Question_56_-_Reference_100_AMP_CART.pdf

PDF 123 KB Posted

Attached to
F-35 Alter Bldg 150 MX Hangar Power and Inst. Equip All Spots
Solicitation number
W912LN-17-B-1001
Issued by

About this file

Question 56 - Reverence 100 AMP Cart

View the file

Other files

File Type Posted
Bid_Abstract_of_Offers_W912LN-17-B-1001_Corrected_16_Aug_17.pdf PDF
Bid_Abstract_of_Offers_W912LN-17-B-1001.pdf PDF
Bid_Open_Attendance_Sheet.pdf PDF
B150_Amendment_002_Drawings_July2017.pdf PDF
Amendment_0002_Specifications_03_35_43.pdf PDF
B_150_Amendment_0002.pdf PDF
Question_88_-_Reference_OMG_Edge_Box_product_Data.pdf PDF
B150_Q_&_A_FINAL_24_Jul_17.pdf PDF
Question_88_-_Reference_OMG_Edge_Box.pdf PDF
Wage_Determination_Mod_01.pdf PDF
B150_Q_&_A_as_of_20_Jul_17.pdf PDF
Question_36_-_Reference_Eco-CEP_Epoxy_Primer.pdf PDF
Question_42_-_Reference_A651_Sketch_For_Window_Sill_RFI.pdf PDF
B150_Q_&_A_as_of_18_Jul_17.pdf PDF
Question_59_-_Reference_SD-100_Slab_Areas_Outside_Hanger_Bay.pdf PDF
Question_36_-_Reference__Eco-HPS_100_Urethane_Topcoat.pdf PDF
Question_54_-_Reference_Bldg_150_Sprinker_Spec.pdf PDF
B150_Q_&_A_as_of_14_Jul_17.pdf PDF
Question_30_-_Reference_Sketch_EG101.pdf PDF
Question_60_-_Reference_SD-100_Slab_Areas_Outside_Hanger_Bay.pdf PDF
B150_Q_&_A_as_of_12_Jul_17.pdf PDF
B150_Amendment_0001_Drawings.pdf PDF
B_150_Amendment_0001.pdf PDF
B150_Amendment_0001_-_26_41_00.pdf PDF
B150_Q_&_A_as_of_11_Jul_17.pdf PDF
B150_Q_&_A_as_of_10_Jul_17.pdf PDF
Pre_Bid_Attendance_Sheet.pdf PDF
Pre-Bid_Conference_Minutes_B150.pdf PDF
B-150_Pre-Bid.pdf PDF
F-35_Alter_Bldg_150_MX_B-3_Final_Specs_Vol_2_Apr2017.pdf PDF
F-35_Alter_Bldg_150_MX_B-3_Final_Specs_Vol_1_Apr2017.pdf PDF
W912LN-17-B-1001.pdf PDF
F-35_Alter_Bldg_150_MX_B-3_Final_DWGs_B150_Apr2017.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET OF

M. MARVIN 07/23/09

00/00/00

P. SHULTZ 00/00/00

0000-0000-0000 1 1

Used On 1 Used On 2

Skyko International

USED ON

APPROVED BY

INSPECTED BY

DRAWN BY

FINISH

MATERIAL

S K

Y K

O

IN

TE

R

N A

TI

O

N A

L.

TH

IS

D O

C U

M E

N T

C O

N

TA

IN

S

P R

O P

R

IE

TA

R

Y

IN

FO

R

M A

TI

O

N T

O S

K

YK

O

IN

TE

R

N A

TI

O

N A

L

IT

M A

Y N

O T

B E

R E

P R

O D

U C

E D

, D U

P

LI

C A

TE

D

TR

A N

S

FE

R E

D T

O D

O C

U M

E N

TS

O

R U

S E

D F

O R

M A

N U

FA

C

TU

R

IN

G

O R

A N

Y O

TH

E

R P

U R

P O

S E

S W

IT

H

O U

T P

R

IO

R W

R

IT

TE

N

P E

R M

IS

S

IO

N

O F

ANGLES:

DECIMALS:

.XXX = ±.010

.XX = ±.03

± 2°

TOLERANCES

3. REMOVE ALL BURRS

2. DO NOT SCALE DRAWING

1. DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

TOOL NO:

REV. PART NUMBER

B

SIZE SCALE

DATE

DATE

DATE

LLC

SMART CONTACTOR

7500-2324-GXXX NTS

480 VAC, 60HZ, 3 PHASE WITH RECEPTICAL W/ GROUND FAULT

23.620 11.823

35.433

PART. NO. RUNNING

AMPS

CATASTROPHIC

AMPS

7500-2324-0100

7500-2324-0175

7500-2324-0200

7500-2324-0225

7500-2324-0250

7500-2324-0300

ENCLOSIER OUTSIDE DIMENSIONS

PUNCH INPUT HOLE WHERE

NEEDED. CONNECT WIRES TO

TERMINAL BLOCKS PROVIDED.

