ECIP_Phase_1_addendum_003.pdf

PDF 1 MB Posted

Attached to
ECIP:SOLAR PV ARRAYS PHASE I (KNMD119002) AND ECIP:SOLAR PV ARRAYS PHASE II (KNMD119003)
Solicitation number
W912J6-14-R-0002
Issued by

About this file

ECIP Phase I Addendum 0003

View the file

Other files

File Type Posted
Q A_Dated_14AUG2014.pdf PDF
W912J614R0002-0010.pdf PDF
Q A_Dated_13AUG2014_0600_hrs.pdf PDF
W912J614R0002-0009.pdf PDF
EXHIBITDW912J614R0002REVISED.doc DOC document
Q A_Dated_12AUG2014_1030_hrs.pdf PDF
REV_00010_BID_SCHEDULE_01AUG14.pdf PDF
Q A_Dated_11AUG2014_1300_hrs.pdf PDF
Q A_Dated_11AUG2014_0800_hrs.pdf PDF
63826-E601R1.pdf PDF
W912J614R0002-0008.pdf PDF
63826-E002R1.pdf PDF
KNMD119003_C-101-R3.pdf PDF
Q A_Dated_08AUG2014_0700_hrs.pdf PDF
W912J614R0002-0007.pdf PDF
Q A_Dated_06AUG2014_0700hrs.pdf PDF
HICK-SPV-481413.ECIP_1.pdf PDF
Q A_Dated_04AUG2014.pdf PDF
ECIP_Phase_2_addendum_003.pdf PDF
HICK-SPV-481413.ECIP_2.pdf PDF
W912J614R0002-0006.pdf PDF
REV_00010_BID_SCHEDULE_01AUG14.pdf PDF
W912J614R0002-0005.pdf PDF
W912J614R0002-0004.pdf PDF
EXHIBITGTEPCalcW912J614R0002REVISED.pdf PDF
Q A_Dated_01AUG2014.pdf PDF
W912J614R0002-0003.pdf PDF
JBPHHINST_5510.1_-_JBPHH_Base_Access_Regulation_22Sep11.pdf PDF
HICK-SPV-316229.ECIP_1.pdf PDF
ECIP_Phase_1_Addendum_002.pdf PDF
ECIP_Phase_2_Addendum_002.pdf PDF
HICK-SPV-316229.ECIP_2.pdf PDF
Q A_Dated_29JUL2014.pdf PDF
Q A_Dated_28JUL2014.pdf PDF
HICK-SPV-013100.ECIP_1.pdf PDF
HICK-SPV-013100.ECIP_2.pdf PDF
ECIP_I_Addendum_1.pdf PDF
HICK-SPV-013300.ECIP_1.pdf PDF
W912J614R0002-0002.pdf PDF
EXHIBITEW912J614R0002_REVISED.doc DOC document
HICK-SPV-013300.ECIP_2.pdf PDF
EXHIBITCW912J614R0002REVISED.doc DOC document
ECIP_II_Addendum_1.pdf PDF
Q A_Dated_25JUL2014.pdf PDF
W912J614R0002-Preproposal_Site_Visit_Minutes_22_Jul_14.pdf PDF
Pre-Proposal_Meeting_Attendance_Sheet_22Jul14.pdf PDF
Q A_Dated_22JUL2014.pdf PDF
Q A_Dated_14JUL2014.pdf PDF
Q A_Dated_11JUL2014.pdf PDF
W912J614R0002-0001.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

