 2
117 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 4 1, 2
118 F HM 3'-6" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
120 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
120b EXIST STL 10'-0" X 10'-0" - - STL D5/A631 C5/A631 B4/A631 11 5
120c NL HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2
121 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 90 MIN 14
122 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
122b OH STL 16'-0" X 14'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4
122c NL HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2
123 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
123b EXIST STL 10'-0" X 10'-0" - - STL - - - 11 5
123c NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2
130 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
130b EXIST STL 10'-0" X 10'-0" - - STL - - - 11 5
130c EXIST STL 10'-0" X 10'-0" - - STL - - - 11 5
130d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
131 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
131b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4
131d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2
132 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
132b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4
132d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2
133 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
133b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4
133d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2
134 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
134b OH STL 10'-0" X 8'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4
134d NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 5 1, 2
135 NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
135b F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
136 NL HM INSULATED 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
1/4" = 1'-0"A1
FRAME TYPES
1/4" = 1'-0"B1
DOOR TYPES
1/4" = 1'-0"
2' 4' 8' 12'
DOOR
NO.
DOOR FRAME FIRE
RATING HARDWARE REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL
140 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
140b OH STL 16'-0" X 14'-0" - - STL D5/A631 C5/A631 B4/A631 1 1, 2, 4
140c D HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 15 1, 2
140d F HM 3'-0" X 7'-0" 1 3/4" 1 HM D1/A631 C1/A631 B1/A631 5 1, 2
141 D HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B1/A631 15 1, 2
141b NL HM 3'-0" X 7'-0" 1 3/4" 1 HM D2/A631 C2/A631 B2/A631 3 7
142 F HM 3'-0" X 7'-0" 1 3/4" 1 HM D4/A631 C4/A631 B2/A631 8 3, 7
DOOR
NO.
DOOR FRAME FIRE
RATING HARDWARE REMARKSTYPE MATERIAL GLAZING SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL
150 FG ALUM 3'-0" X 7'-0" 1 3/4" W11 ALUM A3/A631 A4/A631 B1/A631 2
150b FG ALUM 3'-0" X 7'-0" 1 3/4" W10 ALUM A3/A631 A4/A631 B1/A631 2
150c FG ALUM 3'-0" X 7'-0" 1 3/4" W6 ALUM D2/A651 A5/A631 B1/A631 2
151 FG ALUM 3'-0" X 7'-0" 1 3/4" W10 ALUM A3/A631 A4/A631 B1/A631 2
151b FG ALUM 3'-0" X 7'-0" 1 3/4" W11 ALUM A3/A631 A4/A631 B1/A631 2
151c FG ALUM 3'-0" X 7'-0" 1 3/4" W5 ALUM D2/A651 A5/A631 B1/A631 2
1 AMENDMENT 01 03/08/24