SEE DWG.#7500-2324-GXXX.SCH

FOR INTERNAL ENCLOSURE

WIRING.

RECEPTICAL MAY BE ON LEFT OR RIGHT SIDE.

SPECIFY PREFERENCE AND SUPPLY

DRAWINGS WHEN ORDERING.

22.126

MOUNTING HOLES

33.939

MOUNTING HOLES

C2C1 L0

L3 L2

L1

RECEPTICAL

PIN DESIGNATIONS

THIS RECEPTICAL MATES

WITH PLUG #MS27265

ON

TIMER

FAULT

OFF

ON INDICATOR

ON PUSHBUTTON

TIMER INDICATOR

FAULT INDICATOR

OFF PUSHBUTTON

(MUSHROOM E-STOP)

DANGER

HAZARD OF ELECTRICAL

SHOCK OR BURN

DISCONNECT OR TURN OFF POWER

BEFORE SERVICING EQUIPMENT

WARNING

KEEP 5 FEET CLEAR

OF AIRCRAFT ENGINEERING

AND FUEL TANK AREA

AIRCRAFT SAFETY SERVICING

ELECTRICAL SYSTEM

SERIAL NO.

MODEL NO.

SkyKo Intl.

SUPPLY

VOLTS AMPS FREQ

PHASES SCCR RATING = 100kA

ALL MODELS HAVE A 100KA SCCR RATING.

00/00/00

P. SHULTZ 00/00/00

0000-0000-0000 1 1

Used On 1 Used On 2

Skyko International

USED ON

APPROVED BY

INSPECTED BY

DRAWN BY

FINISH

MATERIAL

S K

Y K

O

IN

TE

R

N A

TI

O

N A

L.

TH

IS

D O

C U

M E

N T

C O

N

TA

IN

S

P R

O P

R

IE

TA

R

Y

IN

FO

R

M A

TI

O

N T

O S

K

YK

O

IN

TE

R

N A

TI

O

N A

L

IT

M A

Y N

O T

B E

R E

P R

O D

U C

E D

, D U

P

LI

C A

TE

D

TR

A N

S

FE

R E

D T

O D

O C

U M

E N

TS

O

R U

S E

D F

O R

M A

N U

FA

C

TU

R

IN

G

O R

A N

Y O

TH

E

R P

U R

P O

S E

S W

IT

H

O U

T P

R

IO

R W

R

IT

TE

N

P E

R M

IS

S

IO

N

O F

ANGLES:

DECIMALS:

.XXX = ±.010

.XX = ±.03

± 2°

TOLERANCES

3. REMOVE ALL BURRS

2. DO NOT SCALE DRAWING

1. DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

TOOL NO:

REV. PART NUMBER

B

SIZE SCALE

DATE

DATE

DATE

LLC

SMART CONTACTOR

7500-2324-GXXX NTS

480 VAC, 60HZ, 3 PHASE WITH RECEPTICAL W/ GROUND FAULT

23.620 11.823

35.433

PART. NO. RUNNING

AMPS

CATASTROPHIC

AMPS

7500-2324-0100

7500-2324-0175

7500-2324-0200

7500-2324-0225

7500-2324-0250

7500-2324-0300

ENCLOSIER OUTSIDE DIMENSIONS

PUNCH INPUT HOLE WHERE

NEEDED. CONNECT WIRES TO

TERMINAL BLOCKS PROVIDED.

SEE DWG.#7500-2324-GXXX.SCH

FOR INTERNAL ENCLOSURE

WIRING.

RECEPTICAL MAY BE ON LEFT OR RIGHT SIDE.

SPECIFY PREFERENCE AND SUPPLY

DRAWINGS WHEN ORDERING.

22.126

MOUNTING HOLES

33.939

MOUNTING HOLES

C2C1 L0

L3 L2

L1

RECEPTICAL

PIN DESIGNATIONS

THIS RECEPTICAL MATES

WITH PLUG #MS27265

MOUNTING HOLES

3/8 BOLTS 4 TYP.

COMPONENT PLATE AND MOUNTING HOLE DIMENSIONS

REMOTE STATION

INDICATOR AND PUSHBUTTON

TERMINATION BLOCKS.