U x

E U x

E U x

E U x

E U x

E U x

E U x

E

U x

E

U x

E

U x

E x

E x

E x

E x

E x

E x

E x

E x

E x

AGE

BUILDING

EXISTING

PARKING

E 1,657,286.82

N 55,394.65

E 1,657,332.47

MATCH EXISTING

FENCE

N 55,680.20

E 1,657,235.63

N 55,639.97

E 1,657,241.69

N 55,709.31

E 1,657,123.87

N 55,719.62

.5 m

[1 .0

A C

C E

S S

D R

IV

E

E 1,657,269.12

N 55,186.36

BUILDING 2324

E 1,657,170.22

N 55,389.79

E 1,657,170.22

N 55,195.02

E 1,657,186.47

N 55,208.65

E 1,657,170.35

4.00' PERSONNEL GATE

N 55,337.43 m

A

C

C

E

S

D

R

I V

E

E 1,657,307.52

N 55,377.78

BATTERY

SELFRIDGE

EXISTING

F22 SQUAD

OPS HANGER

E 1,657,323.80

N 55,667.56

.5 m

[1 .0

G R

A V

E L A

C C

E S

S

D R

IV

E

CONTROL PANEL SLAB

(6' X 4') TOC = 5.50

SEE ELECTRICAL

DRAWINGS

E 1,657,293.78

N 55,254.39

UE UE

U E

U

E

E 1,657,096.89

N 55,411.26

EXISTING

PARKING LOT

E 1,657,307.73

N 55,633.67

E 1,657,251.88

N 55,653.61

E 1,657,257.94

N 55,722.95

E 1,657,323.80

N 55,647.32

E 1,657,110.23

N 55,735.87

E 1,657,323.80

N 55,381.44

CONNECT TO

EXISTING FENCE

E 1,657,080.64

N 55,397.63

E 1,657,202.08

N 55,387.00

UE

E

C

U C

HH2G

E

E

E

E

UC

C

UE

U E

U

E

U

E

UE

UC

E

UC

E

U

E

U

C

1. ALL WEED CONTROL FABRIC AND CRUSHED ROCK GROUND COVER TO

BE INCLUDED IN PHASE I OF THE ECIP PROJECT FOR THE ENTIRE

PHASE I AND II PV ARRAY FIELD INCLUDING ALL OPTION AREAS.

COORDINATE INSTALLATION SEQUENCE WITH AWARDED OPTIONS IN

PHASE I AND PHASE II DRAWINGS. SEE NOTE 11, C-101.

2. ALL ELECTRICAL WORK BETWEEN THE LIMITS OF THE PV ARRAY

GOING WEST AND IN FRONT OF THE SQUAD OPS HANGAR SHALL BE

COMPLETED TO MINIMIZE IMPACTS ON BUILDING ACCESS AND SHALL

BE DONE IN TIMELY AND EFFICIENT MANNER. THE PHASING OF THE

CONSTRUCTION SHALL MAINTAIN CONTINUOUS SAFE BUILDING

ACCESS DURING ALL WORK AND LIMIT THE DURATION TO COMPLETE

WORK IN FRONT OF OR WITHIN THE FINISHED LANDSCAPED AREA

NEAR SQUAD OPS TO A MAXIMUM OF 10 CALENDAR DAYS. ALL

DAMAGED HARDSCAPE ELEMENTS SHALL BE RESTORED TO MATCH

EXISTING MATERIALS AND JOINTING. AT LEAST ONE SIDEWALK

BETWEEN THE PARKING LOT AND SQUAD OPS HANGAR SHALL REMAIN

OPEN AT ALL TIMES. ALL DISTURBED LANDSCAPING, PLANTING,

IRRIGATION SYSTEMS, GRASS/TURF AREAS SHALL BE RESTORED TO

PRE-CONTRACT CONDITIONS. ALL PLANTINGS SHALL MATCH EXISTING

ITEMS IN SIZE AND TYPE. ALL GRASS TYPES SHALL MATCH EXISTING

GRASSES. CONTRACTOR SHALL MAINTAIN ALL DISTURBED AREAS

INCLUDING WEEDING, FERTILIZER AND MONITORING OF IRRIGATION

UNTIL NEW PLANTINGS AND GRASS ARE FULLY RE-ESTABLISHED.

CONTRACTOR SHALL SUBMIT IN HIS EXECUTION PLAN SKETCHES

IDENTIFYING ALL AREAS THAT WILL BE DISTURBED BY HIS ACTIONS

AND IDENTIFY MATERIALS, PLANTS, ETC. THAT WILL BE USED TO

REPLACE OR REPAIR AREAS. THIS PLAN SHALL BE APPROVED BY THE

CONTRACTING OFFICER PRIOR TO BEGINNING ANY WORK.

3. CONCRETE MOW STRIP TO BE 12" WIDE BY 12" DEEP WITH 4-#5 BARS

LONGITUDINALLY.

