Question_88_-_Reference_OMG_Edge_Box_product_Data.pdf
PDF 676 KB Posted
- Solicitation number
- W912LN-17-B-1001
About this file
Question 88 - Reference OMG Edge Box Data
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Order Specification Form
ANSI/SPRI/FM4435
/ES-1 TESTED
Spines required for box height greater than 6"
Universal fasteners require pre-drilling for masonry applications (min 3/16" pilot hole)
OPTIONAL FINISH STRIP (TYPE 2 SHOWN)
CORRUGATED ROOF
DECK BY OTHERS
ACCESSORY
HEIGHT
BOX WIDTH
MIN: 3-1/2"
MAX: 16"
SPINES, 1" WIDE, 2'-0" O.C.
#14 HD FASTENER SPACED AT 12" F.E. / 48" O.C.
#14 X 1-1/2" UNIVERSAL
FASTENER 6" F.E. / 12" O.C.
TOP SECTION FORMED IN 10'-0" LENGTHS
BOTTOM SECTION 10'-0" LENGTHS
OPTIONAL INSULATION
BY OTHERS
MEMBRANE BY OTHERS
BOX HEIGHT
MIN: 1-1/4"
MAX: 16"
OPTIONAL INSULATION BY OTHERS
QUANTITY MATERIAL ADDITIONAL ACCESSORIES MATERIAL
___ Total LF Mill Galvanized ___ Total LF - Finish strip, Type 1 Mill Galvanized
___ End Caps (___Left, ___Right) ___________ ___ Total LF - Finish strip, Type 2 ___________
___ Total LF - Closure strip DIMENSIONS THICKNESS ___ Height THICKNESS
___ Box Width 20 Ga 20 GA
___ Box Height ___________ ___________
Perimeter Blocking System
FOR RIGID INSULATION
EdgeBox-RI
APPROVALS: Contact manufacturer for verification of test report data on your project. CUSTOMER APPROVAL
Approved for Fabrication Approved with Changes Not Approved
Job Name: Job #: By:
Customer: Project Location: Date:
Representative: Architect: Sheet of
Title Date
Authorized Customer Signature
4 COMMERCE WAY, ARDEN, NC 28704 USA
800.892.9173 828.676.1700 OMGEDGESYSTEMS.COM
Copyright © 2017 OMG, Inc. All rights reserved. EM
Re v.
TOP
SECTION
BOTTOM
SECTION
CLOSURE
(OPTIONAL)
OPTIONAL
INSULATION
(BY OTHERS)
ROOF DECK
(BY OTHERS)
FINISH
STRIP
(OPTIONAL)
END
CAP
COUNTERSUNK HOLES FOR
PROVIDED FASTENERS
PRE-PUNCHED HOLES FOR
PROVIDED FASTENERS
FI
N
IS
H
S
TR
IP
H
EI
G
H T
1 1/2"
BOX WIDTH + 1 1/4"
90°
90°
TYPE 1 FINISH STRIP
1 1/4"
FI
N
IS
H
S
TR
IP
H
EI
G
H T
BOX WIDTH + 1 1/4"
90°
90°
TYPE 2 FINISH STRIP
C
LO
SU
R
E S
TR
IP
H
EI
G H
T
BOX WIDTH + 1 1/4"
90°
CLOSURE STRIP
END CAP
FOR END OF RUN OR OUTSIDE MITER CONDITIONS
Perimeter Blocking System
FOR RIGID INSULATION
EdgeBox-RI
Superior productivity.
Superior performance.