XLE

A B C

W D

U -1

W

D U

-1

P R

O O

VIN

G

C

IR

C U

IT

W D

U -1

W

D U

-1

W D

U -1

W D

U -1

W

D U

-1

W D

U -1

W D

U -1

W D

U -1

W

D U

-1

R E

M . E

N A

BLE

FIR

E

STO

P

R E

M . C

O M

M O

N

R E

M . O

N

IN

D

R E

M . O

N B

U

TTO

N

R E

M

. TIM

ER

IN

D

R E

M . O

FF B

U

TTO

N

R E

M . O

FF IN

D

R

E M

. P A

N

EL C

O M

F3

5 AMP

GND

24VDC

POWER

SUPPLY

F1

2 AMP

F2

2 AMP

F1

2 AMP

F2

2 AMP

F3

5 AMP

F3

5 AMP

G R

O U

N D

FA

U

LT

M

O D

U

LE

00/00/00

P. SHULTZ 00/00/00

0000-0000-0000 1 1

Used On 1 Used On 2

Skyko International

USED ON

APPROVED BY

INSPECTED BY

DRAWN BY

FINISH

MATERIAL

S K

Y K

O

IN

TE

R

N A

TI

O

N A

L.

TH

IS

D O

C U

M E

N T

C O

N

TA

IN

S

P R

O P

R

IE

TA

R

Y

IN

FO

R

M A

TI

O

N T

O S

K

YK

O

IN

TE

R

N A

TI

O

N A

L

IT

M A

Y N

O T

B E

R E

P R

O D

U C

E D

, D U

P

LI

C A

TE

D

TR

A N

S

FE

R E

D T

O D

O C

U M

E N

TS

O

R U

S E

D F

O R

M A

N U

FA

C

TU

R

IN

G

O R

A N

Y O

TH

E

R P

U R

P O

S E

S W

IT

H

O U

T P

R

IO

R W

R

IT

TE

N

P E

R M

IS

S

IO

N

O F

ANGLES:

DECIMALS:

.XXX = ±.010

.XX = ±.03

± 2°

TOLERANCES

3. REMOVE ALL BURRS

2. DO NOT SCALE DRAWING

1. DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

TOOL NO:

REV. PART NUMBER

B

SIZE SCALE

DATE

DATE

DATE

LLC

SMART CONTACTOR

7500-2323-GXXX NTS

480 VAC, 60HZ, 3 PHASE NO RECEPTICAL W/ GROUND FAULT

23.620

11.823

35.433

PART. NO. RUNNING

AMPS

CATASTROPHIC

AMPS

7500-2323-0100

7500-2323-0175

7500-2323-0200

7500-2323-0225

7500-2323-0250

7500-2323-0300

LINE IN MAY ENTER

FROM TOP OR SIDE.

PLEASE PROVIED PREFERENCE

SO THAT INTERNAL BLOCKS

MAY BE PLACED APPROPRIATELY.

ENCLOSIER OUTSIDE DIMENSIONS

PUNCH OUTPUT HOLE WHERE

NEEDED.

CONNECT WIRES TO TERMINAL

BLOCKS PROVIDED.

SEE DWG.#7500-2323-GXXX.SCH

FOR INTERNAL ENCLOSURE

WIRING.

22.126

33.939

MOUNTING HOLES.

MOUNTING HOLES.

ALL MODELS HAVE A 100KA SCCR RATING.

ON INDICATOR

ON PUSHBUTTON

TIMER INDICATOR

FAULT INDICATOR

OFF PUSHBUTTON

(MUSHROOM E-STOP)

DANGER

HAZARD OF ELECTRICAL

SHOCK OR BURN

DISCONNECT OR TURN OFF POWER

BEFORE SERVICING EQUIPMENT

WARNING

KEEP 5 FEET CLEAR

OF AIRCRAFT ENGINEERING

AND FUEL TANK AREA

AIRCRAFT SAFETY SERVICING

ELECTRICAL SYSTEM

SERIAL NO.

MODEL NO.

SkyKo Intl.

SUPPLY

VOLTS AMPS FREQ

PHASES SCCR RATING = 100kA

ON

TIMER

FAULT

OFF

00/00/00

P. SHULTZ 00/00/00

0000-0000-0000 1 1

Used On 1 Used On 2

Skyko International

USED ON

APPROVED BY

INSPECTED BY

DRAWN BY

FINISH

MATERIAL

S K

Y K

O

IN

TE

R

N A

TI

O

N A

L.

TH

IS

D O

C U

M E

N T

C O

N

TA

IN

S

P R

O P

R

IE

TA

R

Y

IN

FO

R

M A

TI

O

N T

O S

K

YK

O

IN

TE

R

N A

TI

O

N A

L

IT

M A

Y N

O T

B E

R E

P R

O D

U C

E D

, D U

P

LI

C A

TE

D

TR

A N

S

FE

R E

D T

O D

O C

U M

E N

TS

O

R U

S E

D F

O R

M A

N U

FA

C

TU

R

IN

G

O R

A N

Y O

TH

E

R P

U R

P O

S E

S W

IT

H

O U

T P

R

IO

R W

R

IT

TE

N

P E

R M

IS

S

IO

N

O F

ANGLES:

