Question_88_-_Reference_OMG_Edge_Box.pdf

PDF 962 KB Posted

Attached to
F-35 Alter Bldg 150 MX Hangar Power and Inst. Equip All Spots
Solicitation number
W912LN-17-B-1001
Issued by

About this file

Question 88 - Reference OMG Edge Box

View the file

Other files

File Type Posted
Bid_Abstract_of_Offers_W912LN-17-B-1001_Corrected_16_Aug_17.pdf PDF
Bid_Abstract_of_Offers_W912LN-17-B-1001.pdf PDF
Bid_Open_Attendance_Sheet.pdf PDF
B150_Amendment_002_Drawings_July2017.pdf PDF
Amendment_0002_Specifications_03_35_43.pdf PDF
B_150_Amendment_0002.pdf PDF
Question_88_-_Reference_OMG_Edge_Box_product_Data.pdf PDF
B150_Q_&_A_FINAL_24_Jul_17.pdf PDF
Wage_Determination_Mod_01.pdf PDF
B150_Q_&_A_as_of_20_Jul_17.pdf PDF
Question_56_-_Reference_100_AMP_CART.pdf PDF
Question_36_-_Reference_Eco-CEP_Epoxy_Primer.pdf PDF
Question_42_-_Reference_A651_Sketch_For_Window_Sill_RFI.pdf PDF
B150_Q_&_A_as_of_18_Jul_17.pdf PDF
Question_59_-_Reference_SD-100_Slab_Areas_Outside_Hanger_Bay.pdf PDF
Question_36_-_Reference__Eco-HPS_100_Urethane_Topcoat.pdf PDF
Question_54_-_Reference_Bldg_150_Sprinker_Spec.pdf PDF
B150_Q_&_A_as_of_14_Jul_17.pdf PDF
Question_30_-_Reference_Sketch_EG101.pdf PDF
Question_60_-_Reference_SD-100_Slab_Areas_Outside_Hanger_Bay.pdf PDF
B150_Q_&_A_as_of_12_Jul_17.pdf PDF
B150_Amendment_0001_Drawings.pdf PDF
B_150_Amendment_0001.pdf PDF
B150_Amendment_0001_-_26_41_00.pdf PDF
B150_Q_&_A_as_of_11_Jul_17.pdf PDF
B150_Q_&_A_as_of_10_Jul_17.pdf PDF
Pre_Bid_Attendance_Sheet.pdf PDF
Pre-Bid_Conference_Minutes_B150.pdf PDF
B-150_Pre-Bid.pdf PDF
F-35_Alter_Bldg_150_MX_B-3_Final_Specs_Vol_2_Apr2017.pdf PDF
F-35_Alter_Bldg_150_MX_B-3_Final_Specs_Vol_1_Apr2017.pdf PDF
W912LN-17-B-1001.pdf PDF
F-35_Alter_Bldg_150_MX_B-3_Final_DWGs_B150_Apr2017.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P R O D U C T D A T A S P E C I F I C A T I O N S

PRODUCT DESCRIPTION

EdgeBox RI is an innovative new product that is an engineered metal replacement system for roof nailers.

FEATURES & BENEFITS

• Replaces traditional wood blocking or nailers at the perimeter of a low-slope roof . Eliminates concerns about fastener corrosion in ACQ treated wood. No rotting, insect damage or mold.

• Provides a retainer for rigid insulation. Maintains high R-value designed to prevent thermal loss from system.

• Includes pre-punched holes and supplied corrosion-resitant fasteners for proper attachment and fast installation.

Spines required for box height greater than 6"

Universal fasteners require pre-drilling for masonry applications (min 3/16" pilot hole)

OPTIONAL FINISH STRIP (TYPE 2 SHOWN)

CORRUGATED ROOF

DECK BY OTHERS

ACCESSORY

HIEGHT

BOX WIDTH

MIN: 3-1/2"

MAX: 16"

SPINES, 1" WIDE, 2'-0" O.C.

#14 HD FASTENER SPACED AT 12" F.E. / 48" O.C.

#14 X 1-1/2" UNIVERSAL

FASTENER 6" F.E. / 12" O.C.

TOP SECTION FORMED IN 10'-0" LENGTHS

BOTTOM SECTION 10'-0" LENGTHS

OPTIONAL INSULATION

BY OTHERS

MEMBRANE BY OTHERS

BOX HEIGHT

MIN: 1-1/4"

MAX: 16"

OPTIONAL INSULATION BY OTHERS

Perimeter Metal Blocking System

G. Finish Strip Parallel to deck flutes

(required for metal deck) H. Closure Strip

Perpendicular to deck flutes (required for metal deck)

Installation Guide for EdgeBox-RI

FINISH STRIP

(TYPE 2 SHOWN)

CORRUGATED ROOF

DECK BY OTHERS

CONCEALED

JOINT SPLICE

#14 HD FASTENER

12" F.E. / 48" O.C.