S c a l e

F o r

M i c r o f i l m i n g

I n c h e s

M i l l i m e t e r s

191 1615141312111098765432 17 18

N

M

L

K

J

I

H

G

F

E

D

C

B

A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

C O

P Y

R I G

H T

B

U R

N

A

M c D

O N

N E

L L

E

N G

I N

E E

R I N

G

C

O M

P A

N Y

I N

C

C

HAWAII AIR NATIONAL GUARD

JOINT BASE PEARL HARBOR HICKAM

OAHU, HAWAII

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

68326

Project No. - KNMD119002

JANUARY 2014

01/24/14

RTA SUBMITTAL

FOR REVIEW

0 MZ

W90FYQ-09-D-0002

ECIP SOLAR PV ARRAYS,

PHASE I

KNMD119002C-102.DWG

D. MUETING

R. BARUTH

MATCH

EXISTING

FENCE

PV FIELD SITE PLAN

F

H

A N

G A

R

EXISTING

FENCE

EXISTING

FENCE

M

A

M

A

L

B

Y

R

I V

E

EXISTING

RMAG

PHASE 1 PV ARRAYS SEE DRAWING E-002

BASE BID

PIER T.O.C. ELEV. 5.00

BID OPTION 1

PIER T.O.C. ELEV. 4.50

BID OPTION 2

PIER T.O.C. ELEV. 4.00

PH II PV ARRAY

COVER THE GROUND AREA WITH 6" LAYER OF OPEN

GRADED 2" BROWN/TAN COLOR CRUSHED ROCK ON

WEED CONTROL FABRIC AFTER INSTALLATION OF

FOUNDATIONS (TYP)

24' X 4'

EQUIPMENT

SLAB TOC = 6.00

SEE ELECTRICAL

DRAWINGS

4' X 50'

EQUIPMENT

SLAB SEE

ELECTRICAL

DRAWINGS

MANHOLE

COORDINATE NEW

ELECTRICAL WITH

EXISTING UTILITIES.

SEE NOTE 2.

SECURITY

FENCE WITH

CONCRETE

MOW STRIP

HANDHOLE

PV SITE PLAN NOTES:

PHASE II PV

ARRAYS

SEE NOTE 1

HANDHOLE

SEE ELECTRICAL

DRAWINGS

SEE DRAWING E-002

FOR SITE ELECTRICAL

SEE NOTE 2.

EXISTING TRANSFORMER

CONCRETE MOW STRIP

(12" WIDE, 12" DEEP)

SEE NOTE 3

12" WIDE BY 12" DEEP CONCRETE MOW STRIP

AROUND PERIMETER OF ROCK SURFACE. SEE

DETAIL 2, C-500.

12" MOW STRIP AROUND

ENTIRE PERIMETER. SEE

NOTE 3.

12" MOW STRIP

SEE NOTE 3.

12" MOW STRIP SEE NOTE 3.

COVER AREA WITH

4" TOP SOIL SEEDING AND

TEMPORARY IRRIGATION AFTER

DEMOLITION OF ENTRANCE

DRIVE

SEE NOTE 2

4.57m [15.00']

ACCESS DRIVE

EXISTING

UNDERGROUND

COMMUNICATIONS

LINE

1 07/28/14 ADDENDUM 002 MZ

2 07/30/14 ADDENDUM 003 MZ

8+009+00

F

M

E 1654577.46

INSTALL PV PIER

T.O.C. = 7.50 (TYP)

N 55167.96

E 1654578.96

INSTALL PV PIER

T.O.C. = 7.50 (TYP)

N 55293.96

E 1654455.96

PV PIER

T.O.C. = 7.50 (TYP)

N 55293.96

E 1654469.46

INSTALL PV PIER

T.O.C. = 7.50 (TYP)

N 55167.96

U

C

U

E

U

E

UE

UE

U E

U E

U E

U

E

U

C

C

U E

U

C

U

C

HB

HB

HBHB

HD

HD

HD

HD

HD

HDHD

HB

8+009+00

F

M

ELECTRICAL SLAB

152mm [6"] GRANULAR

FILL

SEE STRUCTURAL DRAWINGS FOR

FOUNDATION INFORMATION

PRECAST CONCRETE CAP

m m

BOND BEAM - SEE

STRUCT.