DECIMALS:

.XXX = ±.010

.XX = ±.03

± 2°

TOLERANCES

3. REMOVE ALL BURRS

2. DO NOT SCALE DRAWING

1. DIMENSIONS ARE IN INCHES

UNLESS OTHERWISE SPECIFIED

TOOL NO:

REV. PART NUMBER

B

SIZE SCALE

DATE

DATE

DATE

LLC

SMART CONTACTOR

7500-2323-GXXX NTS

480 VAC, 60HZ, 3 PHASE NO RECEPTICAL W/ GROUND FAULT

23.620

11.823

35.433

PART. NO. RUNNING

AMPS

CATASTROPHIC

AMPS

7500-2323-0100

7500-2323-0175

7500-2323-0200

7500-2323-0225

7500-2323-0250

7500-2323-0300

LINE IN MAY ENTER

FROM TOP OR SIDE.

PLEASE PROVIED PREFERENCE

SO THAT INTERNAL BLOCKS

MAY BE PLACED APPROPRIATELY.

ENCLOSIER OUTSIDE DIMENSIONS

PUNCH OUTPUT HOLE WHERE

NEEDED.

CONNECT WIRES TO TERMINAL

BLOCKS PROVIDED.

SEE DWG.#7500-2323-GXXX.SCH

FOR INTERNAL ENCLOSURE

WIRING.

22.126

33.939

MOUNTING HOLES.

MOUNTING HOLES.

ALL MODELS HAVE A 100KA SCCR RATING.

MOUNTING HOLES

3/8 BOLTS 4 TYP.

22.126

COMPONENT PLATE AND MOUNTING HOLE DIMENSIONS

REMOTE STATION

INDICATOR AND PUSHBUTTON

TERMINATION BLOCKS.

XLE

A B C

W D

U -1

W

D U

-1

P R

O O

VIN

G

C

IR

C U

IT

W D

U -1

W

D U

-1

W D

U -1

W D

U -1

W

D U

-1

W D

U -1

W D

U -1

W D

U -1

W

D U

-1

R E

M . E

N A

BLE

FIR

E

STO

P

R E

M . C

O M

M O

N

R E

M . O

N

IN

D

R E

M . O

N B

U

TTO

N

R E

M

. TIM

ER

IN

D

R E

M . O

FF B

U

TTO

N

R E

M . O

FF IN

D

R

E M

. P A

N

EL C

O M

F3

5 AMP

GND

24VDC

POWER

SUPPLY

F1

2 AMP

F2

2 AMP

F1

2 AMP

F2

2 AMP

F3

5 AMP

F3

5 AMP

G R

O U

N D

FA

U

LT

M

O D

U

LE

OUTPUT TO LOAD

LINE IN

7500-2323-0XXX SCH
7500-2323-GXXX 36_24_12 TOP BOT_GE CONT_COMP
7500-2323-GXXX 36_24_12 TOP BOT_GE CONT_OUTSIDE
7500-2324-0XXX 36_24_12 IN TOP_REC_GE CONT_COMP
7500-2324-0XXX 36_24_12 IN TOP_REC_GE CONT_OUTSIDE
7500-2324-0XXX SCH
7500-2324-GXXX 36_24_12 ALL BOTTOM REC LEFT_GE CONT
7500-2324-GXXX 36_24_12 ALL BOTTOM REC LEFT_GE CONT_OUTSIDE
7500-2324-GXXX 36_24_12 ALL BOTTOM REC RIGHT_GE CONT_COMP
7500-2324-GXXX 36_24_12 ALL BOTTOM REC RIGHT_GE CONT_OUTSIDE
7500-2325-0XXX SCH
ALTECH PSH-120 24VDC 5A HIGH 370-550 V IN
BENDER RCM420 GROUND FAULT MONITOR
Binder1
ALTECH PSH-120 24VDC 5A HIGH 370-550 V IN
BENDER RCM420 GROUND FAULT MONITOR
BURNDY LUGS
BUSSMANN power block spec sheet
CE_Declaration_of_Conformity_OCS_series
CH SERIES MODULAR FUSE HOLDERS
Declarat..._of_Conformity_OCS_series
Ferrule spec
FNQ-R BUSSMANN LOW VOLTAGE BRANCH CIRCUIT FUSE
SAFETY SERVICE SYSTEMS COMPONENT LISTING
xltdatasheet
BURNDY LUGS
BUSSMANN power block spec sheet
CE_Declaration_of_Conformity_OCS_series
CH SERIES MODULAR FUSE HOLDERS
Declarat..._of_Conformity_OCS_series
Ferrule spec
FNQ-R BUSSMANN LOW VOLTAGE BRANCH CIRCUIT FUSE
xltdatasheet

File details come from the government source that posted it. Updated .