THERMALLY BROKEN
ALUMINUM CURTAINWALL -
SEE WINDOW SCHEDULE
EXISTING WALL
CONSTRUCTION, SEE
STRUCT FOR REINFORCING
2" RIGID INSULATION
AIR SPACE
SOLID SURFACE SILL
TREATED BLOCKING,
ANCHORED TO EXISTING
STRUCTURE AS REQUIRED
AIR BARRIER
PRE-FINISHED BREAK-METAL ALUMINUM
FLASHING (EQUIVALENT TO 20 GA.) W/
CONT. CLEAT FASTENED TO BLOCKING -
COLOR TO MATCH WINDOW SYSTEM - SET
IN CONTINUOUS SEALANT OVER TREATED
WOOD BLOCKING
EXISTING PRECAST
CONCRETE SILL
SPLIT-FACED CMU VENEER
SMOOTH-FACED CMU ACCENT BAND,
CUT ACCENT BAND AS REQUIRED
FOR SILL FLASHING BLOCKING
SILL
CONTINUOUS SEALANT AROUND PERIMETER
W/ BACKER ROD AS REQUIRED, BOTH SIDES
1/2" MAX PLASTIC SHIM
AS REQUIRED
VERIFY
+/- 5"
2"
CONTINUOUS SEALANT
22 GA. STAINLESS STEEL
METAL PAN FLASHING W/ END
DAMS AND DRIP EDGE
WEEPS, MIN. 2 PER WINDOW
VENEER ANCHORS @ 16" O.C.
ATTACHED TO CMU VENEER (GROUTED
CELLS) AND TO EXISTING STRUCTURE
CONTINUOUS SEALANT
ADJUSTABLE WALL TIES
@ 16" O.C. VERTICALLY
AND 24" O.C.
HORIZONTALLY