TOP OF BRICK

EL = 33.32m [109'-4"]

FINISH FLOOR

ARCH EL = 30.48m [100'-0"]

CIVIL = 5.50'

EXPANSION JOINT

BETWEEN WALL AND

CONCRETE

B3

203mm [8"]

SPLIT-FACED CMU

m m

102mm [4"] X 203mm [8"]

SMOOTH-FACED CMU

102mm [4"] X 203mm [8"]

SMOOTH-FACED CMU

m m m m m m

229mm [9"]

114mm

[4 1/2"]

19.mm [3/4"] 19mm [3/4"]SCREENWALL

THICKNESS

114mm

[4 1/2"]

CONTINUOUS DRIP

EACH SIDE

CMU VENEER

DOWELS

CMU WALL

KNMD119002C-103.DWG

D. MUETING

R. BARUTH D. LENZ

OVERALL CIVIL SITE PLAN

NOTES:

LEGEND

CONCRETE

SIDEWALK

1. ALL COORDINATES AND DIMENSIONS ARE TO EXTERIOR CORNER OF BUILDING SLAB, FACE OF CURB, OR EDGE OF PAVEMENT AND ARE IN FEET UNLESS NOTED OTHERWISE..

2. CONTRACTOR SHALL REINFORCE ALL CONCRETE SLABS THAT HAVE MANHOLES, CLEANOUTS,

GUARD POSTS, OR ARE IRREGULAR IN SHAPE AS INDICATED OR AS DIRECTED BY CONTRACTING

OFFICER.

3. CONTRACTOR TO FIELD VERIFY LOCATION, SIZE, BOLT PATTERN, AND ELEVATION OF CONCRETE

PIERS PRIOR TO SUBMITTING SHOP DRAWINGS AND STEEL FABRICATION.

4. CONTRACTOR SHALL PLACE PROTECTION FOR ALL PAVEMENTS AND EXISTING NEW FINISHES PRIOR

TO BEGINNING ANY CONSTRUCTION OF ECIP COVERED PARKING IN FRONT OF THE F-22 SIMULATOR

FACILITY. THERE SHALL BE NO DRIVING OF EQUIPMENT ON CONCRETE FINISHES - MUST PLACE

PROTECTION FIRST SUCH AS PLYWOOD OVER THE AREA OF PROJECT WORK. NO SCOOPING OF

SOILS OR FOUNDATION BORING MATERIALS WITH A BOBCAT SHALL BE DONE DIRECTLY ON THE

SURFACE OF THE CONCRETE SIDEWALKS OR PAVEMENTS UNLESS COMPLETELY COVERED WITH

DURABLE MATERIALS FOR PROTECTION. ALL WORK DIRECTLY ON SIDEWALKS SHALL BE DONE BY

HAND SHOVELING AND THE SURFACES SHALL BE SWEPT CLEAN ON A DAILY BASIS. CONTRACTOR

SHALL MAKE A FULL ASSESSMENT OF THE EXISTING CONDITIONS AT THE START OF CONSTRUCTION

FOR ESTABLISHING THE BASE LINE AND THEN DOCUMENT WHAT WILL BE CONSIDERED DAMAGE OR

DAMAGED ITEMS BY THIS CONTRACT WORK. CONTRACTOR SHALL WALK THE AREA OF PROPOSED

CONSTRUCTION WITH THE CONTRACTING OFFICER AND PHOTOGRAPH/DOCUMENT ALL AREAS FOR

EXISTING SITE CONDITIONS. ANY DAMAGE TO CONCRETE SIDEWALKS OR PARKING LOT PAVEMENTS

SHALL BE REPLACED FULL DEPTH IN COMPLETE PANELS. SAWCUT THE PERIMETER OF THE

EXISTING PANEL FULL DEPTH, REMOVE THE PAVEMENT WITHOUT DAMAGING ADJACENT PANELS,

INSTALL REQUIRED DOWELS AND REBAR AND PLACE NEW CONCRETE WITH JOINTS AND SEALANTS

TO MATCH EXISTING SITE CONDITIONS. IT IS CRITICAL THAT THE RECENTLY CONSTRUCTED

PARKING LOT AND NEW SIMULATOR FINISHES NOT BE DAMAGED IN ANY WAY WHILE EXECUTING THE

ECIP PROJECT. ALL REPAIRS AND METHODS SHALL BE APPROVED IN WRITING PRIOR TO BEGINNING

ANY WORK..