#14 X 1½" UNIVERSAL FASTENER

6" F.E. / 12" O.C. (TYP. 4)

TOP SECTION

10’ LENGTHS

BOTTOM SECTION 10' LENGTHS

OPTIONAL INSULATION

BY OTHERS

MEMBRANE BY OTHERS

B. Bottom Section 10-ft. Lengths

A. Top Section 10-ft. Lengths

C. End Cap Insert Slides into exposed end of bottom section

D. #14 X 1½-in. Universal Fastener Included and required

F. EdgeBox Spine Required for face greater than 6-in.

E. #14 HD Roofing Fastener Size varies based on height of EdgeBox min. 1-in. penetration required

A

B

F

OPTIONAL

INSULATION

(BY OTHERS)

ROOF DECK

(BY OTHERS)

G

C

E

D

F

CLOSURE STRIP

FASTENER

PROVIDED

NOTES:

#1 - Isolate all metal parts from ACQ treated wood or other galvanically incompatible material with appropriate membrane material.

#2 - Appliance attachments, such as lightning rods, signs, or antennae that penetrate the water seal, induce a galvanic reaction, or otherwise compromise the effectiveness of the roof edge system, shall be eliminated or isolated to prevent problems per section 8.0 of ANSI/SPRI/FM4435/ES-1. Appliances shall be isolated from or not attached to the roof edge system. Consult the lightning protection system manufacturer for specific attachment instructions.

ANSI/SPRI/FM4435

/ES-1 TESTED

APPROVALS: Contact manufacturer for verification of test report data on your project.

Height Width Material

1.25 - 6-in. 3.5 - 6-in.

20 Ga.

Galvanized Steel Box

6.25 - 12-in.

20 Ga.

Galvanized Box w/ 20 Ga. Spine

12.25 - 16-in.

20 Ga.

Galvanized Box w/ 16 Ga. Spine

SPECIFICATIONS (short form) The perimeter blocking shall be the EdgeBox RI as manufactured by the OMG EdgeSystems. The EdgeBox two-piece assembly shall be fabricated from 20 Ga. galvanized steel with pre- punched fastener holes. The bottom section is attached to the metal deck with the provided mechanical fasteners. No slots are necessary for use with rigid insulation. Installation shall conform to Manufacturer’s written instructions.

DESCRIPTION

Application

EdgeBox is an innovative new product that is an engineered metal replacement system for roof nailers. The two-piece design replaces traditional wood blocking or nailers at the perimeter of a low-slope roof. EdgeBox attaches to the roof deck and is used in conjunction with OMG fascia profiles that have been tested to meet the ANSI/SPRI/FM4435/ES-1 roof edge standard, now required by the International Building Code.

INSTALLATION PROCEDURES

This is a general outline. Refer to our full installation guide for details.

Preparation:

The substrate should be flat and level from front to back. Shim areas not level.

Procedure:

Starting at the corners, install a closure strip at the end of the metal deck closing off the flutes and a finish strip parallel with the flutes provid-ing a level surface for EdgeBox. Fasten bottom sections of the blocking to the metal deck using the provided fasteners leaving an 1/8-in. gap for expansion. Slide end cap inserts into exposed ends of bottom section. Starting at the corners, place top section onto bottom section, secure each end with the supplied fasteners into holes provided.

FINISH

Natural mill galvanized steel

GUARANTEE

Manufacturer’s Standard Warranty:

Materials shall be free of defects in material and workmanship for five years after ship-ment. If, after inspection, the manufacturer agrees that the materials supplied by them are defective, the manufacturer shall at their option repair or replace them.

TECHNICAL SERVICES

Engineering and shop drawings are available from the factory. Product samples and detail sheets are ready for your submittal package.

For personal assistance with questions or submittals, contact your local OMG EdgeSys-tems representative.

I N S T A L L A T I O N P R O C E D U R E

EM

Re v.

4 COMMERCE WAY, ARDEN, NC 28704 USA

800.892.9173 828.676.1700 OMGEDGESYSTEMS.COM

Copyright © 2017 OMG, Inc. All rights reserved. PermaSnap is a trademark of OMG, Inc.

Superior productivity.

Superior performance.

Perimeter Metal Blocking System

File details come from the government source that posted it. Updated .