5. CONTRACTOR SHALL SCHEDULE AND EXECUTE THE WORK TO MINIMIZE IMPACT TO THE

GOVERNMENT USE OF THE NEWLY CONSTRUCTED PARKING LOT. THE PARKING LOT SHALL NOT BE

COMPLETELY CLOSED FOR ANY DURATION OF THE WORK. THE INSTALLATION OF THE SUNSHADES

AND STRUCTURES SHALL BE DONE TO KEEP AT LEAST ONE ROW OF PARKING OPEN AT ALL TIMES

FOR USE BY THE BUILDING OCCUPANTS. IF THE ENTIRE LOT MUST ME CLOSED IT SHALL BE LIMITED

TO ONLY 5 WORKING DAYS AND SHALL NOT OCCUR MORE THAN THREE TIMES DURING THE ENTIRE

INSTALLATION OF THE PV SUNSHADES IN THE SIMULATOR BUILDING PARKING LOT. BUILDING

ACCESS SHALL NOT BE BLOCKED AT ANY TIME DURING THE CONSTRUCTION ACTIVITIES. THE JOB

SITE SHALL BE KEPT CLEAN AND WELL ORGANIZED. NO LANDSCAPING OR UNPAVED AREAS

AROUND THE PARKING LOT SHALL BE DAMAGED EXCEPT FOR THE INSTALLATION OF CONDUITS OR

CABLING. ALL DISTURBED AREAS SHALL BE RESTORED TO THEIR EXISTING CONDITIONS INCLUDING

PLANTINGS, SEEDING, SODDING, AND IRRIGATION. ALL PLANTINGS SHALL MATCH EXISTING

PLANTINGS IN SIZE AND TYPE.

INSTALL

NEW SIDEWALK

S c a l e

F o r

M i c r o f i l m i n g

I n c h e s

M i l l i m e t e r s

191 1615141312111098765432 17 18

N

M

L

K

J

I

H

G

F

E

D

C

B

A date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

C O

P Y

R I G

H T

B

U R

M c D

O N

N E

L L

E

N G

I N

E E

R I N

G

C

O M

P A

N Y

I N

C

C

HAWAII AIR NATIONAL GUARD

JOINT BASE PEARL HARBOR HICKAM

OAHU, HAWAII

KANSAS CITY, MISSOURI

ENGINEERS ARCHITECTS & CONSULTANTS

68326

Project No. - KNMD119002

JANUARY 2014

01/24/14

RTA SUBMITTAL

FOR REVIEW

0 MZ

W90FYQ-09-D-0002

ECIP SOLAR PV ARRAYS,

PHASE I

I:\USNGB\52085\CAD\CIVIL\ECIP\SHEETS\KNMD119002C-103.DWG 7/30/2014 1:44 PM D_MUETING

5.00'(TYP)

PARKING LOT PV SYSTEM

(SEE SHEET S-005)

6.00'

INSTALL

NEW SIDEWALK

AROUND PV

PIERS

121.00'

18.00' (TYP)

18.00' (TYP)

INSTALL PV PIERS (TYP) FILL IN

SIDEWALK CONCRETE AROUND

NEW PV PIER COLUMNS (TYP)

EXISTING SIMULATOR PARKING

LOT (SEE NOTES 5, 6)

EXISTING PV PIERS

(TYP 5)

EXISTING PV PIERS

(TYP 5)

SEE NOTE 3.

INSTALL

PV PIERS (TYP 15)

INSTALL SCREEN WALL

AROUND ELECTRICAL

EQUIPMENT.

C

SCALE IN FEET

2' 4'

ECIP ENCLOSURE WALL SECTION

SECTION C

TYPICAL PRECAST CONCRETE

CAP AT SCREEN WALL

SECTION 2

ELECTRICAL EQUIPMENT SLAB

INSIDE WALLS AREA.

10.00'

1 07/30/14 ADDENDUM 003 MZ

KNMD119002 C-102-R2
KNMD119002 C-103-R1